Bringing the EuroFlow Concept
|
|
- Job Heath
- 6 years ago
- Views:
Transcription
1 Bringing the EuroFlow Concept
2 Cytognos - EuroFlow Supporting Company Company Overview Cytognos provides through worldwide distribution a broad range of reagents and software for flow cytometry applications in clinical laboratories. Cytognos, EuroFlow supporting company, plays the role of providing solutions for flow cytometry. That purpose led to the release of the EuroFlow product line: Screening Tubes, Infinicyt Software and Specialized Technical Support. Product Line Screening Tubes 8-color immunostaining for fast and easy flow cytometric analysis. Cytognos screening tubes (LST-11, ALOT-7 and SST) include markers that have been selected to allow accurate identification of cell populations with a single tube. Infinicyt Software Easy handling of large datasets and integration of 8-color staining into a single multicolor file. Infinicyt facilitates interpretation and automated pattern recognition of normal, reactive, and aberrant leucocyte populations. Specialized Technical Support Cytognos technical specialists are available to provide fieldor -based assistance and support. Cytognos specialists are highly qualified personnel who can help on: Calibration and compensation protocols. Preparation and staining protocols. Infinicyt analysis. EuroFlow Consortium EuroFlow is a scientific consortium composed of research groups and companies aiming for the development and standardization of fast, accurate, and highly sensitive flow cytometry tests for diagnosis and prognostic classification of hematological malignancies as well as for evaluation of treatment effectiveness during follow-up (1). EuroFlow antibody panels are unique due to its multicenter validation process performed by several laboratories in successive evaluation rounds and large number of patients (1,2). EuroFlow 8-color antibody panels and EuroFlow standard operating procedures (SOPs) have been designed to be used in combination with Infinicyt software for multivariate data analysis (1-6). The publications are available at Contact us at support@cytognos.com and ask for specialized technical support
3 EuroFlow Screening Tubes EuroFlow screening tubes are intended for a rapid differential identification of all relevant cell subsets. Subsequent to initial sample screening, specific antibody panels are applied for further characterization and classification of the suspected cells. Novel fluorochromes Cytognos offers two new fluorochromes, OC515 and APC-C750, that have been conjugated with different antibodies to complement the EuroFlow panels. OC515 is compatible to Pacific Orange and APC-C750 to APC-H7. These new fluorochromes reach EuroFlow high standards in relation to stability, brightness, limited spectral overlap and compensation requirements. Validated antibodies Cytognos offers a list of antibodies which can be used as a starting point for all EuroFlow antibody panels. Ask for a sample at admin@cytognos.com
4 Screening Kits LST-11 KIT Lymphoid Screening Tube The LST-11 kit is designed for detecting aberrant mature lymphocyte populations (B, T and NK lineage). It is used to evaluate several clinical manifestations such as peripheral blood lymphocytosis, bone marrow lymphoid infiltrates, enlargement of one or multiple other tissues (e.g. lymphadenopathy, splenomegaly or other organomegalies) or emergence of a serum monoclonal component. PacB OC515 FITC PE PerCP-Cyanine5.5 PE-Cyanine7 APC APC-C750 CD20 CD4 CD45 CD8 SmIgλ CD56 SmIgκ CD5 CD19 SmCD3 CD38 Pathological peripheral blood sample stained with LST-11 kit. Clonal Ig κ B-cell population (purple), remaining normal B-cell population (blue) and T-cell population (green); remaining events are shown in grey in CD45:OC515 vs. SSC dot plot. Normal B cells Clonal B cells T cells Outstanding Features (LST and SST) Ready-to-use EuroFlow combination Lyophilized format Selected fluorochromes Time saving Data accuracy Reliable results High stability Fewer storage requirements Exceptional brightness Minimum spectral overlap Give an extra value to your laboratory work flow with our EuroFlow product line Contact us at support@cytognos.com and ask for specialized technical support
5 SST KIT Small Sample Screening Tube The SST kit is an enhanced version of the EuroFlow LST. It is optimized for the analysis of low cellularity samples such as cerebrospinal fluid, vitreous humour, fine needle aspirates, etc. PacB OC515 FITC PE PerCP-Cyanine5.5 PE-Cyanine7 APC APC-C750 CD20 CD45 CD8 SmIgλ CD56 SmIgκ CD4 CD19 SmCD3 CD14 CD38 Pathological cerebrospinal fluid stained with SST kit. Clonal Ig κ B-cell population (purple) and T-cell population (green). Clonal B cells T cells Marker CD3 CD4 CD5 CD8 CD14 CD19 CD20 CD38 CD45 CD56 SmIgκ SmIgλ Reactivity Mature T cells T helper cells, monocytes, macrophages and dendritic cells Mature T cells, subpopulation of B cells T cytotoxic cells, subpopulation of NK cells Monocytes B cells (precursors to plasma cells) Mature B cells (except plasma cells) Plasma cells, activated T cells, B cell precursors Leucocytes NK cells, subpopulation of T cells Kappa light chain (B cells) Lambda light chain (B cells) Ask for a sample at admin@cytognos.com
6 Screening Kits ALOT-7 KIT Acute Leukemia Orientation Tube The ALOT-7 kit is designed for initial assessment of the nature of immature populations of hematopoietic cells in samples with suspicion of acute leukemia (B- or T-lymphoid vs. non-lymphoid lineage or mixed phenotype). PacB OC515 FITC PE PerCP-Cy5.5 PE-Cyanine7 APC APC-C750 CyCD3 CD45 CyMPO CyCD79a - CD19 CD7 SmCD3 Pathological bone marrow sample stained with ALOT-7 kit. B lineage blast cells (purple), remaining normal B-cell population (blue), normal T-cell population (yellow) and neutrophils (green). Normal B cells Blast cells T cells Neutrophils Euroflow Panels The ALOT-7 kit, in combination with CD34- PerCP-Cy5.5, can orientate with exactitude further analysis of acute leukemia samples. Together with BCP-ALL, B-CLPD, and AML/MDS panels, the complete detection or exclusion of virtually all types of hematological diseases can be achieved. Infinicyt Compass tool helps to orientate later analysis by comparison of pathological samples with the ALOT screening tube database. Outstanding Features Cytoplasmic antibodies in a single vial EuroFlow combination Selected fluorochromes Marker CyMPO CD3 CD7 CyCD79a CD19 CD45 Reactivity Time saving Data accuracy Reliable results Exceptional brightness Minimum spectral overlap Myeloid lineage Immature T cells (Cy) and mature T cells (Sm) Mature T cells, NK cells, hematopoietic cells B cell precursors B cells (precursors to plasma cells) Leucocytes Contact us at support@cytognos.com and ask for specialized technical support
7 Validated antibodies Validated Antibodies Cytognos has included remarkable antibodies within EuroFlow reference antibody list. Consult to obtain the last updated list. Markers CD8-FITC CD38-Pure CD38-FITC CD45-OC515 CD56-PE cycd79a-pe SmIgΚ-PE SmIgλ-FITC cytcrβ-apc Application in EuroFlow LST, SST and B-CLPD PCD PCD ALOT, LST, SST, AML, B-CLPD, BCP-ALL, NK-CLPD, T-ALL and T-CLPD LST, SST, PCD, AML and B-CLPD ALOT LST, SST, PCD, B-CLPD and BCP-ALL LST, SST, PCD, B-CLPD and BCP-ALL T-ALL Reference antibodies Alternative antibodies Technical support Cytognos technical specialists are highly qualified personnel who have been trained to provide specialized support for EuroFlow product line to our customers. Our specialists are available to provide field- or -based assistance on: EuroFlow Standard Operating Protocol for instrument setup and compensation. EuroFlow Standard Operating Procedures for sample preparation and staining. Analysis of flow cytometric data with Infinicyt software. Ask for a sample at admin@cytognos.com
8 Literature 1 Van Dongen JJM, Orfao A. EuroFlow: Resetting leukemia and lymphoma immunophenotyping. Basis for Companion Diagnostics in personalized medicine. LEUKEMIA 2012, in press. 2 Van Dongen JJM, Lhermitte L, Böttcher S, Almeida J, van der Velden VHJ, Flores-Montero J, Rawstron A, Asnafi V, Lécrevisse Q, Lucio P, Mejstrikova E, Szczepanski T, Kalina T, de Tute R, Brüggemann M, Sedek L, Cullen M, Langerak AW, Mendonça A, Macintyre E, Martin-Ayuso M, Hrusak O, Vidriales MB, Orfao A. EuroFlow antibody panels for standardized n-dimensional flow cytometric immunophenotyping of normal, reactive and malignant leukocytes. LEUKEMIA 2012, in press. 3 Kalina T, Flores-Montero J, van der Velden VHJ, Martin-Ayuso M, Böttcher S, Ritgen M, Almeida J, Lhermitte L, Asnafi V, Mendonça A, de Tute R, Cullen M, Sedek L, Vidriales MB, Pérez JJ, te Marvelde JG, Mejstrikova E, Hrusak O, Szczepanski T, van Dongen JJM, Orfao A. EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols. LEUKEMIA 2012, in press. 4 Pedreira CE, Costa ES, Barrena S, Lecrevisse Q, Almeida J, van Dongen JJM, Orfao A. Generation of flow cytometry data files with a potentially infinite number of dimensions. CYTOMETRY, PART A, 2008, 73A: Pedreira CE, Costa ES, Almeida J, Fernández C, Quijano S, Flores J, Barrena S, Lecrevisse Q, van Dongen JJM, Orfao A. A probabilistic approach for the evaluation of minimal residual disease by multiparameter flow cytometry in leukemic B-cell chronic lymphoproliferative disorders. CYTOMETRY, PART A, 2008, 73A: Costa ES, Peres RT, Almeida J, Lécrevisse Q, Arroyo ME, Teodósio C, Pedreira CE, van Dongen JJ, Orfao A. Harmonization of light scatter and fluorescence flow cytometry profiles obtained after staining peripheral blood leucocytes for cell surface-only versus intracellular antigens with the Fix & Perm reagents. CYTOMETRY, PART B, 2010, 78B: More publications related to EuroFlow consortium and EuroFlow product line can be found at: and Spain Pol. La Serna, Nave Santa Marta de Tormes Salamanca Contact information The Netherlands Erasmus MC (Faculteitsgebouw) Department of Immunology Room Ee 818 Dr. Molewaterplein GE Rotterdam Consult which Cytognos distributor is in your area at cytognos Flow Cytometry Solutions Design and development of reagents, software and techniques that provide innovative solutions in the flow cytometry field. admin@cytognos.com support@cytognos.com Follow us
AVANÇOS NO DIAGNÓSTICO E CLASSIFICAÇÃO IMUNOFENOTIPICA DE LEUCEMIAS LINFOCITICAS CRÓNICAS B
AVANÇOS NO DIAGNÓSTICO E CLASSIFICAÇÃO IMUNOFENOTIPICA DE LEUCEMIAS LINFOCITICAS CRÓNICAS B CANCER RESEARCH CENTER IBSAL-UNIVERSITY OF SALAMANCA/CSIC HEMO 2016 Congreso Brasileiro de Hematologia, Hemoterapia
More informationFor Reference Use Only
Exclusively Distributed in the US by: 26-G Keeywadin Drive, Salem NH, 03079 800-592-5726 www.alpco.com Small Sample Tube (CD20 -Pacific Blue TM / CD45-0C515 / CD8 + smig -FITC / CD56 + smig PE / CD4 PerCP-Cyanine5.5
More informationCalibración de equipos de citometría para empleo de paneles EuroFlow
Calibración de equipos de citometría para empleo de paneles EuroFlow Departamento de Medicina, Centro de Investigación del Cáncer y Servicio de Citometría. Universidad de Salamanca, Salamanca, España.
More informationRef: CYT-MM-MRD. For Research Use Only. Not for use in diagnostic procedures
Ref: CYT-MM-MRD For Research Use Only. Not for use in diagnostic procedures MM MRD VIALS AND COMPENSATION TUBES ARE LYOPHILIZED PRODUCTS. READ CAREFULLY THE FOLLOWING INSTRUCTIONS FOR RECONSTITUTION: The
More informationUK NEQAS for Leukocyte Typing Scientific Meeting, Sheffield, UK 24 June 2013
UK NEQAS for Leukocyte Typing Scientific Meeting, Sheffield, UK 24 June 2013 Flow cytometry vs. Molecular techniques for Diagnosis, Classification and Monitoring of Hematological Malignancies Need of innovation,
More informationQuality Control in polychromatic Flow Cytometry - EuroFlow interlaboratory standardization
IV. International Symposium Flow Cytometry/Molecular Biology HOSPITAL ISRAELITA ALBERT EINSTEIN São Paulo 2012 Quality Control in polychromatic Flow Cytometry - EuroFlow interlaboratory standardization
More informationEuroFlow: Resetting leukemia and lymphoma immunophenotyping. Basis for companion diagnostics and personalized medicine
Leukemia (2012) 26, 1899 1907 & 2012 Macmillan Publishers Limited All rights reserved 0887-6924/12 www.nature.com/leu EDITORIAL EuroFlow: Resetting leukemia and lymphoma immunophenotyping. Basis for companion
More informationValidation of reagents and mixes in haematology. Tine Venken
Validation of reagents and mixes in haematology Tine Venken Molecular Biology and Cytometry Course 23-24/03/2017 Overview ISO 15189:2012 Validation of reagents Validation of mixes Daily practice Conclusions
More informationRef: CYT-MM-MRD. For research use only
Distributed By: ALPCO 26-G Keewaydin Drive Salem, NH 03079 www.alpco.com P 800-592-5726 F 603-898-6854 Ref: CYT-MM-MRD For research use only MM-MRD VIALS ARE A LYOPHILIZED PRODUCT. READ CAREFULLY THE FOLLOWING
More informationEuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols
Leukemia (2012) 26, 1986 2010 & 2012 Macmillan Publishers Limited All rights reserved 0887-6924/12 www.nature.com/leu SPECIAL REPORT EuroFlow standardization of flow cytometer instrument settings and immunophenotyping
More informationFlow Cytometry in the Diagnosis of Hematopoietic Neoplasia. Brent Wood MD, PhD Professor, Laboratory Medicine University of Washington, Seattle
Flow Cytometry in the Diagnosis of Hematopoietic Neoplasia Brent Wood MD, PhD Professor, Laboratory Medicine University of Washington, Seattle 1 Flow Cytometer 2 The Power of Flow Cytometry Single cell
More informationCLEARLLAB LS LYMPHOID SCREEN REAGENT
CLEARLLAB LS LYMPHOID SCREEN REAGENT CE MARKED ANTIBODY COMBINATION FOR LEUKEMIA / LYMPHOMA ANALYSIS Because Your Patient is Her Everything BECAUSE YOUR PATIENT IS HER EVERYTHING ClearLLab LS Lymphoid
More informationTen-Color 15 Antibody Flow Cytometry Panel for Immunophenotyping of Lymphocyte Population
Ten-Color 15 Antibody Flow Cytometry Panel for Immunophenotyping of Lymphocyte Population Amr Rajab BSc, MLT, QCYM (ASCP) Flow cytometry Technical Specialist LifeLabs 100 International Blvd. Toronto, ON
More informationdetection limit of cytomorphological techniques detection limit of immunophenotyping and PCR techniques cure follow-up in years
relative frequency of leukemic cells 1 10-1 10-2 10-3 10-4 10-5 10-6 10-7 0 Detection of minimal residual disease (MRD) detection limit of cytomorphological techniques detection limit of immunophenotyping
More informationCellular phenotyping and application of cytometry for diagnostics purposes Part I. dr n. med. Karolina Bukowska-Straková
Cellular phenotyping and application of cytometry for diagnostics purposes Part I dr n. med. Karolina Bukowska-Straková Flow cytometry - wikipedia definition ;-) Flow cytometry (abbreviated: FCM) is a
More informationLambda-APC-C750 Ref: CYT-LAC750
Lambda-APC-C750 Ref: CYT-LAC750 For In Vitro Diagnostic use INTENDED USE Lambda-APC-C750 is a polyclonal antibody (pab) labelled with the tandem allophycocyanine-c750 (APC- C750) and designed for use as
More informationImmunophenotyping of Peripheral Blood and Bone Marrow Cells by Flow Cytometry *Akanni EO and # Palini A.
Immunophenotyping of Peripheral Blood and Bone Marrow Cells by Flow Cytometry *Akanni EO and # Palini A. * Department of Haematology & Blood Transfusion,College of Health Science, Ladoke Akintola University
More informationStandardized flow cytometry for highly sensitive MRD measurements in B-cell acute lymphoblastic leukemia
Supplemental Methods & Figures Standardized flow cytometry for highly sensitive MRD measurements in B-cell acute lymphoblastic leukemia Prisca Theunissen 1#, Ester Mejstrikova 2#, Lukasz Sedek 3, Alita
More informationPRINCIPLES OF THE PROCEDURE
CD19 For In Vitro Diagnostic use Fluorochrome Reference Clon Isotype Format µl/test FITC CYT-19F6 HIB19 IgG1 1 ml/200 test 5 PerCP-Cyanine5.5 CYT-19C8 HIB19 IgG1 150ul/50 test 3 PE-Cyanine5 CYT-19C3 HIB19
More informationcatalog 2011 Reagents and Software for Flow Cytometry
catalog 2011 Reagents and Software for Flow Cytometry catalog 2011 Introduction... 4 Antibodies (Ab) against Human Antigens New Fluorochrome-Conjugated Antibodies... 6 Index Single color antibodies against
More informationBIMM18 Dec 20 th - Flow cytometry in clinical diagnostics
BIMM18 Dec 20 th - Flow cytometry in clinical diagnostics I. B cell leukemia and lymphomas Immunophenotyping as part of the diagnostic work- up of hematologic malignancies offers a rapid and effective
More informationA TÉCNICA DO NGF (Next Generation Flow) PARA ESTUDO DE DRM
A TÉCNICA DO NGF (Next Generation Flow) PARA ESTUDO DE DRM CANCER RESEARCH CENTER IBSAL-UNIVERSITY OF SALAMANCA/CSIC HEMO 2016 Congreso Brasileiro de Hematologia, Hemoterapia y Terapia Celular Florianopolis,
More informationSingle Tube, Six-Color Flow Cytometric Analysis Is a Sensitive and Cost-Effective Technique for Assaying Clonal Plasma Cells
Hematopathology / Flow Cytometric Analysis of Clonal Plasma Cells Single Tube, Six-Color Flow Cytometric Analysis Is a Sensitive and Cost-Effective Technique for Assaying Clonal Plasma Cells Derek K. Marsee,
More informationNovel Lymphocyte Screening Tube Using Dried Monoclonal Antibody Reagents
Cytometry Part B (Clinical Cytometry) 88B:361 370 (2015) Original Article Novel Lymphocyte Screening Tube Using Dried Monoclonal Antibody Reagents Benjamin D. Hedley, 1 * Michael Keeney, 1 Janice Popma,
More informationPrinciples of Multicolor Panel Design BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company.
1 Principles of Multicolor Panel Design 2 Common Multicolor Applications Intracellular cytokine staining Regulatory T cells (Tregs) Protein phosphorylation (BD Phosflow) Leukemia and lymphoma phenotyping
More informationCongreso Nacional del Laboratorio Clínico 2016
Técnicas de alta sensibilidad en la detección de enfermedad mínima residual en Mieloma Múltiple J. Flores-Montero, MD, PhD Departamento de Medicina, Servicio Central de Citometría, Centro de Investigación
More informationProposals of B cells standard immunophenotyping in mature B cell non-hodgkin lymphomas
Clinical immunology Proposals of B cells standard immunophenotyping in mature B cell non-hodgkin lymphomas URSZULA PODSTAWKA, IZABELLA SZCZEPAŃSKA, JOANNA KOPEĆ-SZLĘZAK Department of Hematological Cytobiology,
More informationAmendment to ALL IC-BFM 2009 Standard Operating Procedure. 6-color FLOW-MRD detection in ALL
Amendment to ALL IC-BFM 2009 Standard Operating Procedure 6-color FLOW-MRD detection in ALL Version June 2014 M.N. Dworzak/J. Kappelmayer ALL IC-BFM 2009 FLOW-MRD SOP amendment June 2014 page 1 Marker
More informationA high recovery and high purity data analysis strategy for rare abnormal plasma cell events using the DuraClone RE PC Tube
APPLICATION NOTE A high recovery and high purity data analysis strategy for rare abnormal plasma cell events using the DuraClone RE PC Tube Dr Agnieszka Blum Charité Virchow Hospital, Stem Cell Facility,
More informationWhat you need to know before designing a panel
Design What you need to know before designing a panel For Research Use Only. Not for use in diagnostic or therapeutic procedures. Alexa Fluor is a registered trademark of Life Technologies Corporation.
More informationYour Clinical Flow Cytometry Provider
Caltag Medsystems Ltd. Your Clinical Flow Cytometry Provider s Automated Sample Preparation Data Integration and Analysis Software Immunophenotyping EuroFlow Screening Tubes Single and Multi-Colour Antibodies
More informationIncorporating New, Bright Fluorochromes into Multicolor Panel Design
Incorporating New, Bright Fluorochromes into Multicolor Panel Design Maria C. Jaimes, MD Senior Staff Scientist BD Biosciences 23-14684-00 Overview Multicolor flow: successful application prerequisites
More informationFlow cytometry has become an increasingly important
9-Color and 10-Color Flow Cytometry in the Clinical Laboratory Brent Wood, MD, PhD Context. The development of commercial flow cytometers capable of detecting more than 10 simultaneous fluorescent signals
More informationPERFECT-COUNT MICROSPHERES
PERFECT-COUNT MICROSPHERES Perfect-Count Microspheres-Product code PCB-100 for 100 tests Introduction In recent years, the determination of absolute cell counts has been shown to be relevant in different
More informationDesigning and Implementing a High-Level Multicolor Flow Cytometry Assay. Brent Wood MD PhD Department of Laboratory Medicine University of Washington
Designing and Implementing a High-Level Multicolor Flow Cytometry Assay Brent Wood MD PhD Department of Laboratory Medicine University of Washington Define Purpose of Assay Most important question What
More informationPrinciples of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288
Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting Shoreline Community College BIOL 288 Flow Cytometry What is Flow Cytometry? Measurement of cells or particles
More informationBoundary-breaking acoustic focusing cytometry
Boundary-breaking acoustic focusing cytometry Introducing the Attune NxT Acoustic Focusing Cytometer a high-performance system that s flexible enough for any lab One of the main projects in my laboratory
More informationStrategies for Assessment of Immunotoxicology in Preclinical Drug Development
Strategies for Assessment of Immunotoxicology in Preclinical Drug Development Rebecca Brunette, PhD Scientist, Analytical Biology SNBL USA Preclinical Immunotoxicology The study of evaluating adverse effects
More informationFlow Cytometry - The Essentials
Flow Cytometry - The Essentials Pocket Guide to Flow Cytometry: 1. Know your Cytometer 2. Understanding Fluorescence and Fluorophores 3. Gating Process 4. Controls 5. Optimization 6. Panel Building 7.
More informationApplication Note. Assay Portability on the BD FACSVerse System. Summary. Maria Jaimes, Yibing Wang, Catherine McIntyre, and Dev Mittar
September Assay Portability on the BD FACSVerse System Maria Jaimes, Yibing Wang, Catherine McIntyre, and Dev Mittar Contents Summary Introduction 3 Objective 4 Methods 6 Results Discussion Conclusions
More informationMRD detection in multiple myeloma: comparison between MSKCC 10-color single-tube and EuroFlow 8-color 2-tube methods
REGULAR ARTICLE MRD detection in multiple myeloma: comparison between MSKCC 1-color single-tube and EuroFlow 8-color 2-tube methods Mikhail Roshal, 1 Juan A. Flores-Montero, 2-4 Qi Gao, 1 Maesa Koeber,
More informationPrinciples of Immunophenotyping
Principles of Immunophenotyping % of Cell types? Immune activation? Changes based on health state? Moving from a heterogeneous population of blood cells to identifying the presence and proportion of different
More informationStandardization of Minimal Residual Disease Testing in Multiple Myeloma
Standardization of Minimal Residual Disease Testing in Multiple Myeloma Linda B. Baughn 1 and Michael A. Linden 2 * Multiple myeloma (MM) 3 is an incurable neoplasm of the bone marrow characterized by
More informationResolving Stem Cell Heterogeneity Using Flow Cytometry
Resolving Stem Cell Heterogeneity Using Flow Cytometry Mirko Corselli, PhD Senior Scientist We have not fully utilized the power of flow cytometry to address biological questions in other systems Flow
More informationHigh-dimensional flow-cytometric analysis of human B-cell populations
High-dimensional flow-cytometric analysis of human B-cell populations The BD FACSCelesta cell analyzer and FlowJo software together enable deep analysis of B-cell biology Features High-resolution analysis
More informationKey terms: flow cytometry; reagents; reporting; consensus; optimal
Cytometry Part B (Clinical Cytometry) 72B:S14 S22 (2007) 2006 Bethesda International Consensus Recommendations on the Immunophenotypic Analysis of Hematolymphoid Neoplasia by Flow Cytometry: Optimal Reagents
More informationBest practices in panel design to optimize the isolation of cells of interest
Sort Best practices in panel design to optimize the isolation of cells of interest For Research Use Only. Not for use in diagnostic or therapeutic procedures. Alexa Fluor is a registered trademark of Life
More information11/19/2013. Janine Zankl FACS Core Facility 13. November Cellular Parameters. Cellular Parameters. Monocytes. Granulocytes.
DEPARTEMENT BIOZENTRUM Janine Zankl FACS Core Facility 13. November 2013 Cellular Parameters Granulocytes Monocytes Basophils Neutrophils Lymphocytes Eosinophils Cellular Parameters 1 What Is Flow Cytometry?
More informationBD OneFlow PCST. 10 tests per kit Catalog No
BD OneFlow PCST 10 tests per kit Catalog No. 659912 IVD BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. 2016 BD 2/2016 23-16816-00 Becton, Dickinson and Company BD Biosciences
More informationHematopoietic Progenitor Cell Product Characterization
Hematopoietic Progenitor Cell Product Characterization Carolyn A. Taylor, Ph.D. Professor of Medicine Director of BMT Program Cell Processing Laboratory Product Testing and Characterization Goals Required
More informationNavios EX FLOW CYTOMETER POWERFUL, DEPENDABLE CLINICAL FLOW CYTOMETRY
Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE CLINICAL FLOW CYTOMETRY BECAUSE EVERY EVENT MATTERS The Navios EX flow cytometer offers a solution for advanced cytometry applications optimized for the clinical
More informationNovel Developments in Cytometry. Martin Adelmann Marketing Manager Cellular Analysis & Life Science Beckman Coulter EMEAI
Novel Developments in Cytometry Martin Adelmann Marketing Manager Cellular Analysis & Life Science Beckman Coulter EMEAI 1 Innovation in Flow Cytometry Cellios EPICS 1V 2 lasers, 3 colors EPICS Profile
More informationIdentification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer. Application Note
Identification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer Application Note Sylvie Veriac Valérie Perrone Madeleine Avon Abstract Agilent Equipment: 2100 bioanalyzer
More informationA previous ICCS Module entitled Instrument optimization - Adjusting PMT voltages and compensation 1 should be read as a prerequisite to this module.
Sponsored and reviewed by ICCS Quality and Standards Committee Title: Compensation Tips for Beckman Coulter 10-Color Navios Platform Written by: Salima Janmohamed-Anastasakis Ph.D., Applications Scientist,
More informationAnatomy of a flow cytometer
Anatomy of a flow cytometer Fluidics Optics Electronics Cells in suspension flow in single-file through an illuminated volume where they scatter light and emit fluorescence that is collected, filtered,
More informationReview of techniques in flow cytometry. Peter Meeus Onze-Lieve-Vrouwziekenhuis, Aalst 5 may 2011, SCK/CEN Mol
Review of techniques in flow cytometry Peter Meeus Onze-Lieve-Vrouwziekenhuis, Aalst 5 may 2011, SCK/CEN Mol Cytometry definitions The counting and measuring of cells,... Mosby's Medical Dictionary, 8th
More informationBD Multicolor CompBeads
4/2015 23-9955-01 IVD BD Multicolor CompBeads 100 compensation setups Catalog No. 644204 BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. 2015 BD Becton, Dickinson and
More informationSelected Topics in Electrical Engineering: Flow Cytometry Data Analysis
Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis Bilge Karaçalı, PhD Department of Electrical and Electronics Engineering Izmir Institute of Technology Outline Experimental design
More informationINTRODUCTION TO FLOW CYTOMETRY
DEPARTEMENT BIOZENTRUM INTRODUCTION TO FLOW CYTOMETRY F ACS C ore F acility Janine Zankl FACS Core Facility 3. Dezember 2015, 4pm Cellular Parameters Granulocytes Monocytes Basophils Lymphocytes Neutrophils
More informationCancer inflammation research applications and products
Cancer inflammation research applications and products Flow cytometry Immunoassays Cell imaging Instrumentation Invitrogen Attune NxT Flow Cytometer Antibodies RNA flow Conjugated antibodies for flow cytometry
More informationBD OneFlow B-CLPD T1
BD OneFlow B-CLPD T1 20 tests per kit Catalog No. 659293 IVD 2016 BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company. 12/2016 23-17184-00 Becton, Dickinson and Company
More informationBeyond Colorful Science. A Practical Approach to Setting Up Multicolor Panels
Beyond Colorful Science A Practical Approach to Setting Up Multicolor Panels ISCT Paris April 2014 Layout: Multicolor Panel Design Identify the pitfalls Have a look at issues with spectral overlap How
More information18/08/2011. Principles of Flow Cytometry (Practised in a Clinical Laboratory) Cytometer Components. Noel Williams Immunobiology Division of Immunology
Optical Measurement Principles Principles of Flow Cytometry (Practised in a Clinical Laboratory) Noel Williams Immunobiology Division of Immunology Cytometer Components Reagents Cytometer Setup Cytometer
More informationInterest in any of the products, request or order them at Bio-Connect Diagnostics.
CE IVD Minicatalog Interest in any of the products, request or order them at Bio-Connect Diagnostics. Bio-Connect Diagnostics B.V. T NL +31 (0)26 326 44 60 T BE +32 (0)2 502 12 53 Begonialaan 3a F NL +31
More informationDesigning and Validating a Multicolor Flow Cytometry Assay. Brent Wood MD PhD Department of Laboratory Medicine University of Washington
Designing and Validating a Multicolor Flow Cytometry Assay Brent Wood MD PhD Department of Laboratory Medicine University of Washington Specimen Handling Sample Requirements 5 ml Peripheral blood (EDTA,
More informationMinimum Information about a Flow Cytometry Experiment (MIFlowCyt) Annotation
Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) Annotation 1. Experiment Overview 1.1 Purpose The purpose of these sets of experiments is to develop a methodology of identifying and quantifying
More informationHigh-throughput automation with the Attune NxT Autosampler: consistent results across all wells and across plates
APPLICATION NOTE Attune NxT Flow Cytometer with Autosampler High-throughput automation with the Attune NxT Autosampler: consistent results across all wells and across plates Introduction The emerging field
More informationIntroduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Assistant Product Manager BDBiosciences
Introduction to Flow Cytometry -- BD FACSCanto II TM Daisy Kuo Assistant Product Manager E-mail: daisy_kuo@bd.com BDBiosciences Outline Basic Concept of Flow Cytometry FACSCanto II System Introduction
More informationarc lamp is substituted. Before
CE update [cytology hematology generalist] The Principles of Flow Cytometry Antony C. Bakke, PhD From the Department of Pathology, Oregon Health Sciences University, Portland, OR On completion of this
More informationINTENDED PURPOSE. TECHNICAL SUMMARY.
Product: FITC Anti-Human CD2 Cat. Ref: 2F-100T Reagent provided: 100 test (20μl/test) Description: Mouse Monoclonal Anti-Human CD2 FITC is recommended for use in flow cytometry for identification of peripheral
More informationRuud Hulspas, Mike Keeney, Ben Hedley and Andrea Illingworth
Sponsored and reviewed by ICCS Quality and Standards Committee Title: Quality of Reagents Monoclonal Antibodies Written by: Date: March 6, 2018 Ruud Hulspas, Mike Keeney, Ben Hedley and Andrea Illingworth
More informationDURACLONE IM ACCELERATE YOUR PACE IN IMMUNE SYSTEM RESEARCH. For Reseach Use Only - Not for use in Diagnostic procedures
DURACLONE IM ACCELERATE YOUR PACE IN IMMUNE SYSTEM RESEARCH Your clinical research trial companion For Reseach Use Only - Not for use in Diagnostic procedures ACCELERATE YOUR PACE IN IMMUNE SYSTEM RESEARCH
More informationab pdc Subset Phenotyping Kit
ab177772 pdc Subset Phenotyping Kit Instructions for Use A set of antibodies designed to identify pdcs and subsets of pdcs by multi-color flow cytometry. This product is for research use only and is not
More informationCorporate Medical Policy
Corporate Medical Policy File Name: Origination: Last CAP Review: Next CAP Review: Last Review: flow_cytometry 1/1/2019 N/A 1/1/2020 1/1/2019 Policy Effective April 1, 2019 Description of Procedure or
More informationESTRATEGIAS ACTUALES DE ANALISIS DE DATOS POR CMF: EL PROGRAMA INFINICYT DIAGNOSTICS IN HEMATO-ONCOLOGY APPLICATIONS OF FLOW CYTOMETRY
ESTATEGIAS ATUALES DE ANALISIS DE DATOS PO MF: EL POGAMA INFINIYT ANE ESEAH ENTE, UNIVESITY & UNIVESITY HOSPITAL of SALAMANA (SPAIN) urso Avanzado de Actualización en Oncohematología por citometria de
More informationLABORATORY ASSESSMENT OF HAEMATOLOGY ONCOLOGY IMMUNOPHENOTYPING. First Edition Australasian Cytometry Society Laboratory Assessment Document
LABORATORY ASSESSMENT OF HAEMATOLOGY ONCOLOGY IMMUNOPHENOTYPING First Edition 2018 Australasian Cytometry Society Laboratory Assessment Document Paper-based publications This work is copyright. You may
More informationUnderstanding Flow Cytometry
Understanding Flow Cytometry The Basic Concepts Maree Bagnara Products Sales Specialist/Account Manager Flow Cytometry PN775136 1 Successful Flow Cytometry data is driven by.. Understanding the Biology
More informationFluorochrome: Fluorescein isothiocyanate (Molecular Probes) INTENDED PURPOSE.
Product: FITC Anti-Human CD14 Cat. Ref: 14F-100T Reagent provided: 100 test (20μl / test) Description: Monoclonal Mouse Anti-Human CD14 FITC is recommended for use in flow cytometry for identification
More informationFlexible, Intuitive and Affordable
Data Sheet guava easycyte Flow Cytometry Systems Flexible, Intuitive and Affordable The guava flow cytometry systems are easy to use and deliver complete and comprehensive cell analysis right on your benchtop.
More informationFLOW CYTOMETRY METHODS FOR IDENTIFYING MOUSE HEMATOPOIETIC STEM AND PROGENITOR CELLS
TECHNICAL BULLETIN FLOW CYTOMETRY METHODS FOR IDENTIFYING MOUSE HEMATOPOIETIC STEM AND PROGENITOR CELLS Background The phenotypic characterization of mouse hematopoietic stem and progenitor cells (HSPCs),
More informationa Beckman Coulter Life Sciences: White Paper
a Beckman Coulter Life Sciences: White Paper DuraClone improves standardization of compensation workflow for high content multicolor applications by flow cytometry Authors: Neha Girish 2, Sudharsan Sathyamurthy
More informationINTERNATIONAL SOCIETY OF LABORATORY HEMATOLOGY. 30TH INTERNATIONAL SYMPOSIUM May, 2017 / HONOLULU, HAWAII
INTERNATIONAL SOCIETY OF LABORATORY HEMATOLOGY 30TH INTERNATIONAL SYMPOSIUM 04-06 May, 2017 / HONOLULU, HAWAII Michael Keeney, ART, FCSMLS(D) Coordinator Special Hematology, London Health Sciences Centre,
More informationNature Immunology: doi: /ni Supplementary Figure 1
Supplementary Figure 1 Validation of the monoclonal antibody to mouse ACKR1 and expression of ACKR1 by BM hematopoietic cells. (a to d) Comparison of immunostaining of BM cells by anti-mouse ACKR1 antibodies:
More informationIntroduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Application Specialist BDBiosciences
Introduction to Flow Cytometry -- BD FACSCanto II TM Daisy Kuo Application Specialist E-mail: daisy_kuo@bd.com BDBiosciences Outline Basic Concept of Flow Cytometry FACSCanto II System Introduction Application
More informationImmunological Techniques in Research and Clinical Medicine. Philip L. Cohen, M.D. Chief of Rheumatology, LKSOM 10 March 2016
Immunological Techniques in Research and Clinical Medicine Philip L. Cohen, M.D. Chief of Rheumatology, LKSOM 10 March 2016 Antibodies Remarkable Tools for Research and Diagnosis You can make an antibody
More informationAMREP FLOW CYTOMETRY CORE FACILITY. Flow Cytometry Data Analysis Workshop Friday 24 th October
AMREP FLOW CYTOMETRY CORE FACILITY Flow Cytometry Data Analysis Workshop Friday 24 th October Polychromatic Flow Cytometry Data Analysis: Immunophenotyping Lymphocyte sub-populations and targeting their
More informationNavios EX FLOW CYTOMETER POWERFUL, DEPENDABLE FLOW CYTOMETRY
Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE FLOW CYTOMETRY BECAUSE EVERY EVENT MATTERS The Navios EX flow cytometer offers a solution for advanced cytometry applications with optimized workflows for
More informationVisualization of digital data Interpretation of the visual
Technical aspects of 8-color flow cytometry in the diagnosis and classification of hematopoietic malignancies Tomas Kalina!"#$%&'()*+,&$'+-./(0 *1 (2#34%-.(56(7&1+3+*&/( 8$#94&/(!:&3"(;&
More informationBD IntraSure Kit IVD. Cell fixation and permeabilization reagents. 50 tests per kit Catalog No
03/2015 23-8992-01 IVD BD IntraSure Kit Cell fixation and permeabilization reagents 50 tests per kit Catalog No. 641778 BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company.
More informationFLOW CYTOMETRY. CyAn ADP. Analyzer
FLOW CYTOMETRY CyAn ADP Analyzer Experience the Power of the CyAn ADP and its optimal performance The Power of Detection The Power of Speed The Power of Ease The CyAn ADP Analyzer is the next step in Advanced
More informationFlow Cytometry Immune Activation SOP
Flow Cytometry Immune Activation SOP Purpose This SOP standardizes the procedure for measuring immune activation of T cells using flow cytometry in ACTG Immunology Laboratories. Materials 1. 12x75mm flow
More informationDetecting human circulating endothelial cells using the Attune Acoustic Focusing Cytometer
APPLICATION NOTE Attune Acoustic Focusing Cytometer Detecting human circulating endothelial cells using the Attune Acoustic Focusing Cytometer Circulating endothelial cells (CECs) are mature cells shed
More informationPROGRAM. April 12 14, 2019 Prague, Czech Republic Czech Society for Analytical Cytometry
PROGRAM ISAC LETF Prague Cytometry Workshop 2019 April 12 14, 2019 Prague, Czech Republic www.csac.cz/en/isac-letf Czech Society for Analytical Cytometry PARTNERS / SPONSORS GENERAL INFORMATION DATE &
More informationEach question may have MULTIPLE correct answers. Select all that are correct.
Knowledge Assessment Flow Cytometry Workshop, Part 1 April 20, 2015 Each question may have MULTIPLE correct answers. Select all that are correct. 1. Tandem dyes are a. highly stable fluorophores after
More informationInhibiScreen Kinase Inhibitor Assay
InhibiScreen Kinase Inhibitor Assay Flow Cytometric assessment of efficacy of PI3Kγ, PI3Kδ, BTK and SYK pathway inhibitors using the measurement of basophil activation in human EDTA and Heparin Whole Blood.
More informationISCT Telegraft Column: Mesenchymal Stromal Cell (MSC) Product Characterization and Potency Assay Development
ISCT Telegraft Column: Mesenchymal Stromal Cell (MSC) Product Characterization and Potency Assay Development University of Wisconsin-Madison, Production Assistance for Cellular Therapies (PACT) Over the
More informationFlow Cytometric Immunophenotypic Analysis of 306 Cases of Multiple Myeloma
Hematopathology / PLASMA CELL IMMUNOPHENOTYPING Flow Cytometric Immunophenotypic Analysis of 36 Cases of Multiple Myeloma Pei Lin, MD, 1* Rebecca Owens, 1 Guido Tricot, MD, PhD, 2 and Carla S. Wilson,
More informationFlow Cytometry. Marta Argenti, PhD student. Department of Biomedical Sciences Padua
Flow Cytometry Marta Argenti, PhD student Department of Biomedical Sciences Padua 14.12.12 Flow ~ cells in motion Cyto ~ cell Metry ~ measure Physical properties: Flow Cytometry is the measurement of cells
More informationPhagocytosis Assay Kit (IgG PE)
Phagocytosis Assay Kit (IgG PE) Item No. 600540 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION
More informationFlow Cytometric Devices Draft Guidance for Industry and Food and Drug Administration Staff DRAFT GUIDANCE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 36 Flow Cytometric Devices Draft Guidance for Industry and Food and Drug Administration Staff DRAFT GUIDANCE This guidance document