Surface disinfection process

Size: px
Start display at page:

Download "Surface disinfection process"

Transcription

1 SURFACE disinfection Surface disinfection process Contamination control, healthcare safety

2 Why perform dry fogging disinfection? Outbreak containment. Effective destruction of pathogens and multi resistant microorganisms. Controls growth of Aspergillus. Reduces cross contamination risks. Advantages Enhances standard bio-cleaning. Disinfects areas not usually manually cleaned. Safe, non corrosive, on all surfaces and equipment. Performance validated to standard NF-T Description of NF-T ( Standard created by the French Health Authorities, the only one established globally ). Covers a wide variety of microorganisms Bacteria: Pseudomonas aeruginosa, E.coli, Staphylococcus aureus, Enterococcus hirae. Viruse: Adenovirus type 5, Norovirus. Spores: Bacillus subtilis. Fungi & yeast: Candida albicans, Aspergillus brasiliensis. Mycobacteria: Mycobacterium avium, Mycobacterium terrae. Has a defined test protocol Preparation and counting of target microorganisms. Test conditions. Distance between device and target microorganism holder. Saturated test room Micro-organisms holder Results are noted against a time threshold and specified biocide composition Bacteria and mycobacteria >= 5 log. Viruses, yeast & fungi >= 4 log. Spores >= 3 log.

3 The airinspace process HPV PA Multi range biocide using hydrogen peroxide ( H 2 O 2 ) boosted by Peracetic acid (PAA) Example of microorganisms. Exceeds 2009 & 2014 NF standards. Efficient, with just 15 min of contact time. Material friendly, non corrosive. Biodegradable. No residue. Cost effective. PATHOGENS STRAINS Logarythm reduction objectives specified by NF T72-281: 2014 airinspace results BACTERIA FUNGI & YEAST SPORES Pseudomonas aeruginosa Escherichia coli Staphylococcus aureus Enterococcus hirae Candida albicans Aspergillus brasiliensis (niger) Bacillus subtilis Clostridium difficile 5 log 4 log 3 log TUBERCULOSIS & MYCOBACTERIA Mycobacterium terrae Mycobacterium avium 4 log VIRUS Adenovirus 4 log airinspace + product Fast X-CID diffusion: treating up to 14m 3 /min. Easy protocol settings: - Contact time from as little as 15 min. - 2 diffusion protocols: - Standard protocol at 3ml/m 3. - Reinforced protocol at 6ml/m 3. Safe process with echem OX our chemical air treatment. Traceability: up to 500 recorded cycles. X-CID, the biocide solution created by airinspace : - A stabilized and ready to use mixture of ( PAA ) and H 2 O 2 to be used at ambient temperature ( no additions i.e. Ag, formaldehydes, essential oils...). The mixture PAA / H 2 O 2 is well known for high anti-microbial effect without corrosion or solid residue after treatment. Proprietary diffusion nozzle: - No fouling. - No clogging. - Optimized droplet size.

4 RHEA Compact and RHEA Titan: A reliable and easy to use range of foggers Validated in both standard and reinforced protocols. Accurate metering of dispensed solution. Reliable measurement of remaining X-CID. Secure installation of the X-CID bottle with drip free connector. Touch screen controls: - Animated drawings and GIF instructions. - Intuitive: easy access to function menus. USB port to download traceability data. Excellent mobility with the Titan and portability for the Compact. RHEA Compact RHEA Titan Concentrated fogging technology Treat up to 800m 3 with one bottle. Light - just 7.5 Kg. Compact, for use in small areas. Easy to handle. Touch screen. Data saving on USB stick. The dry fogging High Tech device Twice fast as RHEA Compact with 2 jets. Light signal at each step of the process. Additional storage for mask ( PPE ) and H 2 O 2 detector. Connects with echem OX for automatic start of vent process. Integral printer. Remote control. Data download on UBS stick. NF-C tag reader - programmer. Intuitive touch screen. Integrated printer. NF-C technology: avoid input errors and save time. Register parameters of each room, permanently ( user name, hospital, units, patient room number, and room volume ). Place the tag at the room entrance. Automated parameter setting simply by scanning the room tag before each procedure.

5 Surface disinfection: airinspace assist you P R O T E C T M E A S U R E D E L E G AT E Elimination of biocide at the end of the process Accelerate access to the room after disinfection Removal of oxidant components in air. Provides quick decontamination of the room and shortens vent times after surface disinfection. In endoscopy, elimination of acid vapors for security and comfort of co-workers. Individual face mask Protect yourself and your team from H 2 O 2 vapors Comfortable fitting mask. 2 chemical filter cartridges. Double seal for optimal protection. Panoramic view from the large visor. Example of a complete decontamination cycle in an unventilated room of 50 m 3. H 2 O 2 detector Detect the residual quantity of H 2 O 2 in the room before reoccupation Reliable and continuous measurements. Hand-held. Light and robust. Easy to use. Customer service A question? A request? Contact us at: or us at: contact@airinspace.com Service benefits Outbreak response. Routine disinfection procedures. Laboratory deep clean. Trained operators. No stock or equipment required. On site, on the day and time of your choice, we perform the disinfection for you and submit a full report for your files and facilities management.

6 Description Part code Packaging RHEA Compact CP RHEA Titan CP To ORDER X-CID Drum of 2.5l CP01038 Box of 6 drums echem OX CP Hydrogen peroxyde detector CP Individual face mask CP Filters for the face mask CP16103 Box of 2 Copyright airinspace - RHEA Compact and RHEA Titan are registered model - airinspace is registered trademarks - DSVA EN Ed 02 03/ 2017 airinspace 14, rue Jean Monnet Élancourt France T. +33 (0) F. +33 (0) contact@airinspace.com