REVISION CHANGES: REV. NO. REV. DATE

Size: px
Start display at page:

Download "REVISION CHANGES: REV. NO. REV. DATE"

Transcription

1 OWNER: TAYLOR MORRISON HOMES 24 HOUR CONTACT RANDY COLLINS Cell Office STRUCTURAL ENGINEER PEACH STATE BUILDING CONSULTANTS, INC. P.O.BOX 2506, SUWANEE, GA CONTACT: MICHAEL D. MUNTEAN, P.E ARCHITECTURAL INDEX SHEET NAME PAGE A0.0 A.0.1 A.1.1 A.2.1 A.3.1 A.4.0 A.4.1 A.5.0 S1.0 COVER SHEET SLAB FOUNDATION PLAN TERRACE PLAN 1ST. FLOOR PLAN 2ND. FLOOR PLAN FRONT ELEVATION FRONT ELEVATION REAR ELEVATION AND RO PLAN TYPICAL 2HR. FIREWALL DETAIL TYPICAL DECK DETAIL C COPYRIGHT 2016 TAYLOR MORRISON --- THESE DRAWINGS AND ITS REPRODUCTIONS ARE THE PROPERTY TAYLOR MORRISON AND MAY NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE WRITTEN PERMISSION E.0.0 ELECTRICAL PLAN SHEET CONTENTS GENERAL NOTES, AND FASTENER SCHEDULE SLAB FOUNDATION PLAN- LOTS 20-22\ FOOTING DETAILS TERRACE PLAN - LOTS ST. FLOOR PLAN - LOTS ND. FLOOR PLAN - LOTS BUILDING ELEVATION - LOTS UNIT ELEVATIONS SHAFT WALL DETAIL - U336 WALL TERRACE, 1ST. AND 2ND. FLOOR PLANS\ LEGEND PROJECT DESCRIPTION: 3 STORY TOWNHOMES TYPE CONSTRUCTION: TYPE V-B RESIDENTIAL COVENTIONAL LIGHT-FRAME WOOD CONSTRUCTION - NON-SPRINKLERED OCCUPANCY CLASSIFICATION: SINGLE FAMILY HOME -ATTACHED

2 C COPYRIGHT 2016 TAYLOR MORRISON --- THESE DRAWINGS AND ITS REPRODUCTIONS ARE THE PROPERTY TAYLOR MORRISON AND MAY NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE WRITTEN PERMISSION

3 C COPYRIGHT 2016 TAYLOR MORRISON --- THESE DRAWINGS AND ITS REPRODUCTIONS ARE THE PROPERTY TAYLOR MORRISON AND MAY NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE WRITTEN PERMISSION

4 C COPYRIGHT 2016 TAYLOR MORRISON --- THESE DRAWINGS AND ITS REPRODUCTIONS ARE THE PROPERTY TAYLOR MORRISON AND MAY NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE WRITTEN PERMISSION

5 C COPYRIGHT 2016 TAYLOR MORRISON --- THESE DRAWINGS AND ITS REPRODUCTIONS ARE THE PROPERTY TAYLOR MORRISON AND MAY NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE WRITTEN PERMISSION

6 7'-6" 10'-8" 3: SLOPE ASPHALT SHINGLES 7'-6" 6: SLOPE ASPHALT SHINGLES 6: SLOPE : SLOPE ASPHALT SHINGLES 10 6: SLOPE 18X24 RECT.VENT 6: SLOPE ASPHALT SHINGLES 6" FASCIA BRD., TYP. DECORATIVE 24" O.C.- FYPON 8xx3 OR SIMILAR, TYP. 8" FREIZE W/ 4" CROWN, TYP. 2030/3030/2030 FX. WINDOW, TYP. 4'-6" 3'-4" 2440 WINDOW IN DORMER, TYP. 5'-0" 3'-4" 6' " 4'-0" 8 BRICK VENEER, TYP. 8 4'-0" PLATE HDR. HGT. C COPYRIGHT 2016 TAYLOR MORRISON --- THESE DRAWINGS AND ITS REPRODUCTIONS ARE THE PROPERTY TAYLOR MORRISON AND MAY NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE WRITTEN PERMISSION " PLANK SHUTTERS, TYP. BRICK JACK ARCH W, STONE KEY, TYP. METAL EYEBROW, TYP. WOOD BRACKET- BKT24X30X4, TYP. 11'-8" BRICK STEPS 5'-2" BRICK VENEER, TYP. 5'-2" METAL RO 4: WROUGHT IRON RAIL BRICK VENEER, TYP. STONE PEDIMENT, TYP. WOOD BRACKET- BKT24X30X4, TYP. BRICK STEPS 5'-2" BRICK VENEER, TYP. 4: METAL RO WOOD BRACKET- BKT24X30X4, TYP. METAL RO " BRICK VENEER, TYP. PLATE 7'-11" 6'-11" 2ND FLR. HDR. HGT. 1ST FLR. PLATE HDR. HGT. TERRACE 6'-11" 9'-1" 1'-4 3/4" 10'-1" 1'-4 3/4" 8'-1"

7 C COPYRIGHT 2016 TAYLOR MORRISON --- THESE DRAWINGS AND ITS REPRODUCTIONS ARE THE PROPERTY TAYLOR MORRISON AND MAY NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE WRITTEN PERMISSION 1'-4" O.H. AT FRONT

8

9 guard decking beam joist hanger existing house wall joist hanger ledger board fasteners existing house floor construction post beyond joist span joist ledger board FIGURE 3: JOIST SPAN - JOISTS ATTACHED TO SIDE BEAM guard post attachment ledger board attachment to existing house rim joist beam joists post-to-beam connection joist-to-beam connection post GENERAL REQUIREMENTS 1. Lumber shall be naturally durable wood or shall be southern pine, grade #2 or better that is pressurepreservative-treated in accordance with AWPA U1 for the species, product, preservative and end use. Field cut ends, notches and drilled holes of preservative treated wood shall be treated in the field in accordance with AWPA M4. Preservative- treated lumber in contact with the ground shall be rated as ground-contact. Please note: not all treated lumber is rated for ground contact. 2. Wood-plastic composites are composed of bound wood and plastic fibers creating material that can be used as decking and guard elements as permitted herein. Permissible wood-plastic composites must bear a label indicating its performance criteria and compliance with ASTM D Nails shall be ring-shanked or annular grooved. 4. Screws and nails shall be hot-dipped galvanized, stainless steel or approved for use with pressure hold-down anchor, typical treated lumber. 5. Hardware, e.g., joist hangers, cast-in-place post anchors, mechanical fasteners, shall be galvanized 05/05/2016 guard post with 1.85 oz/sf of zinc (G-185 coating) or shall be stainless steel. Use products such as Zmax from Simpson Strong-Tie or Triple Zinc and Gold Coat from USP. 6. Electrical receptacles for decks shall comply with the currently approved edition of the National Electrical Code. 7. Lighting for decks and exterior stairs shall comply with IRC Stairway Illumination. SECTION blocking GUARD POST -TO-OUTSIDE JOIST DETAIL

10 C COPYRIGHT 2016 TAYLOR MORRISON --- THESE DRAWINGS AND ITS REPRODUCTIONS ARE THE PROPERTY TAYLOR MORRISON AND MAY NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE WRITTEN PERMISSION