1 Bioindicators and Hygiene monitoring sample material for Cleaning and Disinfection Technical informations: +49-(0) Orders: Fax: +49-(0)

2 1. Hygiene Controls Contact samples (RODAC) for aerobe total germ count, enriched medium with disinhibitor substances Contact samples (RODAC) for aerobe total germ count, enriched medium with disinhibitor substances, 3-times packed and γ-irradiated Container for water samples, sterile, 500 ml, with sodium thiosulfate for inactivation of chorine 2. Bioindicators for washing procedures (DesVali W) DesVali W1 5 cotton lobules (1 cm 2 ), soiled with defibrinated sheep blood, germ concentration > 10 7 cfu/lobule DesVali W2 For each germ 5 cotton lobules (1 cm 2 ), soiled with defibrinated sheep blood, germ concentration > 10 7 cfu/lobule (bacteria) and > 10 6 cfu/lobule (C. albicans) germs: Enterococcus hirae ATCC Staphylococcus aureus ATCC 6538 Escherichia coli K12 NCTC Candida albicans ATCC DesVali W3 For each germ 5 cotton lobules (1 cm 2 ), soiled with defibrinated sheep blood, germ concentration > 10 7 cfu/lobule germs: Enterococcus faecium ATCC 6057 Staphylococcus aureus ATCC 6538 DesVali W4 For each allergen 5 cotton lobules (1 cm 2 ), contaminated with bovine serum albumine, allergen concentration > 2500 ng/lobule allergens: Der f 1, major allergen from house dust mite (Dermatophagoides farinae) Fel d 1, major allergen from cat (Felis catus domesticus)

3 3. Bioindicators for dish washing procedures (DesVali G) DesVali G1 According DIN 10510:2008 and DIN 10512:2008, stainless steel germ carrier soiled with bovine albumin, mucine and maize starch, germ concentration > 10 7 cfu/germ carrier Accessories: Germ carrier holder acc. DIN 10510:2008 Germ carrier holder acc. DIN 10512: Bioindicators for the reprocessing of cages from the animal farming (DesVali K) DesVali K1 According to AK-KAB:2010, stainless steel carrier for evaluation of cleaning effects, soiled with proteins, cellulose and germ oil including methyl red DesVali K2 According to AK-KAB:2010, stainless steel germ carrier for evaluation of the decontamination, soiled with defibrinated sheep blood, germ concentration > 10 7 cfu/carrier 5. Bioindicators for the reprocessing of medical devices (DesVali R) DesVali R1 According ISO annex G, screws, soiled with defibrinated sheep blood, semolina or egg yolk, germ concentration > 10 8 cfu/screw DesVali R2 According ISO annex G, gum tubes (6 mm inner diameter), soiled with defibrinated sheep blood, semolina or egg yolk, germ concentration > 10 7 cfu/tube DesVali R3 According ISO annex A/M/N, Crile clamp soiled with defibrinated sheep blood (without bacteria) DesVali R4 According ISO annex A/M/N, Crile clamp soiled with defibrinated sheep blood, germ concentration > 10 7 cfu/clamp

4 DesVali R5 According DIN and AK-BWA:2005, stainless steel germ carrier for evaluation of decontamination, soiled with defibrinated sheep blood, germ concentration > 10 7 cfu/carrier DesVali R6 According ISO annex H, stainless steel germ carrier for evaluation of cleaning and disinfection effects, contamination with bovine albumin, mucine and maize starch, germ concentration > > 10 7 cfu/carrier DesVali R7 According ISO annex I, PTFE tubes (1 mm inner diameter) for evaluation of the cleaning, soiled with heparinised sheep blood (without bacteria) DesVali R8 According ISO annex I, PTFE tubes (1 mm inner diameter) for evaluation of cleaning and disinfection, contamination with heparinised sheep blood, germ concentration > 10 9 cfu/tube DesVali R9 According ISO annex I, PTFE tubes (2 mm inner diameter) for evaluation of the cleaning, contamination with heparinised sheep blood (without bacteria) DesVali R10 According ISO annex I, PTFE tubes (2 mm inner diameter) for evaluation of cleaning and disinfection, contamination with heparinised sheep blood, germ concentration > 10 9 cfu/tube 6. Miscellaneous Temperature logger for monitoring the temperature in aqueous cleaning procedures

5 Purchase order form Orders can be placed per Fax: +49-(0) or via Company / name Contact person Street PLZ + location Telefone -address number Name of product / description price Specialoffer price Thank you for shopping our products. Terms and conditions apply ( You accept the general terms and conditions with your signature. Date: Signature: