Energy Code Inspection Checklist

Size: px
Start display at page:

Download "Energy Code Inspection Checklist"

Transcription

1 / Building Information Conditioned Area (sq ft) 2558 Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) The building assemblies and the energy features listed below have been modeled to demonstrate compliance with the IECC utilizing the Simulated Performance Path. At times the energy features listed below will change in the field from what has been input in the analysis. 's field inspection process will identify any changes to ensure that the home continues to meet the intent of the IECC. Reports and certificates will be furnished before CO to ensure that the house meets the intent of the IECC. Ceilings [ ] 1. Attic: R-49 Blown, Attic (2094 s.f.) R-36.0 continuous insulation, R-13.0 cavity insulation. Name: Flat Insulation Grade: I II III Face / Inset [ ] 2. Attic: R-49 Blown, Attic (40 s.f.) R-36.0 continuous insulation, R-13.0 cavity insulation. Name: Flat Insulation Grade: I II III Face / Inset Above-Grade Walls [ ] 1. Wall: R-21 (1543 s.f.), Between conditioned space and ambient Name: 2x6 Insulation Grade: I II III Face / Inset [ ] 2. Wall: R-21 (410 s.f.), Between conditioned space and garage Name: 2x6 Garage Insulation Grade: I II III Face / Inset

2 / Above-Grade Walls [ ] 3. Wall: R-21 (635 s.f.), Between conditioned space and attic Name: 2x6 Attic Insulation Grade: I II III Face / Inset [ ] 4. Wall: R-11 (266 s.f.), Between cond and another cond unit (adiabatic) R-0.0 continuous insulation, R-11.0 cavity insulation. Name: 2x4 Party Insulation Grade: I II III Face / Inset [ ] 5. Wall: R-21 (131 s.f.), Between cond and another cond unit (adiabatic) Name: 2x6 Party Insulation Grade: I II III Face / Inset Windows and Skylights Window-to-Wall Area Ratio: 0.15 [ ] 1. Window: McKee All.32/.26 (178 s.f., South), U-Value: 0.320, SHGC: Name: Front Orientation: South [ ] 2. Window: McKee All.32/.26 (14 s.f., South), U-Value: 0.320, SHGC: Name: Front shade Orientation: South [ ] 3. Window: McKee All.32/.26 (5 s.f., South), U-Value: 0.320, SHGC: Name: Front shade Orientation: South Page 2 of 6

3 / Windows and Skylights [ ] 4. Window: McKee All.32/.26 (18 s.f., South), U-Value: 0.320, SHGC: Name: Front Shade Orientation: South [ ] 5. Window: McKee All.32/.26 (73 s.f., West), U-Value: 0.320, SHGC: Name: Left Orientation: West [ ] 6. Window: McKee All.32/.26 (36 s.f., West), U-Value: 0.320, SHGC: Name: Left Shade Orientation: West [ ] 7. Window: McKee All.32/.26 (21 s.f., West), U-Value: 0.320, SHGC: Name: Left Shade Orientation: West [ ] 8. Window: McKee All.32/.26 (18 s.f., East), U-Value: 0.320, SHGC: Name: Right Orientation: East [ ] 9. Window: McKee All.32/.26 (30 s.f., East), U-Value: 0.320, SHGC: Name: Right Orientation: East Doors [ ] 1. Door: 11P (21 s.f.), R-Value 3.4 Page 3 of 6

4 / Doors [ ] 2. Door: 11P (21 s.f.), R-Value 3.4 [ ] 3. Door: 11P (21 s.f.), R-Value 3.4 Frame Floors [ ] 1. Floor: Uninsulated (1814 s.f.), Between conditioned space and another (adiabatic) R-0.0 continuous insulation, R-0.0 cavity insulation. Name: Crawl Insulation Grade: I II III Face / Inset Slab Floors [ ] 1. Slab: Uninsulated (1814 s.f.) R-0.0 perimeter insulation, R-0.0 under slab insulation. Name: Slab Insulation Grade: I II III Face / Inset Foundation Walls [ ] 1. Wall: R-11 Draped, Full (650 s.f.), Between conditioned space and ambient/ground R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: Crawl Insulation Grade: I II III Face / Inset [ ] 2. Wall: R-11 Draped, Full (220 s.f.), Between cond and another cond unit (adiabatic) R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: Crawl - Party Insulation Grade: I II III Face / Inset Page 4 of 6

5 / Foundation Walls [ ] 3. Wall: R-11 Draped, Full (220 s.f.), Between conditioned space and garage/ground R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: Gar Insulation Grade: I II III Face / Inset Rim and Band Joists [ ] 1. Joist: 1st Fl (218 s.f.), Between conditioned space and ambient Name: 1st Fl Insulation Grade: I II III Face / Inset Mechanical Equipment [ ] 1. Heating: Fuel-fired air distribution, Natural gas, 92.0 AFUE. Make and Model Number [ ] 2. Cooling: Air conditioner, Electric, 14.0 SEER. Make and Model Number [ ] 3. Water Heating: Conventional, Electric, 0.91 EF, 50.0 Gal. Make and Model Number Mechanical Ventilation System [ ] Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only, 107 cfm, 24.0 hrs/day, 15.0 watts. System description(make) Air Leakage Control [ ] Blower Door Test at Final [ ] House is air-sealed so as to achieve 3.00 ACH50 or less at final blower door test. (Max CFM50 is: 1567) [ ] Visual inspection at rough for mandatory code air barrier and insulation features. Infiltration Requirements for IECC 2009 IECC Infiltration limit for the design home is 7 ACH50. Page 5 of 6

6 / Infiltration Requirements for IECC 2012 IECC Infiltration limit for the design home is 3 ACH IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage and Insulation [ ] Duct System 1 Leakage to Outside and Total Duct Leakage [ ] Duct System 1 Leakage to Outside is specified in REM/Rate at Pascals [ ] Duct System 1 Total Duct Leakage is specified in REM/Rate at Pascals Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA Performance Path (Cost Compliance): Requires ducts be tested and reported, but has no compliance thresholds. Notes Page 6 of 6