CISA Reprocessing Systems

Size: px
Start display at page:

Download "CISA Reprocessing Systems"

Transcription

1 CISA Reprocessing Systems ERS Endoscope Reprocessing and Storage System Feel the innovation 0123

2 ERS/ESS An innovative approach to the treatment, reprocessing, and aseptic storage of endoscopes and other medical equipment Feel the innovation

3 ERS Endoscope Reprocessing System The challenge of controlling cross-contamination in hospitals has been attracting increased attention. Health services are investing increasing sums to decrease the risk of possible crosscontamination, and thereby decrease the risk of contracting a Hospital Acquired Infection. Endoscopy is an area that has received particular attention, partly because of the number of uses of an endoscope in a day, and partly because the cost of an endoscope means that a long life is expected of it. To protect the patient, there is a demand for fast and effective disinfection between uses. Engineers have been looking at ways and means for continued improvements both in the design of washer disinfectors and in the chemical washing and disinfecting agents. Bearing in mind these requirements, a modular system for the various stages of endoscope reprocessing, including storage, which also makes the process easier, safer, and reproducible, would help to meet these needs. CISA has carried out a programme of research and development ending in the production of a system that washes, decontaminates, even exceeds high level disinfection, and provides aseptic storage of flexible and rigid endoscopes, named ERS/ ESS: The Endoscope Reprocessing and Storage System. The element at the centre of the whole process is revolutionary, and at the same time very simple: a cassette in which a contained endoscope is enclosed through the disinfection process, drying, and storage, and until required for the next use without any further exposure to the outside world and its risks of cross-contamination. Operating Cycle The ERS has been designed to meet and exceed the usual levels of high disinfection (over log 7 kill rate) with the reprocessing of endoscopes within less than 45 minutes. The distribution of the chemicals in the cassettes has been designed to guarantee their efficacy both inside and outside the separate channels that make up an endoscope. A group of sensors monitors the required flow of each liquid through each channel during each phase of the cycle. The ERS has been designed so that the reprocessing of two separate cassattes can be carried out independently. The processing is all carried out at room temperature. The cassatte provides aseptic storage and transportation of the processed endoscopes. The ERS will only operate each phase of the cycle (see page 6) when each phase s - check criteria have been met. Innovative system for Endoscope reprocessing: Cleaning, Bio Film Removal, Treatment exceeding high level disinfection involves the following steps. Cleaning Rinse Processing Final rinse Continuous leak test Channel monitoring Alcohol purge Bio Film removal Using sterile water and sterile air Endoscope reprocessing with a log 7 reduction of bacteria Using sterile water and sterile air inside the channels At the start of the cycle and during all cycle phases, a continuous leak test is performed All internal channels are monitored continuously for channel obstruction This option that can be provided at the end of the cycle Touch screen control and display Channel monitoring Function monitoring Ers 3

4 ERS Endoscope Reprocessing System Pre-Treatment and Treatment Chemicals The ERS System uses Proteazone-ERS manufactured to obtain proper cleaning (including removal of bio film) and a cold sterilizing solution, Adaspor-ERS single shot for reaching greater than the high level of disinfection. Bacteriologically-filtered water (or external RO water) guarantees the quality of the final rinse, while sterile compressed air dries the channels. Cold sterilizing solution Adazone (5,7-diphenyl-1,3 diazoadamantan-6-one) g. 0, peracetic acid g. 0,085 - coformulants purified H2O at ml. 100 Decontaminating concentrate Adazone L g. 2,50-germicidal complex surfactant with linear structure (R=C10:C14) g. 60,50- coformulants and purified H2Oat ml. 100 Biological and Chemical Tests CISA offers a complete set of quality control tests using biological and chemical indicators, designed specially for the CISA ERS. BOX Clamp Media Strip ERS - Biological Test Sterile Air & water Air exchange filter (0.2 micron) for Cassettes Compressed air control valves (6-8 bar and 0.5 bar with absolute filters 0.2 micron air filters. Cassette 1 Cassette 2 Water Filter 1 (5 micron) Water Filter 2 (0.5 micron) Water Filter 3 (0.1 micron) Chemical container 1 (isopropyl alcohol or secondary disinfectant) Chemical container 2 (Proteazone-ERS) Chemical container 3 (5% peracetic acid) Chemical container 4 (Adazone-ERS buffer) 4 Ers

5 ERS Endoscope Sterile Storage System Storage and Drying The ERS System is made up of two machines, the first, the ERS, designed to decontaminate, and the second, the ESS, designed for the aseptic storage of the endoscopes in their cassettes. The ESS storage unit for storing endoscopes and drying them is easy to use, and is fast and effective. The ESS will take up to six cassettes at a time: each one is monitored individually and constantly as warm sterile air is blown through each internal channel and across the external surface of the scope, to remove any trace of water. This process allows storage of endoscopes that are ready for use for at least 72 hours after reprocessing and storage without the need to reprocess again within this period which increases endoscope shelf life and thereby reduces unnecessary costs. Increased shelf life The ESS unit offers sterile storage shelf life 72 hours without the need for reprocessing. Many studies carried out that even more than 72 hours for scope to be used without reprocessing are enough using unique CISA storecase ESS system. Chemical cost saving As the standard world wide instruct to reprocess the scope after 4 hours of reprocessing time even if not used if using regular drying cabinets and open endoscopes. With CISA storecase and ESS, the holding time will increase to 72 hours which will safe a lot of chemical cost and make the scope safe to use. CISA ESS is the cost effective solution with cutting unnecessary reprocessing and chemical waste. Changes color to brilliant green at the end of the cycle. Total time of introduction of the Store-case in the ESS. Lock/Unlock Store-Case button. Check LED of correct insertion of the Store-Case inside the ESS. Air temperature in output from the Store-Cases. Pressure of the air in input of the Store-Cases. Selection button to access the ordinary maintenance page. Visualize the Inserted Store-Cases. Visualize the pressure of the air in input. Back to the previous page. Visualize the temperature in Input. Visualize the temperature in Output. Ers 5

6 ERS Endoscope Reprocessing and Storage System Store Case The store-case is the biggest innovation in the ERS system. It allows the handling, storage, and management of both rigid and flexible endoscopes without risk of their being crosscontaminated. The store-cases are made of specialised materials to prevent damage from chemicals, or leakage, with the help of silicon gaskets. The channel connectors are sealed from the external environment by auto-seal attachments. The store-case plastic is light, chemical resistant, transparent, and non-deformable. Its inner surface is smooth and rounded for optimal drainage. Furthermore, the store-case s inner shape and configuration makes it fully compatible with every make of endoscope. A hermetic seal is guaranteed, and tamper-proof security tags provide visual confirmation that the store-case has net been opened since reprocessing. Each store-case can have its own microchip transponder which communicates with the ERS and ESS relevant data relating to the instrument inside, the operator, the reprocessing cycle employed, etc... providing for full tracking and traceability. Easy To Use The ERS system has been designed for maximum ease of use, thanks in great part to the flexibility of the store-case principle. The only manual operation, after the endoscope has been placed in the Cassette, is to introduce the Cassette in the ERS or ESS. All of the other operations are automatic, including channel connection and disconnection. The operator controls the reprocessing procedure through a touch screen, where the progress of the cycle and all security checks can be monitored. Safety The processing and preserving machines have been projected under every safety criterion, so they have the necessary protections for the patients, the operators, the instruments and the environment. The Endoscope Reprocessing and Storing System is a new generation equipment and satisfy every safety application. Thanks to this kind of reprocessing, the safety of the patients with No-diffusion of infections is guaranteed. The cycle is totally automatic and it doesn t need any operator action. The operator has just to introduce the endoscope in the Store case, than the Store case in the machine. The reprocessing is guaranteed by a cold sterile solution, absolutely no toxic and no obnoxious: the Adaspor ERS. The system doesn t need any particular attention and there is no risk for the medical staff about the chemical agents. The ERS System is compatible with high sensibility and high making criterion of endoscopes. There are many different safety devices to insure that every thing in the machine is constantly monitored. Even the environment protection has been studied a lot: the chemical agents needed are absolutely no dangerous and no polluting. 6 Ers

7 ERS Endoscope Reprocessing and Storage System Management System The ERS System is entirely checked by a PLC. The PLC has also an auto check-up device to make sure the cycle data bank. This permits a very high quality control and the evaluation error has reduced. An integrated printer makes a cycle data report, easy to read. The touch-screen monitor, programmed with different languages, it guides the operator to the correct use of the system. The system can be also connected to the supervision network (Endo-Itineris) for the online check-up and the remote maintenance. Maintenance The ERS machine is freestanding with upon part for store case and lower part for chemical storage. Both ERS/ESS are designed to enable easy access for maintenance with door lock and clearly light and labeled parts. Preventive maintenance program and troubleshooting are easy with clear instructions follow up using the touch screen. Water and air filters are easily replaceable using limited efforts. Filters lifetime is controlled by executed cycle and monitor the change time touch screen. Energy Saving And Economy Using The ERS System has been projected with particular attention to energy consumption and for a low management cost. Technical solution had also agree to CISA to reduces the water consumption, necessary for the reprocessing cycle. Area Design - Pass Through Pass through facilities are possibly designed to separate reprocessing area from storage area with airlock control. Industrialization Cisa s prominent position on the market has allowed the company to develop sufficient sales volumes to ensure, for each model of the range, a production in series. The repetition of all assembly operations and the industrialization of the manufacturing process can therefore provide a very favourable quality/cost ratio. Quality And Safety Certificates The ERS System is conform to the requirements of the Europeans standards ISO EN and to the standards CEI EN , CEI EN , CEI EN and to the standard UNI EN ISO The machines are CE marked according to the European Council Directive 93/42/EEC concerning medical devices. The equipment is conform to the normative ISO to the generic requirements for the characterization of the sterilizing agent as well as in compliance with the HTM 2030 generic requirements. Ers 7

8 ERS Connecting Guide Connection Guide The range of CISA connectors are made in way to cover the whole range of endoscopes from the main worldwide manufacturer. The ERS machine and, in the specific, the STORE-CASE of the ERS system has a modelled shape in order to accept any kind of flexible endoscope, even the one of new generation. The STORE-CASE has 7 connection inside that can be applied for the flushing of the endoscope. These connection are provided each of a silicon tube to which will be connected the actual endoscope flushing connector. The channels are named from 1 to 7 starting from the right to the left while looking inside an open STORECASE: CHANNEL 1: Preferentially reserved for flushing ELEVATOR channel of the endoscope. Otherwise dedicated to normal flushing. CHANNEL 2: Dedicated to leak test. CHANNEL 3-7: General flushing channel. Example As the store-case is compatible with the connectors made from most of endoscope manufacturers, it is not necessary to consider the CISA connectors as the unique solution for a washing configuration. As example, we will take now in consideration an Endoscope from a renowned manufacturer: A : Cylinder plug. B : Biopsy valve. C : Connector plug. D : Air pipe. E : Suction channel. Biopsy Valve Cap (B) The Channel Plug (connections A & B) and Injection Tube (connections C, D & E) flush the standard air, water and suction channels only. They do not flush any special channels (e.g, auxiliary-water, elevator-wire). Cylinder Plug (A) Connector Plug (C) Air Pipe Port (D) These are all channels which can be potentially used for the inner flushing of the endoscope, we will take in consideration one of the many configuration of washing available with this configuration. 8 Ers

9 ERS Connecting Guide Here the connection available for this kind of endoscope: Leak Test Auxiliary Elevator Suction Injection (1) Bypass (1) Bypass (2) Injection (2) Sanization All types and brands of endoscope connection adaptors are available with CISA storecase These connection are enough to flush all the inner channels of this kind of endoscope. In the case of the endoscope described in the figure above, is necessary to act in the following way: PLEASE NOTE: the following recommendation are for CISA connectors. It is obvious that is possible to use the plugs of the endoscope manufacturer simply adapting them to the silicone tube. A: Cylinder plug. The metal plug (commonly called rail you can see it represented in the figure) from the manufacturer cannot be used to connect CISA connectors. Remove the two push-buttons and insert them in the STORE-CASE for the washing, using the basket for accessories. The two CISA connector used in this place are the and the These connection must be applied to any of the tubes 3, 4, 5, 6 and 7 of the STORE-CASE. B: Biopsy Valve. The connection from CISA is present but we recommend to use the one from the manufacturer which is always present on the endoscope. The plug is usually a flow-reducer silicone rubber cap and no tubes are necessary to be connected here from the STORE-CASE. C: Connector plug. This is normal connection: it is usually left free as an outlet, otherwise it is possible to bypass the flow using the connection or , depending on the model of the endoscope. D: Air pipe. Usually left free as an outlet. E: Suction Channel. This channel is usually left as an outlet and does not need any connection. As is possible to see there is an internal connection between A and E: in case both channels are connected to a pressure source (the connection of the STORE-CASE) this is creating turbulence and high pressure inside the internal link between A and E. Both of them can be connected in case the endoscope has two Biopsy channels, which can afford the exhaust of the pressure coming from the flushing pumps. So actually, just connecting the two plugs in A, the endoscope is completely flushed internally. The other connections can be used in case of necessity and if the skill of the users is enough advanced in order to find different configuration of safe flushing. Ers 9

10 ERS Connecting Guide Looking at the connector that are not shown on the diagram but they are necessary for the work. LEAK TEST: this plug ( ) must be connected every time to the endoscope before the start of a cycle. Pay attention in keeping this connection dry and to not create humidity or water to get inside of it. For this reason during the LINE SANIZATION cycle using a normal STORE-CASE is necessary to place the plug along with the leak test connection ( ). ELEVATOR CHANNEL: See picture below. Inlet Inlet Elevator-Wire Channel Elevator All duodenoscopes (plus some therapeutic gastroscopes) have an elevator-wire channel inlet above the suction valve. The elevator channel is present in some endoscopes. When present is good practice to reserve always the connection number 1 of the STORE-CASE for this application. The elevator channel has a particular mechanism able to move a driver on the head of the endoscope in an angle of 90 for diagnostic purposes: this is done by a metal tractor wire inside the channels itself. Therefore the space for the flushing is reduced if compared to the other general channels: an option in the ERS touchscreen is able to control the flushing pressure inside this channel in order to not occur in alarms of maximum pressure due to the efforts that the pump is doing to flush this semi-obstructed channel. The elevator channel can be connected to the STORE-CASE with the connector AUXILIARY: See pictures below. In this two cases, when an AUXILIARY channel is present, is necessary to flush it independently because usually is not sharing any connection with the other general channels. Also in this case, the connection that could be used is the Auxiliary- Water Inlet Auxiliary-Water Inlet Cap Auxiliary-Water Channel Nozzle Auxiliary- Water Inlet Auxiliary-Water Channel Nozzle Some endoscopes have an auxiliary-water inlet light guide connector. Auxiliary- Water Inlet Some endoscopes have an auxiliary-water inlet above the suction valve. PLEASE NOTE: Obviously if an endoscope has both ELEVATOR and AUXILIARY channels is necessary to have two of these connection available. 10 Ers

11 ERS Endoscope Reprocessing and Storage System ERS1 - ERS2 STERILIZERS Dimensions mm ( W x H x D ) 1100 x 1700 x 750 Weight Kg 200 Power supply Volts 230 single phase, 50/60 Hz Electrical power Watts 1000 Cold water supply DN 20 Water pressure Bar 1-3 Compressed air Nl 15 Compressed air pressure Bar 6-8 Drain DN 32 Sound Level db. <53 * ERS 1 = 1 storecase ERS = 2 storecases ESS STORER Dimensions mm ( W x H x D ) 1100 x 1700 x 750 Weight Kg 200 Power supply Volts 230 single phase, 50/60 Hz Electrical power Watts 1000 Compressed air pressure Bar 6-8 Sound Level db. <53 STORE CASE Dimensions mm ( W x H x D ) 600 x 110 x 450 Weight Kg 4 Inside capacity litres 14,5 Endoscope transport trolley Ers 11

12 ERS catalogue - GB - 04 CISA reserves the right of modifications without prior notice. The reproduction of this document is allowed if explicitly authorised by Cisa S.p.A. only.

CISA Reprocessing Systems

CISA Reprocessing Systems CISA Reprocessing Systems ERS Endoscope Reprocessing and Storage System Feel the innovation 0123 ERS/ESS An innovative approach to the treatment, reprocessing, and aseptic storage of endoscopes and other

More information

ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing.

ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing. 11157 ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing. ETD DOUBLE: INTRODUCING THE FIRST OLYMPUS PASS- THROUGH WASHER-DISINFECTOR With the ETD Double, Olympus Has Advanced Its

More information

SERIE ENT. the fastest reprocessor designed for small endoscopes

SERIE ENT. the fastest reprocessor designed for small endoscopes SERIE ENT the fastest reprocessor designed for small endoscopes SERIE ENT a Smart process A complete cycle 1 in 14 minutes Improve your performance THE BEST TIME-EFFECTIVENESS RATIO ON THE MARKET The Serie

More information

WASSENBURG WD440 PT. Pass through endoscope washer-disinfector Optimum safety in workflow

WASSENBURG WD440 PT. Pass through endoscope washer-disinfector Optimum safety in workflow SPECIALISTS SPECIALISTS IN IN ENDOSCOPE ENDOSCOPE REPROCESSING REPROCESSING FOR FOR MORE MORE THAN THAN 30 30 YEARS! YEARS! WASSENBURG WD440 PT Pass through endoscope washer-disinfector Optimum safety

More information

WASSENBURG WD440. Toploader endoscope washer-disinfector Optimum process assurance

WASSENBURG WD440. Toploader endoscope washer-disinfector Optimum process assurance SPECIALISTS SPECIALISTS IN IN ENDOSCOPE ENDOSCOPE REPROCESSING REPROCESSING FOR FOR MORE MORE THAN THAN 30 30 YEARS! YEARS! WASSENBURG WD440 Toploader endoscope washer-disinfector Optimum process assurance

More information

SERIE 4. rapid, reliable, efficient

SERIE 4. rapid, reliable, efficient SERIE 4 rapid, reliable, efficient SERIE 4 Intuitive an machine 12/07/2014 15:23:00 1 35 C The power at your fingertips A NEW GENERATION OF INTERFACE The Serie 4 PA brings the benefit of a new intuitive

More information

WASSENBURG WD440. Toploader endoscope washer-disinfector Optimum process assurance

WASSENBURG WD440. Toploader endoscope washer-disinfector Optimum process assurance SPECIALISTS SPECIALISTS IN IN ENDOSCOPE ENDOSCOPE REPROCESSING REPROCESSING FOR FOR MORE MORE THAN THAN 30 30 YEARS! YEARS! WASSENBURG WD440 Toploader endoscope washer-disinfector Optimum process assurance

More information

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE What is an Automated Endoscope Reprocessor? An Automated Endoscopes Reprocessor (AER) performs all the cycle steps (fresh water preflush, rinsing, disinfection,

More information

SERIE 3. Everything has changed... but the best

SERIE 3. Everything has changed... but the best SERIE 3 Everything has changed... but the best SERIE 3 a Rapid system A complete cycle 1 in 20 minutes Brand new design A NEW GENERATION OF INTERFACE The new Serie 3 offers an innovative and intuitive

More information

GETINGE ISOFLEX MULTI-PURPOSE ISOLATOR

GETINGE ISOFLEX MULTI-PURPOSE ISOLATOR GETINGE ISOFLEX MULTI-PURPOSE ISOLATOR 2 GETINGE ISOFLEX THE ANSWER TO YOUR DAILY NEEDS FOR STERILE HANDLING In any sterile operation, maintaining the sterility of goods -- whether you have purchased them

More information

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System Advanced pass-through design Fast and efficient turnover Hands-free operation Built on proven ADVANTAGE PLUS technology FAST AND FLEXIBLE THE FUTURE

More information

ENDOSCOPE DECONTAMINATION- EDUCATION AND TRAINING COMPETENCY FRAMEWORK

ENDOSCOPE DECONTAMINATION- EDUCATION AND TRAINING COMPETENCY FRAMEWORK ENDOSCOPE DECONTAMINATION- EDUCATION AND TRAINING COMPETENCY FRAMEWORK Standardising the manual cleaning and decontamination process of flexible endoscopes throughout Lothian. C:\Users\Scott\Documents\Endoscopy\website

More information

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System Advanced pass-through design Fast and efficient turnover Hands-free operation Built on proven ADVANTAGE PLUS technology FAST AND FLEXIBLE THE FUTURE

More information

ADVANTAGE PLUS Pass-Thru

ADVANTAGE PLUS Pass-Thru ADVANTAGE PLUS Pass-Thru AUTOMATED ENDOSCOPE REPROCESSOR REPROCESSING Reprocessing Reimagined Cantel is your partner in the fight against healthcareassociated infections. Healthcare-associated infections

More information

SERIE TEE. automatic reprocessor for TEE probes

SERIE TEE. automatic reprocessor for TEE probes SERIE TEE automatic reprocessor for TEE probes SERIE TEE Smart a technology A complete cycle 1 in 14 minutes CE MARK compliant Improve your performance with our TEE device DESIGNED FOR TEE PROBES The Serie

More information

SERIE 4. rapid, reliable, efficient

SERIE 4. rapid, reliable, efficient SERIE 4 rapid, reliable, efficient SERIE 4 Intuitive an machine The power at your fingertips A NEW GENERATION OF INTERFACE HMI with touch screen display enables easy and fast access to all cycle and machine

More information

GETINGE 8666/8668 WASHER-DISINFECTOR. Always with you

GETINGE 8666/8668 WASHER-DISINFECTOR. Always with you GETINGE 8666/8668 WASHER-DISINFECTOR Always with you 2 8666/8668 LEAN BACK AND LET THE GETINGE 8666/8668 DEAL WITH EVERYTHING The Getinge 8666/8668 is the optimal system for advanced cleaning and disinfection

More information

Innova. New E2/E3 Series. Safe Reprocessing of Flexible and Rigid Endoscopes

Innova. New E2/E3 Series. Safe Reprocessing of Flexible and Rigid Endoscopes Safe Reprocessing of Flexible and Rigid Endoscopes Perfect Match of Reprocessing Parameters at Maximum Flexibility R e p r o c e s s i n g P r o c e s s a n d Te c h n o l o g y Well Equipped for the Future:

More information

Getinge HS55 Hospital sterilizer

Getinge HS55 Hospital sterilizer Getinge HS55 Hospital sterilizer The most versatile, reliable and Easy-to-use hospital sterilizer in the world The Getinge HS55 is a fully automatic steam sterilizer. It has pre-set programs for the most

More information

Centralisation of Endoscope Decontamination. Aisling Bonner Manager HSDU Altnagelvin Hospital

Centralisation of Endoscope Decontamination. Aisling Bonner Manager HSDU Altnagelvin Hospital Centralisation of Endoscope Decontamination Aisling Bonner Manager HSDU Altnagelvin Hospital Endoscope Decontamination WHY? To prevent infection from patient to patient. To make equipment safer to handle.

More information

GETINGE HS55 HOSPITAL STERILIZER. Always with you

GETINGE HS55 HOSPITAL STERILIZER. Always with you GETINGE HS55 HOSPITAL STERILIZER Always with you 2 Getinge HS55 GETINGE HS55 The most versatile, reliable and EAsy-to-use hospital sterilizer in the world The Getinge HS55 is a fully automatic steam sterilizer.

More information

DSC8000. store, dry & protect your endoscope for patient safety

DSC8000. store, dry & protect your endoscope for patient safety DSC8000 store, dry & protect your endoscope for patient safety DSC8000 a high level Safety The unique system of protection and safety for your endoscope AN INDIVIDUAL SHOCK PROTECTIVE TRAY Each endoscope

More information

Best Practices for Reprocessing Endoscopes

Best Practices for Reprocessing Endoscopes Best Practices for Reprocessing Endoscopes Reprocessing of Endoscopes Reprocessing Room Standards The resources referenced include: Canadian Standards Association Provincial Infectious Disease Advisory

More information

ENDOSCOPY PRACTICE Manual cleaning and Disinfection of flexible endoscopes

ENDOSCOPY PRACTICE Manual cleaning and Disinfection of flexible endoscopes 1.0 Purpose Every patient undergoing endoscopy should be examined with clean, disinfected equipment. All endoscopic equipment will be cleaned and disinfected / sterilized according to current recommended

More information

The purpose of this DOPs form is to provide a universal training and assessment tool for continuity when training in manual cleaning processes.

The purpose of this DOPs form is to provide a universal training and assessment tool for continuity when training in manual cleaning processes. 1 Formative DOPS Assessment Form Manual Cleaning of Gastrointestinal Endoscopes Hospital: Trainee s name (print): Job title: Date of assessment: Review date: Manufacturer: Equipment Models: (list endoscopes

More information

Response Schedule 2 Decontamination: Multichamber Washer Disinfector of 12.

Response Schedule 2 Decontamination: Multichamber Washer Disinfector of 12. Innova Multi-Chamber Tunnel Washer-Disinfectors For Hospitals, Service Centres And Industry T5 /ISO High Performance For The Central Supply A r e a s o f O p e r a t i o n BHT the Experts for Innovative

More information

LAB DIVISION. STERILIZATION cglp Process Equipment for Research and Microbiological Laboratories

LAB DIVISION. STERILIZATION cglp Process Equipment for Research and Microbiological Laboratories LAB DIVISION STERILIZATION cglp Process Equipment for Research and Microbiological Laboratories LAB division Company LAST Technology is the worldwide provider for cleaning, decontamination, disinfection

More information

Steam Sterilizer. SA Series. for hospitals, CSSD and medical centers

Steam Sterilizer. SA Series. for hospitals, CSSD and medical centers Steam Sterilizer SA Series for hospitals, CSSD and medical centers Driven by customer needs Colussi is a leading infection control solution provider, supplying the healthcare, laboratory research and pharma

More information

Manner of Assessment Code (check all that apply) & Surveyor Notes. Yes N/A. Yes. Yes N/A N/A. Yes N/A. N/A Yes N/A

Manner of Assessment Code (check all that apply) & Surveyor Notes. Yes N/A. Yes. Yes N/A N/A. Yes N/A. N/A Yes N/A Section 4. L Reprocessing of Semi-Critical Equipment Elements to be assessed Manner of Assessment Code (check all that apply) & Surveyor Notes Manner of Assessment Code (check all that apply) & Surveyor

More information

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes Webinar FAQ

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes Webinar FAQ Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes Webinar FAQ Disclaimer: The Society of Gastroenterology Nurses and Associates, Inc. assume no responsibility for the

More information

CUSTOMER: REFERENCE: DPTE TRANSFER SYSTEM Autoclavable containers PRODUCT SPECIFICATION PRODUCT The DPTE transfer system is recognized as being the safest method for introducing and removing sterile and/or

More information

Medical waste treatment

Medical waste treatment Medical waste treatment Pass-through execution system for biohazard waste treatment WaSter 50 WaSter : Compact, Safe, Fast for Biohazard waste treatment. The biological risk coming from the management

More information

Recommended Procedure for Sampling Gastrointestinal Flexible Endoscopes

Recommended Procedure for Sampling Gastrointestinal Flexible Endoscopes SAMPLING GUIDE* Recommended Procedure for Sampling Gastrointestinal Flexible Endoscopes This document provides the recommended procedure for obtaining acceptable samples from a flexible endoscope without

More information

ETD4. More than meets the eye.

ETD4. More than meets the eye. ETD4 More than meets the eye. More than meets the eye ETD4 intelligent reliable safe Setting endoscope reprocessing standards With ETD4, Olympus has made significant progress in providing you with even

More information

GETINGE FD1600 FRONT LOADED FLUSHER-DISINFECTOR. Always with you

GETINGE FD1600 FRONT LOADED FLUSHER-DISINFECTOR. Always with you GETINGE FD1600 FRONT LOADED FLUSHER-DISINFECTOR Always with you 2 Getinge FD1600 Getinge FD1600 3 COMBATING CROSS-INFECTION SIMPLY & EFFECTIVELY With its attractive modern design, easy operation and excellent

More information

Testing the Endoscope Journey vs the Decontamination Process. Wayne Spencer

Testing the Endoscope Journey vs the Decontamination Process. Wayne Spencer Testing the Endoscope Journey vs the Decontamination Process Wayne Spencer Historically Validation has focused on the process with only sporadic testing of the device used on the patient Probably with

More information

Uniclean PL II 10 Premium Line

Uniclean PL II 10 Premium Line Uniclean PL II 10 Premium Line Washer-Disinfector for 10 DIN trays High performance on a small footprint MMM. Protecting human health. Top quality and reliabily MMM products are distinguished by their

More information

Getinge K-Series. Tabletop Sterilizers. This document is intended to provide information to an international audience outside of the US.

Getinge K-Series. Tabletop Sterilizers. This document is intended to provide information to an international audience outside of the US. Getinge K-Series Tabletop Sterilizers This document is intended to provide information to an international audience outside of the US. High-speed sterilization Superior capacity and efficiency Getinge

More information

EUROSTEAM. Steam sterilizer for laboratory. series HSD

EUROSTEAM. Steam sterilizer for laboratory. series HSD EUROSTEAM Steam sterilizer for laboratory series 6-8-12-18 HSD EUROPEAN INFECTION CONTROL Series: lab 6,8,12 and 18 with Serie 6.500 HSD Serie 6.700 HSD Serie 6.900 HSD Serie 8.600 HSD Serie 8.900 HSD

More information

WASSENBURG DRY320. Drying and storage cabinet A revolution in ergonomics

WASSENBURG DRY320. Drying and storage cabinet A revolution in ergonomics SPECIALISTS SPECIALISTS IN IN ENDOSCOPE ENDOSCOPE REPROCESSING REPROCESSING FOR FOR MORE MORE THAN THAN 30 30 YEARS! YEARS! WASSENBURG DRY320 Drying and storage cabinet A revolution in ergonomics DRY320

More information

Automatic Isokinetic Sampler ST5

Automatic Isokinetic Sampler ST5 Automatic Isokinetic Sampler ST5 Automatic Isokinetic Sampler ST5 Description The ST5 is the next generation isokinetic sampler, developed to be efficient, rugged, accurate and user friendly. The perfect

More information

Anyvib Vibration Test Chambers

Anyvib Vibration Test Chambers Anyvib Vibration Test Chambers WHY ANYVIB? Because anyvib is the easiest way to combine any kind of shaker with an environmental test chamber. anyvib is a new family of climatic chambers that can be interfaced

More information

Medical waste treatment

Medical waste treatment Medical waste treatment EUROPEAN INFECTION CONTROL Pass-through execution system WaSter 50 for biohazard waste treatment WaSter 100 2 WaSter: Compact, Safe, Fast for the Treatment of Biohazard waste. The

More information

series HSD Steam sterilizer EUROSTEAM Medical device

series HSD Steam sterilizer EUROSTEAM Medical device EUROSTEAM Steam sterilizer series 1-2-4 HSD Medical device EUROPEAN INFECTION CONTROL Series: 1, 2 and 4 with Series 1.80 HSD Series 1.100 HSD Series 2.150 HSD Series 2.200 HSD Series 2.250 HSD Ergonomic

More information

Getinge Automation System for washer-disinfectors

Getinge Automation System for washer-disinfectors Getinge Automation System for washer-disinfectors A part of our user-centric range Designed for the user when time is critical To secure best routines for high efficiency in processing in smaller to larger

More information

PROVEN IN THE FIGHT AGAINST

PROVEN IN THE FIGHT AGAINST GETINGE FD1800-series FLUSHER-DISINFECTORs 2 Getinge FD1800 Getinge FD1800 3 PROVEN IN THE FIGHT AGAINST CROSS-INFECTION The excellent cleaning and disinfection performance of Getinge FD1800-series has

More information

GETINGE HS44 STERILIZERS FOR HIGH CAPACITY AT POINT OF USE. Always with you

GETINGE HS44 STERILIZERS FOR HIGH CAPACITY AT POINT OF USE. Always with you GETINGE HS44 STERILIZERS FOR HIGH CAPACITY AT POINT OF USE Always with you 2 Getinge HS44 lights on for the new generation sterilizers The new Getinge HS44 is one of the new breed of state-of-the art sterilizers

More information

REVERSE OSMOSIS SYSTEM USER'S MANUAL. Excellent Product, Excellent Water! My PurePro X6

REVERSE OSMOSIS SYSTEM USER'S MANUAL. Excellent Product, Excellent Water! My PurePro X6 REVERSE OSMOSIS SYSTEM USER'S MANUAL UV Plus! Excellent Product, Excellent Water! My PurePro X6 PUREPRO X6 Thank you very much for selecting Pure-Pro Water Corp. In order to bring the best use of your

More information

HRO-50 Water Purifier

HRO-50 Water Purifier HRO-50 Water Purifier Product Installation & Operation Manual Honeywell Environmental & Combustion Controls (Tianjin) Co., Ltd. Content Important Notes P2 Product Functions P3-P5 Installation Instructions

More information

RD01 WHAT S IN THE BOX INSTALLATION MANUAL

RD01 WHAT S IN THE BOX INSTALLATION MANUAL INSTALLATION MANUAL RD0 WHAT S IN THE BOX Rain Director control panel with mode indicators, programming buttons and control valves and 0 V AC to V wall adapter. Control panel measures 80mm W x 70mm H x

More information

Getinge HS44 sterilizer for high capacity at point of use

Getinge HS44 sterilizer for high capacity at point of use Getinge HS44 sterilizer for high capacity at point of use Lights on for the new generation sterilizers The new Getinge HS44 is one of the new breed of state-ofthe art sterilizers from the world s leading

More information

Endoscopy Reprocessing Trends. Wayne Spencer United Kingdom

Endoscopy Reprocessing Trends. Wayne Spencer United Kingdom Endoscopy Reprocessing Trends Wayne Spencer United Kingdom The Poor Relation? The Concept Of A level Playing Field? Irrespective of where the decontamination is performed or who it is performed by the

More information

TOTAL SOLUTION FOR ENDOSCOPE REPROCESSING

TOTAL SOLUTION FOR ENDOSCOPE REPROCESSING TOTAL SOLUTION FOR ENDOSCOPE REPROCESSING A NEED FOR A COMPLETE PROCESS Lionel PINEAU PhD France PATHOGEN TRANSMISSION RELATED TO ENDOSCOPE WHAT IS THE CONTAMINATION RISK? Rates of bacteremia and infectious

More information

GS Hospital Autoclaves

GS Hospital Autoclaves GS Hospital Autoclaves For CSSDs, OR & Medical Centers 155 Liters & 245 Liters 1 StU & 2 StU GS Economic Line Hospital Autoclaves GS hospital autoclaves are designed for Hospital CSSD, OR, and Medical

More information

AUTOMATED ENDOSCOPE REPROCESSOR. OER-Pro Easy. Fast. Reliable.

AUTOMATED ENDOSCOPE REPROCESSOR. OER-Pro Easy. Fast. Reliable. AUTOMATED ENDOSCOPE REPROCESSOR OER-Pro Easy. Fast. Reliable. Olympus Endoscope Reprocessor The only reprocessor designed by an endoscope manufacturer. The OER-Pro provides high-level disinfection of Olympus

More information

CDWA3 / CDWA4 CDWAH. Page 4. BASKET ZONE: water pressure, spray system performance, detergent chemistry and concentration, temperature.

CDWA3 / CDWA4 CDWAH. Page 4. BASKET ZONE: water pressure, spray system performance, detergent chemistry and concentration, temperature. Rev. 2 March 2017 Control of cleaning and washing processes of medical instruments and materials is highly important since its outcome affects the success of subsequent disinfection and/or sterilization

More information

1.1 WORK INCLUDED A. Nortec MLRO Series reverse osmosis water treatment system as indicated on drawing[s] and as indicated on schedule[s].

1.1 WORK INCLUDED A. Nortec MLRO Series reverse osmosis water treatment system as indicated on drawing[s] and as indicated on schedule[s]. MLRO Specification PART 1 - GENERAL 1.1 WORK INCLUDED A. Nortec MLRO Series reverse osmosis water treatment system as indicated on drawing[s] and as indicated on schedule[s]. 1.2 QUALITY ASSURANCE A. Certifications,

More information

TRACECARE Monitoring, Reporting & Traceability Solutions

TRACECARE Monitoring, Reporting & Traceability Solutions TRACECARE Monitoring, Reporting & Traceability Solutions THE CISA GROUP COMPANY COMPANY PROFILE CISA has been manufacturing and selling sterilization systems for over 60 years for both hospitals and industrial

More information

RO102 P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address RO102

RO102 P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address RO102 Type of product RO102 Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM PURE- REVERSE OSMOSIS SYSTEM 15 RO102 USER'S MANUAL 01 Introduction of RO102 02 What is reverse osmosis 03 Components

More information

BEST PARTER & BEST SOLUTION RENO Plasma Sterilizer

BEST PARTER & BEST SOLUTION RENO Plasma Sterilizer Web: www.medcon.com.au Email: info@medcon.com.au MED-CON PTY LTD SOLUTIONS FOR BIO-SECURITY Phone: 03 9753 2710 Fax: 03 9753 2722 BEST PARTER & BEST SOLUTION RENO Series - Benefits Rapid Sterilization

More information

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM APPLICATION For rapid, safe, standardized low-temperature liquid chemical sterilization of heat-sensitive critical and semi-critical devices. DESCRIPTION

More information

biopsy valves & irrigation accessories

biopsy valves & irrigation accessories biopsy valves & irrigation accessories BioShield biopsy valves and irrigation accessories are single-use, offering unsurpassed protection for patients and staff. Why single-use valves? It is nearly impossible

More information

System Catalogue. Medical Waste and Linen Transfer System Living a Safe Future Living the Dream. System Catalogue

System Catalogue. Medical Waste and Linen Transfer System Living a Safe Future Living the Dream. System Catalogue Medical Waste and Linen Transfer System Living a Safe Future Living the Dream System Catalogue Page 1 of 20 Safe Transfer Summary 1. Concept 2. System components 3. Algorithm 4. Mechanical System Features

More information

Calciumreactor KR Blue. Operation Manual GB

Calciumreactor KR Blue. Operation Manual GB Calciumreactor KR Blue Operation Manual GB Filter for the adjustment of the natural equilibrium between calcium and carbonic acid in aquaria. For seawater aquaria from 200 up to 1,000 l. With the purchase

More information

Milli-Q Reference Water Purification System. The reference for ultrapure water systems

Milli-Q Reference Water Purification System. The reference for ultrapure water systems Milli-Q Reference Water Purification System The reference for ultrapure water systems Ultrapure water by Merck Millipore Easily prepare solutions with the low flow function to precisely adjust the meniscus

More information

THE GETINGE SEALER RANGE SETS A NEW STANDARD FOR QUALITY SEALERS

THE GETINGE SEALER RANGE SETS A NEW STANDARD FOR QUALITY SEALERS THE GETINGE SEALER RANGE SETS A NEW STANDARD FOR QUALITY SEALERS 2 Getinge Sealer Range A SEALER FOR EVERY NEED EFFECTIVE, RELIABLE AND USER FRIENDLY The entire circulation of sterile goods has to be considered

More information

YOUR SPLASH PAD RESOURCE

YOUR SPLASH PAD RESOURCE 1 Index Permits & Inspections Material List Warnings Splash Pad Types Pre-Site Grading Plumbing Schematic Pressure Testing Concrete Preparation and Pour Housing/Nozzle Installation Above Ground Water Feature

More information

Volume 13, Issue 5/ Medtech

Volume 13, Issue 5/ Medtech Volume 13, Issue 5/2011 - Medtech The New Central Sterile Supply Department of University Hospital Authority St. Orsola- Malpighi Polyclinic The new Central Sterile Supply Department (CSSD) of the University

More information

Steam Sterilizers. DLOV & DLOM series. more than sixty years of experience in sterilization. DE LAMA s Quality Management System is certified:

Steam Sterilizers. DLOV & DLOM series. more than sixty years of experience in sterilization. DE LAMA s Quality Management System is certified: Steam Sterilizers DLOV & DLOM series DE LAMA s Quality Management System is certified: more than sixty years of experience in sterilization UNI EN ISO 9001 - Cert. n 0351 UNI EN ISO 13485 - Cert. n 1275

More information

Validation Strategy for an Automated Endoscope Reprocessor

Validation Strategy for an Automated Endoscope Reprocessor Validation Strategy for an Automated Endoscope Reprocessor November 16, 2010 Bradley Catalone AER Validation Strategy System Approach page 1 AER Validation Strategy AER Scope-specific connectors Requires

More information

Ethicon, Inc All rights reserved. EVOTECH and the EVOTECH logo are registered trademarks owned by Advanced Sterilization Products.

Ethicon, Inc All rights reserved. EVOTECH and the EVOTECH logo are registered trademarks owned by Advanced Sterilization Products. Ethicon, Inc. 2009. All rights reserved. EVOTECH and the EVOTECH logo are registered trademarks owned by Advanced Sterilization Products. Consistent Cleaning with No Brushing. Now, the labor-intensive

More information

Responses to Questions for SYSTEM 1E Process Monitoring and Validation Webinar

Responses to Questions for SYSTEM 1E Process Monitoring and Validation Webinar Responses to Questions for SYSTEM 1E Process Monitoring and Validation Webinar MONITORING THE SYSTEM 1E PROCESSOR Q: I want to confirm that there is no need for a Biological Indicator (BI) and that use

More information

Instructions for Use: Duodenoscope Sampling Kit

Instructions for Use: Duodenoscope Sampling Kit Instructions for Use: Duodenoscope Sampling Kit Brand Name of Product Generic Name of Product Product Code Number(s) Intended Use Duodenoscope Sampling Kit Endoscope sampling and culturing kit CK-250,

More information

Donatello. Tissue processor Series 2

Donatello. Tissue processor Series 2 Tissue processor Series 2 Tissue Tissueprocessor processor Series Series 2 2 1 1 2 2 3 3 6 6 4 4 7 5 5 7 1 1 2 2 3 3 4 4 5 5 6 6 7 7 15 LCD Touch screen PC monitor paraffin reservoirs 15 3LCD Touch screen

More information

Endoscope Decontamination. A Tube in a Hole??

Endoscope Decontamination. A Tube in a Hole?? Endoscope Decontamination A Tube in a Hole?? John Prendergast AE(D) MIHEEM Senior Decontamination Engineer (Wales) May 2016 Note This presentation is my personal interpretation and not NHS Wales policy.

More information

Milli-Q Reference Water Purification System. The reference for ultrapure water systems

Milli-Q Reference Water Purification System. The reference for ultrapure water systems Milli-Q Reference Water Purification System The reference for ultrapure water systems Ultrapure water by Merck Millipore Easily prepare solutions with the low flow function to precisely adjust the meniscus

More information

John van Bergen Henegouw. Monitoring the Performance of your Automated Endoscope Reprocessor. Validation

John van Bergen Henegouw. Monitoring the Performance of your Automated Endoscope Reprocessor. Validation John van Bergen Henegouw Monitoring the Performance of your Automated Endoscope Reprocessor Validation Contents: Validation of AERs 1. History of validation in the Haga Hospital 2. Guidelines 3. Annual

More information

Data Logger Systems. Medical CSSD Pharmaceutical Food

Data Logger Systems. Medical CSSD Pharmaceutical Food Data Logger Systems for Thermal Process Validation Medical CSSD Pharmaceutical Food Flexible Data Logger Systems For Thermal Validations ebro offers flexible measurement and documentation systems for validating

More information

BIOTECH-GERMANDE ENDOSCOPE REPROCESSING WITH BRUSHLESS CLEANING PROCESS CONDITIONS. Lionel PINEAU PhD

BIOTECH-GERMANDE ENDOSCOPE REPROCESSING WITH BRUSHLESS CLEANING PROCESS CONDITIONS. Lionel PINEAU PhD ENDOSCOPE REPROCESSING WITH BRUSHLESS CLEANING PROCESS CONDITIONS Lionel PINEAU PhD CONTENT General considerations Endoscope reprocessing, channel brushing, cleaning claims Description of the 2013 study

More information

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes National Endoscopy Programme Decontamination Standards for Flexible Endoscopes Updated March 2008 Introduction Providing an effective endoscope decontamination service within a safe environment is an essential

More information

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING Flows to 200 GPM. TDH to 95 Feet at 1750 RPM Free Standing or Guide Rail Design. Available in Standard Submersible or Explosion Proof Design. Provided with 25 feet of submersible motor power cable. Cast

More information

STERIVAP HP. Large Steam Sterilizer for Health Care for Original Without Compromises. protecting human health

STERIVAP HP. Large Steam Sterilizer for Health Care for Original Without Compromises. protecting human health STERIVAP HP Large Steam Sterilizer for Health Care for Original Without Compromises protecting human health Tradition, Quality, Innovation Meeting the latest standards Offer of Services More Than You Can

More information

Depyrogenation Oven. depyrogenation and dry heat sterilization

Depyrogenation Oven. depyrogenation and dry heat sterilization Depyrogenation Oven depyrogenation and dry heat sterilization Lytzen philosophy The philosophy behind the Lytzen Depyrogenation ovens is never to compromize on our high level of quality in every detail.

More information

Oregon Health Services - Drinking Water Program

Oregon Health Services - Drinking Water Program Oregon Health Services - Drinking Water Program Drinking Water Hauling Guidelines June, 2008 INTRODUCTION Hauling water for drinking purposes is not regulated in the State of Oregon. The mission of the

More information

biopsy valves & irrigation accessories

biopsy valves & irrigation accessories biopsy valves & irrigation accessories BioShield biopsy valves and irrigation accessories are single-use, offering unsurpassed protection for patients and staff. Why single-use valves? It is nearly impossible

More information

REVERSE OSMOSIS WATER TREATMENT

REVERSE OSMOSIS WATER TREATMENT REVERSE OSMOSIS WATER TREATMENT LTF 2, LTF 3 and LTF 4 SERIES RO SYSTEMS 14,400 TO 252,000 GALLONS PER DAY AND LARGER Lakeside Water for Affordable Pure Water Technology 1 P age Packaged Reverse Osmosis

More information

i-leaktek 6600 Leak and Seal Strength Tester

i-leaktek 6600 Leak and Seal Strength Tester i-leaktek 6600 Leak and Seal Strength Tester Online Data Management system for Packaging Testing - The ultimate cloud computing technology for test data processing and management Designed with embedded

More information

Specialists in autoclave, sterilizer and decontamination equipment

Specialists in autoclave, sterilizer and decontamination equipment E S T S European Sterilizer & Technical Services Specialists in autoclave, sterilizer and decontamination equipment Portfolio Our portfolio of clients comes from the following industry sectors: Hospitals

More information

CMS, FDA and AAMI Requirements for Bicarbonate Systems Made Simple. Compiled January 2012 by AmeriWater Incorporated

CMS, FDA and AAMI Requirements for Bicarbonate Systems Made Simple. Compiled January 2012 by AmeriWater Incorporated CMS, FDA and AAMI Requirements for Bicarbonate Systems Made Simple Compiled January 2012 by AmeriWater Incorporated Background on the Standards FDA, 21 CFR Sec. 876.5820(a) states that hemodialysis systems

More information

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy!

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy! Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy! Dr. Michelle J. Alfa, Ph.D., FCCM Medical Director, Clinical Microbiology, Diagnostic Services of Manitoba, Winnipeg, Canada Disclaimers:

More information

Bulk Steam Autoclaves. Laboratory & Scientific Line

Bulk Steam Autoclaves. Laboratory & Scientific Line Bulk Steam Autoclaves Laboratory & Scientific Line Bulk Steam Autoclaves for Life Sciences The bulk autoclave line is designed for the sterilization of laboratory products and instruments including cages,

More information

illatu/fill/seal Packaging System

illatu/fill/seal Packaging System mutumaum Laquiu roackagmm, Packaging Processing illatu/fill/seal Packaging System With the ALP System you're not limited to one particular container design If you're still buying empty plastic containers

More information

RD01 WHAT S IN THE BOX INSTALLATION MANUAL

RD01 WHAT S IN THE BOX INSTALLATION MANUAL INSTALLATION MANUAL RD0 WHAT S IN THE BOX Rain Director control panel with mode indicators, programming buttons and control valves and 0 V AC to V wall adapter. Control panel measures 80mm W x 70mm H x

More information

Installation Instructions, Pressure Regulator Series Manual Model: 20313, Air motor Operated: F20313, Hydraulic Motor Operated: G20313

Installation Instructions, Pressure Regulator Series Manual Model: 20313, Air motor Operated: F20313, Hydraulic Motor Operated: G20313 Installation Instructions, Pressure Regulator 20313 Series Manual Model: 20313, Air motor Operated: F20313, Hydraulic Motor Operated: G20313 1. GENERAL ------------------------------------------------------------------------------

More information

Guidelines for sampling and maintenance of the QualiTru Side Mount Truck Sampler

Guidelines for sampling and maintenance of the QualiTru Side Mount Truck Sampler Guidelines for sampling and maintenance of the QualiTru Side Mount Truck Sampler QUALITRU HAULER TRUCK MOUNT SIDE SAMPLER 1. Purpose In an effort to increase the security, health and safety to haulers

More information

Fast. Easy to use. Secure traceability.

Fast. Easy to use. Secure traceability. Sterilization, Hygiene and Maintenance Fast. Easy to use. Secure traceability. NEW Lisa Sterilizer PERFORMANCE* Accelerated type B cycle thanks to Eco Dry technology EASY TO USE thanks to a new user interface

More information

Air Compressor Series.

Air Compressor Series. Air Compressor Series Leading the Industry FS-Elliott is best positioned to provide you with the highest quality air compressors, parts, and services to ensure optimal performance and reliability of your

More information

Equipment Design Consideration for Cleaning & Cleaning Validation

Equipment Design Consideration for Cleaning & Cleaning Validation Equipment Design Consideration for Cleaning & Cleaning Validation Gamal Amer, Ph. D. Principal Premier Compliance Services, Inc. All rights reserved. Do not copy without permission. 1 Cleaning and Cleaning

More information

Partnership. Large Steam Autoclaves for the Life Sciences. Laboratory Line

Partnership. Large Steam Autoclaves for the Life Sciences. Laboratory Line Partnership Large Steam Autoclaves for the Life Sciences Laboratory Line Large Steam Autoclaves for the Life Sciences Sterilization in a laboratory environment has its unique requirements. Tuttnauer laboratory

More information