Start display at page:

Download "Amersham ECL Prime Western Blotting Detection Reagent"

Transcription

1 GE Healthcare Life Sciences Instructions AC Amersham Amersham ECL Prime Western Blotting Detection Reagent RPN 2232

2 Table of Contents Description Important user information Handling Components and other materials required How to improve the Western Blotting Quality control Protocol Additional information Troubleshooting guide Related products References Instructions AC

3 Description Amersham ECL Prime Western Blotting detection reagent from GE Healthcare provides an improved high sensitivity chemiluminescent method for the detection of immobilized specific antigens conjugated to Horseradish Peroxidase (HRP) labeled antibodies. Introduction The peroxide-catalyzed oxidation of Luminol generates weak chemiluminescence at 425 nm. With Amersham ECL Prime detection reagent, incorporation of a redox mediator, or enhancer, into the buffer will improve the enzyme turnover and increase the equilibrium concentration of Luminol radical anion. This will significantly improve the signal intensity and the signal duration (,2). Addition of a catalyst will improve the light signal further (3). The enhanced HRP catalyzed oxidation of Luminol is a complex, multi-step reaction: Instructions AC 3

4 Design and features Amersham ECL Prime detection reagent is designed to provide long signal duration (24 hours) and improved sensitivity (picogram levels). The high intensity light output means that antibodies can be diluted much further than when using other chemiluminescent substrates, see Determination of optimum antibody concentration, on page 22 for recommended dilutions, and makes detection optimal with a CCD camera, e.g LAS 4000 ImageQuant from GE Healthcare. The output light can also be detected using autoradiography film (Amersham Hyperfilm ECL). Membrane compatibility Amersham ECL Prime detection reagent is optimized for use with Amersham Hybond -P PVDF membrane where the performance compared to standard chemiluminescent substrates is most enhanced, but is also compatible with Amersham Hybond ECL nitrocellulose membrane. 4 Instructions AC

5 2 Important user information Intended use Amersham ECL Prime detection reagent is intended for the detection of immobilized specific antigens conjugated to Horseradish Peroxidase. Amersham ECL Prime detection reagent is intended for research use only, and shall not be used in any clinical procedures, or for diagnostic purposes. Safety notices This user documentation contains CAUTIONS concerning the safe use of Amersham ECL Prime detection reagent. See definitions below. Cautions CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. It is important not to proceed until all stated conditions are met and clearly understood. Instructions AC 5

6 3 Handling Safety precautions CAUTION Hazardous substances. When using hazardous chemicals, take all suitable protective measures, such as wearing protective glasses and gloves resistant to the substances used. Follow local and/or national regulations for safe operation. It is recommended to read the Materials Safety Data Sheet (MSDS) before using Amersham ECL Prime detection reagent. Storage On receipt, all components should be stored in a refrigerator at 2ºC to 8ºC. Amersham ECL Prime detection reagent is sensitive to prolonged exposure to light. Always store the individual reagents in the light-tight containers in which they are provided. Expiry The components are stable for at least 3 months when stored under the recommended conditions. See expiry date on package. 6 Instructions AC

7 4 Components and other materials required Kit components The following components are included in the Amersham ECL Prime detection reagent kit. Product RPN2232 Content Solution A: Luminol solution, 50 ml. Solution B: Peroxide solution, 50 ml. Sufficient for 000 cm 2 membrane Solutions Required solutions and the chemical reagents needed for these solutions are listed below. Solution Phosphate buffered saline (PBS), ph 7.5 Tris buffered saline (TBS), ph 7.6 Diluent and wash buffer PBS Tween (PBS-T) and TBS Tween (TBS-T) Preparations Prepare.5 g Di-sodium Hydrogen Orthophosphate Anhydrous (80 mm), 2.96 g Sodium Dihydrogen Orthophosphate (20 mm), 5.84 g Sodium Chloride (00 mm). 2 Dilute to 000 ml with distilled water. 3 Check ph. Prepare 8 g Sodium Chloride, 20 ml M Tris HCl, ph Dilute to 000 ml with distilled water. 3 Check ph. Dilute the required amount of Tween 20 in the corresponding buffer. 0.% Tween 20 concentration is suitable for most blotting applications. Instructions AC 7

8 Storage of buffers All buffers should be stable for at least 3 months if prepared in advance and stored at room temperature, although storage in a refrigerator may be necessary to avoid microbial spoilage. Do not use sodium azide as a bacteriocide. Completed Western blot membrane Use a suitable protocol to separate proteins by electrophoresis and transfer them to a PVDF or nitrocellulose membrane. Blocking reagents Blocking reagents are typically diluted to 2% to 5% (v/v) in PBS or TBS buffer. The following blocking reagents are recommended: Amersham ECL Prime Blocking Agent (RPN48) Amersham ECL Blocking Agent (RPN225) Non-fat dry milk Bovine Serum Albumine (BSA) Immunodetection reagents Primary antibody specific to the target protein(s) HRP conjugated secondary antibody that specifically binds to the primary antibody. See Amersham ECL HRP-linked Secondary Antibodies, on page 3. Dilute the antibodies according to the recommendations in Dilution ranges, on page Instructions AC

9 5 How to improve the Western Blotting Introduction To achieve an optimal western blotting result with high signal to noise ratio and best possible sensitivity and linearity, it is important to optimize the method and to select compatible products. Consider the following to get the most out of your experiment: Sample quality and loading amount It is important that the sample is of good quality and that the amount of target protein is in detectable levels. Membrane and blocking Select membrane and blocking agent compatible with sample and antibodies. Primary and secondary antibodies Always select specific antibodies of high quality and invest some time to optimize the antibody dilution. Detection and imaging Select detection reagent according to your application need. A CCD imager offers high sensitivity and broad dynamic range and provide better quantification than X-ray film. This chapter describes products recommended for use with Amersham ECL Prime detection reagent and all other Amersham ECL Western Blotting Systems from GE Healthcare. For more information regarding these products, refer to Instructions AC 9

10 Amersham Rainbow markers Amersham Rainbow Markers are good for confirming transfer and orientation (as the colored bands transfer to the membrane) as well as determination of molecular weight. Amersham Rainbow Markers, available as full-range (M r to , ten proteins), high-range (M r to , eight proteins), and low-range (M r to ). Rainbow Markers are suitable for Amersham ECL and Amersham ECL Prime. Amersham ECL DualVue Markers, optimized for use with Amersham ECL and Amersham ECL Prime, are the optimal positive controls for Western Blotting. The colored bands, which are visible both on the gel and on the membrane after transfer, serve to indicate the progress of the electrophoresis, confirm protein transfer to the membrane, and help the user orientate the blot. In addition, the bands are also detected with the chemiluminescent substrates, appearing on the film or digital image and thus serve as a control for the detection system. Amersham membranes Amersham Hybond-P is a PVDF membrane suitable for all chemiluminescent Western blotting kits. It is a robust and durable membrane suitable for stripping and re-probing and is optimal for use with Amersham ECL Prime detection reagent. Amersham Hybond-ECL is a nitrocellulose membrane compatible with all chemiluminescent Western blotting substrates. 0 Instructions AC

11 Transfer Wet transfer (Transfer Unit TE 62), the most commonly used transfer method, is especially efficient for large proteins. Semi-dry transfer (Transfer Units TE 70 and TE 77), is faster than wet transfer and consumes less buffer. Semi-dry transfer works well for most proteins but transfer may be less efficient for large proteins. It also reduces sensitivity for very low abundance proteins. Blocking agents Unwanted binding and the resulting background caused by the primary antibody can be minimized by choosing the best blocking agent. Compatibility of the blocking agent with the detection system is important as it will affect background. The following blocking agents are recommended: Amersham ECL Prime Blocking Agent Amersham ECL Membrane Blocking Agent BSA Blocking Agent Non-fat dry milk Instructions AC

12 Imagers and film The ImageQuant imager range, including ImageQuant LAS 4000 and ImageQuant LAS 4000 mini, are flexible systems that cover a wide range of imaging applications including quantitative imaging of Amersham ECL, Amersham ECL Prime, Amersham ECL Plex and gel documentation. These CCD based imagers provide an affordable option for protein detection with genuine benefits, including better quantitation than film without sacrificing sensitivity, publication grade data, and image and data archiving. Amersham Hyperfilm ECL is a trusted product for reliable qualitative chemiluminescent detection in Western blots. Amersham Western Blotting website The Western Blotting website gathers years of expertise of experimental design in one place, with a user forum supported by GE scientists and engineers. For technical help, tips, and best practices in quantitative protein detection, visit 2 Instructions AC

13 6 Quality control The Amersham ECL Prime detection reagent is manufactured in compliance with our ISO 900 certified quality management system, and is in conformity with the acceptance criteria set up for the product. Instructions AC 3

14 7 Protocol Protocol overview Below is an overview of the Western Blotting detection protocol. Gel electrophoresis Transfer Blocking agent Primary antibody Secondary antibody Detection reagent Detection 4 Instructions AC

15 Electrophoresis and transfer protocol Step Action Notes Perform electrophoresis and transfer according to standard protocols. Proteins should be transferred to Amersham Hybond-P for optimum results. Amersham Hybond ECL membranes can also be used. Blots may be used immediately or stored in a desiccator at 2 C to 8 C for up to 3 months. Amersham Hybond-P should be pre-wetted in 00% methanol, washed in distilled water for 5 minutes and equilibrated in transfer buffer for at least 0 minutes before transfer. Amersham Hybond ECL should be prewetted in distilled water and equilibrated in transfer buffer for at least 0 minutes before transfer. Blocking the membrane protocol Step Action Notes 2 3 Block non-specific binding sites by immersing the membrane in a suitable blocking solution, see Blocking reagents, on page 8). Incubate for hour at room temperature on an orbital shaker. Alternatively, membranes may be left in the blocking solution overnight in a refrigerator at 2 C to 8 C, if more convenient. Briefly rinse the membrane with two changes of wash buffer (see Solutions, on page 7). The combination of non-fat dried milk and Tween should be sufficient for most applications. Optimum Tween concentrations will vary to suit specific experiments, but a 0.% Tween 20 concentration is suitable for most blotting While washing, prepare the diluted primary antibody (step, Primary antibody incubation protocol, on page 6). Instructions AC 5

16 Primary antibody incubation protocol Step Action Notes Dilute the primary antibody in PBS-T or TBS-T. The dilution factor should be optimized for each antibody. Optimization of the antibody dilution can be performed by dot blot analysis (see Determination of optimum antibody concentration, on page 22). Due to the high signal intensity, primary and secondary antibodies might need further dilution when detecting with film, compared to CCD detection, to avoid saturated signals. 2 3 Incubate the membrane in diluted primary antibody for hour at room temperature on an orbital shaker or over night 2 C to 8 C. Briefly rinse the membrane with two changes of wash buffer. Wash the membrane by suspending it in wash buffer and agitate for 5 minutes in room temperature. Replace wash buffer at least 4 to 6 times. Incubation times and temperatures may vary and should be optimized for each antibody. The conditions indicated are recommended starting points. While washing prepare the diluted secondary antibody (step, Secondary antibody incubation protocol, on page 6.). Secondary antibody incubation protocol Step Action Notes Dilute the HRP labeled secondary antibody or biotinylated antibody in PBS-T or TBS-T. The dilution factor should be optimized for each antibody (Determination of optimum antibody concentration, on page 22). Use either an appropriate HRP labeled secondary antibody or a biotinylated secondary antibody and the HRP labeled streptavidin bridge system. 6 Instructions AC

17 Step 2 3 Action Incubate the membrane in the diluted secondary antibody for hour at room temperature on an orbital shaker. Briefly rinse the membrane with two changes of wash buffer. Notes Incubation times and temperatures may vary and should be optimized for each antibody. The conditions indicated are recommended starting points. 4 Wash the membrane by suspending it in enough wash buffer to cover the membrane and agitate for 5 minutes at room temperature. Replace wash buffer at least 4 to 6 times. If using an HRP labeled secondary antibody proceed directly to Detection protocol, on page 8 after this wash procedure. If using a biotinylated antibody, while washing, prepare the diluted streptavidin HRP conjugate or complex (Streptavidin bridge incubation protocol, on page 7). Streptavidin bridge incubation protocol Step If using an HRP labeled secondary antibody, proceed directly to Detection protocol, on page 8. Action Notes 2 3 Dilute the Streptavidin HRP conjugate or Streptavidinbiotinylated HRP complex in PBS-T or TBS-T. Incubate the membrane in the dilution for 45 to 60 minutes at room temperature on an orbital shaker. Briefly rinse the membrane with two changes of wash buffer. The dilution factor should be optimized (Determination of optimum antibody concentration, on page 22). Instructions AC 7

18 Step 4 Action Wash the membrane by suspending it in enough wash buffer to cover the membrane and agitate for 5 minutes at room temperature. Replace wash buffer at least 4 to 6 times. Notes Detection protocol Step Two detection protocols are described in this section, one for CCD camera which is optimal with Amersham ECL Prime detection reagent and another one for using autoradiography film. CCD camera protocol Action Notes Allow the detection solutions to equilibrate to room temperature before opening. Mix detection solutions A and B in a ratio of : to a working solution. The final volume of detection reagent required is 0. ml/cm 2 membrane. Drain the excess wash buffer from the washed membranes and place protein side up on a sheet of plastic wrap or other suitable clean surface. Add the mixed detection reagent on to the membrane. Incubate for 5 minutes at room temperature. If the mixed reagent is not to be used immediately protect it from exposure to the light either by wrapping in foil or storing in a dark place. The reagents should cover the entire surface of the membrane, held by surface tension on to the surface of the membrane. 8 Instructions AC

19 Step 5 6 Action Drain off excess detection reagent by holding the membrane gently in forceps and touching the edge against a tissue. Place the blots, protein side up on a sample tray. Notes The blots can be placed on a piece of plastic wrap, protein side up, to facilitate easy movement of the film on the sample tray. 7 Place the sample tray in the CCD camera compartment. Operate the camera according to the User documentation included with the camera. Expose the membrane for 60 seconds. Exposure time can be optimized to achieve optimal results. Recommended starting exposure time is 60 seconds. Instructions AC 9

20 Step Autoradiography film protocol Action Notes Same as step -4 in the CCD camera protocol above. Drain off excess detection reagent by holding the membrane gently in forceps and touching the edge against a tissue. Place the blots protein side down on to a fresh piece of plastic wrap, wrap up the blots and gently smooth out any air bubbles. Place the wrapped blots, protein side up, in an x-ray film cassette. Place a sheet of autoradiography film (for example, Amersham Hyperfilm ECL) on top of the membrane. Close the cassette and expose for 5 seconds. Remove the film and replace with a second sheet of unexposed film. Develop the first piece of film immediately, and on the basis of its appearance estimate how long to continue the exposure of the second piece of film. Second exposures can vary from minute to hour. Ensure there is no free detection reagent in the cassette; the film must not get wet. This stage should be carried out in a dark room using red safe lights. Do not move the film while it is being exposed. 20 Instructions AC

21 8 Additional information Stripping and reprobing membranes Step The complete removal of primary and secondary antibodies from the membrane is possible following the protocol outlined below. The membranes may be stripped of bound antibodies and reprobed several times. Membranes should be stored wet wrapped in plastic wrap in a refrigerator (2 to 8 C) after each immunodetection. Action Notes Submerge the membrane in stripping buffer (00 mm 2-Mercaptoethanol, 2% SDS, 62.5 mm Tris-HCl ph 6.7 ) and incubate at 50 C for 30 minutes with occasional agitation. Wash the membrane for 2 x 0 minutes in PBS-T or TBS-T at room temperature using large volumes of wash buffer. Block the membrane in suitable blocking solution for hour at room temperature. Repeat the immunodetection protocol in Chapter 7, stages from Primary antibody incubation protocol to Detection protocol. If more stringent conditions are required the incubation can be performed at 70 C or incubate for a longer time. Membranes may be incubated with Amersham ECL Prime detection reagent and exposed to film to ensure removal of antibodies. Instructions AC 2

22 Determination of optimum antibody concentration Due to the improved sensitivity of the Amersham ECL Prime detection reagent, optimization of antibody concentrations is recommended to ensure the best results. In general, lower concentrations of both primary and secondary antibodies are required with Amersham ECL Prime detection reagent compared to standard chemiluminescent substrates, especially when using PVDF membranes. Outlined below are protocols for determining optimal antibody concentrations. Dilution ranges The following dilution ranges are recommended: Antibody Primary Secondary Primary antibodies Dilution range from mg/ml stock solution :000 - :50000 : : Dot blots are a quick and effective method of determining the optimum dilution of a primary antibody of unknown concentration. Alternatively, a Western blot can be prepared and then cut into several strips. It should be noted that some antibodies may require alternative blocking and washing steps to the ones suggested below. Step Action 2 3 Spot a suitable amount of protein sample on to a PVDF or nitrocellulose membrane and allow to air dry. Prepare one blot for each primary antibody dilution to be tested. Incubate in blocking solution for hour at room temperature with agitation. Rinse the membranes briefly with two changes of wash buffer. 22 Instructions AC

23 Step Action Prepare a number of solutions within the recommended antibody dilution range. Incubate blot in each dilution for hour at room temperature with agitation. Briefly rinse the membrane with two changes of wash buffer. Wash the membrane by suspending it in wash buffer and agitate for 5 minutes in room temperature. Replace wash buffer at least 4 to 6 times. Dilute the secondary antibody (using only one concentration) and incubate the membranes for hour at room temperature with agitation. Rinse blots in two changes of wash buffer, then wash for x 5 minutes and 3 x 5 minutes in fresh changes of wash buffer. Detect using Amersham ECL Prime detection reagent detailed in Detection protocol, on page 8. of the protocol. The antibody dilution which gives the best signal with the minimum background should be selected. Secondary antibodies Step Action Spot a suitable amount of protein sample on to a PVDF or nitrocellulose membrane and allow to air dry. Prepare one blot for each primary antibody dilution to be tested. Incubate in blocking solution for hour at room temperature with agitation. Incubate in diluted primary antibody for hour at room temperature with agitation. Briefly rinse the membrane with two changes of wash buffer. Wash the membrane by suspending it in wash buffer and agitate for 5 minutes in room temperature. Replace wash buffer at least 4 to 6 times. Instructions AC 23

24 Step Action Prepare a number of solutions within the recommended antibody dilution range. Incubate blot in each dilution for hour at room temperature with agitation. Briefly rinse the membrane with two changes of wash buffer. Wash the membrane by suspending it in wash buffer and agitate for 5 minutes in room temperature. Replace wash buffer at least 4 to 6 times. Detect using Amersham ECL Prime detection reagent detailed in Detection protocol, on page 8 of the protocol. The antibody dilution which gives the best signal with minimum background should be selected. 24 Instructions AC

25 9 Troubleshooting guide Problems No signal Weak signal Possible causes / remedies Incorrect species of secondary antibody has been used. PVDF membrane not pre-wetted in methanol. Check that transfer equipment is working properly and that the correct procedure has been followed. Check protein transfer by staining the gel and/or membrane. Confirm transfer efficiency by using pre-stained Rainbow marker. Some antigens may be affected by the treatments required for electrophoresis. Target protein degradation may occur if the blots are stored incorrectly. Detection reagents may have become contaminated. - To test the detection reagent activity, in a darkroom prepare to 2 ml of detection reagent working solution in a clear test tube. Add µl of undiluted HRP-conjugated antibody solution. The solution should immediately emit a visible blue light that fades during the next severals minutes. Incorrect storage of Amersham ECL Prime detection reagent may cause a loss of signal. Bad quality and/or unspecific primary antibody. Transfer efficiency may have been poor. Insufficient protein was loaded on to the gel. The concentration of primary and secondary antibodies could be too low; optimization is required. Bad quality and/or unspecific primary antibody. Exposure time may have been too short. Instructions AC 25

26 Problems Excessive, diffuse signal White (negative) bands on the film Uneven, spotted background Possible causes / remedies Too much protein was loaded on to the gel. Electrophoresis and transfer protocols may need optimization. The concentrations of primary and secondary antibodies could be too high; optimization is required. Negative bands generally occur when protein target is in excess and antibody concentrations are too high. The effect is caused by substrate depletion. Blotting technique requires optimization. Areas of the blot may have dried during some of the incubations. Incorrect handling can lead to contamination on the blots and/or membrane damage which may cause non-specific signal. The blocking agent is not completely dissolved in the buffer. 26 Instructions AC

27 Problems High backgrounds Possible causes / remedies The concentrations of primary and secondary antibodies could be too high; optimization is required. Contamination can be transferred to the blots from electrophoresis and related equipment used in blot preparation. Transfer and incubation buffers may have become contaminated and require replacing. Insufficient blocking. The blocking agent used was not freshly prepared or was too dilute or was incompatible with the application. The level of Tween used in the blocking agent was not sufficient for the application performed. The membrane was allowed to dry during some of the incubations. Poor gel quality. Unspecific and bad quality of antibodies. Insufficient washing. - The washes were not performed for a sufficient period of time or were nor performed in a high enough volume. - There was insufficient Tween in the washes. - Insufficient changes of washes were used. The film detection of the signal was allowed to over expose. The level of signal is so high that the film has become completely overloaded. Non compatible products. Instructions AC 27

28 0 Related products This chapter presents a subset of related products. For more information, refer to Sample preparation Product Mammalian Protein Extraction Buffer Yeast Protein Extraction Buffer Kit 2-D Quant Kit Quantity (for 500 ml) 500 assays Code no Vivaspin sample concentrators with molecular weight cut off (MWCO) Vivaspin 500 Vivaspin 2 Vivaspin 6 Vivaspin x 500 μl 25 x 2 ml 25 x 6 ml 2 x 20 ml MWCO (3000, 5000, 0000, and 00000) are available for all Vivaspin volumes. Amersham markers Product Low-Range Rainbow Molecular Weight Markers High-Range Rainbow Molecular Weight Markers Full-Range Rainbow Molecular Weight Markers Amersham ECL DualVue Western Blotting Markers Amersham ECL Plex Fluorescent Rainbow Markers Amersham ECL Plex Fluorescent Rainbow Markers Amersham ECL Western Blotting Molecular Weight Markers Quantity 250 μl 250 μl 250 μl pack (25 loadings) 20 μl 500 μl pack (25 loadings) Code no. RPN755E RPN756E RPN800E RPN80 RPN850E RPN85E RPN Instructions AC

29 Gel electrophoresis equipment Product Electrophoresis Systems minive Vertical Electrophoresis System minive Blot Module SE 260 Mini-Vertical Unit for two slab gels SE 600 Ruby Standard Dual Cooled Vertical Unit Power Supplies EPS 30 Power Supply EPS 2A20 Power Supply Quantity Code no Transfer equipment Product Amersham ECL Semidry Blotters Quantity Code no. TE 70 Semi-Dry Transfer Unit, 4 x 6 cm TE 70 PWR Semi-Dry Transfer Unit, 4 x 6 cm TE 77 Semi-Dry Transfer Unit, 2 x 26 cm TE 77 PWR Semi-Dry Transfer Unit, 2 x 26 cm TE 62 Transfer Cooled Unit Blotting equipment Amersham ECL Multiprobe Amersham ECL Multiprobe XL Including Power Supply Instructions AC 29

30 Blotting membranes Product Amersham blotting membranes Hybond ECL (20 x 20 cm) Hybond-C Extra (20 x 20 cm) Hybond-P (20 x 20 cm) Hybond-LFP (20 x 20 cm) Hybond Blotting Paper (20 x 20 cm) Whatman blotting membranes Protran BA85, 0.45 μm pore size 20 x 20 cm Protran BA83, 0.2 μm pore size 20 x 20 cm Protran BA79, 0. μm pore size 20 x 20 cm Optitran BA-S 85, 0.45 μm pore size 20 x 20 cm Optitran BA-S 83, 0.2 μm pore size 20 x 20 cm Whatman blotting papers 3MM Chr 20 x 20 cm Quantity 0 sheets 0 sheets 0 sheets 0 sheets 00 sheets 25 sheets 25 sheets 25 sheets 25 sheets 25 sheets 00 sheets Code no. RPN2020D RPN2020E RPN2020F RPN2020LFP RPN60M Amersham Blocking agents Product ECL Prime Blocking Agent ECL Blocking Agent Quantity 40 g Code no. RPN48 RPN Instructions AC

31 Amersham ECL HRP-linked Secondary Antibodies Product ECL Mouse IgG, HRP-Linked Whole Ab (from sheep) ECL Mouse IgG, HRP-Linked Whole Ab (from sheep) ECL Human IgG, HRP-Linked Whole Ab (from sheep) ECL Rabbit IgG, HRP-Linked Whole Ab (from donkey) ECL Rabbit IgG, HRP-Linked Whole Ab (from donkey) ECL Rat IgG, HRP-Linked Whole Antibody (from goat) ECL Mouse IgG, HRP-Linked F(ab ) 2 Fragment (from sheep) ECL Rabbit IgG, HRP-Linked F(ab ) 2 Fragment (from donkey) ECL Rat IgG, HRP-Linked F(ab ) 2 Fragment (from goat) Quantity 00 μl ml ml 00 μl ml ml ml ml ml Code no. NA93-00UL NA93-ML NA933-ML NA934-00UL NA934-ML NA935 NA930-ML NA9340-ML NA9350 Kits and Reagent Packs Product Amersham ECL Western Blotting Detection Reagents for 4000 cm 2 membrane Amersham ECL Western Blotting System Amersham ECL Western Blotting Detection Reagents for 000 cm 2 membrane Amersham ECL Western Blotting Detection Reagents for 6000 cm 2 membrane Quantity kit Code no. RPN206 RPN208 RPN209 RPN234 Instructions AC 3

32 Product Amersham ECL Prime Western Blotting Detection Reagents for 000 cm 2 membrane Quantity Code no. RPN2232 Amersham ECL Plex CyDye conjugated Antibodies Product Amersham ECL Plex Western Blotting Combination Pack (Cy3, Cy5, Hybond ECL) Amersham ECL Plex Western Blotting Combination Pack (Cy3, Cy5, Hybond LFP) for two slab gels Quantity Code no. RPN998 RPN999 Autoradiography Films Product Amersham Hyperfilm ECL (5 x 7 inches) Amersham Hyperfilm ECL (8 x 24 cm) Amersham Hyperfilm ECL (8 x 0 inches) Amersham Hyperfilm ECL (24 x 30 cm) Amersham Hyperfilm ECL (35 x 43 cm) Quantity 50 sheets 50 sheets 50 sheets 50 sheets 50 sheets Code no Imaging Systems Product ImageQuant LAS 4000 ImageQuant LAS 400 ImageQuant LAS 4000 mini Quantity Code no Instructions AC

33 Software and Accessories Product CD and getting started: ImageQuant TL 7.0 and IQTL SecurITy 8.0 Software package (with Getting Started Guide) Licenses for ImageQuant TL only: ImageQuant TL, single user license Quantity Licenses for ImageQuant TL v7.0 and IQTL SecurITy v8.0: ImageQuant TL 7.0 and ImageQuant TL SecurITy 8.0 -user Code no Instructions AC 33

34 References No. 2 3 Reference Kricka, L.J., Methods Enzymol. 305, , (2000). Heindl, D. and Josel, H.P. Non-radioactive Analysis of Biomolecules, , (997). Marzocci, E., Grilli. S., Della Ciana, L., Prodi, L., Roda, A. and Mirasoli, M., Anal. Biochem., 377, 89-94, (2008). 34 Instructions AC

35

36 For local office contact information, visit GE Healthcare Bio-Sciences AB Björkgatan Uppsala Sweden GE, imagination at work and GE monogram are trademarks of General Electric Company. Amersham, ECL, ECL DualVue, ECL Plex, Hybond, Hyperfilm, ImageQuant, Optitran, Protran, Rainbow, and Whatman are trademarks of GE Healthcare companies. This product or portions thereof is manufactured and sold under license from Cyanagen Srl and is subject of US patent number , US patent application number and Italian application number TO200A000580, together with other equivalent granted patents and patent applications in other countries. All third party trademarks are the property of their respective owners General Electric Company All rights reserved. First published Sep. 200 All goods and services are sold subject to the terms and conditions of sale of the company within GE Healthcare which supplies them. A copy of these terms and conditions is available on request. Contact your local GE Healthcare representative for the most current information. GE Healthcare Europe GmbH Munzinger Strasse 5, D-79 Freiburg, Germany GE Healthcare UK Limited Amersham Place, Little Chalfont, Buckinghamshire, HP7 9NA, UK GE Healthcare Bio-Sciences Corp. 800 Centennial Avenue, P.O. Box 327, Piscataway, NJ , USA GE Healthcare Japan Corporation Sanken Bldg.3-25-, Hyakunincho Shinjuku-ku, Tokyo , Japan imagination at work AC 04/20

Amersham ECL start Western Blotting Detection Reagent

Amersham ECL start Western Blotting Detection Reagent Amersham ECL start Western Blotting Detection Reagent Product booklet Code: RPN3243 RPN3244 RPN3245 Page Finder 1. Legal 4 2. Description 5 2.1 Introduction 5 2.2 Design and features 6 2.3 Compatibility

More information

Amersham ECL Advance Western Blotting Detection Kit

Amersham ECL Advance Western Blotting Detection Kit GE Healthcare Life Sciences Amersham ECL Advance Western Blotting Detection Kit Product Booklet Code: RPN2135 Page finder 1. Legal 3 2. Handling 4 2.1. Safety warnings and precautions 4 2.2. Storage 4

More information

Amersham GST Western Blotting Detection Kit

Amersham GST Western Blotting Detection Kit GE Healthcare Amersham GST Western Blotting Detection Kit For the detection of GST fusion proteins on Western Blots using enhanced chemiluminescence Product Booklet Code: RPN1237 Page finder 1. Legal 3

More information

LumiGOLD ECL Western Blotting Detection Kit

LumiGOLD ECL Western Blotting Detection Kit LumiGOLD ECL Western Blotting Detection Kit An Enhanced Chemiluminescence Western Blotting Detection Kit for HRP Cat. No.: SL100309-L Store at: 4 C for 18 months Kit Contents Cat. No.: SL100309-L, Reagent

More information

Introduction. Important Product Information. Number Description. Table of Contents

Introduction. Important Product Information. Number Description. Table of Contents Super Signal Western ECL Substrate Number Description Super Signal Western ECL Substrate, Sufficient for 1000cm2 of membrane Kit Contents: Super Signal Western Solution A, 50mL Super Signal Western Solution

More information

Amersham Western blotting

Amersham Western blotting Amersham Western blotting Selection guide www.gelifesciences.com Innovative solutions designed to meet your specific protein analysis needs Since 1990 when we first launched Amersham ECL we have continued

More information

Amersham Hybond and Amersham Protran Membranes

Amersham Hybond and Amersham Protran Membranes Amersham Hybond and Amersham Protran Membranes Optimized for protein transfer Product Booklet Page Finder 1. Legal 4 2. Handling 6 2.1 Safety warnings and precautions 6 2.2 Storage 6 2.3 Stability 6 2.4

More information

Amersham * ECL * Gel horizontal electrophoresis system

Amersham * ECL * Gel horizontal electrophoresis system GE Healthcare Life Sciences Data file 28-9970-20 AB Electrophoresis products Amersham * ECL * Gel horizontal electrophoresis system Amersham ECL Gel and Amersham ECL Gel Box constitute a horizontal mini-gel

More information

Optiblot ECL Ultra Detect Kit (1.2pg 2ng)

Optiblot ECL Ultra Detect Kit (1.2pg 2ng) ab133409 Optiblot ECL Ultra Detect Kit (1.2pg 2ng) Instructions for Use For enhanced chemiluminescent Western blotting. This product is for research use only and is not intended for diagnostic use. 1 Table

More information

Western BLoT Ultra Sensitive HRP Substrate

Western BLoT Ultra Sensitive HRP Substrate Cat. # T7104A For Research Use Western BLoT Ultra Sensitive Product Manual Table of Contents I. Description... 3 II. Components... 3 III. Storage... 3 IV. Materials Required but Not Provided... 3 V. Precautions...

More information

Albumin & IgG Depletion SpinTrap

Albumin & IgG Depletion SpinTrap GE Healthcare Albumin & IgG Depletion SpinTrap Albumin & IgG Depletion SpinTrap is designed for depletion of albumin and IgG from human plasma or serum. Product booklet Code: 28-9480-20 Page finder 1.

More information

IR-Blot Secondary antibodies Rev00

IR-Blot Secondary antibodies Rev00 0 About us Cyanagen is a biotech company located in Bologna, dedicated to research, development and production of reagents for molecular diagnostic since 2003 and one of the leading companies in the field

More information

EZ-ECL Chemiluminescence Detection Kit for HRP

EZ-ECL Chemiluminescence Detection Kit for HRP BIOLOGICAL INDUSTRIES India Contact: Life Technologies (India) Pvt. Ltd. 306, Aggarwal City Mall, Opposite M2K Pitampura, Delhi 110034 (INDIA). Ph: +91-11-42208000, 42208111, 42208222 Mobile: +91-9810521400

More information

SERVALight EosUltra Western Blot Chemiluminescence HRP Substrate Kit

SERVALight EosUltra Western Blot Chemiluminescence HRP Substrate Kit INSTRUCTION MANUAL SERVALight EosUltra Western Blot Chemiluminescence HRP Substrate Kit (Cat. No. 42586) SERVA Electrophoresis GmbH Carl-Benz-Str. 7 D-69115 Heidelberg Phone +49-6221-138400, Fax +49-6221-1384010

More information

Western BLoT Quant HRP Substrate

Western BLoT Quant HRP Substrate For Research Use Western BLoT Quant Product Manual Table of Contents I. Description... 3 II. Components... 3 III. Storage... 3 IV. Materials Required but Not Provided... 4 V. Precautions... 5 VI. Protocol...

More information

IR-Blot Secondary antibodies Rev01

IR-Blot Secondary antibodies Rev01 0 About us Cyanagen is a biotech company located in Bologna, dedicated to research, development and production of reagents for molecular diagnostic since 2003 and one of the leading companies in the field

More information

Western BLoT Quant HRP Substrate

Western BLoT Quant HRP Substrate For Research Use Western BLoT Quant Product Manual Table of Contents I. Description... 3 II. Components... 3 III. Storage... 3 IV. Materials Required but Not Provided... 4 V. Precautions... 5 VI. Protocol...

More information

Amersham Western blotting

Amersham Western blotting Amersham Western blotting Selection guide gelifesciences.com Innovative solutions for your Western blotting Since 1990 when we first launched Amersham ECL, we have continued our commitment to providing

More information

Radiance. Long Protocol for Catalog Numbers. Chemiluminescent substrate for quantitative chemiluminescent Westerns

Radiance. Long Protocol for Catalog Numbers. Chemiluminescent substrate for quantitative chemiluminescent Westerns Radiance Chemiluminescent substrate for quantitative chemiluminescent Westerns Long Protocol for Catalog Numbers AC2100 Radiance Sample, sufficient for 140 cm 2 membrane AC2101 Radiance, 150 ml, sufficient

More information

Western BLoT Hyper HRP Substrate

Western BLoT Hyper HRP Substrate For Research Use Western BLoT Hyper Product Manual Table of Contents I. Description... 3 II. Components... 3 III. Storage... 3 IV. Materials Required but Not Provided... 4 V. Precautions... 5 VI. Protocol...

More information

Radiance Plus. Long Protocol for Catalog Numbers. Chemiluminescent substrate for the most sensitive Western blotting experiments

Radiance Plus. Long Protocol for Catalog Numbers. Chemiluminescent substrate for the most sensitive Western blotting experiments Radiance Plus Chemiluminescent substrate for the most sensitive Western blotting experiments Long Protocol for Catalog Numbers AC2102 Radiance Plus Sample, sufficient for 200 cm 2 membrane AC2103 Radiance

More information

Optiblot ECL Detect Kit (23 pg 187 ng)

Optiblot ECL Detect Kit (23 pg 187 ng) ab133406 Optiblot ECL Detect Kit (23 pg 187 ng) Instructions for Use For enhanced chemiluminescent Western blotting. This product is for research use only and is not intended for diagnostic use. 1 Table

More information

WesternBright Quantum

WesternBright Quantum User Manual WesternBright Quantum Chemiluminescent HRP Substrate For Catalog Numbers K-12042-C20 20 ml, sufficient for 200 cm 2 K-12042-D10 100 ml, sufficient for 1000 cm 2 K-12042-D20 200 ml, sufficient

More information

WesternBright TM Quantum

WesternBright TM Quantum User Manual WesternBright TM Quantum Chemiluminescent HRP Substrate For Catalog Numbers K-12042-C20 20 ml, sufficient for 200 cm 2 K-12042-D10 100 ml, sufficient for 1000 cm 2 K-12042-D20 200 ml, sufficient

More information

WesternBright TM ECL. For Catalog Numbers. User Manual. Chemiluminescent HRP Substrate

WesternBright TM ECL. For Catalog Numbers. User Manual. Chemiluminescent HRP Substrate User Manual WesternBright TM ECL Chemiluminescent HRP Substrate For Catalog Numbers K-12045-C20 20 ml, sufficient for 200 cm 2 K-12045-D20 200 ml, sufficient for 2000 cm 2 K-12045-D50 500 ml, sufficient

More information

KPL SignaLOCK ChemiWestern Kits (Film and Imager Analysis)

KPL SignaLOCK ChemiWestern Kits (Film and Imager Analysis) KPL SignaLOCK ChemiWestern Kits (Film and Imager Analysis) SignaLOCK HRP ChemiWestern Kit (Film) Catalog No. 54-53-00 SignaLOCK HRP ChemiWestern Kit (Imager) Catalog No. 54-54-00 SignaLOCK AP ChemiWestern

More information

Western BLoT Chemiluminescence HRP Substrate

Western BLoT Chemiluminescence HRP Substrate Cat. # T7101A For Research Use Western BLoT Chemiluminescence Product Manual Table of Contents I. Description... 3 II. Components... 3 III. Storage... 3 IV. Materials Required but Not Provided... 4 V.

More information

Orexin A (HUMAN, MOUSE, RAT, PORCINE, OVINE,

Orexin A (HUMAN, MOUSE, RAT, PORCINE, OVINE, Orexin A (HUMAN, MOUSE, RAT, PORCINE, OVINE, BOVINE) Western Blot Kit Protocol (Catalog #WBK-003-30) PHOENIX PHARMACEUTICALS, INC. TABLE OF CONTENTS 1. Kit Contents...2 2. Storage...2 3. Introduction...3

More information

WANT TO IMPROVE YOUR WESTERN BLOTTING EFFICIENCY? TAKE ADVANTAGE OF OUR GREAT WORKFLOW OFFERS!

WANT TO IMPROVE YOUR WESTERN BLOTTING EFFICIENCY? TAKE ADVANTAGE OF OUR GREAT WORKFLOW OFFERS! WANT TO IMPROVE YOUR WESTERN BLOTTING EFFICIENCY? TAKE ADVANTAGE OF OUR GREAT WORKFLOW ERS! Western blotting workflow GREAT ERS! Although the details of Western blotting protocols may vary from application

More information

LumiPico ECL Kit. ShineGene. User Manual. For Western Blot. Cat.Nos.ZK00901(12.5ml 2) ZK00902(50.0ml 2) LumiPico ECL Kits User Manual

LumiPico ECL Kit. ShineGene. User Manual. For Western Blot. Cat.Nos.ZK00901(12.5ml 2) ZK00902(50.0ml 2) LumiPico ECL Kits User Manual LumiPico ECL Kits User Manual ShineGene LumiPico ECL Kit For Western Blot User Manual Cat.Nos.ZK00901(12.5ml 2) ZK00902(50.0ml 2) USD44.46 USD175.20 Published 24 Feb 2007 ShineGene LumiPico ECL Kits User

More information

ProSignal Dura Juniper Creek Lane, San Diego, CA Phone: Fax:

ProSignal Dura Juniper Creek Lane, San Diego, CA Phone: Fax: ProSignal Dura 8430 Juniper Creek Lane, San Diego, CA 92126 Phone: 800.789.5550 Fax: 888.789.0444 Email: support@geneseesci.com www.geneseesci.com User Manual ProSignal Dura Chemiluminescent HRP Substrate

More information

Streptavidin Mag Sepharose

Streptavidin Mag Sepharose GE Healthcare Life Sciences Data file 28-9921-05 AB Protein sample preparation Streptavidin Mag Sepharose Streptavidin Mag Sepharose (Fig 1) is a magnetic bead for simple and efficient enrichment of target

More information

Amersham ECL Plex Western blotting system Products listed below are optimized for use with Amersham ECL Plex Western Blotting System

Amersham ECL Plex Western blotting system Products listed below are optimized for use with Amersham ECL Plex Western Blotting System Amersham ECL Plex Western blotting system Products listed below are optimized for use with Amersham ECL Plex Western Blotting System Product booklet Product ranges and codes: Amersham ECL Plex CyDye conjugated

More information

ProSignal Pico Juniper Creek Lane, San Diego, CA Phone: Fax:

ProSignal Pico Juniper Creek Lane, San Diego, CA Phone: Fax: ProSignal Pico 8430 Juniper Creek Lane, San Diego, CA 92126 Phone: 800.789.5550 Fax: 888.789.0444 Email: support@geneseesci.com www.geneseesci.com User Manual ProSignal Pico Chemiluminescent HRP Substrate

More information

Sensido Advance ECL Substrate (HRP) Solution A (Substrate Solution) Solution B (Peroxide Solution)

Sensido Advance ECL Substrate (HRP) Solution A (Substrate Solution) Solution B (Peroxide Solution) Sensido Advance ECL Substrate (HRP) ADD: 7F, 72, Song-Te Rd., Taipei 110, Taiwan TEL : 886-2-2723-0886 www.recenttec.com Order Info Cat. Components Volume Package R13-VG016-100 Solution A (Substrate Solution)

More information

Technical Data Sheet. Sensido Plus ECL Substrate (HRP) Description. Advantages

Technical Data Sheet. Sensido Plus ECL Substrate (HRP) Description. Advantages ECL Substrate (HRP) Catalog R13-VG08 Technical Data Sheet ADD: 7F, 72, Song-Te Rd., Taipei 110, Taiwan TEL : 886-2-2723-0886 www.recenttec.com Package Cat. Components Solution A (Substrate Solution) Solution

More information

SuperSignal West Pico Chemiluminescent Substrate

SuperSignal West Pico Chemiluminescent Substrate INSTRUCTIONS SuperSignal West Pico Chemiluminescent Substrate 3747 N. Meridian Road P.O. Box 117 Rockford, IL 61105 34077 34078 34079 34080 0636.3 Number Description 34079 SuperSignal West Pico Chemiluminescent

More information

KPL LumiGLO Reserve Chemiluminescent Substrate

KPL LumiGLO Reserve Chemiluminescent Substrate DESCRIPTION KPL LumiGLO Reserve contains a luminol-based chemiluminescent substrate designed for use with peroxidase-labeled (HRP) reporter molecules. KPL LumiGLO Reserve offers improvements in the way

More information

Instruction AB

Instruction AB GE Healthcare Life Sciences Instruction 28-9242-34 AB Biacore Biotin CAPture Kit Product description Order code: Contents: Storage: Kit capacity: 28-9202-33 (Biotin CAPture Kit) 28-9202-34 (Biotin CAPture

More information

VisiGlo and VisiGlo Plus

VisiGlo and VisiGlo Plus VisiGlo and VisiGlo Plus Code Description Size N218-KIT N218-S-KIT N218-SAMPLE-KIT N219-KIT VisiGlo HRP Chemiluminscent Substrate Kit VisiGlo HRP Chemiluminscent Substrate Kit VisiGlo HRP Chemiluminscent

More information

Easy-WESTERN-II Super

Easy-WESTERN-II Super Easy-WESTERN-II Super Primary Antibody Detection Reagent for Western Blots User Manual for High Sensitivity and Strong Signal Detection Immediately after receiving the kit, read the section titled COMPONENTS

More information

2. Handling Expiry The components of these products are stable for at least 6 months when stored under the recommended conditions.

2. Handling Expiry The components of these products are stable for at least 6 months when stored under the recommended conditions. GE Healthcare Albumin and IgG Removal kit Ettan sample preparation kits and reagents. An affinity resin for specific removal of albumin and IgG from human serum. A complete set of consumables required

More information

Cheluminate-HRP PicoDetect

Cheluminate-HRP PicoDetect Cheluminate-HRP PicoDetect Enhanced ChemiLuminescence Detection Kit for Western / Southern / Northern Blotting Product-No. A3417 Description The CheLuminate-HRP PicoDetect is a complete kit with ready-to-use

More information

KPL LumiGLO Ultra Western Blotting Substrate

KPL LumiGLO Ultra Western Blotting Substrate DESCRIPTION KPL LumiGLO Ultra contains an acridane-based chemiluminescent substrate designed for use with peroxidase-labeled (HRP) reporter molecules. KPL LumiGLO Ultra offers several improvements over

More information

Amersham ECL Western blotting detection reagents

Amersham ECL Western blotting detection reagents Amersham ECL Western blotting detection reagents Selection guide gelifesciences.com Choose the ECL Western blotting detection reagent that best suits your needs Enhanced chemiluminescent (ECL) detection

More information

Ab SpinTrap Ab Buffer Kit

Ab SpinTrap Ab Buffer Kit GE Healthcare Data File 28-9020-30 AB Protein Sample Preparation Ab SpinTrap Ab Buffer Kit The Ab SpinTrap and the Protein G HP SpinTrap are identical columns. The difference between the article numbers

More information

LumiBlue ECL Extreme Enhanced chemiluminescent substrate for Western Blot amplification success

LumiBlue ECL Extreme Enhanced chemiluminescent substrate for Western Blot amplification success Enhanced chemiluminescent substrate for Western Blot amplification success INDEX Ordering information... 3 Kit contents and required materials... 3 Storage and Expiry... 4 Introduction... 4 Protocol...

More information

LumiBlue ECL Extended Enhanced chemiluminescent substrate for Western Blot amplification success

LumiBlue ECL Extended Enhanced chemiluminescent substrate for Western Blot amplification success Enhanced chemiluminescent substrate for Western Blot amplification success INDEX Ordering information... 3 Kit contents and required materials... 3 Storage and Expiry... 4 Introduction... 4 Protocol...

More information

LumiBlue ECL Pico Enhanced chemiluminescent substrate for Western Blot amplification success

LumiBlue ECL Pico Enhanced chemiluminescent substrate for Western Blot amplification success Enhanced chemiluminescent substrate for Western Blot amplification success INDEX Ordering information... 3 Kit contents and required materials... 3 Storage and Expiry... 4 Introduction... 4 Protocol...

More information

Easy-WESTERN-II Super

Easy-WESTERN-II Super Easy-WESTERN-II Super Primary Antibody Detection Reagent for Western Blots User Manual for High Sensitivity and Strong Signal Detection Immediately after receiving the kit, read the section titled COMPONENTS

More information

Western Blot Tool Box

Western Blot Tool Box Western Blot Tool Box BOX12/BOX12-03 V1.1 Store at 2-8 C For research use only Introduction The Western Blot Tool Box is designed to conveniently provide reagents/buffers needed for Western blotting, from

More information

His Buffer Kit is intended for research use only, and should not be used in any clinical or in vitro procedures for diagnostic purposes.

His Buffer Kit is intended for research use only, and should not be used in any clinical or in vitro procedures for diagnostic purposes. GE Healthcare Instructions 28-4010-39 AC His Buffer Kit Intended use His Buffer Kit is intended for research use only, and should not be used in any clinical or in vitro procedures for diagnostic purposes.

More information

2-D Fractionation Kit

2-D Fractionation Kit GE Healthcare 2-D Fractionation Kit Ettan sample preparation kits and reagents. Product Booklet Code: 80-6501-04 Page finder 1. Legal 3 2. Handling 4 2.1. Safety warnings and precautions 4 2.2. Storage

More information

Sera-Mag SpeedBeads Magnetic Protein A/G Particles

Sera-Mag SpeedBeads Magnetic Protein A/G Particles Procedure 29-1079-14 AA Protein enrichment Sera-Mag SpeedBeads Magnetic Protein A/G Particles Sera-Mag SpeedBeads Protein A/G Magnetic Particles (Table 1) provide a fast and convenient method for both

More information

Amersham ECL glycoprotein detection system

Amersham ECL glycoprotein detection system GE Healthcare Amersham ECL glycoprotein detection system Sufficient for 50 solution labellings or 25 8 x 10 cm membrane labellings Product Booklet Codes: RPN2190 RPN2191 Page finder 1. Legal 3 2. Handling

More information

Chemiluminescence Detection System for Horseradish Peroxidase. (Cat. # , , , , T)

Chemiluminescence Detection System for Horseradish Peroxidase. (Cat. # , , , , T) 123PR-02 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name femtolucent PLUS-HRP Chemiluminescence Detection System for Horseradish Peroxidase

More information

Western BLoT Immuno Booster

Western BLoT Immuno Booster Cat. # T7111A For Research Use Western BLoT Product Manual Table of Contents I. Description... 3 II. Components... 3 III. Storage... 3 IV. Materials Required but Not Provided... 3 V. Precautions... 3 VI.

More information

ab Optiblot Fluorescent Western Blot Kit

ab Optiblot Fluorescent Western Blot Kit ab133410 Optiblot Fluorescent Western Blot Kit Instructions for Use For quantitative, multi-color fluorescent Western blotting. This product is for research use only and is not intended for diagnostic

More information

rprotein A GraviTrap Protein G GraviTrap rprotein A/Protein G GraviTrap

rprotein A GraviTrap Protein G GraviTrap rprotein A/Protein G GraviTrap GE Healthcare Life Sciences Data file 28-9921-04 AA rprotein A GraviTrap Protein G GraviTrap rprotein A/Protein G GraviTrap Protein sample preparation rprotein A GraviTrap, Protein G GraviTrap, and rprotein

More information

Immun-Star WesternC Chemiluminescent Kit

Immun-Star WesternC Chemiluminescent Kit Immun-Star WesternC Chemiluminescent Kit Instruction Manual For Use With Nitrocellulose and PVDF Membranes Catalog # 170-5070 For technical support, call your local Bio-Rad office, or in the US, call 1-800-4BIORAD

More information

Regeneration Scouting Kit

Regeneration Scouting Kit GE Healthcare Life Sciences Instruction 22-0618-29 AC Biacore Regeneration Scouting Kit Product description Order code: Contents: Storage: Safety: BR-1005-56 Ethylene glycol (p.a.), 11 ml Glycine-HCl,

More information

Amersham QuickStain. GE Healthcare. Electrophoresis reagents

Amersham QuickStain. GE Healthcare. Electrophoresis reagents GE Healthcare Electrophoresis reagents Amersham QuickStain The Amersham QuickStain Kit contains a Cy 5 fluorophore and labeling buffer for easy detection of proteins in SDS- PAGE gels and on Western blotting

More information

ONE-HOUR Western TM Multiplex Kit II

ONE-HOUR Western TM Multiplex Kit II ONE-HOUR Western TM Multiplex Kit II Technical Manual No. 0256 Version 06192009 I Description... 1 II Kit Contents.. 2 III Related Products 2 IV Key Features. 2 V Storage... 2 VI ONE-HOUR Multiplex Western

More information

IgG TrueBlot Protocol for Mouse, Rabbit or Goatderived Antibodies - For Research Use Only

IgG TrueBlot Protocol for Mouse, Rabbit or Goatderived Antibodies - For Research Use Only IgG TrueBlot Protocol for Mouse, Rabbit or Goatderived Antibodies - For Research Use Only Introduction The IgG TrueBlot for mouse, rabbit, or goat-derived antibodies represents unique series of respective

More information

Gel filtration using ÄKTA start

Gel filtration using ÄKTA start GE Healthcare Life Sciences Gel filtration using ÄKTA start Training cue card This protocol will help you understand the practical principles of gel filtration by taking you step-by-step through the purification

More information

Sample preparation for analysis of proteins, peptides and carbohydrates

Sample preparation for analysis of proteins, peptides and carbohydrates GE Healthcare Life Sciences Sample preparation for analysis of proteins, peptides and carbohydrates Desalting, Buffer Exchange, Cleanup, Concentration Selection guide The Trap platform The Trap platform

More information

Protein A HP SpinTrap

Protein A HP SpinTrap GE Healthcare Instructions 28-9067-70 AB Protein A HP SpinTrap Protein A HP SpinTrap contains 16 prepacked Protein A HP SpinTrap columns 1 plastic bottom cap removal tool Instructions for use Introduction

More information

WesternMAX Alkaline Phosphatase Chemiluminescent Detection Kits

WesternMAX Alkaline Phosphatase Chemiluminescent Detection Kits WesternMAX Alkaline Phosphatase Chemiluminescent Detection Kits Code N221-KIT N220-KIT Description WesternMAX Chemiluminescent AP Kit, Anti-Mouse Includes: Alkaline Phosphatase (AP) Conjugated Anti-Mouse

More information

Protein A Mag Sepharose Xtra Protein G Mag Sepharose Xtra

Protein A Mag Sepharose Xtra Protein G Mag Sepharose Xtra GE Healthcare Instructions 28-9670-57 AA Mag Sepharose Protein A Mag Sepharose Xtra Protein G Mag Sepharose Xtra Protein A Mag Sepharose Xtra and Protein G Mag Sepharose Xtra are available in the following

More information

Easy-WESTERN-II Quick

Easy-WESTERN-II Quick Easy-WESTERN-II Quick Primary Antibody Detection Reagent for Western Blots User Manual for Quick Antigen Detection or Multi Antigen Detection Immediately after receiving the kit, read the section titled

More information

GE Healthcare. Processor Plus. Protocol Guide for Western Blotting

GE Healthcare. Processor Plus. Protocol Guide for Western Blotting GE Healthcare Processor Plus Protocol Guide for Western Blotting Important user information All users must read this entire manual to fully understand the safe use of Processor Plus. Important! Processor

More information

His Mag Sepharose excel

His Mag Sepharose excel GE Healthcare Life Sciences Instructions 29-0163-14 AC Protein sample preparation His Mag Sepharose excel His Mag Sepharose excel is a magnetic immobilized metal ion affinity chromatography (IMAC) medium

More information

2. Phos Binding Reagent Biotin (PBR-B) Protocol

2. Phos Binding Reagent Biotin (PBR-B) Protocol 2. Phos Binding Reagent Biotin (PBR-B) 1 Solutions for PBR-B Method Tris buffered saline Sol. A: Tris buffered saline (10xTBS, 1 L, ph 7.5) Tris (0.10 mol/l) ------------------------------------------------------

More information

His Tag Western and LumiBlot Reagents Sensitive detection of His Tag fusion proteins

His Tag Western and LumiBlot Reagents Sensitive detection of His Tag fusion proteins His Tag Western and LumiBlot Reagents Sensitive detection of His Tag fusion proteins The His Tag Reagents are kits containing optimized components for blot detection using the His Tag Monoclonal Antibody.

More information

Streptavidin HP SpinTrap Streptavidin HP MultiTrap Streptavidin HP SpinTrap Buffer Kit

Streptavidin HP SpinTrap Streptavidin HP MultiTrap Streptavidin HP SpinTrap Buffer Kit GE Healthcare Data File 28-9067-91 AB Protein Sample Preparation Streptavidin HP SpinTrap Streptavidin HP MultiTrap Streptavidin HP SpinTrap Buffer Kit Streptavidin HP SpinTrap and Streptavidin HP MultiTrap

More information

Protein A Mag Sepharose Xtra Protein G Mag Sepharose Xtra

Protein A Mag Sepharose Xtra Protein G Mag Sepharose Xtra GE Healthcare Data file 28-9768-1 AA Protein sample preparation Protein A Mag Sepharose Xtra Xtra products are magnetic beads designed for efficient, high capacity small-scale purification/screening of

More information

GE Healthcare. GammaBind G Sepharose

GE Healthcare. GammaBind G Sepharose GE Healthcare Instructions 71-7057-00 AH Affinity Media GammaBind G Sepharose GammaBind G Sepharose is GammaBind G, Type 2, covalently immobilized to Sepharose 4B by the cyanogen bromide method. GammaBind

More information

Chemiluminescent Substrates

Chemiluminescent Substrates s Cost comparisons between various s Table 6. Blotting cost comparison between SuperSignal, GE Healthcare's ECL and Western Lightning Products. SuperSignal GE Healthcare (APB) Western West Pico ECL Lightning

More information

ONE-HOUR Complete IP-Western Kit

ONE-HOUR Complete IP-Western Kit ONE-HOUR Complete IP-Western Kit Technical Manual No. 0218 Version 06192009 I Description.. 1 II Kit Contents.. 2 III Related Products 2 IV Key Features.. 2 V Storage.. 2 VI ONE-HOUR Western Protocol 3

More information

In-Gel Western Detection Using Near-Infrared Fluorescence

In-Gel Western Detection Using Near-Infrared Fluorescence In-Gel Western Detection Using Near-Infrared Fluorescence Developed for: Aerius, and Odyssey Family of Imagers Please refer to your manual to confirm that this protocol is appropriate for the applications

More information

Western Blot Protocol

Western Blot Protocol Western Blot Protocol Western blotting (WB) is the most widely performed immunoassay and is the best initial validation technique used to identify proteins of interest within a tissue homogenate or cell

More information

Convenient Purification of Monoclonal Antibodies using HiTrap rprotein A FF

Convenient Purification of Monoclonal Antibodies using HiTrap rprotein A FF GE Healthcare Convenient Purification of Monoclonal Antibodies using HiTrap rprotein A FF M. Carlsson, A. Heijbel, and A-C. Häggqvist GE Healthcare AB, Björkgatan 3, SE-751 84 Uppsala, Sweden Abstract

More information

Protein A HP MultiTrap

Protein A HP MultiTrap GE Healthcare Instructions 28-9067-71 AC Protein A HP MultiTrap Protein A HP MultiTrap contains 4 prepacked Protein A HP MultiTrap 96-well filter plates Instructions for use Introduction Protein A HP MultiTrap

More information

Western Blot Analysis

Western Blot Analysis Odyssey Infrared Imaging System Western Blot Analysis Published October, 2004. The most recent version of this protocol is posted at http://biosupport.licor.com/support Doc# 988-07737 Odyssey Western Blot

More information

Multiplex Fluorescent Western Blot Starter Kit for the Bio- Rad ChemiDoc MP

Multiplex Fluorescent Western Blot Starter Kit for the Bio- Rad ChemiDoc MP Page 1 of 7 INSTRUCTIONS: Z-310 Multiplex Fluorescent Western Blot Starter Kit for the Bio- Rad ChemiDoc MP Rockland Immunochemicals and Bio-Rad Laboratories have jointly developed an easy to use multiplex

More information

PRODUCT INFORMATION & MANUAL

PRODUCT INFORMATION & MANUAL PRODUCT INFORMATION & MANUAL PicoTect TM Western Blot Chemiluminescent Substrate NBP2-29912 Sufficient for 10 mini-blots (800 cm2 of membrane) For research use only. Not fodiagnostic or therapeutic procedures.

More information

Amersham Rediprime II DNA Labeling System

Amersham Rediprime II DNA Labeling System GE Healthcare Amersham Rediprime II DNA Labeling System Product Booklet Codes: RPN1633 RPN1634 Page finder 1. Legal 3 2. Handling 4 2.1. Safety warnings and precautions 4 2.2. Storage 4 2.3. Expiry 4 3.

More information

Azure Biosystems Western Blotting Workflow

Azure Biosystems Western Blotting Workflow Azure Biosystems Western Blotting Workflow PROBE PLAN SEPARATE ANALYZE VISUALIZE PLAN Plan your experiment and choose your detection method Chemiluminescent Western Blotting The most common method for

More information

Affinity purification using ÄKTA start

Affinity purification using ÄKTA start GE Healthcare Life Sciences Affinity purification using ÄKTA start Training cue card This protocol will help you understand the practical principles of affinity chromatography by taking you step-by-step

More information

Protein A HP SpinTrap

Protein A HP SpinTrap GE Healthcare Protein A HP SpinTrap Product booklet Code: 28-9031-32 Page finder 1. Legal 3 2. Handling 4 2.1. Safety warnings and precautions 4 2.2. Storage 4 2.3 Expiry 4 3. Introduction 5 4. General

More information

Protein G HP SpinTrap / Ab Spin Trap

Protein G HP SpinTrap / Ab Spin Trap GE Healthcare Life Sciences Protein G HP SpinTrap / Ab Spin Trap Product booklet Codes: 28-9031-34 28-4083-47 Page finder 1. Legal 3 2. Handling 4 2.1. Safety warnings and precautions 4 2.2. Storage 4

More information

Strep-tag detection in Western blots

Strep-tag detection in Western blots Strep-tag detection in Western blots General protocol for the detection of Strep-tag fusion proteins Last date of revision April 2012 Version PR07-0010 www.strep-tag.com For research use only Important

More information

Table of Contents. Catalog No

Table of Contents. Catalog No Table of Contents Catalog No. 54-11-50 Section Page Introduction 2 Materials and Equipment 3 Warnings and Precautions 4 Protocols Western Blotting Protocol At A Glance 5 PAGE and Western Blotting 6-7 Detection

More information

One-Step Western TM Kit using TMB

One-Step Western TM Kit using TMB Technical Manual No. 0203 Version 03272008 I Description.. 1 II Kit Contents.. 2 III Applications 3 IV Key Features.. 3 V Storage.. 3 VI One-Step Western TM Protocol. 3 VII Examples. 3 VIII Troubleshooting..

More information

Amersham ECL Gel System Compatibility Guide

Amersham ECL Gel System Compatibility Guide GE Healthcare Life Sciences Amersham ECL Gel System Compatibility Guide This guide provides useful hints and tips on how to use Amersham ECL Gel system for SDS-PAGE. It contains illustrative examples of

More information

STR amplification of DNA from buccal and blood samples stored long-term on Whatman FTA cards

STR amplification of DNA from buccal and blood samples stored long-term on Whatman FTA cards GE Healthcare Life Sciences Application note 29-0082-33 AA STR amplification of DNA from buccal and blood samples stored long-term on Whatman FTA cards FTA technology In this study we successfully amplified

More information

STR amplification of DNA from buccal and blood samples stored long-term on Whatman FTA cards

STR amplification of DNA from buccal and blood samples stored long-term on Whatman FTA cards GE Healthcare Life Sciences Application note 29-0082-33AA STR amplification of DNA from buccal and blood samples stored long-term on Whatman FTA cards FTA technology In this study we successfully amplified

More information

2 5 ADP Sepharose 4B. GE Healthcare Life Sciences

2 5 ADP Sepharose 4B. GE Healthcare Life Sciences GE Healthcare Life Sciences Instructions 71-7092-00 AF Affinity chromatography 2 5 ADP Sepharose 4B 2 5 ADP Sepharose 4B interacts strongly with NADP + -dependent dehydrogenases. Selective elution with

More information