5-9/16" (141 mm) ø 3-3/4" (95 mm) 1 year on components against manufacturing defects 5 years on LED arrays and drivers ø 6" (152 mm)

Size: px
Start display at page:

Download "5-9/16" (141 mm) ø 3-3/4" (95 mm) 1 year on components against manufacturing defects 5 years on LED arrays and drivers ø 6" (152 mm)"

Transcription

1 PAGE 1/7 Project Notes Fixture Type Date HEF-11XXXXXX (illustrated) HED-11XXXXXX (illustrated) Contraste combined advanced technology LED components to create a new and powerful unit that will meet every specification project needs. Our new HexaLED will deliver the exact lumen output to meet the desired lighting performance that is suitable for a wide variety of architectural apllications including retail stores, restaurants, hotels, office spaces, museums and art galeries, public areas and other interiors. SPECIFICATIONS TRIM DETAILS Requires a 6-3/4" (172 mm) clearance beyond the ceiling level Perfect fit into ceiling FIXED ADJUSTABLE No light leak AJUSTABILITY HEAT SINK Each part of the housing and the trim should be at LEAST 3" (76 mm) from insulation (non-ic configurations) Can fit in ceilings up to 1-1/2" (38 mm) thick Junction box is accessible from below the ceiling for ease of maintenance Tilt: 30 (2.5 incremental adjustment) lockable High-quality extruded molded aluminum heat sink ensuring maximum heat dissipation for optimal performance. 5-9/16" (141 mm) 1/16" (1 mm) 6-1/4" (159 mm) 5-5/8" (143 mm) 1-1/4" (32 mm) 1/16" (1 mm) CEILING CUTOUT ø 7-1/4" (184 mm) ø 3-3/4" (95 mm) ø 8-1/4" (210 mm) ø 3-3/4" (95 mm) ø 8-1/4" (210 mm) CERTIFICATION culus E for damp locations Energy Star (Pending) WARRANTY 1 year on components against manufacturing defects 5 years on LED arrays and drivers ø 6" (152 mm) ø 6" (152 mm)

2 PAGE 2/7 SPECIFICATIONS (CONT D) LIGHT ENGINE STANDARD (SOLID WHITE) Lumileds Luxeon CoB 1211 GEN3 L 50, 000 hours of operation 3-Step MacAdam ellipse (3 SDCM) Color Temperatures: 3,000K - 3,500K - 4,000K CRI: 80+ and 90+ (R9: >50) Delivered Lumens: Performance 20W (2,250 lumens) Performance 28W (3,100 lumens) Performance 36W (3,850 lumens) Performance 50W (5,000 lumens) Power Supply: 120V / 277V Consult housing specification sheet for more details. COMPATIBLE HOUSINGS Remodel Housing New Construction Housing New Construction Housing with Emergency Lighting Performance 20W REHEUE20 REHEUD20 REHEUA20 NWHEUE20 NWHEUD20 NWHEUA20 NWHEUD20-EM Performance 28W REHEUE28 REHEUD28 REHEUA28 NWHEUE28 NWHEUD28 NWHEUA28 NWHEUD28-EM Performance 36W REHEUE36 REHEUD36 REHEUA36 NWHEUE36 NWHEUD36 NWHEUA36 NWHEUD36-EM Performance 50W REHEUE50 REHEUD50 NWHEUE50 NWHEUD50 NWHEUD50-EM For dimming, please visit our Web site frequently to find our suggested compatible dimmers: OPTIC SYSTEM Choice of available lenses: Clear (C) Frosted (F) Optical reflectors available: Spot, Narrow Flood, Flood Standard Spot (S) Narrow Flood (M) Flood (L) * Average beams shown. Consult.ies files on our Website for more details. TRIM FINISHES Plated die-formed steel, with powder coating, Marine Grade option available. The center is adjustable incrementally. Different finishes available: White (-01), Matte White (-11), Matte Black (-22) and Polar Grey (-25)

3 PAGE 3/7 CODIFICATION EXAMPLE HEF-01MG3080MC MODEL TRIM FINISH COLOR TEMPERATURE AND CRI LENS TYPE MARINE GRADE OPTION BEAM ORDERING CODES MODEL TYPE TRIM FINISHES MARINE GRADE OPTION COLOR TEMPERATURES AND CRI BEAMS LENSES HE HE F D Fixed Adjustable White Matte White Matte Black Polar Grey MG (optional) May be applied on all finishes ,000K (80+ CRI) 3,500K (80+ CRI) 4,000K (80+ CRI) 3,000K (90+ CRI) S M L Spot (15 ) Narrow Flood (24 ) Flood (44 ) C F Clear Frosted ,500K (90+ CRI) ,000K (90+ CRI) MARINE GRADE 2-year warranty on finish This option increases the painted finishes resistance by reducing and delaying apparition and propagation of oxidation (ex: rust and others). MARINE GRADE treatment is recommended for damp to wet locations. Unless otherwise indicated, trims are for interior use. Also suitable for cold and exterior locations, as in soffits, where fixtures are not subject to direct rain or snow exposure. WARNING This option is not suitable for salt environments and/or highly corrosive areas such as soffits in coastal regions and natatoriums. Such usage would void warranty on the product.

4 PAGE 4/7 In order to obtain the accurate photometric data, multiply the lumens relative to your product selection by the applicable factor(s). Take note these factors also need to be implemented in the.ies files available on our website. With Performance 20W 3,000K with 80+ CRI 2,076 lm lm/w 2,122 lm lm/w 2,141 lm lm/w 3,500K with 80+ CRI 2,117 lm lm/w 2,164 lm lm/w 2,184 lm lm/w 4,000K with 80+ CRI 2,187 lm lm/w 2,236 lm lm/w 2,256 lm lm/w 3,000K with 90+ CRI 1,783 lm 89.1 lm/w 1,823 lm 91.1 lm/w 1,839 lm 92.0 lm/w 3,500K with 90+ CRI 1,819 lm 90.9 lm/w 1,859 lm 93.0 lm/w 1,876 lm 93.8 lm/w 4,000K with 90+ CRI 1,879 lm 93.9 lm/w 1,920 lm 96.0 lm/w 1,938 lm 96.9 lm/w With Performance 28W 3,000K with 80+ CRI 2,835 lm lm/w 2,898 lm lm/w 2,924 lm lm/w 3,500K with 80+ CRI 2,891 lm lm/w 2,956 lm lm/w 2,982 lm lm/w 4,000K with 80+ CRI 2,987 lm lm/w 3,053 lm lm/w 3,081 lm lm/w 3,000K with 90+ CRI 2,435 lm 87.0 lm/w 2,489 lm 88.9 lm/w 2,512 lm 89.7 lm/w 3,500K with 90+ CRI 2,484 lm 88.7 lm/w 2,539 lm 90.7 lm/w 2,562 lm 91.5 lm/w 4,000K with 90+ CRI 2,566 lm 91.6 lm/w 2,623 lm 93.7 lm/w 2,647 lm 94.5 lm/w With Performance 36W 3,000K with 80+ CRI 3,538 lm 98.3 lm/w 3,616 lm lm/w 3,649 lm lm/w 3,500K with 80+ CRI 3,608 lm lm/w 3,688 lm lm/w 3,722 lm lm/w 4,000K with 80+ CRI 3,728 lm lm/w 3,810 lm lm/w 3,845 lm lm/w 3,000K with 90+ CRI 3,039 lm 84.4 lm/w 3,106 lm 86.3 lm/w 3,134 lm 87.1 lm/w 3,500K with 90+ CRI 3,100 lm 86.1 lm/w 3,168 lm 88.0 lm/w 3,197 lm 88.8 lm/w 4,000K with 90+ CRI 3,202 lm 88.9 lm/w 3,273 lm 90.9 lm/w 3,303 lm 91.7 lm/w

5 PAGE 5/7 With Performance 50W 3,000K with 80+ CRI 4,536 lm 92.6 lm/w 4,637 lm 94.6 lm/w 4,679 lm 95.5 lm/w 3,500K with 80+ CRI 4,627 lm 94.4 lm/w 4,730 lm 96.5 lm/w 4,772 lm 97.4 lm/w 4,000K with 80+ CRI 4,780 lm 97.6 lm/w 4,886 lm 99.7 lm/w 4,930 lm lm/w 3,000K with 90+ CRI 3,897 lm 79.5 lm/w 3,983 lm 81.3 lm/w 4,019 lm 82.0 lm/w 3,500K with 90+ CRI 3,975 lm 81.1 lm/w 4,063 lm 82.9 lm/w 4,099 lm 83.7 lm/w 4,000K with 90+ CRI 4,106 lm 83.8 lm/w 4,197 lm 85.7 lm/w 4,235 lm 86.4 lm/w Lenses Factor C 1 F 0.71

6 PAGE 6/7 4,000K, 80+ CRI, Spot, Performance 50W CANDLEPOWER DISTRIBUTION Candelas 6,333 19,000 31, LIGHT CONE Distance FC DIA 06 1, Beam: 15 Beam Edge defined as 50% of Maximum Nadir Candle-power. LUMINAIRE COEFFICIENT OF UTILIZATION - % Performance 2 LED 4,000K Spot Ceiling Reflect % Wall Reflect % CBCP / Lumens 36,754 / 4,779.6 RCR V 277V Watts W 48.5W Operating AMPS 0.4A 0.18A Lumen Maintenance 50,000 Hrs CRI 80+ Lumens/Watt 99.5 Spacing Criteria 0.07 Zonal Cavity Method Effective Floor Cavity Reflectance 20% ZONAL LUMEN SUMMARY ZONE LUMENS %LUMINAIRE , % , % , % % , % MULTIPLE UNIT DATA - (RCR 2) SPACING ON CENTER INITIAL FOOTCANDLES WATTS/ SQ. FT. 5' ' ' ' ' ' x 38' x 10' Room. Workplan located 2-1/2' (30''). Reflectance factor 80%/50%/30% DISTRIBUTION 0 36, , , , , , ,000K, 80+ CRI, Narrow Flood, Performance 50W CANDLEPOWER DISTRIBUTION Candelas 3,833 11,500 19, LIGHT CONE Distance FC DIA Beam: 24 Beam Edge defined as 50% of Maximum Nadir Candle-power. LUMINAIRE COEFFICIENT OF UTILIZATION - % Performance 2 LED 4,000K Narrow Flood Ceiling Reflect % Wall Reflect % CBCP / Lumens 22,260 / 4,886.1 RCR V 277V Watts W 49.5W Operating AMPS 0.41A 0.18A Lumen Maintenance 50,000 Hrs CRI 80+ Lumens/Watt 99.7 Spacing Criteria 0.10 Zonal Cavity Method Effective Floor Cavity Reflectance 20% ZONAL LUMEN SUMMARY ZONE LUMENS %LUMINAIRE , % , % , % % , % MULTIPLE UNIT DATA - (RCR 2) SPACING ON CENTER INITIAL FOOTCANDLES WATTS/ SQ. FT. 5' ' ' ' ' ' x 38' x 10' Room. Workplan located 2-1/2' (30''). Reflectance factor 80%/50%/30% DISTRIBUTION 0 22, , , , , ,

7 PAGE 7/7 4,000K, 80+ CRI, Flood, Performance 50W CANDLEPOWER DISTRIBUTION Candelas 1,550 4,650 7, LIGHT CONE Distance FC DIA Beam: 44 Beam Edge defined as 50% of Maximum Nadir Candle-power. LUMINAIRE COEFFICIENT OF UTILIZATION - % Performance 2 LED 4,000K Flood Ceiling Reflect % Wall Reflect % CBCP / Lumens 8,466 / 4,930.1 RCR V 277V Watts W 49.5W Operating AMPS 0.41A 0.18A Lumen Maintenance 50,000 Hrs CRI 80+ Lumens/Watt Spacing Criteria 0.19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% ZONAL LUMEN SUMMARY ZONE LUMENS %LUMINAIRE , % , % , % % , % MULTIPLE UNIT DATA - (RCR 2) SPACING ON CENTER INITIAL FOOTCANDLES WATTS/ SQ. FT. 5' ' ' ' ' ' x 38' x 10' Room. Workplan located 2-1/2' (30''). Reflectance factor 80%/50%/30% DISTRIBUTION 5 8, , , , ,