is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

Size: px
Start display at page:

Download "is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft"

Transcription

1 Certificate No: TE00000XZ Revision No: 2 This is to certify: That the Converter with type designation(s) Vacon 100 series, Issued to Vacon Ltd VS, Finland is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft pplication : Converter for syncronous Motors Range: 0,55 kw to 800 kw / (500) / VC supply. Products approved by this certificate are accepted for installation on all vessels classed by DNV GL. This Certificate is valid until Issued at Høvik on DNV GL local station: Turku for DNV GL pproval Engineer: Nicolay Horn ndreas Kristoffersen Head of Section This Certificate is subject to terms and conditions overleaf. ny significant change in design or construction may render this Certificate invalid. The validity date relates to the Type pproval Certificate and not to the approval of equipment/systems installed. Form code: T 1411a Revision: Page 1 of 5 DNV GL DNV GL and the Horizon Graphic are trademarks of DNV GL S.

2 Name and place of manufacturer Vacon Ltd VS, Finland Vacon (China) Drives Co., Ltd, Haiyan Branch JIXING CITY, ZHEJING PROVINCE, P.R. China Product Description: Vacon 100. converter for use in various marine applications. Mains voltage V, 50/60Hz, 3~ 45 o C continuous current ILout () L xxxx 3,15 MR4 IP21, IP L xxxx 4,25 MR4 IP21, IP L xxxx 5,7 MR4 IP21, IP L xxxx 7,3 MR4 IP21, IP L xxxx 9,5 MR4 IP21, IP L xxxx 11,05 MR4 IP21, IP L xxxx 15,25 MR5 IP21, IP L xxxx 21 MR5 IP21, IP L xxxx 28 MR5 IP21, IP L xxxx 39,5 MR6 IP21, IP L xxxx 55 MR6 IP21, IP L xxxx 68,5 MR7 IP21, IP L xxxx 81,5 MR7 IP21, IP L xxxx 96,5 MR7 IP21, IP L xxxx 127 MR8 IP00 / IP21, IP L xxxx 155 MR8 IP00 / IP21, IP L xxxx 187,5 MR8 IP00 / IP21, IP L xxxx 236 MR9 IP00 / IP21, IP L xxxx 280,5 MR9 IP00 / IP21, IP54 Mains voltage V (500V), 50/60Hz, 3~ 45 o C continuous current ILout () L xxxx 3 MR4 IP21, IP L xxxx 4,1 MR4 IP21, IP L xxxx 4,95 MR4 IP21, IP L xxxx 6,8 MR4 IP21, IP L xxxx 8,8 MR4 IP21, IP L xxxx 10,8 MR4 IP21, IP L xxxx 14 MR5 IP21, IP L xxxx 19,5 MR5 IP21, IP L xxxx 27 MR5 IP21, IP L xxxx 34,5 MR6 IP21, IP L xxxx 42 MR6 IP21, IP L xxxx 53,5 MR6 IP21, IP L xxxx 66,5 MR7 IP21, IP L xxxx 79,5 MR7 IP21, IP L xxxx 96 MR7 IP21, IP54 Form code: T 1411a Revision: Page 2 of 5

3 Mains voltage V (500V), 50/60Hz, 3~ 45 o C continuous current ILout () L xxxx 122,5 MR8 IP00, IP21,IP L xxxx 155 MR8 IP00, IP21,IP L xxxx 187,5 MR8 IP00, IP21,IP L xxxx 233 MR9 IP00, IP21,IP L xxxx 280,5 MR9 IP00, IP21,IP L xxxx 347,5 MR10 IP L xxxx 422,5 MR10 IP L xxxx 490 MR10 IP L xxxx 555 MR10 IP L xxxx 620 MR12 IP L xxxx 690 MR12 IP L xxxx 775 MR12 IP L xxxx 870 MR12 IP L xxxx 980 MR12 IP L xxxx 1050 MR12 IP00 Mains voltage V, 50/60Hz, 3~ 45 o C continuous current ILout L xxxx 3,3 MR5 IP21, IP L xxxx 5 MR5 IP21, IP L xxxx 7,55 MR5 IP21, IP L xxxx 10 MR5 IP21, IP L xxxx 15,75 MR6 IP21, IP L xxxx 20 MR6 IP21, IP L xxxx 24,5 MR6 IP21, IP L xxxx 30,5 MR6 IP21, IP L xxxx 37,5 MR7 IP21, IP L xxxx 46,5 MR7 IP21, IP L xxxx 57 MR7 IP21, IP L xxxx 71 MR8 IP00, IP21,IP L xxxx 90 MR8 IP00, IP21,IP L xxxx 112,5 MR8 IP00, IP21,IP L xxxx 134,5 MR9 IP00, IP21,IP L xxxx 189 MR9 IP00, IP21,IP L xxxx 234,5 MR10 IP L xxxx 293 MR10 IP L xxxx 355 MR10 IP L xxxx 400,5 MR10 IP L xxxx 438 MR12 IP L xxxx 490 MR12 IP L xxxx 555 MR12 IP L xxxx 620 MR12 IP L xxxx 700 MR12 IP L xxxx 735 MR12 IP00 Form code: T 1411a Revision: Page 3 of 5

4 Mains voltage V, 50/60Hz, 3~ 45 o C continuous current ILout L xxxx 6,5 MR6 IP21, IP L xxxx 8,75 MR6 IP21, IP L xxxx 11,75 MR6 IP21, IP L xxxx 15,75 MR6 IP21, IP L xxxx 20 MR6 IP21, IP L xxxx 24,5 MR6 IP21, IP L xxxx 30,5 MR6 IP21, IP L xxxx 37,5 MR7 IP21, IP L xxxx 46,5 MR7 IP21, IP L xxxx 57 MR7 IP21, IP L xxxx 71 MR8 IP00, IP21,IP L xxxx 90 MR8 IP00, IP21,IP L xxxx 112,5 MR8 IP00, IP21,IP L xxxx 134,5 MR9 IP00, IP21,IP L xxxx 157 MR9 IP00, IP21,IP L xxxx 189 MR9 IP00, IP21,IP L xxxx 234,5 MR10 IP L xxxx 293 MR10 IP L xxxx 355 MR10 IP L xxxx 400,5 MR10 IP L xxxx 438 MR12 IP L xxxx 490 MR12 IP L xxxx 555 MR12 IP L xxxx 620 MR12 IP L xxxx 700 MR12 IP L xxxx 735 MR12 IP00 pplication/limitation Supply voltage range: V / (500) V / V, 50/60 Hz Voltage variation: 10 % variation: Hz Output frequency: Hz Temperature range in operation: C derate 1.5% / C, C derate 2,5% / C Temperature class: Vibration class: Humidity class: EMC class*: DNV Standard No 2.4 / IEC C2 To be used on EMC class locations Documents for the actual application are to be submitted for approval in each case in accordance with DNV Rules Pt.4, Ch.8, Sec.1 Table B2. Product Certificate is required for converters 100 kw. * Converters EMC classed C2 according to IEC can be installed in "special distribution zone" Form code: T 1411a Revision: Page 4 of 5

5 and "general power distribution zone" in accordance with IEC provided precautions are taken to attenuate these effects on the distribution system, so the safe operation is assured. ** To be installed in an enclosure with an IP degree in accordance with DNV Rules w.r.t. location. The Type pproval covers hardware and software for the basic controller. Clause for software control: ll changes in software are to be recorded as long as the system is in use on board. The records of all changes are to be forwarded to DNV for evaluation and approval. Major changes in the software are to be approved before being installed in the converter. Type pproval documentation Technical info: VCON 100 C DRIVES SIMPLY SUPERIOR Brochure from Vacon, Vacon 100 series voltage and currect ratings, XL sheet from Vacon. Test reports: SGS Fimko test reports & 3 issued , issued , , 3 &4 mendment no 1 issued , 2 &3 issued , & 5 issued and issued SGS Test Reports no & 2 issued VTT Test Report no VTT-S issued & VTT-S issued Vacon Research Reports no. TED10720 to TED10724 issued & TED10757 issued TÛV Technical Report No , dated Tests carried out Visual inspection, Performance, Power supply failure, Power supply variations, Voltage/frequency variation, Vibration/shock, Dry heat, Damp heat, Insulation resistance, High voltage. EMC: Electrical fast transient (Burst), electrical slow transient (Surge), RF-common mode Voltage, radiated RF-electromagnetic fields, electric discharge (ESD), radiated and conducted emission. Marking of product Vacon Type designation Power Voltage Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the Type pproval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the assessment are: Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensuring traceability between manufacturer s product type marking and Type pproval Certificate. ssessment to be performed at 2 and 3.5 year and at renewal. END OF CERTIFICTE Form code: T 1411a Revision: Page 5 of 5