Extraction of Target Fluorescence Signal from In Vivo Background Signal Using Image Subtraction Algorithm

Size: px
Start display at page:

Download "Extraction of Target Fluorescence Signal from In Vivo Background Signal Using Image Subtraction Algorithm"

Transcription

1 International Journal of Automation and Computing 9(3), June 2012, DOI: /s z Extraction of Target Fluorescence Signal from In Vivo Background Signal Using Image Subtraction Algorithm Fei Liu Xin Liu Bin Zhang Jing Bai Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing , PRC Abstract: Challenges remain in fluorescence reflectance imaging (FRI) in in vivo experiments, since the target fluorescence signal is often contaminated by the high level of background signal originated from autofluorescence and leakage of excitation light. In this paper, we propose an image subtraction algorithm based on two images acquired using two excitation filters with different spectral regions. One in vivo experiment with a mouse locally injected with fluorescein isothiocyanate (FITC) was conducted to calculate the subtraction coefficient used in our studies and to validate the subtraction result when the exact position of the target fluorescence signal was known. Another in vivo experiment employing a nude mouse implanted with green fluorescent protein (GFP) expressing colon tumor was conducted to demonstrate the performance of the employed method to extract target fluorescence signal when the exact position of the target fluorescence signal was unknown. The subtraction results show that this image subtraction algorithm can effectively extract the target fluorescence signal and quantitative analysis results demonstrate that the target-to-background ratio (TBR) can be significantly improved by 33.5 times after background signal subtraction. Keywords: Biomedical image processing, biomedical optical imaging, fluorescence, fluorescence reflectance imaging, imaging system. 1 Introduction Optical imaging techniques are emerging as new powerful modalities directed toward noninvasive, high-sensitive imaging of disease pathogenesis [1 5], drug development [6,7], and therapeutic response [8 10] in small animals in vivo [11]. Among these optical imaging methodologies, fluorescence reflectance imaging (FRI) is the most common method to record surface and subsurface fluorescence activity from entire animal, with combined simplicity of development and operation as well as high throughput [12,13]. Although FRI has gained wide applications in the field of fluorescence molecular imaging, a common issue encountered in practical applications is the background signal, which generally originates from autofluorescence of the animal (primarily from components in skin and food) especially in the visible spectrum [14], as well as the leakage of the excitation light due to imperfect fluorescent filters. In in vivo FRI experiments, the background signal may result in distorted or obscured image which significantly impairs the imaging fidelity. To overcome these limitations, various solutions have been proposed, such as employing narrow band-pass emission filters to isolate target fluorescence signal, using fluorescent probes which can be excited at wavelengths in the near-infrared (NIR) [3,15 17], and developing multi-spectral imaging techniques with the aid of special imaging systems and spectral unmixing algorithms to resolve target fluorescence signal [18 20]. However, in some practical cases, these approaches may be either infeasible or too complex. As an effective target signal extraction method, image Manuscript received July 30, 2010; revised March 9, 2012 This work was supported by National Basic Research Program of China (973 Programme) (No. 2011CB707701), National Major Scientific Instrument and Equipment Development Project (No. 2011YQ030114), National Natural Science Foundation of China (Nos , , , and ), Beijing Natural Science Foundation (No ), and Tsinghua-Yue-Yuen Medical Science Foundation. subtraction algorithm has been introduced in fluorescence imaging. However, in previously published studies, the subtraction coefficient (also called scale factor) used in the image subtraction process was determined empirically [21]. In this paper, we employed an image subtraction method with the subtraction coefficient determined by in vivo experiment to separate target fluorescence signal from background signal in FRI. In our studies, a charge-coupled device (CCD)-based fluorescence molecular imaging system has been employed to collect both fluorescence signal and background signal. A Kunming (KM) mouse injected with 20 μm fluorescein isothiocyanate (FITC) was employed to determine the subtraction coefficient in the image subtraction process. Then the image subtraction algorithm was performed to extract the target fluorescence signal originated from the locally injected FITC. Target-to-background ratio (TBR) was also analyzed to quantitatively demonstrate the performance of the used algorithm. Finally, the method was applied to detect colon tumor cells expressing green fluorescent protein (GFP) in a nude mouse. This paper is structured as follows. In Section 2, the methods used are detailed. In Section 3, in vivo experimental results are described. Finally, in Section 4, the major results of this study are concluded and future work is discussed. 2 Materials and methods 2.1 Experimental setup The system used for fluorescence signal and background signal acquisition is shown in Fig. 1, which is similar to that described in [22] except for the imaging experiments in this paper are performed in the reflectance imaging geometry. As shown in Fig. 1, the imaged animal is suspended onto

2 F. Liu et al. / Extraction of Target Fluorescence Signal from In Vivo Background Signal Using 233 an x-y translation stage (i). Signal acquisition is performed by a pixels, 70 C CCD camera (ii) (ixon DU- 897, Andor Technologies, Belfast, Northern Ireland) coupled with a 60 mm f/2.8 imaging lens (iii) (Nikon, Melville, NY, USA) placed on the opposite side of the imaged animal. A 545 ± 30 nm band-pass emission filter (iv) is employed in front of the CCD camera. A 250 W Halogen lamp (v) (7ILT250, 7-star, Beijing, PRC) equipped with a collimator lens (vi) which is used to generate a 10 cm 10 cm uniform excitation beam is mounted next to the camera, thus providing the ability to perform fluorescence imaging in the reflection geometry. Two band-pass excitation filters (vii) are used in front of the Halogen lamp for fluorescence image and background image collection, respectively. To be specific, for fluorescence signal measurements, a 465±22 nm band-pass excitation filter is used and for background signal measurements, a 425±15 nm band-pass excitation filter is used, while the emission signal is recorded with the same emission filter as discussed above. The central wavelength of the background excitation filter is chosen as 425 nm in order to be distinct from the peak excitation wavelength of the fluorophores. The imaged animal is anesthetized by an isoflurane veterinary vaporizer (VMR, Matrx, NY, USA) during in vivo imaging process. The total excitation light power delivered to the imaged animal is about 1 mw. the background excitation filter), as well as the sensitivity of the CCD camera for each wavelength used. k λex can be calculated from the relative intensities of the background signal over two spectral regions of the excitation filters λ ex and. In our studies, k λex is obtained by solving a least-squares problem: min S λex bg k λex S λbg 2 (2) where S λex bg represents the background signal in the fluorescence image S λex collected at the fluorophores excitation wavelength λ ex, which is exactly what we want to subtract from the total recorded signal to get the target fluorescence signal. After the determination of k λex, target fluorescence signal S tar f in the recorded fluorescence image S λex can be extracted according to (1). 2.3 Target-to-background ratio (TBR) In this paper, TBR is introduced to evaluate the performance of image subtraction algorithm. Typically, TBR reflects the signal intensity contrast within and outside of the region of interest (ROI). Here, ROI refers to the region where the target fluorophores are located. Target signal intensity is defined as the total pixel values within the ROI, T. Background signal intensity is defined as the total pixel values outside of the ROI, B. Thus, TBR can be calculated as follows: TBR = T B. (3) 3 Results The experimental setup of the fluorescence imaging sys- Fig. 1 tem 2.2 Image subtraction algorithm An image subtraction algorithm is employed in this paper to separate target fluorescence signal from background signal in in vivo imaging experiments. The subtraction procedure can be expressed as follows: S tar f = S λex k λex S λbg (1) where S λex denotes the fluorescence image (total recorded signal including both target fluorescence signal and background signal) collected at the fluorophores excitation wavelength λ ex, while S λbg denotes the background image collected at the background excitation wavelength. The subtraction coefficient k λex is a constant whose value mainly depends on the characteristics of the experimental setups, such as the central wavelength, the full width half maximum (FWHM) and the transmittance of the excitation filter pairs (including the fluorescence excitation filter and 3.1 Determination of subtraction coefficient To determine the coefficient for image subtraction algorithm, an 8-week-old KM mouse was employed, with hair removed from the lower part of its body. 20 μm FITCwas injected in the right leg of the mouse, and FRI was performed afterwards. Firstly, fluorescence image was acquired using the 465±22 nm band-pass excitation filter which could excite both target fluorescence signal as well as background signal. Then, the 425 ± 15 nm band-pass background excitation filter was used in place of the 465 ± 22 nm filter to collect background image which contains background signal only. The exposure time was set to 2 s and 4 4 CCD binning was used in this imaging experiment. Finally, the subtraction coefficient k λex can be calculated from the relative intensities of the background signal over the spectral regions of the two excitation filters. As the relative intensities of the background signals may vary slightly in different regions of the mouse torso, in our studies, 10 regions (each included pixels) in the background region were randomly selected and corresponding subtraction coefficients were calculated according to (2), respectively. The final subtraction coefficient was determined by the mean of the 10 subtraction coefficients. Fig. 2 depicts 10 different regions to calculate subtraction coefficient, as outlined by the red rectangles in the images. The first row illustrates the 10 selected regions in the fluo-

3 234 International Journal of Automation and Computing 9(3), June 2012 Fig. 2 Different regions to calculate the subtraction coefficient. (a) (j) Ten different regions in the fluorescence image; (k) (t) Corresponding regions in the background image (The red rectangles indicate the outline of the selected regions, and the green arrow in (a) indicates the injection position of FITC) Fig. 3 Image subtraction process. (a) White light image of the mouse (The green arrow indicates the injection position of FITC); (b) Fluorescence image collected by the 465 ± 22 nm excitation filter; (c) Background image collected by the 425 ± 15 nm background excitation filter; (d) Target fluorescence signal separated from background signal (The red curves in (b) and (d) outline the ROI where FITC was injected) Table 1 Calculation of subtraction coefficient k λex Region Mean Standard deviation k λex rescence image and the second row illustrates corresponding regions in the background image. The green arrow in Fig. 2 (a) indicates the injection position of FITC. As shown in Table 1, the subtraction coefficients vary slightly from each other. The final subtraction coefficient was determined as k λex =3.71 according to the mean of the 10 subtraction coefficients. Subtraction coefficients between other excitation filter pairs can be obtained using similar method but are not referred to herein. 3.2 In vivo study 1 Since the subtraction coefficient k λex has been determined, image subtraction could be conducted based on (1) to extract target FITC fluorescence signal from background signal in the previously described KM mouse. Here, as FITC was locally injected, the injection region was considered as the ROI. Thus, target fluorescence signal T equals to the total pixel values within the ROI, and background signal B equals to the total pixel values outside of the ROI. TBRs before and after image subtraction were both calculated according to (3), in order to quantitatively analyze the ability of our method to extract target fluorescence signal and remove background signal. The white light image of the mouse with a green arrow indicating the injection position of FITC is depicted in Fig. 3 (a). Fig. 3 (b) shows the collected fluorescence image including both target fluorescence signal and background signal, and Fig. 3 (c) shows the background image collected at the background excitation wavelength. The red curve in Fig. 3 (b) indicates the ROI where FITC was injected. From Fig. 3 (b), we can find that the intensity of background signal outside of the ROI is relatively stronger in the original fluorescence image. After image subtraction, target fluorescence signal within the ROI is effectively enhanced, as shown in Fig. 3 (d). TBRs analysis results (see Table 2) further demonstrate the performance of the image subtraction algorithm quantitatively. The results suggest that the contrast between the target fluorescence signal and the background signal has been improved by 33.5 times after applying the image subtraction algorithm. Table 2 TBRs before and after image subtraction Before image subtraction After image subtraction TBR In vivo study 2 To further demonstrate the ability of our method to effectively remove background signal and extract target fluorescence signal in obscured fluorescence image when the exact location of target fluorescence signal is unknown, we performed another in vivo study employing a nude mouse implanted with GFP-expressing colon tumor. Firstly, fluor-

4 F. Liu et al. / Extraction of Target Fluorescence Signal from In Vivo Background Signal Using 235 Fig. 4 Image subtraction for a nude mouse bearing GFP-expressing colon tumor: (a) White light image of the mouse; (b) Fluorescence image collected by the 465 ± 22 nm excitation filter; (c) Background image collected by the 425 ± 15 nm background excitation filter; (d) Target fluorescence signal separated from background signal (The green arrow indicates the target tumor fluorescence signal in the lower abdomen) escence image was acquired using the 465±22 nm band-pass excitation filter which could excite both target fluorescence signal as well as background signal. Then, the 425 ± 15 nm band-pass background excitation filter was used in place of the 465 ± 22 nm filter to collect background image which contained background signal only. The exposure time was set to 5 s and 1 1 CCD binning was used in this experiment. Finally, image subtraction was conducted based on (1). As the same experimental setup was used in both in vivo studies, the same subtraction coefficient k λex =3.71 determined in Section 3.1 was employed here. The white light image of the GFP-expressing colon tumor mouse is depicted in Fig. 4 (a). Fig. 4 (b) shows the collected fluorescence image including both target fluorescence signal and background signal, and Fig. 4 (c) shows the background image collected at the background excitation wavelength. Since the exact position of the tumor is unknown, and the intensity of fluorescence signal is weak, it is difficult to distinguish the target tumor fluorescence just from the fluorescence image as shown in Fig. 4 (b). However, after applying image subtraction algorithm, the target tumor fluorescence signal in the lower abdomen is effectively extracted, as indicated by the green arrow in Fig. 4 (d). 4 Conclusions and future work Challenges remain in FRI of surface and subsurface fluorescence activity in small animals in vivo, since the target fluorescence signal is often contaminated by the high level of background signal originated from autofluorescence and leaked excitation light. This may significantly compromise the TBR and imaging fidelity of the FRI modality. Thus, an effective technique to separate target fluorescence signal from background signal is critical. In this paper, we mainly studied an image subtraction algorithm which is conducted based on two images collected by two excitation filters over different spectral regions. The in vivo imaging results show that the proposed method can effectively extract the target fluorescence signal shielded in high level of background signal, and the contrast between the target fluorescence signal and background signal can be greatly improved after background subtraction. The problem of background signal contamination also exists in the study of fluorescence molecular tomography (FMT) [23,24]. In the future, this feasible and effective image subtraction algorithm could also be incorporated into FMT studies for the reduction of background noise and improvement of reconstruction quality. References [1] R. A. Sheth, R. Upadhyay, L. Stangenberg, R. Sheth, R. Weissleder, U. Mahmood. Improved detection of ovarian cancer metastases by intraoperative quantitative fluorescence protease imaging in a pre-clinical model. Gynecologic Oncology, vol. 112, no. 3, pp , [2] P. Puvanakrishnan, J. Park, P. Diagaradjane, J. A. Schwartz, C. L. Coleman, K. L. Gill-Sharp, K. L. Sang, J. D. Payne, S. Krishnan, J. W. Tunnell. Near-infrared narrowband imaging of gold/silica nanoshells in tumors. Journal of Biomedical Optics, vol. 14, no. 2, , [3] N. C. Deliolanis, J. Dunham, T. Wurdinger, J. L. Figueiredo, B. A. Tannous, V. Ntziachristos. In-vivo imaging of murine tumors using complete-angle projection fluorescence molecular tomography. Journal of Biomedical Optics, vol. 14, no. 3, , [4] J. Haller, D. Hyde, N. Deliolanis, R. de Kleine, M. Niedre, V. Ntziachristos. Visualization of pulmonary inflammation using noninvasive fluorescence molecular imaging. Journal of Applied Physiology, vol. 104, no. 3, pp , [5] E.L.Kaijzel,G.vanderPluijm,C.W.Lowik.Whole-body optical imaging in animal models to assess cancer development and progression. Clinical Cancer Research, vol. 13, no. 12, pp , [6] K. Licha, C. Olbrich. Optical imaging in drug discovery and diagnostic applications. Advanced Drug Delivery Reviews, vol. 57, no. 8, pp , [7] M. Rudin, R. Weissleder. Molecular imaging in drug discovery and development. Nature Reviews Drug Discovery, vol. 2, no. 2, pp , [8] X. Montet, J. L. Figueiredo, H. Alencar, V. Ntziachristos, U. Mahmood, R. Weissleder. Tomographic fluorescence imaging of tumor vascular volume in mice. Radiology, vol. 242, no. 3, pp , [9] X. Montet, V. Ntziachristos, J. Grimm, R. Weissleder. Tomographic fluorescence mapping of tumor targets. Cancer Research, vol. 65, no. 14, pp , [10] V. Ntziachristos, E. A. Schellenberger, J. Ripoll, D. Yessayan, E. Graves, A. J. Bogdanov, L. Josephson, R. Weissleder. Visualization of antitumor treatment by means of fluorescence molecular tomography with an annexin v- cy5.5 conjugate. Proceedings of the National Academy of Sciences of the United States of America, vol. 101, no. 33, pp , [11] G. D. Luker, K. E. Luker. Optical imaging: Current applications and future directions. Journal of Nuclear Medicine, vol. 49, no. 1, pp. 1 4, [12] V. Ntziachristos. Fluorescence molecular imaging. Annual Review of Biomedical Engineering, vol. 8, no. 1, pp. 1 33, [13] V. Ntziachristos, J. Ripoll, L. V. Wang, R. Weissleder. Looking and listening to light: The evolution of whole-body photonic imaging. Nature Biotechnology, vol. 23, no. 3, pp , 2005.

5 236 International Journal of Automation and Computing 9(3), June 2012 [14] A. Garofalakis, G. Zacharakis, H. Meyer, E. N. Economou, C. Mamalaki, J. Papamatheakis, D. Kioussis, V. Ntziachristos, J. Ripoll. Three-dimensional in vivo imaging of green fluorescent protein-expressing T cells in mice with noncontact fluorescence molecular tomography. Molecular Imaging, vol. 6, no. 2, pp , [15] E. I. Altinoglu, T. J. Russin, J. M. Kaiser, B. M. Barth, P. C. Eklund, M. Kester, J. H. Adair. Near-infrared emitting fluorophore-doped calcium phosphate nanoparticles for in vivo imaging of human breast cancer. ACS Nano, vol.2, no. 10, pp , [16] K. E. Adams, S. Ke, S. Kwon, F. Liang, Z. Fan, Y. Lu, K. Hirschi, M. E. Mawad, M. A. Barry, E. M. Sevick-Muraca. Comparison of visible and near-infrared wavelength-excitable fluorescent dyes for molecular imaging of cancer. Journal of Biomedical Optics, vol. 12, no. 2, , [17] T. A. Zdobnova, S. G. Dorofeev, P. N. Tananaev, R. B. Vasiliev, T. G. Balandin, E. F. Edelweiss, O. A. Stremovskiy, I. V. Balalaeva, I. V. Turchin, E. N. Lebedenko, V. P. Zlomanov, S. M. Deyev. Fluorescent immunolabeling of cancer cells by quantum dots and antibody scfv fragment. Journal of Biomedical Optics, vol. 14, no. 2, , [18] J. R. Mansfield, K. W. Gossage, C. C. Hoyt, R. M. Levenson. Autofluorescence removal, multiplexing, and automated analysis methods for in-vivo fluorescence imaging. Journal of Biomedical Optics, vol. 10, no. 4, , [19] H. Xu, B. W. Rice. In-vivo fluorescence imaging with a multivariate curve resolution spectral unmixing technique. Journal of Biomedical Optics, vol. 14, no. 6, , [20] Y. Koyama, Y. Hama, Y. Urano, D. M. Nguyen, P. L. Choyke, H. Kobayashi. Spectral fluorescence molecular imaging of lung metastases targeting HER2/neu. Clinical Cancer Research, vol. 13, no. 10, pp , [21] N. C. Deliolanis, T. Wurdinger, L. Pike, B. A. Tannous, X. O. Breakefield, R. Weissleder, V. Ntziachristos. In vivo tomographic imaging of red-shifted fluorescent proteins. Biomedical Optics Express, vol. 2, no. 4, pp , [22] F. Liu, X. Liu, D. Wang, B. Zhang, J. Bai. A parallel excitation based fluorescence molecular tomography system for whole-body simultaneous imaging of small animals. Annals of Biomedical Engineering, vol. 38, no. 11, pp , [23] M. Gao, G. Lewis, G. M. Turner, A. Soubret, V. Ntziachristos. Effects of background fluorescence in fluorescence molecular tomography. Applied Optics, vol. 44, no. 26, pp , [24] S. Psycharakis, G. Zacharakis, A. Garofalakis, R. Favicchio, J. Ripoll. Autofluorescence removal from fluorescence tomography data using multispectral imaging. In Proceedings of SPIE-OSA Biomedical Optics, Munich, Germany, vol. 6626, paper , Fei Liu received the bachelor degree in biomedical engineering from Zhejiang University, Zhejiang, PRC in She is currently a Ph. D. candidate in the Department of Biomedical Engineering, Tsinghua University, Beijing, PRC. Her research interests include fluorescence molecular tomography for small animal imaging. l-f08@mails.tsinghua.edu.cn Xin Liu received the bachelor and master degrees from the Fourth Military Medical University, Xi an, PRC in 2001 and 2006, respectively. He is now a Ph. D. candidate in the Department of Biomedical Engineering, Tsinghua University, Beijing, PRC. His research interests include fluorescence molecular tomography and medical image processing. xin-liu08@mails.tsinghua.edu.cn Bin Zhang received the master degree in mechanical and electronic engineering from University of Science and Technology of China in From 2007 to 2009, he was a research assistant in Shenzhen Institute of Advanced Integration Technology, Chinese Academy of Sciences, PRC. He is now a Ph. D. candidate in the Department of Biomedical Engineering, Tsinghua University, Beijing, PRC. His research interests include fluorescence molecular tomography for small animal. zhbin2008@gmail.com Jing Bai received the M. Sc. and Ph. D. degrees from Drexel University, Philadelphia, PA, USA in 1983 and 1985, respectively. From 1985 to 1987, she was a research associate and assistant professor at the Biomedical Engineering and Science Institute, Drexel University. In 1988, 1991, and 2000, she became an associate professor, professor, and Cheung Kong chair professor at the Department of Biomedical Engineering, Tsinghua University, Beijing, PRC. Since 1997, she has been an associate editor for IEEE Transactions on Information Technology in Biomedicine. She has authored or coauthored ten books and more than 300 journal papers. Her research interests include mathematical modeling and simulation of cardiovascular system, optimization of cardiac assist devices, medical ultrasound, telemedicine, home health care network and home monitoring devices, and infrared imaging. deabj@tsinghua.edu.cn (Corresponding author)

Ilya Turchin. Institute of Applied Physics of the RAS, Nizhny Novgorod, Russia.

Ilya Turchin. Institute of Applied Physics of the RAS, Nizhny Novgorod, Russia. Fluorescence 3D imaging of small animals Ilya Turchin Institute of Applied Physics of the RAS, Nizhny Novgorod, Russia ilya@ufp.appl.sci-nnov.ru http://www.bioimaging.ru German-Russian Forum Biotechnology

More information

Advanced preclinical optical imaging. Preclinical in vivo imaging. IVIS Spectrum

Advanced preclinical optical imaging. Preclinical in vivo imaging. IVIS Spectrum IVIS Spectrum P R O D U C T N O T E Preclinical in vivo imaging Key Features High Sensitivity in vivo fluorescence and bioluminescence imaging 3D tomographic reconstruction Absolute calibration High throughput

More information

1st Faculty of Medicine, Charles University in Prague Center for Advanced Preclinical Imaging (CAPI)

1st Faculty of Medicine, Charles University in Prague Center for Advanced Preclinical Imaging (CAPI) ADVANTAGES Optical Imaging OI Optical Imaging is based on the detection of weak light by a highly sensitive and high resolution CCD camera DISADVANTAGES High sensitivity Limited penetration depth Easy

More information

Widefield Microscopy Bleed-Through

Widefield Microscopy Bleed-Through In widefield microscopy the excitation wavelengths which illuminate the sample, and the emission wavelengths which reach the CCD camera are selected throughout a filter cube. A filter cube consists of

More information

Multiplexed 3D FRET imaging in deep tissue of live embryos Ming Zhao, Xiaoyang Wan, Yu Li, Weibin Zhou and Leilei Peng

Multiplexed 3D FRET imaging in deep tissue of live embryos Ming Zhao, Xiaoyang Wan, Yu Li, Weibin Zhou and Leilei Peng Scientific Reports Multiplexed 3D FRET imaging in deep tissue of live embryos Ming Zhao, Xiaoyang Wan, Yu Li, Weibin Zhou and Leilei Peng 1 Supplementary figures and notes Supplementary Figure S1 Volumetric

More information

Basic principles of quantification using optical techniques

Basic principles of quantification using optical techniques Contents Basic principles of quantification using optical techniques Adrian Taruttis Helmholtz Zentrum München Chair for Biological Imaging Technische Universität München Light/ tissue interactions Planar

More information

Compensation: Fundamental Principles

Compensation: Fundamental Principles Flow Cytometry Seminar Series 2017 : Fundamental Principles Spillover correction in multicolor flow cytometry 28.02.2017 http://www.cytometry.uzh.ch Contents Fluorescence and its detection Absorption and

More information

Pre-Clinical Optical Molecular Imager

Pre-Clinical Optical Molecular Imager Pre-Clinical Optical Molecular Imager ART Advanced Research Technologies Inc. 2300 Alfred-Nobel Blvd. Saint-Laurent, QC Canada, H4S 2A4 T 514.832.0777 / 1.888.278.7888 F 514.832.0778 E info@art.ca Table

More information

TARGETED IMAGING. Maureen Chan and Ruwani Mahathantila

TARGETED IMAGING. Maureen Chan and Ruwani Mahathantila TARGETED IMAGING Maureen Chan and Ruwani Mahathantila Overview 2 Introduction to fluorescent imaging Fluorescent agents Quantum Dots Physical properties How QDs work In Vivo QD imaging Future Video What

More information

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING The NEWTON s protocol driven image acquisition is as quick as it is intuitive: adjust your exposure, save, print or quantify.

More information

Microelectromechanical systems scanning-mirrorbased handheld probe for fluorescence molecular tomography

Microelectromechanical systems scanning-mirrorbased handheld probe for fluorescence molecular tomography Microelectromechanical systems scanning-mirrorbased handheld probe for fluorescence molecular tomography Bin He, 1 Lei Xi, 1 Sean R. Samuelson, 2 Huikai Xie, 2 Lily Yang, 3 and Huabei Jiang 1, * 1 Department

More information

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING The NEWTON s protocol driven image acquisition is as quick as it is intuitive: adjust your exposure, save, print or quantify.

More information

PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland

PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland AD Award Number: W81XWH-07-1-0231 TITLE: Spectroscopic Photoacoustic Tomography of Prostate Cancer PRINCIPAL INVESTIGATOR: Xueding Wang CONTRACTING ORGANIZATION: University Of Michigan Ann Arbor, MI 48109-1274

More information

Confocal Microscopy Analyzes Cells

Confocal Microscopy Analyzes Cells Choosing Filters for Fluorescence A Laurin Publication Photonic Solutions for Biotechnology and Medicine November 2002 Confocal Microscopy Analyzes Cells Reprinted from the November 2002 issue of Biophotonics

More information

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING SMART IMAGING SYSTEM The NEWTON 7.0 system combines high sensitivity with advanced animal-handling features and userfriendly

More information

Development of a Red Fluorescent Labeled Agent for Assessing HER2 Expression

Development of a Red Fluorescent Labeled Agent for Assessing HER2 Expression APPLICATION NOTE Development of a Red Fluorescent Labeled Agent for Assessing HER2 Expression HER2Sense 645 Author Jeffrey D. Peterson, Ph.D. PerkinElmer, Inc. Waltham, MA USA Abstract Despite the clinical

More information

Translational Multimodality Optical Imaging

Translational Multimodality Optical Imaging Translational Multimodality Optical Imaging Fred S. Azar Xavier Intes Editors 0 ARTECH H O U S E BOSTON LONDON artechhouse.com Contents Foreword Preface xv xvii CHAPTER1 Introduction to Clinical Optical

More information

Research Article Normalized Born Approximation-Based Two-Stage Reconstruction Algorithm for Quantitative Fluorescence Molecular Tomography

Research Article Normalized Born Approximation-Based Two-Stage Reconstruction Algorithm for Quantitative Fluorescence Molecular Tomography Journal of Electrical and Computer Engineering Volume 12, Article ID 838967, 9 pages doi:.11/12/838967 Research Article Normalized Born Approximation-Based Two-Stage Reconstruction Algorithm for Quantitative

More information

Innovations To Meet Your Needs

Innovations To Meet Your Needs Innovations To Meet Your Needs Cooled CCD Camera 1340 x 1037 pixel resolution for greatest image quality 12-bit precision provides 3 orders of linear dynamic range Windows and Power Macintosh Software

More information

Supplementary Figures

Supplementary Figures Supplementary Figures Supplementary Figure S1. In vitro determination of the detection limit of vanco-800cw (a) Specificity of vanco-800cw for different clinical bacterial isolates. The in vitro imaging

More information

Non-negative Matrix Factorization under sparsity constraints to unmix in vivo spectrally resolved

Non-negative Matrix Factorization under sparsity constraints to unmix in vivo spectrally resolved Non-negative Matrix Factorization under sparsity constraints to unmix in vivo spectrally resolved acquisitions Anne-Sophie Montcuquet, Lionel Herve, Fabrice Navarro, Jean-Marc Dinten, Jerome Mars To cite

More information

Unrivalled Optical Imaging solutions

Unrivalled Optical Imaging solutions Unrivalled Optical Imaging solutions high throughput high resolution x-ray TOMOFLUO multispectral analysis 3D And beyound... bioluminescence and fluorescence Imaging systems Real-time imaging capability

More information

Microelectromechanical systems scanning-mirror-based handheld probe for fluorescence molecular tomography

Microelectromechanical systems scanning-mirror-based handheld probe for fluorescence molecular tomography Microelectromechanical systems scanning-mirror-based handheld probe for fluorescence molecular tomography Bin He, University of Florida Lei Xi, University of Florida Sean R. Samuelson, University of Florida

More information

Sapphire. Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING

Sapphire. Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING Sapphire Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING Breakthrough image capture and analysis The Sapphire Biomolecular Imager is a next generation laser scanning system that provides

More information

HYPERSPECTRAL MICROSCOPE PLATFORM FOR HIGHLY MULTIPLEX BIOLOGICAL IMAGING. Marc Verhaegen

HYPERSPECTRAL MICROSCOPE PLATFORM FOR HIGHLY MULTIPLEX BIOLOGICAL IMAGING. Marc Verhaegen HYPERSPECTRAL MICROSCOPE PLATFORM FOR HIGHLY MULTIPLEX BIOLOGICAL IMAGING Marc Verhaegen CMCS, MONTREAL, MAY 11 th, 2017 OVERVIEW Hyperspectral Imaging Multiplex Biological Imaging Multiplex Single Particle

More information

Experts in Femtosecond Laser Technology. DermaInspect. Non-invasive multiphoton tomography of human skin

Experts in Femtosecond Laser Technology. DermaInspect. Non-invasive multiphoton tomography of human skin Experts in Femtosecond Laser Technology DermaInspect Non-invasive multiphoton tomography of human skin In vivo optical biopsies with subcellular spatial resolution based on near infrared femtosecond laser

More information

ibox Explorer TM Imaging Microscope

ibox Explorer TM Imaging Microscope ibox Explorer TM Imaging Microscope Visible to NIR In Vivo Imaging for Macro to Micro Detection of Fluorescent Markers in Small Animals Capture images with the high sensitivity, cooled CCD camera and optics,

More information

Spectroscopy and Imaging IV

Spectroscopy and Imaging IV PROGRESS IN BIOMEDICAL OPTICS AND IMAGING Vol. 16 No. 55 Clinical and Biomedical Spectroscopy and Imaging IV J. Quincy Brown Volker Decked Edifors 22-24 June 2015 Munich, Germany Sponsored by SPIE (United

More information

Fluorescence Microscopy. Terms and concepts to know: 10/11/2011. Visible spectrum (of light) and energy

Fluorescence Microscopy. Terms and concepts to know: 10/11/2011. Visible spectrum (of light) and energy Fluorescence Microscopy Louisiana Tech University Ruston, Louisiana Microscopy Workshop Dr. Mark DeCoster Associate Professor Biomedical Engineering 1 Terms and concepts to know: Signal to Noise Excitation

More information

Study Guide Imaging Physics and Biophysics for the Master-Study Programmes

Study Guide Imaging Physics and Biophysics for the Master-Study Programmes Study Guide Imaging Physics and Biophysics for the Master-Study Programmes Imaging Physics is one of the main areas of research of the Faculty for Physics and Astronomy at the Julius-Maximilians-University

More information

EDUCATION EXPERIMENT. Fluorescence of an Unknown Fluorophore. Introduction.

EDUCATION EXPERIMENT. Fluorescence of an Unknown Fluorophore. Introduction. EDUCATION EXPERIMENT Fluorescence of an Unknown Fluorophore Introduction www.oceanoptics.com info@oceanoptics.com Fluorescent tags have become a powerful tool in research and diagnostics, capable of revealing

More information

The analysis of fluorescence microscopy images for FRET detection

The analysis of fluorescence microscopy images for FRET detection The analysis of fluorescence microscopy images for FRET detection Ela Claridge, Dale J. Powner and Michael J.O. Wakelam School of Computer Science, The University of Birmingham B5 2TT Institute for Cancer

More information

Nayar Prize I Quarterly Progress Report (Quarters 2&3) August, 2016

Nayar Prize I Quarterly Progress Report (Quarters 2&3) August, 2016 Nayar Prize I Quarterly Progress Report (Quarters 2&3) August, 2016 Project: ADEPT Cancer Imager Team: Ken Tichauer, Jovan Brankov, Raju Mehta Students: Lagnojita Sinha, Xiaochun Xu Progress Summary Since

More information

Dino-Lite knowledge & education. Fluorescence Microscopes

Dino-Lite knowledge & education. Fluorescence Microscopes Dino-Lite knowledge & education Fluorescence Microscopes Dino-Lite Fluorescence models Smallest fluorescence microscope in the world Revolution to biomedical and educational applications Flexible Easy

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION VOLUME: 1 ARTICLE NUMBER: 0011 In the format provided by the authors and unedited. In situ Activation of Platelets with Checkpoint Inhibitors for Post-Surgical Cancer Immunotherapy Chao Wang 1, 2, Wujin

More information

Photoacoustic imaging of vascular networks in transgenic mice

Photoacoustic imaging of vascular networks in transgenic mice Photoacoustic imaging of vascular networks in transgenic mice J.G. Laufer 1, J.O. Cleary 1,2, E.Z. Zhang 1, M.F. Lythgoe 2, P.C. Beard 1 1. Department of Medical Physics and Bioengineering, University

More information

Spectral Separation of Multifluorescence Labels with the LSM 510 META

Spectral Separation of Multifluorescence Labels with the LSM 510 META Microscopy from Carl Zeiss Spectral Separation of Multifluorescence Labels with the LSM 510 META Indians living in the South American rain forest can distinguish between almost 200 hues of green in their

More information

Sapphire. Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING

Sapphire. Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING Sapphire Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING Breakthrough image capture and analysis The Sapphire Biomolecular Imager is a next generation laser scanning system that provides

More information

SUPPLEMENTARY FIGURES

SUPPLEMENTARY FIGURES SYNERGISTIC STRATEGY FOR MULTICOLOR TWO-PHOTON MICROSCOPY: APPLICATION TO THE ANALYSIS OF GERMINAL CENTER REACTIONS IN VIVO ASYLKHAN RAKHYMZHAN, RUTH LEBEN, HANNA ZIMMERMANN, ROBERT GÜNTHER, PEGGY MEX,

More information

Intraoperative Fluorescence Surgical Goggle

Intraoperative Fluorescence Surgical Goggle Intraoperative Fluorescence Surgical Goggle Ruogu Qin Abstract Background Tumor surgery is a great challenge to surgeons. Due to their disseminated characteristic, the small and varied foci and blurred

More information

Supporting information

Supporting information Supporting information Large Hollow Cavity Luminous Nanoparticles with Near-Infrared Persistent Luminescence and Tunable Sizes for Tumor Afterglow Imaging and Chemo/Photodynamic Therapies Jun Wang, Jinlei

More information

Applicability of Hyperspectral Fluorescence Imaging to Mineral Sorting

Applicability of Hyperspectral Fluorescence Imaging to Mineral Sorting Institute of Industrial Information Technology Applicability of Hyperspectral Fluorescence Imaging to Mineral Sorting Optical Characterization of Materials, March 19, 2015 Sebastian Bauer, M.Sc. (Head:

More information

Design for Manufacturability (DFM) in the Life Sciences

Design for Manufacturability (DFM) in the Life Sciences T E C H N I C A L N O T E Design for Manufacturability (DFM) in the Life Sciences Fluorescence Spectroscopy Product Platform Realized with TracePro TM Suite of Opto-Mechanical Design Software Tools Authors:

More information

In situ semi-quantitative assessment of single cell viability by resonance

In situ semi-quantitative assessment of single cell viability by resonance Electronic Supplementary Material (ESI) for Chemical Communications. This journal is The Royal Society of Chemistry 2018 Electronic Supplementary Information (ESI) In situ semi-quantitative assessment

More information

High-Throughput In Vivo Bioluminescence Imaging System

High-Throughput In Vivo Bioluminescence Imaging System IVIS SpectrumBL P R O D U C T N O T E Pre-clinical in vivo imaging Key Features Ultra high-sensitivity to support in vivo bioluminescence, chemiluminescence and Cerenkov imaging High-throughput (10 mice)

More information

Biomedical Applications of Molecular Spectroscopy

Biomedical Applications of Molecular Spectroscopy Biomedical Applications of Molecular Spectroscopy Mike Kayat B&W Tek, Inc 19 Shea Way Newark, DE 19713 United States of America +1 302 368 7824 mikek@bwtek.com 1 Overview Molecular spectroscopy is a large

More information

TITLE: Early Detection of Breast Cancer by Fluorescence Molecular Tomography

TITLE: Early Detection of Breast Cancer by Fluorescence Molecular Tomography AD Award Number: W81XWH-04-1-0239 TITLE: Early Detection of Breast Cancer by Fluorescence Molecular Tomography PRINCIPAL INVESTIGATOR: Vasilis Ntziachristos, Ph.D. CONTRACTING ORGANIZATION: Massachusetts

More information

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging Introduction In this application note, we will discuss the application of quantum dots in fluorescence imaging, both

More information

Evaluating Microplate Detection Instruments

Evaluating Microplate Detection Instruments AppNote Evaluating Microplate Detection Instruments Introduction Important features to consider when evaluating a microplate reader are the following: sensitivity, dynamic range, throughput, integration

More information

Supporting Information

Supporting Information Supporting Information Dual-Modal Probe based on Polythiophene Derivative for Pre- and Intraoperative Mapping of Lymph Nodes by SPECT/Optical Imaging Bing Jia,,, Xin Zhang,, Bing Wang, #, Muhua Chen, Fengting

More information

CHEMOMETRICAL ANALYSIS OF ENDOMETRIAL TISSUE FLUORESCENCE SPECTRA

CHEMOMETRICAL ANALYSIS OF ENDOMETRIAL TISSUE FLUORESCENCE SPECTRA CHEMOMETRICAL ANALYSIS OF ENDOMETRIAL TISSUE FLUORESCENCE SPECTRA A.Vaitkuviene a *, E.Auksorius a, D. Fuchs b, V.Gavriushin a a Vilnius University, Institute of Materials Science and Applied Research,

More information

Supplementary Figures

Supplementary Figures Supplementary Figures Supplementary Figur e 1. DLS analyses of DSPE PEG 2000 Amine DC(8,9)PC LM (a) immediately after its preparation and (b) after 3 days. Supplementary Figure 2. Particle size distribution

More information

More on fluorescence

More on fluorescence More on fluorescence Last class Fluorescence Absorption emission Jablonski diagrams This class More on fluorescence Common fluorophores Jablonski diagrams to spectra Properties of fluorophores Excitation

More information

Introduction to Radiation Therapy : Basics, and Recent Technologies

Introduction to Radiation Therapy : Basics, and Recent Technologies Introduction to Radiation Therapy : Basics, and Recent Technologies Pusan National University Undergraduate Student Seminar Justin. C. Park (Chun Joo Park) Dept. of Electrical and Computer Engineering

More information

Superstructure Fiber Bragg Grating based Sensors

Superstructure Fiber Bragg Grating based Sensors ABHIYANTRIKI based Sensors An International Journal of Engineering & Technology (A Peer Reviewed & Indexed Journal) Vol. 3, No. 5 (May, 2016) http://www.aijet.in/ eissn: 2394-627X Ashima Sindhu Mohanty*

More information

Supplementary Information

Supplementary Information Supplementary Information Trapping and Detection of Nanoparticles and Cells Using a Parallel Photonic Nanojet Array Yuchao Li, Hongbao Xin, Xiaoshuai Liu, Yao Zhang, Hongxiang Lei*, and Baojun Li* State

More information

Application Note # AP0109 Jan 2012 In Vivo Fluorescence Imaging of Tumor Proliferation Using Pre-labeled Cancer Cells and a Targeted Probe

Application Note # AP0109 Jan 2012 In Vivo Fluorescence Imaging of Tumor Proliferation Using Pre-labeled Cancer Cells and a Targeted Probe Application Note # AP0109 Jan 2012 In Vivo Fluorescence Imaging of Tumor Proliferation Using Pre-labeled Cancer Cells and a Targeted Probe Sean Patrick Orton, 1 Joshua D. Morris, 2 Bryan A. Smith, 2 and

More information

Flow Cytometry - The Essentials

Flow Cytometry - The Essentials Flow Cytometry - The Essentials Pocket Guide to Flow Cytometry: 1. Know your Cytometer 2. Understanding Fluorescence and Fluorophores 3. Gating Process 4. Controls 5. Optimization 6. Panel Building 7.

More information

Biophotonics?? Biophotonics. technology in biomedical engineering. Advantages of the lightwave

Biophotonics?? Biophotonics. technology in biomedical engineering. Advantages of the lightwave Biophotonics - Imaging: X-ray, OCT, polarimetry, DOT, TIRF, photon migration, endoscopy, confocal microscopy, multiphoton microscopy, multispectral imaging - Biosensing: IR spectroscopy, fluorescence,

More information

Fast, three-dimensional super-resolution imaging of live cells

Fast, three-dimensional super-resolution imaging of live cells Nature Methods Fast, three-dimensional super-resolution imaging of live cells Sara A Jones, Sang-Hee Shim, Jiang He & Xiaowei Zhuang Supplementary Figure 1 Supplementary Figure 2 Supplementary Figure 3

More information

PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland

PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland AD Award Number: W81XWH-07-1-0231 TITLE: Spectroscopic Photoacoustic Tomography of Prostate Cancer PRINCIPAL INVESTIGATOR: Xueding Wang CONTRACTING ORGANIZATION: University Of Michigan Ann Arbor, MI 48109-1274

More information

Deliverable 2.1: Definition of paradigms representing exemplary breast lesions cases

Deliverable 2.1: Definition of paradigms representing exemplary breast lesions cases Project title: Smart Optical and Ultrasound Diagnostics of Breast Cancer Grant Agreement: 731877 Call identifier: H2020-ICT-2016-1 Topic: ICT-29-2016 Photonics KET 2016 Deliverable 2.1: Definition of paradigms

More information

PHOTONICS APPLIED: BIOPHOTONICS: Molecules can't hide from the newest in-vivo imaging techniques

PHOTONICS APPLIED: BIOPHOTONICS: Molecules can't hide from the newest in-vivo imaging techniques Page 1 of 6 PHOTONICS APPLIED: BIOPHOTONICS: Molecules can't hide from the newest in-vivo imaging techniques Close Optical molecular imaging (OMI) a marriage between various optical imaging techniques

More information

School of Chemical and Life Sciences, Nanyang Polytechnic, Singapore *Corresponding author

School of Chemical and Life Sciences, Nanyang Polytechnic, Singapore *Corresponding author 0 Differential Effect of Solar Light in Increasing the Toxicity of Silver and Titanium Dioxide Nanoparticles to a Fish Cell Line and Zebrafish Embryos Saji George # *, Hannah Gardner, Seng Eng Khuan, Hengky

More information

Electronic Supplementary Information

Electronic Supplementary Information Electronic Supplementary Material (ESI) for Chemical Communications. This journal is The Royal Society of Chemistry 2017 Electronic Supplementary Information Nitrogen-doped graphene quantum dots coupled

More information

Optical Observation - Hyperspectral Characterization of Nano-scale Materials In-situ

Optical Observation - Hyperspectral Characterization of Nano-scale Materials In-situ Optical Observation - Hyperspectral Characterization of Nano-scale Materials In-situ Research at the nanoscale is more effective, when research teams can quickly and easily observe and characterize a wide

More information

Localization Microscopy

Localization Microscopy Localization Microscopy Theory, Sample Prep & Practical Considerations Patrina Pellett & Ann McEvoy Applications Scientist GE Healthcare, Cell Technologies May 27 th, 2015 Localization Microscopy Talk

More information

Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288

Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288 Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting Shoreline Community College BIOL 288 Flow Cytometry What is Flow Cytometry? Measurement of cells or particles

More information

58 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 27, NO. 1, JANUARY 2008

58 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 27, NO. 1, JANUARY 2008 58 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 27, NO. 1, JANUARY 2008 A Comparison Between a Time Domain and Continuous Wave Small Animal Optical Imaging System Shay Keren, Olivier Gheysens, Craig S. Levin,

More information

Quantum dots in Molecular Imaging

Quantum dots in Molecular Imaging Quantum dots in Molecular Imaging Ivo Que 1 Introduction Quantum dots (Qdots ) are nanoparticles exhibiting fluorescent properties that can be used for cell staining. In the early 1980s the first quantum

More information

Photoacoustic Imaging in Biomedicine Critical Review by Saurabh Vyas Group 9: Interventional Photoacoustic Ultrasound CIS II: 600.

Photoacoustic Imaging in Biomedicine Critical Review by Saurabh Vyas Group 9: Interventional Photoacoustic Ultrasound CIS II: 600. Photoacoustic Imaging in Biomedicine Critical Review by Saurabh Vyas Group 9: Interventional Photoacoustic Ultrasound CIS II: 600.446, Spring 2011 Introduction Photoacoustic imaging (PA Imaging) is the

More information

Absorption of an electromagnetic wave

Absorption of an electromagnetic wave In vivo optical imaging?? Absorption of an electromagnetic wave Tissue absorption spectrum Extinction = Absorption + Scattering Absorption of an electromagnetic wave Scattering of an electromagnetic wave

More information

Assays for gene expression and protein production

Assays for gene expression and protein production Assays for gene expression and protein production Module 3, Lecture 5! 20.109 Spring 2011! Topics for Lecture 5 Measuring protein levels! Measuring transcript levels! Imaging assays! 2 Module overview:

More information

Quantum Dots and Carbon Nanotubes in Cancer diagnose EE453 Project Report submitted by Makram Abd El Qader

Quantum Dots and Carbon Nanotubes in Cancer diagnose EE453 Project Report submitted by Makram Abd El Qader Quantum Dots and Carbon Nanotubes in Cancer diagnose EE453 Project Report submitted by Makram Abd El Qader abdelqad@unlv.nevada.edu, Fall 2008 Abstract On the basis of research and cancer medical treatment,

More information

Azure cseries. A new way to see the light. c600 c500 c400 c300 c200

Azure cseries. A new way to see the light. c600 c500 c400 c300 c200 Azure cseries A new way to see the light. c6 c5 c4 c3 c2 Infrared Laser Excitation for Quantitative Western Blot Imaging in the NIR Improve Your Data Quality Imaging with infrared dyes offers signal stability

More information

ZW800-1, Carboxylic Acid

ZW800-1, Carboxylic Acid ZW800-1, Carboxylic Acid Product Finder Information: Category I want to. Checkbox (Select One of the following choices) X Label an antibody, protein, or hydrophilic molecule Perform immunofluorescence

More information

Electronic Supplementary Information

Electronic Supplementary Information Electronic Supplementary Information Enzyme-Responsive Copper Sulphide Nanoparticles for Combined Photoacoustic Imaging, Tumor-Selective Chemotherapy and Photothermal Therapy Zhengbao Zha, b Shuhai Zhang,

More information

Wp6. Cancer Imaging with focus on breast cancer

Wp6. Cancer Imaging with focus on breast cancer Wp6. Cancer Imaging with focus on breast cancer Anikitos Garofalakis Frederic Joliot Hospital Service(SHFJ), Institute of Biomedical imaging(i g( 2 BM), Atomic Energy Commission(CEA) 1 background The use

More information

APPLICATIONS OLYMPUS ANTICANCER, INC. TECHNOLOGY PARTNERSHIP OV100 In vivo imaging system OV100 TM fluorescence imaging system for visualizing cancer cell extravasation in live mice Detailed dynamic changes

More information

OpenPlex. Multiplex Label-Free Interaction Analysis. Open Research Platform

OpenPlex. Multiplex Label-Free Interaction Analysis. Open Research Platform OpenPlex Multiplex Label-Free Interaction Analysis Open Research Platform OpenPlex Get information about: Kinetics Affinity Specificity Concentration Relative binding OpenPlex is the ideal solution for

More information

Enhanced Light Trapping in Periodic Aluminum Nanorod Arrays as Cavity Resonator

Enhanced Light Trapping in Periodic Aluminum Nanorod Arrays as Cavity Resonator Enhanced Light Trapping in Periodic Aluminum Nanorod Arrays as Cavity Resonator Rosure B. Abdulrahman, Arif S. Alagoz, Tansel Karabacak Department of Applied Science, University of Arkansas at Little Rock,

More information

Azure cseries. A new way to see the light. c600 c500 c400 c300

Azure cseries. A new way to see the light. c600 c500 c400 c300 Azure cseries A new way to see the light. c600 c500 c400 c300 Infrared Laser Excitation for Quantitative Western Blot Imaging in the NIR Improve Your Data Quality Imaging with infrared dyes offers signal

More information

Raman Spectroscopy Measurement System and Data Analysis for Characterization of Composite Overwrapped Pressure Vessels (COPVs)

Raman Spectroscopy Measurement System and Data Analysis for Characterization of Composite Overwrapped Pressure Vessels (COPVs) Raman Spectroscopy Measurement System and Data Analysis for Characterization of Composite Overwrapped Pressure Vessels (COPVs) Phillip A. Williams and Buzz Wincheski Nondestructive Evaluation Sciences

More information

Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice

Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice Sachin V. Patwardhan, Sharon R. Bloch, Samuel Achilefu, and Joseph P. Culver* Mallinckrodt Institute of Radiology, Department

More information

Supporting Information

Supporting Information Supporting Information Selective determination of Cr(VI) by glutaraldehyde crosslinked chitosan polymer fluorophores Jieyao Song a,b, Hongjian Zhou a,*, Rui Gao c, Yong Zhang a,b, Haimin Zhang a, Yunxia

More information

The ingenious Fusion Optics in the Spark multimode reader

The ingenious Fusion Optics in the Spark multimode reader The ingenious Fusion Optics in the Spark multimode reader Technical Note COMBINING FILTERS AND QUAD4 MONOCHROMATORS IN SPARKS STANDARD FLUORESCENCE MODULE FOR FLUORESCENCE APPLICATIONS 2 INTRODUCTION Multimode

More information

WHITE PAPER: Autofluorescence removal, multiplexing and automated analysis methods for in-vivo fluorescence imaging

WHITE PAPER: Autofluorescence removal, multiplexing and automated analysis methods for in-vivo fluorescence imaging WHITE PAPER: Autofluorescence removal, multiplexing and automated analysis JR Mansfield, KW Gossage, RM Levenson Abstract The ability to image and quantitate fluorescently labeled markers in vivo has generally

More information

Supplementary Information. Trojan Horse Nanotheranostics with Dual Transformability and Multifunctionality. for Highly Effective Cancer Treatment

Supplementary Information. Trojan Horse Nanotheranostics with Dual Transformability and Multifunctionality. for Highly Effective Cancer Treatment Supplementary Information Trojan Horse Nanotheranostics with Dual Transformability and Multifunctionality for Highly Effective Cancer Treatment Xue et. al. Supplementary Figure 1. Synthetic route of PhD

More information

AD (Leave blank) TITLE: A Novel Hand-Held Optical Imager with Real-Time Coregistration Facilities toward Diagnostic Mammography

AD (Leave blank) TITLE: A Novel Hand-Held Optical Imager with Real-Time Coregistration Facilities toward Diagnostic Mammography AD (Leave blank) Award Number: W81XWH-09-1-0004 TITLE: A Novel Hand-Held Optical Imager with Real-Time Coregistration Facilities toward Diagnostic Mammography PRINCIPAL INVESTIGATOR: Sarah Erickso CONTRACTING

More information

Cellular imaging using Nano- Materials. A Case-Study based approach Arun Murali, Srivats V

Cellular imaging using Nano- Materials. A Case-Study based approach Arun Murali, Srivats V Cellular imaging using Nano- Materials A Case-Study based approach Arun Murali, Srivats V Agenda Discuss a few papers Explain a couple of new imaging techniques and their benefits over conventional imaging

More information

Monitoring of High Power Laser Welding Process by Using Image Difference Algorithm

Monitoring of High Power Laser Welding Process by Using Image Difference Algorithm , October 24-26, 2012, San Francisco, USA Monitoring of High Power Laser Welding Process by Using Image Difference Algorithm Deyong You, Xiangdong Gao Abstract Process monitoring is important for the laser

More information

Fluorescence spectroscopy

Fluorescence spectroscopy Fluorescence spectroscopy The light: electromagnetic wave Zoltán Ujfalusi Biophysics seminar Dept. of Biophysics, University of Pécs 14-16 February 2011 Luminescence: light is not generated by high temperatures!!!

More information

Wide Dynamic Range Sensing in Photonic Crystal Microcavity. Biosensors

Wide Dynamic Range Sensing in Photonic Crystal Microcavity. Biosensors Wide Dynamic Range Sensing in Photonic Crystal Microcavity Biosensors Chun-Ju Yang 1 *, Hai Yan 1,Yi Zou 1, Swapnajit Chakravarty 2 *, Naimei Tang 2, Zheng Wang 1, Ray T. Chen 1, 2 * 1 Dept. Electrical

More information

Microscopy from Carl Zeiss

Microscopy from Carl Zeiss Microscopy from Carl Zeiss LSM 710 In Tune with Your Application Enjoy new freedom in selecting fluorescent dyes with In Tune, the new laser system for the LSM 710. Whatever the wavelength, you can match

More information

Single cell molecular profiling using Quantum Dots. Technical Journal Club Rahel Gerosa

Single cell molecular profiling using Quantum Dots. Technical Journal Club Rahel Gerosa Single cell molecular profiling using Quantum Dots Technical Journal Club 01.10.2013 Rahel Gerosa Molecular Profiling Powerful technique to study complex molecular networks underlying physiological and

More information

BME101 Introduction to Biomedical Engineering Medical Imaging Özlem BİRGÜL Ankara University Department of Biomedical Engineering

BME101 Introduction to Biomedical Engineering Medical Imaging Özlem BİRGÜL Ankara University Department of Biomedical Engineering BME101 Introduction to Biomedical Engineering Medical Imaging Özlem BİRGÜL Ankara University Department of Biomedical Engineering Outline What is Medical Imaging? History of Medical Imaging X-Ray Imaging

More information

FLUORESCENCE PROPERTIES OF QUANTUM DOTS

FLUORESCENCE PROPERTIES OF QUANTUM DOTS FLUORESCENCE PROPERTIES OF QUANTUM DOTS Šmerková K. 1, Blažková I. 1, Chudobová, D. 1, Vaculovičová M. 1, 2, Kopel P. 1, 2, Adam V. 1, 2,Kizek R. 1, 2 1 Department of Chemistry and Biochemistry, Faculty

More information

A New Continuous Wave 2500W Semiconductor Laser Vertical Stack

A New Continuous Wave 2500W Semiconductor Laser Vertical Stack A New Continuous Wave 2500W Semiconductor Laser Vertical Stack Xiaoning Li 1,2, Chenhui Peng 1, Yanxin Zhang 1, Jingwei Wang 1, Lingling Xiong 1, Pu Zhang 1, Xingsheng Liu 1,3 1 State Key Laboratory of

More information

Electronic Supporting Information

Electronic Supporting Information Electronic Supplementary Material (ESI) for RSC Advances. This journal is The Royal Society of Chemistry 2018 Electronic Supporting Information An Au@Ag Nanocube based Plasmonic Nano-sensor for Rapid Detection

More information

Sub-micron scale patterning of fluorescent. silver nanoclusters using low-power laser

Sub-micron scale patterning of fluorescent. silver nanoclusters using low-power laser Sub-micron scale patterning of fluorescent silver nanoclusters using low-power laser Puskal Kunwar 1,*, Jukka Hassinen 2, Godofredo Bautista 1, Robin H. A. Ras 2, and Juha Toivonen 1 1 Tampere University

More information