CD34 Stem Cell Programme Sample All Participant Report. Date Issued - 06 March 2017 Closing Date - 24 March 2017 Machine Used - Facscanto II
|
|
- Branden Jefferson
- 5 years ago
- Views:
Transcription
1 Distribution CD3 Stem Cell Programme - 3 All Participant Report Participant ID - XXXX Date Issued - 6 March 17 Closing Date - March 17 Machine Used - Facscanto II Trial Comments This programme was issued to 37 participants. Comments The sample was manufactured by UK NEQAS using stabilised CD3+ samples and stabilised leucodepleted blood Absolute Values Results and Performance Please note: Performance monitoring for this programme is on absolute values only. Percentage results are shown for information purposes only. Your Results CD3 Absolute Values CD3 Absolute Values Results and Performance * Performance Status for this Performance Status Classification Over 1 Period Satisfactory Action Critical -.61 Satisfactory 1 Your Results % % % CD CD3 * Performance Status for this Performance Status Classification Over 1 Period Satisfactory Action Critical Satisfactory 1 * Limits Definitions Please note the scale below is applicable to the tables above and to the z score histograms and Shewhart control charts that follow. It is not applicable to the Cusum control charts. Absolute Percentage Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping. Page 1 of 11
2 CD3 Stem Cell Programme - 3 Histograms of Participant s Please note denotes your result Percentage of Returns 3 1 < (%) Please note denotes your result Percentage of Returns > < > Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping. Page of 11
3 CD3 Stem Cell Programme - 3 Shewhart Control Charts (Please note each data point represents a single sample) (%) Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping. Page 3 of 11
4 CD3 Stem Cell Programme - 3 Cusum Control Charts (Please note each data point represents the sum of the z scores of the current sample and the two previous samples) (%) Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping. Page of 11
5 Platform Specific Statistics (Please note only groups of > returns are displayed) CD3 Stem Cell Programme - 3 FLOW COUNT HAEMATOLOGY ANALYSER WBC TRUCOUNT Lysing Method Specific Statistics (Please note only groups of > returns are displayed) Ammonium Chloride (NHCL) Facslyse Pharmlyse Stem Kit Lyse Antibody Fluorochrome Specific Statistics (Please note only groups of > returns are displayed) PE Flow Cytometer Specific Statistics (Please note only groups of > returns are displayed) Facscalibur Facscanto II FC Navios Gating Strategy Specific Statistics (Please note only groups of > returns are displayed) BD STEM CELL ENUMERATION KIT ISHAGE STEM KIT Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping. Page 5 of 11
6 CD3 Stem Cell Programme - 35 Distribution Participant ID - XXXX Date Issued - 6 March 17 Closing Date - March 17 Machine Used - Facscanto II Trial Comments This programme was issued to 37 participants. Comments The sample was manufactured by UK NEQAS using stabilised CD3+ samples and stabilised leucodepleted blood Absolute Values Results and Performance Please note: Performance monitoring for this programme is on absolute values only. Percentage results are shown for information purposes only. Your Results CD3 Absolute Values CD3 Absolute Values Results and Performance * Performance Status for this Performance Status Classification Over 1 Period Satisfactory Action Critical. Satisfactory 1 Your Results % % % CD CD3 * Performance Status for this Performance Status Classification Over 1 Period Satisfactory Action Critical Satisfactory 1 * Limits Definitions Please note the scale below is applicable to the tables above and to the z score histograms and Shewhart control charts that follow. It is not applicable to the Cusum control charts. Absolute Percentage Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping. Page 6 of 11
7 CD3 Stem Cell Programme - 35 Histograms of Participant s Please note denotes your result Percentage of Returns 3 1 < (%) Please note denotes your result Percentage of Returns > < > Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping. Page 7 of 11
8 CD3 Stem Cell Programme - 35 Shewhart Control Charts (Please note each data point represents a single sample) (%) Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping. Page 8 of 11
9 CD3 Stem Cell Programme - 35 Cusum Control Charts (Please note each data point represents the sum of the z scores of the current sample and the two previous samples) (%) Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping. Page 9 of 11
10 Platform Specific Statistics (Please note only groups of > returns are displayed) CD3 Stem Cell Programme - 35 FLOW COUNT HAEMATOLOGY ANALYSER WBC TRUCOUNT Lysing Method Specific Statistics (Please note only groups of > returns are displayed) Ammonium Chloride (NHCL) Facslyse Pharmlyse Stem Kit Lyse Antibody Fluorochrome Specific Statistics (Please note only groups of > returns are displayed) PE Flow Cytometer Specific Statistics (Please note only groups of > returns are displayed) Facscalibur Facscanto II FC Navios Gating Strategy Specific Statistics (Please note only groups of > returns are displayed) BD STEM CELL ENUMERATION KIT ISHAGE STEM KIT Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping. Page 1 of 11
11 Information with respect to compliance with standards BS EN ISO/IEC 173:1.8. a) The proficiency testing provider for this programme is: UK NEQAS for Leucocyte Immunophenotyping Pegasus House, th Floor Suite 63A Glossop Road Sheffield, S1 QD United Kingdom Tel: + () , Fax: + () nicola.rose@ukneqasli.co.uk.8. b) The coordinators of UK NEQAS LI programmes are Prof David Barnett and Mr Liam Whitby..8. c) Person(s) authorizing this report: Prof David Barnett, Director or Mr Liam Whitby, Operations Manager of UK NEQAS LI.8. d) No activities in relation to this EQA exercise were subcontracted..8. g) The UK NEQAS LI Confidentiality Policy can be found in the Quality Manual which is available by contacting the UK NEQAS LI office. Participant details, their results and their performance data remain confidential unless revealed to the relevant NQAAP when a UK participant is identified as having performance issues..8. i) All EQA samples are prepared in accordance with strict Standard Operational Procedures by trained personnel proven to ensure homogeneity and stability. Where appropriate/possible EQA samples are tested prior to issue. Where the sample(s) issued is stabilised blood or platelets, pre and post stability testing will have proved sample suitability prior to issue..8. l), n), o), r) & s) Please refer to the UK NEQAS LI website at for detailed information on each programme including the scoring systems applied to assess performance (for BS EN ISO/IEC 173:1 accredited programmes only). Where a scoring system refers to the consensus result this means the result reported by the majority of participants for that trial issue. Advice on the interpretation of statistical analyses and the criteria on which performance is measured is also given. Please note that where different methods/procedures are used by different groups of participants these may be displayed within your report, but the same scoring system is applied to all participants irrespective of method/procedure used..8. m) We do not assign values against reference materials or calibrants..8. q) Details of the programme designs as authorized by The Steering Committee and Specialist Advisory Group can be found on our website at The proposed trial issue schedule for each programme is also available..8. t) If you would like to discuss the outcomes of this trial issue, please contact UK NEQAS LI using the contact details provided. Alternatively, if you are unhappy with your performance classification for this trial, please find the appeals procedure at Copy Report Issue Date: 9 Mar 17 ; Distribution: CD ; Version: 1.. Page 11 of 11 Sheffield Teaching Hospitals NHS Foundation Trust, a UKAS proficiency testing provider No. 78, operating UK NEQAS for Leucocyte Immunophenotyping.
JAK2 p.val617phe (V617F) Mutation Status
JAK2 p.val67phe (V67F) Mutation Status Distribution - 6702 Participant ID - Date Issued - 9 October 206 Closing Date - 8 November 206 Trial Comments In this trial, there were 25 participating laboratories;
More informationIgH/TCR Clonality Status. Performance Monitoring Cover Sheet. Final IgH Clonality Result IGH 131. Uncontrolled Copy
Performance Monitoring Cover Sheet Participant No: Trial No: IgH161703 Issue Date: 20 th December 2016 Performance Monitoring: Your Result N Consensus Clonality Result Final IgH Clonality Result IGH 131
More informationFEDERAL PUBLIC SERVICE, HEALTH, FOOD CHAIN SECURITY AND ENVIRONMENT CLINICAL BIOLOGY COMMISSION COMMITTEE OF EXPERTS GLOBAL REPORT
FEDERAL PUBLIC SERVICE, HEALTH, FOOD CHAIN SECURITY AND ENVIRONMENT CLINICAL BIOLOGY COMMISSION COMMITTEE OF EXPERTS GLOBAL REPORT EXTERNAL QUALITY ASSESSMENT IN CLINICAL BIOLOGY FLOW CYTOMETRY CD34+ STEM
More informationSCIENTIFIC INSTITUTE OF PUBLIC HEALTH QUALITY OF MEDICAL LABORATORIES CLINICAL BIOLOGY COMMISSION COMMITTEE OF EXPERTS GLOBAL REPORT
SCIENTIFIC INSTITUTE OF PUBLIC HEALTH QUALITY OF MEDICAL LABORATORIES CLINICAL BIOLOGY COMMISSION COMMITTEE OF EXPERTS GLOBAL REPORT EXTERNAL QUALITY ASSESSMENT IN CLINICAL BIOLOGY FLOW CYTOMETRY CD34+
More informationFEDERAL PUBLIC SERVICE, HEALTH, FOOD CHAIN SECURITY AND ENVIRONMENT CLINICAL BIOLOGY COMMISSION COMMITTEE OF EXPERTS GLOBAL REPORT
FEDERAL PUBLIC SERVICE, HEALTH, FOOD CHAIN SECURITY AND ENVIRONMENT CLINICAL BIOLOGY COMMISSION COMMITTEE OF EXPERTS GLOBAL REPORT EXTERNAL QUALITY ASSESSMENT IN CLINICAL BIOLOGY FLOW CYTOMETRY CD34+ STEM
More informationENUMERATION OF LYMPHOCYTES SUBSETS (IMMUNOPHENOTYPING-IPT) (CD3, CD4, CD8, CD19 & CD16/56)
Hospital Universiti Sains Malaysia for ENUMERATION OF LYMPHOCYTES SUBSETS (IMMUNOPHENOTYPING-IPT) (CD3, CD4, CD8, CD19 & CD16/56) Prepared by: Checked by: Approved by: En. Jamaruddin Mat Asan Date: Dr.
More informationImmunophenotyping of Peripheral Blood and Bone Marrow Cells by Flow Cytometry *Akanni EO and # Palini A.
Immunophenotyping of Peripheral Blood and Bone Marrow Cells by Flow Cytometry *Akanni EO and # Palini A. * Department of Haematology & Blood Transfusion,College of Health Science, Ladoke Akintola University
More informationHSC enumeration of fresh samples
HSC enumeration of fresh samples Claude LEMARIÉ QC Facility Medical Director Cell Therapy Facility, Centre de Thérapie Cellulaire, Département de Biologie du Cancer, Institut Paoli-Calmettes, Comprehensive
More informationPARTICIPANTS MANUAL. Point of Care RhD typing. UK NEQAS for Blood Transfusion Laboratory Practice
PARTICIPANTS MANUAL Point of Care RhD typing UK NEQAS for Blood Transfusion Laboratory Practice UK NEQAS (BTLP) PO Box 133 Watford WD18 0WP CONTENTS PAGE General Organisation of the Scheme 1-3 Location
More informationThe NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee
January, 1999 From: To: Subject: The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee NIAID DAIDS Flow Cytometry Laboratories Comparison study information for labs wishing to switch
More informationKit Contents FL-10 FL-12 FL-07 FL-09. Important: Before You Begin. New for this Mailing. Reporting Code Changes. Critical Reporting Information
FL-B 2014 Kit Instructions CAP 2014 Flow Cytometry Survey FL FL1 FL2 Table of Contents Kit Contents Kit Contents... 1 Important: Before You Begin... 1 Detailed Testing Instructions... 2 FL FL1 FL2 FL-07
More informationIdentification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer. Application Note
Identification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer Application Note Sylvie Veriac Valérie Perrone Madeleine Avon Abstract Agilent Equipment: 2100 bioanalyzer
More informationWADA Technical Document TD2019BAR. Blood Analytical Requirements for the Athlete Biological Passport
1. Introduction Blood Analytical Requirements for the Athlete Biological Passport This Technical Document (TD) has been established to harmonize the analysis of blood Samples collected, both In-Competition
More informationFINAL REPORT
PROFICIENCY TESTING PROGRAM FOR TENSILE PROPERTIES OF STEEL [PTM/MECH/10/14-15] FINAL REPORT 2015-16 ORGANIZED BY GLOBAL PT PROVIDER PVT. LTD., NEW DELHI PT SCHEME NAME : TENSILE PROPERTIES OF STEEL PT
More informationWEQAS: what is it and what does it mean?. Celia Critchley Point of Care Co-ordinator Warrington and Halton Hospitals NHS Foundation Trust
WEQAS: what is it and what does it mean?. Celia Critchley Point of Care Co-ordinator Warrington and Halton Hospitals NHS Foundation Trust Objectives Overview of External Quality Assessment and its relevance
More informationPERFECT-COUNT MICROSPHERES
PERFECT-COUNT MICROSPHERES Perfect-Count Microspheres-Product code PCB-100 for 100 tests Introduction In recent years, the determination of absolute cell counts has been shown to be relevant in different
More informationQuality Control and Assessment in Flow Cytometry
Quality Control and Assessment in Flow Cytometry D. Barnett 1 & Teri Oldaker 2 UK NEQAS for Leucocyte Immunophenotyping 1 & Flow Cytometry Genoptix Medical Laboratory 2 1 Quality Control in Flow Cytometry
More informationPoor Performance Criteria for the UKNEQAS Molecular Rapid Aneuploidy (MRA) External Quality Assessment (EQA) scheme
Document Control Version: 5.0 Document Authors: Drs Sandi Deans & Ros Hastings Date: 30 th April 2013 Date of ratification by MRA SAG: Molecular & Cytogenetic: 22 nd January 2013 Date of agreement by NQAAP:
More information2. SUMMARY AND EXPLANATION
English Stem-Trol Control Cells 1-10 1. INTENDED USE 2 2. SUMMARY AND EXPLANATION 2 3. PRINCIPLE OF TEST 2 4. REAGENT CONTENTS 2 5. STATEMENT OF WARNINGS 2 6. STORAGE CONDITIONS AND STABILITY 3 6.1 Evidence
More informationBorrelia burgdorferi
Borrelia burgdorferi 2013 EQA Programme Final Report QAB114147 (BbDNA13) Dr Volker Fingerle Scientific Expert on behalf of QCMD Report authorised by the QCMD Executive in February 2014 A UKAS accredited
More informationRules for accreditation of providers of proficiency testing/interlaboratory
Rules for accreditation of providers of proficiency testing/interlaboratory tests Scope: With this regulation the requirements for accreditations of providers of proficiency testing/interlaboratory tests/ring
More informationFINAL REPORT
PROFICIENCY TESTING PROGRAMME FOR CHEMICAL TESTING OF STEEL ALLOY [PTM/CHEM/02/14-15] FINAL REPORT 2014-15 ORGANIZED BY GLOBAL PT PROVIDER PVT. LTD., NEW DELHI PT SCHEME NAME : CHEMICAL TESTING OF STEEL
More informationMonitoring Quick Guide 3
Monitoring Quick Guide 3 version 1.0 SM-QG3 - Applying BS EN 14181 Stationary Source Emissions; Quality assurance of automated measuring systems 1. Scope This Quick Guide describes the requirements for
More informationFINAL REPORT
PROFICIENCY TESTING PROGRAMME FOR CHEMICAL TESTING OF ZINC ALLOY [PTM/CHEM/04/14-15] FINAL REPORT 2015-16 ORGANIZED BY GLOBAL PT PROVIDER PVT. LTD., NEW DELHI PT SCHEME NAME : CHEMICAL TESTING OF ZINC
More informationInter-laboratory Comparisons (ILC) Detailed Information (Calibration Laboratories)
National Laboratory Association Association Incorporated under Section 21 Not for Gain) P.O. Box 298 Persequor Park Pretoria, South Africa, 0020 Reg. No: 1994/002856/08 Tel: (+27) 012 349 1500 Fax: (+27)
More informationthe world s best spline gauges and master gears
the world s best spline gauges and master gears Frenco International are world leaders in the manufacture of spline plug and ring gauges, for involute, serration and straight sided splines, also master
More informationProficiency Testing. Protocol. Organisation and Analysis of Data
Proficiency Testing Protocol Organisation and Analysis of Data Third Edition, September 2002 FOOD EXAMINATION PERFORMANCE ASSESSMENT SCHEME (FEPAS ) PROTOCOL FOR THE ORGANISATION AND ANALYSIS OF DATA THIRD
More informationBD FACSCalibur. The flow cytometer for your routine cell analysis needs
BD FACSCalibur The flow cytometer for your routine cell analysis needs A system with a rich application basis and a modular approach that continues to meet evolving needs of cell analysis worldwide. The
More informationNavios EX FLOW CYTOMETER POWERFUL, DEPENDABLE FLOW CYTOMETRY
Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE FLOW CYTOMETRY BECAUSE EVERY EVENT MATTERS The Navios EX flow cytometer offers a solution for advanced cytometry applications with optimized workflows for
More informationBD Stem Cell Enumeration Application Guide
BD Stem Cell Enumeration Application Guide for BD FACSCalibur Flow Cytometers IVD For In Vitro Diagnostic Use bdbiosciences.com 23-11206-01 Rev. 01 12/2011 Becton, Dickinson and Company BD Biosciences
More informationGeneral Protocol. SENATE Microbiological Proficiency Testing Schemes
SENATE Microbiological Proficiency Testing Schemes General Protocol Bio Senate Ltd. Unit 12B, Britannia Mill, Cobden Street, Bury, Lancashire, BL9 6AW, UK. Telephone: + 44 (0) 161 764 4998 Fax: + 44 (0)
More informationWhole Blood Leukocytes Isolation with Microfabricated Filter for Cell Analysis
Technical Note Whole Blood Leukocytes Isolation with Microfabricated Filter for Cell Analysis Liping Yu, 1 * Patrick Warner, 2 Brian Warner, 1 Diether Recktenwald, 1 Douglas Yamanishi, 3 Antonio Guia,
More informationJMSCR Vol 07 Issue 01 Page January 2019
www.jmscr.igmpublication.org ISSN (e)-2347-176x ISSN (p) 2455-0450 DOI: https://dx.doi.org/10.18535/jmscr/v7i1.101 Absolute CD34+ Cell Count by Flow Cytometry at M.Y. Hospital Indore Authors Prof. Dr C.V.
More informationUK NEQAS FOR BLOOD COAGULATION: Programmi EQAS nel laboratorio di coagulazione
UK NEQAS FOR BLOOD COAGULATION: Programmi EQAS nel laboratorio di coagulazione Tim Woods, Manager UK NEQAS for Blood Coagulation STH Royal Hallamshire Hospital Sheffield U.K. www.ukneqasbc.org Quality
More informationMonitoring Assay Traceability through EQAS Surveillance
FOR CLINICAL CHEMISTRY UNITED KINGDOM NATIONAL EXTERNAL QUALITY ASSESSMENT SCHEMES Monitoring Assay Traceability through EQAS Surveillance AACC Edutrak 3305, Orlando, 30 July 2002 Dr David G Bullock Director,
More informationGuidelines for the assessment of the appropriateness of small interlaboratory comparisons within the process of laboratory accreditation
Publication Reference EA-4/21 INF: 2018 Guidelines for the assessment of the appropriateness of small interlaboratory comparisons within the process of laboratory accreditation PURPOSE This paper provides
More informationMSc in Transfusion and Transplantation Sciences
MSc in Transfusion and Transplantation Sciences School of Cellular & Molecular Medicine Prof Marion Scott, Teaching Board Member 1 1 year full-time specialised MSc, or 2-3 year part-time The full-time
More informationEstablishing Competency of Staff in Flow Cytometry. and achieve ISO standard
Establishing Competency of Staff in Flow Cytometry and achieve ISO standard 5.1.6. Andrew Moran Chief Biomedical Scientist Dept of Immunology Manchester Royal Infirmary Immunology at MRI CD4 counts T,
More informationQuality Control in polychromatic Flow Cytometry - EuroFlow interlaboratory standardization
IV. International Symposium Flow Cytometry/Molecular Biology HOSPITAL ISRAELITA ALBERT EINSTEIN São Paulo 2012 Quality Control in polychromatic Flow Cytometry - EuroFlow interlaboratory standardization
More informationACTG Laboratory Technologist Committee Revised Version 2.0 ACTG Lab Man CD38 Quantitation 07 May 2004
1. Principle Flow Cytometric quantitation of CD38 expression on CD8+ T lymphocytes The purpose of this assay is to quantitate the surface expression of the CD38 molecule on CD8 positive T lymphocytes.
More informationNavios EX FLOW CYTOMETER POWERFUL, DEPENDABLE CLINICAL FLOW CYTOMETRY
Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE CLINICAL FLOW CYTOMETRY BECAUSE EVERY EVENT MATTERS The Navios EX flow cytometer offers a solution for advanced cytometry applications optimized for the clinical
More informationISO INTERNATIONAL STANDARD. Statistical methods for use in proficiency testing by interlaboratory comparisons
INTERNATIONAL STANDARD ISO 13528 First edition 2005-09-01 Statistical methods for use in proficiency testing by interlaboratory comparisons Méthodes statistiques utilisées dans les essais d'aptitude par
More informationEstimating potency of cord blood transplants: Current standards and challenges
Cord Blood Infusions: Current Gold Standards in Preparing and Testing of Cord Blood Products for Transplantation Estimating potency of cord blood transplants: Current standards and challenges Teja Falk
More informationTOYTEST - Toy Safety Analytes Proficiency Scheme Report Round: 51 Group: Flux testing
TOYTEST - Toy Safety Analytes Proficiency Scheme Report Group: Flux testing Issue Number 1 Issued 01 October 2012 LGC Standards Proficiency Testing 1 Chamberhall Business Park, Chamberhall Green, Bury
More informationDiagnostic Medical Equipment New Revenue for Your Medical Practice
Diagnostic Medical Equipment New Revenue for Your Medical Practice Consultant Libby Knollmeyer s Lab Machine Primer Series Part 1: Hematology Analyzers When laboratories in physician offices move out of
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Royal Liverpool and Broadgreen University Hospitals NHS Trust Liverpool Clinical Laboratories (LCL) Department of Histocompatibility and Immunogenetics
More informationAPLAC T098 Proficiency Testing Programme Determination of Migration of Heavy Metals in Toys Coating. APLAC Proficiency Testing Program APLAC T098
APLAC T098 Proficiency Testing Programme Determination of Migration of Heavy Metals in Toys Coating APLAC Proficiency Testing Program APLAC T098 Determination of Migration of Heavy Metals in Toys Coating
More informationISO/IEC Conformity assessment General requirements for proficiency testing
ISO/IEC 17043 Conformity assessment General requirements for proficiency testing 6 th th Eurachem Workshop 7 October, 2008 Daniel Tholen, M.S. A2LA, APLAC, ILAC Background: ISO/IEC 17043 Work Work Proposal
More informationQuality Control in Flow. Dr David Westerman Head of Haematopathology Peter MacCallum Cancer Centre
Quality Control in Flow Dr David Westerman Head of Haematopathology Peter MacCallum Cancer Centre Aims Quality Assurance Quality Control Literature In house competencies SHOT DATA 1996-2009 Ref: SHOT Annual
More informationChallenges for Product Evaluation by Flow Cytometry for Cellular Therapy Product Processing Laboratories
Challenges for Product Evaluation by Flow Cytometry for Cellular Therapy Product Processing Laboratories C A R O LY N A. K E E V E R - TAY L O R, P H D M E D I C A L C O L L E G E O F W I S C O N S I N
More informationProtocol Page 1 of 11. Protocol for Proficiency testing scheme for Bitumen Programme No. GPTS/PT 05
Tel Nos. +91 79 2656 5405, 2656 1104, Mob Nos. +91 98254 13148, 93270 17517, Fax Nos. +91 79 2656 3240 Email sales@globalptservices.com, nilesh@globalptservices.com Protocol Page 1 of 11 Protocol for Proficiency
More informationPoint of Care Testing in Clinical Trials
Point Of Care Testing in Clinical Trials Page 1 Point of Care Testing in Clinical Trials Point of Care Testing Point of care (POC) testing is diagnostic testing performed promptly and conveniently in the
More informationEstablishment of an Accredited Reference Measurement Laboratory
Establishment of an Accredited Reference Measurement Laboratory Francesco Dati, PhD IVD-Consulting Marburg / Germany E-mail: f.dati@t-online.de Quality of Analytical Systems Reference Measurement Systems
More informationBD FACSCanto II Flow Cytometry System
Regional Offices Asia Pacific BD Singapore Tel 65.6861.0633 Fax 65.6860.1593 Australia/New Zealand Australia Toll Free: 1800 656 100 Tel 61.2.8875.7000 Fax 61.2.8875.7200 bd_anz@bd.com New Zealand Toll
More informationPage 1 of 59 Version 5 Effective Date 07/11/16
PARTICIPANT MANUAL 2017 CONTENTS Page 1. Introduction 2 2. Aims of and Participation in the Scheme 2 3. Participant Manual 3 4. Contact Details 3 5. Contact with UK NEQAS for H&I 3 6. Complaints 4 7. Confidentiality
More informationGLP/SC/01 Basic statistical tools for analytical chemistry (2 days)
GLP Consulting http://consultglp.com Courses on offer (See outlines below) GLP/SC/01 Basic statistical tools for analytical chemistry (2 days) GLP/SC/02 The GUM bottom-up evaluation technique of measurement
More informationTherapeutic Apheresis Services. Annual Review 2015/16
Therapeutic Apheresis Services Annual Review 2015/16 1 OVERVIEW NHS Blood and Transplant (NHSBT) is a major provider of Therapeutic Apheresis Services (TAS) in the NHS. At the end of each financial year,
More informationRULES FOR THE PARTICIPATION IN INTER- LABORATORY COMPARISONS AND PROFICIENCY TESTING SCHEMES
RULES FOR THE PARTICIPATION IN INTER- LABORATORY COMPARISONS AND PROFICIENCY TESTING SCHEMES Reviewed by: Radivoje Nikoličić Quality Manager (QM) Approved by: Prof. Aco Janićijević, PhD Acting Director
More informationImmunophenotyping, Sheffield S10 2JF, UK 3 Department of Flow Cytometry, Maryam Saber Genoptix Medical Laboratory, Carlsbad, California
Cytometry Part B (Clinical Cytometry) 94B:67 81 (2018) Original Article ICCS/ESCCA Consensus Guidelines to detect GPI-deficient cells in Paroxysmal Nocturnal Hemoglobinuria (PNH) and related Disorders
More informationSupplementary Figure 1 (Page1)
Supplementary Figure 1 (Page1) A B FSC-A 45 Fitc-A 133 APC-A 19 APC-Cy7-A 34 PE-A 45 Fitc-A FSC-A 45 Fitcs-A C 38 PE-Cy7-A 45 Fitc-A 45 Fitc-A 7AAD FSC-A Supplementary Figure 1 (Page2) D (1) (6) (2) (3)
More informationBEIPH Final Report. EQA Programme 2011 Hepatitis B Virus (HBVDNA11A) William G Mackay on behalf of QCMD and its Scientific Council July 2011
BEIPH Final Report EQA Programme 2011 Hepatitis B Virus (HBVDNA11A) William G Mackay on behalf of QCMD and its Scientific Council July 2011 Not to be reproduced or quoted without permission of QCMD. Any
More informationDetails: Approval: Distribution & Storage:
Details: Author: Neville Young Quality Assurance Manager SOP Pages: Version No. of replaced SOP: Effective date of replaced SOP: NA NA Approval: Version No: of the SOP being approved. Name of person approving
More informationThe RT-qPCR analysis of selected type-i IFNs related genes, IRF7 and Oas3. The
SUPPLEMENTARY MATERIALS AND METHODS Real time quantitative PCR The RT-qPCR analysis of selected type-i IFNs related genes, IRF7 and Oas3. The RT-qPCR was performed on the Applied Biosystems StepOne TM
More informationTOYTEST. Scheme Description. Toy Safety Analytes Proficiency Testing Scheme
TOYTEST Toy Safety Analytes Proficiency Testing Scheme Scheme Description LGC Standards Proficiency Testing 1 Chamberhall Business Park Chamberhall Green Bury Lancashire BL9 0AP United Kingdom Telephone:
More informationSysmex Educational Enhancement and Development No
SEED Haematology Sysmex Educational Enhancement and Development No 2 2015 SNCS the quality control solution for the haematology laboratory The purpose of this newsletter is to provide an overview of the
More informationThe role of accreditation bodies and EQA organisers in the. specifications
The role of accreditation bodies and EQA organisers in the assessment of analytical quality specifications Ian Mann Swiss Accreditation Service ian.mann@sas.ch Content Important partners and aspects of
More informationRobert Elshaw Transfusion Manager Hull and East Yorkshire Hospitals NHS Trust
Robert Elshaw Transfusion Manager Hull and East Yorkshire Hospitals NHS Trust Duty of care for patient (gate keeping) Professional requirement to support the clinical team Provide major input into Trust
More informationAnnual Report UK NATIONAL EXTERNAL QUALITY ASSESSMENT SCHEME for Feto-Maternal Haemorrhage. UK NEQAS (FMH) PO Box 1000 Watford WD18 0WP
Annual Report 2015 UK NATIONAL EXTERNAL QUALITY ASSESSMENT SCHEME for Feto-Maternal Haemorrhage UK NEQAS (FMH) PO Box 1000 Watford WD18 0WP UK NEQAS (FMH) 2016 INDEX Page Number 1 INTRODUCTION 1 2 THE
More informationBEIPH Final Report. QCMD 2009 Hepatitis C virus (HCVRNA09) EQA Programme
QUALITY CONTROL for MOLECULAR DIAGNOSTICS Block 4, Kelvin Campus, West of Scotland Science Park, Glasgow, G SP Scotland Tel: +44 () 4 945 6474 Fax: +44 () 4 945 5795 www.qcmd.org info@qcmd.org BEIPH Final
More informationNavios Now Because Every Event Matters
Navios Now Because Every Event Matters Powerful, Dependable 10-Color Flow Cytometry Because we understand the power inside every cell, we designed the Navios flow cytometer to capture the information you
More informationAMBIENT DUST MONITORING REPORT
AMBIENT DUST MONITORING REPORT 2-4 Langlands Place Kelvin South Business Park East Kilbride G75 0YF Tel: 01355 246 730 Fax: 01355 249 669 Your contact at ESG David Hay Business Manager - North Tel: 01355
More informationSchedule of Accreditation
Schedule of Accreditation Organisation Name INAB Reg No Contact Name Address West North West Hospitals Group Galway University Hospital Dept Haematology 239MT Mary Kilcooley Contact Phone No 091 544419
More informationChallenges for Flow Cytometry in Regulated Bioanalysis
Challenges for Flow Cytometry in Regulated Bioanalysis Minesh Patel Merck Millipore Discovery & Development Solutions. Oxford, UK. Overview Flow cytometry principles Current uses and regulatory environments
More informationPROFICIENCY TESTS PROTOCOL. Document valide au 21/02/2018. Editor: Marie-Phillipe SEILLER
PROFICIENCY TESTS PROTOCOL Editor: Marie-Phillipe SEILLER This booklet gives information about the design of proficiency tests offered by BIPEA. For any further information, please feel free to contact
More informationFlow Cytometry. Principles and Applications. Edited by. Marion G. Macey, PhD
Flow Cytometry Flow Cytometry Principles and Applications Edited by Marion G. Macey, PhD Department of Haematology The Royal London Hospital London, United Kingdom 2007 Humana Press Inc. 999 Riverview
More informationISO/IEC INTERNATIONAL STANDARD. Conformity assessment General requirements for proficiency testing
INTERNATIONAL STANDARD ISO/IEC 17043 First edition 2010-02-01 Conformity assessment General requirements for proficiency testing Évaluation de la conformité Exigences générales concernant les essais d'aptitude
More informationSelecting Reagents for Multicolor Flow Cytometry
HotLines Platinum Edition f a l l 0 0 6 Selecting Reagents for Multicolor Flow Cytometry By Holden Maecker and Joe Trotter The availability of flow cytometers capable of detecting 6, 8, and more colors
More informationNiMS. Scheme Description. Nickel Migration Proficiency Testing Scheme
NiMS Nickel Migration Proficiency Testing Scheme Scheme Description LGC Standards Proficiency Testing 1 Chamberhall Business Park Chamberhall Green Bury Lancashire BL9 0AP United Kingdom Telephone: +44
More informationWHO Manual Organizing a National External Quality Assessment Programme for Health Laboratories and other Testing Sites
WHO Manual Organizing a National External Quality Assessment Programme for Health Laboratories and other Testing Sites Willy Urassa Prequalification of In Vitro Diagnostics (IVDs) Essential Medicine and
More information- - - Backup_Lab_Guidelines v
- - - Backup_Lab_Guidelines v2.0 2010-11-10 Table of Contents Introduction... 1 Back-Up Guidelines for Safety Testing Laboratories... 2 Introduction... 2 Development and review of the back-up plan... 2
More informationApplication Information Bulletin: DuraClone IM Tubes Compensation setup for high content DuraClone reagents
Application Information Bulletin: DuraClone IM Tubes Compensation setup for high content DuraClone reagents Compensation setup for high content DuraClone reagents INTRODUCTION High content flow cytometry
More informationSAMPLE. Enumeration of Immunologically Defined Cell Populations by Flow Cytometry; Approved Guideline Second Edition
May 2007 Enumeration of Immunologically Defined Cell Populations by Flow Cytometry; Approved Guideline Second Edition This document provides guidance for the immunophenotypic analysis of non-neoplastic
More informationUK NEQAS for Cellular Pathology Technique. Participant Manual (Edition 14)
UK NEQAS for Cellular Pathology Technique Participant Manual 2016-17 (Edition 14) Providing worldwide external quality assessment and proficiency testing for all aspects of tissue diagnostics www.ukneqascpt.org.uk
More informationExamination of the feasibility of establishing a peer reviewed external quality assessment scheme for red blood cell antibody eluate investigations
Examination of the feasibility of establishing a peer reviewed external quality assessment scheme for red blood cell antibody eluate investigations Janet Murphy, Dublin Institute of Technology. John Crumlish,
More informationHYGIENE. Scheme Description. Environmental Hygiene Monitoring PT Scheme. LGC Standards S.L.U. C/Salvador Espriu 59 2º Barcelona Spain
HYGIENE Environmental Hygiene Monitoring PT Scheme Scheme Description LGC Standards S.L.U. C/Salvador Espriu 59 2º 08005 Barcelona Spain Tel: +34 93 308 41 81 Fax: +34 93 307 36 12 Email: es@lgcgroup.com
More informationBD FACSCanto II. A proven research platform for maximum reliability and the highest quality results
BD FACSCanto II A proven research platform for maximum reliability and the highest quality results A proven platform for maximum reliability and the highest quality results Built on more than 25 years
More informationa Beckman Coulter Life Sciences: White Paper
a Beckman Coulter Life Sciences: White Paper Long Term Stabilization of Tandem Dyes for Use in High Content, Multi Variant Flow Cytometry Authors: Snehita Sattiraju 1, Tewfik Miloud 2, Neha Girish 1, Murthy
More informationNovoCyte Flow Cytometer
NovoCyte Flow Cytometer The Flow Cytometer for Everyone 2 Experience the NovoCyte Advantage Focus on advancing your research. Let the flow cytometer do the rest. NovoCyte Flow Cytometer High Performance
More informationFlow Cytometry in the Diagnosis of Hematopoietic Neoplasia. Brent Wood MD, PhD Professor, Laboratory Medicine University of Washington, Seattle
Flow Cytometry in the Diagnosis of Hematopoietic Neoplasia Brent Wood MD, PhD Professor, Laboratory Medicine University of Washington, Seattle 1 Flow Cytometer 2 The Power of Flow Cytometry Single cell
More informationFinding the Bugs through EQA
Finding the Bugs through EQA UK NEQAS for Microbiology Shân Lloyd, Vivienne James, Christine Walton The Traditional Benefits Provides insight into laboratory performance Checks efficacy of internal quality
More informationHYGIENE. Scheme Description. Environmental Hygiene Monitoring PT Scheme
HYGIENE Environmental Hygiene Monitoring PT Scheme Scheme Description LGC Standards Proficiency Testing 1 Chamberhall Business Park Chamberhall Green Bury, BL9 0AP UK. Telephone: +44 (0) 161 762 2500 Fax:
More informationBirmingham Quality Participants Manual
Birmingham Quality Participants Q-WKS-001B 3 Refer to Q-Pulse 17/06/2018 1 of 31 Contents 1. General Information... 5 1.1. Background... 5 1.2. Aims... 5 1.3. UK NEQAS Code of Practice... 5 1.4. Location...
More informationFIRMS. Scheme Description. Forensic Isotope Ratio Mass Spectrometry Scheme
FIRMS Forensic Isotope Ratio Mass Spectrometry Scheme Scheme Description LGC Standards Proficiency Testing 1 Chamberhall Business Park Chamberhall Green Bury Lancashire BL9 0AP United Kingdom Telephone:
More informationHardness Testing of Metals Proficiency Testing Program Round 8
REPORT NO. 916 Hardness Testing of Metals Proficiency Testing Program Round 8 June 2015 ACKNOWLEDGMENTS PTA wishes to gratefully acknowledge the technical assistance provided for this program by Mr G Pownall,
More informationSEED HAEMATOLOGY. SNCS IQAS Online the quality control solution for the haematology laboratory
SYSMEX EDUCATIONAL ENHANCEMENT AND DEVELOPMENT NOVEMBER 2015 SEED HAEMATOLOGY SNCS IQAS Online the quality control solution for the haematology laboratory Introduction It is standard practice for laboratories
More informationASSESSMENT OF CLINICAL FLOW CYTOMETRY LABORATORY PRACTICE. First Edition Australasian Cytometry Society Laboratory Assessment Document
ASSESSMENT OF CLINICAL FLOW CYTOMETRY LABORATORY PRACTICE First Edition 2018 Australasian Cytometry Society Laboratory Assessment Document Paper-based publications This work is copyright. You may reproduce
More informationBD Multicolor CompBeads
4/2015 23-9955-01 IVD BD Multicolor CompBeads 100 compensation setups Catalog No. 644204 BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. 2015 BD Becton, Dickinson and
More informationBD FACSMelody. Cell Sorter. The simple solution for consistent, quality results
BD FACSMelody Cell Sorter The simple solution for consistent, quality results The right instrument is needed for the best results Simplicity, affordability and quality are key Cell sorting is fast becoming
More informationTOYTEST. Scheme Description. Toy Safety Analytes Proficiency Testing Scheme
TOYTEST Toy Safety Analytes Proficiency Testing Scheme Scheme Description LGC Standards Proficiency Testing 1 Chamberhall Business Park Chamberhall Green Bury Lancashire BL9 0AP United Kingdom Telephone:
More information18/08/2011. Principles of Flow Cytometry (Practised in a Clinical Laboratory) Cytometer Components. Noel Williams Immunobiology Division of Immunology
Optical Measurement Principles Principles of Flow Cytometry (Practised in a Clinical Laboratory) Noel Williams Immunobiology Division of Immunology Cytometer Components Reagents Cytometer Setup Cytometer
More information