1 STERILITY ASSURANCE Use to monitor and release instrumentation with confidence VERIFY Load Control Products LOAD CONTROL PROCESS CONTROL PACK CONTROL EQUIPMENT CONTROL RECORD KEEPING & LABELING PRODUCT TESTING Quality Control

2 Whether sterilization or high level disinfectio provide the performance you need to reale Challenge Packs Challenge Packs provide consistent tests of the ability to penetrate the load with sterilant. challenge pack represents a difficult challenge to the sterilization process and provides assurance that the load may be released for use. VERIFY SixCess Challenge Packs Used to monitor steam sterilization loads, VERIFY SixCess Challenge Packs contain a Class 6 emulating indicator within a specially designed barrier system. These cycle specific challenge packs provide the precision necessary for stringent performance monitoring of sterilization cycles. VERIFY SixCess Challenge Packs offer a fast, accurate and cost effective means of sterility assurance monitoring and release of steam sterilization loads. The challenge packs are not a substitute for biological indicators and are not intended to release loads containing implants. > Monitor the cycle specific sterilization parameters required > Indicator ink performance meets ANSI/AAMI/ISO Class 6 Emulating Indicator criteria > Immediately identifies failed sterilization cycles > Provides a cost-effective means to monitor every sterilization load > Products for use in extended cycle times LCC003 VERIFY SixCess 270F 4 Challenge Pack (20 packs) (270 F/132 C 4 minute dynamic air removal cycles) LCC014 VERIFY SixCess 275F 3 Challenge Pack (20 packs) (275 F/135 C 3 minute prevacuum cycles) LCC019 VERIFY SixCess 270FP Challenge Pack (20 packs) (270 F/132 C dynamic air removal cycles with 4, 10 or 20 minute exposures) LCC014 LCC003 LCC019

3 n VERIFY Biological and Chemical Indicators ase your instrumentation with confidence. VERIFY Steam Biological/Integrator Challenge Packs (BI Test Pack with Class 5 Integrator) Monitor and release all loads sterilized in 270ºF/132ºC prevacuum and 250ºF/121ºC gravity steam sterilization cycles. pack contains a Class 5 chemical integrator and a VERIFY Self Contained Biological Indicator within a compact disposable challenge pack. VERIFY Steam Biological/Integrator Challenge Packs provide immediate indication that all critical parameters of sterilization have been achieved providing worry-free emergency release when necessary. The biological indicator can be incubated for 24 hours for confirmation of microbial kill. > Integrator strip meets ANSI/AAMI/ISO requirements for Class 5 integrating indicators > For use in 270 F/132 C prevacuum cycles and 250 F/121 C gravity cycles > Class 5 integrator is an accurate predictor of biological indicator growth response LCB006 VERIFY Biological/Integrator Challenge Pack (20 Packs with 5 controls) LCB007 VERIFY Biological/Integrator Challenge Pack VERIFY Activator Set S3082 VERIFY 28-well Incubator S3271 VERIFY 6-well Incubator (20 Packs with 20 controls) VERIFY Biological Steam Test Pack VERIFY Biological Steam Test Packs are compact, lightweight, disposable and have been demonstrated to be equivalent to the AAMI Biological Indicator Test Pack for steam. pack contains a conventional self-contained biological indicator, as required by AAMI, for weekly microbial challenges of your steam sterilizer (250 F/121 C gravity and 270 F/132 C prevacuum). > Meets ANSI/AAMI ST79 requirements for a biological indicator test pack > Prefabricated disposable test pack > Self Contained B1 meets conventional microbial growth requirements as defined by AAMI > Final read at 24 hours incubation S3065 VERIFY Biological (20 packs with Steam Test Pack 5 controls) S3069 S3082 S3271 VERIFY Biological Steam Test Pack VERIFY Activator Set VERIFY 28-well Incubator VERIFY 6-well Incubator (20 packs with 20 controls) S3065 & S3069 S3271 LCB006

4 VERIFY V24 Self-Contained Biological Indicator VERIFY V24 Self Contained Biological Indicator contains Geobacillus stearothermophilus spores and growth media within a self contained vial eliminating the need for aseptic transfer. They are used to monitor V-PRO Low Temperature Sterilizers and STERRAD * Sterilizers. > Validated for use with V-PRO1, 1PLUS, max and 60 Low Temperature Sterilizers > Validated for use in STERRAD 200, NX, and NX Sterilization Systems > No aseptic transfer > Fast final read at 24 hours LCB020 VERIFY V24 Self Contained (50 indicators) Biological Indicator LCB004 VERIFY SCBI VHP Activator S3082 VERIFY 28-well Incubator S3271 VERIFY 6-well Incubator VERIFY Biological EO Test Pack VERIFY EO Test Packs are compact, lightweight, disposable and designed for use in all ethylene oxide sterilization processes, including 100% ethylene oxide. pack contains a self-contained biological indicator within a syringe, assembled within a blister pack. > Meets ANSI/AAMI ST41 requirements for a conventional BI Pack > Prefabricated disposable test pack > Final read at 48 hours incubation S3070 VERIFY Biological (20 packs with EO Test Pack 5 controls) S3071 S3080 VERIFY Biological EO Test Pack VERIFY Activator Set VERIFY 28-well Dual Incubator (20 packs with 20 controls) S3070 & S3071 LCB004 LCB020 *STERRAD is the registered trademark of Advanced Sterilization Products, Division of Ethicon Inc., a Johnson & Johnson Company.

5 IUSS Chemical and Biological Indicators VERIFY Immediate Use Steam Sterilization (IUSS) Chemical and Biological Indicators provide the assurance that your IUSS sterilized items have been exposed to the lethal conditions necessary to achieve sterility. VERIFY SixCess Flash Indicators Used in every IUSS sterilization cycle, VERIFY Chemical Indicators give immediate verification that the conditions for sterilization were achieved. Used to release all IUSS sterilization loads for which they are labeled. Clear yellow to blue/purple color change indicates pass. > 270ºF/132ºC Gravity 3 and 10 minute flash cycles > 275ºF/135ºC Gravity 3 and 10 minute flash cycles > 270ºF/132ºC Express flash sterilization cycles > 270 F/132 C 4 & 1 prevacuum cycle > 275 F/135 C 3 & 1 prevacuum cycle LCC310 VERIFY SixCess 270F Flash (100 strips) Indicator Strip LCC005 VERIFY SixCess 275F Flash (100 strips) Indicator Strip PCC006 VERIFY SixCess 270F 4 minute Indicator Strip Short PCC008 VERIFY SixCess 270F 4 minute Indicator Strip Long PCC034 PCC038 VERIFY SixCess 275F 3 minute Indicator Strip Long VERIFY SixCess 275F 3 minute Indicator Strip Short (200 strips) (100 strips) (100 strips) (200 strips) VERIFY Self Contained Biological Indicators (SCBIs) for Steam and EO VERIFY Self Contained Biological Indicators contain both Geobacillus stearothermophilus and Bacillus atrophaeus spores and eliminate the need for aseptic transfer. They can be used in steam 250 F/121 C gravity, 270 F/132 C prevacuum, 270 F/132 C gravity Flash, 270 F steam-flush pressure pulse and ethylene oxide sterilization processes including 100% ethylene oxide applications. > Can be used in steam (including IUSS cycles) and ethylene oxide sterilization processes > Sturdy construction protects glass media ampoule from premature breakage > Easy-to-use activator > Final read at 24 hour incubation for steam > Final read at 48 hour incubation for EO S3061 S3060 S3080 S3082 S3271 VERIFY Dual Species SCBI (50 SCBIs) VERIFY Dual Species SCBI (100 SCBIs) VERIFY Activator Set VERIFY 28-well Dual Incubator VERIFY 28-well Incubator VERIFY 6-well Incubator LCC310 LCC005 PCC006 PCC008 PCC034 S3061 & S3060 PCC038

6 High-level Disinfection Processes Expect more from your high-level disinfection process monitoring. VERIFY Revital-Ox Chemical Indicators for high-level disinfection are tailor-made to ensure the process and solutions delivered the minimum recommended concentration for a safe disinfection process. VERIFY Process Indicator for Reliance Endoscope Processing System (EPS) The VERIFY Process Indicator has been developed for exclusive monitoring of the High Level Disinfecting Phase of the Reliance EPS System. The indicator demonstrates the successful generation of an effective dose of peracetic acid within the Reliance EPS cycle. > Specificity for peracetic acid and non-reactive with cleaning chemistries > Easy-to-read color change from orange to white PCC029 VERIFY Process Indicator for Reliance EPS Endoscope Processing System (2 bottles, 60 indicators per bottle) Revital-Ox RESERT Solution Test Strip The Revital-Ox RESERT Solution Test Strip for RESERT Solutions has been developed for exclusive monitoring of the Revital-Ox RESERT High Level Disinfectant Solution. The strip confirms that the minimum recommended concentration (MRC) of hydrogen peroxide is present. > Wide solution test strip for easy handling > Easy-to-read light blue to dark black color change PCC030 Revital-Ox RESERT Solution Test Strip (2 bottles, 60 strips per bottle) PCC045 Revital-Ox RESERT Solution Test Strip (1 bottles, 60 strips per bottle)

7

8 Document # M4098EN Rev. A Printed 09/2014, xxxx 2014 STERIS Corporation. All rights reserved. Printed in USA. STERIS Corporation 5960 Heisley Road Mentor, OH USA