ESD-603D. Miami-Dade Qualified Drainable Blade Louver. Application and Design. Standard Construction. Options (at additional cost)

Size: px
Start display at page:

Download "ESD-603D. Miami-Dade Qualified Drainable Blade Louver. Application and Design. Standard Construction. Options (at additional cost)"

Transcription

1 Miami-Dade Qualified Drainable Blade Louver Florida Product Approval No: FL Application and Design is an extruded aluminum drainable blade louver designed to protect air intake and exhaust openings in building exteriors specifically for applications requiring extremely high structural design loadings. Design characteristics meet the performance requirements established by the Florida Building Code and Miami-Dade County. Tested in accordance with and passes TAS 201 (Large Missile Impact), TAS 202 (Uniform Static Air Pressure), TAS 203 (Cyclic Wind Loading) and TAS 100A (Wind-Driven Rain) with optiononal HCD-240 damper. may be installed in locations where the space behind the louver is designed to accept water penetration and houses water resistant/ water proof equipment, components or supplies. Qualified for installation within masonry/concrete or structural steel framed building conditions. Standard Construction Frame Heavy gauge extruded 6063T5 aluminum, 6 in. x in. nominal wall thickness Blades Drainable design, heavy gauge extruded aluminum, in. nominal wall thickness, positioned at 37º and 45º angles on approximately 6 in. centers Construction....Welded and mechanically fastened Birdscreen /4 in. x fl attened expanded aluminum in removable frame, inside mount (rear) Finish Mill Anchor Plates...Factory attached, heavy gauge steel, Permatector fi nish Structural Supports......Heavy gauge steel, Permatector fi nish Minimum Rough Opening Size...12 in. W x 15 in. H Maximum Rough Opening Size...Unlimited in. W x 120 in. H Maximum Single Section Rough Opening Size...60 ½ in. W x 120 in. H Options (at additional cost) A variety of bird and insect screens Extended sill A variety of architectural finishes including: Clear anodize Integral color anodize Baked enamel Kynar Optional factory attached HCD-240 damper May be installed in locations up to 33 ft. above grade where the space behind the louver is not designed to accept water penetration and houses non-water resistant/water proof equipment, components or supplies. Vertical blade axis Parallel blade action Galvanized steel linkage Silicone blade seals Stainless steel compression jamb seals Plated steel axles Stainless steel sleeve bearings Viton O-ring shaft seals Manual quadrant actuator (in airstream) Mill fi nish only Minimum Rough Opening Size...12 in. W x 15 in. H Maximum Rough Opening Size...Unlimitedin. W x 120 in. H Maximum Single Section Rough Opening Size...60½ in. W x 120 in. H

2 PERFORMANCE DATA Free Area Chart R.O Rough Opening Width in Inches Height Inches Florida Product Approval No.: FL Greenheck Fan Corportation certifies that the ESD- 603D louvers shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. Airflow Resistance (Standard Air lb/ft 3 ) Static Pressure Drop Pa in. wg Test Size 48 in. x 48 in. Standard Air lb/ft 3 Intake Exhaust Water Penetration (Standard Air lb./ft.3) Test size 48 in. x 48 in. Test duration of 15 min. Water Penetration per Unit Free Area ml/m oz/ft Test Size 48 in. x 48 in. Test Period 15 minutes Standard Air lb/ft ft/min m/s Free Air Velocity Model resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size. See louver selection information. 0 m/s: 0.00 ft/min: Free Area Velocity The AMCA Water Penetration Test provides a method for comparing various louver models and designs as to their efficiency in resisting the penetration of rainfall under specific laboratory test conditions. The beginning point of water penetration is defined as that velocity where the water penetration curve projects through.01 oz. of water (penetration) per sq. ft. of louver free area. *The beginning point of water penetration for Model ESD- 603D is 1027 fpm free area velocity. These perfor mance ratings do not guarantee a louver to be weather proof or stormproof and should be used in combination with other factors including good engineering judgement in selecting louvers.

3 INSTALLATION DETAILS Florida Product Approval No.: FL Model is a Miami-Dade Qualified and Florida Product Approved louver and must be installed in accordance with the installation instructions shown herein. Model is qualified for installation within concrete/masonry and structural steel building conditions. Model is structurally calculated to withstand positive and negative wind-loads up to 138 PSF. The maximum single section rough opening width is 60½ in. The maximum rough opening height is 120 in. While the maximum rough opening height is limited to 120 in., the rough opening width may be unlimited as multiple sections may be installed side by side in accordance with installation instructions. Minimum Rough Opening Size 12 in. W x 15 in. H Maximum Single Section Rough Opening Size 60½ in. W x 120 in. H

4 PRODUCT DETAILS Florida Product Approval No.: FL4826.1

5 PRODUCT DETAILS Florida Product Approval No.: FL4826.1

6 OPTION DRAWINGS Florida Product Approval No.: FL4826.1

7 INSTALLATION DETAILS with HCD-240 Florida Product Approval No.: FL Miami-Dade NOA No.: Maximum Size and Installation Information Model /HCD-240 is a Miami-Dade Qualified and Florida Product Approved louver and must be installed in accordance with the installation instructions shown herein. Model /HCD-240 is qualified for installation within concrete/masonry, structural steel building conditions. Model /HCD-240 is structurally calculated to withstand positive and negative wind-loads up to 138 PSF. The maximum single section rough opening width is 60½ in. The maximum rough opening height is 120 in. While the maximum rough opening height is limited to 120 in., the rough opening width may be unlimited as multiple sections may be installed side by side in accordance with installation instructions. Minimum Rough Opening Size 12 in. W x 15 in. H Maximum Single Section Rough Opening Size 60½ in. W x 120 in. H

8 PRODUCT DETAILS with HCD-240 Florida Product Approval No.: FL Miami-Dade NOA No.:

9 PRODUCT DETAILS with HCD-240 Florida Product Approval No.: FL Miami-Dade NOA No.:

10 OPTION DRAWINGS with HCD-240 Florida Product Approval No.: FL Miami-Dade NOA No.: FINISHES Finish Type Description/Application Color Selection Standard Warranty (Aluminum) 2-coat 70% KYNAR 500 /HYLAR 5000 AAMA 2605 Dry film thickness 1.2 mil. (AKA: Duranar, Fluoropon, Trinar, Flouropolymer, Polyvinylidene Fluoride, PVDF2) Best. The premier finish for extruded aluminum. Tough, long-lasting coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Standard Colors: Any of the 24 standard colors shown can be furnished in 70% or 50% KYNAR 500 /HYLAR 5000 or Baked Enamel. 10 Years (Consult Greenheck for availability of extended warranty) 2-coat 50% KYNAR 500 /HYLAR 5000 AAMA 2604 Dry film thickness 1.2 mil. (AKA: Acroflur, Acrynar ) Baked Enamel AAMA 2603 Dry film thickness 0.8 mil. (AKA: Acrabond Plus, Duracron ) Better. Tough, long-lasting coating has excellent color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Good. Provides good adhesion and resistance to weathering, corrosion and chemical stain. 2-Coat Mica: Greenheck offers 9 standard 2-coat Mica colors. Other colors are available. Consult Greenheck for possible extra cost when selecting non-standard colors or special finishes. 5 Years 1 Year Integral Color Anodize AA-M10C22A42 (>0.7 mil) Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil) Clear Anodize 204 R-1 AA-M10C22A31 ( mil) Industrial coatings Mill Two-step anodizing is produced by following the normal anodizing step with a second, colorfast process. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Light, Medium or Dark Bronze; Champagne; Black Clear Clear Greenheck offers a number of industrial coatings such as Hi-Pro Polyester, Epoxy, and Permatector. Consult a Greenheck Product Specialist for complete color and application information. Materials may be supplied in natural aluminum or galvanized steel finish when normal weathering is acceptable and there is no concern for color or color change. 5 years 5 years 1 Year Consult Greenheck Finishes meet or exceed AAMA 2605, AAMA 2604, and AAMA 2603 requirements. Please consult for complete information on standard and extended paint warranties. Paint finish warranties are not applicable to steel products. n/a July 2010 Rev. 1 Copyright 2010 Greenheck Fan Corporation Greenheck Fan Corporation reserves the right to make product changes without notice.