Control Strategies for PAA Wastewater Disinfection at WWTPs with Variable Effluent Quality

Size: px
Start display at page:

Download "Control Strategies for PAA Wastewater Disinfection at WWTPs with Variable Effluent Quality"

Transcription

1 Control Strategies for PAA Wastewater Disinfection at WWTPs with Variable Effluent Quality Philip Block 1*, Scott Morgan 2, Kati Bell 3, Sarah Stewart 4 1 PeroxyChem, Philadelphia, PA 2 City of Memphis, TN 3 CDM Smith, Nashville, TN 4 CDM Smith, Houston, TX ABSTRACT The dose of peracetic acid that is required to control microbial concentration in wastewaters will depend on a number of factors, including: target microorganism, the disinfection contact time, and the characteristic quality of the wastewater effluent. Wastewater characteristics that impact peracetic acid oxidant demand, and hence disinfection performance, may include natural organic matter, reduced metals, biological oxygen demand, chemical oxygen demand and total suspended solids. For most treated municipal wastewater effluent, the quality of the wastewater is such that the peracetic initial oxidant demand is relatively low and stable over time. This allows PAA dose to be controlled using simple flow-pacing, once the oxidant demand is known. With recent advances in on-line, continuous PAA monitoring probes, feedback control based on effluent PAA residual could also be combined with flow pacing to provide robust and reliable PAA dose control. However, there are situations where wastewater effluent quality is highly variable, due to any number of factors, such as intermittent industrial discharges to the wastewater treatment plant. Changing effluent conditions can result in variable PAA demand; thus, more active control on PAA dosing may be required to optimize PAA performance in an effort to minimize operational costs. KEYWORDS: peracetic acid, disinfection, process control, water quality INTRODUCTION While chlorination is still the most commonly used disinfection technology for municipal wastewater in the US, formation of chlorinated disinfection by-products (DBPs) has become a concern, and is one of the major drivers for wastewater utilities to consider alternative disinfection technologies. In recent years, peracetic acid (PAA) has gained momentum as an alternative disinfection technology to chlorine 1-3 due to its lack of DBP formation, its lower aquatic toxicity profile, and its lower oxidant demand. Upon reaction with bacteria and viruses,

2 natural organic matter, reduced metals and suspended solids, PAA decomposes to oxygen, water and acetic acid. As a result, chlorinated by-products are not formed. In addition, PAA does not persist in the environment once discharged, so quenching, which would be the analogous process to de-chlorination, is typically not required. Peracetic acid is delivered as an equilibrium solution comprised of peracetic acid, hydrogen peroxide, acetic acid (vinegar) and water, and has been used in a variety of industries, including the medical and food safety markets, as a disinfectant and sterilizing agent. While its use as a wastewater disinfectant is relatively new in the US municipal market, its effectiveness on controlling bacterial microorganisms is well-known 4. The effective dose of peracetic acid will depend on a number of factors, including: the target microorganism, disinfection contact time, and the quality of the wastewater effluent. Wastewater characteristics that impact PAA oxidant demand, and hence performance, may include natural organic matter, reduced metals, biological oxygen demand, chemical oxygen demand and total suspended solids. For many wastewater treatment facilities, the quality of the wastewater is such that the PAA oxidant demand is relatively low and stable over long periods, and may only show seasonal variability. In addition, the demand on the PAA is generally very rapid, occurring within the first few minutes of contact time. As a result, once the initial PAA dose is determined through jar or pilot testing, meeting a specific microbial reduction requirement becomes a matter of maintaining a constant PAA dose. This allows for PAA dosing to be controlled using simple flow-pacing. With advances in on-line, continuous PAA monitoring probes, feedback control based on effluent PAA residual can also be combined with flow pacing. However, there are treatment facilities where wastewater effluents have characteristics that are highly variable, with water quality fluctuating weekly, sometimes even daily. This may be due to any number of factors; one example is where wastewater is impacted by industrial discharges that may have compositional changes arising from operational and production scheduling. These changing influent conditions can result in a variable PAA demand. This variable demand may result in either an under-dosing of the PAA, if the residual feedback control cannot keep up with the fluctuating demand changes, or an over-dosing of PAA, if an initial PAA dose is set to cover the worst-case oxidant demand of the wastewater. In such cases, more active control of the PAA dosing is required to optimize PAA performance and achieve reliable microbial control, while minimizing chemical consumption costs. An alternative control scheme is to use influent water quality parameters as input variables to drive a feed-forward control algorithm. This requires an understanding of how specific water quality parameters impact PAA demand over the full range of temporal water quality; and it is important to obtain sufficient data to fit an algebraic formula on which process control can be based.

3 BACKGROUND The City of Memphis M.C. Stiles Wastewater Treatment Plant (WWTP) processes a combined municipal and industrial waste stream. The industrial component of the wastewater is highly variable across a range of industries. As a result, the treated effluent can still contain nonbiodegradable molecules that contribute to chemical oxygen demand, but not biochemical oxygen demand (see Figure 1). When considering disinfection technologies to meet effluent discharge standards at this WWTP, the compounds that impart color to the wastewater effluent render use of UV disinfection impractical due to low UV transmittance (< 10-percent) and represent a significant demand on chemical oxidants such as chlorine and peracetic acid. This demand represents a substantial operating cost for oxidative disinfectants. Additionally, the timedependent nature of the industrial discharges induce a time variable in the oxidant demand, making simple flow-paced disinfectant dosing schemes not practical or cost effective. The high oxidant demand of the effluent and long contact time that is already available at the Stiles WWTP in an existing contact basin also make simple residual, feed-back dosing schemes not cost effective. Figure 1 Variability of color in effluent from the M.C. Stiles WWTP Recent work 5 investigating oxidative disinfectants and the impact of water quality on disinfection efficacy at the Stiles WWTP at the pilot reactor scale; results showed that peracetic acid 6 had a more favorable oxidant demand profile compared to chlorine chemistry. It was also shown that one or more water quality parameters, such as color, chemical oxygen demand (COD) or oxidation-reduction potential (ORP) could be used as a feed-forward control parameter for oxidant dosing. FULL-SCALE PAA TRIAL TO DEVELOP PAA DOSE CONTROL A full-scale, six-month trial of PAA disinfection was conducted at the Stiles WWTP to demonstrate the ability to use a feed-forward control scheme to consistently meet the target

4 microbial reduction required by the WWTP s National Pollutant Discharge Elimination NPDES permit. The objectives of the trial included: Characterization the impact of water quality on peracetic acid (PAA) demand over time, Identification of key water quality parameters for use in feed-forward control of PAA dosing, Development of a PAA dose control algorithm, Determination of the optimal PAA dose to achieve the required Escherichia coli (E. coli) concentration for discharge under the NPDES permit, and Demonstration and verification of continuous PAA control for disinfection compliance. Trial Site Description The Stiles WWTP is owned and operated by the City of Memphis and uses contact-stabilization to meet treatment objectives. Figure 2 shows the general layout of the Stiles WWTP and Table 1 provides an overview of the historical plant performance along with permit limits. Disinfection Contact Tanks Final Clarifiers Contact Stabilization Tanks Screening & Grit Chambers Final Clarifiers Figure 2. Overview of the Stiles WWTP The single grab daily maximum limit for E. coli is 487 cfu/100 ml, with a monthly geometric mean limit of 126 cfu/100 ml. To determine whether PAA could be used to consistently meet these limits, a full-scale PAA trial was conducted at the facility.

5 Table 1. Historical effluent water quality characteristics at the Stiles WWTP. Parameter Minimum observed Daily Performance Data Average or mean 1 Maximum observed Daily (minimum; maximum) Draft NPDES Limit Weekly maximum Monthly maximum Daily Flow 2 (MGD) BOD 3 (mg/l) TSS 3 (mg/l) ph 4 (s.u.) E. coli 5 (cfu/100ml) 1.3 x 10 4 (4.4 x 10 5 as 6.0 x 10 5 geomean) 1.1 x as geomean Apparent color 6 (PtCo units) True color 6 (PtCo units) Apparent UVT 6 (%) Filtered UVT 6 (%) arithmetic means were reported for all values except E. coli which is also reported as a geometric mean 2 average daily influent flow values, period of record: 9/1/09 5/31/13 3 daily values taken from composite effluent samples, period of record: 9/1/09 5/31/13 4 daily values taken from grab effluent samples, period of record: 9/1/09 12/31/12 5 daily values taken from grab effluent samples, period of record: 1/17/08-7/11/13 6 daily values taken from composite effluent samples, period of record: 8/11/11 5/21/13 The Stiles WWTP was originally constructed to provide chlorine disinfection; however, due to concerns over disinfection by-products and their impact on aquatic organisms in the receiving waterbody, the practice was never implemented. Thus, the WWTP has an existing contact chamber (Figure 3); it is a typical two train serpentine configuration designed provide plug flow for 15 minutes at the peak hour flow of 250 million gallons per day (MGD). Flows from the north and south sides of the plant are combined in a mixing chamber at the head of the disinfection contact tank; flow then splits into the north and south channels. It was assumed throughout the PAA trial that flow was completely mixed with respect to flow, water quality and E. coli concentrations in the mixing chamber prior to flow splitting into each of the two channels. At the end of each channel, treated effluent flows over a weir, and combines in a common pipe before being discharged to the Mississippi River.

6 North Effluent weir EC Out PAA 3 BFM PAA 2 PAA 1 DP Influent Effluent Effluent weir EC IN Color COD UVT ph/t Mixing Chamber South Figure 3. Stiles WWTP disinfection contact chamber DP PAA dosing point PAA 1 position of PAA probe 1 PAA 2 position of PAA probe 2 PAA 3 position of PAA probe 3 EC in location of influent E. coli sampling EC out location of effluent E. coli sampling Color location of color probe COD, UVT location of COD / UVT probe ph / T location of ph and temperature probe BFM position of the bubbler flow meter Full-scale Trial Approach The PAA field trial was conducted in five phases, between December 2014 and April During the trial, PAA was dosed into the north side of the disinfection chamber and the south side was used as a control, with no PAA addition. Influent water quality was measured at the head of the south side chamber and disinfected samples were collected at the weir on the north side of the contact tank. Phase 1 was conducted over a two week period during which PAA was flow paced, and water quality parameters were continuously monitored using on-line analyzers: color, chemical oxygen demand (COD), oxidation-reduction potential (ORP), percent UV transmittance at 254 nm

7 (UVT), ph and temperature. Grab samples were collected to evaluate E. coli concentrations at the influent and effluent of the disinfection contact tank. PAA residuals were measured at three locations throughout the contact tank using online monitoring probes. The Phase 1 data were analyzed, and correlations between each water quality parameter, PAA demand and E. coli reduction were performed. The two best parameters were selected based on the highest r 2 value from a least-squares fit of the data to PAA demand, and the greatest sensitivity of that parameter to PAA demand (greatest slope in the change of the quality parameter versus change in the PAA demand). Using the selected parameters, a feed-forward algorithm, coupled with flow pacing, was developed to control PAA dose based on each parameter. Phase 2 was conducted over a two week period, utilizing the dose algorithm developed from Phase 1 data for color. Disinfection performance was evaluated over a wide range of effluent color concentrations and flows. Phase 3 was conducted similarly to Phase 2, except the dose algorithm was based on COD. After Phase 3, the algorithm providing the greatest performance with respect to microbial reductions and PAA use rates was identified for additional testing. Phase 4 was a month long assessment of disinfection performance using the PAA dose algorithm based on color, selected after Phase 3. During this phase, adjustment of the algorithm and base PAA dose was conducted to maximize disinfection performance while minimizing the dose required. Final verification and qualification of the VigorOx WWTII control algorithm was assessed during the final month-long Phase 5. The refined PAA dose algorithm, as determined during Phase 4 was implemented and disinfection performance was monitored. Instrumentation for Monitoring Water Quality Peracetic acid was measured in situ via the Prominent Dulcotest CTE sensor. The sensor is a membrane-capped amperometric, two electrode sensor for the measurement of PAA in aqueous solution. It has a platinum working electrode and a silver halide coated counter or reference electrode. PAA contained in the sample water diffuses through the membrane, causing a potential difference between electrodes. Three PAA submersible probes were placed into the disinfection contact tank (north side, PAA dosing): a 10 ppm PAA probe one quarter of the distance down the contact tank (Probe 1, P1), a 10 ppm PAA probe one half the distance down the contact tank (Probe 2, P2), and a 2 ppm PAA probe located at the effluent weir (Probe 3, P3) (see Figure 3). Wastewater color was measured on-line utilizing a ChemScan UV-3151 Series Analyzer with a flow-through sensor. The analyzer draws a sample of wastewater from the untreated side of the disinfection channel, representative of the influent wastewater, to the main unit, located in a control house adjacent to the disinfection contact tank. Periodic grab samples were collected and measured using a portable HANNA Instruments (HI96127) color meter. Calibration of the ChemScan unit was performed if greater than a 10-percent difference was observed between results from the two instruments. The color analyzer was stable through the course of the trial, requiring minor daily cleaning of an internal filter as its maintenance profile. Wastewater COD and UV transmittance (UVT at 254 nm) was measured online using a submersible YSI CarboVis model 701. Periodic grab samples were collected and measured using a benchtop HACH DRB200 COD analyzer and a bench scale HACH DR5000 spectrophotometer. Calibration of the YSI CarboVis was performed if greater than 10-percent

8 difference between COD or UVT was observed between the online and benchtop instruments. The COD and UVT analyzers remained stable throughout the trial, with cleaning every two to three days. Measurements were made in the control side of the disinfection contact tank. ORP, ph and temperature were measured using a SensoLyt multi-probe. The probes required little maintenance, except for occasional cleaning. Two McCrometer SPI Mag Model 282L Single Point Insertion Electromagnetic Flow Meters (IFM) were inserted, one each, into the north and south side wastewater conduit pipe prior to entering the mixing chamber of the contact tank. The IFM proved to be significantly interfered with by organic solid material within the wastewater. This introduced error into the measured flow, and impacted the target PAA dose concentration via the flow-pacing algorithm. As a result, the IFM were replaced for Phase 4 and 5 with a Teledyne ISCO Signature bubbler-type flow meter (BFM), which was inserted into the disinfection channel right before the outflow weir. The BFM was shown to be highly stable and reproduced accurately the wastewater flow rate as determined upstream by the plant. As the BFM only measures flow through the north side of the disinfection channel, total plant flow was determined as twice the BFM measurement. Disinfection Performance Sampling Grab samples were collected Monday through Friday at the influent, effluent and midpoint of the disinfection contact tank for E. coli (see Figure 3). In Phases 1, 2 and 3, samples were obtained three times a day (at approximately 8 am, 10 am and 2 pm) at the three locations. During Phase 4, samples were collected three times a day, but only at the influent and effluent of the disinfection contact tank. For Phase 5, samples were collected once a day, at 10 am, for both the influent and effluent. Upon collection, the wastewater samples were stabilized using sodium thiosulfate that was provided in the sample containers to quench PAA so that disinfection did not continue during sample transport. E. coli analysis were performed by a third-party laboratory. RESULTS AND DISCUSSION Results of the full-scale trial are presented in the following sections by Phase, with key observations from each Phase being noted. Phase 1: Assessment of Influent Water Quality Parameters The first phase was a ten day trial designed to assess undisinfected wastewater quality (color, COD, UVT and ORP) and the impact on PAA demand. PAA dosing for Phase 1 was initially set at 10 ppm; due to relatively low wastewater flow in later stages of Phase I, very low PAA dose pump speeds caused PAA to be delivered in a discontinuous, pulse-like fashion. To overcome this operational issue, the PAA dose was increased to 15 ppm. Results of effluent color and COD collected during Phase 1 are provided in Figure 4; results of UVT and color and ORP are provided in Figure 5. Wastewater color ranged from a maximum of 1950 to a minimum of 400 color units and COD ranged from 82 to 355 mg/l during this Phase. The high color and COD data were correlated to periods when particularly industrial users were discharging; when these users stopped production, wastewater color decreased substantially.

9 PAA residual at Probe 1 was observed to increase when color decreased; COD also decreased and UV transmittance showed a general increase during this period. The PAA residuals at the midpoint (P2) and end of the contact tank (P3) at the effluent weir were near the detection limit of the analyzer throughout the phase and are not shown; as a result, the analysis of Phase 1 data is based on the residuals reported at the analyzer located nearest the PAA application point (P1). PAA residuals at Probe 1 are shown in Figure 6 along with E. coli results. As shown in Figure 6, when the PAA residual at Probe 1 is 4 ppm or higher, the disinfected E. coli concentration was 126 cfu/100 ml or lower. Figure 4. Color and COD measurements during Phase 1.

10 Figure 5. UVT and ORP measurements during Phase 1 Figure 6. PAA residual at P1 and E. coli measurements during Phase 1.

11 While successful PAA dosing can be achieved by a flow-pacing regime at many WWTPs, the time-dependent water quality demand on PAA at the Stiles WWTP observed during Phase 1 of this trial clearly demonstrates the need to implement feed-forward dosing scheme. This will provide proper dosing of PAA needed to achieve the target microbial reduction in a proactive, instead of reactive mode. The feed-forward dose control algorithm is based on Equation 1. PAA dose = PAA set + PAA demand Equation 1 PAA dose is then flow-paced to using a flow signal. The PAA residual at Probe 1 is thus dependent on two factors: the PAA demand associated with oxidation of non-target compounds in the effluent and flow. Flow impacts the apparent PAA demand due to the time-dependent nature of the demand kinetics and PAA auto-decomposition. Additionally, flow impacts the hydraulics of the disinfection channel, resulting in non-ideal flow for some flow regimes. For each water quality parameter, PAA demand is assessed through statistical analysis of PAA residual as a function of the wastewater quality parameter and flow. Based on the statistical analyses, wastewater color (r 2 = 0.70) and COD (r 2 = 0.66) were selected for building dose control algorithms further testing. The UVT of the effluent was too low (< 5- percent) to provide adequate sensitivity for dose control; ORP did not provide a sufficient fit (low r 2 ) to be selected as a parameter for control. Phase 2: Effluent Color for Feed-forward Dose Control During Phase 2, color was used as a feed-forward control parameter for PAA dosing. The first E. coli sample point was moved to a position coincident with PAA Probe 1 because there was only a very small difference between the E. coli concentrations halfway through the contact tank and those at the end of the basin, collected at the effluent weir. PAA demand was determined as a function of wastewater color, based on Phase 1 data. Color was continuously monitored, and PAA demand was calculated from the measured color value. During Phase 2, low and high PAA set values were evaluated and PAA dose was paced using a signal from the flow meter. Data for PAA dose were plotted along with effluent color, and PAA residual at Probe 1, and are provided in Figure 7; during this phase ranged from 590 to 2000 PtCo units. Again, the PAA residuals at P2 and P3 were near the detection limit of the analyzer throughout the phase and are not shown; as a result, the analysis of data for the rest of the study is based on the residuals reported at P1, which are shown in Figure 8 along with E. coli results.

12 Figure 7. Color and PAA residual measurements during Phase 2. Figure 8. E. coli results and PAA residual measurements at Probe 1 during Phase 2.

13 It is of note that during Phase 2, the data logger stopped recording from January 8, 2015, 9:10 am to January 9, 2015, 1:00 pm; while the cause of this was not determined, it does not alter the conclusions drawn from Phase 2. Additionally, in Figure 2, an increase in PAA dose is noted on January 12, 2015; this was the planned increase in PAA dose halfway through the study. Results of E. coli testing showed that color was a good feed forward parameter for managing disinfection process control. All E. coli samples were below the maximum daily limit of 487 cfu/100ml and, all but two samples were below the monthly geometric mean limit of 126 cfu/100 ml which would easily meet disinfection compliance requirements. The E. coli data at Probe 1 shows that in most cases, the majority of the disinfection is accomplished in the first few minutes of contact; however, it is necessary to provide additional contact time to achieve disinfection to meet permit requirements. In addition to the online color data collected on the undisinfected effluent, grab samples were also collected at the influent (at the location of the water quality probes) and at the effluent of the contact basin (near Probe 3) for laboratory measurements of apparent and true color. Apparent color is the direct color reading of the sample, while true color represents the results of the filtered sample. Data for these daily grab samples is summarized in Table 2. It is of note that on average, throughout the treatment in Phase 2 of testing, that the PAA reduced the color of the effluent by approximately 100 Platinum-Cobalt (PtCo) units. It was not anticipated that PAA would have a significant impact on effluent color; this is a secondary benefit of PAA for disinfection at the Stiles WWTP. Table 2. Summary of daily apparent and true color data collected from grab samples Date Apparent Color (PtCo units) True (filtered) Color (PtCo units) Untreated flow PAA treated flow Difference Untreated flow PAA treated flow Difference 01/08/ /09/ /10/ /11/ /12/ /13/ /14/ /15/ /16/ /17/ /18/ Average Color Reduction Phase 3: Effluent COD for Feed-forward Dose Control Phase 3 was conducted over a ten day period using COD as the feed-forward control in the PAA dosing algorithm. PAA demand was determined as a function of wastewater COD based on Phase 1 data. COD was continuously monitored, and PAA demand was calculated from the measured COD value. During Phase 3, a high and a low PAA set value was tested with PAA dose being paced

14 using a flow signal. Phase 3 data for PAA dose was plotted along with effluent COD, and PAA residual measured at Probe 1 in Figure 9. Figure 9. COD and PAA residual measurements during Phase 3. In reviewing Phase 3 data, there were two disruptions in data collection. The first occurred from January 22, 2015 at 8:20 am to 6:30 pm when the PLC control became inoperative due to a spurious signal being sent to the control algorithm; this programming issue was corrected. The second disruption occurred during a loss of power to the plant from January 22, 2015 at 9:40 pm to January 23, 2015 at 7:30 am. The loss of plant power caused a fault in the PAA dosing pump, which required a manual restart which did not occur until the morning of January 23rd. Both disruptions caused a loss in monitoring data and a disruption of PAA addition to the disinfection channel, however, this loss of data does not significantly impact the conclusions drawn from Phase 3. Considering process implications from the trial, the design team will include both process and power redundancy in the final design of the system to prevent loss of PAA addition that would result in loss of microbial control. During Phase 3, effluent COD ranged from 128 to 413 mg/l, representing a range of wastewater quality (Figure 9). Figure 10 shows undisinfected E. coli concentrations along with treated samples at PAA Probe 1 and at the effluent weir at the contact tank. In Figure 10, the dashed red line indicates the daily maximum of 487 cfu/100ml and the solid red line is the monthly

15 geomean of 126 cfu/100ml. When PAA set was set at a high value, E. coli at the effluent weir were below 487 cfu/100ml, but many exceeded the 126 cfu/100ml geometric mean limit. When the PAA set value was decreased, the test demonstrated the point of compliance failure, i.e., where many of the effluent E. coli concentrations were above the maximum daily limit. This testing to failure helps identify the minimum PAA set needed to achieve consistent E. coli control. Figure 10. E. coli results and PAA residual measurements at Probe 1 during Phase 3. Phase 1 demonstrated that color and COD were the best quality parameters for use in the feedforward PAA dose control. Phases 2 and 3 showed that the PAA dose can be adequately controlled using either wastewater color or COD. However, wastewater color was selected as the best water quality parameter for process control based on the following findings: While both the color and COD probes proved to be reliable throughout the field trial, the color probe required less maintenance, approximately 5 10 minutes of cleaning the inline filter per day, resulting in less change in measured color before and after maintenance. The COD probe required minutes of cleaning (scrubbing the organic residue from the surface) every fourth day. The sensitivity of the color measurement with respect to PAA dosage was higher than that for the COD measurement ( PAA dose/ water quality parameter), allowing for finer control of PAA dosing with the color parameter.

16 Phase 4: Adjustment of Algorithm Using Color for Feed-forward Dose Control Based on analysis of the Phase 2 and Phase 3 results, PAA set was programmed to 7 ppm for Phase 4, which was designed to allow for additional minor adjustments to the dosing algorithm to optimize chemical use. During Phase 4, severe weather impacted the delivery of chemicals to the temporary trial system. Thus, a conservation program was initiated part way through Phase 4 to reduce the amount of chemical used when critical data was not being collected. The conservation program consisted of reducing the dosage of PAA into the disinfection contact tank to a flow-paced 2 ppm, during periods when E. coli sampling did not occur (weekends and weekday evening hours). It was shown that this reduction in off-hour PAA usage did not negatively interfere with E. coli control during the weekday sampling periods and did not impact the demonstration of the PAA efficacy. The PAA residual at Probe 1 is plotted along with undisinfected and effluent weir E. coli data collected in Figure 12. Figure 11. Color, PAA dose and PAA residual measurements during Phase 4. Figure 11 shows the PAA dose based on the control algorithm and the measured color values. It is of note that during the latter part of Phase 4, the PAA conservation mode was put into effect and did not impact the monitoring that was used to develop an assessment of the process as shown in Figure 12, which provides the undisinfected and effluent weir E. coli concentrations along with the PAA residuals at Probe 1. The dashed and solid red lines in Figure 12 represent the daily maximum concentration of 487 cfu/100ml and the monthly geometric mean of 126 cfu/ml, respectively.

17 Figure 12. E. coli results and PAA residual measurements at Probe 1 during Phase 4. In addition to the conservation mode that was implemented during the latter part of Phase 4 (as shown by the PAA residual oscillations in Figure 12), one other operational issue should be noted in interpretation of the data from this phase of work. On the evening of February 19 th and the morning of February 20 th, extremely cold weather caused the sample line to the color analyzer to freeze, resulting in a loss PAA dose control. During that event, the PAA dose was automatically set to the PAA set, which was a constant 7 ppm. This default operating condition did not provide a high enough PAA dose to meet the demand associated with the highly colored effluent, negatively impacting disinfection performance. As shown in Figure 12, the effluent E. coli on the morning of February 20 th exceeded the daily maximum limit. While this would have been a non-compliance event in the final, permitted system, this event also highlighted design considerations that would need to be addressed in the final system design. While there was a single non-compliance event as a result of operational issues, the remaining tests demonstrated excellent results over several cycles of wastewater

18 quality and flows; effluent color ranged from 450 to 3000 color units and flows varied from below 45 mgd up to 135 mgd. Phase 5: Validation of the Peracetic Acid Dosing System The operational and programming challenges that were identified in the previous phases were reconciled and the final dosing control algorithm was set for Phase 5, which was a demonstration of the ability of the system to meet compliance over a one month period. Validation of the system and verification of a success trial demonstration was defined as meeting the permit limits for E. coli throughout Phase 5 based on daily samples. The PAA set for Phase 5 was 7 ppm; additionally, the PAA conservation program was also continued during Phase 5, and consisted of reducing the dosage of PAA into the disinfection contact tank to a flow-paced 2 ppm, during periods when E. coli sampling did not occur (weekends and evenings). Results of the online monitoring for effluent color, PAA dose and PAA residual at Probe 1 are shown in Figure 13. E. coli were measured at the influent and effluent weir over the course of the thirty day Phase 5 trial with one sampling period per day as shown in Figure 14. Figure 13. Color, PAA dose and PAA residual measurements at Probe 1 during Phase 5. During Phase 5 flow ranged from 75 to 130 MGD which included the highest flow through the plant observed during the six month trial; these high flows represented the shortest contact times observed. Effluent color was generally high throughout Phase 5, ranging from 1000 to 3000 PtCo

19 units. Based on the set dose of 7 ppm and the demand from the color, the PAA dose concentration ranged from approximately 12 to 16 ppm during this phase. During Phase 5, some of the highest undisinfected E. coli concentrations in the trial were observed, with concentrations exceeding 1.2 million cfu/100ml. In all samples, the effluent weir E. coli concentrations were below the daily maximum of 487 cfu/100ml, with only one sample exceeding the monthly geometric mean of 126 cfu/100 ml at a concentration of 204 cfu/100ml, on March 19 th. The geometric mean of the E. coli data collected during the thirty-day period was 4 cfu/100 ml, this included non-detect values to be calculated as 0.9 cfu/100 ml. Additionally, the PAA dose algorithm was able to provide excellent treatment performance at very high color and high undisinfected E. coli concentrations. Figure 13. Color, PAA dose and PAA residual measurements at Probe 1 during Phase 5. CONCLUSIONS The six-month full scale trial successfully demonstrated the ability to use a dose pacing plus feed forward algorithm to provide continuous disinfection at the Stiles WWTP. This process control strategy allows the City of Memphis to address the bacteria limits in their NPDES permit while minimizing the chemical costs associated with implementing PAA disinfection. Disinfection performance was demonstrated over a broad range of water quality and flows; thus, in addition to

20 achieving a monthly geometric mean E. coli concentration of less than the NPDES permit limit of 126 cfu/100ml, the system was demonstrated under conditions of high wastewater color (high PAA demand), high wastewater flow rate (short contact time) and high influent E. coli concentrations. The trial also allowed demonstration of the functionality and stability of water quality monitoring and PAA residual probes, when proper maintenance is conducted. Finally, the full-scale trial allowed engineers to gain insight into important factors for final design of the permanent, full-scale PAA disinfection system. This permanent system will be designed to meet a peak hour flow of up to 250 MGD will be the largest full-scale PAA disinfection system in the US. REFERENCES 1. B. Keogh and M. Tran (2011). Old City, New Ideas: Peracetic Acid in Wastewater Disinfection at St. Augustine. Florida Water Resources Journal, April issue. 2. Bell, K.Y. and Archer, T.A. (2013a). Design and Operation Considerations for PAA Disinfection Systems. WEF Disinfection Conference, Indianapolis, IN, invited speaker. 3. Bell, K.Y., and Archer, T. (2013b). PAA An Alternative for Wastewater Disinfection: Engineering and Cost Considerations. WEF Technology and Exhibition Conference, Chicago, IL. 4. S. Rossi, M. Antonelli, V. Mezzanotte and C. Nurrizo (2007). Peracetic Acid Disinfection: An Alternative to Wastewater Chlorination. Water Env Res, 79, p K. Bell, S. Stewart, S. Morgan, J. Goldman. PAA as a Disinfection Alternative for Challenging Municipal Effluent: MC Stiles WWTP, Memphis, TN. WEFTEC 2014, New Orleans. 6. PeroxyChem s VigorOx WWT II peracetic acid (15% peracetic acid / 23% hydrogen peroxide formulation). The VigorOx WWT II peracetic acid SDS can be found at

Disinfection of Secondary Effluent Using 22% Peracetic Acid at the M.C. Stiles Wastewater Treatment Facility

Disinfection of Secondary Effluent Using 22% Peracetic Acid at the M.C. Stiles Wastewater Treatment Facility Disinfection of Secondary Effluent Using 22% Peracetic Acid at the M.C. Stiles Wastewater Treatment Facility Brent Bankosky, Business Manager Phillip Harvey, VP, Operations Joseph Donabed, R&D Manager

More information

The Application and Measurement of Peracetic Acid for Wastewater Disinfection

The Application and Measurement of Peracetic Acid for Wastewater Disinfection The Application and Measurement of Peracetic Acid for Wastewater Disinfection 2016 Good Laboratory Practices Conference Joanne Carpenter, CHEMetrics, Inc. Philip Block, Ph.D, PeroxyChem Audience Survey

More information

Old City, New Ideas: Peracetic Acid in Wastewater Disinfection at St. Augustine

Old City, New Ideas: Peracetic Acid in Wastewater Disinfection at St. Augustine Old City, New Ideas: Peracetic Acid in Wastewater Disinfection at St. Augustine Situation Wastewater treatment plants are required to disinfect effluent prior to discharge in order to destroy any pathogenic

More information

Session 311: Effects of TSS on Peracetic Acid Dosing for CSO Events

Session 311: Effects of TSS on Peracetic Acid Dosing for CSO Events Session 311: Effects of TSS on Peracetic Acid Dosing for CSO Events Authors: Robert Freeborn, Jacquelyn Wilson Background Peracetic acid has been used in the food and beverage industry since the 1950 s

More information

MUNICIPALITY OF WEST ELGIN RODNEY WASTEWATER TREATMENT PLANT

MUNICIPALITY OF WEST ELGIN RODNEY WASTEWATER TREATMENT PLANT MUNICIPALITY OF WEST ELGIN RODNEY WASTEWATER TREATMENT PLANT 214 ANNUAL REPORT uary 1 to ember 31, 214 Environmental Compliance Approval # 3-871-88-949 Prepared by: Table of Contents Section 1: Overview...

More information

Using PAA as an Alternative WWTP Disinfection Method

Using PAA as an Alternative WWTP Disinfection Method Using PAA as an Alternative WWTP Disinfection Method Angie Mettlen WK Dickson Jeremy Brashears, PE WK Dickson John Thorne - WDJ Environmental March 26, 2018 What is Peracetic Acid? Comparative Oxidation

More information

11.0 EFFLUENT DISINFECTION

11.0 EFFLUENT DISINFECTION SEWPCC Upgrading/Expansion Conceptual Design Report SECTION 11 - Table of Contents 11.0 EFFLUENT DISINFECTION...11.1 11.1 PURPOSE OF UNIT PROCESS...11.1 11.2 EXISTING DISINFECTION FACILITY...11.2 11.2.1

More information

Georgia Power Plant Bowen NPDES Permit No. GA Ash Pond Dewatering Plan. Revised December 2017

Georgia Power Plant Bowen NPDES Permit No. GA Ash Pond Dewatering Plan. Revised December 2017 Georgia Power Plant Bowen NPDES Permit No. GA0001449 Revised December 2017 Purpose This (Plan) describes the additional procedures, safeguards and enhanced wastewater treatment measures that Georgia Power

More information

CITY OF STEUBENVILLE, OHIO WASTEWATER TREATMENT FACILITY

CITY OF STEUBENVILLE, OHIO WASTEWATER TREATMENT FACILITY CITY OF STEUBENVILLE, OHIO WASTEWATER TREATMENT FACILITY PAA Pilot Demonstration to determine PAA Efficacy as an alternative disinfectant to Chlorine and Sodium Bisulfite technology for wastewater Authors

More information

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2014

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2014 CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2014 PREPARED: January 2015 2014 ANNUAL PERFORMANCE REPORT FOR THE CITY OF OXFORD WASTEWATER TREATMENT FICILITY

More information

EWRI Pittsburgh Section Meeting October 30, U.S. EPA, Cincinnati, OH CB&I Federal Services LLC, Cincinnati, OH

EWRI Pittsburgh Section Meeting October 30, U.S. EPA, Cincinnati, OH CB&I Federal Services LLC, Cincinnati, OH Comparing Peracetic Acid with Sodium Hypochlorite for Disinfection of Combined Sewer Overflows Craig Patterson, P.E. 1, Don Schupp, P.E. 2, Bruce Smith, P.E. 3, Bob Freeborn 4, John Maziuk 5, Vasudevan

More information

Non Contact UV System at the Yakima Regional WWTP

Non Contact UV System at the Yakima Regional WWTP Installation of a Flow Through- Non Contact UV System at the Yakima Regional WWTP Sean Goris, P.E. Engineering Manager September 15, 2009 Yakima Treatment Facility Background Secondary treatment facility

More information

With increasing risk management requirements. Wastewater UV Disinfection Systems Lessons Learned During Performance Testing

With increasing risk management requirements. Wastewater UV Disinfection Systems Lessons Learned During Performance Testing Wastewater UV Disinfection Systems Lessons Learned During Performance Testing Cody L. Charnas 1, Katherine Y. Bell 2, Ph.D., PE, BCEE Dale Adams 3, PE, Jed Chambers 3, Dean Cohrs 3, Dan Hammer 3, Pat Schmidt

More information

MUNICIPALITY OF WEST ELGIN WEST LORNE WASTEWATER TREATMENT PLANT

MUNICIPALITY OF WEST ELGIN WEST LORNE WASTEWATER TREATMENT PLANT MUNICIPALITY OF WEST ELGIN WEST LORNE WASTEWATER TREATMENT PLANT 214 ANNUAL REPORT uary 1 to ember 31, 214 Environmental Compliance Approval # 3-442-9-938 Prepared by: Table of Contents Section 1: Overview...

More information

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2018

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2018 CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2018 PREPARED: January 2019 2018 ANNUAL PERFORMANCE REPORT FOR THE CITY OF OXFORD WASTEWATER TREATMENT FICILITY

More information

FULL SCALE PILOT STUDY USING THE VTX PROCESS FOR THE REMOVAL OF SULFIDE AT THE VIRGINIA INITIATIVE PLANT

FULL SCALE PILOT STUDY USING THE VTX PROCESS FOR THE REMOVAL OF SULFIDE AT THE VIRGINIA INITIATIVE PLANT FULL SCALE PILOT STUDY USING THE VTX PROCESS FOR THE REMOVAL OF SULFIDE AT THE VIRGINIA INITIATIVE PLANT Ghosn, S. Plant Manager, and Groszek, G. Lead Operator. Virginia Initiative Plant, Hampton Roads

More information

ENHANCING THE PERFORMANCE OF OXIDATION DITCHES. Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis

ENHANCING THE PERFORMANCE OF OXIDATION DITCHES. Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis ENHANCING THE PERFORMANCE OF OXIDATION DITCHES Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis ABSTRACT Oxidation ditches are very popular wastewater treatment

More information

The Impact of VigorOx WWT II Wastewater Disinfection Technology on Endocrine Disruptors. ED Deactivation Bench Test Procedure

The Impact of VigorOx WWT II Wastewater Disinfection Technology on Endocrine Disruptors. ED Deactivation Bench Test Procedure Disinfection Forum No 8, June 2015 The Impact of VigorOx WWT II Wastewater Disinfection Technology on Endocrine Disruptors Endocrine disruptors (EDs) are a class of chemicals with the ability to interfere

More information

Module 5: Disinfection and Chlorination Answer Key

Module 5: Disinfection and Chlorination Answer Key Module 5: Disinfection and Chlorination Answer Key What processes in wastewater treatment serve to remove pathogens? See Table at top of page 1-3. Exercise for Unit 1 Disinfection and Chlorination Principles

More information

UV DISINFECTION OF LOW TRANSMITTANCE PHARMACEUTICAL WASTEWATER

UV DISINFECTION OF LOW TRANSMITTANCE PHARMACEUTICAL WASTEWATER UV DISINFECTION OF LOW TRANSMITTANCE PHARMACEUTICAL WASTEWATER Jurek Patoczka, PhD, PE Hatch Mott MacDonald, 27 Bleeker Str., Millburn, NJ 74 jurek.patoczka@hatchmott.com ABSTRACT An UV disinfection system

More information

Aquatic Toxicity and Fate of VigorOx WWT II

Aquatic Toxicity and Fate of VigorOx WWT II Aquatic Toxicity and Fate of VigorOx WWT II June 2014 Table of Contents Acronyms / Definitions 3 Content 4 Background 4 Aquatic Fate of VigorOx WWT II 5 Aquatic Toxicity 6 Aquatic toxicity testing specific

More information

RE: Annual Report 2016 Wardsville Wastewater Treatment Plant and Collection System

RE: Annual Report 2016 Wardsville Wastewater Treatment Plant and Collection System 14 th, 217 Tom Clubb 3232 White Oak Road, 3 rd Floor London ON N6E 1L8 Attention: Mr. Clubb RE: Annual Report 216 Wardsville Wastewater Treatment Plant and Collection System The Ontario Clean Water Agency

More information

At the Mercy of the Process Impacts of Nitrogen Removal Performance on WWTP Disinfection

At the Mercy of the Process Impacts of Nitrogen Removal Performance on WWTP Disinfection OBG PRESENTS: At the Mercy of the Process Impacts of Nitrogen Removal Performance on WWTP Disinfection Ned Talbot, PE Tri-Association Conference 2018 8/30/18 9:00-9:30AM AGENDA Overview of Plant Processes

More information

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2012

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2012 CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2012 PREPARED: January 2013 2012 ANNUAL PERFORMANCE REPORT FOR THE CITY OF OXFORD WASTEWATER TREATMENT FICILITY

More information

Analytical Instrumentation for Wastewater Monitoring

Analytical Instrumentation for Wastewater Monitoring January 23, 2014 Analytical Instrumentation for Wastewater Monitoring ONLINE MONITORING FOR INDUSTRIAL WWT APPLICATIONS 1 Did you see this? It is sooo cold. 2 Rob Smith, P.E., BCEE, Ph.D. Applications

More information

Facilities Plan. Technical Memorandum Nos. TM-CSO-11 and TM-WW-5 Disinfection Facilities

Facilities Plan. Technical Memorandum Nos. TM-CSO-11 and TM-WW-5 Disinfection Facilities City of St. Joseph, Missouri Technical Memorandum Nos. TM-CSO-11 and TM-WW-5 Disinfection Facilities By Work Order No. 09-001 B&V Project 163509 July 31, 2009 Technical Memorandum Nos. TM-CSO-11/TM-WW-5

More information

COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL

COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL Alvin C. Firmin CDM Jefferson Mill, 670 North Commercial Street Suite 201 Manchester, New Hampshire 03101 ABSTRACT Sequencing

More information

NC-PC Industry Day Pretreatment 101. Industrial Waste Impacts on POTW Treatment Processes. Dawn Padgett Operations Manager Charlotte Water

NC-PC Industry Day Pretreatment 101. Industrial Waste Impacts on POTW Treatment Processes. Dawn Padgett Operations Manager Charlotte Water NC-PC Industry Day Pretreatment 101 Industrial Waste Impacts on POTW Treatment Processes Dawn Padgett Operations Manager Charlotte Water NC-PC Industry Day Definitions BOD Amount of oxygen consumed by

More information

BIOTECTOR TOC Analysers

BIOTECTOR TOC Analysers BIOTECTOR TOC Analysers Reliable and accurate measurement of Total Organic Carbon in potable and waste water streams Adrian Hughes Process Sales Consultant What is TOC The TOC test measures the amount

More information

Algae Removal from a Facultative Lagoon System Using Dissolved Air Flotation. J. Patrick Pierce, P.E. Environmental Treatment Systems, Inc.

Algae Removal from a Facultative Lagoon System Using Dissolved Air Flotation. J. Patrick Pierce, P.E. Environmental Treatment Systems, Inc. Algae Removal from a Facultative Lagoon System Using Dissolved Air Flotation J. Patrick Pierce, P.E. Environmental Treatment Systems, Inc. Facultative Lagoon System Designed for 1.5 MGD Discharging 1.15-1.35

More information

WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES

WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES A range of potential ammonia limits were identified for alternatives evaluation, as discussed in Section 2.2.5. This chapter

More information

PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS www.zapstechnologies.com PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS By Bud Dunbar ZAPS Technologies 617-448-0440 robert.dunbar@zapstechnologies.com 1 2 WHAT S CHANGED? INEXPENSIVE & POWERFUL PHOTON

More information

Brightwater: The Design Challenges of a 39 mgd (150 MLD) Membrane Bioreactor

Brightwater: The Design Challenges of a 39 mgd (150 MLD) Membrane Bioreactor Brightwater: The Design Challenges of a 39 mgd (150 MLD) Membrane Bioreactor J. Komorita 1, P. Burke 2, B. Youker 2, and G. Crawford 2 1 King County, 2 CH2M HILL ABSTRACT Many Membrane Bioreactor (MBR)

More information

SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES

SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES Oxidation ditches are very popular wastewater treatment processes for small to medium sized municipalities that

More information

USPE Environmental Conference Nashville, TN March 10, 2011

USPE Environmental Conference Nashville, TN March 10, 2011 USPE Environmental Conference Nashville, TN March 10, 2011 Vernon D. Rowe, P.E. rowenvironmental 145 Jefferson Street Pittsburg, Tx 75686 (903) 856-5133 fax (903) 856-5134 cell (903) 767-0945 email rowenvironmental@hotmail.com

More information

Water Quality Permitting Program Monitoring Matrix 1,2,3

Water Quality Permitting Program Monitoring Matrix 1,2,3 State of Oregon Department of Environmental Quality Water Quality Permitting Program Monitoring Matrix 1,2,3 ITEM OR PARAMETER Total Flow (influent and/or effluent) 4 Flow Meter Calibration 5 (influent

More information

WEFTEC.06. Lake Okeechobee, Actiflo, peroxone, surface water, Cyanobacteria

WEFTEC.06. Lake Okeechobee, Actiflo, peroxone, surface water, Cyanobacteria FRESH IDEAS FOR FRESH WATER: OKEECHOBEE UTILITY AUTHORITY S SURFACE WATER TREATMENT PLANT USES INNOVATIVE TECHNOLOGY TO ACHIEVE HIGH QUALITY DRINKING WATER FROM LAKE OKEECHOBEE By: Curtis Robinson, E.I.

More information

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic.

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic. PHASED ACTIVATED SLUDGE SYSTEM PHASED ACTIVATED SLUDGE SYSTEM Aqua-Aerobic Systems has led the industry in time-managed, biological technology since 1984. In 2004, Aqua-Aerobic applied its expertise in

More information

The following biological nutrient removal processes were evaluated in detail in the 2016 Liquid Processing Facilities Plan:

The following biological nutrient removal processes were evaluated in detail in the 2016 Liquid Processing Facilities Plan: Nitrite Shunt Pilot Project Purpose: The purpose of this project is to full scale pilot test the nitrite shunt biological nutrient removal process to confirm process design criteria, impacts to sludge

More information

City of Paso Robles Uses Online Monitor to Detect Low-Level of THMs in Treated Wastewater

City of Paso Robles Uses Online Monitor to Detect Low-Level of THMs in Treated Wastewater City of Paso Robles Uses Online Monitor to Detect Low-Level of THMs in Treated Wastewater The City of Paso Robles, California used an online water quality instrument to characterize and monitor low-levels

More information

Actual Value: Monthly average amount of Flow, COD, and TSS contributed to the SROG system by each SROG city

Actual Value: Monthly average amount of Flow, COD, and TSS contributed to the SROG system by each SROG city Achieved Actual Demand: Actual demand for each city, provided that the city had less than three days below actual demand during the month. If a city has three or more days below actual demand, the achieved

More information

Georgia Power Plant McDonough-Atkinson NPDES Permit No. GA Ash Pond Dewatering Plan. Revised May 2018

Georgia Power Plant McDonough-Atkinson NPDES Permit No. GA Ash Pond Dewatering Plan. Revised May 2018 Georgia Power Plant McDonough-Atkinson NPDES Permit No. GA0001431 Revised May 2018 Purpose This updated (Plan) describes the additional procedures, safeguards and enhanced wastewater treatment measures

More information

Case Study. BiOWiSH Aqua. Biological Help for the Human Race. Municipal Wastewater Bathurst Waste Water Treatment Works Australia.

Case Study. BiOWiSH Aqua. Biological Help for the Human Race. Municipal Wastewater Bathurst Waste Water Treatment Works Australia. Case Study BiOWiSH Aqua Municipal Wastewater Bathurst Waste Water Treatment Works Australia BiOWiSH Aqua Executive Summary The main objective of the validation was to quantify cost savings in using BiOWiSH.

More information

Case Study. Biological Help for the Human Race. Bathurst Municipal Wastewater Treatment Works, New South Wales, Australia.

Case Study. Biological Help for the Human Race. Bathurst Municipal Wastewater Treatment Works, New South Wales, Australia. Case Study BiOWiSH Aqua Bathurst Municipal Wastewater Treatment Works, New South Wales, Australia BiOWiSH Aqua Executive Summary The main objective of the study was to quantify the cost savings of using

More information

Disinfection of Combined Sewer Overflows with Sodium Hypochlorite and Peracetic Acid

Disinfection of Combined Sewer Overflows with Sodium Hypochlorite and Peracetic Acid Disinfection of Combined Sewer Overflows with Sodium Hypochlorite and Peracetic Acid Jay Brady, P.E. March 21, 2012 Global Service Provider Buildings Energy Environment Transportation Water Project Overview

More information

A Sustainable Nitrogen Removal Program using Nitrack Automation at Tyson Foods. Mehran Andalib David Redinger Lee Kleckner Kathryn Chadwick

A Sustainable Nitrogen Removal Program using Nitrack Automation at Tyson Foods. Mehran Andalib David Redinger Lee Kleckner Kathryn Chadwick A Sustainable Nitrogen Removal Program using Nitrack Automation at Tyson Foods Mehran Andalib David Redinger Lee Kleckner Kathryn Chadwick Introduction: This presentation will provide a look at how an

More information

HIGH RATE TREATMENT AS PART OF THE SOLUTION FOR WET WEATHER FLOWS JUNE

HIGH RATE TREATMENT AS PART OF THE SOLUTION FOR WET WEATHER FLOWS JUNE City of Newark, Ohio HIGH RATE TREATMENT AS PART OF THE SOLUTION FOR WET WEATHER FLOWS JUNE 22, 2011 High Rate Treatment Tanks/UV Wet Weather Screen Building JC2/Wet Weather Pump Station Wet Weather Control

More information

TABLE OF CONTENTS. SECTION 1 INTRODUCTION 1.1 Background Purpose and Scope

TABLE OF CONTENTS. SECTION 1 INTRODUCTION 1.1 Background Purpose and Scope TABLE OF CONTENTS Page EXECUTIVE SUMMARY... ES-1 SECTION 1 INTRODUCTION 1.1 Background... 1-1 1.2 Purpose and Scope... 1-2 SECTION 2 HYDRAULIC AND PROCESS ASSESSMENT 2.1 Data Gathering and Analysis...

More information

Optimizing Water Reclamation Systems by Automation using Continuous Water Quality Analysis

Optimizing Water Reclamation Systems by Automation using Continuous Water Quality Analysis Optimizing Water Reclamation Systems by Automation using Continuous Water Quality Analysis Standards Certification Education & Training Publishing Conferences & Exhibits Speakers: Vickie G. Olson, Honeywell

More information

Review of WEFTEC 2016 Challenge & Overview of 2017 Event. Malcolm Fabiyi, PhD, MBA Spencer Snowling, PhD. P.Eng

Review of WEFTEC 2016 Challenge & Overview of 2017 Event. Malcolm Fabiyi, PhD, MBA Spencer Snowling, PhD. P.Eng Review of WEFTEC 2016 Challenge & Overview of 2017 Event Malcolm Fabiyi, PhD, MBA Spencer Snowling, PhD. P.Eng Agenda Review 2016 Challenge Provide overview of updates to 2017 event Frequency WEFTEC Scores

More information

Dundalk Wastewater Treatment Plant

Dundalk Wastewater Treatment Plant Township of Southgate Dundalk Wastewater Treatment Plant 2016 Annual Report Jim Ellis Public Works Manager Dundalk Wastewater Treatment Plant 2016 Annual Report Table of Contents Wastewater Treatment Plant

More information

REMOVAL OF SELENIUM FROM REFINERY WASTEWATER USING THE HONEYWELL UOP XCEED BIOREACTOR SYSTEM

REMOVAL OF SELENIUM FROM REFINERY WASTEWATER USING THE HONEYWELL UOP XCEED BIOREACTOR SYSTEM REMOVAL OF SELENIUM FROM REFINERY WASTEWATER USING THE HONEYWELL UOP XCEED BIOREACTOR SYSTEM Lori C. Donovan, R.E. Hanson, William Sheridan & F. Stephen Lupton Honeywell UOP UOP Industrial Wastewater Technologies

More information

2017 Annual Performance Report

2017 Annual Performance Report Newcastle Water Pollution Control Plant The Regional Municipality of Durham Newcastle Water Pollution Control Plant Environmental Compliance Approval (ECA): 3-2189-87-946 Dated July 26, 1994 Amendments:

More information

ENHANCED TECHNICAL ASSISTANCE EVALUATION

ENHANCED TECHNICAL ASSISTANCE EVALUATION BUREAU OF POINT AND NON-POINT SOURCE MANAGEMENT ENHANCED TECHNICAL ASSISTANCE EVALUATION Big Run Area Municipal Authority Sewage Treatment Plant Henderson Township, Jefferson County NPDES #PA0223107 The

More information

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT ABSTRACT C. Yang*, L. Zhou**, W. Luo***, and L. Johnson**** *Corstar International Corp. 111

More information

Georgia Power Plant McManus NPDES Permit No. GA Ash Pond Dewatering Plan. Revised April 2018

Georgia Power Plant McManus NPDES Permit No. GA Ash Pond Dewatering Plan. Revised April 2018 Georgia Power Plant McManus NPDES Permit No. GA0003794 Revised April 2018 Purpose This (Plan) describes the procedures, safeguards and enhanced wastewater treatment measures that Georgia Power Company

More information

6.2.1 Intermediate Pumping Overview

6.2.1 Intermediate Pumping Overview 6.2.1 Intermediate Pumping Overview The intermediate pumps are the feed pumps to the MBR system. The pumps take flow from the primary effluent channel and pump it to the channel in front of the fine screens.

More information

UV Disinfection for a Municipal Wastewater Lagoon Effluent No Prior Filtration Needed? Wayne Wong, M.A.Sc., P.Eng., PMP

UV Disinfection for a Municipal Wastewater Lagoon Effluent No Prior Filtration Needed? Wayne Wong, M.A.Sc., P.Eng., PMP UV Disinfection for a Municipal Wastewater Lagoon Effluent No Prior Filtration Needed? Wayne Wong, M.A.Sc., P.Eng., PMP Acknowledgements 2 Northern Rockies Regional Municipality Northern Rockies Engineering

More information

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND Brett T. Messner, PE, Tetra Tech, Inc., 201 E Pine St, Suite 1000, Orlando, FL 32801 Brett.Messner@tetratech.com, Ph: 239-851-1225 Fred

More information

Operation and Control of Multiple BNR Processes in One WWTP

Operation and Control of Multiple BNR Processes in One WWTP Operation and Control of Multiple BNR Processes in One WWTP CENTRAL PLANT Williamsport Sanitary Authority s Chesapeake Bay and CSO Compliance Program Presented by: Phil Anderson 1 June 24, 2015 Purpose

More information

Baltimore City Department of Public Works

Baltimore City Department of Public Works Baltimore City Department of Public Works Back River WWTP Process and Construction Overview Michael F. Gallagher, Chief Wastewater Facilities Division Wastewater Treatment Chesapeake Bay Restoration Water

More information

The City of West Palm Beach (City)

The City of West Palm Beach (City) FWRJ Pioneering Ultraviolet Treatment of Potable Water From High-Organic Surface Water in Florida Gabe Maul, GJ Schers, Poonam Kalkat, and Scott Kelly The City of West Palm Beach (City) plans to upgrade

More information

BRACEBRIDGE WASTEWATER TREATMENT 2016 SUMMARY REPORT

BRACEBRIDGE WASTEWATER TREATMENT 2016 SUMMARY REPORT BRACEBRIDGE WASTEWATER TREATMENT 2016 SUMMARY REPORT ENVIRONMENTAL COMPLIANCE APPROVAL: 6801-7VKNAQ ENVIRONMENTAL COMPLIANCE APPROVAL: 6222-AFGSNY (Dec 16 2016) INTRODUCTION The Lagoon Lane Wastewater

More information

On-Line Nutrient Monitoring-Operator s Job Got Easier

On-Line Nutrient Monitoring-Operator s Job Got Easier On-Line Nutrient Monitoring-Operator s Job Got Easier Viraj desilva, PhD, PE, BCEE American Structurepoint, Inc. June 24, 2015 2015 OWEA Conference - Sandusky, Ohio 1 Presentation Outline Introduction

More information

ULTRAVIOLET DISINFECTION 2013 Municipal Markets.

ULTRAVIOLET DISINFECTION 2013 Municipal Markets. ULTRAVIOLET DISINFECTION 2013 Municipal Markets www.glascouv.com Glasco Timeline 1940 s NYC based industrial manufacturer - pharmaceutical and food grade stainless steel fabricator 1960 s - Added Industrial

More information

Treatability Study and Reverse Osmosis Pilot Study of Industrial Wastewater at a Wood Products Mill

Treatability Study and Reverse Osmosis Pilot Study of Industrial Wastewater at a Wood Products Mill Treatability Study and Reverse Osmosis Pilot Study of Industrial Wastewater at a Wood Products Mill NC AWWA-WEA 2017 Annual Conference Randall Foulke, PE, BCEE, LEED AP Tracey Daniels, EI November 14,

More information

City of Leadwood Wastewater System Engineering Report

City of Leadwood Wastewater System Engineering Report City of Leadwood Wastewater System Engineering Report DRAFT H2O C Engneering www.h2oc.com 877-22-WATER Background The purpose of this report is to describe the City of Leadwood s wastewater system (System

More information

EHS SMART-Treat Onsite Moving Media Treatment System

EHS SMART-Treat Onsite Moving Media Treatment System EHS SMART-Treat Onsite Moving Media Treatment System Sampling &Testing Protocol for SMART-Treat Wastewater Treatment System SAMPLING DURING OPERATION OF THE TREATMENT SYSTEM-IF DESIRED Sampling and analytical

More information

75 th STREET WASTEWATER TREATMENT PLANT UPGRADES PROJECT

75 th STREET WASTEWATER TREATMENT PLANT UPGRADES PROJECT 75 th STREET WASTEWATER TREATMENT PLANT UPGRADES PROJECT Basis of Design Memorandum Design Memo No.: DM-7 (REVISED) Date: February 2005 Project/Task: 124487.001.420 Subject: Prepared by: Reviewed by: Hydraulic

More information

Wastewater Treatment. Where does wastewater go when it leaves your house?

Wastewater Treatment. Where does wastewater go when it leaves your house? Wastewater Treatment Where does wastewater go when it leaves your house? Let s s take a look The process includes: Collection of wastewater Primary Treatment Secondary Treatment Solids Handling Influent

More information

A COMPARATIVE PERFORMANCE STUDY OF TWO TYPES OF CLOTH FILTER MEDIA APPLIED IN MUNICIPAL WASTEWATER TREATMENT

A COMPARATIVE PERFORMANCE STUDY OF TWO TYPES OF CLOTH FILTER MEDIA APPLIED IN MUNICIPAL WASTEWATER TREATMENT A COMPARATIVE PERFORMANCE STUDY OF TWO TYPES OF CLOTH FILTER MEDIA APPLIED IN MUNICIPAL WASTEWATER TREATMENT Hui Lin, P.E., Matthew Castillo, Lloyd W. Johnson, P.E., MPD Aqua-Aerobic Systems, Inc., 6306

More information

Anderson Water Pollution Control Plant

Anderson Water Pollution Control Plant City of Anderson Wastewater Division Public Works Director Jeff Kiser Chief Plant Operator Plant Supervisor Operator III Operator I Phil DeBlasio Mike Hansen Tony Hinchliff Vacant Collections Supervisor

More information

Altoona Westerly Wastewater Treatment Facility BNR Conversion with Wet Weather Accommodation

Altoona Westerly Wastewater Treatment Facility BNR Conversion with Wet Weather Accommodation Pennsylvania Water Environment Federation PennTEC Annual Technical Conference June 4, 2013 Altoona Westerly Wastewater Treatment Facility BNR Conversion with Wet Weather Accommodation Presented by: Jim

More information

NPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER

NPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER NPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER Nathan Schmaus, P.E. *, Joseph Viciere, P.E., BCEE, CDM Smith CDM Smith, 1715 North Westshore Boulevard,

More information

National Pollutant Discharge Elimination System; Determination of Sampling Frequency Formula for Industrial Waste Discharges

National Pollutant Discharge Elimination System; Determination of Sampling Frequency Formula for Industrial Waste Discharges Permit Guidance 2 Final National Pollutant Discharge Elimination System; Determination of Sampling Frequency Formula for Industrial Waste Discharges Rule reference: OAC 3745-33 Ohio EPA, Division of Surface

More information

WEFTEC.06. **Cobb County Water System, Marietta, Georgia

WEFTEC.06. **Cobb County Water System, Marietta, Georgia CHEMICALLY ENHANCED PRIMARY TREATMENT FOR A LARGE WATER RECLAMATION FACILITY ON A CONSTRICTED SITE - CONSIDERATIONS FOR DESIGN, START-UP, AND OPERATION ABSTRACT Jeffrey A. Mills, P.E., BCEE,* Roderick

More information

Non-Chemical Disinfection & Dechlorination to Protect RO and Demineralizer Treated Boiler Make-up Water

Non-Chemical Disinfection & Dechlorination to Protect RO and Demineralizer Treated Boiler Make-up Water Non-Chemical Disinfection & Dechlorination to Protect RO and Demineralizer Treated Boiler Make-up Water Dennis Bitter and Ytzhak Rozenberg ABSTRACT Chlorine and biocides have traditionally been used to

More information

ECO Smart Aerobic Waste Water Treatment System. Optimising the re-use and recycling of waste water

ECO Smart Aerobic Waste Water Treatment System. Optimising the re-use and recycling of waste water Optimising the re-use and recycling of waste water The ECO Smart aerobic wastewater treatment system is a selfcontained wastewater treatment system that utilizes a combination of anaerobic as well as aerobic

More information

Hānai Ai / The Food Provider September October November 2014

Hānai Ai / The Food Provider September October November 2014 Evaluation of Various Pathogen Remediation Strategies for Soil and Soilless Farming Systems in Anticipation of the New Food Safety Guidelines J. Uyeda, J. Sugano, S. Fukuda, and J. Odani Agriculture water

More information

Chlorination/Dechlorination: An Environmental Solution

Chlorination/Dechlorination: An Environmental Solution Chlorination/Dechlorination: An Environmental Solution Presented at the 1996 IBC USA Conferences by GERALD F. CONNELL, Capital Controls Company, Inc., Colmar, PA SUMMARY: The topic of this presentation

More information

Iroquois Wastewater Treatment Plant 2016 Annual Performance Report

Iroquois Wastewater Treatment Plant 2016 Annual Performance Report Iroquois Wastewater Treatment Plant 2016 Annual Performance Report The Iroquois WWTP is a Class II wastewater treatment facility owned and operated by the Municipality of South Dundas. Raw sewage is conveyed

More information

2017 Performance Report for Bobcaygeon Waste Water Treatment Facility

2017 Performance Report for Bobcaygeon Waste Water Treatment Facility 2017 Performance Report for Bobcaygeon Waste Water Treatment Facility Amended Environmental Certificate of Approval (ECA) #3028-AEUKDQ Section 11(4) requires the Performance Reports to contain the following:

More information

City of Andover, Kansas Energy Assessment-Wastewater Treatment Plant

City of Andover, Kansas Energy Assessment-Wastewater Treatment Plant City of Andover, Kansas Energy Assessment-Wastewater Treatment Plant April 7, 2014 Prepared by Jerry Blain, P.E., Project Associate Environmental Finance Center Funding for this Energy Assessment was provided

More information

City of Elk River Wastewater Treatment Facility Improvements. Achieving Wastewater Treatment Goals

City of Elk River Wastewater Treatment Facility Improvements. Achieving Wastewater Treatment Goals City of Elk River Wastewater Treatment Facility Improvements Achieving Wastewater Treatment Goals By Tejpal Bala, P.E. Bolton & Menk, Inc. The City of Elk River received a new NPDES permit and the existing

More information

Marcos Elizondo Vice President, Landfill Operations & Engineering

Marcos Elizondo Vice President, Landfill Operations & Engineering Finding A Better Way Marcos Elizondo Vice President, Landfill Operations & Engineering melizondo@wcamerica.com www.wcawaste.com Brad Granley, PE President / Founder bgranley@leachate.us 720-556-4801 www.leachate.us

More information

VC Series Wastewater. Vertical Open Channel Ultraviolet Disinfection

VC Series Wastewater. Vertical Open Channel Ultraviolet Disinfection VC Series Wastewater Vertical Open Channel Ultraviolet Disinfection VC Series dour Company Glasco has been manufacturing UV disinfection systems for over 50 years. Equipment is manufactured for a variety

More information

AMPC Wastewater Management Fact Sheet Series Page 1

AMPC Wastewater Management Fact Sheet Series Page 1 Nitrogen removal Nitrogen present in meat processing wastewater are termed a nutrient, since they are essential elements for life. They largely derive from proteins dissolved into wastewater from meat

More information

AMPC Wastewater Management Fact Sheet Series Page 1

AMPC Wastewater Management Fact Sheet Series Page 1 Nitrogen removal Nitrogen present in meat processing wastewater are termed a nutrient, since they are essential elements for life. They largely derive from proteins dissolved into wastewater from meat

More information

Case Study. BioMagic. Variable Dosing Yields Economy and Results CITY OF CARLSBAD. Pump station odor and hydrogen sulfide control

Case Study. BioMagic. Variable Dosing Yields Economy and Results CITY OF CARLSBAD. Pump station odor and hydrogen sulfide control Case Study Industry: Problem: Municipal Wastewater Pump station odor and hydrogen sulfide control Variable Dosing Yields Economy and Results Business Overview The Carlsbad Municipal Water District is a

More information

Taylor Creek Treatment Plant. Metropolitan Sewer District of Greater Cincinnati

Taylor Creek Treatment Plant. Metropolitan Sewer District of Greater Cincinnati Taylor Creek Treatment Plant Metropolitan Sewer District of Greater Cincinnati Who is this guy and what is he talking about? Brad Blankenship Taylor Creek Operator 3.5 years MSD Operator 5.5 years (total)

More information

Clean Water 2020 Program

Clean Water 2020 Program Clean Water 2020 Program WWTP OPERATIONS PROGRAM Updated December 2015 Table of Contents WWTP Operations Program 2015 List of Tables... 2 Program Summary and Intent... 3 Operations Plan... 3 Process Control

More information

EQUIPMENT AND SERVICE COMPANY, INCORPORATED FX- 300 ISE Ammonia, Nitrate, Nitrite Measurement

EQUIPMENT AND SERVICE COMPANY, INCORPORATED FX- 300 ISE Ammonia, Nitrate, Nitrite Measurement FX-300 Online Ammonia, Nitrate, Nitrite Monitor and Controller The Foxcroft FX-300 with ion selective electrode technology can be used as an online monitor and control method for Ammonium (NH4+), Ammonia

More information

Copies: Mark Hildebrand (NCA) ARCADIS Project No.: April 10, Task A 3100

Copies: Mark Hildebrand (NCA) ARCADIS Project No.: April 10, Task A 3100 MEMO To: Jeff Pelz (West Yost) Kathryn Gies (West Yost) Copies: Mark Hildebrand (NCA) ARCADIS U.S., Inc. 200 Harvard Mills Square Suite 430 Wakefield Massachusetts 01880 Tel 781 224 4488 Fax 781 224 3033

More information

NEW SOLUTION FOR PRIMARY WASTEWATER TREATMENT; CLOTH MEDIA FILTRATION

NEW SOLUTION FOR PRIMARY WASTEWATER TREATMENT; CLOTH MEDIA FILTRATION NEW SOLUTION FOR PRIMARY WASTEWATER TREATMENT; CLOTH MEDIA FILTRATION Introduction John D. Dyson*, Aqua Aerobic Systems, Inc. 636 N. Alpine Rd, Loves Park, IL jdyson@aqua-aerobic.com Primary and Primary

More information

Post-Aerobic Digester with Bioaugmentation Pilot Study City of Meridian, ID WWTP PNCWA 2010

Post-Aerobic Digester with Bioaugmentation Pilot Study City of Meridian, ID WWTP PNCWA 2010 Post-Aerobic Digester with Bioaugmentation Pilot Study City of Meridian, ID WWTP by: William Leaf Adrienne Menniti Bruce Johnson CH2M HILL, Inc. Clint Dolsby Tracy Crane City of Meridian October 26, 21

More information

Aeration Blower Requirements. Tom Jenkins 06/15/2016

Aeration Blower Requirements. Tom Jenkins 06/15/2016 Aeration Blower Requirements Tom Jenkins 06/15/2016 Aeration blowers receive a lot of attention from design engineers, suppliers, and end users. That is understandable since blowers account for more than

More information

Bracebridge Wastewater Treatment 2017 Summary Report

Bracebridge Wastewater Treatment 2017 Summary Report Bracebridge Wastewater Treatment 2017 Summary Report Environmental Compliance Approval: 6222-AFGSNY (Dec 16 2016) INTRODUCTION The Lagoon Lane Wastewater Treatment Plant is owned and operated by the District

More information

Stonecrest Estates Sewage Treatment Plant 2017 Annual Report

Stonecrest Estates Sewage Treatment Plant 2017 Annual Report 2017 Stonecrest Estates Sewage Treatment Plant 2017 Annual Report The Corporation of the City of Quinte West 0 Contents Table of Figures... 1 Executive Summary... 3 Summary and Interpretation of Monitoring

More information

Membrane BioReactor: Technology for Waste Water Reclamation

Membrane BioReactor: Technology for Waste Water Reclamation Membrane BioReactor: Technology for Waste Water Reclamation Sachin Malekar - Senior Manager, Technology & Nilesh Tantak - Executive, Technology Ion Exchange (India) Ltd. BACKGROUND Due to diminishing water

More information