Surface Plasmon Resonance Analyzer
|
|
- Cassandra Fleming
- 6 years ago
- Views:
Transcription
1 Surface Plasmon Resonance Analyzer
2
3
4
5
6
7 5 6 SPR System Based on Microfluidics Wide Dynamic Range Kinetic Analysis by Detection of Association /Dissociation of Bio-Molecules Measuring of Mass Change below ~10nM. The SPR signal originates in changes in the refractive index at the surface layer, caused by concentration changed on the sensor chip surface with adsorbed bio-molecules. The SPR is detected by measurement of the intensity of reflected light. From the SPR angle, a sharp decrease or dip in intensity can be measured. Any change in thickness or index of refraction of the material adsorbed onto gold surface results in a shift of the SPR angle. The SPR angle shift is used as a response unit to quantify binding molecules to the sensor surface. Principles of Photo diode Detector Polarized Light Analyte Solution of Protein Θ Glass (10mm) Coupling Prism Flow Cell Refractive Index Inject Ligand Inject Analyte Ligand Self assembled monolayer 50mm Gold Surface Cr (2nm) Au (50nm) SAM (~3nm) Substance Prism Time Surface refractive index is monitored over time as binding events occur.
8 SOFTWARE Measurement Mode Pre-scanning Mode (θ-r plot) : Incident angle vs Reflectance Pre-scanning mode is the method for measuring reflectance intensity as incident angle of the p-polarized light source and finding minimum reflectance angle. This mode is the angle resolution of 0.01 ~ 0.5 degree and measurement range within 30 ~ 80 degree. Fixed Angle Mode ( T-R plot) : Time vs Reflectance Fixed angle mode is the method for finding the maximum slope of the SPR curve and measuring the reflectivity with real time at this fixed angle. This process is performed in order to rapid monitoring at the minimum 0.2 second interval. As a measuring of change of reflectance with time function, this mode is displayed by Time vs Reflectance intensity change. Repeated Angle Mode ( T- Rθ plot): Time vs Resonance angle Repeated angle mode is the method for measuring the change of minimum resonance angle in the constant narrow angle range by repeatedly angle scanning and fitting. As a measuring of resonance angle shift with time function, this mode is displayed by Time vs Resonance angle change. Analysis Mode The interpretation of the measurement data and of the experimental result using the Simulation Mode, estimation of the experimental result, comparison with the result of theoretical and experimental.
9 7 8 SPECIFICATION DIMENSIONS Measurement Method Angle Scan Sensor & Sample Flow Sample Flow Channel 1 Sensing Point 1 Flow Tube 0.5mm(dia.) Light Source Semiconductor Laser(635nm, 2.5mW) Flow cell Material PEEK + Kalrez O-ring Sensor System Detector Incident Angle Range 1 Photodiode degree Flow System Flow Tube Material Flow rate PEEK 5-100ul/min Incident Angle Change Mechanism Pulse Motor Sample Volume Sample Cell : 8.06 ul Injection Volume : < 100ul (changeable) Au Coated Substrate 18(W) 18(D) 10(H) mm Pump Method 1 Syringe Pump for Buffer and Sample Outer Dimensions Weight Power Supply Software(Window 98, 2000, XP) 600(D) 450(W) 270(H) mm 45 kg AC 220V, 60Hz SPR LAB Ver.2.X Temp. Control System Sample Injection Method Control Range Control Method Temp. Accuracy 2-Position Injection Valve(10port) 1st Loop for Sample, 2nd Loop for Air From 4 to 40 (5 /hr) Peltier Element ± UNIT : mm
10
11 9 10 SPR Imaging System Based on Array type High Throughput Screening of Target Molecules. Rapid Monitoring of Biochip Ease to Use Powerful image Processing S/W With the advance of proteomics and the requirement of analysis of a variety of expressed proteins, rapid and high-throughput detection of the proteins is the hot issue. SPRi detects the specific binding of unlabeled bio-molecules to arrayed capture molecules attached to a modified gold thin film by measuring changes in the local index of refraction upon adsorption. It has been proven to be a valuable tool for investigating molecular interactions without the use of any fluorescent or radiochemical labels. SPR imaging using fast optical array detectors permits simultaneous measurements across an array of immobilized molecules. SPR imaging provides excellent spatial resolution at the same sensitivity as classical SPR. These features make SPR imaging a promising detection technology for biochips. Also, SPR imaging has applied to bioanalytical chemistry such as label-free investigation of enzyme substrate interactions, DNA hybridization, antibody antigen binding and protein DNA or protein protein. Principles of Parallel Beam Analyte Metal Layer Prism ΔR ra rr α Light Source CCD array Schematic of SPR imaging. A parallel beam is incident on a prism near the SPR resonance angle. The reflected light is detected by a CCD Array. Contrast in SPR image arises from variation in the reflected light intensity ΔR.
12 SOFTWARE Spot detection Viewer This viewer is display detection of target spot and information of spot, which is apply to setting range of detection spot and background. The detection method is automation and manual type. Line Profile Viewer It is the viewer that display line intensity profiling of X axis or Y- axis image using 2-Dimension image data 3 Dimension Viewer It is the viewer that display 3-Dimension image based on intensity of 2-Dimension image data, which is measuring or loading 3D Image Protein Concentration
13 11 12 SPECIFICATION DIMENSIONS Sensor System Measurement Method Sensing Point Light Source Detector Prism Material Incident Angle Change Mechanism Au Coated Substrate Intensity Interrogation Array Light Emitting Diode (760nm) 2D Charge Coupled Device (CCD) BK7, SF10, Fused Silica, BaCD4 or User Modify available Manual type 18(W) x 18(D) x 0.5(H) mm Outer Dimensions Weight Power Supply Software(Window 98, 2000, XP) 430(W) x 380(D) x 430(H) 30kg AC 220V, 60(Hz) MS window XP UNIT : mm
14
15 GOLD CHIP The sensor chip is the signal transducer in real time SPR. The chip is a glass slide with a thin layer of gold deposited on one side. Gold is chosen for its combination of chemical inertness and good SPR response. The gold film on the sensor chip is covered with a covalently bound matrix to which bio-molecules may be immobilized using well defined chemistry. Types of Gold Chip Model Specipication G1 G2 G1 10 mm 12 mm 0.3 mm G2 18 mm 18 mm 0.3 mm G3 G4 G3 25Φ 1.0 mm G4 Block Prism 90 G5 G6 25mm 25mm 1.0mm, BK7 Silicone wafer(4") G5 G9 G7 SF10 Glass G8 Quartz cell G9 G10 Slide Glass Reaction Chamber G6 G11 Prism reference G12 Order Made
16 13 14 ACCESSORY Cleaning & Reaction Holder Constant Temperature Incubator Types Prism coupled chip holder (PCH5, PCH1) Slide chip holder (SCH) PCH5 PCH1 Power Supply Control Range Resolution Display Interface AC220V, 60Hz From 4 to /min Character LCD Key pad type SCH1 The holders can be used SPR sensor chip cleaning and reaction such as SAM formation UNIT : mm
17 Korea Headquarters 554 Yongsan-dong, Yuseong-gu, Daejeon, Korea Tel.: Fax: Taiwan Branch 3F., No. 42, Singjhong Rd., Neihu District, Taipei City 114, Taiwan ROC Tel.: Fax: Beijing Office zhuanglou, fuyuandongli 2qu, Beijing jingji jishu kaifaqu, Beijing, China Tel.: (ext.:878) Fax: Kunshan Office 41 haobieshu, Zitenghuayuan, Kunshan, Jiangsu , China Tel.: Fax: K-MAC R&D Center Address : Munji-dong, Yuseong-gu, Daejeon, , Korea Tel : , Fax : spr@kmac.to
18
Biomarker Discovery using Surface Plasmon Resonance Imaging
F e a t u r e A r t i c l e Feature Article Biomarker Discovery using Surface Plasmon Resonance Imaging Elodie LY-MORIN, Sophie BELLON, Géraldine MÉLIZZI, Chiraz FRYDMAN Surface Plasmon Resonance (SPR)
More informationExplore the future. Automotive Test Systems Process & Environmental Medical Semiconductor Scientific
Explore the future Automotive Test Systems Process & Environmental Medical Semiconductor Scientific Label-free Bio-Affinity Analysis Surface Plasmon Resonance (SPR) is an established tool in the life science
More informationSURFACE PLASMON RESONANCE-BASED SYSTEMS
SURFACE PLASMON RESONANCE-BASED SYSTEMS ADVANCED METHODS IN BIOENGINEERING LABORATORY 3/1/2011 1 Schedule Week 1: Introduction Reagents preparation Ligand immobilization of Protocol 1 Week 2: Kinetics
More informationLabel-free interaction analysis in realtime using surface plasmon resonance
GE Healthcare Technology Note 23 Biacore systems Label-free interaction analysis in realtime using surface plasmon resonance Providing quantitative data on: report point Specificity sensorgram To what
More informationNanophotonics: principle and application. Khai Q. Le Lecture 11 Optical biosensors
Nanophotonics: principle and application Khai Q. Le Lecture 11 Optical biosensors Outline Biosensors: Introduction Optical Biosensors Label-Free Biosensor: Ringresonator Theory Measurements: Bulk sensing
More informationSurface Plasmon Resonance Systems
Innovative precision instruments for over a century Surface Plasmon Resonance Systems Label-free Molecular Interaction Analysis ReichertSPR Answers: Is there an interaction? How fast? How strong? How long?
More informationCharacterization of Aptamer Binding using SensíQ SPR Platforms
Characterization of Aptamer Binding using SensíQ SPR Platforms APPLICATION NOTE INTRODUCTION Aptamers have the potential to provide a better solution in diagnostics and other research areas than traditional
More informationBiacore. Sensor Surface Handbook
Biacore Sensor Surface Handbook Contents 1 Introduction 1.1 Principles of Biacore systems... 7 1.2 Biacore terminology... 7 1.3 Components of Biacore systems... 9 1.3.1 The SPR detection system... 9 1.3.2
More informationIn-Situ Monitoring of Pattern Filling in Nano-Imprint Lithography Using Surface Plasmon Resonance
Copyright 2011 American Scientific Publishers All rights reserved Printed in the United States of America Journal of Nanoscience and Nanotechnology Vol. 11, 1 6, 2011 In-Situ Monitoring of Pattern Filling
More informationSolvent Correction versus In-line Reference Measurement
Technical Note Solvent Correction versus In-line Reference Measurement Optical systems such as SPR and BLI often have difficulty with nonspecific noise when measuring low molecular weight analyte in organic
More informationInterferometric optical biosensor. Xingwei Wang
Interferometric optical biosensor Xingwei Wang 1 Light Transverse electromagnetic wave Reflection Refraction Diffraction Interference 2 Fabry-Perot interferometer 3 Interferometer Two waves that coincide
More informationProtein Interaction Analysis
/proteininteraction/ ProteOn XPR36 Protein Interaction Array System 310 Instrument 310 Software 312 Regulatory Tools 314 Sensor Chips 315 Kits, Reagents, and Consumables 317 Protein Interaction Analysis
More informationTime-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements
Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements Technical Overview Authors Dr. Fabian Zieschang, Katherine MacNamara,
More informationNanoSystemsEngineering: NanoNose Final Status, March 2011
1 NanoSystemsEngineering: NanoNose Final Status, March 2011 The Nanonose project is based on four research projects (VCSELs, 3D nanolithography, coatings and system integration). Below, the major achievements
More informationIntroduction of Biosensors
Introduction of Biosensors Lecture April 17 Jeff T.H.Wang website: http://pegasus.me.jhu.edu/~thwang/ New course : BioMEMS and BioSensing (Spring 04 ) What s is a biosensor? Target 4.22 Signal Signal Analtye
More informationThe World Leader in SPR Technology. Jimmy Page, PhD, Biacore, Inc.
The World Leader in SPR Technology Jimmy Page, PhD, Biacore, Inc. Objectives of Biacore Experiments Yes/No Data» Is there binding?» Ligand Fishing Concentration Analysis: How MUCH? Active Concentration
More informationUsing ULS24 CMOS Bio-imager as a Readout Sensor for Chemiluminescence Immunoassay and DNA Hybridization Assay
Using ULS24 CMOS Bio-imager as a Readout Sensor for Chemiluminescence Immunoassay and DNA Hybridization Assay Updated: Nov 11, 2016 Introduction Immunoassay is a widely used method for detecting the presence
More informationReducing Non-Specific Binding in Surface Plasmon Resonance Experiments
1 Reducing Non-Specific Binding in Surface Plasmon Resonance Experiments SUMMARY Reducing non-specific binding (NSB) is essential to generating accurate data with SPR The effect of bovine serum albumin,
More informationprotein interaction analysis tech note 5367
protein interaction analysis tech note 5367 Rapid Optimization of Immobilization and Binding Conditions for Kinetic Analysis of Protein-Protein Interactions Using the ProteOn XPR36 Protein Interaction
More informationMicroarray Industry Products
Via Nicaragua, 12-14 00040 Pomezia (Roma) Phone: +39 06 91601628 Fax: +39 06 91612477 info@lifelinelab.com www.lifelinelab.com Microarray Industry Products Page 10 NBT / BCPIP Chromogenic phosphatase
More informationBIA Experimental Designs
s What are the Basics? Immobilization Binding Interactions Regenerations Controls 1 BIA Terminologies Ligand : Bound component Analyte: Flow-through component BIA Terminologies Resonance Units: Units used
More informationX-ray Photoelectron Spectroscopy
X-ray Photoelectron Spectroscopy X-ray photoelectron spectroscopy (XPS) is a non-destructive technique used to analyze the elemental compositions, chemical and electronic states of materials. XPS has a
More informationThermo Scientific GENESYS 10S Bio spectrophotometer
PRODUCT SPECIFICATIONS GENESYS 10S Bio UV-Visible Spectrophotometer Thermo Scientific GENESYS 10S Bio spectrophotometer Accurate and convenient life science UV-Visible measurements Designed for performance
More informationQuantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging
Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging Introduction In this application note, we will discuss the application of quantum dots in fluorescence imaging, both
More informationProperties of nanofabricated biosensors based on DNA aptamers
Properties of nanofabricated biosensors based on DNA aptamers Tibor Hianik Faculty of Mathematics, Physics and Computer Sci., Comenius University, Bratislava, Slovakia Content of presentation Introduction
More informationOptical Observation - Hyperspectral Characterization of Nano-scale Materials In-situ
Optical Observation - Hyperspectral Characterization of Nano-scale Materials In-situ Research at the nanoscale is more effective, when research teams can quickly and easily observe and characterize a wide
More informationCalculation of Stress And Deflection In Double Layer Microcantilever For Biosensor Application
Calculation of Stress And Deflection In Double Layer Microcantilever For Biosensor Application 1,2 Lia Aprilia, 1 Ratno Nuryadi, 2 Djoko Hartanto 1 Center for Material Technology, Agency for the Assessment
More informationBiacore The high performance research system. Work with high sensitivity
Biacore 3000 The high performance research system Work with high sensitivity direct detection of small molecules at < 1 nm concentration increased resolution for kinetic analysis measurement of weak affinities
More informationLPR Sensor Made by Using Ordered Porous Alumina
UDC 669.716.9+669.218+534.428+615.076 LPR Sensor Made by Using Ordered Porous Alumina Yuichi TOMARU*, Takeharu TANI*, Yoshinori HOTTA**, Yusuke HATANAKA**, and Masayuki NAYA* Abstract We fabricated a LPR
More informationFY06 ACCOMPLISHMENTS. Nanoelectronics Manufacture, Inspection, and Repair using Thermal Dip Pen Nanolithography
FY06 ACCOMPLISHMENTS Nanoelectronics Manufacture, Inspection, and Repair using Thermal Dip Pen Nanolithography William P. King Georiga Institute of Technology FY06 was the second year of this grant, and
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent 11896A and 8169A Polarization Controllers Product Overview Automatic polarization state adjustments for polarizationdependent
More informationLabel-Enhanced SPR Improves the Detectability of Label-Free Surface Plasmon Resonance Analysis 100x
episentec Label-Enhanced SPR Improves the Detectability of Label-Free Surface Plasmon Resonance Analysis 1x Anders Hanning, Episentec Drug Discovery 15, Telford, 2-3 September 215 Episentec - Better Biosensors
More informationQuality in Electronic Production has a Name: Viscom. System Overview
Quality in Electronic Production has a Name: Viscom System Overview Successful along the whole line with Viscom Circuit board manufacturing Paste print Finish S3070 AFI-Scan S3054QS Paste print Thick film
More informationHPCE-5 2. Realising the potential of Capillary Electrophoresis. Why is the HPCE-512 so much better?
HPCE-5 2 Realising the potential of Capillary Electrophoresis Why is the HPCE-512 so much better? A Major Advance in Capillary Electrophoresis The HPCE-512 system based on multi-point detection overcomes
More informationBIOSENOSRS BIO 580. Nanobiosensors WEEK-13 Fall Semester. Faculty: Dr. Javed H. Niazi KM Faculty of Engineering & Natural Sciences Sabanci University
BIOSENOSRS BIO 580 Nanobiosensors WEEK-13 Fall Semester Faculty: Dr. Javed H. Niazi KM Faculty of Engineering & Natural Sciences Sabanci University Topics that will be covered in the course History of
More informationBiacore X100. GE Healthcare Life Sciences. Biacore X100 Plus Package. Biacore X100 delivers:
GE Healthcare Life Sciences Data file 28-9592-29 AB Biacore label-free interaction analysis Biacore X100 Biacore X100 (Fig 1) is an automated and versatile system for comprehensive, label-free analysis
More informationA handheld system for DNA test based on Lab on chip technologies. Marco Bianchessi
A handheld system for DNA test based on Lab on chip technologies Marco Bianchessi History 2 Mid 90s: Lab on chip introduction From niche to high-volumes products What is needed: 3 Miniaturization 75 000
More informationN-Lab. Extend your research. New generation label-free surface analysis system
N-Lab Extend your research New generation label-free surface analysis system SEEC technique Application areas A NEW WAY TO ANALYSE YOUR SAMPLE! SEEC* technique is a label free quantitative imaging technique
More informationPlease note that in order to obtain useful results, the input values should be in the correct units (as indicated per input cell).
1. Calculations This document contains a number of formulas used with surface plasmon resonance and biomolecular interaction analysis. For the convenience of the reader, an Excel spreadsheet (.xlsm) is
More informationMaterial-independent Fabrication of Superhydrophobic Surfaces by Musselinspired
Electronic Supplementary Material (ESI) for RSC Advances. This journal is The Royal Society of Chemistry 2014 Material-independent Fabrication of Superhydrophobic Surfaces by Musselinspired Polydopamine
More informationElectrophoresis and the Agilent Bioanalyzer. Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008
Electrophoresis and the Agilent Bioanalyzer Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008 Introduction Electrophoresis is one of the most commonlyused methods of separating
More informationProtein Microarrays?
Protein Microarrays? Protein Chemistry/Proteomics Unit and the Neuroscience Program,Biomedicum Helsinki E-Mail: marc.baumann@helsinki.fi (http://research.med.helsinki.fi/corefacilities/proteinchem) What
More informationWhite Paper: Pixelligent Internal Light Extraction Layer for OLED Lighting
White Paper: Pixelligent Internal Light Zhiyun (Gene) Chen, Ph.D., Vice President of Engineering Jian Wang, Ph.D., Manager, Application Engineering Pixelligent Technologies LLC, 6411 Beckley Street, Baltimore,
More informationGE Biacore T Check that the waste bottle is empty.
GE Biacore T200 General Care and Maintenance The instrument should be left ON at all times, and in Standby Mode. Report problems immediately in the booking system: https://ppms.us/hms-cmi. Refer to the
More informationAdvantages of Photodiode Array
Advantages of Photodiode Array Hun Choi SCINCO. Co., Ltd. 74-27 Nonhyun-dong, Kangnam-ku, Seoul, Korea, 135-010 Preface All products are continuously being improved for better performance. Spectrometers
More informationOptical Coatings. Photonics 4 Luxury Coatings , Genève. Dr. Andreas Bächli Head of Optical Coatings at RhySearch, Buchs (SG)
Optical Coatings Photonics 4 Luxury Coatings 21.06.2017, Genève Dr. Andreas Bächli Head of Optical Coatings at RhySearch, Buchs (SG) RhySearch The Research- and Innovation Center in the Rhine Valley RhySearch
More informationImprovement of Laser Fuse Processing of Fine Pitch Link Structures for Advanced Memory Designs
Improvement of Laser Fuse Processing of Fine Pitch Link Structures for Advanced Memory Designs Joohan Lee, Joseph J. Griffiths, and James Cordingley GSI Group Inc. 60 Fordham Rd. Wilmington, MA 01887 jlee@gsig.com
More informationChallenges and Future Directions of Laser Fuse Processing in Memory Repair
Challenges and Future Directions of Laser Fuse Processing in Memory Repair Bo Gu, * T. Coughlin, B. Maxwell, J. Griffiths, J. Lee, J. Cordingley, S. Johnson, E. Karagiannis, J. Ehrmann GSI Lumonics, Inc.
More informationBiochemical Analysis The Lambda Series UV/Vis Spectroscopy
Inorganic Analysis Chromatography Molecular Spectroscopy Thermal Analysis Informatics UV/Vis Spectroscopy Biochemical Analysis The Lambda Series P R O D U C T N O T E www.perkinelmer.com Bioresearch laboratories
More informationEvaluation of Mechanical Properties of Hard Coatings
Evaluation of Mechanical Properties of Hard Coatings Comprehensive mechanical testing of two coated metal samples was performed on the UNMT- 1. The tests clearly distinguished brittle and ductile samples,
More informationBiophysical characterization of proteinprotein
Biophysical characterization of proteinprotein interactions Rob Meijers EMBL Hamburg EMBO Global Exchange Lecture Course Hyderabad 2012 Bottom up look at protein-protein interactions Role of hydrogen bonds
More informationPlasmonic Nanostructures II
Plasmonic Nanostructures II Dr. Krüger / Prof. M. Zacharias, IMTEK, Propagation of SPPs Propagation distance decreases with decreasing strip width! 2 Dr. Krüger / Prof. M. Zacharias, IMTEK, Bound and leaky
More informationNanoscale Imaging, Material Removal and Deposition for Fabrication of Cutting-edge Semiconductor Devices
Hitachi Review Vol. 65 (2016), No. 7 233 Featured Articles Nanoscale Imaging, Material Removal and Deposition for Fabrication of Cutting-edge Semiconductor Devices Ion-beam-based Photomask Defect Repair
More informationMeasurement of thickness of native silicon dioxide with a scanning electron microscope
Measurement of thickness of native silicon dioxide with a scanning electron microscope V. P. Gavrilenko* a, Yu. A. Novikov b, A. V. Rakov b, P. A. Todua a a Center for Surface and Vacuum Research, 40 Novatorov
More informationMicrowave Plasma Processing
Microwave Plasma Processing MUEGGE GMBH Hochstraße 4-6 64385 Reichelsheim Fon +49 (0) 6164-93 07 11 Fax +49 (0) 6164-93 07 93 info@muegge.de www.muegge.de Microwave Plasma Processing Microwave Plasma Technology:
More informationMeasurement data at orders of magnitude lower cost than other techniques BENEFITS Simple UVC source ideal for compact sensors
Optan The Optan Ball Lens, with integrated focusing optics, is the first choice for discerning professionals developing sensors and instruments in demanding measurement applications. Designed for and proven
More informationHigh Resolution X-ray Diffraction
High Resolution X-ray Diffraction Nina Heinig with data from Dr. Zhihao Donovan Chen, Panalytical and slides from Colorado State University Outline Watlab s new tool: Panalytical MRD system Techniques:
More informationCREOL, The College of Optics & Photonics, University of Central Florida
Metal Substrate Induced Control of Ag Nanoparticle Plasmon Resonances for Tunable SERS Substrates Pieter G. Kik 1, Amitabh Ghoshal 1, Manuel Marquez 2 and Min Hu 1 1 CREOL, The College of Optics and Photonics,
More informationApplication Note AN001
Testing hybridoma supernatants with the Spots On Dots Antibody Screening Kit Application Note AN1 Table of Contents Overview... 2 Figure 1. Screening of hybridomas raised against peptide antigens... 3
More informationOLED/OPD transducer for point-of-use diagnostics
OLED/OPD transducer for point-of-use diagnostics Overview 1. CDT overview + Biosensor platform overview CDT overview Absorbance based lateral flow device (LFD) basics and advantages Abingdon Health collaboration
More informationNanoimprinting in Polymers and Applications in Cell Studies. Albert F. YEE Chemical Engineering & Materials Science UC Irvine
Nanoimprinting in Polymers and Applications in Cell Studies Albert F. YEE Chemical Engineering & Materials Science UC Irvine Presentation outline Motivation Reversal imprinting Soft inkpad imprinting on
More informationCyBi -HummingWell. Compound Transfer Directly from Stock!
CyBi -HummingWell Compound Transfer Directly from Stock! 2 CyBi -HummingWell Compound Transfer Directly from Stock! The CyBi -HummingWell Why parallel compound transfer apart from automation? Since there
More informationTransmission Kikuchi Diffraction in the Scanning Electron Microscope
Transmission Kikuchi Diffraction in the Scanning Electron Microscope Robert Keller, Roy Geiss, Katherine Rice National Institute of Standards and Technology Nanoscale Reliability Group Boulder, Colorado
More informationDrug Discovery Research Clinical Screening. Comparison of ELISA and AlphaScreen Assay Technologies for Measurement of Protein Expression Levels
Drug Discovery Research Clinical Screening FLAG Expression Measurement Application Note Comparison of ELISA and AlphaScreen Assay Technologies for Measurement of Protein Expression Levels ALPHASCREEN APPLICATION
More informationSurface Acoustic Wave fabrication using nanoimprint. Zachary J. Davis, Senior Consultant,
Surface Acoustic Wave fabrication using nanoimprint Zachary J. Davis, Senior Consultant, zjd@teknologisk.dk Center for Microtechnology & Surface Analysis Micro and Nano Technology Sensor Technology Top
More informationOMICS Group signed an agreement with more than International Societies to make healthcare informati on Open Access. OMICS Group Conferences
About Omics Group OMICS Group International through its Open Ac cess Initiative is committed to make genuine an d reliable contributions to the scientific commu nity. OMICS Group hosts over 400 leading-edg
More informationBONDING OF MULTIPLE WAFERS FOR HIGH THROUGHPUT LED PRODUCTION. S. Sood and A. Wong
10.1149/1.2982882 The Electrochemical Society BONDING OF MULTIPLE WAFERS FOR HIGH THROUGHPUT LED PRODUCTION S. Sood and A. Wong Wafer Bonder Division, SUSS MicroTec Inc., 228 SUSS Drive, Waterbury Center,
More informationSolar Flat Plate Thermal Collector
Solar Flat Plate Thermal Collector 1 OBJECTIVE: Performance Study of Solar Flat Plate Thermal Collector Operation with Variation in Mass Flow Rate and Level of Radiation INTRODUCTION: Solar water heater
More informationDolphin-Chemi Plus. Aim: To visualise and evaluate the performance of chemiluminescent immunoblots using Wealtec s Dolphin-Chemi plus image system
Application Note 03 Dolphin-Chemi plus 8/22/2007 Dolphin-Chemi Plus Aim: To visualise and evaluate the performance of chemiluminescent immunoblots using Wealtec s Dolphin-Chemi plus image system INTRODUCTION
More informationTrench Structure Improvement of Thermo-Optic Waveguides
International Journal of Applied Science and Engineering 2007. 5, 1: 1-5 Trench Structure Improvement of Thermo-Optic Waveguides Fang-Lin Chao * Chaoyang University of Technology, Wufong, Taichung County
More informationMICROFABRICATION OF OPTICALLY ACTIVE InO X MICROSTRUCTURES BY ULTRASHORT LASER PULSES
Journal of Optoelectronics and Advanced Materials Vol. 4, No. 3, September 2002, p. 809-812 MICROFABRICATION OF OPTICALLY ACTIVE InO X MICROSTRUCTURES BY ULTRASHORT LASER PULSES Foundation for Research
More informationNew Evaluation Methods for Pressure Sensitive Adhesive (PSA) Tapes Used in the Semiconductor Industry
New Evaluation Methods for Pressure Sensitive Adhesive (PSA) Tapes Used in the Semiconductor Industry by Tomoyuki Aogaki *, Hidefumi Miyagi * and Yoshihisa Kano * We propose new evaluation methods for
More informationExperiment 2b X-Ray Diffraction* Optical Diffraction Experiments
* Experiment 2b X-Ray Diffraction* Adapted from Teaching General Chemistry: A Materials Science Companion by A. B. Ellis et al.: ACS, Washington, DC (1993). Introduction Inorganic chemists, physicists,
More informationMagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study
MagSi Beads Magnetic Silica Beads for Life Science and Biotechnology study MagnaMedics Diagnostics B.V. / Rev. 9.2 / 2012 Wide range of products for numerous applications MagnaMedics separation solutions
More informationCharacterization of laser-material interaction during laser cladding process P.-A. Vetter,* J. Fontaine,* T. Engel," L. Lagrange,& T.
Characterization of laser-material interaction during laser cladding process P.-A. Vetter,* J. Fontaine,* T. Engel," L. Lagrange,& T. Marchione^ f^, BID de /a rzcfozre ^7000 France ABSTRACT The interaction
More informationSupporting Information
Supporting Information Fast-Response, Sensitivitive and Low-Powered Chemosensors by Fusing Nanostructured Porous Thin Film and IDEs-Microheater Chip Zhengfei Dai,, Lei Xu,#,, Guotao Duan *,, Tie Li *,,
More informationGE Healthcare Life Sciences. Biacore Assay Handbook
GE Healthcare Life Sciences Biacore Assay Handbook 1 Introduction 1.1 What Biacore systems measure... 5 1.2 Where Biacore systems are used... 5 1.3 Scope of this book... 6 1.4 Biacore system range...
More informationExcellent Plasma Control over Reactive Sputtering. Plasma Emission Controller
Excellent Control over Reactive Sputtering Emission Controller The superb feedback control of the reactive gas flow in a reactive sputtering process helps you enhance product quality and achieve greater
More informationMAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions
LAMBDA 265 / 365 / 465 UV/Vis Solutions MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE 2 PUTTING OUR FOCUS ON THE NEEDS OF INDUSTRY AND ACADEMIA Based on our long history of UV/Vis leadership, our LAMBDA
More informationPlasmonics: Application-oriented fabrication. Part 1. Introduction
Plasmonics: Application-oriented fabrication Part 1. Introduction Victor Ovchinnikov Department of Aalto Nanofab Aalto University Espoo, Finland Alvar Aalto was a famous Finnish architect and designer
More informationCBI Toolbox Tour 2015
CBI Toolbox Tour 2015 Thermophoresis (NanoTemper) NT.115 & NT.LabelFree Images: NanoTemper Circular Dichroism Jasco J-1500 Spectrometer Six Position Turreted Peltier Temperature Control System Automated
More informationIMP EPD End Point Detector
IMP EPD End Point Detector An overview of the Hiden Analytical SIMS end point detector system for ion beam etch applications IMP-EPD Presentation Topics The topics covered in the presentation include:
More informationGene Expression Technology
Gene Expression Technology Bing Zhang Department of Biomedical Informatics Vanderbilt University bing.zhang@vanderbilt.edu Gene expression Gene expression is the process by which information from a gene
More informationIntroduction to Biosensors. Prof. Xingwei Wang
Introduction to Biosensors Prof. Xingwei Wang 1 Brain Storm What do you think of biosensor? 2 Brain Storm What do you think of biosensor? 3 Significance & Great Demands Civil defense Food safety Criminology
More information4 Concept of Ripple Pyrometry during Flash Lamp Annealing
4 Concept of Ripple Pyrometry during Flash Lamp Annealing 4.1 Review on Temperature Measurement for Flash Lamp Annealing Several different efforts have been undertaken to measure temperature by contactless
More informationDirect genotyping of C3435T single nucleotide polymorphism in unamplified human MDR1 gene using a surface plasmon resonance imaging DNA sensor
Analytical and Bioanalytical Chemistry Electronic Supplementary Material Direct genotyping of C3435T single nucleotide polymorphism in unamplified human MDR1 gene using a surface plasmon resonance imaging
More informationOptical Components: Laser Crystals
Optical Components: Laser Crystals Table of Contents Crystals Introduction... 2 Nd: YVO 4... 3 Nd:YAG... 6 Nd:YLF... 7 Cr:YAG... 9 1 Crystals Introduction Sinoceramics supplies many types of crystals for
More informationFragment-based screening of enzyme drug targets: Microfluidic mobility shift assay improves confidence in candidate selection
Fragment-based screening of enzyme drug targets: Microfluidic mobility shift assay improves confidence in candidate selection Introduction Fragment-based lead discovery is establishing itself as valuable
More informationHPCE-5 2. A Revolution in Capillary Electrophoresis. High Performance Capillary Electrophoresis
A Revolution in Capillary Electrophoresis High Performance Capillary Electrophoresis Revolutionary Performance Continuous Monitoring of Capillary and Buffer Conditions Sensitive Label-Free 512 Times Better
More informationINSTRUMENTATION FOR A DISTRIBUTED FEEDBACK LASER BIOSENSOR SYSTEM ALLEN CHIA-YUAN CHU THESIS. Urbana, Illinois
INSTRUMENTATION FOR A DISTRIBUTED FEEDBACK LASER BIOSENSOR SYSTEM BY ALLEN CHIA-YUAN CHU THESIS Submitted in partial fulfillment of the requirements for the degree of Master of Science in Electrical and
More informationHermes Microvision, Inc.
Hermes Microvision, Inc. Investor Presentation February 2016 I. Introduction to HMI HMI Highlights Company Profile Leading-edge Inspection Tools and Solutions World s leading supplier of EBI tools and
More informationCoatings. Ion Assisted Deposition (IAD) process Advance Plasma Source (APS) plasma-ion assisted Deposition. Coatings on Optical Fibers
Anti-Reflection Custom Ion Assisted Deposition (IAD) process Advance Plasma Source (APS) plasma-ion assisted Deposition Anti-Reflection on Optical Fibers OptoSigma supplies a wide selection of optical
More informationSensor. Device that converts a non-electrical physical or chemical quantity into an electrical signal. Sensor Processor Display Output signal
Microsensors Outline Sensor & microsensor Force and pressure microsensors Position and speed microsensors Acceleration microsensors Chemical microsensors Biosensors Temperature sensors Sensor Device that
More informationPhotolithography I ( Part 2 )
1 Photolithography I ( Part 2 ) Chapter 13 : Semiconductor Manufacturing Technology by M. Quirk & J. Serda Bjørn-Ove Fimland, Department of Electronics and Telecommunication, Norwegian University of Science
More informationIn-Situ Characterization During MOVPE Growth of III-Nitrides using Reflectrometry
18 Annual Report 1999, Dept. of Optoelectronics, University of Ulm In-Situ Characterization During MOVPE Growth of III-Nitrides using Reflectrometry Christoph Kirchner and Matthias Seyboth The suitability
More informationMasayoshi Honda, Jeehae Park, Robert A. Pugh, Taekjip Ha, and Maria Spies
Molecular Cell, Volume 35 Supplemental Data Single-Molecule Analysis Reveals Differential Effect of ssdna-binding Proteins on DNA Translocation by XPD Helicase Masayoshi Honda, Jeehae Park, Robert A. Pugh,
More informationKinetics Review. Tonight at 7 PM Phys 204 We will do two problems on the board (additional ones than in the problem sets)
Quiz 1 Kinetics Review Tonight at 7 PM Phys 204 We will do two problems on the board (additional ones than in the problem sets) I will post the problems with solutions on Toolkit for those that can t make
More informationCharacterization of a human recombinant antibody fragment to be used in a diagnostic test
LABORATORY EXERCISE 1 Characterization of a human recombinant antibody fragment to be used in a diagnostic test Evaluation by SDS-PAGE, NanoDrop, ELISA, Biacore and Antibody microarray. Supervisors: Elin
More informationNIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production
NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production Slash release times with NIR Innovative features Fully automatic assay of tablet weight, hardness,
More information