FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION. Florida Department of Business and Professional Regulation - Residential Performance Method

Size: px
Start display at page:

Download "FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION. Florida Department of Business and Professional Regulation - Residential Performance Method"

Transcription

1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Merryplace Homes Type II Builder Name: Merryplace Homes Street: 45 Lilac Ct Permit Office: West Palm Beach City, State, Zip: West Palm Beach, FL, Permit Number: Owner: West Palm Beach Housing Auth. Jurisdiction: Design Location: FL, West Palm Beach County:: palm Beach (Florida Climate Zone 2 ). New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade () Conditioned floor area below grade () 0 New (From Plans) Single-family No Windows(250.0 sqft.) a. U-Factor: Description Sgl, U= b. U-Factor: SHGC=0.53 c. U-Factor: d. U-Factor: Weighted Average Overhang Depth: 5.2 ft. Weighted Average Floor Types (523.0 sqft.) a. Slab-On-Grade Edge b. c. Glass/Floor : R= R= R= Total Proposed Modified Loads: Total Baseline Loads: 9. Wall Types (698. sqft.) a. Concrete Block - Int Insul, Exterior R= b. Frame - Wood, Adjacent R= c. R= d. R= 0. Ceiling Types (523.0 sqft.) a. Under Attic (Vented) R= b. R= c. R=. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R Cooling systems a. Central Unit 3. Heating systems a. Electric Strip Heat kbtu/hr Efficiency 35.0 SEER:6.00 kbtu/hr Efficiency 34.0 COP: Hot water systems a. Electric Cap: 40 gallons EF: b. Conservation features 5. Credits Pstat PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section Florida Statutes. BUILDING OFFICIAL: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R Compliance requires an Air Barrier and Inspection Checklist in accordance with R and an envelope leakage test report in accordance with R /5/207 5:7 PM EnergyGauge USA - FlaRes204 Section R Compliant Software Page of 5

2 Title: Merryplace Homes Type II Building Type: User Owner: West Palm Beach Housing A # of Units: Builder Name: Merryplace Homes Permit Office: West Palm Beach Jurisdiction: Family Type: Single-family New/Existing: New (From Plans) Comment: PROJECT Bedrooms: 3 Conditioned : 523 Total Stories: Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 45 Lilac Ct palm Beach West Palm Beach, FL, CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, West Palm Beach FL_WEST_PALM_BEAC 2 Number Name Volume Block BLOCKS SPACES Medium Number Name Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated System Yes 4 3 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Tile Wood Carpet Slab-On-Grade Edge Insulatio System 82 ft ROOF Roof Gable Roof Solar SA Emitt Emitt Deck # Type Materials Color Absor. Tested Tested Insul. Pitch (deg) Hip Composition shingles Medium 0.85 No 0.9 No ATTIC # Type Ventilation Vent Ratio ( in) RBS IRCC Full attic Vented N N CEILING # Ceiling Type Space R-Value Ins Type Framing Frac Truss Type Under Attic (Vented) System 30 Batt Wood 6/5/207 5:7 PM EnergyGauge USA - FlaRes204 Section R Compliant Software Page 2 of 5

3 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt To Wall Type Space R-Value Ft In Ft In R-Value Fraction Absor. Grade% S Exterior Concrete Block - Int InsulSystem E Garage Frame - Wood System E Garage Frame - Wood System S Garage Frame - Wood System S Garage Frame - Wood System S Garage Frame - Wood System E Exterior Concrete Block - Int InsulSystem N Exterior Concrete Block - Int InsulSystem W Exterior Concrete Block - Int InsulSystem E Exterior Concrete Block - Int InsulSystem N Exterior Concrete Block - Int InsulSystem W Exterior Concrete Block - Int InsulSystem N Exterior Concrete Block - Int InsulSystem W Exterior Concrete Block - Int InsulSystem W Exterior Concrete Block - Int InsulSystem S Exterior Concrete Block - Int InsulSystem W Exterior Concrete Block - Int InsulSystem S Exterior Concrete Block - Int InsulSystem DOORS # Ornt Door Type Space Storms U-Value Width Height Ft In Ft In E Insulated System WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Depth Separation Int Shade S Metal Single (Tinted) Yes ft 0 in S Metal Single (Tinted) Yes ft 0 in S Metal Single (Tinted) Yes ft 0 in 0.5 ft 0 in 4 E 7 Metal Single (Tinted) Yes ft 0 in E 0 Metal Single (Tinted) Yes ft 0 in.333 ft 0 6 W 9 Metal Single (Tinted) Yes ft 0 in.47 ft 0 7 N Metal Single (Tinted) Yes ft 0 in.333 ft 0 8 N 3 Metal Single (Tinted) Yes ft 0 in.67 ft 0 9 W 5 Metal Single (Tinted) Yes ft 0 in S 6 Metal Single (Tinted) Yes ft 0 in.67 ft 0 Screening 6/5/207 5:7 PM EnergyGauge USA - FlaRes204 Section R Compliant Software Page 3 of 5

4 GARAGE # Floor Ceiling Exposed Wall Perimeter Avg. Wall Height Exposed Wall ft 9.33 ft INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 Wholehouse Proposed ACH(50) HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts Electric Strip Heat COP: 34 kbtu/hr sys# COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Central Unit SEER: 6 35 kbtu/hr 200 cfm 0.75 Ducts sys# HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation Electric Garage gal 60 gal 20 deg SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Volume FEF DUCTS ---- Supply Return ---- # Location R-Value Location Leakage Type Air Handler CFM 25 TOT CFM25 OUT QN RLF HVAC # Heat Cool Attic ft Attic 76.5 ft Default Leakage Garage (Default) (Default) 6/5/207 5:7 PM EnergyGauge USA - FlaRes204 Section R Compliant Software Page 4 of 5

5 Programable Thermostat: Y TEMPERATURES Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type Cooling (WD) AM PM Cooling (WEH) AM PM Heating (WD) AM PM Heating (WEH) AM PM 6/5/207 5:7 PM EnergyGauge USA - FlaRes204 Section R Compliant Software Page 5 of 5

6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 45 Lilac Ct, West Palm Beach, FL,. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area () 7. Windows** a. U-Factor: b. U-Factor: c. U-Factor: d. U-Factor: Description Sgl, U=.07 SHGC=0.53 Weighted Average Overhang Depth: Weighted Average 8. Floor Types a. Slab-On-Grade Edge b. c. New (From Plans) Single-family 3 No ft R= R= R= 9. Wall Types a. Concrete Block - Int Insul, Exterior R= b. Frame - Wood, Adjacent R= c. R= d. R= 0. Ceiling Types a. Under Attic (Vented) R= b. R= c. R=. Ducts R a. Sup: Attic, Ret: Attic, AH: Garage Cooling systems kbtu/hr Efficiency a. Central Unit 35.0 SEER: Heating systems kbtu/hr Efficiency a. Electric Strip Heat 34.0 COP: Hot water systems a. Electric b. Conservation features Cap: 40 gallons EF: Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (32) or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/5/207 5:8 PM EnergyGauge USA - FlaRes204 - Section R Compliant Software Page of