IV Catheter-Drawn Blood Cultures: Discarding the Initial Aliquot of Blood Does Not Reduce. Contamination Rates

Size: px
Start display at page:

Download "IV Catheter-Drawn Blood Cultures: Discarding the Initial Aliquot of Blood Does Not Reduce. Contamination Rates"

Transcription

1 JCM Accepts, published online ahead of print on July 00 J. Clin. Microbiol. doi:0./jcm.00-0 Copyright 00, American Society for Microbiology and/or the Listed Authors/Institutions. All Rights Reserved. 0 IV Catheter-Drawn Blood Cultures: Discarding the Initial Aliquot of Blood Does Not Reduce Contamination Rates Sukrut Dwivedi, Rohit Bhalla, Donald R. Hoover,, Melvin P. Weinstein, Division of Infectious Diseases, Allergy & Immunology, Departments of Medicine and Pathology, UMDNJ-Robert Wood Johnson Medical School, New Brunswick, NJ, and Department of Statistics and Biostatistics, Rutgers University, New Brunswick, NJ Running Head: IV Catheter-Drawn Blood Cultures Corresponding Author: Melvin P. Weinstein Division of Infectious Diseases, Allergy & Immunology Robert Wood Johnson Medical School New Brunswick, NJ Ph: -- weinstei@umdnj.edu Downloaded from on September, 0 by guest

2 0 Abstract Although venipuncture is the preferred method for obtaining blood cultures, specimens often are obtained from intravenous catheters (IVC). For IVC-drawn blood cultures, some authorities recommend discarding the initial -0 ml of blood to reduce contamination and remove potential inhibitory substances. To determine whether this practice reduced contamination rates (CR), we assessed the results of IVC-drawn blood cultures in adults. Thirty ml of blood was obtained aseptically. The first 0 ml, rather than being discarded, was inoculated to an aerobic culture vial. Using a second sterile syringe, 0 ml of blood was obtained and inoculated in 0 ml aliquots to aerobic and anaerobic culture vials. Positive cultures were evaluated to assess clinical significance (true vs. contaminant). From IVC-drawn blood culture pairs, both vials were contaminated in (.%); only the discard vial was contaminated in (.%); and only the standard vial was contaminated in (.%). Overall CR were 0.% for the discard vial versus 0.% for the standard vial (P=0.0). We conclude that discarding an initial aliquot of blood when obtaining blood cultures from IVCs does not reduce CR. Downloaded from on September, 0 by guest

3 0 0 Background The standard method for obtaining blood for culture is venipuncture using aseptic technique. With greater utilization of intravenous access catheters (e.g., PICC, Hickman, etc.), blood cultures often are obtained from these devices. Yet there is no standardized method for obtaining blood for culture by this technique. Several reports have demonstrated increased blood culture contamination rates (i.e. false positive results) when blood cultures are obtained from catheters (,,0,) which, in turn, can lead to inappropriate antibiotic administration as well as additional unnecessary diagnostic testing. Some authorities recommend discarding the first -0 ml of blood when obtaining blood from intravenous catheters (IVCs) prior to inoculating the blood culture vials (), whereas others do not (,,). The purpose of discarding these aliquots of blood is to remove any substances that could potentially inhibit microbial growth (e.g., heparin) (,) and to reduce blood culture contamination rates. However, there are few published systematic assessments of this issue, no consensus recommendations on how to draw blood cultures from an IVC, and no controlled comparative evaluations of different techniques to obtaining blood culture samples from an IVC. It has been standard practice at our institution to discard the first 0 ml of blood prior to obtaining blood for culture from IVCs. If patients have repeated blood cultures, in which 0 ml of blood is discarded with each culture, nosocomial anemia may occur or worsen and result in added morbidity (,,, ). To Downloaded from on September, 0 by guest

4 0 0 determine whether discarding the initial aliquot of blood from IVC-drawn blood cultures reduces contamination, we inoculated the initial 0 ml sample of blood that would have been discarded to an aerobic blood culture vial and compared contamination rates in these vials with contamination rates in the standard blood sample obtained for culture from the same patient. MATERIALS AND METHODS Adult inpatients ( years old) on three oncology nursing units for whom the attending physician ordered a catheter drawn blood culture from March to October, 00, at Robert Wood Johnson University Hospital, New Brunswick, NJ, were included. The study was approved by the Robert Wood Johnson Medical School Institutional Review Board. For this study, a "set" was defined as three culture bottles, aerobic and anaerobic, obtained from an indwelling catheter. The catheter hub was initially cleansed with 0% isopropyl alcohol, then allowed to dry. The hub was then disinfected with % iodine tincture and allowed to dry for 0 seconds. Using a sterile syringe, the IVC was flushed with 0 ml of normal saline solution. Using a sterile syringe, 0 ml of blood, the discard aliquot, was drawn from the IVC and inoculated to a Bactec Plus Aerobic/F culture vial. The IVC hub was then recleansed with isopropyl alcohol and iodine tincture in the same fashion. Using a Downloaded from on September, 0 by guest

5 sterile syringe, 0 ml of blood was obtained and inoculated in 0 ml aliquots to a Bactec Plus Aerobic/F vial, the standard vial, and a Bactec Plus Anaerobic/F vial. 0 0 Positive blood culture sets were analyzed to determine whether the isolates represented true infection or contamination, and contamination rates were compared in the discard versus the standard aerobic vial. Factors used to differentiate contaminants from clinically important pathogens included the identity of organism, number of positive blood culture sets versus the number of culture sets obtained and, when appropriate, review of the medical record of the patient with the positive culture to compare the results to those of any peripheral blood cultures obtained during the same time frame (0). Data were entered and saved on Excel spreadsheets. Overall proportions of contamination in the discard and standard vials were then compared using McNemar's Discordant Pairs Test of matched results for the same subject. RESULTS During the study period, there were a total of blood culture sets collected from IVCs with matched discard and standard vial pairs (Table). In instances (.%) only the discard vial was contaminated, and in instances (.%) only the standard vial was contaminated. In instances both the standard and discard vials were contaminated (.%). Thus, overall contamination rates for Downloaded from on September, 0 by guest

6 0 0 the discard and standard vials were 0.% and 0.%, respectively (P=.0; % CI for difference in CRs from the normal approximation fo the multinomial, -.% to +.%). In instances only the discard bottle grew a true pathogen, and in instances only the standard bottle grew a true pathogen. In each of these cases, other blood cultures taken in the same time frame or previously also grew the same pathogen. DISCUSSION IVCs frequently are used to administer chemotherapy, blood products, total parenteral nutrition, antibiotics, and many other medications. In addition to the administration of therapeutic agents, IVCs also are used to obtain blood samples to reduce the trauma associated with venipuncture. Although the preferred method for obtaining blood cultures is peripheral venipuncture (,), blood for culture increasingly is obtained from IVCs. Several methods of obtaining blood for culture via IVCs have been described. In the discard method, blood is aspirated into a syringe to clear the catheter of any residual intravenous solutions and medications, and is then discarded. A second sterile syringe is then used to obtain blood for culture. Blood immediately beyond the hub of an IV catheter is thought to be diluted by the IV or flush solution. The blood that is removed allows the vein to refill from the capillary bed, Downloaded from on September, 0 by guest

7 0 0 thereby allowing the lumen of the catheter to fill with blood more representative of the total venous circulation (). In some cases, the discard aliquot is described as removal of the first aspirate without flushing the catheter. In others, the discard aliquot is described as including an initial flush of the device and then withdrawal of a discard specimen. In our institution, the discard technique involved an initial flush. The discard method is used commonly. Seventy-five percent of pediatric bone marrow transplant units reported using the this method (). According to the Oncology Nursing Society s Access Device Guidelines (), the discard method is most commonly used in adults as well. An informal online survey recently confirmed that institutions using this method usually discard -0 ml of blood before inoculating culture bottles (Baron EJ, personal communication). MacGeorte et al reported that adult bone marrow transplant patients lost an average of. ml of blood per week not including the blood volume for diagnostic testing, assuming that ml of blood were discarded for each lab draw (). In severely ill, febrile patients blood cultures are done frequently, and discarding of -0 ml of blood at the time of each culture can result in significant blood loss and potential iatrogenic anemia which, in turn, can lead to transfusionassociated risks. Although Everts and Harding () reported no significant difference in Downloaded from on September, 0 by guest

8 0 contamination rates between first drawn and second drawn samples (.% vs..%), only blood cultures were evaluated. Our study, which has a substantially larger sample size, confirms the observation that discarding the initial aliquot of blood from an IVC-drawn blood culture does not reduce contamination rates. Despite recommendations to use peripheral venipuncture as the preferred method of obtaining blood for culture, sometimes for ease or for other reasons, blood is drawn through an IVC. Whereas we do not advocate IVC-drawn blood cultures, we recognize the reality that some will be obtained in this fashion. Since discarding the initial aliquot of blood may contribute to nosocomial anemia and does not reduce contamination rates, we believe this practice should be abandoned. Downloaded from on September, 0 by guest

9 0 0 REFERENCES. Baron EJ. 00. Blood cultures do not require discarding of first few ml of blood. ClinMicroNotes, published online Sept,00.. Baron E.J., M.P. Weinstein, W.M. Dunne, Jr., P. Yagupsky, D.F. Welch, and D.M. Wilson. 00. Cumitech C. Blood Cultures IV. Coordinating ed., E.J. Baron. ASM Press, Washington, D.C.. Barton, S., T. Chase, B. Latham, and M.K. Ravens. 00. Comparing two methods to obtain blood specimens from pediatric central venous catheters. J Pediatr. Oncol. Nurs.:0-.. Bryant, J.K. and C.L. Strand.. Reliability of blood cultures collected from intravascular catheter versus venipuncture. Am. J Clin. Pathol. :-. Camp-Sorrell, D. ed., 00. Access Device Guidelines: Recommendations for Nusring Practice and Education, nd ed., Oncology Nursing Society, Pittsburgh, PA.. Christman, J.F. and D.G. Doherty.. The antimicrobial action of heparin. J Bacteriol. :-.. CLSI. 00. Principles and Procedures for Blood Cultures; Approved Guideline. CLSI document M-A. Clinical and Laboratory Standards Institute, Wayne, PA.. DesJardin, J.A., M.A. Falagas, R. Ruthazer, J. Griffith D. Wawrose, D. Schenkein, K. Miller, and D.R. Snydman.. Clinical utility of blood cultures drawn from indwelling central venous catheters in hospitalized Downloaded from on September, 0 by guest

10 0 0 0 patients with cancer. Ann. Intern. Med. :-.. Everts, R.J. and H. Harding. 00. Catheter drawn blood cultures: is withdrawing the heparin lock beneficial? Pathol. : Everts, R.J., E.N. Vinson, P.O. Adholla, and L.B. Reller. 00. Contamination of catheter-drawn blood cultures. Pediatr. Infect. Dis. J. :-.. Holmes, K.R.. Comparison of push-pull versus discard method from central venous catheters for blood testing. J Intraven. Nurs. :-.. Keller, C.A.. Methods of drawing blood samples through central venous catheters in pediatric patients undergoing bone marrow transplant: Results of a national survey. Oncol. Nurs. Forum. :-.. MacGeorte, L., L. Steeves, and R.H. Steeves.. Comparison of the mixing and reinfusion methods of drawing blood from a Hickman catheter. Oncol. Nurs. Forum. :-.. Mohler M., Y. Sato, K. Bobick, L.C. Wise.. The reliability of blood sampling from peripheral intravenous infusion lines. J Intraven. Nurs. :0-.. Norberg, A., N.C, Christopher, M.L. Ramundo, J.R. Bower, and S.A. Berman. 00. Contamination rates of blood cultures obtained by dedicate phlebotomy vs. intravenous catheter. JAMA. :-.. Penwarden, L.M. and P.G. Montgomery. 00. Developing a protocol for obtaining blood cultures from a central venous catheters and peripheral sites. Clin. J Oncol. Nurs. :-0. Downloaded from on September, 0 by guest

11 0 0. Ruge, D.G., R.L. Sandin, S.A. Siegelski, J.N. Greene, and N. Johnson. 00. Reduction in blood culture contamination rates establishment of policy for central intravenous catheters. Lab. Med. :-00.. Thavendiranathan, P., A. Bagai, A. Ebidia, A.S. Detsky, and N.K. Choudhry. 00. Do blood tests cause anemia in hospitalized patients? The effect of diagnostic phlebotomy on hemoglobin and hematocrit levels. J Gen. Intern. Med. 0:0-.. Warren Jr, GF. 0 The effect of heparin on the growth of bacteria and yeast. J Bacteriol. 0:-. 0. Weinstein, M.P., M.L. Towns, S.M. Quartey, S. Mirrett, L.G. Reimer, G. Parmigiani, and L.B. Reller.. The clinical significance of positive blood cultures in the 0s: a prospective comprehensive evaluation of the microbiology, epidemiology, and outcome of bacteremia and fungemia in adults. Clin. Infect. Dis. :-0.. Wisser, D., K. Van Ackern, E. Knoll, H. Wisser, and T. Bertsch. 00. Blood loss from laboratory tests. Clin. Chem. :. Downloaded from on September, 0 by guest

12 Table. Frequency of contamination in blood inoculated into discard and standard culture vials Contamination in Discard Contamination in Standard Sample Sample Yes No Yes (.) a (.) No (.) (.% a Numerical data presented as No. (%) Downloaded from on September, 0 by guest