For focused group profiling of human cytokine receptor-related gene expression

Size: px
Start display at page:

Download "For focused group profiling of human cytokine receptor-related gene expression"

Transcription

1 GeneCopoeia TM Expressway to Discovery Product Data Sheet ExProfile TM Human Cytokine Receptor Related Gene qpcr Array For focused group profiling of human cytokine receptor-related gene expression Cat. No. QG008-A (1 x 96-well plate, Format A) Cat. No. QG008-B (1 x 96-well plate, Format B) Cat. No. QG008-C (1 x 96-well plate, Format C) Cat. No. QG008-D (1 x 96-well plate, Format D) Cat. No. QG008-E (1 x 96-well plate, Format E) Plates available individually or as a set of 6. Each plate contains 84 unique gene primer pairs deposited in one 96-well plate. Introduction The ExProfile human cytokine receptor related gene qpcr array profiles the expression of 84 human genes related to the function and mechanism of cytokine receptors. These genes are carefully chosen for their close pathway correlation based on a thorough literature search of peer-reviewed publications. This array allows researchers to study pathway-related genes to gain understanding of their roles in the function and mechanism of cytokine receptors. QG008 plate 01: 84 unique gene PCR primer pairs Shipping and storage conditions Shipped at room temperature Stable for at least 6 months when stored at -20 C Array format GeneCopoeia provides five qpcr array formats (A, B, C, D, and E) suitable for use with the following realtime cyclers. Important note: Upon receipt, please check to make sure that the correct array format was ordered to ensure compatibility with your qpcr instrument. Plate format Instrument provider qpcr instrument model A B C D E Applied Biosystems Applied Biosystems Bio-Rad Laboratories Bio-Rad Laboratories Roche Applied Science 5700, 7000, 7300, 7500, 7700, 7900HT (Standard 96-well block), ViiA TM 7 (Standard 96-well block) 7500 (Fast block), 7900HT (Fast block), StepOnePlus TM, ViiA TM 7(Fastblock) icycler iq,myiq,iq 5 CFX96, DNA Engine Opticon, DNA Engine Opticon 2, Chromo4 LightCycler 480 (96-well block) 1

2 Quality control 1. Each pair of primers in the ExProfile gene qpcr array has been experimentally validated to yield a single dissociation curve peak and to generate a single amplicon of the correct size for the targeted gene. 2. The positive PCR controls (PCR) have been verified to amplify a single amplicon of the correct size with Ct values around 20±2. 3. The Spike-in reverse transcription controls (RT) have been verified to amplify a single amplicon of the correct size with Ct values around 20±3. 4. R 2 > 0.99 was observed for high inter/ intra-array reproducibility. Materials required but not provided All-in-One TM First-Strand cdna Synthesis Kit All-in-One TM qpcr Mix Total RNA extraction kit (RNAzol RT RNA extraction reagent is recommended) DNase/RNase free tips, PCR reaction tubes, 1.5 ml microcentrifuge tubes 5 ml and 10 ml graduated pipettes, beakers, flasks, and cylinders 10 μl to1,000μl adjustable single channel micropipettes with disposable tips 5 μl to20μl adjustable multichannel micropipette, disposable tips, and reservoir qpcr instrument, compatible with gene qpcr arrays ordered Array layout Figure1. Illustration of QG008 plate 01 Gene primer pairs: 84 wells (A row to G row) are designated for a real-time PCR assay for genes (see the primer list). HK1-6: Six pre-deposited housekeeping gene (HK1-6) primer pairs, which can be used as endogenous positive controls as well as for array normalization. GDC: Genomic DNA controls, which can be used to specifically detect genomic DNA contamination with a high level of sensitivity. RT: Spike-in reverse transcription controls, which can be used to monitor the efficiency of the RT reactions. These pre-deposited primer pairs specifically amplify the cdna template reverse transcribed from the spike-in control RNA in the sample. PCR: Positive PCR controls, which are used to verify the PCR efficiency by amplifying the predeposited DNA template with its specific pre-deposited primer pairs. 2

3 Gene primer list Plate Position Catalog No. of Primer Accession No. of Gene Symbol QG A01 HQP NM_ AGTRL1 QG A02 HQP NM_ FAS QG A03 HQP NM_ TNFRSF17 QG A04 HQP NM_ BLR1 QG A05 HQP NM_ CD27 QG A06 HQP NM_ TNFRSF8 QG A07 HQP NM_ CD40 QG A08 HQP NM_ CHUK QG A09 HQP NM_ CCR1 QG A10 HQP NM_ CCR5 QG A11 HQP NM_ CCR6 QG A12 HQP NM_ CCR7 QG B01 HQP NM_ CCR8 QG B02 HQP NM_ CMKLR1 QG B03 HQP NM_ CX3CR1 QG B04 HQP NM_ DIAPH2 QG B05 HQP NM_ EGFR QG B06 HQP NM_ EPOR QG B07 HQP NM_ DARC QG B08 HQP NM_ CCR10 QG B09 HQP NM_ CXCR3 QG B10 HQP NM_ GPR31 QG B11 HQP NM_ IFNAR1 QG B12 HQP NM_ IFNAR2 QG C01 HQP NM_ IFNGR1 QG C02 HQP NM_ IFNGR2 QG C03 HQP NM_ IGF1R QG C04 HQP NM_ IGF2R QG C05 HQP NM_ IL1R1 QG C06 HQP NM_ IL1RAP QG C07 HQP NM_ IL2RA QG C08 HQP NM_ IL2RB QG C09 HQP NM_ IL2RG QG C10 HQP NM_ IL3RA QG C11 HQP NM_ IL4R QG C12 HQP NM_ IL5RA QG D01 HQP NM_ IL6R QG D02 HQP NM_ IL6ST QG D03 HQP NM_ IL7R QG D04 HQP NM_ IL8RA QG D05 HQP NM_ IL8RB 3

4 4 Product Data Sheet QG D06 HQP NM_ IL9R QG D07 HQP NM_ IL10RA QG D08 HQP NM_ IL10RB QG D09 HQP NM_ IL11RA QG D10 HQP NM_ IL12RB1 QG D11 HQP NM_ IL12RB2 QG D12 HQP NM_ IL13RA1 QG E01 HQP NM_ IL13RA2 QG E02 HQP NM_ IL15RA QG E03 HQP NM_ TNFRSF9 QG E04 HQP NM_ TNFRSF11B QG E05 HQP NM_ PDGFRA QG E06 HQP NM_ PDGFRL QG E07 HQP NM_ PDGFRB QG E08 HQP NM_ TLR2 QG E09 HQP NM_ TLR4 QG E10 HQP NM_ TNFRSF1A QG E11 HQP NM_ TNFRSF1B QG E12 HQP NM_ IL1R2 QG F01 HQP NM_ CXCR4 QG F02 HQP NM_ SOCS1 QG F03 HQP NM_ TNFRSF14 QG F04 HQP NM_ TNFRSF18 QG F05 HQP NM_ TNFRSF11A QG F06 HQP NM_ TNFRSF10D QG F07 HQP NM_ TNFRSF10C QG F08 HQP NM_ TNFRSF10B QG F09 HQP NM_ TNFRSF10A QG F10 HQP NM_ IL18RAP QG F11 HQP NM_ IL1RL2 QG F12 HQP NM_ SOCS2 QG G01 HQP NM_ SOCS3 QG G02 HQP NM_ CCRL2 QG G03 HQP NM_ IL1RL1 QG G04 HQP NM_ IL27RA QG G05 HQP NM_ SOCS5 QG G06 HQP NM_ EBI3 QG G07 HQP NM_ CXCR6 QG G08 HQP NM_ CCR9 QG G09 HQP NM_ CCR3 QG G10 HQP NM_ LTB4R QG G11 HQP NM_ FGFR1 QG G12 HQP NM_ TNFRSF4 QG H01 HGDC QG H02 HGDC QG H03 HQP NM_ GAPDH QG H04 HQP NM_ ACTB

5 QG H05 HQP NM_ B2M QG H06 HQP NM_ RPL13A QG H07 HQP NM_ HPRT1 QG H08 HQP NR_ RN18S1 QG H09 RT QG H10 RT QG H11 PCR QG H12 PCR 5

6 Limited Use License Following terms and conditions apply to use of ExProfile TM Human Cytokine Receptor Related Gene qpcr Array (the Product). If the terms and conditions are not acceptable, the Product in its entirety must be returned to GeneCopoeia within 5 calendar days. A limited End-User license is granted to the purchaser of the Product. The Product shall be used by the purchaser for internal research purposes only. The Product is expressly not designed, intended, or warranted for use in humans or for therapeutic or diagnostic use. The Product must not be resold, repackaged or modified for resale, or used to manufacture commercial products or deliver information obtained in service without prior written consent from GeneCopoeia. This Product should be used in accordance with the NIH guidelines developed for recombinant DNA and genetic research. Use of any part of the Product constitutes acceptance of the above terms. Limited Warranty GeneCopoeia warrants that the Product meets the specifications described in the accompanying Product Datasheet. If it is proven to the satisfaction of GeneCopoeia that the Product fails to meet these specifications, GeneCopoeia will replace the Product. In the event a replacement cannot be provided, GeneCopoeia will provide the purchaser with a refund. This limited warranty shall not extend to anyone other than the original purchaser of the Product. Notice of nonconforming products must be made to GeneCopoeia within 30 days of receipt of the Product. GeneCopoeia s liability is expressly limited to replacement of Product or a refund limited to the actual purchase price. GeneCopoeia s liability does not extend to any damages arising from use or improper use of the Product, or losses associated with the use of additional materials or reagents. This limited warranty is the sole and exclusive warranty. GeneCopoeia does not provide any other warranties of any kind, expressed or implied, including the merchantability or fitness of the Product for a particular purpose. GeneCopoeia is committed to providing our customers with high-quality products. If you should have any questions or concerns about any GeneCopoeia products, please contact us at GeneCopoeia, Inc. GeneCopoeia, Inc Medical Center Drive, Suite 101 Rockville, MD (301) (866) inquiry@genecopoeia.com GeneCopoeia Products are for Research Use Only Copyright 2016 GeneCopoeia, Inc. Trademarks: GeneCopoeia, ExProfile, All-in-One, (GeneCopoeia Inc.); RNAzol RT (Molecular Research Center, Inc.); SYBR (Molecular Probes); icycler iq, MyiQ, iq 5, CFX96, DNA Engine Opticon, DNA Engine Opticon 2, Chromo4 (Bio-Rad); LightCycler (Roche);Trizol, ABI,ROX,ViiA TM,StepOnePlus TM (Life Technologies). QG