Prestige Series 12. Installation guide

Size: px
Start display at page:

Download "Prestige Series 12. Installation guide"

Transcription

1 Prestige Series 12 Installation guide PIONEERING INSULATED METAL PANEL TECHNOLOGY

2 CONTENTS Section Page Notes to Designer/User Panel Options Panel Details Accessories Drip/Soffit Flashing Soffit End Splice Horizontal End Splice End Wall Inside Corner Outside Corner Sill/Vertical End Splice Door/Window Trim (Head) Door/Window Trim (Jamb) Door/Window Trim (Sill) Parapet Cap

3 Notes to Designer/User The installation details contained in this packet are only intended to be a design aid. Actual conditions will vary and all situations have not been taken into account. Modifications to suit actual conditions will be the responsibility of the designer/user. Standard flashings are depicted in the details. Metl-Span can manufacture other styles to suit your specific project conditions and aesthetic needs. The Prestige Series (PS-12) is a family of concealed fastener panels used for wall, soffit, fascia, and equipment screen applications. It can be installed vertically or horizontally and is available in a number of different reveals and finishing options to provide maximum design flexibility. The Prestige Series can be used over solid substrates or over open framing. The details in this booklet are shown over a solid substrate (plywood). Details are generally the same for either solid substrate or over open framing conditions except for a change in fastener type. The designer/user is responsible for adjusting dimensions and details as required to meet specific project conditions. Maximum Panel Lengths: 18ga 20ga 22ga 24ga 45ft 40ft 35ft 30ft Prestige Series panels are also available perforated. Metal soffit and wall panels may be susceptible to condensation, and its control should be carefully considered. It is the designer/user s responsibility to determine the need and type of condensation control material (insulation, vapor retarders and/or venting). Special notes for horizontal panel installations: Due to the natural tendency for panels to sag and oil can, horizontal applications are limited to 22ga and heavier panels. Horizontal applications require panels to be installed top down (eave to foundation). Contact your Metl-Span representative if you have any questions about the use or installation of Prestige Series panels, flashings, and accessories. To assist in conditions that require weathertight installations, the Prestige Series comes with a factory-applied sealant as the standard product offering. Heavier gauge panels (22ga or heavier) are recommended to reduce the tendency for oil-canning. In applications where a higher resistance to wind loads is needed, it is recommended that the optional retainer clip be used to prevent panel separation. 2

4 Panel Options Full 1 Panel OPTIONS: FLAT FINISH 1 RIB (CENTERED) 2 RIBS (SPACED 4") WAVE PATTERN 11 Up / 1 Down Panel OPTIONS: FLAT FINISH 1 RIB (CENTERED ON UP SIDE) 2 RIBS (SPACED 4") 10 Up / 2 Down Panel OPTION: FLAT FINISH 1 RIB (CENTERED ON UP SIDE) 2 RIBS (SPACED 4") 6 Up / 6 Down Panel OPTIONS: FLAT FINISH 1 RIB (1 CENTERED ON EACH UP/DOWN HALF) Note: Offering is current as of the publish date of this installation guide. Please note that panel offering is subject to change. 3

5 Panel Details PANEL WITH REVEAL SHOWN (10 UP/ 2 DOWN) SEALANT (STANDARD OFFERING) 1 (FULL) PANEL WITH 2 PENCIL RIBS SHOWN SEALANT (STANDARD OFFERING) OPTIONAL RETENTION CLIP SHOWN 4

6 Accessories Outside Closures 11 UP 10 UP 6 UP FULL Inside Closures 11 UP 10 UP 6 UP Retention Clip 5

7 Drip/Soffit Flashing 6" 3" 6" 4" 4" C-Metal Drip Drip (Optional) 30# FELT MINIMUM UNDERLAYMENT OR OTHER MEMBRANE AS REQUIRED PANEL FASTENER PS-12 WALL PANEL INSIDE CLOSURE (SEALED & SECURED WITH SEALANT) DRIP FLASHING PS-12 SOFFIT PANEL C-METAL FLASHING BUTYL SEALANT CONTINUOUS BEAD BETWEEN FLASHING & PANEL FASTENER W/NEOPRENE WASHER OR RIVET AT 1 O.C. MAXIMUM 6

8 Soffit End Splice 3" 3" 3" End Splice C-Metal PS-12 SOFFIT PANEL BUTYL SEALANT CONTINUOUS BEAD BETWEEN FLASHING & PANEL END SPLICE FLASHING FASTENER W/NEOPRENE WASHER OR RIVET AT 1 O.C. MAXIMUM REVEAL FLASHING C-METAL (TYPICAL) DIMENSION MAY VARY TO MEET PROJECT CONDITIONS 7

9 Horizontal End Splice 3" 1" 1" C-Metal Cover Trim BACK FLASHING, 24GA MIN CONTINUOUS BEAD OF BUTYL MASTIC OR MASTIC TAPE C-METAL, 24GA MIN ANGLE COVER TRIM FOR CLOSURE OUTSIDE CLOSURE (SEALED & SECURED WITH SEALANT) FASTENER W/NEOPRENE WASHER OR RIVET AT 1 O.C. MAXIMUM PS-12 PANEL 8

10 End Wall 3" 1" 1" Z-Metal C-Metal Cover Trim C-METAL, 24GA MIN. VERTICAL INSTALL Z-METAL, 24GA MIN. PS-12 PANEL HORIZONTAL INSTALL BUTYL SEALANT- CONTINUOUS BEAD BETWEEN FLASHING AND PANEL FASTENER W/NEOPRENE WASHER OR RIVET AT 12 O.C. MAXIMUM OUTSIDE CLOSURE (SEALED & SECURED WITH SEALANT) COVER TRIM FOR CLOSURE 9

11 Inside Corner 4" 1 1/4" (3 PL) 4" Inside Corner Z-Metal Z-Metal, Small VERTICAL INSTALL Z-METAL, SMALL DETAIL SHOWN WITH BOTH FULL AND REVEAL PANEL OPTIONS. FIELD-CUT PS-12 PANEL AS REQUIRED TO FIT CORNER INSIDE CORNER FASTENER W/NEOPRENE WASHER OR RIVET AT 1 O.C. MAXIMUM BUTYL SEALANT CONTINUOUS BEAD BETWEEN FLASHING AND PANEL (3 PLACES) Z-METAL, 24GA MIN. HORIZONTAL INSTALL OUTSIDE CLOSURE (SEALED & SECURED WITH SEALANT) ANGLE COVER TRIM FOR CLOSURE 10

12 Outside Corner 4" 1 1/4" (3 PL) 4" Outside Corner Z-Metal Z-Metal, Small FIELD-CUT PS-12 PANEL AS REQUIRED TO FIT CORNER Z-METAL 24GA MIN. VERTICAL INSTALL OUTSIDE CORNER FASTENER W/NEOPRENE WASHER OR RIVET AT 1 O.C. MAXIMUM BUTYL SEALANT CONTINUOUS BEAD BETWEEN FLASHING AND PANEL (3 PLACES) DETAIL SHOWN WITH BOTH FULL AND REVEAL PANEL OPTIONS. HORIZONTAL INSTALL OUTSIDE CLOSURE (SEALED & SECURED WITH SEALANT) ANGLE COVER TRIM FOR CLOSURE 11

13 Sill/Vertical End Splice 6" Z-Metal End Splice/Sill VERTICAL INSTALL PS-12 WALL PANEL INSIDE CLOSURE (SEALED & SECURED WITH SEALANT) END SPLICE/SILL FLASHING FASTENER W/NEOPRENE WASHER OR RIVET AT 1 O.C. MAXIMUM BUTYL SEALANT CONTINUOUS BEAD BETWEEN FLASHING AND PANEL PS-12 WALL PANEL OR OTHER EXTERIOR MATERIAL (STUCCO, ETC.) HORIZONTAL INSTALL 12

14 Door/Window Trim (Head) 6" Z-Metal 4" Door/Window Trim VERTICAL INSTALL PS-12 WALL PANEL INSIDE CLOSURE (SEALED & SECURED WITH SEALANT) SEALANT BETWEEN FLASHING & FRAME DOOR/WINDOW FRAME DOOR/WINDOW TRIM HORIZONTAL INSTALL 13

15 Door/Window Trim (Jamb) 3" 4" C-Metal Z-Metal Door/Window Trim VERTICAL INSTALL DOOR/WINDOW FRAME SEALANT BETWEEN FLASHING & FRAME DOOR/WINDOW TRIM PS-12 WALL PANEL Z-METAL, 24GA MIN. BUTYL SEALANT CONTINUOUS BEAD BETWEEN FLASHING AND PANEL HORIZONTAL INSTALL FASTENER W/NEOPRENE WASHER OR RIVETS AT 1 O.C. MAXIMUM OUTSIDE CLOSURE (SEALED & SECURED WITH SEALANT) ANGLE COVER TRIM FOR CLOSURE 14

16 Door/Window Trim (Sill) 3" 4" C-Metal Door/Window Trim Z-Metal DOOR/WINDOW FRAME VERTICAL INSTALL SEALANT BETWEEN FLASHING & FRAME DOOR/WINDOW TRIM FASTENER W/NEOPRENE WASHER OR RIVET AT 1 O.C. MAXIMUM BUTYL SEALANT CONTINUOUS BEAD BETWEEN FLASHING AND PANEL PS-12 WALL PANEL HORIZONTAL INSTALL 15

17 Parapet Cap 8" (OR AS REQ D) 4 3/4" 2 1/ Parapet Cap Continuous Cleat (Optional) VERTICAL INSTALL PARAPET CAP CONTINUOUS CLEAT PANCAKE HEAD FASTENER OR RIVET AT 1 O.C. MAXIMUM SEALANT BETWEEN FLASHING & PANEL (OPTIONAL) PS-12 WALL PANEL HORIZONTAL INSTALL 16

18 1720 Lakepointe Drive, Suite #101 Lewisville, Texas Toll-free: Tel: PIONEERING INSULATED METAL PANEL TECHNOLOGY Fax: Web: metlspan.com 2012 Metl-Span LLC - All rights reserved. Printed in the U.S.A. METL