Project: Amity Plaza Project No.: Amity Plaza Community Room

Size: px
Start display at page:

Download "Project: Amity Plaza Project No.: Amity Plaza Community Room"

Transcription

1 D a t e: September 9, 2013 Addendum No: 02 Project: Amity Plaza Project No.: Amity Plaza Community Room Owner: Architect: ej architecture, pllc 5745 South Bannock Street 575 Union Boulevard Littleton, CO Suite 200 PH: Lakewood, CO PH: ADDENDUM No. 02: Response to questions The following addendum is issued to modify or interpret the Construction Documents dated July 31, Drawing changes have been clouded and labeled Delta 1 for clarification. ATTACHMENTS: Sheet A8.0 Specification Section Painting and Coating A. ANSWERS TO CONTRACTOR QUESTIONS 01. What is the paint scope? A: Please see attached sheet A8.0 for finish schedule. Also see attached section Painting and Coating for specification. END OF BID ADDENDUM No. 02 architect redefining the role 575 Union Boulevard, Suite 200 Lakewood, CO Tel:

2 3' - 0" 9' - 0" Room Name Floor Finish ROOM FINISH SCHEDULE Baseboards Walls Ceiling North East South West Material Finish Material Finish Material Finish Material Finish Material Finish Material Finish Notes (E) COMMUNITY ROOM (E) (E) (E) (N) PAINT (E) (N) PAINT 2 (E) (N) PAINT 2 (E) (N) PAINT 4 (E) KITCHEN (E) (E) --- (E) (N) PAINT 2 (E) (E) (E) (N) PAINT 2 (E) (N) PAINT 2 (E) (N) PAINT 4 (E) LOBBY/RECEPTION AREA (E) (E) --- (E) (N) PAINT* (E) (E) (E) (E) (E) (E) (E) (E) Paint and repair as needed for new service counter. Color to match existing. (E) MEN'S RESTROOM (E) (E) --- (E) (N) PAINT 1 (E) (N) PAINT (E) (N) PAINT 1 (E) (N) PAINT 1 (E) (N) PAINT 4 (E) WOMEN'S RESTROOM (E) (E) --- (E) (N) PAINT 1 (E) (N) PAINT (E) (N) PAINT 1 (E) (N) PAINT 1 (E) (N) PAINT 4 (N) COMMUNITY ROOM ADDITION (N) VP (N) RB --- (N) GYP (N) PAINT 2 (N) GYP (N) PAINT/WD (E) (N) PAINT 2 (N) GYP (N) PAINT 2 (N) GYP (N) PAINT 4 VP-VINYL PLANK FLOORING RB-RESILIENT BASE WD-WOOD 8' - 0" ACCESSIBLE EXTERIOR DOOR 8' - 0" T T T FOLDING DOOR WALL SYSTEM Copyright: This document is an instrument of services, and as such remains the property of the architect. Permission for use of this document is limited and can be extended only by agreement with ej architecture PLLC. NOTE: PAINT COLORS ARE TO BE DETERMINED TYPE D1 TYPE D2 1 4' - 0" 4' - 3" DOOR LEGEND 1/4" = 1'-0" DOOR SCHEDULE DOOR # DESCRIPTION OPERATION FIRE RATING WIDTH HEIGHT THICKNESS MATERIAL FINSIH FRAME MATERIAL HARDWARE SET D1 EXIT/EGRESS DOOR SWING 20 min 3' - 0" 8' - 0" 2" STEEL HC PAINT STEEL (none) D2 Monumental Thermally Broken Folding FOLDING NR 9' - 0" 8' - 0" 1 5/8" ALUMINUM F.F. ALUMINUM (none) System Door Hardware Set HW SET DESCRIPTION DOOR HARDWARE SETS SCHEDULE 1 EXIT/EGRESS DOOR Yes Yes Yes Yes Yes Yes Yes Yes PASSAGE SET PRIVACY SET KEYED LOCK SET ELECTRINI LOCK SETt SECURITY HINGE DOOR CLOSER PANIC BAR SPRING HINGES SMOKE SEAL WEATHER SEAL 3' - 10" 3' - 0" 2' - 0" THRESHOLD 2' - 0" ELECTRIC OPENER COMMUNITY ROOM AMITY PLAZA 2' - 0" 2' - 0" ADA HARDWARE SIDE BOLTS DOOR VIEWER CANE BOLTS Barrel Gate Hinge 200 W. STERNE PARKWAY LITTLETON CO DRW CHK 9' - 0" 9' - 0" VARIES 9' - 0" REVISIONS NO. DESCRIPTION DATE 1 BID ADDENDUM WINDOW: A WINDOW: B WINDOW: C WINDOW: D WINDOW LEGEND 1/4" = 1'-0" ISSUE RECORD WINDOW SCHEDULE TYPE MARK HEIGHT WIDTH OPERATION SILL HEIGHT WINDOW MATERIAL A 2' - 0" 4' - 0" FIXED 9' - 0" ALUMINUM B 2' - 0" 4' - 3" FIXED 9' - 0" ALUMINUM C 2' - 0" 3' - 10" AWNING ALUMINUM D 2' - 0" 3' - 0" FIXED 9' - 0" ALUMINUM NO. DESCRIPTION DATE 1 BID SET PERMIT SET SHEET CONTENTS.: WINDOW, DOOR AND WALL LEGENDS AND SCHEDULES 16" BRICK 16" TYP. 3 COAT STUCCO 1" AIR GAP TYP R-7.5 CONT INSULATION RIGID INSULATION 5/8" GYP BOARD 2 X 6 METAL STUD 5/8" GYP BOARD WALL TYPE 2 DENSGLASS R-13 BATT INSULATION 2 X 6 METAL STUD 5/8" GYP BOARD WALL TYPE 1 8" X 16" CMU 1/2" METAL FURRING 5/8" GYP BOARD PROJ. NUMBER.: WALL TYPE 3 DATE.: AUGUST 23, 2013 DRAWING NUMBER.: WALL TYPES 1 1/2" = 1'-0" A8.0

3 Amity Plaza SECTION PAINTING AND COATING PART 1 GENERAL 1.01 SECTION INCLUDES A. Surface preparation. B. Field application of paints. C. Scope: Finish all interior and exterior surfaces exposed to view, unless fully factory-finished and unless otherwise indicated, including the following: 1. Both sides and edges of plywood backboards for electrical and telecom equipment before installing equipment. 2. Exposed surfaces of steel lintels and ledge angles. 3. Prime surfaces to receive wall coverings. 4. Mechanical and Electrical: a. In finished areas, paint all insulated and exposed pipes, conduit, boxes, insulated and exposed ducts, hangers, brackets, collars and supports, mechanical equipment, and electrical equipment, unless otherwise indicated. D. Do Not Paint or Finish the Following Items: 1. Items fully factory-finished unless specifically so indicated; materials and products having factory-applied primers are not considered factory finished. 2. Items indicated to receive other finishes. 3. Items indicated to remain unfinished. 4. Fire rating labels, equipment serial number and capacity labels, and operating parts of equipment. 5. Non-metallic roofing and flashing. 6. Stainless steel, anodized aluminum, bronze, terne, and lead items. 7. Marble, granite, slate, and other natural stones. 8. Floors, unless specifically so indicated. 9. Ceramic and other tiles. 10. Brick, architectural concrete, cast stone, integrally colored plaster and stucco. 11. Glass. 12. Concrete masonry in utility, mechanical, and electrical spaces. 13. Acoustical materials, unless specifically so indicated. 14. Concealed pipes, ducts, and conduits DEFINITIONS A. Conform to ASTM D16 for interpretation of terms used in this section REFERENCE STANDARDS A. 40 CFR 59, Subpart D - National Volatile Organic Compound Emission Standards for Architectural Coatings; U.S. Environmental Protection Agency; current edition. B. ASTM D16 - Standard Terminology for Paint, Related Coatings, Materials, and Applications; SUBMITTALS A. See Section Administrative Requirements, for submittal procedures. B. Product Data: Provide complete list of all products to be used, with the following information for each: / Amity Plaza PAINTING AND COATING

4 1. Manufacturer's name, product name and/or catalog number, and general product category (e.g. "alkyd enamel"). 2. MPI product number (e.g. MPI #47). 3. Cross-reference to specified paint system(s) product is to be used in; include description of each system. C. Samples: Submit three paper "drop" samples, 8-1/2 by 11 inches in size, illustrating range of colors available for each finishing product specified. 1. Where sheen is specified, submit samples in only that sheen. 2. Where sheen is not specified, discuss sheen options with Architect before preparing samples, to eliminate sheens definitely not required. D. Maintenance Materials: Furnish the following for 's use in maintenance of project. 1. See Section Product Requirements, for additional provisions. 2. Extra Paint and Coatings: 1 gallon of each color; store where directed. 3. Label each container with color in addition to the manufacturer's label QUALITY ASSURANCE A. Manufacturer Qualifications: Company specializing in manufacturing the products specified, with minimum three years documented experience DELIVERY, STORAGE, AND HANDLING A. Deliver products to site in sealed and labeled containers; inspect to verify acceptability. B. Container Label: Include manufacturer's name, type of paint, brand name, lot number, brand code, coverage, surface preparation, drying time, cleanup requirements, color designation, and instructions for mixing and reducing. C. Paint Materials: Store at minimum ambient temperature of 45 degrees F and a maximum of 90 degrees F, in ventilated area, and as required by manufacturer's instructions FIELD CONDITIONS A. Do not apply materials when surface and ambient temperatures are outside the temperature ranges required by the paint product manufacturer. B. Follow manufacturer's recommended procedures for producing best results, including testing of substrates, moisture in substrates, and humidity and temperature limitations. C. Do not apply exterior coatings during rain or snow, or when relative humidity is outside the humidity ranges required by the paint product manufacturer. D. Provide lighting level of 80 ft candles measured mid-height at substrate surface. PART 2 PRODUCTS 2.01 MANUFACTURERS Amity Plaza A. Provide all paint and coating products used in any individual system from the same manufacturer; no exceptions. B. Paints: 1. Comex Group (Color Wheel, Frazee, General Paint, Kwal, or Parker): 2. Duron, Inc: 3. Glidden Professional: 4. Benjamin Moore & Co: / Amity Plaza PAINTING AND COATING

5 5. PPG Architectural Finishes, Inc: 6. Pratt & Lambert Paints: 7. Sherwin-Williams Company: C. Primer Sealers: Same manufacturer as top coats. D. Substitutions: See Section Product Requirements PAINTS AND COATINGS - GENERAL A. Paints and Coatings: Ready mixed, unless intended to be a field-catalyzed coating. 1. Provide paints and coatings of a soft paste consistency, capable of being readily and uniformly dispersed to a homogeneous coating, with good flow and brushing properties, and capable of drying or curing free of streaks or sags. 2. Supply each coating material in quantity required to complete entire project's work from a single production run. 3. Do not reduce, thin, or dilute coatings or add materials to coatings unless such procedure is specifically described in manufacturer's product instructions. B. Primers: Where the manufacturer offers options on primers for a particular substrate, use primer categorized as "best" by the manufacturer. C. Volatile Organic Compound (VOC) Content: 1. Provide coatings that comply with the most stringent requirements specified in the following: a. 40 CFR 59, Subpart D--National Volatile Organic Compound Emission Standards for Architectural Coatings. 2. Determination of VOC Content: Testing and calculation in accordance with 40 CFR 59, Subpart D (EPA Method 24), exclusive of colorants added to a tint base and water added at project site; or other method acceptable to authorities having jurisdiction. D. Colors: To be selected from manufacturer's full range of available colors. 1. Selection to be made by Architect after award of contract. 2. Extend colors to surface edges; colors may change at any edge as directed by Architect. 3. In finished areas, finish pipes, ducts, conduit, and equipment the same color as the wall/ceiling they are mounted on/under PAINT SYSTEMS - EXTERIOR A. Paint MgE-OP-3L - Galvanized Metals, Latex, 3 Coat: 1. One coat galvanize primer. 2. Gloss: Two coats of latex enamel;. 3. Semi-gloss: Two coats of latex enamel; PAINT SYSTEMS - INTERIOR Amity Plaza A. Paint I-OP - All Interior Surfaces Indicated to be Painted, Unless Otherwise Indicated: Including gypsum board, concrete, wood, plaster, uncoated steel, shop primed steel, galvanized steel, and aluminum. 1. Two top coats and one coat primer. 2. Flat: MPI gloss level 1; use this sheen for ceilings and other overhead surfaces. 3. Eggshell: MPI gloss level 3; use this sheen at all locations. 4. Satin: MPI gloss level 4; use this sheen for items subject to frequent touching by occupants, including door frames and railings. 5. Semi-Gloss: MPI gloss level 5; use this sheen at bathrooms. 6. Primer(s): As follows unless other primer is required or recommended by manufacturer of top coats: a. Gypsum Board: MPI #50, Interior Latex Primer Sealer. b. Concrete: MPI #3, Alkali Resistant Water Based Primer / Amity Plaza PAINTING AND COATING

6 c. Plaster: MPI #50, Interior Latex Primer Sealer. d. Wood: MPI #39, Latex Primer for Interior Wood. e. Wood: MPI #45, Interior Alkyd Primer Sealer. f. Steel, Uncoated: MPI #79, Anti-Corrosive Alkyd Primer for Metal. g. Steel, Uncoated: MPI #107, Rust-Inhibitive Water Based Primer. h. Steel -- Shop Primer: MPI #76, Quick Dry Alkyd Primer for Metal. i. Galvanized Steel: MPI #134, Water Based Galvanized Primer. j. Galvanized Steel: Cementious primer. k. Aluminum: MPI #95, Quick Dry Primer for Aluminum. B. Paint I-OP-MD-DT - Medium Duty Door/Trim: For surfaces subject to frequent contact by occupants, including metals and wood: 1. Two top coats and one coat primer. 2. Semi-Gloss: MPI gloss level 5; use this sheen at all locations. 3. Primer(s): As recommended by manufacturer of top coats ACCESSORY MATERIALS A. Accessory Materials: Provide all primers, sealers, cleaning agents, cleaning cloths, sanding materials, and clean-up materials required to achieve the finishes specified whether specifically indicated or not; commercial quality. B. Patching Material: Latex filler. C. Fastener Head Cover Material: Latex filler. PART 3 EXECUTION 3.01 EXAMINATION A. Verify that surfaces are ready to receive work as instructed by the product manufacturer. B. Examine surfaces scheduled to be finished prior to commencement of work. Report any condition that may potentially affect proper application. C. Test shop-applied primer for compatibility with subsequent cover materials. D. Measure moisture content of surfaces using an electronic moisture meter. Do not apply finishes unless moisture content of surfaces are below the following maximums: 1. Gypsum Wallboard: 12 percent. 2. Plaster and Stucco: 12 percent. 3. Masonry, Concrete, and Concrete Unit Masonry: 12 percent PREPARATION Amity Plaza A. Clean surfaces thoroughly and correct defects prior to coating application. B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. C. Remove or mask surface appurtenances, including electrical plates, hardware, light fixture trim, escutcheons, and fittings, prior to preparing surfaces or finishing. D. Seal surfaces that might cause bleed through or staining of topcoat. E. Remove mildew from impervious surfaces by scrubbing with solution of tetra-sodium phosphate and bleach. Rinse with clean water and allow surface to dry. F. Concrete and Unit Masonry Surfaces to be Painted: Remove dirt, loose mortar, scale, salt or alkali powder, and other foreign matter. Remove oil and grease with a solution of tri-sodium phosphate; rinse well and allow to dry. Remove stains caused by weathering of corroding / Amity Plaza PAINTING AND COATING

7 metals with a solution of sodium metasilicate after thoroughly wetting with water. Allow to dry. G. Gypsum Board Surfaces to be Painted: Fill minor defects with filler compound. Spot prime defects after repair. H. Plaster Surfaces to be Painted: Fill hairline cracks, small holes, and imperfections with latex patching plaster. Make smooth and flush with adjacent surfaces. Wash and neutralize high alkali surfaces. I. Aluminum Surfaces to be Painted: Remove surface contamination by steam or high pressure water. Remove oxidation with acid etch and solvent washing. Apply etching primer immediately following cleaning. J. Galvanized Surfaces to be Painted: Remove surface contamination and oils and wash with solvent. Apply coat of etching primer. K. Corroded Steel and Iron Surfaces to be Painted: Prepare using at least SSPC-PC 2 (hand tool cleaning) or SSPC-SP 3 (power tool cleaning) followed by SSPC-SP 1 (solvent cleaning). L. Uncorroded Uncoated Steel and Iron Surfaces to be Painted: Remove grease, mill scale, weld splatter, dirt, and rust. Where heavy coatings of scale are evident, remove by hand or power tool wire brushing or sandblasting; clean by washing with solvent. Apply a treatment of phosphoric acid solution, ensuring weld joints, bolts, and nuts are similarly cleaned. Prime paint entire surface; spot prime after repairs. M. Shop-Primed Steel Surfaces to be Finish Painted: Sand and scrape to remove loose primer and rust. Feather edges to make touch-up patches inconspicuous. Clean surfaces with solvent. Prime bare steel surfaces. Re-prime entire shop-primed item APPLICATION A. Remove unfinished louvers, grilles, covers, and access panels on mechanical and electrical components and paint separately. B. Apply products in accordance with manufacturer's instructions. C. Do not apply finishes to surfaces that are not dry. Allow applied coats to dry before next coat is applied. D. Apply each coat to uniform appearance. E. Sand wood and metal surfaces lightly between coats to achieve required finish. F. Vacuum clean surfaces of loose particles. Use tack cloth to remove dust and particles just prior to applying next coat. G. Reinstall electrical cover plates, hardware, light fixture trim, escutcheons, and fittings removed prior to finishing FIELD QUALITY CONTROL A. See Section Quality Requirements, for general requirements for field inspection CLEANING A. Collect waste material that could constitute a fire hazard, place in closed metal containers, and remove daily from site PROTECTION Amity Plaza A. Protect finished coatings until completion of project. B. Touch-up damaged coatings after Substantial Completion / Amity Plaza PAINTING AND COATING

8 Amity Plaza END OF SECTION / Amity Plaza PAINTING AND COATING