CoreVision. Advanced imaging solution. Overcome uncertainty. Treat confidently.

Size: px
Start display at page:

Download "CoreVision. Advanced imaging solution. Overcome uncertainty. Treat confidently."

Transcription

1 CoreVision Advanced imaging solution Overcome uncertainty. Treat confidently.

2 See with clarity Better visualize the anatomy with less effort Vessel Enhancement Visualize hazy, tortuous, and overlapping vessels and highly stenosed lesions. Potentially reduces the number of views saving time, radiation, and contrast. Go beyond the angiogram to further understand patient anatomy and disease ifr Co-registration Identify locations of ifr drops quickly to better understand diffuse vs. focal disease and know where the regions causing ischemia are located. IVUS Co-registration Map the 3D vessel anatomy to the angiogram to understand precisely where the disease begins and ends.

3 Plan with certainty Have confidence in your treatment decision ifr Co-registration Understand the potential impact of a stent on the patient s ischemia to estimate if a stent likely meets the procedural objectives. Determine precise stent sizing, length and location Calibrated QCA Quickly calculate lumen dimensions and stenosis to size the stent quickly and efficiently. ifr and IVUS Tri-Registration Easy length measurements that combine IVUS and ifr information with the angiogram to help determine if a stent will meet the procedural objectives.

4 Deliver with confidence Confidently execute the treatment plan Device Detection Enhances and stabilizes the device image to enable precise device placement with no additional radiation or contrast. Easily confirm inter-procedural objectives ifr Co-registration Easily confirm post-treatment ifr and the physiological impact of the intervention. IVUS Co-registration Confirm stent apposition and sizing.

5 An angiogram-centered approach for a higher level of diagnostic insight The CoreVision advanced imaging solution is the only system that offers the combination of advanced angiography, advanced IVUS, and advanced physiological imaging for the high level of diagnostic insight needed for today s increasingly complex patient populations. Procedural, financial, and patient benefits CoreVision is designed to: Enhance angiography with no additional radiation, contrast, time, labor or supply costs Help facilitate complex cases Help reduce geographic miss for better outcomes Help more accurately determine stent length to help avoid patchwork stenting Philips combines this set of advanced precision guidance tools Intravascular imaging Angio-centric imaging Physiology Plug and play IVUS Rotational IVUS OCT IVI co-registration with angiography Real-time, parallel enhancement of diagnostic angio (VE) One-click QCA Real-time image stabilization and enhancement of devices Physiology co-regisration with angiography ifr (hyperemia-free physiology) FFR Philips Boston Scientific ACIST Abbott Siemens GE

6 Specifications SyncVision Power requirements Dimensions Inputs Ordering information System input Bedside joystick Angio system video output IVUS system IVUS catheter ECG signal SyncVision system 100V-120V, 50/60Hz; V, 50/60Hz; 600 VA V, 50/60Hz; 250 VA V, 50/60Hz; 93 VA H: 16.5", 39.6 cm, W: 6.75", 16.2 cm, D: 21.25", 51 cm H: 1.5", 3.7 cm, W: 4.2", 10.7 cm, D: 3", 7.6 cm H: 15-19", cm, W: 15.8", 40.2 cm, D: 10", 24.7 cm Analog or digital s5/core systems, SW version and above Eagle Eye Platinum catheters Contact your local Philips representative for compatibility Sync002 Core integrated Power requirements Dimensions Processing and data storage Ordering information System input Control pad (optional) Control room controller Connection box Processor Memory Hard drive capacity Digital archiving options Dicom services supported 100, 120V, 220, 240VAC, 50/60Hz, 1000VA V, 50/60Hz, 825VA 100V 240V 50/60Hz, 39W H=17, W=10, D=16.5 H=2.75, W=10.5, D=8.3 H=5, W=15, D=10 H=15 19 (depending upon the stand extension), W=15.8, D=9.7 H=9.85, W=2.95, D= CPU processor 2.53 GHz, 8 core total, 1366 MHz BUS 8 GB SD RAM 1TB 7200 RPM SATA Local, DVD, DICOM network DICOM worklist management, DICOM store Core system CORE01, Control pad (optional) Bedrail mount mount CPADO1 MNTO1 MNTO Koninklijke Philips N.V. All rights reserved Trademarks are the property of Koninklijke Philips N.V. or their respective owners. D /A Philips 3721 Valley Centre Drive, Suite 500 San Diego, CA USA