MSP Modular Building System

Size: px
Start display at page:

Download "MSP Modular Building System"

Transcription

1 Temporary & Emergency Residential Accommodation State of the art design & building technology

2 Multiple Applications Residential, Hotel, Care Home, Student Accommodation

3 Multiple Applications Residential, Hotel, Care Home, Student Accommodation Retail Restaurant Clinic - Office Sports facilities Bathrooms - Flexibility Can be combined any way over three storeys high State of the art design & building technology

4 Quick & Easy Transport Flat Pack Delivery Up to 4 pod cabins per 40 trailer MSP These pods are delivered to site as flat pack or as made up modules, thus enabling several units to be delivered at once. Our team of experienced site operatives will unload and assemble the modules, creating ISO standard new work corner & living & forklift space in the fraction of the time of a conventional new pockets build. N.B. Sites must be accessible for container delivery trucks and mobile cranes. Quick & Easy Transport

5 Fast Construction Quick assembly one pod cabin can be completed within 2 hours MSP London Bridge, London SE1 1LB

6 Residential Studios & Family Apartments 2 Bedroom Layout GEA 59.3 m² London Bridge, London SE1 1LB

7 Retail Restaurant Clinic- Office MSP London Bridge, London SE1 1LB

8 Multiple Applications Retail Restaurant Clinic - Office Sports facilities Bathrooms - London Bridge, London SE1 1LB

9 My Space Pod Bathroom & Kitchen fixtures: Kitchenette Kitchen cabinet (1000mm X600mm) with Overhead cupboards Stainless steel washbasin and drainer mixer tap Electric hob Fridge freezer Microwave Instant electric hot water. Bathroom En-suite WC dual flush, Wash hand basin & Aerated Mixer tap Shower cubicle, shower mixer Aerated shower heads, flow rate bar, Instant electric hot water. DDA compliant WC unit

10 CX FLAT PACK POD MSP Full Specifications As a result of using the most advanced insulation and building materials, the Pods are designed and engineered to meet CEE & British Standard building regulation codes and guides. The pods are self-supporting to build 3 storey high buildings, and with additional steel framing can be formed into 6 storey buildings. The individual pods achieve the following technical specification standards. My Space Pod Building Fabric: Heat loss U Values: Roof 0.19 (W/m2K); Floor 0.20; External Wall 0.22; Party Wall Heat loss U Values: Entrance Door 2.2, Heat loss U Values : Windows, Low E double glazed 1.9 W/m2K. Fire safety- All walls & ceiling at least 30' fire resistant. Acoustic -internal noise reduction, Site specific TBA. My Space Pod Basic items included: Steel entrance door 825mm Clear opening width, heavy duty lock mechanism UPV Double glazed gas filled windows with aluminium roller shutters. Hi-Tec vinyl / laminate flooring for easy cleaning & hygiene Electrical item (220V/50Hz) 1 distribution box with breakers Electric panel heating Low energy lighting & ample power sockets, Telephone, TV sockets Smoke alarm detectors. Linking kits & CEE Cable

11 Additional Optional Ground Support Services MSP Subject to site specific ground conditions it is possible to use Jack Pad Ground Support Foundation Pads N.B All sites must have mains services connections and ground works ready in situ including any foundations or hard standing surfaces.

12 Additional Optional Specification External Cladding MSP Weatherboard Cladding My Space Pod Optional External items: External Cladding Composite Timber Cladding Brick slip Trespa panel Brick Slip Cladding effect

13 Additional Optional Specification Speed Deck - Roofing System MSP Pitched or Flat Roof Fabricated Spanning Truss SpeedDeck s Fabricated Spanning Truss system provides a lightweight pitched roof construction which is quick to install, cost effective and can offer a clear span up to 26 metres. The spanning truss is manufactured off-site and delivered to be installed by our experienced roofing contractors. This type of system has been primarily used in volumetric or modular constructions of Social housing, Residential, Education, MOD and Prison projects. The system can be tailored to suit the various module sizes in the market place, ensuring that frame centres are positioned above the perimeter of each module, to be anchored back into the cold rolled channel edge beam generally provided in the module frame. The system has been engineered to incorporate a maximum amount of adjustment, accommodating any amount of level variance, and has been designed to suit any of our metal roofing systems manufactured in both steel & aluminium. Single skin roof construction are generally specified in the modular / volumetric market sector as the insulation zone is within the module itself, therefore noise dampening and anti-condensation membranes should be considered to the reverse of the roofing system. The system is erected to meet the Building Regulations 1991 (England and Wales) Standard. In the design of the system all current codes of practice are considered and proved by calculation:

14 DIMENSIONS (mm) AND WEIGHTS (kg): TYPE EXTERNAL INTERNAL Length Width Height *1 Length Width Height *2 Weight Weight (Fully assembled) ( Fully assembled) (Flat packaging) BM 10' 2,989 2,435 2,591 2,795 2,240 2,200-2,340 from 1,290 from 1,350 BM 16' 4,885 2,435 2,591 4,690 2,240 2,200-2,340 from 1,690 from 1,750 BM 20' 6,055 2,435 2,800 5,860 2,240 2,450-2,540 from 1,930 from 1,990 BM 24' 7,355 2,435 2,800 7,140 2,240 2,450-2,540 from 2,250 from 2,310 BM 30' 9,120 2,435 2,800 8,925 2,240 2,450-2,540 from 2,710 from 2,770 *1, Also available HC External Height 2,960 internal height up to 2,700 *2, Depending on level of Insulation required Additionally we offer 16'/24' corridor cabins and staircase cabins - details upon request RAL9002 Grey White RAL1018 Zinc Yellow RAL5010 Gentian Blue RAL7035 Light Grey Flexible Modular Pods 4 Colours available

15 Made in Europe Certificates according to CEE manufacturing codes Multiple Applications