New Advances in UHPLC -Resolution, Speed & Sensitivity
|
|
- Myles Norton
- 6 years ago
- Views:
Transcription
1 New Advances in UHPLC -Resolution, Speed & Sensitivity Enhancing Productivity with Agilent s Newest Instrumentation Patrick Cronan LC Applications Scientist Boston, MA September 14, 2012 Page 1
2 The 1290 Infinity Quaternary LC System How binary pump-like performance can enhance your lab efficiency 1290 Infinity DAD with 60mm cell (& HDR optional) 1290 Infinity TCC with broadest valve selectivity 1290 Infinity Autosampler (with Flexible Cube for lowest carry-over) 1290 Infinity Quaternary Pump Page 2 Page 2 September 24, 2012
3 Innovation: 1290 Infinity Quaternary Pump Quaternary Pump with Binary Pump-like Performance 1290 Infinity Quaternary Pump Boost Performance Highest accuracy and precision for composition and flow, with exceptionally low delay volume Save Time Accelerates transfer of existing HPLC methods to UHPLC Reduce Costs Outstanding UHPLC performance at HPLC-like costs of ownership Page 3
4 New Inlet-Mixer - based on JetWeaver technology 4 Page 4 Oct. 2011
5 1290 Infinity Quaternary Pump Various tools enabling the high performance Switchable Jet Weaver Mixer 4-channel Degasser Multi-Purpose- Valve MCGV (Multi- Channel-Gradient- Valve) Inlet-Weaver Pump Head In-line Filter 5 Page 5
6 Multipurpose valve functions for highest comfort Standard Application for standard Delay Volume 6 Page 6
7 Multipurpose valve functions for highest comfort Extra Mixing Volume for lowest baseline ripple (TFA applications) 7 Page 7
8 Multipurpose valve functions for highest comfort Automatic Purging 8 Page 8
9 Multipurpose valve functions for highest comfort Automatic filter backflush 9 Page 9
10 Agilent 1290 Infinity Quaternary Pump Specifications & Benefits Power Range For any kind of analysis Composition Accuracy and Precision < 0.15 % RSD or 0.02 min SD 0.4 % (1-99 % Composition B) High RT precision in gradient runs Flow Accuracy and Precision < 0.07 % RSD or 0.01 min SD 1.0 % or 10 µl High RT precision in isocratic runs Composition Range 1-99 % Wide analytical range Delay Volume < 350 µl For fast quaternary gradients Page 10
11 Composition Accuracy and Precision Step Gradient Analysis with Tracer Different mixtures (H2O, MeOH, ACN) at different pressures and different flow rates Full application range! 11 January, 26, 2012 Page 11
12 Flow and Composition Accuracy and Precision Isocratic analysis of Glucocorticoids 1: Hydrocortisone 2: Beclomethasonedi-proprionate 3: Hydrocortisone acetate Column: Agilent ZORBAX Eclipse Plus C18, 4.6 x 100 mm, 5 µm (p/n ) Mobile phase: Water/ Acetonitrile = 30/70 Flow rate: 1 ml/min Stop time: 5 min Injection vol.: 3 µl (needle wash for 3 sec) Column Temp.: 30 C DAD: 254/10 nm, (ref 400/ 80 nm), 20 Hz, slit 4 nm Page 12
13 Flow and Composition Accuracy and Precision Isocratic analysis of Glucocorticoids mau RT of compounds very sensitive regarding changes in mobile phase composition! Water/ACN 29:71 Water/ACN 31:69 Water/ACN 30:70 min Page 13
14 Accuracy and Precision Isocratic analysis of Glucocorticoids Specification (< 0.07 %) mau : Hydrocortisone 2: Beclomethasonedi-proprionate : Hydrocortisone acetate min Page 14
15 Agilent 1290 Infinity Quaternary Pump Specifications & Benefits Power Range For any kind of analysis Composition Accuracy and Precision < 0.15 % RSD or 0.02 min SD 0.4 % (1-99 % Composition B) High RT precision in gradient runs Flow Accuracy and Precision < 0.07 % RSD or 0.01 min SD 1.0 % or 10 µl High RT precision in isocratic runs Composition Range 1-99 % Wide analytical range Page 15
16 Composition Range Shallow gradient at low organic concentration CH 3 CH 3 O N N O N N N H N 3 C O H 1: Theophylline H 3 C N N O CH 3 2: Caffeine Column: Agilent Poroshell 120 EC-C18, 4.6 x 50 mm, 2.7 µm (p/n ) Mobile phase: A = Water / B = Acetonitrile Gradient: Flow rate: Stop time: 2 12 % B in 5min 2 ml/min 5 min Injection vol.: 5 µl Column Temp.: 40 C DAD: 254/10 nm, (ref. 360/ 100 nm), 20 Hz Page 16
17 Composition Range Shallow gradient at low organic concentration mau CH 3 CH O N N N H N 3 C O H 1: Theophylline O H 3 C N N N N O CH 3 2: Caffeine min Page 17
18 Composition Range Shallow gradient at low organic concentration 0.5 Retention time precision 0.4 RSD RT (%) Specification (< 0.15 %) Theophylline Caffeine Infinity Quat. System Page 18
19 Composition Range Shallow gradient at low organic concentration Retention time precision RSD RT (%) Specification (< 0.15 %) Theophylline Caffeine Infinity Quat. System 1260 Infinity Quat. System Quat. UHPLC Other vendor Page 19
20 Composition Range Shallow gradient at low organic concentration mau 250 Step gradient 1 % steps from 0 to 10 % Infinity Quaternary system Quaternary UHPLC from other vendor Page 20
21 Ternary/Quaternary Gradients Blend Assist You need different concentrations of modifiers in your analysis, would like to have just one stocksolution and do online dilution to profite from the quaternary mixing capability of your pump? Here is a simple tool BlendAssist! Water Water 1% TFA Desired method conditions - example: 1. 5 to 95% gradient of ACN with 0.1% TFA in Water and 0.08% TFA in ACN % gradient of ACN with 0.5% TFA in Water and 0.4% TFA in ACN Without BlendAssist you need to either pre-mix the required solvents or by using stock-solutions of TFA in Water and ACN to program complex gradients (%A, B, C, D). ACN ACN 1% TFA With BlendAssist: just program your binary organic/aqueous gradient and define the dilution factor! Page 21
22 Ternary/Quaternary Gradients Blend Assist - simple Tool for Online-Dilution of Modifiers and Gradient Set-Up BlendAssist - Solvent/modifier channel definition Page 22
23 Buffer Advisor Software Quaternary mixing 23 Page 23 September 24, 2012
24 1260 Infinity Bio-inert HPLC What is similar compared to standard 1260 Infinity Quaternary LC? Pumping performance, gradient performance Pumping Specifications Detector, Autosampler Performance and Specs Overall System Robustness TCC specs 600 bar also for fast or high resolution Bioseparations Modular flexibility maintained 24 Page 24 September 24, 2012
25 1260 Infinity Bio-inert HPLC What is different compared to standard 1260 Infinity Quaternary LC Pump titanium based, no SST Autosampler metal-free Capillaries and connections metal-free Detector Flow Cell metal-free ph-range 1-13, short term ph 14 Active Seal wash included in pump Low pressure is possible Wide ph range High salt tolerance Lowest surface activity Bio-Inertness 25 Page 25 September 24, 2012
26 New Capillary Design Ensures Bio-inertness Capillaries: Needle: Metal cladded PEEK capillary New capillary technolgy enables 600 bar AND is completely metal free!! SST housing for robustness PEEK and ceramic for metal free sample path 26 Page 26 September 24, 2012
27 Page 27
28 Page 28
29 Buffer Advisor Software Workflow 1: Select Buffer and Gradient Solution 2: Enter Gradient Timetable 3: Review Composition of Stock Solutions and Adjust 4: Gradient Display Section: Process and Review Gradient 29 Page 29 September 24, 2012
30 Experimental Situation Page 30
31 Buffer Advisor Software Workflow Page 31
32 Buffer Advisor Software Timetable import into Chemstation 32 Page 32
33 Buffer Advisor Software ph scouting 33 Page 33
34 Buffer Advisor Software stable ph 34 Page 34
35 30x wider linear UV range - Quantification of widely different concentration levels in one single run Agilent 1200 Infinity High Dynamic Range (HDR) Solution Page 35
36 History of DAD Linearity Gain The last 30 years > Infinity HDR-DAD 30.0 >30X Linearity With HDR Gain Linearity to to to to to 1290/ to HDR 2.9 (1986) (1988) (1995) (2006) (2010) (2011) Detector Model (Intro Year) 36 Page 36 September 24, 2012
37 Optofluidic Waveguides: Max-Light Flow Cells Total-internal reflection in a non-coated fused silica fiber Mirror 1260 / 1290 Infinity DAD Grating Programmable or fixed slit Deuterium Lamp Max-Light Cartridge Cell 10 mm or 60 mm path length 1024 element diode-array 37 Page 37 September 24, 2012
38 Effects of path length increase Conventional flow cells: 10 mm pathlength small geom. cell volume (13 µl) high light transmission Peak Dispersion 60 mm pathlength large geom. cell volume (78 µl) lower light transmission - Loss of resolution - Loss of signal height Max-Light High Sensitivity cell: Optofluidic waveguides (total internal reflection) 60 mm pathlength 4 µl V dispersion volume 38 Page 38 September 24, 2012
39 10x Higher Sensitivity 1290/1260 Infinity DAD compare to 1200 Series DAD SL 30 mau Columns: 150 x 4.6mm Zorbax SB C18, 5µm Sample: Anthracene: 835 pg/µl Mobile phase: A: Water, B: Acetonitrile Elution: isocratic 80 % B /1290 Infinity DAD Injection volume: 5 µl Flow: 1.5 ml/min DAD: 251/4nm, Ref= 450/80nm, 2.5Hz, slit width 4nm /1290 DAD 60 mm 1200 DAD SL 10mm Series DAD / DAD SL min Height [mau] Noise [mau] Signal/ noise Increase 11.4 x Page September 24, 2012
40 30x Wider Linear Range with HDR-DAD 3.7 mm and 60 mm and Max-Light flow cell Detector Signal [AU/cm] 3.7 mm path-length 60 mm path-length Computing the signals from 60 mm path-length for the low concentration 3.7 mm path-length for the high concentration Conc [µg/ml] 40 Page 40 September 24, 2012
41 1290/1260 High Dynamic Range HDR Increasing Linear UV Range by >30x DAD 1: DAD 2: 60mm Clustered DAD 3.7mm Technology Cluster of two DADs DAD 1: 60 mm Cell for low concentrations DAD 2: 3.7 mm Cell for high concentrations Output: One, combined signal, normalized to 10 mm path length (HDR range: 0.6 x 10-6 to 6.7 AU/cm) vs for 1200 Series: 7 x 10-6 to 2 AU/cm) Control / Usability Like standard 1290/1260 DAD: Control, data analysis, reporting Investment Protection Existing 1290/1260 DAD can be upgraded (by 2nd DAD) Existing 1100/1200 Systems can be upgraded (by two 1290 or 1260 DAD) 41 Page 41 September 24, 2012
42 Fixed Dose Combinations From Roche Switzerland Fixed dose combinations: A combination of two or more APIs in a fixed ratio of doses Agilent 1200 (black): API 2: 10 µl injected Agilent 1200 (red): API 1: 100 µl injected Infinity HDR-DAD (blue): API 1 and 2 simultaneously: 70 µl injected API 2 API 1 42 Page 42 September 24, 2012
43 Fixed Dose Combinations From Roche Switzerland With the Agilent 1200 Infinity HDR- DAD we significantly decreased our turnaround time. We also get lower LODs and better area precision Dr. Rose-Marie Meier F. Hoffmann - La Roche AG Infinity HDR-DAD Agilent 1200 DAD 43 Page 43 September 24, 2012
44 2 Injections needed if a conventional DAD is used mau Paracetamol 1000 Vitamin C µl injection to determine the first 3 peaks Caffeine Chlorphenamine? min mau Vitamin C Paracetamol Detector saturation Outside the linear range 5µl injection to determine the last peak and further impurities The first 2 peaks are out of linear range 2000 Chlorphenamine 1000 Caffeine min 44 Page 44 September 24, 2012
45 2 Injections needed if a conventional DAD is used mau 1 Chlorphenamine DAD1 A, Sig=254,20 Ref=380,80 (SOP 98 GRI...0FEB\HDR_GRIPPO_OLD_20FEB \GRIPPO_1UL09.D) DAD1 A, Sig=254,20 Ref=380,80 (SOP 98 GRI...0FEB\HDR_GRIPPO_OLD_20FEB \GRIPPO_5UL10.D) 0.8 mau 20 Chlorphenamine Imp Imp min Imp 3 Red: 5µl injection with 21.8mAU peak height for Chlorphenamine Blue: 1µl injection with 3.7mAU peak height for Chlorphenamine Imp min 45 Page 45 Confidentiality Label September 24, 2012
46 Comparison of conventional DAD vs. HDR DAD, 5µl injection mau Vitamin C Detector saturation Outside the linear range Paracetamol Red conventional DAD: 2 peaks out of linear range with 5µl injection 2500 Green HDR-DAD: 2000 All peaks within linear range (up to 6AU) Caffeine Chlorphenamine min 46 Page 46 September 24, 2012
47 Comparison of LOD mau More reliable automated peak integration HDR DAD Conventional DAD min Compound LOD with S/N=3 for Conventional DAD LOD with S/N=3 for HDR- DAD solution Chlorphenamine ~1ng ~0.1ng 47 Page 47 September 24, 2012
48 mau Comparison of conventional DAD and HDR DAD, 5µl injection DAD1 K, Sig=254,20 Ref=380,80 (SOP 98 GRI...B\HDR_GRIPPO_HDR_21FEB \GRIPPO_HDR5UL09.D) DAD1 A, Sig=254,20 Ref=380,80 (SOP 98 GRI...0FEB\HDR_GRIPPO_OLD_20FEB \GRIPPO_5UL09.D) Vitamin C Paracetamol Caffeine Red conventional DAD: determination of impurities and chlorphenamine in a second run Chlorphenamine Blue HDR DAD: dermination of all peaks in one run 10 Imp 1 Imp 2 Imp 3 Imp min 48 Page 48
49 Comparison of area precision 3 Comparison of Area Precision RSD Area (%) HDR Signal Conv.DAD signal (1µl) Conv.DAD (5µl) HDR DAD 5µl injection volume for detemination of all compounds (blue) Conventional DAD: 1µl injection volume for determination of Vit C, paracetamol and Caffeine (orange) 5µl injection volume for determination of Chlorphenamine and further impurities (green) 49 Page 49 September 24, 2012
50 Intelligent System Emulation Technology (ISET) Page 50 Page 50 September 24, 2012
51 What is ISET? - Two components A. Best in class performance of the 1290 Infinity LC Broad power range, ultra-low delay volume, superior sensitivity, unmatched flow and composition accuracy Peak 3 Overlay of 10 runs RSD = % B. The revolutionary ISET emulation algorithm Full characterization of target LC systems Creation of emulation function F A Page 51 Page 51
52 Method Transferability: 1290 Infinity LC - System Emulation Technology Concept F A Emulated System A Select System to be emulated by a simple mouse click: Agilent 1100 Series Agilent 1200 Series LC Agilent 1260 Infinity LC Agilent 1220 Infinity LC Alliance (2012) Page 52 Page 52
53 Intelligent System emulation technology - How it works (1290 to 1200) mau Injection Same gradient conditions by moving the gradient and by emulating the gradient mixing behavior Programmed gradient 1290 gradient 1200 gradient min Page 53 Page 53
54 Intelligent System Emulation Technology ISET Implementation Select pump Select sampler Page 54 Page 54
55 Pesticides Column: 3 x 50 mm, 2.7 µm Poroshell Run time: 3.5 min mau Metamitron Chloridazone R s = 1.87 Cyanizine Simazine Chlortoluron Diuron Propazine Terbutylazine Prometryn 1290 System with iset R s = System R s = Binary System min 55 Page 55
56 Pesticides Column: 3 x 50 mm, 2.7 µm Poroshell Run time: 3.5 min 56 Page 56
57 Pesticides Column: 3 x 50 mm, 2.7 µm Poroshell Run time: 3.5 min 57 Page 57
58 Generic emulation - Limitations Example: 1290 to Vendor X mau Injection 250 Generic emulation: Move the gradient Programmed gradient 1290 gradient min Vendor X Page 58 Page 58
59 Generic emulation - Limitations Example: 1290 to Vendor X mau Injection Generic emulation: Move Move the the gradient gradient Does not consider the gradient mixing behavior (different curves) or delay volume changes because of pressure changes for pumps with damper. min Programmed gradient 1290 gradient Vendor x Page 59 Page 59
60 Method Transfer Possibilities Today - A) Adding physical volume (plumbing solution) Example: 1290 Infinity LC L dwell vol. 1100/1200 Quat Pump Advantages Works well for generic, slower analysis No Method change Disadvantages Requires hardware change, no flexibility Hardware change difficult in validated environment Requires manual determination of the dwell volume (Pumps with damper the dwell volume is not constant and depends on pressure) Page 60 Page 60
61 Method Transfer Possibilities Today - B) Isocratic Hold Example: 1290 to 1200 mau Injection Isocratic hold: move the gradient Does not consider the gradient mixing behavior (different curves) Programmed gradient 1290 gradient min 1200 gradient Page 61 Page 61
62 Method Transfer Possibilities Today - B) Isocratic Hold Example: 1290 to Series LC Binary Pump 1290 Infinity LC µl Delay Volume 1290 Infinity LC µl Delay Volume 1290 Infinity LC µl Delay Volume Page 62 Page 62
63 Method Transfer Possibilities Today - B) Isocratic Hold Example: 1290 to Infinity LC 1290 Infinity LC µl hold Advantages Flexibile, Isocratic Hold is part of the method Disadvantages Works not in all cases Requires manual determination of the dwell volume/ isocratic hold (Pumps with damper the dwell volume is not constant and depends on pressure) Requires modification of the methods (should be avoided in validated environment, but doesn t require revalidation USP Chapter <621>) Page 63 Page 63
64 Method transfer, pesticide example 2.1x100 mm Zorbax Eclipse Plus, 1.8 µm column, flow: 0,8 ml/min (A) 1100 Quaternary 400 bar 1 2, , ,11, (B) 1290 Infinity 1200 bar (C) 1290 Infinity 1200 bar with ISET Page 64 Page 64 September 24, 2012
65 1290 Quaternary Pump: Full 1290 Infinity LC Power range Summary Highest composition precision and accuracy across pressure and flow rate range Full application range with binary-like pump performance! 1290 Systems using ISET: Achieves higher productivity for method development Simplify your instrument to instrument method transfer while minimizing costs Run your legacy methods with ISET and use UHPLC speed for faster separations HDR DAD Solution: Determination of low and high dose drugs is possible in one run Improved Precision and Lower Detection Limits as compared to convention DAD Using Buffer Advisor with BioInert Quat System: Shortens and simplifies the workflow for ph scouting by using pre-validated buffer systems and dynamically mixed gradients Excellent tool using for automated ph scouting and accurate ion exchange chromatography 65 Page 65
66 Page 66
The Agilent 1260 Infinity BioInert Quaternary Pump. Scope of a low-pressure mixing UHPLC pump with Bio-Inert Capabilities
The Agilent 1260 Infinity BioInert Quaternary Pump Scope of a low-pressure mixing UHPLC pump with Bio-Inert Capabilities Patrick Cronan Applications Scientist Agilent Technologies Boston, MA 1 Comparison
More informationAnalytical Instrument Qualification According to USP <1058>: Requirements and Examples for the Agilent 1290 Infinity LC System
Analytical Instrument Qualification According to USP : Requirements and Examples for the Agilent 1290 Infinity LC System 1) USP : Scope, approach, requirements 2) Qualification Examples for
More informationPerformance characteristics of the 1260 Infinity Quaternary LC system
Performance characteristics of the 1260 Infinity Quaternary LC system The new standard in HPLC Technical Overview Introduction The Agilent 1260 Infinity LC system consists of modular units that operate
More informationPeptide Mapping. Hardware and Column Optimization
Peptide Mapping Hardware and Column Optimization 1 Peptide Map: definition Analysis of PEPTIDES that are generated from the digestion or fragmentation of a protein or mixture of PROTEINS, by ELECTROPHORESIS;
More informationTechnical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany
Transferring methods to the Agilent 129 Infinity LC System using Intelligent System Emulation Technology (ISET) Analysis of paracetamol and its impurities Technical Overview Author A.G.Huesgen Agilent
More informationEmulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture
Agilent 129 Infinity II LC with ISET Emulation of the Agilent 11 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture Application Note Small Molecule Pharmaceuticals Author Melanie
More informationPerformance Characteristics of the Agilent 1220 Infinity Gradient LC system
Performance Characteristics of the Agilent 122 Infinity Gradient LC system An integrated LC system for conventional LC and UHPLC Technical Overview 7 5 4 3 2 1.5 1 1.5 2 2.5 3 Introduction The Agilent
More informationAutomated alternating column regeneration on the Agilent 1290 Infinity LC
Automated alternating column regeneration on the Agilent 1290 Infinity LC Increasing throughput using two columns alternatively via an ultra-high pressure 2-position/10-port valve Application Note Environmental
More informationAgilent 1290 Infinity Binary LC System with ISET Emulation of a Waters Alliance 2695 LC Applying Concave, Convex, and Linear Gradients
Agilent 129 Infinity Binary LC System with ISET Emulation of a Waters Alliance 269 LC Applying Concave, Convex, and Linear Gradients Technical Overview Author A.G. Huesgen Agilent Technologies Inc. Waldbronn,
More informationApplication Note. Authors. Abstract. Introduction. Pharmaceutical
Scalability of Agilent s Across HPLC and UHPLC Instruments Application Note Pharmaceutical Authors Anne E. Mack, William J. Long Agilent Technologies, Inc. 2850 Centerville Road, Wilmington, DE 19808 USA
More informationApplication Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau
Development, validation, and comparison of an HPLC method to analyze paracetamol and related impurities according to the European Pharmacopoeia (EP) and USP using the Agilent 1120 Compact LC and the Agilent
More informationAgilent 1290 Infinity Quaternary LC Support of Columns with 2.1 to 4.6 mm ID to 1200 bar
Agilent 129 Infinity Quaternary LC Support of Columns with 2.1 to 4.6 mm ID to 1 bar Technical Overview Authors A.G.Huesgen, Bettina Schuhn Agilent Technologies, Inc. Waldbronn, Germany Abstract Modern
More informationAutomated Scouting of Stationary and Mobile Phases Using the Agilent 1290 Infinity II Method Development Solution
Automated Scouting of Stationary and Mobile Phases Using the Agilent 129 Infinity II Method Development Solution Technical Overview Authors Edgar Naegele and Sonja Schneider Agilent Technologies, Inc.
More informationAgilent 1290 Infinity LC with ISET under Waters Empower control Emulation of Agilent 1100 Series LC
Agilent 1290 Infinity LC with ISET under Waters Empower control Emulation of Agilent 1100 Series LC Technical Overview Author A. G. Huesgen Agilent Technologies, Inc. Waldbronn, Germany Abstract The Agilent
More informationDetermination of Asarinin in Xixin (Asari Radix Et Rhizoma)
Deteration of Asarinin in Xixin (Asari Radix Et Rhizoma) Using Agilent InfinityLab Poroshell 2 EC-C8,.9 µm Columns Application Note Pharmaceutical Author Rongjie Fu Agilent Technologies Shanghai Abstract
More informationApplication Note. Author. Abstract. Pharmaceuticals. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany
Seamless instrument to instrument method transfer of an USP/EP method from an Agilent 1220 Infinity LC to an Agilent 1290 Infinity Binary LC using Intelligent System Emulation Technology (ISET) Application
More informationPractical Applications of Method Translation Using the Agilent Method Translation Tool. eseminar and Workshop
Practical Applications of Method Translation Using the Agilent Method Translation Tool eseminar and Workshop Thomas J. Waeghe, Ph.D. Inside Application Engineer Agilent Technologies Life Sciences and Chemical
More informationApplication Note. Environmental. Agilent 1290 Infinity Binary LC. with ISET and fine-tuning. Agilent 1290 Infinity Binary LC.
Seamless instrument-to-instrument method transfer of the EPA method 833A/B for nitroaromatics from an Agilent 12 Series LC to the Agilent 129 Infinity Binary LC using ISET Application Note Environmental
More informationQuality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC
Quality-by-Design-Based Method Development Using an Agilent 129 Infinity II LC An Efficient Method Development Workflow Combined with ISET-mediated Method Transfer Under Waters Empower 3 CDS Control Application
More informationMethod Translation in Liquid Chromatography
Method Translation in Liquid Chromatography Technical Overview Abstract Ronald E. Majors Agilent Technologies, Inc. 2850 Centerville Rd Wilmington, DE 19808 USA With the recent emphasis on high performance
More informationISET. Agilent 1290 Infinity Binary LC with ISET, emulation of the Waters Alliance 2695 LC system analyzing aromatic acids. Application Note.
Agilent 129 Infinity Binary LC with ISET, emulation of the Waters Alliance 2695 LC system analyzing aromatic s Application Note Food Testing & Agriculture Author A.G.Huesgen Agilent Technologies, Inc.
More informationAgilent 1290 Infinity II LC SET NEW BENCHMARKS IN EFFICIENCY WITH THE NEXT GENERATION OF UHPLC
1290 Agilent 1290 Infinity II LC SET NEW BENCHMARKS IN EFFICIENCY WITH THE NEXT GENERATION OF UHPLC AGILENT 1290 INFINITY II LC NEW BENCHMARKS IN EFFICIENCY The Agilent 1290 Infinity II LC embodies the
More informationTechnical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany
New Features of the Agilent Method Scouting Wizard for Automated Method Development of Complex Samples Analysis of Large Data Sets by Method Scouting Reports and Automated Adjustment of Flow Rates and
More informationACQUITY Arc TM System
ACQUITY Arc TM System Introducing the Newest Member of the Waters LC Portfolio 2015 Waters Corporation 1 Adopting Modern LC Technology in a Global Economy Highly competitive, regulated business environment
More informationAnalysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector
Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector Application Note Clinical Research Author Patrick Cronan Agilent Technologies,
More informationComparing gradient transfer of isocratic hold and delay volume addition using the Agilent 1290 Infinity LC with ISET
Comparing gradient transfer of isocratic hold and delay volume addition using the Agilent 1290 Infinity LC with ISET Technical Overview 180 Red 1290 Infinity LC with isocratic hold of 1 ute Blue 1 Series
More informationMethod Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC
Method Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC Proof of Equivalency for the Analysis of Local Anesthetics Application Note Small Molecule Pharmaceuticals Author Sonja
More informationeasy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.
easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success. Introducing the Agilent 1120 Compact LC Simply a better value. Is your lab looking for better, more reproducible results
More informationPerformance characteristics of the Agilent 1100 Series capillary LC system using diode-array UV and MS for detection. Technical Note.
Performance characteristics of the Agilent 11 Series capillary LC system using diode-array UV and MS for detection Technical Note Abstract This application has been verified using an Agilent 1 Series LC
More informationReducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies
Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies Alternating Column Regeneration Using an Agilent 1200 Infinity Series Quick-Change Bio-inert 2-position/10 port Valve Application
More informationAgilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers
Agilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers Application Note mau Author A. G. Huesgen Agilent Technologies, Inc. Waldbronn, Germany
More informationAgilent 1290 Infinity II LC MORE EFFICIENCY MORE FREE TIME. #EfficientUHPLC
Agilent 1290 Infinity II LC MORE EFFICIENCY MORE FREE TIME #EfficientUHPLC AGILENT 1290 INFINITY II LC NEW BENCHMARKS IN EFFICIENCY The new Agilent 1290 Infinity II LC System embodies the next generation
More informationSeamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC
Seamless Method Transfer from an Agilent 1 Infinity Bio-inert LC to an Agilent 1 Infinity II Bio-inert LC Charge Variant Analysis of Rituximab Innovator and Biosimilar Application Note Biologics & Biosimilars
More informationFast Method Development Using the Agilent 1290 Infinity Quaternary LC System with Column Selection Valve
Fast Method Development Using the Agilent 19 Infinity Quaternary LC System with Column Selection Valve Technical Overview Authors A.G.Huesgen and Bettina Schuhn Agilent Technologies, Inc. Waldbronn, Germany
More informationScale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system
Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system Technical Overview Author Absorbance Monitored wavelength: 230 nm Methylparaben Ethylparaben 9.717
More informationApplication Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany
Method Transfer from an Agilent 1100 Series Quaternary LC to an Agilent 1260 Infinity II LC Proof of Equivalency for the Analysis of Antihistaminic Drugs Application Note Small Molecule Pharmaceuticals
More informationAgilent 1260 Infinity Bio-inert Quaternary LC
Agilent 1260 Infinity Bio-inert Quaternary LC Features, Technical Details, Applications and Infinity Bio-inert Quaternary LC The Agilent 1260 Infinity Bio-inert Quaternary LC system is a dedicated solution
More informationApplication Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany
Quantification of trace-level herbicides in drinking water by online enrichment with the Agilent Infinity Series Online-SPE Solution and Triple Quadrupole MS Detection Application Note Environmental Author
More informationMethod Transfer from an Agilent 1260 Infinity LC to an Agilent 1260 Infinity II LC
Method Transfer from an Agilent 1260 Infinity LC to an Agilent 1260 Infinity II LC Proof of Equivalency for the Analysis of Beta-Blockers Application Note Small Molecule Pharmaceuticals Author Sonja Krieger
More informationAgilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD
1220 Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD AGILENT 1220 INFINITY II LC AFFORDABLE EFFICIENCY WITH CONFIDENCE Take a close look at the Agilent
More informationDisulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column
Disulfide Linkage Analysis of IgG1 using an Agilent 126 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column Application Note Biotherapeutics & Biosimilars Author M. Sundaram
More informationFast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns
Fast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns Application Note Environmental Authors William J. Long and Anne E. Mack Agilent Technologies, Inc. 2850 Centerville Road
More informationAgilent 1290 Infinity II 2D-LC Solution Biopharmaceutical Polymer Analysis. WCBP Jan 2017 Washington, DC
Agilent 1290 Infinity II 2D-LC Solution Biopharmaceutical Polymer Analysis WCBP Jan 2017 Washington, DC 1 Overview Resolving power and how to measure it Why two-dimensional LC? Setup of a 2D-LC System
More informationCharge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs
Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs Application Note Author Suresh Babu C.V. Agilent Technologies India Pvt. Ltd, Bangalore, India Abstract This Application Note describes
More informationSimplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System
Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System Paula Hong, Richard Andrews, Peyton C. Beals, and Patricia R. McConville Waters Corporation,
More informationFast, Low Pressure Analysis of Food and Beverage Additives Using a Superficially Porous Agilent Poroshell 120 EC-C18 Column
Fast, Low Pressure Analysis of Food and Beverage Additives Using a Superficially Porous Agilent Poroshell 12 EC-C18 Column Application ote Food and Beverage Authors Anne E. Mack and William J. Long Agilent
More informationHigh-Throughput LC/MS Purification of Pharmaceutical Impurities
High-Throughput LC/MS Purification of Pharmaceutical Impurities Application Note Small Molecule Pharmaceuticals Author Florian Rieck Agilent Technologies, Inc. Waldbronn, Germany Abstract Legal regulations
More informationHigh-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography
High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography Agilent 1260 Infinity Bio-inert Quaternary LC System with Agilent Bio Columns
More informationAgilent Max-Light Cartridge Cell Information for G4212A and G4212B DAD
Agilent Max-Light Cartridge Cell Information for G4212A and G4212B DAD Information about the Max-Light Cartridge Cells 2 Specifications 2 Description of the dispersion volume V( ) of 2 Recommendations
More informationInfinitely better. Agilent 1200 Infinity Series. Infinity LC. Infinity LC. Infinity LC. products applications soft ware services
Agilent 12 Infinity Series Infinitely better 122 Infinity LC 126 Infinity LC 129 Infinity LC products applications soft ware services Our measure is your success. Agilent 12 Infinity Series Infinitely
More informationA Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies
A Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies Combining Size Exclusion Chromatography with Method Development and Light Scattering Application Note Biotherapeutics and Biosimilars
More informationSize Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column
Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column Application Note Bio-Pharmaceutical Authors M. Sundaram Palaniswamy and Andrew Coffey Agilent Technologies,
More informationTransferring a Method from a Conventional 3.5 µm or 5 µm to an Agilent Poroshell 120 Column to Improve Analytical Speed and Resolution
Video Notes Transferring a Method from a Conventional 3.5 µm or 5 µm to an Agilent Poroshell 120 Column to Improve Analytical Speed and Resolution Ron Majors is Senior Scientist for Agilent s Columns and
More informationAgilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP
Agilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP AGILENT PREP COLUMNS FOR HPLC FLEXIBLE, COST-EFFECTIVE OPTIONS FOR SCALING AND PREPARATIVE
More informationTechnical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany
Using the Agilent Instrument Control Framework to control the Agilent 1290 Infinity LC through Waters Empower software Instrument set up and performance Technical Overview Author A.G.Huesgen Agilent Technologies,
More informationConfident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions
Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions Screening and Confirmation Chemical Analysis Solution Unit November, 2009 Page 1 Agilent s New 6540 Ultra High
More informationAnalytical HPLC solutions
Analytical HPLC solutions that revolve around your needs Agilent 1200 Series HPLC Systems and Modules Our measure is your success. products applications software services Agilent 1200 Series HPLC Flexible,
More informationQuantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS
Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 12 Series RRLC and 641B Triple Quadrupole LC/MS Application Note Manufacturing Process Development Author Siji Joseph Agilent
More informationACQUITY UPLC. I-Class PLUS WHAT SEPARATES YOU FROM EVERYONE ELSE
ACQUITY UPLC I-Class PLUS WHAT SEPARATES YOU FROM EVERYONE ELSE COMPLEX CHALLENGES SOLVED Looking for answers to the most complex scientific challenges is what you do. Your research could lead to ground-breaking
More informationDeveloping Quantitative UPLC Assays with UV
Developing Quantitative UPLC Assays with UV Detection for Antibodies & Other Proteins Steve Taylor 2011 Waters Corporation 1 Outline UPLC technology for RP protein separations Method development parameters
More informationACQUITY Arc VERSATILITY WITHOUT COMPROMISE
ACQUITY Arc VERSATILITY WITHOUT COMPROMISE BUILT UPON A FOUNDATION OF RELIABILITY With the ACQUITY Arc System, analytical scientists can experience true plug-and-play method compatibility for HPLC and
More informationAgilent 1260 Infinity II Prime LC ACHIEVE CONVENIENCE EVERY DAY IN EVERY WAY
1260 Agilent 1260 Infinity II Prime LC ACHIEVE CONVENIENCE EVERY DAY IN EVERY WAY AGILENT 1260 INFINITY II PRIME LC ACHIEVE CONVENIENCE AND EFFICIENCY EVERY DAY IN EVERY WAY The Agilent 1260 Infinity II
More informationAnalysis of amoxicillin and five impurities on the Agilent 1220 Infinity LC System
Analysis of amoxicillin and five impurities on the Agilent Infinity LC System LC analysis of impurities down to the.% level with long sub--µm columns, high flow rates and back pressure greater than bar
More informationAgilent LC and LC/MS Purification Solutions. Purify your way
Agilent LC and LC/MS Purification Solutions Purify your way AGILENT LC PURIFICATION SOLUTIONS PURIFY YOUR WAY WITH PURELY BETTER SOLUTIONS FOR COMPOUND ISOLATION Agilent Technologies offers the most comprehensive
More informationDeveloping Purification Strategies for the Agilent 1260 Infinity II Preparative LC/MSD System
Developing Purification Strategies for the Agilent 126 Infinity II Preparative LC/MSD System Technical Overview Author Florian Rieck Agilent Technologies, Inc. Waldbronn, Germany Abstract Peak-based fraction
More informationApplication Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider
Combining small-scale purification and analysis of monoclonal antibodies on one instrument Protein purification with high-volume injection using the Agilent 126 Infinity Bio-inert Quaternary LC System
More informationAgilent SD-1 Purification System. Purify your way SD-1
Agilent SD-1 Purification System Purify your way SD-1 AGILENT SD-1 PURIFICATION SYSTEM PURIFY YOUR WAY WITH HIGH QUALITY SEPARATIONS AT ANY SCALE The Agilent SD-1 Purification System achieves better gradient
More informationAnalysis of TCM injections using the Agilent 1290 Infinity LC system
Analysis of TCM injections using the Agilent 1290 Infinity LC system Application Note Traditional Chinese Medicine Authors Zhixiu Xu Agilent Technologies Shanghai Shanghai 200131 China mau 400 350 300
More informationClone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution
Clone Selection Using the Agilent 9 Infinity Online D-LC/MS Solution Application Note Biopharmaceuticals Authors Abstract Ravindra Gudihal and This Application Note describes the Agilent 9 Infinity online
More informationRobustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety
Technical Overview Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety Authors Mark Sartain, Theresa Sosienski, and Dan Hui Dorothy Yang Agilent Technologies, Inc.
More informationADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS
Agilent AdvanceBio Columns ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS with Agilent ZORBAX RRHD 3Å 1.8 µm columns ns Rapid resolution high definition columns for UHPLC protein and peptide separations
More informationAdvanceBio Peptide Mapping
AdvanceBio Peptide Mapping An HPLC Column Technology for Faster Protein Biocharacterizations Tim Rice BioColumn Technical Specialist 1 What Is Peptide Mapping? The chemical or enzymatic treatment of a
More informationApplication Note. Author. Abstract. Small Molecule Pharmaceuticals & Generics. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany
Analysis of Degradation Products of Doxycycline in Solution Exposed to Light and Elevated Temperatures Using the Agilent 1 Infinity Series High Dynamic Range Diode Array Detector Impurity Analyzer System
More informationAgilent 1260 Infinity Bio-inert Quaternary LC System. Infinitely better for bio-molecule analysis
Agilent 0 Infinity Bio-inert Quaternary LC System Infinitely better for bio-molecule analysis AGILENT 0 INFINITY BIO-INERT LC INFINITELY BETTER FOR BIO-MOLECULE ANALYSIS The Agilent 0 Infinity Bio-inert
More informationProtein Separation with ph Gradients Using Composite Buffer Systems Calculated by the Agilent Buffer Advisor Software
Protein Separation with ph Gradients Using Composite Buffer Systems Calculated by the Agilent Buffer Advisor Software Technical Overview. Author Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany
More informationAgilent 218 Purification System. Purify your way
Agilent 218 Purification System Purify your way 218 AGILENT 218 PURIFICATION SYSTEM PURIFY YOUR WAY WITH A FLEXIBLE SYSTEM WITHIN REACH OF YOUR BUDGET The Agilent 218 Purification System has the flexibility
More informationBioHPLC columns. Tim Rice Biocolumn Technical Specialist
BioHPLC columns Tim Rice Biocolumn Technical Specialist AU Typical Application Areas Size Exclusion: Aggregation Analysis Ion Exchange: Charge Isoform Analysis 0.035 Monomer 0.030 0.025 0.020 0.015 Dimer
More informationAgilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility
Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility Technical Overview Introduction Agilent AdvanceBio SEC columns are a new family of size exclusion chromatography (SEC) columns
More informationGradient Elution. Slide 2
Gradient Elution Why choose this separation mode? What HPLC parameters affect a gradient separation? How can I use these parameters to improve my gradient separation? Slide 2 Is Gradient or Isocratic Elution
More informationSeparation Science Built for Biopharma
Separation Science Built for Biopharma Pharma & Biopharma Tours 2016 The world leader in serving science Overview 1. Evolution of UHPLC built for biopharma Meet the family 2. What makes Vanquish different?
More informationControlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.
Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software Technical Overview Abstract The Waters Empower 2 chromatography data software with ICS 1.05
More informationultra why micro-lc? product note introducing the ExpressLC -Ultra system: UHPLC with all the advantages of micro-lc
product note introducing the ExpressLC -Ultra system: UHPLC with all the advantages of micro-lc With the new ExpressLC-Ultra, Eksigent offers an LC system that delivers all the advantages of micro-lc at
More informationPeptide Mapping: A Quality by Design (QbD) Approach
Peptide Mapping: A Quality by Design (QbD) Approach Application Note Bio-Pharmaceutical Authors Sreelakshmy Menon and Suresh babu C.V. Agilent Technologies, Inc. Richard Verseput S-Matrix Corporation Abstract
More informationAgilent 1260 Infinity LC & LC/MS Purification Systems. Purify your way
Agilent 1260 Infinity LC & LC/MS Purification Systems Purify your way 1260 AGILENT 1260 INFINITY LC & LC/MS PURIFICATION SYSTEMS PURIFY YOUR WAY WITH MAXIMUM PURITY AND RECOVERY Agilent 1260 Infinity LC
More informationMinimize Method Development Time for Pesticide Screening Using LC/MS Application Kit
Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit Dr. Jerry Zweigenbaum Senior Applications Scientist Food Safety Page 1 Agilent 1260 LC SampliQ Extraction and Dispersive
More informationAdvancedTools in HPLC methoddevelopment
AdvancedTools in HPLC methoddevelopment Remco Stol, Enrico Martina and Jeffrey Vos Analytical Sciences Chemistry, Quality Unit API/BT NL FHI symposium, Houten, 22 april 2010 What does the customer want?
More informationGAIN GREATER CONFIDENCE AGILENT SOLUTIONS FOR QUALITY-BY-DESIGN IMPLEMENTATION IN PHARMACEUTICAL DEVELOPMENT
GAIN GREATER CONFIDENCE AGILENT SOLUTIONS FOR QUALITY-BY-DESIGN IMPLEMENTATION IN PHARMACEUTICAL DEVELOPMENT Primer CONTENTS INTRODUCTION: AN OVERVIEW OF QUALITY BY DESIGN...3 ELIMINATING VARIABILITY IN
More informationQualification of High-Performance Liquid Chromatography Systems
Qualification of High-Performance Liquid Chromatography Systems L. Huber Hewlett- Packard GmbH, Waldbronn December 1998 Manuscript of an article published in BioPharm, Vol 11 Number 11, November 1998,
More informationAgilent 1260 Infinity II LC ASPIRE TO NEW LEVELS OF EFFICIENCY EVERY DAY IN EVERY WAY
1260 Agilent 1260 Infinity II LC ASPIRE TO NEW LEVELS OF EFFICIENCY EVERY DAY IN EVERY WAY AGILENT 1260 INFINITY II LC EVERYDAY EFFICIENCY WITH CONFIDENCE Put your trust in the LC platform that runs, and
More informationUnderstanding the Effects of Common Mobile Phase Additives on the Performance of Size Exclusion Chromatography
Understanding the Effects of Common Mobile Phase Additives on the Performance of Size Exclusion Chromatography 1 Presentation Importance of aggregate analysis in BioPharma manufacturing Analytical techniques
More informationAuthors. Introduction. Experimental. Environmental Analysis
Determination of Phenyl Urea and Triazine Herbicides in Potable and Groundwater by LC/MS Using API-ESI Selective Ion Monitoring and Direct Large-Volume Aqueous Injection Application Environmental Analysis
More informationReversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 300SB-C8 1.
Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 3SB-C8 1.8 µm Column Application Note Biopharmaceuticals Authors James Martosella and Phu
More informationEPA 8330A Analysis of Explosives Using Agilent Poroshell 120 EC-CN and EC-C18 Columns
EPA A Analysis of Explosives Using Agilent Poroshell EC-CN and EC-C Columns Application Note Environmental Author Anne Mack Agilent Technologies, Inc. Abstract A group of nitroaromatics and nitraes was
More informationSeparate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC
Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC The Agilent 126 Infinity Bio-Inert Quaternary LC System and the AdvanceBio SEC 3Å, 2.7 µm Column Application Note Biologics
More informationImproved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD)
Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD) Technical Overview Author Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany Abstract This Technical
More informationImproved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental
Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental Samples Michael S.Young, Jeremy C. Shia, Kim vantran, Kevin M. Jenkins and Masayo Yabo Waters Corporation 34 Maple Street,
More informationAutomated QbD-Based Method Development and Validation of Oxidative Degraded Atorvastatin
Automated QbD-Based Method Development and Validation of Oxidative Degraded Atorvastatin Application Note Pharmaceutical QA/QC Authors Vinayak AK and Syed Salman Lateef Agilent Technologies Inc, Bangalore,
More informationFraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System
Application Note Biologics & Biosimilars Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction Chromatography Agilent 126 Infinity II Bio-Inert System 7 6 5 4 5. 7.5
More informationIntroduction Ron Majors is a Senior Scientist at Agilent. Bill Champion is a chemist in Agilent s HPLC Columns tech support group.
Video Notes LC Troubleshooting Series Ghost Peaks Introduction Ron Majors is a Senior Scientist at Agilent. Bill Champion is a chemist in Agilent s HPLC Columns tech support group. Ghost peaks can come
More informationAgilent 1260 Infinity Bio-inert Quaternary LC