1 B Applications 2015 EDITION

2 B Applications B Applications B1 Building Type Applications B1.1 LOGICWALL 3D Panel Layout B2 Typical Multi-Residential Panel Layout B3 Application Charts for: B3.1 Balustrades B3.2 Blade Columns B3.3 External Blade Walls B3.4 External Facade Walls B3.5 Internal Corridor Walls B3.6 Internal Partition Walls B3.7 Internal Party Walls B3.8 Lift Shafts B3.9 Retaining Walls and Basement Walls B3.10 Service Shafts B3.11 Stair Shafts This chapter of the Designer must be read in conjunction with all chapters of the Designer. Important legal statements on inside back cover.

3 B Applications Disclaimer: This section of the Designer is intended only by to represent good building practice. This section is not intended in any way by to represent all relevant information required on a project. It is the responsibility of those using, including but not limited to builders, designers, consultants and engineers, to verify that is suitable for use on a project. All diagram, plans and illustrations used in this section including any reinforcement shown are included for indicative and diagrammatic purposes only. It is the responsibility of those using to ensure that reference is made to the structural engineer s details for all diagrammatic and reinforcement requirements. B1 Building Type Applications is a permanent formwork for reinforced concrete walls. So wherever there is an application for reinforced concrete walls up to 250mm thick, is likely to be applicable. The particular application will be subject to engineering assessment. The best applications for are for building structures which utilise load bearing wall construction and call for high levels of fire and acoustic performance. For external applications, must be protected by an appropriate water proofing system. The applications outlined in this chapter, including all charts, are based upon LOGICWALL s most common applications in multi-residential medium rise buildings. B Applications Balustrades Blade Columns External Blade Walls External Facade Walls Internal Corridor Walls Internal Partition Walls Internal Party Walls Lift Shafts Retaining Walls Basement Walls * Service Shafts Stair Shafts * Alternatively Basement Walls can be constructed using REDIWALL, another product by. 13

4 B Applications B1.1 3D Panel Layout PANEL LAYOUT Components Key # Application Wall Size Chapter Section Page 1 Internal Party Walls 162 B3.7 2 Internal Corridor Walls 162 B3.5 3 Internal Partition Walls 120 B3.6 4 Balustrade Walls 150 B3.1 5 Lift Shaft 200 B3.8 6 Stair Shaft 200 B Service Shafts 162 B External Facade Walls 150 B Basement / Retaining Walls 262 B Blade Columns 262 B3.2 9 Peter Ellsmore & Associates Pty Ltd Ph: (02) Fax: (02) pea.wollongong@ellsmore.com.au web: P.O. Box 471 Wollongong NSW 2500 WALLING SOLUTIONS Tekla structures 14

5 Applications Applications B B WALLING SOLUTIONS DESIGNER DESIGNER

6 B Applications B2 Typical Multi-Residential Panel Layout PANEL SIZES 16

7 B Applications Note: To meet acoustic requirements a discontinuous stud wall in addition to the is required for walls where a kitchen or bathroom abuts a living / dining area or the like. 17

8 Detail #31 B Applications Balcony Wall Detail B3 Application Charts for: The charts in this section relate to the applications shown on the multi-residential 3D image in B1.1 of this chapter. B3.1 Balustrades Application Composition Walls Serving as a solid upstand or hand rail. Diagram 120mm or 150mm N/A N/A N/A N/A vary according to application N/A /240/180 N/A /240/180 N/A 18

9 B3.2 Blade Columns Application Composition D 262D A building element or wall section serving as a loadbearing element Diagram 162mm, 200mm or 262mm B Applications Acoustic Stand Alone N/A N/A N/A N/A Fire (FRL) Built into Firewall vary according to application Acoustic Fire (FRL) Stand Alone Built into exposed 1 side N* f / < 0.7 Firewall Nu /90/80 240/240/ /120/ /240/ D /120/ /240/ D /120/ /240/240 19

10 B Applications B3.3 External Blade Walls Application Composition External wall serving as an architectural, load bearing blade wall Diagram 150mm, 162mm, 200mm or 262mm N/A N/A N/A N/A vary according to application N/A N/A N/A N/A 240/240/180 N/A N/A N/A N/A 240/240/240 N/A N/A N/A N/A 240/240/240 N/A 200D 58 N/A N/A N/A 240/240/240 N/A 262D 62 N/A N/A N/A 240/240/240 N/A 20

11 B3.4 External Facade Walls External walls serving as bulding envelope. B3.4.1 Climate Zone 1, 2, 3 and 5 Application Composition B Applications * * External facade walls Diagram 120mm or 150mm with 10mm foil board insulation or equivalent furring channel and plaster board External Internal Climate Zone 1, 2, 3, 5 N/A N/A N/A N/A 90/90/90 2* * N/A N/A 240/240/ * N/A N/A 240/240/ * All LOGICWALL s are suitable as external envelope walls for climate zones 1-7 as the comes under clause (b) of table J1.50 of the (see fig G4.3) ( where the only space for insulation is provided by a furring channel, top hat section, batten or the like ) which reduces the required total R to 1.4 for climate zones 1 to 7. For further options and details on thermal systems for, refer to Section G4 - Thermal Insulation of this manual. 2* This applies to external walls less than 3 metres from boundary for external walls greater than or equal to 3 metres from boundary. The requirement is 90/60/30. 21

12 B Applications B3.4 External Facade Walls continued B3.4.2 Climate Zone 4 and 6 Application Composition * * External facade walls Diagram 120mm or 150mm with 30mm foil board insulation, furring channel and plaster board External Internal Climate Zone 4 & 6 N/A N/A N/A N/A 90/90/90 2* * N/A N/A 240/240/ * N/A N/A 240/240/ * All LOGICWALL s are suitable as external envelope walls for climate zones 1-7 as the comes under clause (b) of table J1.50 of the (see fig G4.3) ( where the only space for insulation is provided by a furring channel, top hat section, batten or the like ) which reduces the required total R to 1.4 for climate zones 1 to 7. For further options and details on thermal systems for, refer to Section G4 - Thermal Insulation of this manual. 2* This applies to external walls less than 3 metres from boundary for external walls greater than or equal to 3 metres from boundary. The requirement is 90/60/30. 22

13 B3.4 External Facade Walls continued B3.4.3 Climate Zone 7 and 8 Application Composition B Applications * * External facade walls Diagram 120mm or 150mm with 40mm foil board insulation, furring channel and plaster board External Internal Climate Zone 7 & 8 N/A N/A N/A N/A 90/90/90 2* * N/A N/A 240/240/ * N/A N/A 240/240/ * All LOGICWALL s are suitable as external envelope walls for climate zones 1-7 as the comes under clause (b) of table J1.50 of the (see fig G4.3) ( where the only space for insulation is provided by a furring channel, top hat section, batten or the like ) which reduces the required total R to 1.4 for climate zones 1 to 7. For further options and details on thermal systems for, refer to Section G4 - Thermal Insulation of this manual. 2* This applies to external walls less than 3 metres from boundary for external walls greater than or equal to 3 metres from boundary. The requirement is 90/60/30. 23

14 B Applications B3.5 Internal Corridor Walls Application Composition Walls separating sole occupancy units from common areas, lobbies and stair shafts. Diagram 150mm or 162mm 50 N/A 45 N/A 90/90/90 N/A N/A N/A 240/240/180 N/A N/A N/A 240/240/240 N/A 24

15 B3.6 Internal Partition Walls Application Composition B Applications Load bearing walls within sole occupancy units Diagram 120mm or 150mm N/A N/A N/A N/A 90/-/- Heating exposure both sides N/A /240/180 N/A /240/180 N/A 25

16 B Applications B3.7 Internal Party Walls B3.7.1 Habitable to Habitable Application Composition Wall separating sole occupancy units - Habitable to Habitable 162mm or 200mm N/A 50 N/A 45 90/90/90 N/A /240/240 N/A /240/240 N/A 26

17 B3.7 Internal Party Walls continued B3.7.2 Habitable to Wet Area / Wet Area to Wet Area Where Services are to be installed B Applications Application Composition Wall separating sole occupancy units - Habitable to Wet Area 120mm, 150mm, 162mm or 200mm with additional discontinuous wall construction - ie. 64mm stud wall with 20mm cavity and sheeted with a suitable wet area lining board (not less than 10kg/m 2 where there is no insulation in the cavity). Plumbing services must be installed within the discontinuous steel stud frame on wet area side of. Habitable Area Wet Area /90/90 N/A /240/180 N/A /240/240 N/A /240/240 N/A * To be achieved using verification methods compliant with section, FV5.2 27

18 B Applications B3.7 Internal Party Walls continued B3.7.3 Wet Area to Wet Area - No Services Application Composition Wall seperating sole occupancy units - Wet Area to Wet Area with no services 162mm or 200mm - refer to B3.7.2 for walls that require housing of services /90/90 N/A /240/240 N/A /240/240 N/A * To be achieved using verification methods compliant with section, FV5.2 28

19 B3.8 Lift Shafts Lift Shaft to Sole Occupancy Unit Application Composition B Applications D 262D Fig B3.8 Walls separating lift shafts from sole occupancy units Diagram 162mm, 200mm or 262mm LOGICWALL LIFT Use construction as per page 27 SOLE OCCUPANCY UNIT Slab 50 N/A 45 N/A 90/90/90 1 N/A /240/240 N/A /240/240 N/A 200D /240/240 N/A 262D /240/240 N/A 1 For lift shaft walls in basement carparks the FRL requirement is 180/120/

20 B Applications B3.8 Lift Shafts continued Lif Shafts to Common Area Application Composition D 262 Walls separating lift shafts from common areas and stair shafts Diagram 150mm, 162mm, 200mm or 262mm LIFT COMMON AREA Slab N/A N/A N/A N/A 90/90/90 2 N/A /240/180 N/A /240/240 N/A /240/240 N/A 200D /240/240 N/A 262D /240/240 N/A 2 For lift shaft walls in basement carparks the FRL requirement is 180/120/

21 B3.9 Retaining Walls and Basement Walls Application Composition D 262D A wall serving to retain earth or similar elements e.g- where a deep excavation has occurred or in a basement situation. Detail #7 Retaining Wall Slab Junction Diagram Option A 120mm, 150mm, 162mm, 200mm or 262mm B Applications Backfilled to engineers requirements Note: Appropriate water proofing system applied to back face of wall. N/A N/A N/A N/A vary according to application N/A 120 N/A N/A N/A N/A 240/240/180 N/A 150 N/A N/A N/A N/A 240/240/180 N/A 162 N/A N/A N/A N/A 240/240/240 N/A 200 N/A N/A N/A N/A 240/240/240 N/A 200D N/A N/A N/A N/A 240/240/240 N/A 262D N/A N/A N/A N/A 240/240/240 N/A Alternatively basement or retaining walls can be constructed using REDIWALL, another product of. 31

22 B Applications B3.10 Service Shafts Application Composition Walls separating ventilation/ service risers from sole occupancy units or common areas Diagram 120mm or 150mm N/A 25 - Service shaft to Wet Area 40 - Service shaft to Habitable N/A N/A 90/90/90 1 N/A /120/120 N/A /240/180 N/A 1 For service shaft walls in basement carparks the FRL requirement is 180/90/90. 32

23 B3.11 Stair Shafts Application Composition B Applications Fig B3.11 Walls separating stair shafts from sole occupancy units or common areas Diagram 150mm, 162mm, 200mm SOLE OCCUPANCY UNIT System on page 29 recommended to provide impact insulation STAIR SHAFTS Slab 50 N/A N/A N/A 90/90/90 1 N/A /240/180 N/A /240/240 N/A /240/240 N/A 1 For stair shaft walls in basement carparks the FRL requirement is 180/120/

24 B Notes B Applications 34

25 B Applications 35

26 B Applications 36

27 B Legal Statements IMPORTANT LEGAL STATEMENTS Reasonable efforts have been made to ensure the accuracy of this publication; however, any information and data contained herein is subject to change without notice. To ensure the information you are using is correct, recommends you review the latest technical information available on the website or alternatively call to speak to a Technical Representative. The logo and LOGICWALL mark are registered trade marks Systems Pty Ltd. No part of this publication may be reproduced in any form or by any means without prior written permission from Systems Pty Ltd. All rights reserved. B Applications DISCLAIMER 1. This technical manual named Designer together with the design tables and associated information related to has been prepared by to assist design professionals using LOGICWALL including without limitation, developers, builders, engineers, architects or quantity surveyors with the design of structural walls. 2. It is the responsibility of the user to ensure that the use of this manual is appropriate and to exercise their own judgment when using this manual. 3. does not accept any responsibility (whether for negligence or otherwise) for any consequence arising from the use or application of this manual. 4. The design and engineering of the structure of any building using should only be undertaken by suitability qualified and experienced design professionals, engineers or consultants. 5. The full responsibility for the design, engineering and structural design, and certification of compliance with all relevant Australian Standards, and any other statutory requirements at Local, State and Federal levels rest with the design professional, project engineer or project consultants including but not limited to the design engineer, acoustic consultant, energy efficiency consultant, fire engineer and any of their officers, employees, delegates, partners, agents and service providers of any nature. 6. reserves the right to change the specifications of this manual without notice. 7. Please check with that you have the latest version as the manual may be updated from time to time and certain details may change. 8. This disclaimer applies to the extent permitted by law. DEFINITIONS The use of the terms and Walls throughout the Designer are as follows; : Refers to panels as permanent formwork prior to being installed & corefilled with concrete. Walls: Refers to walls installed with concrete corefill incorporated. W

28 Distributed by: SYSTEMS PTY LTD PO Box 234, Minto NSW Airds Road, Minto NSW 2566 Phone: Web: ABN IMPORTANT LEGAL INFORMATION Reasonable efforts have been made to ensure the accuracy of this publication; however, any information and data contained herein is subject to change without notice. To ensure the information you are using is correct, recommends you review the latest technical information available on the website or alternatively call to speak to a Technical Representative. The logo and LOGICWALL mark are registered trade marks Systems Pty Ltd. No part of this publication may be reproduced in any form or by any means without prior written permission from Systems Pty Ltd. All rights reserved.