2

3 Disclaimer The information that is presented in this report reflects the conditions that were observed in the building(s) during the time frame this inspection was conducted. Although every effort was made to identify the potential suspect building materials and components, there is no guarantee that additional building materials in these damaged buildings are not present. Conditions may exist in the building(s), such that inaccessible materials may only become apparent during demolition activities. If any hidden, suspicious material is encountered, it is recommended that the material be analyzed to confirm its asbestos content.

4 FIGURES

5

6 TABLES

7 TABLE 1 ASBESTOS SURVEY MATERIAL SUMMARY PARCEL MORRIS LANE, ANDERSON, SOUTH CAROLINA Homogeneous Material Number Material Type Material Description Material Locations Friable Sample Numbers Sample Results Sample Locations Asbestos- Containing Material Approximate Quantity of Asbestos Condition of Material 01 Wall & White, with Rooms 1-8 No SC-H18-01A None Detected Room 1 Ceiling Board White Joint Compound SC-H18-01B None Detected Room 2 No Not Applicable Not Applicable SC-H18-01C None Detected Room 6 02 Stucco White, on Ceiling Rooms 1-8 No SC-H18-02A None Detected Room 1 Board SC-H18-02B None Detected Room 2 No Not Applicable Not Applicable SC-H18-02C None Detected Room 6 03 Vinyl Floor Yellow Pattern Rooms 1, 2, and No SC-H18-03A 10% Chrysotile Room 1 Yes 150 Square Feet Damaged Sheeting and with Yellow 7 Floor Adhesive SC-H18-03B Not Analyzed Room 2 Adhesive SC-H18-03C Not Analyzed Room 7 04 Asphaltic Gray Shingles Exterior Roof No SC-H18-04A None Detected Exterior Roof No Not Applicable Not Applicable Roofing Material SC-H18-04B None Detected Exterior Roof SC-H18-04C None Detected Exterior Roof According to EPA, asbestos-containing material (ACM) is defined as any material containing greater than 1% asbestos using laboratory analysis or, by NESHAP, contains less than 10% asbestos is considered positive, unless re-analyzed by PLM point count.

8 TABLE 2 PAINT SURVEY SUMMARY PARCEL MORRIS LANE, ANDERSON, SOUTH CAROLINA Component Locations Color Substrate Condition Findings Recommendations All painted components Interior and Exterior All Paint Colors All Substrates All Conditions All paint contains at least a trace of lead and must be addressed according to OSHA requirements for lead-containing paint. If impacted by renovation/demolition activities, proper handling and/or removal of the lead-containing paint is needed. * The requirements of the Occupational Safety and Health Administration (OSHA) Construction Standards need to be invoked if any metal content is present in the paint that may be affected by renovation activities. OSHA does not provide a minimum concentration criteria level for lead; however, it requires precautions and protection for workers and the working environment be taken at any work place where an exposure to airborne metals may occur.

9 TABLE 3 WASTE SAMPLING VIA TCLP PARCEL MORRIS LANE, ANDERSON, SOUTH CAROLINA Material Type Test Type Material Description Sample Numbers Sample Results Hazardous or Non-Hazardous Anticipated Waste Debris from Facility TCLP (lead) Building components SC-H18-TCLP < Non-Hazardous According to the EPA, TCLP criteria limit for leachable lead is defined as 5 milligrams per liter (mg/l) using laboratory analysis.

10 ATTACHMENT A

11 EMSL Analytical, Inc. 200 Route 130 North Cinnaminson, NJ Tel/Fax: (800) / (856) / cinnasblab@emsl.com EMSL Order: Customer ID: BAKE51 Customer PO: Project ID: Attention: Gary Case Phone: (412) Michael Baker, Jr. Inc. Fax: (412) Airside Drive Received Date: 09/10/2018 8:55 AM Moon Township, PA Analysis Date: 09/24/ /25/2018 Project: Anderson House 18 Collected Date: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Sample Description Appearance % Fibrous % Non-Fibrous SC-H18-01A SC-H18-01B SC-H18-02A SC-H18-02B SC-H18-03A SC-H18-03B White Fibrous Homogeneous Brown/White Fibrous Homogeneous White Fibrous Homogeneous Brown/White Fibrous Homogeneous Tan Fibrous Homogeneous 10% Cellulose 5% Min. Wool 15% Cellulose 10% Cellulose 5% Glass 15% Cellulose 5% Cellulose 85% Non-fibrous (Other) 85% Non-fibrous (Other) 85% Non-fibrous (Other) 85% Non-fibrous (Other) 85% Non-fibrous (Other) Asbestos % Type None Detected None Detected None Detected None Detected 10% Chrysotile Positive Stop (Not Analyzed) SC-H18-04A Black Fibrous Homogeneous 15% Glass 85% Non-fibrous (Other) None Detected SC-H18-04B Black Fibrous Homogeneous 15% Glass 85% Non-fibrous (Other) None Detected Analyst(s) Daniel Fricker (3) Ebony Miller (4) Benjamin Ellis, Laboratory Manager or Other Approved Signatory EMSL maintains liability limited to cost of analysis. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M "Interim Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. All samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. EMSL recommends gravimetric reduction for all non-friable organically bound materials prior to analysis. Estimation of uncertainty is available on request. Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NVLAP Lab Code , AIHA-LAP, LLC-IHLAP Lab , NYS ELAP 10872, NJ DEP 03036, PA ID# Initial report from: 09/25/ :13:05 ASB_PLM_0008_ Printed: 9/25/2018 8:20 AM Page 1 of 1

12 EMSL Analytical, Inc CastlePlace Dr., Indianapolis, IN Phone/Fax: (317) / (317) indianapolislab@emsl.com EMSL Order: CustomerID: CustomerPO: ProjectID: BAKE51 Attn: Gary Case Michael Baker, Jr. Inc. 100 Airside Drive Moon Township, PA Phone: (412) Fax: (412) Received: 09/13/18 8:00 AM Collected: Project: Anderson Houses Test Report: Toxicity Characteristic Leachate Procedure (1311/7000B) Client SampleDescription Collected Analyzed RDL Lead Concentration SC - H1 - TCLP < SC - H2 - TCLP < SC - H3 - TCLP < SC - H4 - TCLP < SC - H5 - TCLP < SC - H6 - TCLP < SC - H7 - TCLP < SC - H8 - TCLP < SC - H9 - TCLP < SC - H10 - TCLP < SC - H11 - TCLP < Doug Wiegand, Laboratory Manager or other approved signatory This report relates only to those items tested. Samples received in good condition unless otherwise noted. Quality Control Data associated with this sample set is within acceptable limits, unless otherwise noted Samples analyzed by EMSL Analytical, Inc. Indianapolis, IN Initial report from 0 18:17:38 Test Report PB w/rdl Printed: 6:17:38 PM Page 1 of 2

13 EMSL Analytical, Inc CastlePlace Dr., Indianapolis, IN Phone/Fax: (317) / (317) indianapolislab@emsl.com EMSL Order: CustomerID: CustomerPO: ProjectID: BAKE51 Attn: Gary Case Michael Baker, Jr. Inc. 100 Airside Drive Moon Township, PA Phone: (412) Fax: (412) Received: 09/13/18 8:00 AM Collected: Project: Anderson Houses Test Report: Toxicity Characteristic Leachate Procedure (1311/7000B) Client SampleDescription Collected Analyzed RDL Lead Concentration SC - H12 - TCLP < SC - H13 - TCLP < SC - H14 - TCLP < SC - H15 - TCLP < SC - H16 - TCLP < SC - H17 - TCLP < SC - H18 - TCLP < Doug Wiegand, Laboratory Manager or other approved signatory This report relates only to those items tested. Samples received in good condition unless otherwise noted. Quality Control Data associated with this sample set is within acceptable limits, unless otherwise noted Samples analyzed by EMSL Analytical, Inc. Indianapolis, IN Initial report from 0 18:17:38 Test Report PB w/rdl Printed: 6:17:38 PM Page 2 of 2

14 ATTACHMENT B

15 MICHAEL BAKER INTERNATIONAL, INC. PHOTOGRAPHIC RECORD PARCEL IDENTIFICATION: Parcel PHOTOGRAPH L Street PHOTOGRAPHS BY Michael Baker Comments: Front of house PHOTOGRAPH L Street PHOTOGRAPHS BY Michael Baker Comments: Material #03 Vinyl Floor Sheeting (Yellow Pattern)

16 ATTACHMENT C

17

18

19 August 31, 2016 Laboratory ID: Oommen Kappil EMSL Analytical, Inc. 200 Route 130 North Cinnaminson, NJ Dear Mr. Kappil: Congratulations! The AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC s Analytical Accreditation Board (AAB) has approved EMSL Analytical, Inc. as an accredited Industrial Hygiene, Environmental Lead and Environmental Microbiology laboratory. Accreditation documentation includes the IHLAP, ELLAP and EMLAP accreditation certificate, scope of accreditation document and a copy of the current AIHA-LAP, LLC license agreement (if your completed agreement is not on file at AIHA-LAP, LLC). The accreditation symbol has been designed for use by all AIHA-LAP, LLC accredited laboratories. If your laboratory chooses to use the symbol in its advertising the laboratory s accreditation, you must complete and return the AIHA-LAP, LLC license agreement to a Laboratory Accreditation Specialist. Once submitted, an electronic copy of the accreditation symbol will be sent to you. Please inform us if your laboratory does not wish to use the symbol in advertising. Laboratory accreditation shall be maintained by continued compliance with IHLAP, ELLAP and EMLAP requirements (see Policy Modules 2B, 2C, 2D, and 6), which includes proficient participation in AIHA-LAP, LLC approved proficiency testing, demonstration of competency, or round robin program as indicated on the AIHA-LAP Approved PT and Round Robin webpage, its associated Scope/PT table, and as required in Policy Module 6, for all Fields of Testing (FoTs) for which the laboratory is accredited. An accredited laboratory that wishes to expand into a new FoT must submit an updated accreditation application to AIHA-LAP, LLC for review by the AAB. Any changes in ownership, laboratory location, personnel, FoTs/Methods, or significant procedural changes shall be reported to AIHA-LAP, LLC in writing within twenty (20) business days of the change. The accreditation certificate is the property of AIHA-LAP, LLC and must be returned to us should your laboratory withdraw or be removed from the IHLAP, ELLAP and EMLAP. Again, congratulations. If you have any questions, please contact Lauren Schnack, Laboratory Accreditation Specialist, at (703) Sincerely, Cheryl O. Morton Managing Director AIHA Laboratory Accreditation Programs, LLC AIHA Laboratory Accreditation Programs, LLC 3141 Fairview Park Drive, Suite 777, Falls Church, VA USA main fax R3 05/05/2015 Page 1 of 1

20 AIHA Laboratory Accreditation Programs, LLC acknowledges that EMSL Analytical, Inc. 200 Route 130 North, Cinnaminson, NJ Laboratory ID: along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2005 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following: LABORATORY ACCREDITATION PROGRAMS INDUSTRIAL HYGIENE Accreditation Expires: September 01, 2018 ENVIRONMENTAL LEAD Accreditation Expires: September 01, 2018 ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: September 01, 2018 FOOD Accreditation Expires: UNIQUE SCOPES Accreditation Expires: Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2005 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA- LAP, LLC website ( for the most current Scope. William Walsh, CIH Chairperson, Analytical Accreditation Board Cheryl O. Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC Revision 15: 03/30/2016 Date Issued: 08/31/2016

21 AIHA Laboratory Accreditation Programs, LLC SCOPE OF ACCREDITATION EMSL Analytical, Inc. Laboratory ID: Route 130 North, Cinnaminson, NJ Issue Date: 10/20/2016 The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory s current accreditation status for the particular field(s) of testing/methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation. Industrial Hygiene Laboratory Accreditation Program (IHLAP) Initial Accreditation Date: 02/01/1989 IHLAP Scope Category Chromatography Core Field of Testing (FoT) (FoTs cover all relevant IH matrices) Effective: 04/10/ _Scope_IHLAP (Method Addition)_2016_10_20 Page 1 of 2 Technology sub-type/ Detector Published Reference Method/Title of Inhouse Method NIOSH 1003 Modified NIOSH 1005 NIOSH 1400 Modified GC/FID NIOSH 1500 Modified NIOSH 1501 Modified Gas Chromatography NIOSH 1550 Modified NIOSH 1603 Modified NIOSH 2000 Modified NIOSH 5502 Modified GC/ECD NIOSH 5503 Modified NIOSH 5510 Modified OSHA 1010 Modified GC/MS GC/MS EPA TO-15 Gas Chromatography (Diffusive Samplers) NIOSH 1501 Modified Ion Chromatography (IC) NIOSH 6004 Modified NIOSH 6011 NIOSH 7903 OSHA ID-165SG OSHA ID-214 OSHA ID-215 Modified Liquid Chromatography HPLC/FL NIOSH 2016 Modified HPLC/UV NIOSH 5506 Modified NIOSH 6009 Modified OSHA ID-140 Modified OSHA ID-145 Spectrometry Core Atomic Absorption CVAA Method Description or Analyte (for internal methods only)

22 IHLAP Scope Category Spectrometry Core Asbestos/Fiber Microscopy Core Miscellaneous Core Beryllium Testing Field of Testing (FoT) (FoTs cover all relevant IH matrices) Atomic Absorption Inductively-Coupled Plasma X-ray Diffraction (XRD) UV/VIS (Colorimetric) Polarized Light Microscopy (PLM) Phase Contrast Microscopy (PCM) Transmission Electron Microscopy (TEM) Gravimetric Thermo-optical Analysis (TOA) Inductively-Coupled Plasma Technology sub-type/ Detector Published Reference Method/Title of Inhouse Method FAA NIOSH 7082 GFAA NIOSH 7105 ICP/MS NIOSH 7300 Modified ICP/AES NIOSH 7300 Modified NIOSH 7500 Modified OSHA ID-142 Modified NIOSH 6010 Modified ICP/MS EPA 600/R-93/116 NIOSH 7400 EPA AHERA - 40 CFR Part 763 NIOSH 7402 NIOSH 0500 NIOSH 0600 NIOSH 5524 NIOSH 5040 NIOSH 7300 NIOSH 7303 Method Description or Analyte (for internal methods only) EPA AHERA Method (40 CFR 763, Subpart E, Appendix A, Mandatory Method A complete listing of currently accredited Industrial Hygiene laboratories is available on the AIHA-LAP, LLC website at: Effective: 04/10/ _Scope_IHLAP (Method Addition)_2016_10_20 Page 2 of 2

23 AIHA Laboratory Accreditation Programs, LLC SCOPE OF ACCREDITATION EMSL Analytical, Inc. Laboratory ID: Route 130 North, Cinnaminson, NJ Issue Date: 08/31/2016 The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory s current accreditation status for the particular field(s) of testing/methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation. The EPA recognizes the AIHA-LAP, LLC ELLAP program as meeting the requirements of the National Lead Laboratory Accreditation Program (NLLAP) established under Title X of the Residential Lead-Based Paint Hazard Reduction Act of 1992 and includes paint, soil and dust wipe analysis. Air analysis is not included as part of the NLLAP. Environmental Lead Laboratory Accreditation Program (ELLAP) Initial Accreditation Date: 01/18/1995 Field of Testing (FoT) Technology sub-type/ Detector Method Paint EPA SW B EPA SW B Soil EPA SW B EPA SW B Settled Dust by Wipe EPA SW B EPA SW B Airborne Dust NIOSH 7082 Composited Wipes EPA SW B EPA SW B Method Description (for internal methods only) A complete listing of currently accredited Environmental Lead laboratories is available on the AIHA-LAP, LLC website at: Effective: 05/04/ _Scope_ELLAP_2016_08_31 Page 1 of 1

24 AIHA Laboratory Accreditation Programs, LLC SCOPE OF ACCREDITATION EMSL Analytical, Inc. Laboratory ID: Route 130 North, Cinnaminson, NJ Issue Date: 08/31/2016 The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory s current accreditation status for the particular field(s) of testing/methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation. Environmental Microbiology Laboratory Accreditation Program (EMLAP) Initial Accreditation Date: 09/01/2002 EMLAP Category Fungal Bacterial Field of Testing (FoT) Air - Culturable Bulk - Culturable Surface - Culturable Air - Direct Examination Bulk - Direct Examination Surface - Direct Examination Air - Culturable Bulk - Culturable Surface - Culturable Method M005 M005 M TP M041 M041 M009 M009 M009 Method Description (for internal methods only) Detection and Enumeration of Culturable Fungi from Environmental Samples Detection and Enumeration of Culturable Fungi from Environmental Samples Detection and Enumeration of Culturable Fungi from Environmental Samples Standard Operating Procedure for the Analysis of Airborne Fungal Spores, Hyphal Fragments, Pollen, Insect Fragments, Skin Fragments and Fibrous Particulate by Optical Microscopy of Spore Trap Samples Standard Operating Procedure for the Microscopic Examination of Fungal Spores, Fungal Structures, Hyphae, Pollen, Insect Fragments, and Fibrous Material from Surface Samples Standard Operating Procedure for the Microscopic Examination of Fungal Spores, Fungal Structures, Hyphae, Pollen, Insect Fragments, and Fibrous Material from Surface Samples Detection and Enumeration of Culturable Bacteria from Environmental Samples Detection and Enumeration of Culturable Bacteria from Environmental Samples Detection and Enumeration of Culturable Bacteria from Environmental Samples Effective: 03/12/ _Scope_EMLAP_2016_08_31 Page 1 of 2

25 EMLAP Category Field of Testing (FoT) Method Bacterial Legionella 05-TP-002 Method Description (for internal methods only) Recovery of Legionella from the Environment Using the Center for Disease Control and Prevention s Culture Method A complete listing of currently accredited Environmental Microbiology laboratories is available on the AIHA-LAP, LLC website at: Effective: 03/12/ _Scope_EMLAP_2016_08_31 Page 2 of 2

26