Complete product = Frame + Engine + Trim. Series Lumens CRI CCT Beam Dimming Voltage

Size: px
Start display at page:

Download "Complete product = Frame + Engine + Trim. Series Lumens CRI CCT Beam Dimming Voltage"

Transcription

1 Downlighting Project: Location: Cat.No: Type: Calculite LED gen " round AirSeal lm Calculite LED " generation features industry leading visual comfort, excellent uniform illumination over time, and patented installation flexibility. Complete product = Frame + Engine + Trim Lamps: Notes: Qty: Frame example: CRA Series Aperture Installation C R A C Calculite LED R Round A AirSeal IC (/V) Engine example: CLNZU Series Lumens CRI CCT Dimming Voltage CL CL Calculite LED lm lm lm CRI K CRI K K K N Narrow ( ) M Medium ( ) W Wide ( ) Z - V % SOL EldoLED Solo.% D Dali L Lutron LDE EcoSystem fade-to-black U Universal (// V) E ELV (V dimming only) Universal (// V) lm CRI K CRI K K K M Medium ( ) Z - V % W Wide ( ) SOL EldoLED Solo.% E ELV (V dimming only) U Universal (// V) Universal (// V) Trim example: CRDLCCP Series Aperture Style Finish Flange C R C Calculite LED R Round DL Downlight WW Open Wall Wash LW Lensed Wall Wash CW Corner Wall Wash DW Double Wall Wash CL CC CD CZ BK Specular clear Comfort clear Comfort clear diffuse Champagne bronze Black (matte) White (matte) P Polished F Flangeless WH White (matte) White (matte) F Flangeless Accessories (ordered with a flangeless trim) CARFT Mud-in ring for use with flangeless installations.. The lm () option is only compatible with -V (Z) dimming.. The () CRI option is only available with K () and K () CCT.. Corner (CW) and Double (DW) Wall Wash are not available with flangeless (F) option.. CalculiteLEDgen_in_Airseal_CRA Wide (W) beam is ideal for wall washing / applications. page of

2 CARFT CARFT AirSeal (A) Flangeless mud-in ring (CARFT) in mm in mm in mm D in mm in mm in mm Consult factory for wood installation instructions. Detail D in mm in mm Lifetime (TM-) data CASFT Lumens Narrow beam Medium/Wide beam lm lm lm lm D in mm in mm CASFT Detail D Narrow volts freq Drive THD Power factor Light engine CL_NZU V. <% >. ma W V. <% >. CL_NZU V. <% >. ma W V. <% >. CL_NZU V. ma W V. <% >. CL_NZU V. ma W V. <% >. Medium/Wide Light engine volts CL_MZU V freq Drive THD Power factor. <% >. ma W V. <% >. CL_MZU V. <% >. ma W V. <% >. CL_MZU V. ma W V. <% >. CL_MZU V. ma W V. <% >. CalculiteLEDgen_in_Airseal_CRA / page of

3 Frame-in-kits AirSeal Black painted steel housing for dry or plaster ceilings. Pre-installed telescoping mounting bars from " to ". Patented install Mounting frame With no driver attached, this versatile frame is independent of driver accommodating a wide range of lumen packages, driver types and CCTs, including V and V inputs. Close-cut aperture design eliminates the possibility of undesired gap between ceiling opening and reflector flange. Separate wiring compartment for wiring frame to building allows inspection prior to light engine installation. Simple plug-and-play connection between the frame and light engine from below the ceiling eliminates the need for wiring between frame and LED driver, and also saves time during installation and future replacements/upgrades. Plug-and-play receptacle accommodates technology upgrade of light engines and replacements for the life of the building. Drivers - Advance -V % Dimming - Lutron Hi-lume EcoSystem H Series % Dimming - EldoLED ECOdrive Dali % Dimming - EldoLED SOLOdrive -V.% dimming - ELV dimming Optical systems Comfort throughout the space Patented optical system combines primary and secondary optics to provide a true physical cutoff and reflected cutoff virtually eliminating the view of the light source and bright spots in the reflector. A new reflector curve reduces reflector brightness by up to % compared to existing products, allowing for the use of higher lumen packages in smaller apertures without creating bright spots in the ceiling. Quality of light SDCM ensures color consistency from fixture to fixture and over the luminaire s long lifetime. Proprietary optical grade silicone lens with patterned surface provides soft, even beam diffusion without hotspots or dark rings. Light Engine Quick connect pack comprised of light source and driver allow for easy installation and replacement from below ceiling with no need for additional wiring. This allows for - Frame and ceiling installation to be performed while still finalizing details such as lumen packages, CCT and control type. - Easy replacement of electronics at end of life with minimal wasted material and labor required. - Ease and upgradability of technology. Options and Accessories Flangeless mud-in ring: Use CARFT for use with flangless installations. Sloped ceilings: Compatible with sloped ceiling adapters (see SCA spec sheet). ENERGY STAR exceptions. Dali configurations. lm configurations. CRI configurations. Champagne Bronze and Black finishes. V and Emergency configurations. Wall wash configurations. ELV & EldoLED Solo dimming Labels and Listings culus listed for wet locations ENERGY STAR IBEW Union made (light engines & reflectors) RoHS compliant Warranty year warranty on complete system. Complete warranty available at: com/is/content/philipsconsumer/pdfdownloads/ United%States/ODLI_-UPD-en_US- Philips-warranty-indoor-PLS-us.pdf Narrow beam, lm Engine,. lm/w Engine: CLNZU watts : lms. W..%.% '.'..'..' * diameter is where drop to % of maximum. - RCR ' x x ' Room, Workplane.' above floor, //% Reflectances Efficacy:. lm/w Report : T CL = % CC = % BK = % Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = % CRI K = % CRI = % CRI K = % CRI K = % CRI K = % CRI K = % lm = % lm = % lm = % lm = % lm = % lm = %. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C.-: Specifications for the Chromaticity of Solid State Lighting Products.. Tested using absolute photometry as specified in LM: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. CalculiteLEDgen_in_Airseal_CRA / page of

4 Medium beam, lm Engine,. lm/w Engine: CLMZU watts : lms. W..%.% '.'.'.'.'.' * diameter is where drop to % of maximum. - RCR ' x x ' Room, Workplane.' above floor, //% Reflectances Efficacy:. lm/w Report : T CL = % CC = % BK = % Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = % CRI K = % CRI = % CRI K = % CRI K = % CRI K = % CRI K = % lm = % lm = % lm = % lm = % lm = % lm = % Wide beam, lm Engine,. lm/w Engine: CLWZU watts : lms. W..%.% '.'.'.'.. * diameter is where drop to % of maximum. - RCR ' x x ' Room, Workplane.' above floor, //% Reflectances Efficacy:. lm/w Report : T CL = % CC = % BK = % Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = % CRI K = % CRI = % CRI K = % CRI K = % CRI K = % CRI K = % lm = % lm = % lm = % lm = % lm = % lm = %. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C.-: Specifications for the Chromaticity of Solid State Lighting Products.. Tested using absolute photometry as specified in LM: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. CalculiteLEDgen_in_Airseal_CRA / page of

5 CL = % CC = % BK = % CRI K = % CRI = % CRI K = % CRI K = % CRI K = % CRI K = % lm = % lm = % lm = % lm = % lm = % lm = % Wall Wash, lm Engine,. lm/w Room side Wall side Engine: CLWZU Trim: CRWWCL watts : lms. W Efficacy:. lm/w Report : T ' from wall ' on ctr. ' from wall ' on ctr. ' from wall ' on ctr. Lensed Wall Wash, lm Engine,. lm/w Room side Wall side Engine: CLWZU Trim: CRLWCL watts : lms. W Efficacy:. lm/w Report : T ' from wall ' on ctr. ' from wall ' on ctr. ' from wall ' on ctr.. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C.-: Specifications for the Chromaticity of Solid State Lighting Products.. Tested using absolute photometry as specified in LM: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. philips.com/luminaires CalculiteLEDgen_in_Airseal_CRA / page of Philips Lighting, North America Corporation Franklin Square Drive, Somerset, NJ Tel. -- Philips Lighting Canada Ltd. Hillmount Rd, Markham, ON, Canada LC S Tel. --