Grüv 2.5" Recessed Linear LED

Size: px
Start display at page:

Download "Grüv 2.5" Recessed Linear LED"

Transcription

1 Features Small in scale, big on performance: Grüv 2.5" LED, 5 or 10 watts/foot, delivers superior performance that makes it ideal for ambient lighting in ceiling and wall applications. t only 2.5" in width and less than 6" in depth: and providing superior visual aesthetic with snap-in hybrid micro-linear lens Grüv 2.5" LED is big enough for ambient lighting and small enough to add visual accent to your designs. Product Overview Type: Recessed Direct Wattage: 5W/ft, 10W/ft (other Wattages available see p2) Lumen Output: 3,662 max; 92.1 Lm/W (10W, 4ft fixture) Color Temp: 2700K, 3000K, 3500K, 4000K CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) Dimming: 0-10V, 1% dimming (standard) Lutron Hi-lume 3 wire, 1% dim Lutron Hi-lume EcoSystem, 1% dim Lutron Hi-lume 2 wire (120V only) Lutron Hi-lume EcoSystem, 1% dim, fade to off Lutron Hi-lume 5 Series DLI dimming, 0.1% dim 5 Fixture Summary (see following pages for more information) Ceiling Types 4" Tech Zone 6" Tech Zone 9/16" 15/16" Gyp oard Millwork No No Yes Yes Yes Yes Perimeter J-Mold Yes Performance Chart Wattage Per Foot Delivered Lumens LPW Color Temp 5 1, K 10 3, K Data is based on 3500K-83 IES files available on website Data is based on 4' fixture with performance lens Electrical Data 4' 8' Wattage Per Foot 5 System Watts mps System Watts mps 120V V V V Electronic multi-volt (120V-277V), constant current LED driver Standard Patterns " " " " Wall to Ceiling Custom* Yes Yes Yes Yes Yes Yes Yes " " " " " " * Submit drawing, consult factory LIT /14/18 Page 1 of 12

2 Ordering Information HW 120/ Model GRUV2.5-FLG-16 - exposed flange GRUV2.5-FLG-GRID-16 - flange, grid mount GRUV2.5-G-16 - gyp board trimless mud-in GRUV2.5-GRID-16 - grid mount GRUV2.5-IS-16 - independently suspended, millwork GRUV2.5-J/G-16 - j-mold/gyp board trimless GRUV2.5-J/GRID-16 - j-mold/grid GRUV2.5-J/IS-16 - j-mold/independently suspended Optics PL - performance lens (standard) DL - designer lens Wattage (per foot) Standard: 5-5W/ft 10-10W/ft Optional: 3-3W/ft (4' minimum length required) 4-4W/ft (4' minimum length required) 6-6W/ft 7-7W/ft 8-8W/ft 9-9W/ft Color Temp 83 CRI: K K K K CRI optional, consult factory Finish HW - high reflectance matte white Voltage 120/277 Length x x (Length ) (Length ) (Length C) Length (used for) Length (used for) Length C (used for) - all patterns - all patterns - PU - IND/IND-S+ - PR - 2 lengths - PZ - CON/CON-S+ of 2 - CUS Configuration IND 1 - individual fixture, 2' to 8' in 1' increments IND-S+ - individual with standard plus (see pg7, not for Flanged versions) CON - continuous run > than 8', specify to nearest foot CON-S+ - continuous run with standard plus (see pg7, not for Flanged versions) CUS - custom made to measure, +/- 1/8" of customer supplied field dimensions Standard Patterns (see page 8 for details): PLL - L left, (2) straights + (1) 90 corner, leg right PLR - L right, (2) straights + (1) 90 corner, leg left PU - U shape, (3) straight lengths + (2) 90 corners PR - Rectangle, (4) straight lengths + (4) 90 corners PZ - Z shape, (3) straight lengths + (2) 90 corners PWC - wall to ceiling (1) 90º Corner joining 2 segments Custom Patterns: PC - please provide drawings and consult factory Drivers 0-10V - 1% electronic dimming, multi-volt (120V-277V) constant current driver (standard). HILUME--DH - Lutron "" Series, 1% dim, 3-wire (Dim Hot) HILUME--ECO - Lutron "" Series, 1% dim, EcoSystem HILUME--LTE - Lutron "" Series, 1% dim, 2-wire, 120V only HILUME-H-ECO - Lutron "H" Series, 1% dim, fade to off, EcoSystem HILUME-5-ECO - Lutron "5" Series, EcoSystem DLI - DLI Dimming 120V-277V, 0.1% dim Options/ccessories CP - Chicago Plenum (CCE) ENLS - Enlighted Sensor (0-10Vonly and not available on 2' & 3' lengths) WHIP - 6' whip, 18/5 conductor EMC-PF 2 - emergency circuit requires power feed located in last fixture section (for other locations consult factory) PF 2 - Extra power feed for additional circuiting 1 - Lengths less than 4' may have restrictions based upon wattage, lengths, drivers or other options. 2 - Not available with IND (individual) configuration. The "" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not changing the overall fixture aesthetic and are reflected in the published performance data. Please contact your merlux representative for explanations of changes. LIT /14/18 Page 2 of 12

3 Specifications pplication Commercial and retail recessed ambient lighting can be customized with made to measure lengths, patterns, ceilings or wall mounted fixtures. Construction One piece extruded aluminum housing and trim. Die-formed, coldrolled steel internal components and external mounting brackets. Numerous configurations accommodate most architectural ceiling conditions. Optical ll lenses are snap-in, extruded acrylic, with a maximum length of 8. merlux's proprietary acrylic lens provides excellent transmission while effectively concealing source image. PL - Performance Lens provides high efficiency with controlled lens surface brightness (standard). DL - Designer Lens provides flat even glow on lens. est when lens is in direct or constant view. Such as vertical wall mounted. LED merlux's boards and patented connector design with brand name LEDs enables merlux fixtures to have excellent thermal management and offer a 5 year warranty. Our LED binning is within 3 Macdam ellipse. oards are configured for maximum flexibility resulting in even illumination no matter the fixture layout. LED boards are easily replaced in the field with just a Phillips screw driver. Color Temperature Options: 2700K, 3000K, 3500K, 4000K CRI: 83 typical, 92 optional - consult factory R9: CRI 83 R9: CRI 92 Life: 50,000+ hr., > 70% of initial lumens (L70) Electrical Wiring: Supply wires are easily accessible through access plate on top of fixture. WHIP: Optional factory installed 6' Greenfield whip (18/5 conductor) simplifies installation. Standard Wattage: 5W/ft, 10W/ft. Optional Wattages: 3W/ft, 4W/ft, 6W/ft, 7W/ft, 8W/ft, 9W/ft. (3W & 4W have a minimum length of 4'). For other wattages consult factory. Emergency circuit via remote inverter or auxiliary emergency power supply. This product complies with IEEE C62.41 for surge endurance up to 2.5KV. merlux recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. EMC-PF - Emergency circuit requires power feed wire harness to be located in last fixture section for continuous runs. For other locations consult factory. Not available for individual (IND) configuration. PF - Extra power feed wire harness for additional circuiting. Not available for individual (IND) configuration. Drivers 0-10V - 1% electronic dimming, multi-volt (120V-277V) constant current driver (standard). Cap leads for non-dim applications. Optional Drivers: HILUME--DH - Lutron "" Series, 1% dim, 3-wire (Dim Hot) HILUME--ECO - Lutron "" Series, 1% dim, EcoSystem HILUME--LTE - Lutron "" Series, 1% dim, 2-wire, 120V only HILUME-H-ECO - Lutron "H" Series, 1% dim, fade to off, EcoSystem HILUME-5-ECO - Lutron "5" Series, EcoSystem DLI - DLI Dimming 120V-277V, 0.1% dim Finish HW - High reflectance, matte white powder coat paint. aked on finish for maximum durability and color stability. Configurations/Lengths IND - Individual fixtures are made of single standard lengths of 2 ft to 8 ft (in 1' increments). These are stand alone fixtures with matching End Caps, supplied with the mounting hardware. Lengths less than 4' may have restrictions based upon wattage, lengths, drivers or other options. CON - Continuous runs, > 8', specified to nearest whole foot length in 1' increments. Runs made from standard lengths have End Caps at the beginning and end of run. Runs > 60' may require second power feed. Each Housing has factory installed alignment pins. Mating fixtures are easily aligned and joined with "catch and latch" mechanisms out of sight, on top of the Housing. Wiring is made fast and positive with molded quick connectors. S+ - Standard Plus is a field cuttable filler bracket that can be used when an Individual fixture or a Continuous run isn't to the nearest foot (+3/4" to 6" max per end). See page 7 for details. CUS - Custom made yo measure runs are made to nearest 1/8"of customer supplied field measurements or drawings. Custom lengths use the same hardware for hairline joining. PXX - Standard Patterns consist of 90º corners with standard lengths (4' to 8' in 1' increments), continuous runs or made to measure lengths. Depending upon complexity of the pattern drawings may be required from the Customer. If ordering please give overall lengths. '-'-PLL - L Left - (1) 90º Corner 2 segments. Specify overall segments: & '-'-PLR - L Right - (1) 90º Corner 2 segments. Specify overall segments: & '-'-PR - Rectangle - (4) 90º Corners joining 4 segments. Specify overall segments: & '-'-C'-PU - U shape - (2) 90º Corners joining 3 segments. Specify overall segments:,, & C '-'-C'-PZ - Z shape - (2) 90º Corners joining 3 segments. Specify overall segments:,, & C '-'-PWC - Wall to Ceiling - 90º joining bracket. Specify overall segments: & See page 8 for layouts. PC - Custom Patterns may use standard lengths, Made To Measure, 90º or other corners (some limitations). Please provide drawing and consult factory. Please note: Corners have lit mitered Lens. Mounting Intended for use in gypsum board, 9/16" Tee grid, 9/16" Screw Slot and millwork ceilings. Wall mounting J-Molding details available. For individual, continuous row, or pattern applications. Please note - fixtures to be installed before gypsum board ceiling. GRUV2.5-FLG-16 - exposed flange, fixture into gyp board ceiling GRUV2.5-FLG-GRID-16 - exposed flange grid mount, fixture in 9/16" Tee ceilings. Consult factory for 15/16" ceilings. GRUV2.5-G-16 - gyp trimless mud, fixture plastered in gypsum board ceiling GRUV2.5-GRID-16 - grid mount, in 9/16" Screw Slot or Flat Tee ceilings GRUV2.5-IS-16 -independently suspended, fixture in wood ceiling GRUV2.5-J/G-16 - J mold/gyp trimless, plastered in ceiling - J Channel wall side GRUV2.5-J/GRID-16 - J mold/grid, in 9/16" Screw Slot or Flat Tee ceiling - J Channel wall side GRUV2.5-J-IS-16 - J mold/independently suspended in ceiling - J Channel wall side Certifications pproved to UL standards for damp locations as tested by CS Intended for indoor use only Chicago Plenum (CCE) optional Warranty merlux's 5 year limited warranty. Please consult merlux website for details. LIT /14/18 Page 3 of 12

4 GRÜV2.5-FLG (exposed flange) NOTE: Minimum ceiling opening must be held by installer for the full length of the run Support method 3 Mounting rods & hardware Suspension brackets (supplied by merlux) 3 9 /16" 5 3 /8" (optional) 1' to 2' 3" (default) Lens Finished wall line Lens Finished ceiling line Ceiling/Wall Corner (when required) 5/8" 3 1 /2" GRÜV2.5-FLG-GRID (flange, grid mount) 3 Mounting rods & hardware Suspension brackets (supplied by merlux) 15/16" Flat Tee (default) (optional) 1' to 2' 3 1 /16" 15/16" Flat Tee 3 9 /16" 3 1 /2" 4" 9/16" Slot-Grid Tee Tile resting on fixture 9/16" Flat Tee GRÜV2.5-G (gyp board trimless mud-in) Compatible (see pg 7) Support method 5/8" /4" Mounting rods & hardware Suspension brackets (supplied by merlux) 3 5 /8" Fixture height 5 7 /16" Fixture & mounting bracket height NOTE: Minimum ceiling opening must be held by installer for the full length of the run (default) (optional) 1 5 /16" 1' to 2' 3" 1/16" Ceiling contractor to spackle, feather & sand at ceiling interface. LIT /14/18 Page 4 of 12

5 GRÜV2.5-GRID (grid mount) Compatible (see pg 7) 1/4-20 olt, L Washer and Nut (supplied by merlux) Fold out seismic clip (2) per fixture 5" Ref (Support) 3 1 /16" Power Feed Ø 7 /8" 3 7 /8" 3 5 /8" 9/16" Flat Tee 2 11 /16" 3 5 /16" 9/16" Slot Grid Tee 5/16" Grid center to center GRÜV2.5-IS (independently suspended) Compatible (see pg 7) 5" max 3 5 /8" Mounting hardware Suspension/alignment brackets (supplied by merlux). Secure to structure djust 1 /2" - 2" (default) to 1' 3" Specify 1/8" 2 11 /16" 3/32" GRÜV2.5-J/G (j-mold/gyp board trimless) Compatible (see pg 7) 1/4-20 olt, L Washer and Nut (supplied by merlux) 3 7 /8" Support method 5/8" Support method 2 11 /16" This dimension must be held by installer for the full length of the run Hardware 1 11 /16" 3/8" 1 11 /32" "J" Channel racket (by merlux) "J" Channel (by merlux) (default) (optional) 1" to 2" 3" 3/32" Ceiling contractor to spackle, feather & sand at ceiling interface. LIT /14/18 Page 5 of 12

6 GRÜV2.5-J/GRID (j-mold/grid mount) Compatible (see pg 7) 1/4-20 olt, L Washer and Nut (supplied by merlux) Fold out seismic clip (2) per fixture 3 5 /8" 1 3 /4" Support method Hardware 1 11 /16" 3 5 /16" + 1 /16" -0" from wall 9/16" Flat Tee (tegular tile) (default) (optional) 4 1 /2" 3" 9/16" Slot-Grid Tee This dimension must be held by installer for the full length of the run 2 11 /16" /16" 1 /16" -0" 3/8" "J" Channel racket (by merlux) "J" Channel (by merlux) 5/16" 3 1 /2" + 1 /16" -0" from wall 15/16" Flat Tee 5/16" 3/32" GRÜV2.5-J/IS (j-mold/independently suspended) Compatible (see pg 7) Suspension/alignment brackets (supplied by merlux) Secure to structure Support method 5" max 3 5 /8" 2" max Mounting hardware Hardware 1 11 /16" to 1' 3" 2 11 /16" 5/16" 3/8" "J" Channel racket (by merlux) "J" Channel (by merlux) 3/32" LIT /14/18 Page 6 of 12

7 STNDRD PLUS (FILLER): Whenever a continuous run is less than a foot to the next full foot length consider ordering Standard Plus field cuttable bracket for a perfect look. Fits gypsum board, 9/16" Slot Grid and 9/16" T grid. It snaps in place easily from below and gets you close to the wall with a standard fixture. Saves time and money compared to made-to-measure. GRID VERSION GYP VERSION NOTE: Use with Gruv2.5-G, Gruv2.5-Grid, Gruv2.5-IS, Gruv2.5-J/G, Gruv25-J/Grid and Gruv1.5-J/IS FILLER TRIM ND INSTLLTION (GRUV 1.5 GRID SHOWN HERE) J channel Shadow, angle or other molding - 1/16 Ceiling tee Install fixture in grid & J channel in its final position in row without securing to grid, rod or adjacent fixture. - 1/16 Measure distance from fixture end cap to backside of molding surface where filler will rest. Trim filler as shown to length minus ~1/16 Lift end of fixture above height of tee and snap end filler into retaining spring so that it seats level with bottom of fixture. Carefully reinstall fixture in grid and final secure per installation instructions. TOOLLESS JOINING up the two housings by using the alignment splines & pins. Secure them together by using the Catch & Latch System on the top of the extrusion. Catch & Latch lignment Splines & Pins OPTIONL ENLIGHTED SENSOR: merlux and Enlighted have partnered to create building environments that are safer, and smarter, than ever before. t the heart of our partnership is Enlighted's Smart Sensor, the most advanced digital sensor available today. Integrated into merlux products, the sensor seamlessly collects and communicates dense data on building security, occupancy, performance, environmental conditions, ambient light levels, temperature, and energy consumption. This intelligence provides building managers with unprecedented guidance on cost savings and site-planning efficiencies. Enlighted Sensor (ENLS) is available with 0-10V driver only. Minimum run length is 4'. Enlighted power pack is provided with ENLS option. 4 FT OR 8 FT DIRECT RUNS Optional Enlighted Sensor 8 8 LIT /14/18 Page 7 of 12

8 GRUV 2.5" PTTERNS: Standard Patterns ll corners are standard 90, standard length legs. Use standard lengths: 4' min to 8' in 1 foot increments. Continuous runs must be the same length in pairs for closed configuration. 90 Custom Patterns Please provide drawings of your configuration. Made to Measure: +/- 1/8", consult factory. PC - custom pattern, please provide drawings and consult factory Gruv 2.5 Lens Mitered Lens PLL PLR Feed Feed Feed PLL - L Left, (2) straights + (1) 90 corner, leg right PLR - L Right, (2) straights + (1) 90 corner, leg left Provide overall lengths: ' & ' Nomenclature: --PLL --PLR PR - Closed Rectangle, (4) straight lengths + (4) 90 corners Provide overall lengths: ' & ' Nomenclature: --PR C C Feed Feed PU - Open U, (3) straight lengths + (2) 90 corners Provide overall lengths: ', ' & C' Nomenclature: --C-PU PZ - Open Z, (3) straight lengths + (2) 90 corners Provide overall lengths: ', ' & C' Nomenclature: --C-PZ Wall Ceiling WC - Wall to Ceiling - 90º joining bracket, 12" leg length standard Provide overall lengths: ' & ' Nomenclature: --PWC LIT /14/18 Page 8 of 12

9 FIXTURE DT: (Complete photometric data (.ies format) available upon request) MULTIPLYING FCTORS: (Multiplying Factor is based on 3500K V IES file on website) Wattage: 3W 4W 5W 6W 7W 8W 9W CCT: 2700K K K K-83 Factor: Factor: GRÜV 2.5 PERFORMNCE LENS 5W 3500K 4FT Total Watts: 20 Total Lumens: 1,972 Source: 128 White LEDs LTL# GRÜV 2.5 PERFORMNCE LENS 10W 3500K 4FT Total Watts: 40 Total Lumens: 3,662 Source: 128 White LEDs LTL# ZONL LUMEN SUMMRY Zone Lumens %Fixt Luminaire Efficacy = 99.5 lm/w COEFFICIENTS OF UTILIZTION RC 80 RW RCR Note: Values expressed as Lumens delivered to the task surface. ZONL LUMEN SUMMRY Zone Lumens %Fixt Luminaire Efficacy = 92.1 lm/w COEFFICIENTS OF UTILIZTION RC 80 RW RCR Note: Values expressed as Lumens delivered to the task surface. LIT /14/18 Page 9 of 12

10 FIXTURE DT: (Complete photometric data (.ies format) available upon request) MULTIPLYING FCTORS: (Multiplying Factor is based on 3500K V IES file on website) Wattage: 3W 4W 5W 6W 7W 8W 9W CCT: 2700K K K K-83 Factor: Factor: GRÜV 2.5 DESIGNER LENS 5W 3500K 4FT Total Watts: 20 Total Lumens: 1383 Source: 128 White LEDs LTL# GRÜV 2.5 DESIGNER LENS 10W 3500K 4FT Total Watts: 40 Total Lumens: 2567 Source: 128 White LEDs LTL# ZONL LUMEN SUMMRY Zone Lumens %Fixt ZONL LUMEN SUMMRY Zone Lumens %Fixt Luminaire Efficacy = 69.8 lm/w Luminaire Efficacy = 64.6 lm/w COEFFICIENTS OF UTILIZTION RC 80 RW RCR Note: Values expressed as Lumens delivered to the task surface. COEFFICIENTS OF UTILIZTION RC 80 RW RCR Note: Values expressed as Lumens delivered to the task surface. LIT /14/18 Page 10 of 12

11 DIMMING COMPTIILITY: merlux Gruv fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. merlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMTION ELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FCTORY V - DIMMING (Standard) Integrates into a variety of building management and daylighting controls 0-10V Wiring Diagram Notes: 120V or 277V* Dims down to 1% light output Requires interface to turn off power to driver Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Compatible Dimmers : Wall ox Lutron: Wattstopper: Leviton: Diva - DVSTV DF Renoir II Maestro - MS-Z101 Nova-T - NTSTV-DV Center System Lutron Grafixk Eye with GRX-TV1 Interface 0-10V Dimming Control Gray Purple White Green Driver 0-10V (-) 0-10V (+) Switched Hot V+ V- Red LUTRON HI-LUME DIMMING Integrates into Lutron EcoSystem building management Notes: 120V or 277V* Dims down to less than 5% light output May use 3-Wire or EcoSystem Control Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Compatible Dimmers : Wall ox (3-Wire Dimming) Lutron: Diva Maestro Nova-T Vareo Center System Lutron EcoSystem compatible controls HILUME--DH 3-Wire Wiring Diagram Cap unused ECOSYS wires 3-Wire Phase Dimming Control Purple Stripe Purple Orange White Green E1 E2 Driver Dimmed Hot Switched Hot HILUME--ECO, HILUME-H-ECO, HILUME-5-ECO EcoSystem Digital Control Wiring Diagram E2 E1 ECOSYS us EcoSystem Dimming Purple Stripe E1 Driver Control Purple E2 (Cap off Orange wire) Orange Dimmed Hot White Green Switched Hot V+ Red V- V+ V- Red Notes: * Driver is 277V dimmable with appropriate dimmer. ll provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. The absence of a dimmer from the lists above does not imply incompatibility. Please consult factory for compatibility inquiries. LIT /14/18 Page 11 of 12

12 DIMMING COMPTIILITY: merlux Gruv fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. merlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMTION ELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FCTORY --- LUTRON HILUME--LTE DIMMING Utilizes Standard incandescent dimmers that are in wide use in installations across the US. est for retrofit applications where TRIC dimmers are installed. Notes: 120V only Dims down to less than 1% light output (most cases) Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Must meet dimmer Minimum Load Requirements per dimming manufacturer Compatible Dimmers : Wall ox (Incandescent Style, Wattage as required) Lutron: Diva Maestro Nova-T Vareo Skylark Center System Lutron "GP" Panel Lutron Grafik Eye QS Lutron HILUME--LTE Wiring Diagram TRIC Dimming Control White Green Driver V+ V- Red DLI - DLI DIMMING 120V-277V Digital control protocol allows individual fixture control DLI Wiring Diagram Notes: 120V - 277V* Dims down to 0.1% light output in most cases DLI Dimming Control Purple Purple/WT DLI us Driver V+ Red Compatible Dimmers : Wall ox Leviton CD250 Controller White Green V- Center System Dynalite Fifth Light Notes: * Driver is 277V dimmable with appropriate dimmer. ll provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. The absence of a dimmer from the lists above does not imply incompatibility. Please consult factory for compatibility inquiries. LIT /14/18 Page 12 of 12