RAJESH NAIR DIRECTOR CALF-NDDB, ANAND, GUJARAT

Size: px
Start display at page:

Download "RAJESH NAIR DIRECTOR CALF-NDDB, ANAND, GUJARAT"

Transcription

1 RAJESH NAIR DIRECTOR CALF-NDDB, ANAND, GUJARAT 1

2 Coverage Need of AQC in food testing laboratories Analytical quality system of food testing laboratories Relationship between Quality System, Quality Assurance & Quality Control Variables of data accuracy Analytical Quality Control (AQC)in food testing laboratories ISO/IEC 17025:2005: Concepts Internal quality control checks External quality control checks Trend Analysis using control charts Conclusion 2

3 Need of AQC in food testing laboratories Emerging food safety issues such as presence of microbial pathogens, bacteria, viruses, environmental toxins, allergens, adulterants, residues of agricultural drugs and toxic chemicals in food commodities, increased consumer awareness and rapidly growing international trade in food have stimulated the demand for accurate food safety testing all over the world. Information about the quality of the food commodity can be generated through quality testing in analytical laboratories. Analytical quality control, commonly shortened to AQC refers to all those processes and procedures designed to ensure that the results of laboratory analysis are consistent, comparable, accurate and within specified limits of precision. 3

4 Analytical quality system of food testing laboratories Quality is hard to define in a way that is appropriate for all situations Therefore, quality means that the laboratory results meet the customer s expectations and are accurate and defensible Analytical quality system of a food testing laboratory includes Quality assurance which further includes quality control. The meaning of the terms Quality Control and Quality Assurance(QA) often vary according to the context In practical terms, QA relates to the overall measures taken by the laboratory to regulate quality Whereas quality control describes the individual measures which relate to the quality of individual samples or batches of samples. 4

5 Relationship between Quality System, Quality Assurance & Quality Control Quality System Quality Assurance Quality Control Quality management works on the organizational level to implement an overall quality policy. A quality system refers to the organizational resources, processes and procedures to implement quality management, which is broader than both Quality Assurance (QA) and Quality Control(QC). QA program is the backbone of the laboratory quality system. QA provides a management tool within the organization. QC is a process within the QA program. The process is to collect evidence that the desired level of quality is achieved. 5

6 Variables of data accuracy Analytical variables Post analytical variables Preanalytical variables 6

7 Analytical Quality Variables PREANALYTICAL Laboratory facilities Laboratory facilities Design of the laboratory Environmental control Housekeeping control Staffing and organization Management structure Job description Staff training Staff performance Support personnel Analytical Standard material & Equipment Shelf life and storage Classes of equipment Maintainenance, calibration and repair Sample collection and handling Sampling Transportation Test material identification Control and storage Methods of analysis Selection method Validation of analytical methods Quality control procedures Quality assurance procedures Chemicals, reagent and standards POST ANALYTICAL External proficiency testing Maintenance of laboratory records Statistical Quality Control 7

8 Laboratory facilities Analytical Quality Variables Facilities must allow Laboratories work to proceed both effectively and safely Facilities should reflect the general features of work programme in long term rather than the specific pattern of current work Design of the laboratories Laboratory should be designed with efficiency in mind Even though the final design of the laboratory is made by architects and engineers the technical hand should be involved in establishing food control laboratories Design of the laboratory should meet minimum requirements to perform several functions such as chemical analysis of foods for proximate, trace metals, additive, nutrients residues and contaminants and for some basic food microbiology as well Environmental control Adequate control of temperature, humidity, and dust is important for staff comfort, instrumental performance and safe working(e.g. with flammable solvents) Computers need to be protected from strong magnetic fields Direct exposure of chemicals and reagents to sunlight and fluorescent light must be avoided Delicate balances and optical instruments may need to be protected from vibrations All these needs have to be documented and identified 8

9 Sampling Analytical Quality Variables Analytical data reported must reflect the composition of received samples as a whole Test material identification Without clear and unambiguous receipt and identification of each individual sample, quality assurance can not be maintained Each test material must be given an identification code, which can uniquely identify that material and records of its analysis Control and storage Deterioration of the test material invalidates the test results Therefore test material must be stored, so as to ensure their integrity, safety, legality and stability Equipment Each item of equipment used in the course of work must be known to be in the proper working order An instrument may be used only by staff with appropriate training For each instrument, the nature and frequency of performance checks and the person responsible for should be specified 9

10 SELECTION OF THE METHOD Analytical Quality Variables Any analytical method used on test materials must be followed in accordance with intended purpose of analysis and must have quality control procedure associated with it Reference methods Official methods In- house methods Screening methods Protocols VALIDATION OF THE METHOD Validation is a process of establishing documentary evidence demonstrating that a procedure, process, or activity carried out in production or testing maintains the desired level of compliance at all stages. 10

11 Analytical Quality Variables Initial Validations Methods must first undergo in-house validation and quality assurance programme which specify what parameters to include in validation Validation of a method developed in house must additionally identify factors which are revealed by an inter laboratory trial Thus it will include demonstration of the robustness of the method and identification of anyaspectofthemethodwhicharecriticaltoitsabilitytogenerateaccuratedata On going validation Some form of ongoing check that the method is continuing to work properly is necessary The nature and frequency of these checks need to reflect the complexity of the method, the degree of skills required, its reliability, track record, number of samples analysed and the quality of data required Usually the checks will take the form of some or all quality control procedures 11

12 Analytical Quality Control (AQC) in food testing laboratories Quality Control refers to a measuring process, or to check a result and provide assurance that all activities are performing within predetermined limits. Why QC? Safety of the consumer is being ensured through quality testing of food commodity in analytical laboratories. What is the goal? To check that the results being produced are fit for purpose. Rapid detection of SIGNIFICANT errors Provide accurate results in a timely manner Cost effective and simple to use To identify the source of error 12

13 ISO/IEC 17025:2005: General requirements for the competence of testing and calibration laboratories 4. Management Requirements 1. Organization 2. Management System 3. Document Control 4. Review of requests, tenders and contracts 5. Subcontracting of tests and calibrations 6. Purchasing services and supplies 7. Service to the customer 8. Complaints 9. Control of nonconforming testing and/or calibration work 10. Improvement 11. Corrective action 12. Preventive action 13. Control of records 14. Internal audits 15. Management reviews 5. Technical Requirements 1. General 2. Personnel 3. Accommodation & environmental conditions 4. Test & calibration methods & method validation 5. Equipment 6. Measurement Traceability 7. Sampling 8. Handling of test & calibration items 9. Assuring the quality of test & calibration results(5.9.1) 10. Reporting the results 13

14 ISO Clause says... The laboratory shall have quality control procedures for monitoring the validity of tests and calibrations undertaken. The resulting data shall be recorded in such a way that trends are detectable and, where practicable, statistical techniques shall be applied to the reviewing of the results. This monitoring shall be planned and reviewed and may include, but not be limited to, the following a. UseofCRMsand/orRMs; b. Proficiency-testing; c. Replicate tests; d. Retesting; e. Correlation of results for different characteristics 14

15 Quality control checks in daily life 15

16 Classification of AQC Internal Quality Control External Quality Control 16

17 Internal quality control checks Internal quality control consists of all the procedures undertaken by a laboratory for the continuous evaluation of its work in order to ensure the consistency of day-to-day results and their conformity with defined criteria Thismaytakeavarietyofformsincludingtheuseof 1. Replicate determinations 2. Reagent blank 3. Method blank 4. Solvent blank 5. Positive control 6. Negative control 7. Use of in-house standards 8. Use of internal standards 9. Use of certified reference material 10. Spike recovery 11. Retesting/Blind sample 12. Calibration verification 13. Trend analysis using control charts 17

18 Replicate determinations Conducting repeat analysis of the same sample Where results are customarily reported on the basis of single determination, it should be practice to include in an analytical batch replicate determinations on the same test material Preferably Replicate of the same test material should be randomised in batch and ideally the analyst should not be aware of their presence 18

19 Blank/Reagent Blank/ Method Blank/ Solvent Blank Ablankormethodblankdetermination isananalysisofasamplewithoutthe analyteor attribute, or an analysis without a sample, i.e. going through all steps of the procedure with the reagents only It is used to determine the contribution of the reagents and the preparative analytical steps to error in the measurement For convenience, some analysts practice "forcing the blank to zero" by adjusting the instrument. Some instruments even invite or compel analysts to do so This is equivalent to subtracting the blank value from the values of the standards before plotting the calibration graph From the standpoint of Quality Control this practice must be discouraged This is becoming more and more common practice with modem sophisticated hi-tech instruments Whateverthecase,adecisiononhowtodealwithblanksmustmadeforeachprocedure andlaiddowninthesopconcerned 19

20 Positive control Where it is anticipated that the majority of the test portion will not contain significant amounts of analyte, it is important to analyse test portion to which analyte has been added and show that the analysis produces expected results This approach can be used to check the effectiveness of the screening test or in presence or absence analysis It is useful for checking the ability to correctly identify test portions containing analyte at the action level Itcanbeusedtoassestheincidencesoffalsenegatives This practice can be proved to be more useful in nutritional analysis of a product claimed to be fortified with the respective nutrients 20

21 Negative control In a reverse situation of positive control where, most test portion contains significant amount of analyte, it is important to include number of test portions which are essentially free of the analyte so as to provide confidence that laboratory contamination levels are acceptably low Use of a matrix which is essentially free of the analyte is particularly important in analysis for trace amounts of additives In case of residues and contaminants it is preferred to have reagent blanks, which contain no test matrix The other form of negative control uses test materials known to contain analyte at levels just below the action level, results from these provide a check on the incidence of false positive 21

22 In-house standards When a large number of similar analysis are to be conducted over a period of time it is usefultochecktheselfconsistencyofthedatabyuseofaninhousestandardmaterial For this a relatively large amount of the matrix containing an appropriate level, it can be homogenised and kept under conditions where the analyte is stable At specified intervals test portions from this in-house standards are included in a normal analytical batch Over a period of time it is possible to see whether the method is giving consistent data andtoobtainanestimateofthelongtermprecision A large number of repeat analysis conducted on the in-house standard over a short time allow the in-house precision(repeatability) of the method to be calculated 22

23 Internal standards Internal standards are similar in analytical behaviour to the compounds of interest, and notexpectedtobefoundinthesamples The response of the target compound is normalized to the response of the reference standard. This reference standard is called an internal standard because it is contained within the aliquot of the sample or sample extract that is actually injected into the instrumentation The ratio of the peak area (or height) of the target compound in the sample or sample extract to the peak area (or height) of the internal standard in the sample or sample extract is compared to a similar ratio derived for each calibration standard The analyst needs to demonstrate that the measurement of the internal standard is not affected by target analytes, surrogates or by matrix interferences This is not as useful for GC and HPLC methods with non-ms detectors, unless the internal standards could be separated from target compounds chromatographically The retention times of the target compound and the internal standard may be used to calculate the relative retention time (RRT) of the target compound and can then be used to compensate for small retention time shifts 23

24 Use of Certified Reference Material These are homogenous test materials in which the analyte has been determined with great care usually by a number of expert laboratories and preferably using a number of different analytical techniques By analysing appropriate certified reference material from time to time it is possible to check the accuracy of the results The in-house standards demonstrates the precision (consistency) of the data being produced while CRM demonstrates the accuracy i.e. how near the results are to correct values Since most analytical instrumentation is comparative, it requires a sample of known composition (reference material) for accurate calibration. These reference materials are produced under stringent manufacturing procedures and differ from laboratory reagents in their certification and the traceability of the data provided. Quality management system involving laboratory accreditation as per ISO/IEC requires metrological traceability to Certified Reference Materials (where possible) when using reference materials for calibration 24

25 Spike Recovery Spike, recovery is an important method for assessing the accuracy of analytical techniques for particular sample types Matrix match standards are ideal for residue testing to get a better recovery Spike-and-recovery is used to determine whether analyte detection is affected by a difference between the diluent, dilution accuracy of calibration standards prepared, the standard curve and the sample matrix Recovery shall be determined in each batch of samples and the recovery factor obtained for the specific batch shall be used in quantitative determination of an analyte in sample Standard recovery criteria are as given in the table, again it depends on respective regulations. concentration Accepted recovery range Less than 1 µg/kg -50 to +20 Between 1 to 10 µg/kg -30 to +10 More than 10 µg/kg -20 to +10 Calibration curve should include at least five calibration points and the working range should be clearly described 25

26 Retesting /Blind sample Retesting of retained sample The stable parameters to be considered as the storage may adversely affect the result The variation should be recorded and investigated OneofthecommonlyfollowedQCinfoodlabs. 26

27 Calibration verification Calibration is the process of testing and adjusting an instrument, kit, or test system readout to establish a correlation between the instrument s measurement of the substance being tested and the actual concentration of the substance Use of CCV standards are recommended in heavy metal testing Calibration verification is the periodic confirmation by analysis of a calibration standard that the instrument performance has not changed significantly from the initial calibration Calibration verification should also be performed under the following conditions 1. Whenever major maintenance is performed or a critical component part of an analyser has been replaced 2. Whenever reagent lots are completely changed (unless it has been stated and shown that these lot changes do not affect test results, as with manufacturer s instructions and guidelines in package inserts and analyser specific manuals) 3. When control values are found to be continually unacceptable, as with shifts and trends in Shewharts/Levy-Jennings graphs over a period of time 27

28 AQC checks in Food Microbiology Lab Standards & critical consumable checks Reference culture quality checks Critical consumable quality verification Media/Diluent sterility checks Spiking samples with reference microbial cultures Duplicate analysis of sample for enumeration tests Analysis of same sample by different method, personnel, equipment etc. 28

29 External quality control Laboratories may wish for, or indeed may be required to have, an external check on their performance. For this, they need to participate in Proficiency testing(pt) schemes. Example of EQC includes 1. Inter laboratory comparisons 2. Proficiency Testing Inter laboratory comparison It is inter comparison of measurement results of a laboratory Successful participation in an inter laboratory comparison is one of the necessary requirements of quality control of data generated from food testing laboratories when PT is not available. 29

30 External quality control Proficiency testing External proficiency testing is an independent external assessment of the correctness of the results and provides an impartial test of analytical quality: which can be done through an inter laboratory proficiency testing Usually it involves presenting the analyst with the test material and requesting specific information about its properties such as moisture, fat, protein, ash, fatty acid composition, toxic metal concentration, pesticide/drug residues etc. Ideallytheanalystshouldnotbeawarethattheitisproficiencytest,butoftenthiswillnot be feasible Asinglebadresultfrombadtestingmaypromptactionstorectifythematter,butasingle good result in no way guarantees that all results are of quality achieved on the proficiency testing The proficiency test therefore needs to be conducted on quite regular basis 30

31 Trend Analysis using control charts The control chart, also known as the process-behaviour chart is one of the seven basic tools of Statistical Quality Control A control chart is a graph of test results with respect to time or sequence of measurements, with limits drawn within which results are expected to lie when the analysis is in a state of statistical control. A procedure is in statistical control when results consistently fall within established control limits. It reveals trends that in themselves do not yet result in a rejection of analytical results, but it will give early warnings of issues or problems that are developing. The accuracy of an analysis or manufacturing process is monitored using one or more of the following control charts: Shewhart control chart Moving average control chart CUSUM control chart 31

32 Shewhart Control Charts Valueofthecontrolsample/QCstandardforeachbatchisplottedontheyaxis. The batch number(or measurement number) is plotted on the x axis. If the analysis (or process) is working satisfactorily the points should be randomly distributed about the target value and between the upper warning limit (UWL) and lower warning limit (LWL). Warning limits at the target value±2s (where s is the standard deviation of a large number of replicate analyses) and the action limits at the target value ±3s 32

33 Moving average Control Chart The average results of a given number of batches is plotted, instead of plotting the result for each individual batch. Each point plotted will be the average of that batch, plus a given number of batches immediately before it. Advantage: This smoothens the data making trends easier to see. Disadvantage: This delays the appearance of changes affecting the analysis. The warning limits are the target value±(2s/ n) and the action limits are the target value ±(3s/ n), where n is the number of batches used to calculate the moving average. 33

34 CUSUM Control Chart This chart shows up trends more quickly than a Shewhart chart. In this chart, the difference between each QC value and the target value (QC result target value) is calculated, taking note of the sign. The differences are added and plotted against batch number. If the analysis is working satisfactorily the points will wander about 0(the x axis). If there is a problem with the analysis or process, the points will move away from the x axis,upordown. Target value 34

35 Trend-Out of Control The warning limits can be expected to be breached once in 20 occasions, therefore no action may be required for a single breach when all other points lie within the warning limits and are randomly distributed around the target mean. More fall outside 3s (outside the upper or lower control limits) Two or more consecutive values fall outside 2s (outside the upper or lower warning limits) on the same side of the mean A series of seven or eight consecutive values fall all above or all below the mean An increasing or decreasing trend is detected. 35

36 Conclusion Laboratory accreditation does not guarantee that the laboratory is of high quality, but it helps give customers confidence that the lab is capable of producing quality data. Implementation of the AQC requires resources and investment, so there is a significant cost to quality. By applying systematic and continuous QC tools in routine testing, a lab can achieve the accuracy in their reported results. The new trend includes software programs to implement QC activities and statistical analysis. The responsibility of QC does not lie with only the laboratory management or QC /QA department personnel. Each individual working in the lab is responsible for the implementation of QC techniques. QC is a collective responsibility. 36

37 Thank You For Your Kind Attention

MODULE 2A GENERAL MANAGEMENT SYSTEM REQUIREMENTS

MODULE 2A GENERAL MANAGEMENT SYSTEM REQUIREMENTS MODULE 2A GENERAL MANAGEMENT SYSTEM REQUIREMENTS 2A.1 SCOPE (See ISO/IEC 17025:2005, Section 1) Laboratories shall meet all requirements of the ISO/IEC 17025:2005 International Standard and other AIHA-LAP,

More information

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017 Laboratory Page 1 of 17 Laboratory December 6, 2017 2017 by A2LA All rights reserved. No part of this document may be reproduced in any form or by any means without the prior written permission of A2LA.

More information

ISO General Requirements for Competence of Testing Laboratories Procedure

ISO General Requirements for Competence of Testing Laboratories Procedure Competence of Testing Laboratories Page: 1 of 24 ISO 17025 General Requirements for Competence of Testing Laboratories Procedure Competence of Testing Laboratories Page: 2 of 24 Table of Contents Para.

More information

ISO/IEC 17025:2017 Working Document Instruction Page

ISO/IEC 17025:2017 Working Document Instruction Page Instruction Page NOTES: 1. This working document is intended as a checklist for the assessor when conducting Testing and Calibration Laboratory and Sampling Organization Assessments according to ISO/IEC

More information

Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the

Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the Compost Quality Protocol Renewable Energy Assurance

More information

TECHNICAL REQUIREMENTS (CLAUSE 5)

TECHNICAL REQUIREMENTS (CLAUSE 5) LECTURE 4 THE ELEMENTS OF ISO/IEC 17025 - TECHNICAL REQUIREMENTS (CLAUSE 5) Slide 1 ISO 17025 - RELATIONSHIP OF EACH REQUIREMENTS Management System Organization Quality system Continual Improvement Management

More information

Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the

Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the Compost Quality Protocol Renewable Energy Assurance

More information

The new ISO/IEC 17025:2017

The new ISO/IEC 17025:2017 The new ISO/IEC 17025:2017 By Dr. George Anastasopoulos Director, Conformity assessment, IAS Email: ganastasopoulos@iasonline.org Introduction - Background information ISO/IEC 17025 was first issued in

More information

Control Charts and Trend Analysis for ISO 17025

Control Charts and Trend Analysis for ISO 17025 2015 Webinar Series Control Charts and Trend Analysis for ISO 17025 5/27/2015 Speakers Cynthia Mangione, Microbiology QAO, New York State Department of Agriculture and Markets, Food Laboratory Division,

More information

A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018

A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018 A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018 Laboratory Name: Appendix Name: Appendix Number: Assessor: Date: Rev. 4.1 CALA CHECKLIST FOR MICROBIOLOGY Item 01 SAMPLING AND SAMPLE

More information

ISO and SANAS guidelines for use of reference materials and PT scheme participation. T & M Conference

ISO and SANAS guidelines for use of reference materials and PT scheme participation. T & M Conference ISO 17025 and SANAS guidelines for use of reference materials and PT scheme participation T & M Conference Presentation layout 1. Introduction ISO/IEC 17025 2. Requirements for use Reference Materials

More information

General requirements for the competence of testing and calibration laboratories. In this presentation:

General requirements for the competence of testing and calibration laboratories. In this presentation: General requirements for the competence of testing and calibration laboratories ISO/IEC 17025:2017 In this presentation: Explanation New requirement Interpretation / Examples / Questions Agenda Welcome

More information

How to use the TNI standards to meet essential QC elements in the MUR

How to use the TNI standards to meet essential QC elements in the MUR How to use the TNI standards to meet essential QC elements in the MUR August 7, 2012 Susan Wyatt Minnesota Department of Health EPA Methods Update Rule Finalized on May 18, 2012 (Proposed 9/23/2010) Effective

More information

Medical Cannabis Laboratory Approval Program

Medical Cannabis Laboratory Approval Program Medical Cannabis Laboratory Approval Program APPLICATION PROCESS AND REQUIRED DOCUMENTATION The Medical Cannabis Laboratory Application consists of three-steps to thoroughly assess applying laboratories.

More information

TECHNICAL AND PRODUCTION REQUIREMENTS of ISO Guide 34:2009

TECHNICAL AND PRODUCTION REQUIREMENTS of ISO Guide 34:2009 SANAS Accr. No/s. TECHNICAL AND PRODUCTION REQUIREMENTS of ISO Guide 34:2009 Date/s of evaluation Assessor/s & Observers Facility Area / field of Representative operation This report covers the following:

More information

STATIONARY SOURCE AUDIT SAMPLE PROGRAM [VOLUME 1, MODULE 1] GENERAL REQUIREMENTS FOR STATIONARY SOURCE AUDIT SAMPLE PROVIDERS

STATIONARY SOURCE AUDIT SAMPLE PROGRAM [VOLUME 1, MODULE 1] GENERAL REQUIREMENTS FOR STATIONARY SOURCE AUDIT SAMPLE PROVIDERS [V1M1-2014]-Rev2.0 STATIONARY SOURCE AUDIT SAMPLE PROGRAM [VOLUME 1, MODULE 1] GENERAL REQUIREMENTS FOR STATIONARY SOURCE AUDIT SAMPLE PROVIDERS TNI Working Draft Standard P.O. Box 2439 Weatherford, TX

More information

General Accreditation Guidance. ISO/IEC 17025:2017 Gap analysis. April 2018

General Accreditation Guidance. ISO/IEC 17025:2017 Gap analysis. April 2018 General Accreditation Guidance Gap analysis April 2018 Copyright National Association of Testing Authorities, Australia 2018 This publication is protected by copyright under the Commonwealth of Australia

More information

From purpose based interpretation to appropriate application of Calibration and Interlaboratory comparison results

From purpose based interpretation to appropriate application of Calibration and Interlaboratory comparison results From purpose based interpretation to appropriate application of Calibration and Interlaboratory comparison results Mulugeta Derebew mulugetaderebew@yahoo.com Test & Measurement 2017, Conference and Workshop,

More information

Handbook ISO/IEC 17025:2017

Handbook ISO/IEC 17025:2017 Handbook ISO/IEC 17025:2017 Page 1 of 32 General considerations This new standard ISO/IEC 17025 includes some noteworthy changes related to its structure and scope that should be mentioned before we go

More information

GLP/SC/01 Basic statistical tools for analytical chemistry (2 days)

GLP/SC/01 Basic statistical tools for analytical chemistry (2 days) GLP Consulting http://consultglp.com Courses on offer (See outlines below) GLP/SC/01 Basic statistical tools for analytical chemistry (2 days) GLP/SC/02 The GUM bottom-up evaluation technique of measurement

More information

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals.

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals. Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals. 1 Analytical Method Validation: 1..1 Philosophy: Method validation is

More information

Verification of Method XXXXXX

Verification of Method XXXXXX Reviewed By: Date: Technical Supervisor Reviewed By: Date: General Supervisor Reviewed By: Date: Quality Assurance Coordinator Approved By: Date: Director Page 1 of 11 Table of Contents Purpose and Principle:...

More information

Overview of Good Food Laboratory Practices

Overview of Good Food Laboratory Practices Overview of Good Food Laboratory Practices Dr. Anne Bridges Technical Director, AACC International International Workshop & Training Program On Good Food Laboratory Practices Jointly Organized By Food

More information

Procedure for Equipment Calibration and Maintenance

Procedure for Equipment Calibration and Maintenance Procedure for Equipment Calibration and Maintenance 1.0 Purpose This procedure specifies the schedule and requirements for calibration, performance verification, and maintenance of State Crime Laboratory

More information

CRITICAL ASPECT ANALYTICAL TEST REVIEW

CRITICAL ASPECT ANALYTICAL TEST REVIEW CRITICAL ASPECT ANALYTICAL TEST REVIEW Jakarta 14 December 2017 Speaker: HERU PURNOMO, ST QC WORK FLOW Start Sample Received (In-Process & Finished Good) Testing Review Lab Result Yes No Non Conformance

More information

National Shellfish Sanitation Program (NSSP) Guide for the Control of Molluscan Shellfish: 2017 Revision

National Shellfish Sanitation Program (NSSP) Guide for the Control of Molluscan Shellfish: 2017 Revision PUBLIC HEALTH SERVICE U.S. FOOD AND DRUG ADMINISTRATION OFFICE OF FOOD SAFETY SHELLFISH AND AQUACULTURE POLICY BRANCH 5001 CAMPUS DRIVE COLLEGE PARK, MD 20740-3835 TEL. 240-402-2151/2055/4960 FAX 301-436-2601

More information

TNI s NATIONAL ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM (NELAP) Changing to the 2009 Standard

TNI s NATIONAL ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM (NELAP) Changing to the 2009 Standard TNI s NATIONAL ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM (NELAP) Changing to the 2009 Standard THE NEW NELAP STANDARDS Four Volumes = Four Standards Volume 1: Requirements for Laboratories 7 Modules

More information

ENVIRONMENTAL LABORATORY SECTOR VOLUME 1. Management and Technical Requirements for Laboratories Performing Environmental Analysis.

ENVIRONMENTAL LABORATORY SECTOR VOLUME 1. Management and Technical Requirements for Laboratories Performing Environmental Analysis. EL-V1-2009 ENVIRONMENTAL LABORATORY SECTOR VOLUME 1 Management and Technical Requirements for Laboratories Performing Environmental Analysis TNI Standard P.O. Box 2439 Weatherford, TX 76086 817-598-1624

More information

A02 Assessment Rating Guide Revision 2.9 August 21, 2016

A02 Assessment Rating Guide Revision 2.9 August 21, 2016 Revision 2.9 August 21, 2016 Laboratory Name: Assessment Date: (Lead) Assessor: Signature: ! TABLE OF CONTENTS 1.0! INTRODUCTION... 1 2.0! ASSESSOR NOTES ON THE USE OF CALA A02 ASSESSMENT RATING GUIDE...

More information

A69 Checklist for Bulk Asbestos Revision 1.2 May 5, 2015

A69 Checklist for Bulk Asbestos Revision 1.2 May 5, 2015 A69 Checklist for Bulk Asbestos Revision 1.2 May 5, 2015 Laboratory Name: Appendix Name: Appendix Number: Assessor: Date: 01 DOCUMENT CONTROL 01 4.3 : is there a documented method? : Verify that the current

More information

Ainvolved in many aspects of project planning, sample collection,

Ainvolved in many aspects of project planning, sample collection, Chapter 3: SOME BASIC QA /QC CONCEPTS s coordinator of a volunteer monitoring program, you are probably Ainvolved in many aspects of project planning, sample collection, laboratory analysis, data review,

More information

DECISION TO ACCREDIT

DECISION TO ACCREDIT DECISION TO ACCREDIT Determine the requirements of the regulator, legislation and customer s needs prior to deciding on the standard to implement. Process is based on the following: Top management s decision

More information

A70 Checklist for Asbestos Fibre Counting Revision 1.11 March 21, 2018

A70 Checklist for Asbestos Fibre Counting Revision 1.11 March 21, 2018 A70 Checklist for Asbestos Fibre Counting Revision 1.11 March 21, 2018 Laboratory Name: Appendix Name: Appendix Number: Assessor: Date: A. EQUIPMENT I.D. ISO/IEC 17025:2005 (ISO/IEC 17025:2017) Requirement

More information

Procedure for Biomedical Equipment Calibration and Maintenance

Procedure for Biomedical Equipment Calibration and Maintenance Procedure for Biomedical Equipment Calibration and Maintenance 1.0 Purpose This procedure specifies the schedule and requirements for calibration, performance verification, and maintenance of Biomedical

More information

EA Guidance on Accreditation of Pesticide Residues Analysis in Food and Feed

EA Guidance on Accreditation of Pesticide Residues Analysis in Food and Feed Publication Reference EA-4/22 G: 2018 EA Guidance on Accreditation of Pesticide Residues Analysis in Food and Feed PURPOSE This paper provides guidance to develop harmonized accreditation of Pesticide

More information

Quality System Document

Quality System Document Title: Onsite Documents and Records Review List Page 1 of 6 In addition to those document sections indicated with an asterisk on the AIHA-LAP, LLC Application Review and Site Assessment Checklist, please

More information

EUROPEAN INDUSTRIAL PHARMACISTS GROUP. Guidance on CPD for QUALIFIED PERSONS

EUROPEAN INDUSTRIAL PHARMACISTS GROUP. Guidance on CPD for QUALIFIED PERSONS EUROPEAN INDUSTRIAL PHARMACISTS GROUP Guidance on CPD for QUALIFIED PERSONS EIPG Guidance on CPD for QP Continuing Professional Development for Qualified Persons, Technical Directors and other Responsible

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD FDIS ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories Exigences générales concernant la compétence des laboratoires d'étalonnages et

More information

Good practices in quality control in pharmaceutical industry - Overview of regulatory guidelines

Good practices in quality control in pharmaceutical industry - Overview of regulatory guidelines Review Article Good practices in quality control in pharmaceutical industry - Overview of regulatory guidelines Chagi Venkatesh*, S. B. Puranik ABSTRACT Good practices in quality control (QC) department

More information

American Association for Laboratory Accreditation

American Association for Laboratory Accreditation Page 1 of 35 The following pages present the Forensic Examination Accreditation specific requirements. The policies, procedures and activities of organizations performing forensic testing must meet these

More information

CALA Disputes

CALA Disputes Modify procedure so that management has formulated training goals, and that there are policies and procedures for identifying training needs and provision of training, with such training evaluated for

More information

Laboratory Quality Assurance Manager & Laboratory Assessor RULES & HANDBOOK

Laboratory Quality Assurance Manager & Laboratory Assessor RULES & HANDBOOK EOQ Personnel Registration Scheme Laboratory Quality Assurance Manager & RULES & HANDBOOK Prepared by: Dr. Eugenia Soboleva, Quality Austria In accordance with the working group on EOQ product development

More information

Good manufacturing practices

Good manufacturing practices ORIGINAL PAPER 1AR-10 ISBT Science Series (2009) 4, 6 10 Journal compilation 2009 International Society of Blood Transfusion Good manufacturing practices Blackwell Publishing Ltd A. Ahmed Quality Manager,

More information

Guidance Document. A Guide for the Validation and Approval of New Marine Biotoxin Test Methods. 10 April 2017

Guidance Document. A Guide for the Validation and Approval of New Marine Biotoxin Test Methods. 10 April 2017 Guidance Document A Guide for the Validation and Approval of New Marine Biotoxin Test Methods A guidance document issued by the Ministry for Primary Industries Title Guidance Document: Validation and Approval

More information

Registered Starting Material Auditing Guide

Registered Starting Material Auditing Guide Registered Starting Material Auditing Guide Annex 1 Aide Mémoire Company : Auditor(s) : Location, Country : Date of Audit: APIC Guide for Auditing Registered Starting Material Manufacturers Remark: Non-compliance

More information

QUALITY MANUAL ECO# REVISION DATE MGR QA A 2/25/2008 R.Clement J.Haislip B 6/17/2008 T.Finneran J.Haislip

QUALITY MANUAL ECO# REVISION DATE MGR QA A 2/25/2008 R.Clement J.Haislip B 6/17/2008 T.Finneran J.Haislip UHV SPUTTERING INC Page 1 of 18 ECO REVISION HISTORY ECO# REVISION DATE MGR QA 1001 A 2/25/2008 R.Clement J.Haislip 1017 B 6/17/2008 T.Finneran J.Haislip 1071 C 1/13/2011 R.Clement J.Haislip 1078 D 5/15/2013

More information

Documenta tion and Records

Documenta tion and Records Documenta tion and Records Page 1 of 30 Training Outcome of the Module: After completing this module, you will be able to: Recognize the importance of procedures Recognize the importance of record keeping

More information

General Accreditation Criteria Equipment assurance, in-house calibration and equipment verification

General Accreditation Criteria Equipment assurance, in-house calibration and equipment verification General Accreditation Criteria Equipment assurance, in-house calibration and equipment verification January 2018 Copyright National Association of Testing Authorities, Australia 2009 This publication is

More information

recovery and between 0% and 10% relative standard deviation.

recovery and between 0% and 10% relative standard deviation. THE NEED FOR ANALYTICAL QUALITY CONTROL IN ORDER TO MEET EFFLUENT PERMIT REGULATIONS IN THE METAL FINISHING INDUSTRY JEFFREY GLASS LABORATORY MANAGER ENVIROPACT, INC. MIAMI DIVISION 479 NW 157 STREET MIAMI,

More information

Document Review 1 2 3

Document Review 1 2 3 01 DOCUMENT CONTROL 01 4.3 The current authorized test method and (7.2.1.2) supporting work instructions are available to the analyst. 02 01 5.4 (7.2.1.5) TEST METHOD VERIFICATION/VALIDATION For standard

More information

Guidelines for the assessment of the appropriateness of small interlaboratory comparisons within the process of laboratory accreditation

Guidelines for the assessment of the appropriateness of small interlaboratory comparisons within the process of laboratory accreditation Publication Reference EA-4/21 INF: 2018 Guidelines for the assessment of the appropriateness of small interlaboratory comparisons within the process of laboratory accreditation PURPOSE This paper provides

More information

Accreditation of Reference Material Producers

Accreditation of Reference Material Producers Wilton Park House, Wilton Place, Dublin 2, Ireland Tel +353 1 607 3003 Fax +353 1 607 3109 E-mail inab@inab.ie Web www.inab.ie Accreditation of Reference Material Producers PS21 1) Purpose This statement

More information

Equipment In-house Calibration Requirements and use of Non-Accredited Calibration Service Providers

Equipment In-house Calibration Requirements and use of Non-Accredited Calibration Service Providers Issue 5.0: Provided additional clarification on record retention and non-conforming work with In- House calibration. Issue 6.0: Updated UL internal approvers only. No other changes. For Client Labs Purpose

More information

SAMM POLICY 10 (SP 10) GRADING OF NON- CONFORMITIES Issue 2, 28 February 2007 (Amd.1, 11 August 2014)

SAMM POLICY 10 (SP 10) GRADING OF NON- CONFORMITIES Issue 2, 28 February 2007 (Amd.1, 11 August 2014) SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA SAMM POLICY 10 (SP 10) GRADING OF NON- CONFORMITIES Issue 2, 28 February 2007 (Amd.1, 11 August 2014) JABATAN STANDARD

More information

A comparison of the complimentary and different issues in ISO/IEC and OECD GLP

A comparison of the complimentary and different issues in ISO/IEC and OECD GLP Accred Qual Assur (2003) 8:208 212 DOI 10.1007/s00769-003-0589-9 GENERAL PAPER Tina Engelhard Etty Feller Zahava Nizri A comparison of the complimentary and different issues in ISO/IEC 17025 and OECD GLP

More information

Raad voor Accreditatie (Dutch Accreditation Council RvA) Explanatory document on microbiology

Raad voor Accreditatie (Dutch Accreditation Council RvA) Explanatory document on microbiology Raad voor Accreditatie (Dutch Accreditation Council RvA) Explanatory document on microbiology Document code: A RvA-Explanatory note describes the policy and/or the procedures of the RvA concerning a specific

More information

Annex 13 WHO guidelines for preparing a laboratory information file

Annex 13 WHO guidelines for preparing a laboratory information file World Health Organization WHO Technical Report Series, No. 961, 2011 Annex 13 WHO guidelines for preparing a laboratory information file Background The WHO Expert Committee on Specifications for Pharmaceutical

More information

2010 PNCWA Conference Bend, OR

2010 PNCWA Conference Bend, OR 2010 PNCWA Conference Bend, OR Built in 1964,1971,1988, 1999, 2007, 2010 EPA Proposed Method Update Rule New Approved Methods and new versions of Old Approved Methods Revised Table of Holding Times and

More information

General Requirements for the Competence of Testing and Calibration Laboratories

General Requirements for the Competence of Testing and Calibration Laboratories ISO 17025:2005 POSITION PAPER General Requirements for the Competence of Testing and Calibration Laboratories EXECUTIVE SUMMARY This position paper provides a high-level overview of how LabVantage supports

More information

Angelia Dooley, MT, BS CRI Educational Surveyor. Terri Wolek, MBA, MT(ASCP) Bio-Rad Laboratories Senior Sales Product Manager

Angelia Dooley, MT, BS CRI Educational Surveyor. Terri Wolek, MBA, MT(ASCP) Bio-Rad Laboratories Senior Sales Product Manager Friday April 7, 2017 E46 IQCP in 2017: How s it Going? Angelia Dooley, MT, BS CRI Educational Surveyor Terri Wolek, MBA, MT(ASCP) Bio-Rad Laboratories Senior Sales Product Manager DESCRIPTION: Come to

More information

c) Have personnel been appointed to supervise the production operations across all shifts in order to ensure the product quality?

c) Have personnel been appointed to supervise the production operations across all shifts in order to ensure the product quality? Factory s Quality Assurance Ability 1 Responsibilities and Resources 1.1 Responsibilities a) Have the responsibilities and interrelation of various personnel involved in quality activities been defined?

More information

JFS-A/B/C Standards <Manufacturing> [Interpretations]

JFS-A/B/C Standards <Manufacturing> [Interpretations] JFS-A/B/C Standards [Interpretations] JFS-A Standard Ver. 1.1 JFS-B Standard Ver. 1.1 JFS-C Standard Ver. 2.2 Japan Food Safety Management Association September 15, 2017 Table of Contents

More information

Oklahoma Checklist (OK)

Oklahoma Checklist (OK) SubHeader : 01 General Information 001 Laboratory Name: OAC 252:301-1 002 Address: 003 Phone/Fax Number: 004 Date: 005 Primary POC: 006 Email/Website: 007 *Applicable to laboratories, which have performed

More information

PRM IMPLEMENTATION: QUALITY CONTROL

PRM IMPLEMENTATION: QUALITY CONTROL PRM IMPLEMENTATION: QUALITY CONTROL -----Quality Control in Laboratory Testing Agro-Environmental Quality Supervision & Testing Center, MOA (Tianjin) Zeying He hezeying222308@163.com Contents: 1. Overview

More information

Supplier Quality Survey. 1. Type of Business: g) Commodities supplied? Supplier Changes/comments: 2. Headcount breakdown by group: Purchasing

Supplier Quality Survey. 1. Type of Business: g) Commodities supplied? Supplier Changes/comments: 2. Headcount breakdown by group: Purchasing Supplier: Phone: Prime Contact/Title: Sales Contact/Title: Address: Fax: e-mail address e-mail address Quality Contact/Title: e-mail address 1. Type of Business: a) Number of years in business? b) Company

More information

GENERAL GUIDELINES FOR THE ACCREDITATION OF FOOD AND ENVIRONMENTAL MICROBIOLOGICAL LABORATORIES

GENERAL GUIDELINES FOR THE ACCREDITATION OF FOOD AND ENVIRONMENTAL MICROBIOLOGICAL LABORATORIES GENERAL GUIDELINES FOR THE ACCREDITATION OF FOOD AND ENVIRONMENTAL MICROBIOLOGICAL LABORATORIES ESYD G-MICROBIOL/01/02/20-10-2016 1/12 ESYD G-MICROBIOL Issue: 01 Revision: 02 Issue Date: 20-06-2007 Revision

More information

The TNI National Environmental Field Activities Program (TNI NEFAP)-Accreditation Procedure

The TNI National Environmental Field Activities Program (TNI NEFAP)-Accreditation Procedure PJLA offers third-party accreditation services to Conformity Assessment Bodies (i.e. Testing and/or Calibration Laboratories, Reference Material Producers, Field Sampling and Measurement Organizations

More information

APLAC GUIDELINES FOR FOOD TESTING LABORATORIES

APLAC GUIDELINES FOR FOOD TESTING LABORATORIES APLAC GUIDELINES FOR FOOD TESTING LABORATORIES Issue No. 2 Issue Date: 01/08 Page 1 of 13 PURPOSE This document provides guidance to APLAC members and their accredited laboratories on the operation of

More information

STATIONARY SOURCE AUDIT SAMPLE PROGRAM [VOLUME 1, MODULE 2] GENERAL REQUIREMENTS FOR AN ACCREDITOR OF STATIONARY SOURCE AUDIT SAMPLE PROVIDERS

STATIONARY SOURCE AUDIT SAMPLE PROGRAM [VOLUME 1, MODULE 2] GENERAL REQUIREMENTS FOR AN ACCREDITOR OF STATIONARY SOURCE AUDIT SAMPLE PROVIDERS [V1M2-2009]-Rev0.2 STATIONARY SOURCE AUDIT SAMPLE PROGRAM [VOLUME 1, MODULE 2] GENERAL REQUIREMENTS FOR AN ACCREDITOR OF STATIONARY SOURCE AUDIT SAMPLE PROVIDERS TNI Standard P.O. Box 2439 Weatherford,

More information

NEW YORK STATE DEPARTMENT OF HEALTH CLINICAL LABORATORY EVALUATION PROGRAM. Crosswalk of Proposed Revision to General Systems Standards

NEW YORK STATE DEPARTMENT OF HEALTH CLINICAL LABORATORY EVALUATION PROGRAM. Crosswalk of Proposed Revision to General Systems Standards Any General Systems Standards not addressed here remain in effect. (changes are underlined) CURRENT STANDARD CURRENT GUIDANCE PROPOSED STANDARD PROPOSED GUIDANCE Quality Management System Sustaining Standard

More information

Checklist for assessment of Metrological Traceability and Measurement Uncertainty of calibration laboratories NC NA

Checklist for assessment of Metrological Traceability and Measurement Uncertainty of calibration laboratories NC NA Calibration Laboratory Name: Address: Laboratory representative: Telephone: Place of assessments(specific cal.lab) Assessment Dates: Assessor(s): Technical expert(s) Assessment Type Requirements Calibration

More information

Speaker: Neville Taylor

Speaker: Neville Taylor Paper: The importance of Stability Testing in Proficiency Testing Author: Vijay Padayachee Vijay Consulting cc PO Box 2707, Johannesburg, 2000, South Africa E-mail: vpad@telkomsa.net Phone: +27 825795242

More information

Laboratory Validation. Chapter 16

Laboratory Validation. Chapter 16 Laboratory Validation Chapter 16 Importance The DNA profile is used to convict or free a suspect It must be perfect! No mistakes like we have in regular laboratories all the time Also DNA evidence must

More information

Pesticides: Method Validation and Quality Control

Pesticides: Method Validation and Quality Control The guidance in 10684/2009 is intended for laboratories control or in the monitoring of pesticide residues in food involved in official and feed in the European Union. The document describes the method

More information

Additional guidance on: TNsG on Data Requirements, Part A, Chapter 2, Point 4. Analytical Methods for Detection and Identification.

Additional guidance on: TNsG on Data Requirements, Part A, Chapter 2, Point 4. Analytical Methods for Detection and Identification. Additional guidance on: TNsG on Data Requirements, Part A, Chapter 2, Point 4 Analytical Methods for Detection and Identification and Part B, Chapter 2, Point 4 Methods of Identification and Analysis These

More information

MOLECULAR TESTING: VERIFYING/VALIDATING INSTRUMENTS, REAGENTS AND ASSAYS. Richard L. Hodinka, Ph.D.

MOLECULAR TESTING: VERIFYING/VALIDATING INSTRUMENTS, REAGENTS AND ASSAYS. Richard L. Hodinka, Ph.D. MOLECULAR TESTING: VERIFYING/VALIDATING INSTRUMENTS, REAGENTS AND ASSAYS Richard L. Hodinka, Ph.D. University of South Carolina School of Medicine Greenville Greenville Health System, Greenville, SC hodinka@greenvillemed.sc.edu

More information

ISTA Accreditation Standard for Seed Testing and Seed Sampling

ISTA Accreditation Standard for Seed Testing and Seed Sampling INTERNATIONAL SEED TESTING ASSOCIATION (ISTA) Secretariat, Zürichstrasse 50, 8303 Bassersdorf, CH-Switzerland Phone: +41-44-838 60 00, Fax: +41-44-838 60 01, Email: ista.office@ista.ch, http://www.seedtest.org

More information

Establishment of an Accredited Reference Measurement Laboratory

Establishment of an Accredited Reference Measurement Laboratory Establishment of an Accredited Reference Measurement Laboratory Francesco Dati, PhD IVD-Consulting Marburg / Germany E-mail: f.dati@t-online.de Quality of Analytical Systems Reference Measurement Systems

More information

Will Accrediting Authorities allow PT Providers to reissue a result report if the lab identifies a reporting problem? Sponsor: Bill Hall Resolution:

Will Accrediting Authorities allow PT Providers to reissue a result report if the lab identifies a reporting problem? Sponsor: Bill Hall Resolution: Will Accrediting Authorities allow PT Providers to reissue a result report if the lab identifies a reporting problem? Sponsor: Bill Hall Resolution: Accrediting Authorities will not accept re-issued reports

More information

A2LA. G123 - Guidance for Cannabis Laboratories Preparing for Accreditation

A2LA. G123 - Guidance for Cannabis Laboratories Preparing for Accreditation Page 1 of 6 Purpose: This document is intended to act as a guide to new cannabis testing laboratories to help determine the steps to take to prepare for accreditation, what is required as part of an application

More information

CRITERIA FOR VALIDATION OF METHODS USED BY CHEMICAL LABORATORIES AND RELATED INDUSTRIES

CRITERIA FOR VALIDATION OF METHODS USED BY CHEMICAL LABORATORIES AND RELATED INDUSTRIES Document No: SADCAS TR 17 Issue No: 1 CRITERIA FOR VALIDATION OF METHODS USED BY CHEMICAL LABORATORIES AND RELATED INDUSTRIES Prepared by: SADCAS Advisory Committee TLAP Approved by: SADCAS CEO Approval

More information

REVISION OF ISO/IEC GENERAL REQUIREMENTS FOR THE COMPETENCE OF TESTING AND CALIBRATION LABORATORIES

REVISION OF ISO/IEC GENERAL REQUIREMENTS FOR THE COMPETENCE OF TESTING AND CALIBRATION LABORATORIES REVISION OF ISO/IEC 17025 GENERAL REQUIREMENTS FOR THE COMPETENCE OF TESTING AND CALIBRATION LABORATORIES Presented August 10, 2017 to Environmental Measurement Symposium Warren Merkel, Co-convenor ISO/CASCO

More information

MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS

MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS 2D.1 SCOPE The AIHA- Laboratory Accreditation Programs (AIHA-LAP), LLC s Environmental Microbiological

More information

Urinalysis and Body Fluids CRg. Laboratory Regulation. Laboratory Regulation for Quality Assessment. Unit 1 B. Quality Assessment

Urinalysis and Body Fluids CRg. Laboratory Regulation. Laboratory Regulation for Quality Assessment. Unit 1 B. Quality Assessment Urinalysis and Body Fluids CRg Unit 1 B Laboratory Regulation Federal Regulations / Regulatory Organizations Laboratory structure / operation Quality test performed by qualified personnel to obtain quality

More information

Measurement Uncertainty Guide. ISO Accreditation Program

Measurement Uncertainty Guide. ISO Accreditation Program Measurement Uncertainty Guide ISO 15189 Accreditation Program Background Why This is Necessary The ISO 15189:2012 standard contains enhanced expectations regarding measurement uncertainty (MU) in clause

More information

ISO 22000:2005 Standard INTERNATIONAL STANDARDS REGISTRATIONS

ISO 22000:2005 Standard INTERNATIONAL STANDARDS REGISTRATIONS ISO 22000:2005 Standard Food Safety Management System INTERNATIONAL STANDARDS REGISTRATIONS 3.1 FOOD SAFETY concept that food will not cause harm to the consumer when it is prepared and/or eaten according

More information

COMPLIANCE BY DESIGN FOR PHARMACEUTICAL QUALITY CONTROL LABORATORIES INSIGHT FROM FDA WARNING LETTERS

COMPLIANCE BY DESIGN FOR PHARMACEUTICAL QUALITY CONTROL LABORATORIES INSIGHT FROM FDA WARNING LETTERS COMPLIANCE BY DESIGN FOR PHARMACEUTICAL QUALITY CONTROL LABORATORIES INSIGHT FROM FDA WARNING LETTERS Primer CONTENTS INTRODUCTION...3 QUALITY AND COMPLIANCE IN QUALITY CONTROL LABORATORIES...5 Compliance

More information

QA/QC to underpin the measurement cycle

QA/QC to underpin the measurement cycle QA/QC to underpin the measurement cycle Lisbon, 21 May 2014 - ACCREDIA 1 / 15 21 May 2014 ISO/IEC 17025:2005 5.9 Assuring the quality of test and calibration results 5.9.1 The laboratory shall have quality

More information

The EA Laboratory Committee point of view of IQC activities. Ioannis Sitaras, Hellenic Accreditation System S.A-ESYD, Greece

The EA Laboratory Committee point of view of IQC activities. Ioannis Sitaras, Hellenic Accreditation System S.A-ESYD, Greece EURACHEM WORKSHOP Key Challenges in Internal Quality Control, Berlin 10-11 October 2012 The EA Laboratory Committee point of view of IQC activities Ioannis Sitaras, Hellenic Accreditation System S.A-ESYD,

More information

METHOD VALIDATION TECHNIQUES PREPARED FOR ENAO ASSESSOR CALIBRATION COURSE OCTOBER/NOVEMBER 2012

METHOD VALIDATION TECHNIQUES PREPARED FOR ENAO ASSESSOR CALIBRATION COURSE OCTOBER/NOVEMBER 2012 METHOD VALIDATION PREPARED FOR ENAO ASSESSOR CALIBRATION COURSE TECHNIQUES OCTOBER/NOVEMBER 2012 Prepared by for ENAO Assessor Calibration B SCOPE Introduction House Rules Central Tendency Statistics Population

More information

Revision. Quality Manual. Multilayer Prototypes. Compliant to ISO / AS9100 Rev C

Revision. Quality Manual. Multilayer Prototypes. Compliant to ISO / AS9100 Rev C 1 of 29 Quality Manual Multilayer Prototypes Compliant to ISO 9001-2008 / AS9100 Rev C This Quality Manual sets forth the quality system policies and Defines compliance with the ISO 9001-2008 SAE AS 9100

More information

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *)

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *) VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *) Guideline Title Validation of Analytical Procedures: Methodology Legislative basis Directive 75/318/EEC as amended Date of first adoption December 1996

More information

The Hashemite Kingdom of Jordan Jordan Institution for Standards & Metrology. Jordanian Quality Mark

The Hashemite Kingdom of Jordan Jordan Institution for Standards & Metrology. Jordanian Quality Mark The Hashemite Kingdom of Jordan Jordan Institution for Standards & Metrology Jordanian Quality Mark Amman in February, 1997 1 Abstract Article (18) of the Law of Standards & Metrology; law no. (15) for

More information

Summary of TL 9000 R4.0 Requirements Beyond ISO 9001:2000

Summary of TL 9000 R4.0 Requirements Beyond ISO 9001:2000 This summary identifies the additional TL 9000 Release 4.0 requirements beyond those stated in ISO 9001:2000. See the TL 9000 R4.0 Handbook for the actual TL 9000 R4.0 requirements. ISO 9001:2000 section

More information

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE 5/06/08

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE 5/06/08 1 of 69 Preface The New York State Department of Health, Wadsworth Center, Environmental Laboratory Approval Program (ELAP) has adopted as its Standard the current version of the National Environmental

More information

Laboratory Management & Quality Assurance

Laboratory Management & Quality Assurance Laboratory Management & Quality Assurance Samer Al-Kharouf Royal Scientific Society, Jordan What is QA? A set of documented procedures and practices that, when effectively applied, insure a product with

More information

R205: SPECIFIC REQUIREMENTS: CALIBRATION LABORATORY ACCREDITATION PROGRAM. December 2011

R205: SPECIFIC REQUIREMENTS: CALIBRATION LABORATORY ACCREDITATION PROGRAM. December 2011 Page 1 of 12 R205: SPECIFIC REQUIREMENTS: CALIBRATION LABORATORY ACCREDITATION PROGRAM December 2011 2011 by A2LA All rights reserved. No part of this document may be reproduced in any form or by any means

More information

Quality System Guidance

Quality System Guidance Page 1 of 16 TABLE OF CONTENTS 1.0 SCOPE... 2 2.0 REFERENCES... 2 3.0 TERMS AND DEFINITIONS... 2 4.0 BACKGROUND... 5 5.0 GUIDANCE ON IMPLEMENTATION... 5 5.1 Choosing Type A or Type B... 6 5.2 General considerations...

More information

Correspondence between ICMED criteria and ISO 13485: 2012

Correspondence between ICMED criteria and ISO 13485: 2012 Annexure A (Informative) Correspondence between ICMED 13485 criteria and ISO 13485: 2012 Green Font is additional ICMED 13485 criteria requirement. Additional ICMED 13485 criteria Requirements are also

More information