CQA Assessment by Peptide Mapping Using LC/MS with an AdvanceBio Peptide Plus Column

Size: px
Start display at page:

Download "CQA Assessment by Peptide Mapping Using LC/MS with an AdvanceBio Peptide Plus Column"

Transcription

1 CQA Assessment by Peptide Mapping Using LC/MS with an AdvanceBio Peptide Plus Column Anne Blackwell, Ph.D. BioColumns Product Support Scientist June 7, 27 ASMS

2 Analytical groups are tasked with method development, sample analysis, and method transfer DNA Vector Establishment of genetically engineered cells (e.g. CHO) that produce desired product Biomarker ID & validation Samples Human gene HT Clone mab Generation Platform Screening & Cell Culture Scale-up & Production e.g. transgenic mice Selection Samples Samples Samples QA/QC Methods Analytical Groups Develop analytical methods; analyze samples from other functions, methods transfer Centrifuge Samples Samples Market Manufacturing Clinical Pre-clinical Chromatography Column #3 Chromatography Column #2 Chromatography Column # 2

3 Critical Quality Attributes & Testing Methods Not just used for monoclonal antibodies same techniques are used for any potentially therapeutic protein RP Disulfide Shuffling SEC Aggregation Pyro- Glutamate IEC LC/MS Intact mass Fragment mass Identification PTM ID & locations Glycan ID Glycosylation (G, G, G2) HILIC Fragmentation (Hinge) Truncation (Lys,, 2) IEC RP Deamidation /Oxidation IEC 3

4 B A(3-6) ( B(67-73) ) B(33-337) B(278-29) Peptide Mapping Workflow Solutions to Accelerate Biomolecule Characterization Data Acquisition Peptide mapping chromatogram Peptide ID by MS/MS Sequence Matching Determine Post Translational Modifications Chromatographic Separation Reporting Sample Preparation Complete Agilent Workflow Solution Delivery of Results 4

5 Sample Preparation for Peptide Mapping A time consuming, labor-intensive process to do manually, with multiple steps that can be optimized. Sample Preparation Depletion of matrix proteins, enrichment of target protein, dialysis or desalting Reduce disulfide bonds, and block to prevent re-formation Denaturation, Reduction, & Alkylation Digestion Trypsin is the most common digestion enzyme, but others may be called for depending on the protein and experiment. Sample concentration, enrichment for specific PTMs, or desalting Enrichment & Cleanup 5

6 AssayMAP Bravo Sample Prep Automation Peptide mapping Detect 6

7 AssayMAP Sample Prep Portfolio Antibody Purification Immunoaffinity Purification Fractionation Protein Digestion Peptide Clean Up Protein Clean Up Phosphopeptide Enrichment N-glycan Sample Prep 7

8 General Considerations for Peptide Mapping Column Selection Instrument capabilities and requirements - UV vs MS detection or both - Pressure capabilities Mobile phase requirements - High ph required for sample - TFA vs Formic acid Sample - Hydrophilic vs hydrophobic peptides - Larger polypeptides present Column dimensions - Generally prefer longer columns, especially for more complicated maps - 5, 5, and 25 mm lengths available - Use 2. mm i.d. for MS-sensitivity - 3. and 4.6 mm i.d. also available - Smaller pore sizes ideal, usually -5 Å 8

9 Detectors for Peptide Mapping UV Often used in routine process measurements, QA/QC labs No peptide mass or structural information; relies on reproducibility of RT, peak area, and peak area ratios Traditionally uses TFA modifier MS Often used in discovery/early development stage, R&D labs MW and structural information (MS/MS) to assist with co-elution challenges, verify sequence coverage, and to ID unknown peaks when they appear Generally prefer formic acid modifier to avoid ion suppression from TFA 9

10 Mobile Phases for Peptide Mapping Ion pairing agents used for RP LC Increase retention of small, poorly retained peptides Block exposed silanol sites on silica-based columns Acid helps solubilize and ionize peptide and protein samples TFA works well on traditional silicabased columns, but formic acid does not Formic acid produces broad, asymmetric peaks Poor resolution and poor peak capacity Need column solution for formic acid modifier AdvanceBio Peptide Plus Charged surface chemistry solves the problems associated with formic acid

11 Agilent Bio-LC Column Portfolio Agilent Bio-LC Columns Affinity Reversed Phase HILIC Size Exclusion Ion Exchange Bio-Monolith Protein A AdvanceBio Peptide Plus AdvanceBio Glycan Mapping AdvanceBio SEC Bio mab Bio-Monolith Protein G Multiple Affinity Removal System AdvanceBio Peptide Mapping AdvanceBio RP mab AdvanceBio Oligonucleotides AdvanceBio Desalting-RP ZORBAX RRHD 3-HILIC Bio SEC-3 Bio SEC-5 ProSEC 3S ZORBAX GF-25 Bio IEX (SAX, SCX, WAX, WCX) PL SAX PL SCX Bio-Monolith (QA, DEAE, SO 3 ) PLRP-S ZORBAX GF-45 ZORBAX RRHD 3Å,.8 µm AdvanceBio Amino Acid Analysis ZORBAX Amino Acid Analysis ZORBAX 3SB Poroshell 3

12 Agilent Bio-LC Column Portfolio Agilent Bio-LC Reverse Phase Columns for Protein Analysis Intact Proteins (& Fragments) Peptides Amino Acids PLRP-S, 5 µm, Å AdvanceBio Peptide Plus AdvanceBio Amino Acid Analysis AdvanceBio RP mab AdvanceBio Peptide Mapping ZORBAX Amino Acid Analysis ZORBAX RRHD.8 µm, 3 Å ZORBAX Eclipse Plus C8 ZORBAX 3SB ZORBAX 3SB* Poroshell 3 AdvanceBio Desalting-RP *unusually large pore size for peptide mapping, but some people really like it nonetheless 2

13 AdvanceBio Peptide Plus Poroshell particle UHPLC performance at lower pressure Unique charge hybrid/c8 bonded phase Improved peak shape and peak capacity for peptide analysis with formic acid and MS detection To provide AdvanceBio Peptide Plus that gives benefits in accuracy and reproducibility of results for characterization of mab identity, PTMs 3

14 Columns Individually Tested for Efficiency AdvanceBio Peptide Plus Column 4

15 Column Lots QA Tested Specifically for Peptide Separations Peptides Standard (p/n G ) AdvanceBio Peptide Plus Column 5

16 LC/MS Instrumentation 29 Infinity II LC system 6545XT AdvanceBio LC/Q-TOF BioConfirm B.8 for intact protein and peptide mapping data analysis 6

17 6545XT Features for Peptide Mapping Sensitive peptide detection featuring Agilent Jet Stream Quick-start peptide mapping method Access low intensity peptides/ptms with the new IterativeMS/MS mode Sub-ppm mass accuracy with 5k resolution from improved beam optics Peptide fragmentation performance verification at install Ease of maintenance with vent-free capillary removal

18 Method Conditions Parameter 29 Infinity II LC Column AdvanceBio Peptide Plus 2. 5mm, 2.7µm, 2Å Mobile phase A:.%FA B:.% FA in ACN Time (min) %B 3 3 Gradient Post time min Inj vol µl Sample thermostat 5 C Post time 5 min Column temp 55 C Flow rate.5 ml/min All results shown are with formic acid mobile phase Parameter 6545XT AdvanceBio LC/Q-TOF Ion mode Positive ion mode, dual AJS ESI (profile) Drying gas temp 325 C Drying gas flow 3 L/min Sheath gas temp 275 C Sheath gas flow 2 L/min Nebulizer Capillary voltage Fragmentor voltage Skimmer voltage Oct RF Vpp Acquisition parameters 35 psi 4 V 75 V 65 V 75 V Data were acquired at 2 GHz Extended Dynamic Range MS mass range 7 m/z MS/MS mass range 5 7 MS scan rate (spectra/second): 8 MS/MS scan rate (spectra/second): 3 Ramped collision energy Charge state Slope Offset and > Data analysis BioConfirm software B.8.8 8

19 Effect of Flow Rate on Peak Capacity AdvanceBio Peptide Plus Column x x 8. ml/min Increasing the flow rate from. ml/min to.5 ml/min leads to an increase of twice the peak capacity.5.2 ml/min x ml/min x 8.4 ml/min.5 x ml/min x ml/min TIC Counts vs. Acquisition Time (min) 9

20 Effect of Gradient Length on Peak Capacity AdvanceBio Peptide Plus Column x x 8 min Increasing the gradient time from min to 6 min leads to an increase 2.5 times peak capacity, After 3min, no significant increase in peak capacity.5 2 min x min.4 x min.4 x min.4 x min.4 TIC Counts vs. Acquisition Time (min) 2

21 Effect of Temperature on Peak Capacity AdvanceBio Peptide Plus Column Higher temperature produces narrower peaks, improving resolution Change in temperature changes selectivity ~2% more peaks resolved by increasing the column temperature to 55 C x o C Pc = 54 x o C Pc = 6 LC/MS Chromatogram Co unts vs. Acquisition Time (min) 2

22 Good Peak Shape & Retention Time Stability with High Mass Load AdvanceBio Peptide Peptide Plus Plus Competitor.6 ug 6 ug AdvanceBio Peptide Mapping.6 ug 6 ug Sample: 3-peptide mixture in.%fa Bradykinin Angiotensin II Venin substrate Competitor Cortecs 2 Competitor Kinetc 3.6 ug 6 ug.6 ug 6 ug Key for transferring methods between LC/MS and LC/UV All 2. x 5 mm columns 22

23 Co unts Highly Reproducible Separations x Hydrophilic Hydrophobic AdvanceBio Peptide Plus Column Acquisition Time (min) n = %RSD Peak no. RT FWHM Area Height Consistent chromatography RSD values demonstrate the robustness of the method and precision of the LC system Especially crucial for LC/UV peptide mapping 23

24 % Plate count Lifetime Testing Retention time % Column: AdvanceBio Peptide Plus Sample: peptide standard (59-583) Injection: 3 µl Flow rate:.5 ml/min Mobile phase: A.%FA B.% FA in ACN R t dropped < % Plates count % The column has subjected to injections and lost no more than % of the initial plate and retention value at the end of the test Plates dropped < % Good chemical stability under formic acid conditions 24

25 FWHM Better Column Options for Alternate Selectivity x AdvanceBio Peptide Mapping Peptide Standard (p/n ) x AdvanceBio Peptide Plus Counts vs. Acquisition Time (min).4.2 AdvBio Peptide Mapping AdvBio Peptide Plus TIC. Bradykinin frag Bradykinin 3. Angiotensin II (human) 4. Neurotensin 5. Angiotensin I (human) 6. Renin substrate porcine 7. [Ace-F-3,-2 H-] Angiotensinogen (-4) 8. Ser/Thr Protein Phosphatase (5-3) 9. [F4] Ser/Thr Protein Phosphatase (5-3). Melittin (honey bee venom) Peptide peak 25

26 Counts mab Peptide Mapping x 8 5 Hydrophilic LC/MS of mab tryptic digest on 2. x 5mm AdvanceBio Peptide Plus Column Hydrophobic Acquisition Time (min) Hydrophilic peptide retention Narrow Peaks with baseline resolution Hydrophobic peptide elution Reduced and fast analysis time Critical and desired peptide mapping components to achieve fast, selective, and highly efficient peptide separations across a wide dynamic range. 26

27 LC/MS Peptide Map AdvanceBio Peptide Plus Column sequence coverage 99.25% mass accuracy of 5 ppm 27

28 BioConfirm for Peptide Mapping AdvanceBio Peptide Plus Column Chromatograms MS spectrum MS/MS fragment spectrum Sequence map Biomolecules list b and y ion list 28

29 Identification of C-terminal Truncation SLSLSPG SLSLSPGK 29

30 Analysis of Post-Translational Modifications Post-translational modifications (PTMs) on proteins such as monoclonal antibodies (mab) are critical quality attributes (CQA) that define drug efficacy and safety PTM containing peptides represent the minority of the tryptic mixture and often masked by more dominant peptide signals Low stoichiometry & heterogeneity of many post-translational modifications make characterization of modification sites challenging Advantage of high mass load tolerance of AdvanceBio Peptide Plus Comprehensive characterization of PTMs requires: Separation of native and modified peptides (Column) Sensitive detection (Mass Spectrometry) Robust LC/MS method 3

31 Counts Separation of Oxidized Peptides 5 x DLTMISR peptide Unmodified peptide x x DLTMISR Unmodified peptide L,I T R y b y y 2-NH b -H2O b y y y Counts v s. M ass-to-charge (m/z) DLTMISR Oxidized peptide AdvanceBio Peptide Plus Column MS/MS spectra b 4-H2O y Oxidized peptide L,I y y b y b -H2O Acquisition Time (min) y -NH b -H2O EIC Relative % of Oxidation =.69% Counts vs. Mass-to-Charge (m/ z) Increase in mass (6Da) 3

32 non-deamidated peptide NTAYLQMNSLR NTAYLQMNSLR 5.9% NTAYLQMNSLR.23% NTAYLQMNSLR 5.5% NTAYLQMNSLR.97% NTAYLQMNSLR.24% NTAYLQMNSLR 2.5% NTAYLQMNSLR.2% Separation of Deamidated Peptides AdvanceBio Peptide Plus Column NTAYLQMNSLR Deamidated peptides ASQDVNTAVAWYQQKPGK Non-deamidated peptide Relative % deamidation = 9.% Deamidated peptide EIC ASQDVNTAVAWYQQKPGK NTAYLQMNSLR peptide Relative % of Deamidation =.2% 5.9% Non-deamidated peptide Relative % deamidation = 9.% ASQDVNTAVAWYQQKPGK peptide Relative % of Deamidation = 9.% 32

33 Separation of Deamidated Peptides Traditional silica columns don t resolve deamidation as well as charged surface columns. VVSVLTVLHQDWLnGK or VVSVLTVLHqDWLNGK m/z , doubly charged peptide Traditional Silica AdvanceBio Peptide Plus Sub 2 µm Sub 2 µm column requires much higher back pressure to achieve similar separation. Determination of deamidated peptides is an important goal of peptide mapping. Chromatographic resolution is important. MS/MS confirms which peak corresponds to which deamidation site. AdvanceBio Peptide Plus enhances analysis because it has higher selectivity for deamidated forms of peptide over the normal form. 33

34 Separation of Glycopeptides AdvanceBio Peptide Plus Column Non-glycosylated 3 x 2.5 EEEQYNSTR peptide EEEQYNSTR BioConfirm results.5 3 x EEEQYNSTR+G 5 x EEEQYNSTR+GF Glycosylated x x 4.2 EEEQYNSTR+GF Relative quantification GF = 45.4% GF = 4.6% G2F =.% G = 3.79% EEEQYNSTR+G2F.2 EIC Counts vs. Acquisition Time (min) 34

35 Critical Quality Attributes & Testing Methods Not just used for monoclonal antibodies same techniques are used for any potentially therapeutic protein RP Disulfide Shuffling SEC Aggregation Pyro- Glutamate IEC LC/MS Intact mass Fragment mass Identification PTM ID & locations Glycan ID Glycosylation (G, G, G2) HILIC Fragmentation (Hinge) RP Deamidation /Oxidation IEC With a Multi-Attribute Method, peptide mapping can monitor many of these CQAs simultaneously. Truncation (Lys,, 2) IEC 35

36 % modification % modification Multi-Attribute Method (MAM) 5 HILIC RP Glycans monitored % GF 44.8 GF 44.7 G2F 8.9 G RP Heavy chain HILIC MAM (Pep Map) GF GF G2F G Comparison to traditional methods Deamidation Oxidation Deamidations and Oxidation monitored by the MAM (Pep Map) CEX 36

37 Choosing a Column Chemistry For LC/MS work, AdvanceBio Peptide Plus with formic acid is the first choice. Best peak shape with formic acid, high peak capacity, high mass load tolerance, excellent PTM resolution (especially deamidation), peak shape and recovery of hydrophobic peptides, unique selectivity Exception : Sample is especially rich in small, hydrophilic peptides. Poor retention of small, hydrophilic peptides is a feature common to charged surface columns. In this case, try AdvanceBio Peptide Mapping or Eclipse Plus C8 first. Exception 2: Different selectivity is needed to separate a key pair. Charged surface chemistry AdvanceBio Peptide Plus vs Regular silica chemistry AdvanceBio Peptide Mapping Eclipse Plus RRHD ZORBAX 3 37

38 Method Development Tips & Reminders Bonded Phase: C8 is routinely used. Try AdvanceBio Peptide Plus first; for alternate selectivity or highly hydrophilic samples try AdvanceBio Peptide Mapping or a ZORBAX column. Column dimension: Good start with 2.mm 5mm, for higher resolution use longer column Gradient: Acetonitrile : Water with.% formic acid, other organic solvent substitutions can be used for different selectivity Starting gradient time: -4% in 3min (.3%/min) Temperature: Higher column temperature can dramatically improve both resolution and recovery (6 C max) Desalt peptide mixture prior to injection Sample handling may cause artifacts (peptide modifications) 38

39 Troubleshooting Reasons for < % Sequence Coverage Question to ask: Looking at the protein sequence, what s missing? Very small and/or very hydrophilic peptides? If using AdvanceBio Peptide Plus, try AdvanceBio Peptide Mapping for better retention and/or resolution. Very large and/or very hydrophobic peptides? Can you go to a higher percent organic mobile phase? Are peptides sticking to sample tubes or otherwise lost during sample preparation? Or on the LC? If using AdvanceBio Peptide Mapping, try AdvanceBio Peptide Plus - May even need to consider a C8 column rather than C8 Very large, or very small peptides of any hydrophobicity? Consider a different digestion enzyme 39

40 More Information How-to Guide Application Notes: LC/MS Analysis of Peptide Mapping with Formic Acid Ion-Pairing Agent ( EN) Enhancing the Quality of Peptide Mapping Separation for the Analysis of Post- Translational Modifications ( EN) 4

41 C o unts Standards & Reagents Peptide Standard (p/n ) x Blank A cquisition Time (min) 7 Trypsin Digest Methylated BSA Standard (p/n G99-85) 9 8. Bradykinin frag Bradykinin 3. Angiotensin II (human) 4. Neurotensin 5. Angiotensin I (human) 6. Renin substrate porcine 7. [Ace-F-3,-2 H-] Angiotensinogen (-4) 8. Ser/Thr Protein Phosphatase (5-3) 9. [F4] Ser/Thr Protein Phosphatase (5-3). Melittin (honey bee venom) HSA peptides Standard (p/n G ) Trypsin. AAFTE[CAM][CAM]QAADK 2. YLYEIAR 3. LVNEVTEFAK 4. KVPQVSTPTLVEVSR 5. RP[CAM]FSALEVDETYVPK 6. AVMDDFAAFVEK 7. HPYFYAPELLFFAK 4

42 Summary MS-compatible AdvanceBio Peptide Plus column delivers high peak capacity with sharp and narrow peaks using MS-friendly formic acid modifier mobile phase conditions. AdvanceBio Peptide Plus and AdvanceBio Peptide Mapping are superficially porous columns that yield low back pressures & STM-like performance, allowing peptide mapping separations to be run on both HPLC and UHPLC systems Well-resolved PTM modified peptide peaks enabled reliable mab peptide maps and development of Multi-Attribute Methods 42

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC Analysis of Intact and Fragmented mabs and ADC Application Note Biotherapeutics and Biologics Author Suresh Babu C.V. Agilent

More information

Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns

Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns Anne Blackwell Bio Columns Product Support Scientist Suresh Babu Senior Application

More information

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF Application Note Author David L. Wong Agilent Technologies, Inc. Santa Clara, CA, USA Introduction Monoclonal

More information

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS Application Note BioPharma Authors Alex Zhu, James Martosella, and Phu T Duong Agilent Technologies, Inc Introduction Peptide

More information

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS Agilent AdvanceBio Columns ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS with Agilent ZORBAX RRHD 3Å 1.8 µm columns ns Rapid resolution high definition columns for UHPLC protein and peptide separations

More information

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany D-LC/MS Characterization of Charge Variants Using Ion Exchange and Reversed-Phase Chromatography Multiple Heart-Cutting D-LC Analysis of Innovator versus Biosimilar Monoclonal Antibodies Application Note

More information

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides High-pH-stable, superficially porous particle columns for LC/UV and LC/MS Application Note Biologics and Biosimilars Authors

More information

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1 Routine Characterization of mabs and Other Proteins Patrick Boyce Biopharmaceutical Marketing Manager Europe and India 2011 Waters Corporation 1 Agenda Why? What scientific challenges? Technology Example

More information

mabs and ADCs analysis by RP

mabs and ADCs analysis by RP mabs and ADCs analysis by RP Shanhua Lin, Ph.D. The world leader in serving science Protein and mab Separation by HPLC Size difference? YES Size Exclusion Chromatography (SEC) MAbPac SEC-1 NO NO Charge

More information

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography Characterize Fab and Fc Fragments by Cation-Exchange Chromatography Application Note Biologics and Biosimilars Authors Isabel Vandenheede, Emmie Dumont, Pat Sandra, and Koen Sandra Research Institute for

More information

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF Application Note Authors Xianming Liu, Wei Zhang, Yi Du, Sheng Yin, Hong Que, and Weichang Zhou WuXi AppTec iopharmaceuticals

More information

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column Disulfide Linkage Analysis of IgG1 using an Agilent 126 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column Application Note Biotherapeutics & Biosimilars Author M. Sundaram

More information

Rapidly Characterize Antibody- Drug Conjugates and Derive Drug-to-Antibody Ratios Using LC/MS

Rapidly Characterize Antibody- Drug Conjugates and Derive Drug-to-Antibody Ratios Using LC/MS Rapidly Characterize Antibody- Drug Conjugates and Derive Drug-to-Antibody Ratios Using LC/MS Ning Tang, Ph.D. Agilent Technologies Santa Clara, California, USA Heterogeneity in ADCs Complexity T-DM1 (Genentech)

More information

Characterization of Glycosylation in the Fc Region of Therapeutic Recombinant Monoclonal Antibody

Characterization of Glycosylation in the Fc Region of Therapeutic Recombinant Monoclonal Antibody Characterization of Glycosylation in the Fc Region of Therapeutic Recombinant Monoclonal Antibody Application Note BioPharma Authors James Martosella, Phu Duong, and Alex Zhu Agilent Technologies, Inc.

More information

Peptide Mapping: A Quality by Design (QbD) Approach

Peptide Mapping: A Quality by Design (QbD) Approach Peptide Mapping: A Quality by Design (QbD) Approach Application Note Bio-Pharmaceutical Authors Sreelakshmy Menon and Suresh babu C.V. Agilent Technologies, Inc. Richard Verseput S-Matrix Corporation Abstract

More information

Advanced QA/QC characterization MS in QC : Multi Attribute Method

Advanced QA/QC characterization MS in QC : Multi Attribute Method Advanced QA/QC characterization MS in QC : Multi Attribute Method Global BioPharma Summit The world leader in serving science A Complex Problem: Drug Safety and Quality Safety Is the product safe to use?

More information

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS Application Note Biopharmaceuticals and Biosimilars Authors Emmie Dumont, Isabel Vandenheede, Pat Sandra, Koen Sandra Research

More information

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns Hongwei Xie, Martin Gilar, and Jeff Mazzeo Waters Corporation, Milford, MA U.S. APPLICATION BENEFITS The ACQUITY UPLC

More information

Agilent BioHPLC Columns PROTEIN IDENTIFICATION AND IMPURITY PROFILING USING REVERSED-PHASE HPLC/UHPLC

Agilent BioHPLC Columns PROTEIN IDENTIFICATION AND IMPURITY PROFILING USING REVERSED-PHASE HPLC/UHPLC Agilent BioHPLC Columns PROTEIN IDENTIFICATION AND IMPURITY PROFILING USING REVERSED-PHASE HPLC/UHPLC REVERSED-PHASE HPLC/UHPLC Agilent can boost your accuracy and productivity Reversed-phase is used to

More information

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs Technical Overview Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs Authors Stephen Madden, Crystal Cody, and Jungkap Park Agilent Technologies, Inc. Santa Clara, California,

More information

Analysis and Purification of Polypeptides by Reversed-Phase HPLC

Analysis and Purification of Polypeptides by Reversed-Phase HPLC Analysis and Purification of Polypeptides by Reversed-Phase HPLC Reversed-phase HPLC is a valuable tool for the analysis and purification of proteins and peptides. It is effective in separating peptide

More information

The clearly better choice

The clearly better choice Agilent Accurate-Mass 6500 Series Q-TOF and 600 Series TOF LC/MS Systems The clearly better choice in TOF and Q-TOF LC/MS Our measure is your success. products applications soft ware services The unmatched

More information

Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules

Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules Add a New Dimension to your Research Capability with Agilent s New Drift Ion Mobility QTOF System David Wong, Ph.D. Sr. Application

More information

Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns

Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns Michael McGinley, Jeff Layne, and Vita Knudson Phenomenex, Inc., 411 Madrid Ave.,Torrance,

More information

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility Technical Overview Introduction Agilent AdvanceBio SEC columns are a new family of size exclusion chromatography (SEC) columns

More information

High-Throughput Peptide Mapping with the Vanquish UHPLC System and the Q Exactive HF Mass Spectrometer

High-Throughput Peptide Mapping with the Vanquish UHPLC System and the Q Exactive HF Mass Spectrometer High-Throughput Peptide Mapping with the Vanquish UHPLC System and the Q Exactive HF Mass Spectrometer Martin Samonig 1, Kai Scheffler 2, Remco Swart 1, and Jonathan Josephs 3 1 Thermo Fisher Scientific,

More information

Antibody Analysis by ESI-TOF LC/MS

Antibody Analysis by ESI-TOF LC/MS Application Note PROTEOMICS METABOLOMICS GENOMICS INFORMATICS GLYILEVALCYSGLUGLNALASERLEUASPARG CYSVALLYSPROLYSPHETYRTHRLEUHISLYS Antibody Analysis by ESI-TOF LC/MS Authors Lorenzo Chen, Merck & Company,

More information

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb µm Column Application Note BioPharma Authors Xiaomi Xu and Phu T Duong Agilent Technologies, Inc. Abstract Nearly all proteins undergo

More information

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions Screening and Confirmation Chemical Analysis Solution Unit November, 2009 Page 1 Agilent s New 6540 Ultra High

More information

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover columns ProSwift Reversed-Phase Monolith Columns for Protein Analysis ProSwift reversed-phase columns use a unique monolith technology for fast, high-resolution HPLC and LC/MS separations of proteins.

More information

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column Application Note Bio-Pharmaceutical Authors M. Sundaram Palaniswamy and Andrew Coffey Agilent Technologies,

More information

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit Dr. Jerry Zweigenbaum Senior Applications Scientist Food Safety Page 1 Agilent 1260 LC SampliQ Extraction and Dispersive

More information

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube Application Note Environmental Authors Don Noot, Ralph Hindle Vogon Laboratory Services Cochrane, AB

More information

Reversed Phase Solutions for the Analysis of Proteins, Peptides, and Oligonucleotides

Reversed Phase Solutions for the Analysis of Proteins, Peptides, and Oligonucleotides Reversed Phase Solutions for the Analysis of Proteins, Peptides, and Oligonucleotides The line, which includes and Proteo, offers various reversed phase solutions for biochromatography. With these two

More information

Application Note. Abstract. Authors. Introduction. Environmental

Application Note. Abstract. Authors. Introduction. Environmental EPA Method 538: Determination of Selected Organic Contaminants in Drinking Water by Direct Aqueous Injection with the Agilent 646 Triple Quadrupole LC/MS System Application Note Environmental Authors Imma

More information

SMART Digest Kit User Manual. Version 2

SMART Digest Kit User Manual. Version 2 SMART Digest Kit User Manual Version 2 XX21543 Revision A August 2016 SMART Digest Kit Delivering simple, fast and reproducible digestion of proteins Thermo Scientific SMART Digest kits are designed for

More information

Tony Mire-Sluis Vice President, Corporate, Product and Device Quality Amgen Inc

Tony Mire-Sluis Vice President, Corporate, Product and Device Quality Amgen Inc The Regulatory Implications of the ever increasing power of Mass Spectrometry and its role in the Analysis of Biotechnology Products Where do we draw the line? Tony Mire-Sluis Vice President, Corporate,

More information

Utilizing novel technology for the analysis of therapeutic antibodies and host cell protein contamination

Utilizing novel technology for the analysis of therapeutic antibodies and host cell protein contamination Utilizing novel technology for the analysis of therapeutic antibodies and host cell protein contamination Kelli Jonakin, Ph.D. Senior Field Application Scientist, Seattle, WA Eric Johansen, Ph.D. Senior

More information

Method Translation in Liquid Chromatography

Method Translation in Liquid Chromatography Method Translation in Liquid Chromatography Technical Overview Abstract Ronald E. Majors Agilent Technologies, Inc. 2850 Centerville Rd Wilmington, DE 19808 USA With the recent emphasis on high performance

More information

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI with the Biopharmaceutical Platform Solution with UNIFI Vera B. Ivleva, Ying Qing Yu, Scott Berger, and Weibin Chen Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S The ability to

More information

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS Zhiqi Hao, 1 Yi Zhang, 1 David Horn, 1 Seema Sharma, 1 Shiaw-Lin

More information

Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite. Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct.

Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite. Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct. Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct. 12, 211 Outline Orbitrap Mass Spectrometer in mab Characterization Intact

More information

ProSEC 300S. Protein Characterization columns

ProSEC 300S. Protein Characterization columns ProSEC 300S Protein Characterization columns Agilent s ProSEC 300S is a silica-based material specifically designed for the analysis of proteins by aqueous size exclusion chromatography. With a proprietary

More information

Thermo Scientific Technical Resources Document 1.5. LC Columns and Accessories. for Biomolecules

Thermo Scientific Technical Resources Document 1.5. LC Columns and Accessories. for Biomolecules 1.5 1.0 0.5 Thermo Scientific Technical Resources Document LC Columns and Accessories for Biomolecules Section Contents Introduction...4-002 Bio Columns Selection Guide...4-003 HPLC s for Biomolecules...4-004

More information

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics Catalin Doneanu,, Ph.D. Biopharmaceutical Sciences, Waters September 16, 2009 Mass Spec 2009 2009 Waters Corporation Host Cell Proteins

More information

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping. Thermo Scientific Peptide Mapping Workflows Upgrade Your Maps Fast, confident and more reliable peptide mapping. Smarter Navigation... Peptide mapping is a core analytic in biotherapeutic development.

More information

MassPREP On-Line Desalting Cartridge

MassPREP On-Line Desalting Cartridge CONTENTS I. INTRODUCTION II. INSTALLING THE MASSPREP ON-LINE DESALTING CARTRIDGE INTO THE SENTRY.1 X 1 MM GUARD COLUMN HOLDER III. RECOMMENDED LC/MS SYSTEM CONFIGURATION TO MINIMIZE MS SOURCE CONTAMINATION

More information

Thermo Scientific LC Columns for Biomolecules

Thermo Scientific LC Columns for Biomolecules LC Columns and Accessories Thermo Scientific Chromatography Columns and Consumables 2014-2015 Thermo Scientific LC Columns for Biomolecules The diversity of biological samples in terms of compound structure

More information

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development Thermo Scientific Solutions for Intact-Protein Analysis Better, Faster Decisions for Biotherapeutic Development Quickly and Accurately Assess Product Quality and Safety Therapeutic proteins and monoclonal

More information

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany New Features of the Agilent Method Scouting Wizard for Automated Method Development of Complex Samples Analysis of Large Data Sets by Method Scouting Reports and Automated Adjustment of Flow Rates and

More information

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus Robert Birdsall, Thomas Wheat, and Weibin Chen Waters Corporation,

More information

Zwitterion Chromatography ZIC

Zwitterion Chromatography ZIC Zwitterion Chromatography ZIC A novel technique, with unique selectivity, suitable for preparative scale separations? PhD Einar Pontén What is Zwitterion Chromatography? Our definition: Liquid chromatography

More information

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF rapiflex Designed for Molecules that Matter. Innovation with Integrity MALDI TOF/TOF rapiflex TM The first MALDI-TOF/TOF that adapts to your needs. The rapiflex is the most advanced MALDI TOF/TOF system

More information

Thermo Scientific BioLC Columns. Monoclonal antibody. characterization

Thermo Scientific BioLC Columns. Monoclonal antibody. characterization Thermo Scientific BioLC Columns Monoclonal antibody characterization Innovative technologies and workflows for increasing productivity and throughput Table of Contents Characterization of Monoclonal Antibodies

More information

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC Quality-by-Design-Based Method Development Using an Agilent 129 Infinity II LC An Efficient Method Development Workflow Combined with ISET-mediated Method Transfer Under Waters Empower 3 CDS Control Application

More information

Analysis of Monoclonal Antibody Digests with the Agilent 1290 Infinity 2D-LC Solution Part 2: HILIC RPLC-MS

Analysis of Monoclonal Antibody Digests with the Agilent 1290 Infinity 2D-LC Solution Part 2: HILIC RPLC-MS Analysis of Monoclonal Antibody Digests with the Agilent 90 Infinity D-LC Solution Part : HILIC RPLC-MS Application Note Biotherapeutics & Biosimilars Authors Gerd Vanhoenacker, Koen Sandra,, Isabel Vandenheede,,

More information

Method Development Considerations for Reversed-Phase Protein Separations

Method Development Considerations for Reversed-Phase Protein Separations Method Development Considerations for Reversed-Phase Protein Separations Hillary B. Hewitson, Thomas E. Wheat, Paula Hong, Kenneth J. Fountain APPLICATION BENEFITS n The BEH00 C 4 chemistry is available

More information

Agilent 6430 Triple Quadrupole LC/MS System

Agilent 6430 Triple Quadrupole LC/MS System Agilent 6430 Triple Quadrupole LC/MS System Ideal Quantitative LC/MS for UHPLC with Dynamic MRM and Fast Polarity Switching, plus Unsurpassed Sensitivity with Chip LC Summary The Agilent 6430 Triple Quadrupole

More information

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System Heart-cut 2D-LC/M approach for pharmaceutical impurity identification using an Agilent 640 Q-TF LC/M ystem Application ote Pharmaceuticals Author iji Joseph Agilent Technologies, Inc. Bangalore, India

More information

Genotoxicity is the property of a compound

Genotoxicity is the property of a compound Impurities Analysis in Pharmaceuticals: Genotoxicity is the property of a compound known to have irreversible effects on the structure and functionality of the DNA in cells and cause DNA loss, DNA replication

More information

Analysis of biomolecules by SEC and Ion-Exchange UPLC

Analysis of biomolecules by SEC and Ion-Exchange UPLC Analysis of biomolecules by SEC and Ion-Exchange UPLC Anders Feldthus, Waters Nordic 2011 Waters Corporation 1 Waters Commitment To develop, commercialize and market columns that when used on Waters ACQUITY

More information

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates Julia Baek, Shanhua Lin, Xiaodong Liu, Thermo Fisher Scientific, Sunnyvale, CA Application Note 2126 Key Words Size exclusion

More information

CaptiveSpray nanobooster

CaptiveSpray nanobooster CaptiveSpray nanobooster The Revolution in Proteomics Ionization Innovation with Integrity LC-MS Source The Key to Performance and Reliability for nano flow MS Bruker CaptiveSpray principle: Stable and

More information

High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers. The world leader in serving science

High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers. The world leader in serving science High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers The world leader in serving science Goals Explore the capabilities of High Resolution Accurate Mass

More information

Využití cílené proteomiky pro kontrolu falšování potravin: identifikace peptidových markerů v mase pomocí LC- Q Exactive MS/MS

Využití cílené proteomiky pro kontrolu falšování potravin: identifikace peptidových markerů v mase pomocí LC- Q Exactive MS/MS Využití cílené proteomiky pro kontrolu falšování potravin: identifikace peptidových markerů v mase pomocí LC- Q Exactive MS/MS Michal Godula Ph.D. Thermo Fisher Scientific The world leader in serving science

More information

PolyCAT A For Cation-Exchange

PolyCAT A For Cation-Exchange PolyCAT A For Cation-Exchange The PolyCAT A is made though a unique process for attaching Poly(aspartic acid) covalently to silica. Proteins elute from this polypeptide coating in sharp peaks with little

More information

BioConfirm B Presentation

BioConfirm B Presentation BioConfirm B.08.00 Presentation 1 Major Enhancements to Increase Your Productivity The Latest Version of our BioConfirm Product, B.08.00 BioConfirm is protein and peptide characterization software using

More information

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website:  Published in November 2013 5-100 Innovation Way Newark, DE 19711, USA Tel:302-3661101 Fax:302-3661151 Website: www.sepax-tech.com Published in November 2013 P/N SECKIT-7830 These Phases are developed based on innovative surface

More information

Size Exclusion Chromatography/ Mass Spectrometry Analysis of Antibody Drug Conjugates Using the Agilent 1260 Infinity II Bio-Inert LC

Size Exclusion Chromatography/ Mass Spectrometry Analysis of Antibody Drug Conjugates Using the Agilent 1260 Infinity II Bio-Inert LC Size Exclusion Chromatography/ Mass Spectrometry Analysis of Antibody Drug Conjugates Using the Agilent 126 Infinity II Bio-Inert LC Application Note Biologics & Biosimilars Author Sonja Schneider Agilent

More information

Promix TM. Enter a New Era in Biomolecule Analysis with. Columns. Unsurpassed Selectivity and Peak Capacity for Peptides and Proteins

Promix TM. Enter a New Era in Biomolecule Analysis with. Columns. Unsurpassed Selectivity and Peak Capacity for Peptides and Proteins Promix TM Enter a New Era in Biomolecule Analysis with Promix TM Columns Unsurpassed electivity and Peak Capacity for Peptides and Proteins Applications: Proteomics Peptide/Protein Analysis Peptide/Protein

More information

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution Rapidly Identify Major Catabolites with the SCIEX X500R QTOF System and MetabolitePilot TM 2.0 Software Ian Moore and Jinal Patel

More information

Accucore. Ultimate Core Performance LC Column Technology to Maximize Your Investment. Dave Jarzinski. October 2011

Accucore. Ultimate Core Performance LC Column Technology to Maximize Your Investment. Dave Jarzinski. October 2011 Accucore Ultimate Core Performance LC Column Technology to Maximize Your Investment Dave Jarzinski Thermo Fisher Scientific Account Manager Greater Boston/Cambridge & North Phone: 978-408-1576 Email: dave.jarzinski@thermofisher.com

More information

Trastuzumab Glycan Batch-to-Batch Profiling using a UPLC/FLR/Mass Spectrometry Platform

Trastuzumab Glycan Batch-to-Batch Profiling using a UPLC/FLR/Mass Spectrometry Platform Trastuzumab Glycan Batch-to-Batch Profiling using a UPLC/FLR/Mass Spectrometry Platform Ying Qing Yu, Joomi Ahn, and Martin Gilar Waters Corporation, Milford, MA, U.S. APPLICATION BENEFITS Used together,

More information

Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins

Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins Esther Lewis, 1 Kevin Meyer, 2 Zhiqi Hao, 1 Nick Herold,

More information

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System Application Note Biologics & Biosimilars Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction Chromatography Agilent 126 Infinity II Bio-Inert System 7 6 5 4 5. 7.5

More information

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime EASY-Spray Columns Guidance for column set up and installation Tips to maximize column lifetime EASY-Spray Column Tips and Tricks This document provides guidance for Thermo Scientific EASY-Spray column

More information

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis APPLICATION NOTE 72362 Lifetime stability of size exclusion chromatography columns for protein aggregate analysis Authors Amy Farrell 1, Craig Jakes 1, Alexander Ley 2, Mauro De Pra 2, Frank Steiner 2,

More information

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA LECTURE-06 PROTEIN PURIFICATION AND PEPTIDE ISOLATION USING CHROMATOGRAPHY TRANSCRIPT Welcome to the proteomics course. Today, we will talk about protein purification and peptide isolation using chromatography

More information

Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS

Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS Sensitive workflow for the detection of PTMs in biological samples from small sample volumes Klaus Faserl, 1 Bettina Sarg, 1

More information

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study MagSi Beads Magnetic Silica Beads for Life Science and Biotechnology study MagnaMedics Diagnostics B.V. / Rev. 9.2 / 2012 Wide range of products for numerous applications MagnaMedics separation solutions

More information

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column mab Titer Analysis with the Agilent Bio-Monolith Protein A Column Application Note Biopharmaceuticals and Biosimilars Authors Emmie Dumont, Isabel Vandenheede, Pat Sandra, and Koen Sandra Research Institute

More information

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Protein-Pak Hi Res HIC Column and HIC Protein Standard Protein-Pak Hi Res HIC Column and HIC Protein Standard CONTENTS I. INTRODUCTION II. a. Mobile Phase b. Flow Direction CONNECTING COLUMN TO LC SYSTEM I. INTRODUCTION This offering contains non-porous, polymethacrylate-based

More information

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider Combining small-scale purification and analysis of monoclonal antibodies on one instrument Protein purification with high-volume injection using the Agilent 126 Infinity Bio-inert Quaternary LC System

More information

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany Quantification of trace-level herbicides in drinking water by online enrichment with the Agilent Infinity Series Online-SPE Solution and Triple Quadrupole MS Detection Application Note Environmental Author

More information

SMART Digest compared to classic in-solution digestion of rituximab for in-depth peptide mapping characterization

SMART Digest compared to classic in-solution digestion of rituximab for in-depth peptide mapping characterization APPLICATION NOTE Digest compared to classic in-solution digestion of rituximab for in-depth peptide mapping characterization No. 1159 Authors: Martin Samonig 1, Alexander Schwahn 2, Ken Cook 3, Mike Oliver

More information

Proteomics. Proteomics is the study of all proteins within organism. Challenges

Proteomics. Proteomics is the study of all proteins within organism. Challenges Proteomics Proteomics is the study of all proteins within organism. Challenges 1. The proteome is larger than the genome due to alternative splicing and protein modification. As we have said before we

More information

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma Yun Wang Alelyunas, Mark D. Wrona, Jim Murphy, Angela Doneanu, Gregory

More information

Martin Gilar Waters Corporation, Milford, MA, U.S. Origins of synthetic oligonucleotides impurities. Lab-scale isolation options

Martin Gilar Waters Corporation, Milford, MA, U.S. Origins of synthetic oligonucleotides impurities. Lab-scale isolation options LIGNUCLETIDE SEPARATIN TECHNLGY: SYNTHESIS CHALLENGES AND HPLC ISLATIN PTINS Martin Gilar Waters Corporation, Milford, MA, U.S. INTRDUCTIN rigins of synthetic oligonucleotides impurities Use of synthetic

More information

Algorithm for Matching Additional Spectra

Algorithm for Matching Additional Spectra Improved Methods for Comprehensive Sample Analysis Using Protein Prospector Peter R. Baker 1, Katalin F. Medzihradszky 1 and Alma L. Burlingame 1 1 Mass Spectrometry Facility, Dept. of Pharmaceutical Chemistry,

More information

MAbPac SCX-10 Columns

MAbPac SCX-10 Columns User Manual MAbPac SCX-10 Columns 065393 Revision 09 October 2015 For Research Use Only. Not for use in diagnostic procedures. Product Manual for MAbPac SCX-10, 10µm Analytical Column (10μm, 9 x 250 mm,

More information

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system Application Note Biopharmaceuticals Authors Arunkumar Padmanaban and Sreelakshmy Menon

More information

Increasing MS Sensitivity for Proteomics

Increasing MS Sensitivity for Proteomics Increasing MS Sensitivity for Proteomics Discovery to Pathways Analysis: Using Agilent 6550 ifunnel Q-TOF Vadi Bhat, Ph.D. Senior Applications Scientist Agilent Technologies Wilmington, DE, USA 1 April

More information

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution Rapidly Identify Top Metabolites with the SCIEX X500R QTOF System and MetabolitePilot TM 2.0 Software Shaokun Pang and Ian Moore SCIEX,

More information

Monoclonal Antibody Characterization Achieving Higher Throughput and Productivity

Monoclonal Antibody Characterization Achieving Higher Throughput and Productivity Monoclonal Antibody Characterization Achieving Higher Throughput and Productivity Dionex Solutions to Accelerate Monoclonal Antibody R&D and Characterization The throughput and productivity challenge Increasing

More information

Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow

Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow Technical Note Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow Introduction The complex nature of proteomics samples requires high-resolution separation methods

More information

Choosing the Right Calibration for the Agilent Bio SEC-3 Column

Choosing the Right Calibration for the Agilent Bio SEC-3 Column Choosing the Right Calibration for the Agilent Bio SEC-3 Column Application Note Biotherapeutics & Biosimilars Author Keeley Mapp Agilent Technologies, Inc Introduction Size exclusion chromatography (SEC)

More information

LabChip GXII: Antibody Analysis

LabChip GXII: Antibody Analysis WHITE PAPER LabChip GXII: Antibody Analysis Antibody Analysis using microfluidic technology in high throughput Quality by Design Experiments Abstract Current initiatives in Process Analytical Technology

More information

BÜCHI Labortechnik AG

BÜCHI Labortechnik AG BÜCHI Labortechnik AG Purification BUCHI Chromatography History 1977: BUCHI Fraction Collector 1978: 1 st preparative chromatography system 2008: automated chromatography system 2014: automated high performance

More information

Thermo Scientific TSQ Quantum Access MAX

Thermo Scientific TSQ Quantum Access MAX www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Scientific TSQ Quantum Access MAX UNSURPASSED PRICE TO PERFORMANCE Superior

More information