Media Fill Test Kits USP <797> COMPLIANT. HARDY DIAGNOSTICS. Low Risk. Medium Risk. High Risk
|
|
- Erick Eaton
- 6 years ago
- Views:
Transcription
1 HARDY DIAGNOSTICS Media Fill Test Kits USP <797> COMPLIANT Low Risk Medium Risk High Risk Validate the proficiency of your technicians and pharmacists per USP <797> Test for sterility per USP <71> ss
2 Compliance was never so easy! Microbial Contamination Testing for CSPs Hardy Diagnostics offers all the products you need to easily assess the risk of microbial contamination of your CSPs (Compounded Sterile Preparations) according to the USP, Chapter <797>. One kit supplies what is needed to test the proficiency of one technician or pharmacist. Kits are available for low, medium, and high risk procedures. Components are in a selfcontained ready-to-use kit. A results log sheet is included in each kit. Detailed instructions and diagrams are included with each kit. Expert technical support is available from our staff of microbiologists. Kits are designed to help you follow USP <797> guidelines. Surface Sampling Air Sampling Sterility Tests 2 A Culture of Service
3 Media Fill Test Kits Low-Risk Level Kit Contents 1 x 100ml Sterile Tryptic Soy Broth Vial 3 x 20ml Empty Sterile Vials 1 x Write-on Whirl-Pak Bag 1 x Results Log Sheet Cat. no. HVL1 Procedure Summary from USP <797> Aseptically transfer Tryptic Soy Broth to empty sterile vials using a sterile 10ml syringe. Attach sterile adhesive seals. Incubate at 25 ºC to 35 ºC. Examine for turbidity at end of 14 days. 4 transfers of each 100ml Sterile Tryptic Soy Broth Vial 20ml vial 20ml vial 20ml vial *Syringe(s), needle(s), and adhesive seals not included. Whirl-Pak is a registered trademark of Nasco Industries, Inc. Sales@HardyDiagnostics.com Fax: Ph:
4 Medium-Risk Level Comprehensive Media Fill Test Kits Kit Contents 1 x 700ml Sterile Tryptic Soy Broth Bag 6 x 12 Empty Sterile Bags 6 x 20ml Empty Sterile Vials 1 x Write-on Whirl-Pak Bag 1 x Results Log Sheet Cat. no. HVM1 Utilizes procedures that closely represent typical complex manipulations used to compound medium-risk level preparations as described in USP <797>. Procedure Summary from USP <797> Aseptically transfer 100ml Sterile Tryptic Soy Broth to empty sterile bags using gravity tubing. Transfer Tryptic Soy Broth between bags, using a sterile 10ml syringe. Aseptically transfer Tryptic Soy Broth to small empty sterile vials Attach sterile adhesive seals. Incubate at 25 ºC to 35 ºC. Examine for turbidity at end of 14 days. 700ml Sterile Tryptic Soy Broth Bag 100ml 100ml 100ml 100ml 100ml 100ml Three transfers using syringe Three transfers using syringe Three transfers using syringe *Syringe(s), needle(s), and adhesive seals not included. Whirl-Pak is a registered trademark of Nasco Industries, Inc. 4 A Culture of Service
5 Media Fill Test Kits Medium-Risk Level-Basic Low Cost Medium-Risk Kit, fulfills minimum requirements Kit Contents 3 x 50ml Serum Vial Sterile Tryptic Soy Broth (TSB) 6 x 50ml Serum Vial (empty), sterile 3 x 20ml Serum Vials (empty), sterile 1 x Write-on Whirl-Pak Bag 1 x Results Log Sheet Cat. no. HVM2 Meets basic requirements for medium-risk challenge testing. Procedure Summary 1 2 Aseptically transfer two aliquots of approximately 2 of sterile Tryptic Soy Broth into each of the empty sterile 50ml vials using tubing. Repeat this process with fresh tubing two more times so that there will be six 50ml vials containing 2 of test medium. Transfer Tryptic Soy Broth between empty vials, using a sterile 10ml syringe and 18-gauge needle Apply sterile adhesive seals aseptically to the rubber closures once the vials have been filled. Incubate the vials at 20 ºC to 25 ºC and/ or 30 ºC to 35 ºC for 14 days. Examine for turbidity. Record results on the Results Log Sheet. 3 Aseptically transfer Tryptic Soy Broth to small empty sterile vials using a sterile 10ml syringe and vented needle ml 50ml 50ml *Syringe(s), needle(s), and adhesive seals not included. Whirl-Pak is a registered trademark of Nasco Industries, Inc. Sales@HardyDiagnostics.com Fax: Ph:
6 Media Fill Test Kits High-Risk Level Kit Contents 1 x 3gm Tryptic Soy Broth Powder (non-sterile) 9 x 20ml Empty Sterile Vials 1 x Write-on Whirl-Pak Bag 1 x Results Log Sheet Cat. no. HVH1 Procedure Summary from USP <797> 1 2 Unscrew cap and add 100ml of water (non-bacteriostatic) to Tryptic Soy Broth powder. Screw on cap and mix Attach sterile adhesive seals. Incubate at 25 ºC to 35 ºC. Examine for turbidity at end of 14 days. 3 Transfer the appropriate amounts of Tryptic Soy Broth to empty sterile vials using a sterile 30ml syringe with and without a 0.2 micron filter. Add 100ml non-bacteriostatic water* to 3 grams Tryptic Soy Broth Powder Screw on cap and mix needle positive control needle positive control needle positive control 10ml 10ml 10ml filter 10ml filter 10ml filter 10ml 6 A Culture of Service *Syringe(s), needle(s), adhesive seals, non-bacteriostatic water, and filters not included. Whirl-Pak is a registered trademark of Nasco Industries, Inc.
7 Environmental Monitoring Air Monitoring Impact Air Sampler USP <797> requires that the number of viable microorganisms in the air environment of the compounding area be evaluated. This test is to be performed at least semi-annually for all risk levels. More frequent sampling will provide earlier detection of loss of environmental control failures. Hardy Diagnostics offers an easy way of accomplishing this using an impact air sampler. Cat. no Impact Air Sampler for Active Air Sampling Spin Air Microbial Sampler This innovative microbiological impact air sampler pulls air in a controlled fashion against the agar plate. The plate rotates during the process to ensure maximum distribution of the microorganism throughout the plate surface. Holds 100mm Petri dishes. The time, airflow, and rotation speed are variable. Carrying case and battery charger included. This unit is computer connectable and bar code compatible. Features Easy to operate Durable Cost effective Holds standard 100mm Petri dish Adjustable-time, air volume, and rotation speeds The unit comes fully calibrated Carrying case and charger included This unit is computer connectable and bar code compatible Each Culture Media for Air Sampling Tryptic Soy Agar (TSA) 15x100mm, 10 plates...g60 Malt Extract Agar (MEA)* Selective for yeast and mold. 15x100mm, 10 plates...w Remove cover from sampler. Install plate in its holder and remove lid from plate. Select settings on Spin Air sampler and press start. Once the cycle is complete, replace lid and incubate TSA º C for hours. After 48 hours, count the number of colonies. Incubate *Malt Extract Agar C for 5-7 days. *MEA Agar is recommended only for High Risk Level compounding environments. Sales@HardyDiagnostics.com Fax: Ph:
8 Environmental Monitoring Surface & Finger Tip Sampling Hardy Diagnostics offers a fast and convenient way to monitor the microbial bioburden of the work surface of your laminar air flow workbench. Contact agar plates are simply pressed onto the surface or glove fingertips, incubated, and colonies are counted. Surface Sampling Surface sampling is required on a periodic basis for each laminar air flow workbench or barrier isolator. Tryptic Soy Agar (P34) 1 Remove lid. 2 Gently press plate to surface without twisting or sliding. 3 Replace lid and incubate at º C. After hours, count the number of colonies. Fingertip Sampling Personnel monitoring (glove fingertips) is required to be done at initial competency evaluation and no less than three times before being allowed to compound sterile preparations. Re-evaluation is required at each media fill challenge test. 1 Remove lid. 2 Gently press glove tips to plate surface. 3 Replace lid and incubate at º C. After hours, count the number of colonies. Record your results. Culture Media for Surface and Finger Tip Sampling Tryptic Soy Agar with Lecithin and Tween 15x60mm, 10 contact plates...p34 Malt Extract Agar (MEA)* 15x60mm, 10 contact plates... P93 Tween is a registered trademark of ICI Americas, Inc. *MEA Agar is recommended only for High Risk Level compounding environments. 8 A Culture of Service
9 D C B A 1 Biological Indicators SporAmpule A Biological Indicator (BI) system ideal for monitoring liquid cycles as well as standard steam sterilization cycles containing Geobacillus stearothermophilus spores. Gives clear, easy-tointerpret results. Purple to yellow color change or visible turbidity of processed ampule indicates sterilizer failure. Final results after 48 hours incubation in any dry block incubator operating at ºC 100/pk... BST100 20/pk... BST MM Dry Block Incubator Heat Block Insert Surface Monitoring Solar-Cult Flex-Paddle Surface Monitoring Slide The surface monitoring slide is simply a two sidded agar coated plastic paddle which is attached to the cap of a shatter-proof, optically clear, colorless plastic vial. To sample a surface, remove the cap/paddle assembly from the vial. Holding cap in hand, press the surface of the paddle gently onto the surface to be tested (paddle will flex to right angles with a gentle pushing motion). Incubate at ºC. After hours, count the number of colonies. Tryptic Soy Agar w/lecithin and Tween 80 on both sides of the paddle, 10/pk...FP400 EnviroTrans Swab Kit Neutralizing Saline (Pre-moistened, ready-to-use) A ready-to-use swab and tube pre-filled with 5 mls of neutralizing saline. Simply remove the cap, which is attached to the Dacron swab. Collect your sample by swabbing the surface, recap, and send to the lab. The solution can be inoculated onto a Tryptic Soy Agar petri plate (Cat. no. G60). Incubate at ºC. After hours, count the number of colonies. Excellent for detection or enumeration of microorganisms from environmental surfaces., 20/box... SRK55 TSA, Cat. no. G60 Sales@HardyDiagnostics.com Fax: Ph:
10 CSP Kits Random Testing Kit Contents 5 x Double Strength Tryptic Soy Broth Syringes 5 x Write-on Whirl-Pak Bags 1 x Results Log Sheet Test to be performed on returned I.V. solutions Cat. no. HVR1 Use on expired or returned drugs to check sterility, for quality assurance purposes only. 1 Attach sterile needle to of sterile double strength Tryptic Soy Broth syringe. 3 4 Incubate at 25 ºC to 35 ºC. Examine for turbidity at end of 14 days. 2 Draw of compounded preparation into the Double Strength Tryptic Soy Broth Syringe. 5 Does not fulfill requirements for USP <71> Sterility Testing. Sterile Double Strength Tryptic Soy Broth Syringe Draw s of drug into the syringe *Sterile needles not included. Whirl-Pak is a registered trademark of Nasco Industries, Inc. 10 A Culture of Service
11 Sterility Testing Direct Inoculation of Pharmaceuticals using Hardy Diagnostics Media <USP 71> Drug solutions can be tested for sterility by direct inoculation into Tryptic Soy Broth (TSB) and Fluid Thioglycollate according to procedures found in <USP 71>. By incubating for 14 days, a lack of fungal, aerobic and anaerobic bacterial contamination can be proven. Please consult <USP 71> (Table II) to verify proper inoculum size and media volume. Below are some some types of media that can be used for direct inoculation. Tryptic Soy Broth, USP Recommended for use as a general purpose medium for the isolation and cultivation of a wide variety of bacteria and fungi. 100ml glass bottle with needle port septum, 100ml fill, 20/pk...U46 Fluid Thioglycollate Broth Medium with Indicator, USP For the cultivation of anaerobic microorganisms. 100ml glass bottle with needle port septum, 100ml fill, 12/pk...U47 Tryptic Soy Broth, USP Recommended for use as a general purpose medium for the isolation and cultivation of a wide variety of bacteria and fungi. 20ml glass bottle with needle port septum, 20ml fill, 50/pk...U38 Fluid Thioglycollate Broth Medium with Indicator, USP For the cultivation of anaerobic microorganisms. 20ml glass bottle with needle port septum, 20ml fill 50/pk...U68 Custom containers and fill volumes are available upon request. Sales@HardyDiagnostics.com Fax: Ph:
12 Sterility Testing - Filtering Sterisart Universal Pump Sterility Testing System The preferred method for sterility testing is the membrane filter method using a closed sterility test system, such as the new disposable sterility test system Sterisart. The Sterisart Universal pump is a peristaltic pump made of stainless steel, and is equipped with appropriate features for attaching a Sterisart sterility test canister. After the Sterisart canisters have been positioned and the sterility test system spike/ needle has been inserted into the sample container, the pump is started. The pump draws liquid from the sample container into the specially designed double tubing, distributing the liquid equally to both Sterisart canisters. Similarly, the pump then flushes the Sterisart canisters with rinse liquid such as Fluid A, (Cat. no. U109). Finally, the pump fills the two Sterisart canisters with culture media, such as Tryptic Soy Broth 100ml, (Cat. no. U46), or Fluid Thioglycollate Medium 100ml, (Cat. no. U47). The Sterisart canisters are then incubated for 14 days. 12 A Culture of Service
13 Sterisart Universal Pump The Sterisart Universal pump can be used in clean rooms, integrated into clean benches, or installed in the work area of isolators. Each Support rod Spring loaded fastening arm for media containers Features and Benefits Closed system decrease the chance of technician contamination. Rugged and maintenance-free. Compact and ergonomic construction. Modular design. Pump available with special software (menu-driven prompts for operator guidance; all process sequences can be logged; barcode recognition). Convenient foot switch activator. Control unit Optional ampoule breaker Sterisart disposable canisters Bottle holding ring Spike/ Needle Pump Clamping lever Pump head Speed selection knob Carrying handle Draining container Draining tube Fax: Ph:
14 Sterisart NF Canisters for Sterility Testing Disposable Sample Canisters and Adapters for use with Sterisart Universal Pump For sterility testing in isolators and clean benches. Individually sterile, double-packaged, gamma irradiated, needles made of stainless steel. Transfer tubing Vent filter Septum Easy-to-read graduated marks Sterisart Canisters can be ordered with or without a needle port septum for sub-culturing of positive results. Pre-installed color-coded tube clamps. Reliable membrane for high retention of microbes VHP resistant packaging. Stainless steel septum needle. Multiple styles available for different applications. Call for product recommendation for your application. 14 A Culture of Service
15 Growth Promotion Testing USP <71> EZ-Accu Shot Select is packaged as a kit containing five Quality Control strains required by the Pharmacopeias for Growth Promotion Testing, all of which are derived from the American Type Culture Collection (ATCC ). Equipment Licensed, traceable strains: Aspergillus brasiliensis ATCC Bacillus subtilis subsp. spizizenii ATCC 6633 Candida albicans ATCC Pseudomonas aeruginosa ATCC 9027 Staphylococcus aureus subsp. aureus ATCC 6538 Kit includes: 1 vial of each microorganism (1 lyophilized pellet per vial) 5 vials of hydrating fluid (1.2 ml in each vial) 5 peel-off labels, one for each strain Each Incubator (Low cost, small foot print) This compact incubator fits easily on most counter tops. The incubator holds a constant temperature to plus or minus one degree. It is made of powder coated steel and has an acrylic see-through door. It comes with two adjustable shelves. Capable of temperatures up to 60 C. Capacity is 0.8 cubic feet. The inside dimensions of the chamber are 13 W x 14 H x D. Each True-Tempe Incubator Thermometers These environmentally safe thermometers contain no dangerous mercury; instead they are filled with red spirit alcohol. For additional safety, they are encased in a Teflon coating to prevent breakage. Range is 18 C to 50 C, with 0.5 C divisions. 135mm in height. The thermometer is sealed within a fluid-filled unbreakable bottle to prevent temperature reading fluctuations, due to the opening and closing of the incubator door. Attached magnet allows for adherence to the inside wall of the incubator. Each...I0301S. Teflon is a registered trademark of DuPont Corp. Sales@HardyDiagnostics.com Fax: Ph:
16 A Culture of Service 1430 West McCoy Lane Santa Maria, CA Santa Maria, CA Olympia, WA Salt Lake City, UT Phoenix, AZ Dallas, TX Springboro, OH Lake City, FL Albany, NY
CONTENT
102517SS C700 CONTENT HardyVAL Introduction 01 HardyVAL and USP 02 HardyVAL Test Kits 03 Media Bags 08 HardyVAL á la carte 10 Air Sampling - TRIO.BAS 12 Media for Air Sampling 13 Media for Surface
More informationHardyVal TM CSP MEDIUM-RISK LEVEL MEDIA-FILL CHALLENGE KITS
HardyVal TM CSP MEDIUM-RISK LEVEL MEDIA-FILL CHALLENGE KITS Cat. no. HVM1 Medium-Risk Level Media-Fill Comprehensive Challenge Test Kit - Bag Each kit contains: Tryptic Soy Broth (TSB), 1000ml Dual Port
More informationHardyVal TM CSP RANDOM TEST KIT
HardyVal TM CSP RANDOM TEST KIT Cat. no. HVR1 Random Test Kit 5 tests/kit INTENDED USE Each kit contains: Tryptic Soy Broth, Double Strength (DS), 12ml Syringe, 5.2ml Whirl-Pak Bag Results Log Sheet 5
More informationGrowth Promotion Test Guide for Media Used in Sterility Tests
Growth Promotion Test Guide for Media Used in Sterility Tests The Sterility Test The purpose of the Sterility Test is to determine if a sample of a pharmaceutical product or component is sterile. A satisfactory
More informationANALYTICAL REPORT: Comparison of the Microbial Recovery Efficacy of QI Medical EnviroTest Paddles versus a Conventional Contact Plate
FOCUS Scientific Services LLC ANALYTICAL REPORT: Comparison of the Microbial Recovery Efficacy of QI Medical EnviroTest Paddles versus a Conventional Contact Plate REPORT: FS-QI-GM-003 Study Manager: Anthony
More informationUSP Chapter <797> & <800> Testing Supplies
How clean are your testing supplies? USP Chapter & Testing Supplies The first aseptic products built to minimize risk starting with the packaging itself Smarter, Cleaner, Convenient Cultivate
More informationIN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing
EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT IN THIS SECTION MICROBIOLOGY TESTING Microbial assays involve a variety of tests, from the determination of the numbers and types of organisms naturally present
More informationMethod Suitability Report Membrane Filtration Sterility Test with QTMicro Apparatus
Method Suitability Report Membrane Filtration Sterility Test with QTMicro Apparatus Bevacizumab (Avastin) 1.25 mg/0.05ml This report provides details on the specifics of a Membrane Filtration Sterility
More informationSterisart BD Media and Fluids One-Stop Shopping for Sterility Testing
Sterisart BD Media and Fluids One-Stop Shopping for Sterility Testing Sterisart Increasing Safety and Reliability Pharmaceuticals, biologicals, medical devices and any material claiming to be sterile must
More informationFinally, You Have a Choice! Online Ordering Available
Simple and Effective System for Colony Counting Finally, You Have a Choice! Online Ordering Available Compact Dry is a ready-touse system reducing the time needed to perform microbial testing on food,
More informationTRYPTIC SOY AGAR (TSA) WITH LECITHIN AND TWEEN 80
TRYPTIC SOY AGAR (TSA) WITH LECITHIN AND TWEEN 80 Cat. no. P45 TSA with Lecithin and Tween 80, 15x60mm Contact Plate, 15ml Cat. no. Q13 TSA with Lecithin and Tween 80, 20x125mm Tube, 18ml Deep Cat. no.
More informationTECHNICAL LEAFLET. MEDI-MEDIA-FILL KIT SUPPLY PACKAGE (Code: MR-25/S)
TECHNICAL LEAFLET MEDI-MEDIA-FILL KIT SUPPLY PACKAGE (Code: MR-25/S) TEST AGAR PLATES FOR PERSONNEL AND ENVIRONMENTAL MICROBIOLOGICAL MONITORING COMPONENTS: Test Agar Plates Data Log Sheet Technical Leaflet
More informationMicroFunnel Filter Funnels
MicroFunnel Filter Funnels Description Increase laboratory efficiency with a newly designed, disposable filter funnel and Petri dish all in one. Certified. Each lot is certified for microbiological analysis
More informationá61ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: MICROBIAL ENUMERATION TESTS
USP 40 Microbiological Tests / á61ñ Microbiological Examination 1 á61ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: MICROBIAL ENUMERATION TESTS INTRODUCTION The tests described hereafter will allow
More informationOverview of a sterility assurance program for PET drugs
Coalition for PET Drug Approval Radiopharmaceutical Sciences Council Overview of a sterility assurance program for PET drugs Eric Webster, PETNET Solutions Disclosures Employee of PETNET Solutions, a Siemens
More informationGuidelines for QualiTru Line Sampling
Guidelines for QualiTru Line Sampling QUALITRU GUIDELINES FOR LINE SAMPLING 1. Purpose: Following these Standard Operating Procedures, farms and processing plants may use the QualiTru aseptic sampling
More informationNew York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765
New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765 Division of Environmental Health Sciences Albany, New York NYS DOH LEB-608 Identification
More informationTECHNICAL DATASHEET. in compliance with: USP, ISO and all appropriate subsections FQ 106 v3.0 August, 2015
ETIGAM TECHNICAL DATASHEET ETIGAM NSS biological indicator spore strips for radiation Bacillus pumilus This technical report provides relevant data and instructions for use of the NSS biological indicator
More informationStandard Operating Procedure Title: Stock Suspensions of Micro-Organisms
2. Correct Aseptic technique must be used when performing all Microbiological procedures. 3. All work must be carried out in the Biohazard Cabinet. Table of Contents 2. Positive Identification of Reference
More informationValidation Guide Sterisart NF
Validation Guide Sterisart NF Validation Guide Sterisart NF Version 1.0 Disposable Filtration Units for Sterility Testing 16466-ACD -GBD 16467-ACD -GBD 16468-ACD -GBD 16469 16470 16475-GBD Table of Contents
More informationNew York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765
New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765 Division of Environmental Health Sciences Albany, New York NYS DOH LEB-610 Identification
More informationLABORATORY #2 -- BIOL 111 BACTERIAL CULTIVATION & NORMAL FLORA
LABORATORY #2 -- BIOL 111 BACTERIAL CULTIVATION & NORMAL FLORA OBJECTIVES After completing this exercise you should be able to: 1. Identify various types of media 2. Isolate bacteria using aseptic technique.
More informationHeterotrophic Bacteria
, m-hpc, 8242 DOC316.53.01225 Pour Plate Method Method 8242 m-hpc Scope and Application: For water and wastewater. Test preparation Introduction Before starting the test: The Pour Plate Method, also known
More informationValidation Guide Sterisart NF
Validation Guide Sterisart NF Validation Guide Sterisart NF Version 1.0 Disposable Filtration Units for Sterility Testing 16466-ACD -GBD 16467-ACD -GBD 16468-ACD -GBD 16469 16470 16475-GBD Table of Contents
More informationASEPTIC TRANSFER & PURE CULTURE TECHNIQUES
ASEPTIC TRANSFER & PURE CULTURE TECHNIQUES GENERAL GUIDELINES & REMINDERS: SAFETY: NO EATING OR DRINKING IN THE LAB! Wash your hands with soap both BEFORE and AFTER lab, and, in addition, when you have
More informationTRANSFER OF BACTERIA USING ASEPTIC TECHNIQUE
TRANSFER OF BACTERIA USING ASEPTIC TECHNIQUE GENERAL GUIDELINES: Safety Wear a lab coat and have your goggles on! ALWAYS disinfect the tables BEFORE and AFTER lab. Wash your hands with soap both BEFORE
More informationUNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS
DEPARTMENT OF VETERANS AFFAIRS Veterans Health Administration Washington DC 20420 IL 10-2006-008 In Reply Refer To: 10NB UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL
More informationMicroorganisms In Our Environment
PR015 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Microorganisms In Our Environment Teacher s Guidebook (Cat. # BE 106) think proteins!
More informationAssessment of Antibacterial Efficacy of Goldshield against MRSA and VRE
Assessment of Antibacterial Efficacy of against MRSA and VRE Sheri Maxwell, B.S. Charles P. Gerba, Ph.D. Department of Soil, Water and Environmental Science University of Arizona Tucson, Arizona. 85721
More informationQuality Control Microorganism Product Guide. Convenience with Confidence
Quality Control Microorganism Product Guide Convenience with Confidence LYFO DISK For Culture Purposes and Quality Control Applications LYFO DISK lyophilized pellets contain a single microorganism strain
More informationSanitization and endotoxin clearance in AxiChrom columns
Application note 8-990-4 AE Chromatography columns Sanitization and endotoxin clearance in AxiChrom columns Columns used in cgmp environments need to maintain very high standards of hygiene. AxiChrom chromatography
More informationDisinfectant Qualification A Multifaceted Study
Disinfectant Qualification A Multifaceted Study In this article, Ziva Abraham, Microrite, Inc., gives us a brief overview of the disinfectant qualification study process. An effective cleaning and disinfection
More informationINSTRUCTIONS FOR USE
INSTRUCTIONS FOR USE INTENDED USE KWIK-STIK, KWIK-STIK Plus and LYFO DISK microorganisms are intended to be used as controls to verify the performance of assays, reagents or media that are intended to
More informationStudy Summary. Results: All tested media-filled vials were negative for growth of any microorganisms.
A 7 Days Microbial Ingress Test of Single Use Vials Utilizing the EQUASHIELD Closed System Drug Transfer Device Study by Nelson Laboratories (Salt Lake City, UT) 2013, updated in 2014* Study Summary Abstract:
More informationFinal text for addition to The International Pharmacopoeia
March 2012 3.3.1 MICROBIOLOGICAL EXAMINATION OF NON-STERILE PRODUCTS: MICROBIAL ENUMERATION TESTS Final text for addition to The International Pharmacopoeia This monograph was adopted at the Forty-sixth
More informationNew York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765
New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765 Division of Environmental Health Sciences Albany, New York NYS DOH LEB-612 Identification
More information3.2 Test for sterility
This text is based on the internationally-harmonized texts developed by the Pharmacopoeial Discussion Group (PDG). Some editorial modifications have been made in order to be in line with the style used
More informationToday s Topics. General Quality Control Best Practices. Practices Antimicrobial Effectiveness Testing(AET) Best Practices Environmental Isolates
Laboratory Best Practices in QC Microbiology Today s Topics General Quality Control Best Practices Growth Promotion Testing (GPT) Best Practices Antimicrobial Effectiveness Testing(AET) Best Practices
More informationNew York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765
New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765 Division of Environmental Health Sciences Albany, New York NYS DOH LEB-606 Identification
More informationNew York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765
New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765 Division of Environmental Health Sciences Albany, New York NYS DOH LEB-607 Identification
More information3.3.1 Microbial enumeration tests
This text is based on the internationally-harmonized texts developed by the Pharmacopoeial Discussion Group (PDG). Some editorial modifications have been made in order to be in line with the style used
More informationEnvironmental Monitoring of Aseptic Processing Areas - 2
Environmental Monitoring of Aseptic Processing Areas - 2 A war against an invisible enemy DCVMN - Víctor Maqueda - May 30, 31, June 1 2016 1 Active Air Monitoring (Viables) Air Sieve Samplers Draw air
More informationTests to Support Sterility Claim. Imtiaz Ahmed
Tests to Support Sterility Claim Imtiaz Ahmed Sterile Product As per TGO 77, a sterile product must comply with the requirements of the following tests: Sterility Test Bacterial Endotoxins Test Appendix
More informationFiltration Microbiology
Membrane Filtration Microbiology Online Ordering Available 082313ss Table of Contents 2 Sterility Testing 2 Sterisart Universal Pump 4 Sterisart NF Canisters 10 Membrane Filtration 10 Combisart Filter
More informationBiocidal Surface Test - Clinell Wipes ~ Project Report Prepared for GAMA Healthcare Ltd ~ Huddersfield Microbiology Services Oct 06
Biocidal Surface Test - Clinell Wipes ~ Project Report Prepared for GAMA Healthcare Ltd ~ Huddersfield Microbiology Services Oct 06 Summary The ability of Clinell wipes to disinfect contaminated steel
More informationThe Effect of Air Pockets on the Efficiency of Disinfection of Respiratory Equipment by Pasteurization
CENORIN MEDICAL INFORMATION SERIES The Effect of Air Pockets on the Efficiency of Disinfection of Respiratory Equipment by Pasteurization Performed by: Bio Research Laboratories, Inc. Cenorin, LLC 6324
More informationCritical Environment Products and Services
Critical Environment Products and Services For over two decades, EP Scientific products and services have defined clean for environmental sampling containers and services. Our proprietary cleaning methods
More informationPharmaceutical Microbiology
Pharmaceutical Microbiology Manufactured by Online Ordering Available Table of Contents 1 Agar Plates for Membrane Filtration and Mycoplasma Culturing 2 Prepared Culture Media Plates and Tubes 4 Bottle
More informationSolutions for All Your Aseptic Parenteral Drug Formulation/Filling Needs. BUBBLE-FREE FILLING : A New Option in Prefilled Syringe Filling
WHITEPAPER Hyaluron Contract Manufacturing Solutions for All Your Aseptic Parenteral Drug Formulation/Filling Needs BUBBLE-FREE FILLING : A New Option in Prefilled Syringe Filling Introduction The advent
More informationCleaning Efficiency of The MicroOne Wipe and Mop Cleaning System
PDA Laboratories, Inc. A Contract ing Laboratory Visit us at www.pdalabsinc.com 17A Kiel Avenue Kinnelon, NJ 07405 (Tel) 973-492-8000 (Fax) 973-492-8002 pdainfo@pdalabsinc.com Cleaning Efficiency of The
More informationMicrobial Media and Culture Dishes
Microbial Media and Culture Dishes Microbial Media and Culture Dishes Culture Media...512 Petri Dishes and Petri-Pad Dishes...514 Pad Dispenser...514 PetriSlides Dish...515 Swabs and Samplers...515 PROCESS
More informationCLENDO INDUSTRIAL LABORATORY. CUSTOMER SAMPLE ANALYSIS REPORT Page1 of 8. FDA No CLENDO CONTROL NO. 9081, 9095
CUSTOMER SAMPLE ANALYSIS REPORT Page1 of 8 A. CUSTOMER NAME TECHNICAL SALES INC. B. CLIENT NUMBER 548 C. ADDRESS HC-1 BOX 23223 CAGUAS, PR 725-8918 D. TELEPHONE (787) 272-3345 E. FAX (787) 272-3191 F.
More informationSanitization of ÄKTA pilot 600 using sodium hydroxide
GE Healthcare Sanitization of ÄKTA pilot 600 using sodium hydroxide The ÄKTA pilot 600 chromatography system is designed to facilitate sanitization, with the high standards imposed by regulatory authorities
More information2.1 Tryptone Soya Broth containing 4% Tween 80 (TSB + T), or another appropriate deactivating broth.
Prepared by: Date: Supersedes: Checked by: Date: Date Issued: Approved by: Date: Review Date: 1. SCOPE AND APPLICATION This general test method applies to the determination of microbiological test method
More informationNew York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765
New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765 Division of Environmental Health Sciences Albany, New York NYS DOH LEB-606 Identification
More informationActero Salmonella/STEC Enrichment Media Product Information
Actero Salmonella/STEC Enrichment Media Product Information INTENDED USE: Actero Salmonella/STEC Enrichment Media is a selective medium optimized for an improved enrichment of Salmonella spp. from food
More informationGuidelines for sampling and maintenance of the QualiTru Side Mount Truck Sampler
Guidelines for sampling and maintenance of the QualiTru Side Mount Truck Sampler QUALITRU HAULER TRUCK MOUNT SIDE SAMPLER 1. Purpose In an effort to increase the security, health and safety to haulers
More informationINSTRUCTIONS FOR USE LYFO DISK KWIK-STIK KWIK-STIK PLUS. n LYFO DISK Microorganisms n KWIK-STIK Microorganisms n KWIK-STIK Plus Microorganisms
INSTRUCTIONS FOR USE n LYFO DISK Microorganisms n KWIK-STIK Microorganisms n KWIK-STIK Plus Microorganisms LYFO DISK INTENDED USE LYFO DISK, KWIK-STIK and KWIK-STIK Plus Microorganisms are lyophilized,
More informationActero Salmonella Enrichment Media Product Information
Actero Salmonella Enrichment Media Product Information INTENDED USE: Actero Salmonella Enrichment Media is a selective medium optimized for an improved enrichment of Salmonella spp. from food and environmental
More informationTest Method for Efficacy of Copper Alloy Surfaces as a Sanitizer
Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer Test Organisms: Staphylococcus aureus (ATCC 6538) Enterobacter aerogenes (ATCC 13048) Pseudomonas aeruginosa (ATCC 15442) Methicillin Resistant
More informationBacterial Counts - Quantitative Analysis of Microbes
Bacterial Counts - Quantitative Analysis of Microbes Introduction: It is often important to know not only what types of bacteria are in a sample but also how many of them are present. Food manufacturers
More informationProtocol Reference: Verification Protocol
Protocol Reference: Verification Protocol Contents 1. About BioBall Multishot 550 3 2. About This Protocol 4 3. Safety Precautions 4 4. Protocol Pre-approval 4 5. Protocol Scope 5 5.1. Intended Location
More informationTest Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces
Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces Test Organisms: Staphylococcus aureus (ATCC 6538) Enterobacter aerogenes (ATCC 13048) Pseudomonas aeruginosa
More informationGuidance. Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography (PET) Drugs DRAFT GUIDANCE
Guidance Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography (PET) Drugs DRAFT GUIDANCE This guidance document is being distributed for comment purposes only. Comments and
More informationNew York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765
New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765 Division of Environmental Health Sciences Albany, New York NYS DOH LEB-605 Aerobic
More informationINSTRUCTIONS FOR USE
INSTRUCTIONS FOR USE EZ-Accu Shot Microorganisms EZ-Accu Shot Select Microorganisms INTENDED USE EZ-Accu Shot and EZ-Accu Shot Select microorganisms are lyophilized, enumerated microorganism preparations
More informationPRESERVATIVE EFFICACY TEST FOR COSMETIC PRODUCT
1 SCOPE AND FIELD OF APPLICATION To determine the efficacy of the antimicrobial activity of preservatives used in cosmetic products. The method covers the determination of the suitability of preservation
More informationMicrobial Survival. Created on 2/25/ :05 AM
Microbial Survival Introduction The main objectives of this practical are: Verify, or otherwise, the Department of Health recommendation that food be cooked to 70 o C for 2 minutes or an equivalent time-temperature
More informationColiforms, Total and E. coli
Coliforms, Total and E. coli DOC316.53.01213 m-coliblue24 Broth PourRite Ampules 1 Method 10029 Scope and application: For potable water, nonpotable water, recreation water and wastewater. 1 USEPA accepted.
More informationActero Salmonella Enrichment Media Product Information
Actero Salmonella Enrichment Media Product Information INTENDED USE: Actero Salmonella Enrichment Media is a selective medium optimized for an improved enrichment of Salmonella spp. from food and environmental
More informationLAB NOTES FOR EXAM 1 SECTION
LAB NOTES FOR EXAM 1 SECTION EX. 2-1: DIVERSITY AND UBIQUITY OF MICROOGANISMS Purpose: Microorganisms are found everywhere in the environment around us. To demonstrate this and to get a taste of the different
More informationá62ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: TESTS FOR SPECIFIED MICROORGANISMS
USP 40 Microbiological Tests / á62ñ Microbiological Examination 1 á62ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: TESTS FOR SPECIFIED MICROORGANISMS INTRODUCTION The tests described hereafter
More informationTSA + LTHT CSG Contact Plate
TSA + LTHT CSG Contact Plate Article N : 100.0100 CSG Click & Safe gamma Use in Pharmaceutical Industry in clean rooms and isolators Use for detection of aerobic and anaerobic micro-organisms contact sampling,
More informationMicrobiological Methods
Microbiological Methods Making Media Pouring Culture Plates Sterile Technique Inoculating Plates and Culture Tubes Use of a Plate Counter to Estimate Microbial Population Densities Culturing Microorganisms
More informationBIO & PHARMA ANALYTICAL TECHNIQUES
BIO & PHARMA ANALYTICAL TECHNIQUES Chapter 11 by Dr. Siti Umairah Mokhtar Faculty of Engineering Technology umairah@ump.edu.my Chapter Description Aims Discuss theory, principles and application of analytical
More informationValidation Guide for and
Validation Guide for Microsart @filter and Microsart @media Table of Contents 1. Introduction 4 2 Quality and Its Assurance 5 2.1 Quality Assurance 5 2.2 Complete Traceability 5 2.3 DIN EN ISO Certificates
More informationUSEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.
, MF, m-tec, 8367 DOC316.53.001210 USEPA Membrane Filtration Method Method 8367 1 m-tec Scope and Application: For potable water, nonpotable water, recreation water and wastewater. 1 USEPA accepted. Test
More informationIsolation & Characterization of Bacteria
PR025 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Isolation & Characterization of Bacteria Teacher s Handbook (Cat. # BE 204) think proteins!
More informationPOPULATION ASSAY KIT INSTRUCTIONS FOR USE 10 EVERGREEN DRIVE, SUITE E BOZEMAN, MT 59715
POPULATION ASSAY KIT INSTRUCTIONS FOR USE 10 EVERGREEN DRIVE, SUITE E BOZEMAN, MT 59715 INSTRUCTIONS FOR USE The following procedures have been provided with this kit and should be followed exactly when
More informationEPK- EasyTest Patch Test Kit Manual
EPK- EasyTest Patch Test Kit Manual L-2730 The Patch Test Kit from Schroeder provides the necessary tools to determine levels of both water and solid particulate contamination present in a particular fluid
More information2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum
Microbiological Methods IX-B- 1 PRESUMPTIVE MEMBRANE FILTER METHOD AND CONFIRMATION OF PSEUDOMONAS AERUGINOSA PRINCIPLE SCOPE Presumptive Pseudomonas bacteria are quantitated by a membrane filter technique,
More informationFDA s Guidance for Industry
Sterile Drug Products Produced by Aseptic Processing - CGMPs Midwest FDC Conference November 4 2005 Susan Bruederle, Investigator FDA / ORA / Central Region Chicago District / Hinsdale IL FDA s Guidance
More informationBacterial Transformation: Unlocking the Mysteries of Genetic Material
PR009 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Bacterial Transformation: Unlocking the Mysteries of Genetic Material Teacher s Guidebook
More informationON-SITE ANALYSIS PIPELINE FLUIDS BACTERIA KIT
C P orrosion roducts D ivision Corrosion Products Division - MSES consultants, inc. ON-SITE ANALYSIS PIPELINE FLUIDS BACTERIA KIT Fluids-Microbiology Survey ON-SITE ANALYSIS KIT CONTENTS 2-30 ml Sample
More informationPHARMACY IV ADMIXTURE. Pharmacy 483 January 17, 2006 Kim Donnelly Affiliate Associate Professor
PHARMACY IV ADMIXTURE Pharmacy 483 January 17, 2006 Kim Donnelly Affiliate Associate Professor Pharmacist is responsible for ensuring that compounded sterile preparations are properly prepared, labeled,
More informationSterilAmp II Geobacillus stearothermophilus
SterilAmp II Geobacillus stearothermophilus TECHNICAL REPORT Complies to USP, ISO 11138, and all appropriate subsections Technical Data and Use of SterilAmp II Part #7709 Rev.5 25FEB14 Page 1 of 6 INTRODUCTION
More informationINTRODUCTION water-soluble Figure 1.
INTRODUCTION Natural waters contain bacteria. The aerobic gram negative bacillus of the genera Psedomonas, Alcalignes, and Flavobacterium are common in natural waters. Many of these bacteria are able to
More informationBuilt for Better Testing. EZ-Fit Filtration Units: Convenience without compromise. Data Sheet
Data Sheet Built for Better Testing EZ-Fit Filtration Units: Convenience without compromise The life science business of Merck KGaA, Darmstadt, Germany operates as MilliporeSigma in the U.S. and Canada.
More informationINSTRUCTIONS FOR USE. EZ-CFU Microorganisms INTENDED USE FORMULA COMPONENTS
INSTRUCTIONS FOR USE EZ-CFU Microorganisms INTENDED USE EZ-CFU microorganisms are lyophilized, enumerated microorganism preparations to be used in industrial laboratories for quality control purposes.
More informationDecontamination Effectiveness of Esco Celsafe CO2 Incubator Sterilization Feature using High Heat Temperature By Bekti Tri Sumaryati
Decontamination Effectiveness of Esco Celsafe CO2 Incubator Sterilization Feature using High Heat Temperature By Bekti Tri Sumaryati 1. Summary Esco Celsafe CO 2 Incubator sterilization feature, which
More information1. Low profile units 2 Normal profile sterilisation filter units 3. Each pack includes 12 glass-fibre prefilters
673-289 673-104 Nalgene, MF75 Series of Filter Units and Bottle Top Filters The MF75 series of filter units (except 115ml) are designed with an easy to use shape, with tapered sides and grip dimples for
More informationPuritan Environmental Sampling Kit (ESK )
Puritan Environmental Sampling Kit (ESK ) Table of Contents: Introduction Pg.2 Description..Pg.2 Production Information.... Pg.2-4 Attributes and Intended Uses... Pg.4-5 Common Food and Water Borne Pathogens...Pg.5-6
More informationClinical Swabs. Starswabs II bacteriology collection and transport systems
Clinical Swabs c o l l e c t i o n & t r a n s p o r t s y s t e m s Multitrans complete collection and transportation system for viruses, chlamydia, mycoplasma and ureaplasma Starswabs II bacteriology
More information168 West Main Street, #922, New Market, Md Revision 5.2 6/6/2017
QUICK START GUIDE 168 West Main Street, #922, New Market, Md. 21774 TABLE OF CONTENTS Introduction... 2 General Culture Guidelines... 3 Reservoir Bottle and Cap Assembly Sterilization... 4 Pre-culture...
More informationPURE CULTURE TECHNIQUES
PURE CULTURE TECHNIQUES Most specimens (from animal tissue, plant tissue, or environmental samples) will be mixed, with a variety of bacteria (or other microorganisms). A single gram of feces, for example,
More informationSTUDENT PAGE. Using Sterile Technique to Inoculate Bacterial Plates
Using Sterile Technique to Inoculate Bacterial Plates A sterile, or aseptic, technique is used to prevent microbial organisms from contaminating any surface other than the specific location where they
More informationNew York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765
New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765 Division of Environmental Health Sciences Albany, New York NYS DOH LEB-603 Preparation
More informationEZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration
EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Ready-to-use sterilized filtration devices for
More informationIntroduction. Michael J. Miller, Ph.D. RMM»
RMM» Case Study of a New Growth-based Rapid Microbiological Method (RMM) that Detects the Presence of Specific Organisms and Provides an Estimation of Viable Cell Count Michael J. Miller, Ph.D. President
More informationBIOSCAN* ATP method for monitoring of biofilm/sessile microorganisms in cooling systems
Water Technologies & Solutions microbiological procedure MB013 BIOSCAN* ATP method for monitoring of biofilm/sessile microorganisms in cooling systems summary of method This method can be used to determine