REPAIR BUILDING ENVELOPE

Size: px
Start display at page:

Download "REPAIR BUILDING ENVELOPE"

Transcription

1 NO. DESCRIPTION 0 REPAIR BUILDING ENVELOPE AT CCAC NORTH CAMPUS TEAM RADELET McCARTHY POLLETTA INCORPORATED ARCHITECTS AND INTERIOR DESIGNERS 00 FIRST & MARKET BUILDING 00 FIRST AVENUE PITTSBURGH, PENNSYLVANIA () - FA () - INDE OF DRAWINGS G00 COVER SHEET AD0 DEMOLITION PLAN A0 PLAN A0 S A0 S A0 DETAILS ABBREVIATIONS ADDN ADDITION AFF ABOVE FINISHED FLOOR A/C AIR CONDITIONER < ANGLE APPRO APPROIMATELY BOT BOTTOM BLKHD BULKHEAD CPT CARPET CLG CEILING CL CENTER LINE CER CERAMIC CLR CLEAR COL(S) COLUMN(S) CONC CONCRETE CMU CONCRETE MASONRY UNIT COND CONDITION CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CG CORNER GUA FURN GWB GC HTG HT HM HORIZ HC ID INSUL LT MFR MAS MO MTL MECH NIC NTS OC OPNG FURNISH GYPSUM WALL BOA GENERAL CONTRACTOR HEATING HEIGHT HOLLOW METAL HORIZONTAL HVAC CONTRACTOR INSIDE DIAMETER INSULATION LIGHT MANUFACTURER MASONRY MASONRY OPENING METAL MECHANICAL NOT IN CONTRACT NOT TO SCALE ON CENTER OPENING GENERAL NOTES. Do not scale Drawings.. Dimensions are to column centerline, face of finish, face of masonry, or face of foundation wall, unless noted otherwise.. Verify dimensions of existing conditions at the site. Report discrepancies to Architect before proceeding with work.. Pressure treat and fire retard wood used for blocking.. Return adjacent areas disturbed by construction to its original condition.. Patch walls and floor structure disturbed by demolition or penetrations for new work.. Retain and protect items designated for reuse within the project. Return items to Owner as indicated.. Review status of salvageable material with Owner prior to removal from the site.. Limits of project are shown for general reference only and do not establish precise boundaries of work for any trade that may be required to complete the project. 0. Firestop roof - ceiling penetrations and penetrations through rated partitions. DRAWING SYMBOLS A A ROOM NAME ROOM NAME ROOM NO. AREA A NEW DOOR NEW SMOKE HR. FIRE RATED HR. FIRE RATED ROOM NAME AND NUMBER SECTION INTERIOR KEY DOOR NUMBER TYPE KEYED NOTE EQUIPMENT / ACCESSORY TAG CASEWORK TAG WINDOW TYPE AIR SUPPLY DIFFUSER RETURN AIR GRILL FLUORESCENT LIGHT FITURE FLUORESCENT LIGHT FITURE LOCATION MAP 0 Perry Highway Pittsburgh, PA 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... CCT DEMO DET DIA CUBICLE CURTAIN TRACK DEMOLITION DETAIL DIAMETER OH OD PERIM P-LAM OPPOSITE HAND OUTSIDE DIAMETER PERIMETER PLASTIC LAMINATE A DETAIL INCANDESCENT / COMPACT FLUORESCENT (SEE LIGHTING SCHEDULE) EIT SIGN KEY PLAN DIM(S) DIMENSION(S) P PLATE DR DN DS DOOR DOWN DOWNSPOUT PLBG PC PT PLUMBING PLUMBING CONTRACTOR POINT T/ FLOOR ELEV. (+0'-0") DATUM SPRINKLER HEAD DWG(S) DRAWING(S) RLG RAILING DF EA DRINKING FOUNTAIN EACH RWC REINF RAINWATER CONDUCTOR REINFORCE COLUMN GRID LINE EC ELECTRICAL CONTRACTOR RESIL RESILIENT EWC ELECTRIC WATER COOLER REQD REQUIRED EQ EQUAL R RISER EQUIP EQUIPMENT DRAIN EH EHAUST RO ROUGH OPENING EIST ET FDC FE EISTING ETERIOR FIRE DEPARTMENT CONNECTION FIRE ETINGUISHER SPEC SST STL STRUCT SPECIFICATION STAINLESS STEEL STEEL STRUCTURAL FEC FIRE ETINGUISHER CABINET TLT TOILET FHC FIRE HOSE CABINET TOB TOP OF BEAM FP FIRE PULL TOM TOP OF MASONRY FPH FIRE PHONE T TREAD FOS FACE OF STUD TYP TYPICAL FIN FLR FD FINISH FLOOR FLOOR DRAIN UNO UNLESS NOTED OTHERWISE VERT VERTICAL W/ WITH COVER SHEET FDTN FOUNDATION WP WORKING POINT OWNER NUMBER NUMBER -NC-00e 0 0// G00

2 NO. DESCRIPTION 0 AND LIGHTNING PROTECTION COMPONENTS TO REMAIN THIS R-0 TEAM AIR HANDLING UNITS, CURBS, AND ASSOCIATED PIPING / EQUIPMENT TO REMAIN, EIST. ACCU- R-00 MECHANICAL PENETRATIONS AND ASSOCIATED CURBS / EQUIPMENT TO REMAIN, LIGHTING PROTECTION TO REMAIN AT SURFACE, EIST. ACCU- R-00A METAL DRIP EDGE AND LIGHTNING PROTECTION TO REMAIN AT PERIMETER EHAUST FANS, SKYLIGHTS, AND ASSOCIATED CURBS TO REMAIN, TYP EIST. ACCU- REMOVE / REINSTALL ACCESS LADDER AS REQUIRED FOR PARAPET MODIFICATIONS. PROVIDE TEMPORARY CONSTRUCTION / EMERGENCY ACCESS - PROTECT MEMBRANE WHERE LOCATED A0 A0 LIGHTING PROTECTION TO REMAIN AT SURFACE, SCALE: " = '-0" 0 FEET A0 Base Bid Area of Work REMOVE / REINSTALL ACCESS LADDER AS REQUIRED FOR PARAPET MODIFICATIONS. PROVIDE TEMPORARY CONSTRUCTION / EMERGENCY ACCESS - PROTECT MEMBRANE WHERE LOCATED O.A. INTAKE AND CURB TO REMAIN GRAVITY RELIEF VENT AND CURB TO REMAIN MAIN R-0 EIST. ACCU- PORTICO R-0 A0 R-0 SKYLIGHT FRAME AND GLAZING TO REMAIN EHAUST FAN AND CURB TO REMAIN, TYP LIGHTING PROTECTION TO REMAIN AT SURFACE, EIST. ACCU- SKYLIGHT FRAME AND GLAZING TO REMAIN GRAVITY RELIEF VENT AND CURB TO REMAIN 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... ACCESS DOOR WALKWAY MAT EIFS PARAPET, - REFER TO DEMOLITION DETAILS FOR ETENTS OF REMOVAL OVERFLOW SCUPPER, LOWER R-0 A0 EIST. ACCU- EIST. ACCU- R-0A OVERFLOW SCUPPER, AIR HANDLING UNITS TO REMAIN, METAL DRIP EDGE AND LIGHTNING PROTECTION TO REMAIN AT PERIMETER A0 A0 A0 GENERAL DEMOLITION NOTES. Dimensions indicated are for reference only. Field conditions shall be verified prior to construction.. Where portion of existing parapet to be removed, salvage lightning protection components for reinstallation / re-certification. Refer to A0 for additional information.. Protect existing roof membrane and components during duration of project. In areas requiring staging / scaffold point loads, coordinate type of solid protective material with Architect / roof manufacturer representative prior to commencing work.. Coordinate staging of materials and equipment w/ Owner. LIGHTING PROTECTION TO REMAIN AT SURFACE GYMNASIUM R-0. Remove perimeter sealant at door, window, louver openings and prepare adjacent EIFS surface to receive new sealant - refer to plan and elevations for locations related to Base Bid and Alternates.. Remove sealant between EIFS panel sections at all vertical joint locations - prepare EIFS surfaces to receive new sealant.. Remove / replace plywood backing at inside face of parapet where damaged from moisture infiltration prior to coping / flashing installation. Demolition Roof Plan A0 A0 LIGHTNING PROTECTION KEY: Existing Lightning Protection Cabling OWNER NUMBER -NC-00e Existing Lightning Protection Roof Penetration NUMBER 0 AD0 AD0 DEMOLITION PLAN /" = '-0" Notes: - Coordinate removal / reinstallation with certified Lightning Protection representative - Components and quantities to be determined as part of certification 0//

3 '-" '-0" '-" NO. DESCRIPTION 0 A0 '-" '-0" R-0 EIST. ACCU- A0 0'-" TEAM '-0" '-0" 0'-0" '-0" A0 EIST. ACCU- EIST. ACCU- A0 A0 A0 A0 R-0 A0 A0 R-00A A0 '-0" MAIN R-0 A0 R-00 A0 EIST. ACCU- EIST. ACCU- '-" '-" '-0" PORTICO R-0 A0 0'-" '-" 0'-" 0'-" SCALE: " = '-0" 0 FEET Base Bid Area of Work 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... A0 '-0" '-0" '-" '-" '-" '-" A0 A0 LOWER R-0 A0 A0 EIST. ACCU- EIST. ACCU- R-0A A0 '-" '-" A0 0 A0 GYMNASIUM R-0 '-" OWNER NUMBER -NC-00e Roof Plan A0 PLAN /" = '-0" '-" '-" '-0" '-0" '-" '-" '-" A0 '-" GENERAL CONSTRUCTION NOTES. Dimensions indicated are for reference only. Field conditions shall be verified prior to construction.. Reinstall and re-certify lightning protection system where removed. Provide replacement components where required if damaged or in condition that will prevent certification. CONSTRUCTION KEY NOTES. Re-seal perimeter of door, window, and louver openings - refer to elevations for extents related to Base Bid and Alternates.. Recoat vertical surfaces - refer to elevations for extents related to Base Bid and Alternates. NUMBER 0 0// A0

4 - REFER TO A0 FOR DETAILS EISTING CURTAIN WALL / SKYLIGHT SEALANT TO REMAIN NO. DESCRIPTION 0 HVAC BEYOND - REFER TO A0 FOR DETAILS RECOAT EIFS SURFACE - FINISH TO MATCH EISTING. REPLACE SEALANT AT VERTICAL JOINTS WITHIN BASE BID REPAIR ETENTS, ALL LOCATIONS. REFER TO /A0 BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL A0 RECOAT EIFS SURFACE - FINISH TO MATCH EISTING. REPLACE SEALANT AT VERTICAL JOINTS WITHIN BASE BID REPAIR ETENTS, ALL LOCATIONS. REFER TO 0/A0 BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL A0 HVAC BEYOND BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL TEAM ADD ALTERNATE NO : REMOVE / REPLACE CONSTRUCTION SEALANT AT ALL VERTICAL JOINTS BELOW BASE BID ETENTS. PREP EIFS SURFACES PRIOR TO APPLICATION OF NEW SEALANT - ALL VERTICAL JOINTS. APPLY NEW BACKER ROD AND SEALANT AS PER DETAIL EISTING CURTAIN WALL AND COLUMNS TO REMAIN A0 EAST /" = '-0" EISTING SKYLIGHT SEALANT TO REMAIN EISTING SKYLIGHT SEALANT TO REMAIN REFER TO /A0 FOR ATRIUM REFER TO /A0 FOR BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL A0 BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL SCALE: " = '-0" 0 FEET A0 SOUTH /" = '-0" EISTING CURTAIN WALL / SKYLIGHT SEALANT TO REMAIN A0 REFER TO /A0 FOR BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL A0 BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... A0 WEST /" = '-0" REFER TO /A0 FOR ATRIUM REFER TO /A0 FOR BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL BASE BID: EIFS REPAIR ETENTS ADD ALTERNATE NO. : FULL A0 CONSTRUCTION KEY NOTES. Add Alternate No. : Remove and replace perimeter sealants between EIFS panels and adjacent doors, windows, and mechanical penetrations below level of Base Bid work extents. Elevations. Provide Unit Cost for new gasketing at aluminum windows, doors, and window walls below level of Base Bid work extents. A0 NORTH /" = '-0" KEY: Extent of EIFS repair under Base Bid. Repair and recoat surface - color to match existing. OWNER NUMBER NUMBER -NC-00e 0 0// A0

5 REVISIONS DESCRIPTION A0 NO. 0 CONTINUOUS METAL COPING, - REFER TO A0 FOR DETAILS '-"+/- '-0"+/- TEAM GENERAL CONSTRUCTION NOTES CONSTRUCTION KEY NOTES. Dimensions indicated are for reference only. Field conditions shall be verified prior to construction.. Base Bid: Remove and replace perimeter sealants between EIFS panels and adjacent doors, windows, and mechanical penetrations.. Air terminals / lightning protection not shown this sheet - spacing and final locations to be determined by certified Lightning Protection installer and coordinated with Architect.. Provide Unit Cost for new gasketing at aluminum windows, doors, and window walls. KEY: Extent of EIFS repair under Base Bid. Repair and recoat surface - color to match existing. A0 SOUTH ATRIUM /" = '-0" REMOVE / REINSTALL LADDER AS A0 SCALE: " = '-0" '-"+/- FEET '-0"+/- 0 A0 NORTH ATRIUM /" = '-0" REMOVE / REINSTALL LADDER AS REQUIRED FOR INSTALLATION OF 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... A0 A0 '-"+/- '-"+/- A0 A0 A0 /" = '-0" A0 /" = '-0" /" = '-0" A0 Elevations '-"+/- '-"+/- A0 '-"+/- '-0"+/- '-0"+/- A0 A0 OWNER NUMBER -NC-00e NUMBER 0 A0 /" = '-0" A0 /" = '-0" A0 /" = '-0" A0 /" = '-0" 0// A0

6 NO. DESCRIPTION 0 TOP OF WALL BOA - MAINTAIN EISTING WALL CONSTRUCTION. PREP REMOVE PLYWOOD BACKING / GWB REMOVE EISTING MEMBRANE LAP EISTING PVC MEMBRANE, TOP OF WALL BOA - MAINTAIN EISTING WALL CONSTRUCTION. PREP REMOVE PLYWOOD BACKING / GWB REMOVE PORTION OF EIFS PARAPET FACE - MAINTAIN EISTING PLYWOOD BACKING AND WALL CONSTRUCTION. PREP TO RECEIVE FLASHING MEMBRANE REMOVE EISTING MEMBRANE LAP EISTING PVC MEMBRANE, TOP OF WALL BOA - MAINTAIN EISTING WALL CONSTRUCTION. PREP REMOVE PLYWOOD BACKING / GWB REMOVE EISTING MEMBRANE LAP EISTING PVC MEMBRANE, COUNTER- FLASHING TO REMAIN TOP OF MASONRY WALL - MAINTAIN EISTING WALL CONSTRUCTION. PREP REMOVE PORTION OF EIFS PARAPET FACE AT MASONRY WALL- PREP TO RECEIVE FLASHING MEMBRANE REMOVE EISTING MEMBRANE LAP EISTING PVC MEMBRANE, TOP OF MASONRY WALL - MAINTAIN EISTING WALL CONSTRUCTION. PREP REMOVE EISTING MEMBRANE LAP EISTING PVC MEMBRANE, TEAM A0 " = '-0" A0 " = '-0" A0 " = '-0" A0 " = '-0" A0 " = '-0" REPLACE PLYWOOD BACKING / GWB EISTING PVC MEMBRANE, A0 REPLACE PLYWOOD BACKING / GWB EISTING PVC MEMBRANE, A0 A0 REPLACE PLYWOOD BACKING / GWB EISTING PVC MEMBRANE, A0 EISTING PVC MEMBRANE, A0 A0 EISTING PVC MEMBRANE, A0 A0 " = '-0" A0 " = '-0" A0 " = '-0" A0 " = '-0" 0 A0 " = '-0" 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... V.I.F. " METAL CLEAT CONTINUOUS FLEECE BACKED MEMBRANE - LAP OVER BLOCKING FLASHING MEMBRANE FULLY ADHERED TO SUBSTRATE WITH BONDING ADHESIVE - LAP OVER BLOCKING PRESSURE TREATED WOOD BLOCKING AND DRIP EDGE EISTING MTL STUD WALL CONSTRUCTION TO REMAIN REMOVE FASTENERS AT EISTING TERMINATION BAR - LAP NEW FLASHING MEMBRANE OVER EISTING COUNTERFLASHING AND REATTACH TERMINATION BAR " MIN. ETENSION TO DRIP EDGE VERIFY HEIGHT IN FIELD UPON REMOVAL OF EISTING EIFS PARAPET EISTING MTL STUD WALL CONSTRUCTION TO REMAIN ETEND BONDING ADHESIVE / FLASHING MEMBRANE / FLEECE BACKED MEMBRANE DOWN FACE OF PARAPET REMOVE FASTENERS AT EISTING TERMINATION BAR - LAP NEW FLASHING MEMBRANE OVER EISTING COUNTERFLASHING AND REATTACH TERMINATION BAR EISTING WALL CONSTRUCTION TO REMAIN Details PROVIDE MANUFACTURER SPECIFIED ADHESIVE WHERE LAPPED AT COUNTERFLASHING CONTINUOUS SEALANT EISTING PVC MEMBRANE AND PROVIDE MANUFACTURER SPECIFIED ADHESIVE WHERE LAPPED AT COUNTERFLASHING CONTINUOUS SEALANT EISTING PVC MEMBRANE AND COUNTERFLASHING TO REMAIN BACKER ROD AND SEALANT PREPARE EDGES OF EISTING EIFS PANELS TO RECEIVE NEW SEALANT RECOAT EIFS PANELS (REFER TO BASE BID ETENTS ON S) NOTE: BACKER ROD AND SEALANT DETAIL SIMILAR FOR WORK RELATED TO ADD ALTERNATE NO. OWNER NUMBER NUMBER -NC-00e 0 0// A0 A0 DETAIL " = '-0" A0 FLASHING DETAIL " = '-0" A0 VERTICAL EIFS JOINT DETAIL " = '-0"