1 Charlotte Historic District Commission Application for a Certificate of Appropriateness Staff Review Date: January 10, 2018 HDC PID# LOCAL HISTORIC DISTRICT: PROPERTY ADDRESS: SUMMARY OF REQUEST: APPLICANT/OWNER: Dilworth 831 East Worthington Avenue (1826 Park Road) Front porch, site features, fenestration changes Allen Brooks Details of Proposed Request Existing Conditions The existing structure is a one Bungalow designed by William H. Peeps and listed as a contributing structure in the Dilworth National Register of Historic Places. Architectural features include a blend of styles including Four Square massing, and clipped gable end toward street. Full width façade porch, side shed dormers. House was reoriented from Worthington to Park. ca Vehicular access is along Park Road, adjacent to an alley easement. Project The project is the reorientation of the main entrance to Park Road, landscaping, fenestration changes and a new driveway pad. The existing right side gable end would be replaced with an entry door and brick stairs, the rear window widened to a casement window system, installation of a canopy over the left side door and shifting the existing front door back to its original location with a new window. Window sash kit replacements are noted on the elevations. Design Guidelines Replacement Windows, page Maintain the original size and shape of windows. 14. Match window replacements to the height and width of the original openings. 18. Give depth and profile to windows by using true divided lights, or three-part simulated divided lights with integral spacer bars and interior and exterior fixed muntins. Small variations such as the width and depth of the muntin and sash may be permitted if those variations do not significantly impact the historic characteristics of the window design. Clip-in/false muntins, flat muntins and removable external grilles are not allowed. 19. Replace a wood window with a wood window when possible. Wood-resin composite, aluminum clad wood, or fiberglass windows that meet these guidelines may be considered on a case by-case basis. Requests for vinyl windows must be reviewed by the full Historic District Commission. Design Guidelines - Porches, page Include a porch in the design of new residential construction when the majority of surrounding existing houses also contains a porch. 2. Design new porches to complement the size, proportion, placement and rhythm of existing historic porches within its context. 3. Ensure that the new porch is compatible with the overall architectural vocabulary/style of the new building. 4. Porches shall have a minimum depth of 8 feet. 1

2 5. Substitute materials are not allowed for front porch floors. Frame porches shall have tongue and groove floors laid perpendicular to front elevation of house. Staff Analysis The Commission will determine if the project meets the guidelines for porches, site features and fenestration changes. 2

3 Charlotte Historic District Commission Case HISTORIC DISTRICT: DILWORTH PORCH CHANGES East Bv Lennox Av E Worthington Av Park Rd Dilworth Rd West 831 E. Worthington Avenue Dilworth Historic District Feet January 4, 2018 Property Lines Building Footprints

4

5

6

7

8

9

10

11

12

13 INDEX OF DRAWINGS A-0.0 A-1.0 A-2.0 A-2.1 A-2.2 A-2.3 A-3.0 A-3.1 A-4.0 A-4.1 A-4.2 A-4.3 A-5.0 A-5.1 Cover Sheet Existing and Proposed Site Plans Existing Basement/Foundation Plan Existing First Floor Plan Existing Second Floor Plan\ Existing Roof Plan Existing Elevations Existing Elevations Proposed Basement/Foundation Plan(no change) Proposed First Floor Plan Proposed Second Floor Plan Proposed Roof Plan Proposed Elevations Proposed Elevations ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: OCT 2017 Seal VICINITY MAP This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. Unheated 361 S.F. 0 S.F. 270 S.F. 0 S.F. Proposed Rear Canopy: Proposed Left Side Porch: Total: Reuse or modification of these construction documents by the client, without the Architects permission, shall be at the client's sole risk, and the client agrees to indemnify and hold the Architect harmless for all claims, damages and expenses, including attorney fees, arising out of such reuse by client or by others acting through client. Total Under Roof: 26 S.F. 24 S.F. 681 S.F. 2,849 S.F. 3,530 S.F. PROJECT #: ISSUED: REVISIONS: 831 East Worthington Avenue, Charlotte, NC Existing Basement Floor: Existing First Floor: Covered Front Porch: Existing Second Floor: Heated 0 S.F S.F. 0 S.F S.F. Designed Exclusively For the: SQUARE FOOTAGE CALCULATIONS MENAKER RESIDENCE c ALBArchitecture OCT 2017 COVER SHEET A-0 OF: FIFTEEN

14

15

16

17 S 46 0' 0" E 49.6' S 46 0' 0" E 49.6' ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: brooks.alb@icloud.com lauer.alb@icloud.com ING BRICK PATIO 10' ALLEY TRELLIS CLIMB CONCRETE DRIVEWAY S 43 50' 47" W ' 10' ALLEY S 43 50' 47" W ' BAR 25 OCT 2017 R14'-0" RADIAL '-0" (GATE) 1'-8" 35' REAR SETBACK 4'-0" (GATE) 1'-8" 1'-8" 35' REAR SETBACK HIGH HEDGE 5' SIDE SETBACK LOW PLANTINGS RADIAL TABLE HERRING BONE GRASS LOW PLANTINGS TRELLIS PERMEABLE TURF STONE 5' SIDE SETBACK 10' SIDE SETBACK Seal BENCH 30'-0" This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. c ALBArchitecture 3' GATE N 44 0' 0" E ' 20' FRONT SETBACK CREPE MYRTLE ING RETAINING WALL PEBBLED STONE WALKWAY 3' GATE 3'-0" 10' SIDE SETBACK CREPE MYRTLE FENCE 3' GATE PARK ROAD N 44 0' 0" E ' CREPE MYRTLE 20' FRONT SETBACK RETAINING WALL RELOCATE HVAC PARK ROAD Designed Exclusively For the: MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC N 46 03' 32" W 50' N 46 03' 32" W 50' CURBSIDE CURBSIDE EAST WORTHINGTON AVENUE EAST WORTHINGTON AVENUE CONCRETE GRAVEL RETAINING WALL PAVER SYSTEM KEY: WALL TO BE REMOVED ITEM TO BE REMOVED PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: PROPOSED SITE PLAN 2 1' = 10'-0" ING SITE PLAN 1 1' = 10'-0" LEGEND: BOUNDARY LINE: OVERHEAD UTILITIES: FENCE (TYPE NOTED): UTILITY POLE: R/W: E/P: C/L: RIGHT OF WAY EDGE OF PAVEMENT CENTERLINE NORTH ING SITE PLAN A-1.0 OF: FIFTEEN

18

19

20

21

22

23

24

25

26 SALVAGE DOOR SCHEDULE NUM. OPENING LOCATION SD1 3'-0" x 6'-8" MAIN ENTRY DOOR SD2 3'-5" x 6'-8" DINING ROOM SD3 2'-10" x 6'-8" BEDROOM ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: TOP OF +24'-1 3/4" brooks.alb@icloud.com lauer.alb@icloud.com 6'-2 3/4" 2ND +17'-11" 25 OCT '-2" GENERAL NOTES: 2ND +9'-9" 10" 1ST +8'-11" 1ST +0'-0" 8'-11" 1. ALL PROPERTY LINES TO BE VERIFIED BY SURVEYOR. 2. ALL BUILDING LOCATIONS TO BE VERIFIED BY SURVEYOR. 3. FINISH GRADE TO BE COORDINATED BY CONTRACTOR. 4. ALL FINISH FLOOR HEIGHTS TO BE VERIFIED AT SITE & PRIOR TO CONSTRUCTION. 5. INTERIOR & EXTERIOR STAIR NOSING SHALL CONFORM TO R PROFILE - CURVATURE OF THE NOSING SHALL BE NO GREATER THAN 16" ALL RISERS TO BE SOLID. 7. ALL CASED OPENINGS TO MATCH DOOR MFG. - CONTRACTOR TO COORDINATE. 8. RAILS TO BE 36" IN HEIGHT 9. NO RAIL REQUIRED IF GRADE TO STOOPS & PORCHES IS LESS THAN 29" IN HEIGHT. 10. USE DOUBLE FELT FOR ALL PITCHES OF 4: OR LESS. 11. CONTRACTOR TO COORDINATE GUTTER & DOWNSPOUT LOCATIONS.. CONTINUOUS EAVE VENT U.N.O. 13. SALVAGED ORIGINAL WOOD SASHES (NOW STORED IN THE HOUSE BASEMENT) WILL BE REINSTALLED AT NON HISTORIC SASH REPLACEMENT LOCATIONS. c ALBArchitecture Seal This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. ING RIGHT SIDE ELEVATION 2 1/4" = 1'-0" SD1 REPLACE WINDOWS WITH ORIGINAL SASHES DOOR TO BE SALVAGED TOP OF +24'-1 3/4" 1ST +0'-0" 6'-2 3/4" 2ND +17'-11" 8'-2" 2ND +9'-9" 10" 1ST +8'-11" ING PILASTER AROUND THE DOOR TO BE REMOVED REPLACE WINDOWS WITH ORIGINAL SASHES 8'-11" STAIRS, RAILING & GUARD NOTES: 1. R WIDTH - STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT. - SEE PLANS FOR CLEAR WIDTH EXCEPTION DOES NOT APPLY TO THIS PROJECT. 2. R RISER HEIGHT - THE MAXIMUM RISER HEIGHT SHALL BE INCHES ALB SPECIFIES MAXIMUM RISER HEIGHT SHALL BE 8 INCHES FOR THIS PROJECT. 3. R TREAD DEPTH - THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 4. R HANDRAILS - HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS WITH FOUR OF MORE RISERS. 5. R HANDRAIL HEIGHT - HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES IN HEIGHT. 6. R3.2 GUARD HEIGHT - GUARDS SHALL NOT BE LESS THAN 36 INCHS 6.1. EXCEPTIONS 1 & 2 APPLY TO PROJECT - GUARD HEIGHT SHALL NOT BE LESS HAN 34 INCHES IF ON THE OPEN SIDE OF STAIR & SERVES AS THE RAILING. 7. R3.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER EXCEPTIONS 1 & 2 APPLY TO PROJECT - OPEN SIDE OF STAIR SHALL NOT ALLOW PASSAGE OF A 6 INCH SPHERE IN DIAMETER AT THE TRIANGULAR OPENINGS (BETWEEN BOTTOM RAIL, TREAD AND RISER). GUARDS SHALL NOT ALLOW PASSAGE OF A DIAMETER SPHERE ON OPEN SIDE OF STAIR. 1. REUSE OR MODIFICATION OF THESE CONSTRUCTION DOCUMENTS BY THE CLIENT, WITHOUT THE ARCHITECTS PERMISSION, SHALL BE AT THE CLIENT'S SOLE RISK, AND THE CLIENT AGREES TO INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FOR ALL CLAIMS, DAMAGES AND EXPENSES, INCLUDING ATTORNEY FEES ARISING OUT OF SUCH REUSE BY CLIENT OR BY OTHERS ACTING THROUGH CLIENT. 2. THESE DRAWINGS ARE NOT TO BE SCALED FOR ANY REASON, ALL DIMENSIONS TO BE FIELD VERIFIED. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT. Designed Exclusively For the: MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: ING FRONT ELEVATION 1 1/4" = 1'-0" KEY: WALL TO BE REMOVED ITEM TO BE REMOVED ING FRONT & RIGHT SIDE ELEVATION A-3.0 OF: FIFTEEN

27 SALVAGE DOOR SCHEDULE WINDOW SCHEDULE NUM. OPENING LOCATION ID SIZE HEADER HEIGHT TYPE SD1 3'-0" x 6'-8" MAIN ENTRY DOOR A 2'-8" X 6'-0" MATCH ING DOUBLE HUNG SD2 3'-5" x 6'-8" DINING ROOM B 6'-0" X 4'-8" (SEE ELEVATION) 8'-2" CASEMENT SD3 2'-10" x 6'-8" BEDROOM TOP OF + 24'-1 3/4" 6'-2 3/4" C D E 2'-8" X 6'-0" (ING OPENING) 2'-8" X 5'-0" (ING OPENING) 3'-0" X 4'-0" (ING OPENING) MATCH EXSITING MATCH EXSITING MATCH EXSITING DOUBLE HUNG (CHANGE SASH UNITS) DOUBLE HUNG (CHANGE SASH UNITS) DOUBLE HUNG (CHANGE SASH UNITS) 1. MATCH TRIM DETAILS WITH METAL DRIP CAP (WITH FLASHING) & BACK BAND TRIM AT WINDOWS. 2. SEE ELEVATIONS FOR MUNTIN PATTERN. VERIFY ANY REQUIREMENTS FOR EGRESS OR TEMPERED GLASS. 3. ALL WINDOWS WITH 9 SF OF GLASS OR MORE & LESS THAN 18" A.F.F. MUST BE TEMPERED. 4. PROVIDE FALL PROTECTION WHERE THE WINDOW IS LESS THAN 24" ABOVE A.F.F. AND GREATER THAN 72" ABOVE GRADE OR WALKING SURFACE BELOW. 5. WINDOW SIZING: 5.1. NEW CONSTRUCTION - DIMENSIONS BASED ON KOLBE ULTRA SERIES DIMENSIONS FOR ADDITIONS & REMODELS - MATCH ING WINDOW & DOOR MFG. INSTALL WITH DRIP CAP AND FLASHING. SEE ELEVATIONS FOR MUNTIN PATTERN. VERIFY ANY REQUIREMENTS FOR EGRESS OR TEMPERED GLASS M.E. = MATCH ING 6. PRIOR TO ORDERING WINDOWS, SUBMIT SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL. ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: brooks.alb@icloud.com lauer.alb@icloud.com 2ND + 17'-11" 25 OCT 2017 GENERAL NOTES: METAL HANDRAIL WOOD STEPS BRICK STEPS 101 C C D A D 1'-0" SD1 3'-0" GRADE VARIES SLOPE TO DRAIN REPLACE SASH UNITS REPLACE SASH UNITS TOP OF + 24'-1 3/4" 6'-2 3/4" 2ND + 17'-11" 8'-2" 2ND + 9'-9" 10" 1ST + 8'-11" REALIGN COLUMNS EQUALLY (SEE PLANS FOR DETAILS) METAL HANDRAIL 8'-11" 8'-2" 2ND + 9'-9" 10" 1ST + 8'-11" 8'-11" FLANKING WALLS 1ST + 0'-0" BRICK STEPS PROPOSED RIGHT SIDE ELEVATION 2 1/4" = 1'-0" 1. ALL PROPERTY LINES TO BE VERIFIED BY SURVEYOR. 2. ALL BUILDING LOCATIONS TO BE VERIFIED BY SURVEYOR. 3. FINISH GRADE TO BE COORDINATED BY CONTRACTOR. 4. ALL FINISH FLOOR HEIGHTS TO BE VERIFIED AT SITE & PRIOR TO CONSTRUCTION. 5. INTERIOR & EXTERIOR STAIR NOSING SHALL CONFORM TO R PROFILE - CURVATURE OF THE NOSING SHALL BE NO GREATER THAN 16" ALL RISERS TO BE SOLID. 7. ALL CASED OPENINGS TO MATCH DOOR MFG. - CONTRACTOR TO COORDINATE. 8. RAILS TO BE 36" IN HEIGHT 9. NO RAIL REQUIRED IF GRADE TO STOOPS & PORCHES IS LESS THAN 29" IN HEIGHT. 10. USE DOUBLE FELT FOR ALL PITCHES OF 4: OR LESS. 11. CONTRACTOR TO COORDINATE GUTTER & DOWNSPOUT LOCATIONS.. CONTINUOUS EAVE VENT U.N.O. 13. SALVAGED ORIGINAL WOOD SASHES (NOW STORED IN THE HOUSE BASEMENT) WILL BE REINSTALLED AT NON HISTORIC SASH REPLACEMENT LOCATIONS. STAIRS, RAILING & GUARD NOTES: 1. R WIDTH - STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT. - SEE PLANS FOR CLEAR WIDTH EXCEPTION DOES NOT APPLY TO THIS PROJECT. 2. R RISER HEIGHT - THE MAXIMUM RISER HEIGHT SHALL BE INCHES ALB SPECIFIES MAXIMUM RISER HEIGHT SHALL BE 8 INCHES FOR THIS PROJECT. 3. R TREAD DEPTH - THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 4. R HANDRAILS - HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS WITH FOUR OF MORE RISERS. 5. R HANDRAIL HEIGHT - HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES IN HEIGHT. 6. R3.2 GUARD HEIGHT - GUARDS SHALL NOT BE LESS THAN 36 INCHS 6.1. EXCEPTIONS 1 & 2 APPLY TO PROJECT - GUARD HEIGHT SHALL NOT BE LESS HAN 34 INCHES IF ON THE OPEN SIDE OF STAIR & SERVES AS THE RAILING. 7. R3.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER EXCEPTIONS 1 & 2 APPLY TO PROJECT - OPEN SIDE OF STAIR SHALL NOT ALLOW PASSAGE OF A 6 INCH SPHERE IN DIAMETER AT THE TRIANGULAR OPENINGS (BETWEEN BOTTOM RAIL, TREAD AND RISER). GUARDS SHALL NOT ALLOW PASSAGE OF A DIAMETER SPHERE ON OPEN SIDE OF STAIR. 1. REUSE OR MODIFICATION OF THESE CONSTRUCTION DOCUMENTS BY THE CLIENT, WITHOUT THE ARCHITECTS PERMISSION, SHALL BE AT THE CLIENT'S SOLE RISK, AND THE CLIENT AGREES TO INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FOR ALL CLAIMS, DAMAGES AND EXPENSES, INCLUDING ATTORNEY FEES ARISING OUT OF SUCH REUSE BY CLIENT OR BY OTHERS ACTING THROUGH CLIENT. 2. THESE DRAWINGS ARE NOT TO BE SCALED FOR ANY REASON, ALL DIMENSIONS TO BE FIELD VERIFIED. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT. c ALBArchitecture Seal This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. Designed Exclusively For the: MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: FLANKING WALLS BEYOND 1ST + 0'-0" BRICK STEPS GRAPHIC SCALE 1/4" = 1'-0" GRADE VARIES PROPOSED FRONT ELEVATION 1 1/4" = 1'-0" PROPOSED FRONT AND RIGHT SIDE ELEVATION A OF: FIFTEEN

28 SALVAGE DOOR SCHEDULE NUM. OPENING LOCATION SD1 3'-0" x 6'-8" MAIN ENTRY DOOR SD2 3'-5" x 6'-8" DINING ROOM TOP OF + 24'-1 3/4" SD3 2'-10" x 6'-8" BEDROOM ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: '-2 3/4" brooks.alb@icloud.com lauer.alb@icloud.com 2ND + 17'-11" 8'-2" 2ND + 9'-9" 25 OCT " 1ST + 8'-11" GENERAL NOTES: ING LEFT SIDE ELEVATION 2 1/4" = 1'-0" 8'-11" 1ST + 0'-0" 10" BST - 0'-10" 8'-5" 1. ALL PROPERTY LINES TO BE VERIFIED BY SURVEYOR. 2. ALL BUILDING LOCATIONS TO BE VERIFIED BY SURVEYOR. 3. FINISH GRADE TO BE COORDINATED BY CONTRACTOR. 4. ALL FINISH FLOOR HEIGHTS TO BE VERIFIED AT SITE & PRIOR TO CONSTRUCTION. 5. INTERIOR & EXTERIOR STAIR NOSING SHALL CONFORM TO R PROFILE - CURVATURE OF THE NOSING SHALL BE NO GREATER THAN 16" ALL RISERS TO BE SOLID. 7. ALL CASED OPENINGS TO MATCH DOOR MFG. - CONTRACTOR TO COORDINATE. 8. RAILS TO BE 36" IN HEIGHT 9. NO RAIL REQUIRED IF GRADE TO STOOPS & PORCHES IS LESS THAN 29" IN HEIGHT. 10. USE DOUBLE FELT FOR ALL PITCHES OF 4: OR LESS. 11. CONTRACTOR TO COORDINATE GUTTER & DOWNSPOUT LOCATIONS.. CONTINUOUS EAVE VENT U.N.O. 13. SALVAGED ORIGINAL WOOD SASHES (NOW STORED IN THE HOUSE BASEMENT) WILL BE REINSTALLED AT NON HISTORIC SASH REPLACEMENT LOCATIONS. c ALBArchitecture Seal This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. REPLACE WINDOWS WITH ORIGINAL SASHES BST - 9'-3" TOP OF +24'-1 3/4" 1ST +0'-0" 6'-2 3/4" 2ND +17'-11" 8'-2" 2ND +9'-9" 10" 1ST +8'-11" 8'-11" 10" BST - 0'-10" 8'-5" STAIRS, RAILING & GUARD NOTES: 1. R WIDTH - STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT. - SEE PLANS FOR CLEAR WIDTH EXCEPTION DOES NOT APPLY TO THIS PROJECT. 2. R RISER HEIGHT - THE MAXIMUM RISER HEIGHT SHALL BE INCHES ALB SPECIFIES MAXIMUM RISER HEIGHT SHALL BE 8 INCHES FOR THIS PROJECT. 3. R TREAD DEPTH - THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 4. R HANDRAILS - HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS WITH FOUR OF MORE RISERS. 5. R HANDRAIL HEIGHT - HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES IN HEIGHT. 6. R3.2 GUARD HEIGHT - GUARDS SHALL NOT BE LESS THAN 36 INCHS 6.1. EXCEPTIONS 1 & 2 APPLY TO PROJECT - GUARD HEIGHT SHALL NOT BE LESS HAN 34 INCHES IF ON THE OPEN SIDE OF STAIR & SERVES AS THE RAILING. 7. R3.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER EXCEPTIONS 1 & 2 APPLY TO PROJECT - OPEN SIDE OF STAIR SHALL NOT ALLOW PASSAGE OF A 6 INCH SPHERE IN DIAMETER AT THE TRIANGULAR OPENINGS (BETWEEN BOTTOM RAIL, TREAD AND RISER). GUARDS SHALL NOT ALLOW PASSAGE OF A DIAMETER SPHERE ON OPEN SIDE OF STAIR. 1. REUSE OR MODIFICATION OF THESE CONSTRUCTION DOCUMENTS BY THE CLIENT, WITHOUT THE ARCHITECTS PERMISSION, SHALL BE AT THE CLIENT'S SOLE RISK, AND THE CLIENT AGREES TO INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FOR ALL CLAIMS, DAMAGES AND EXPENSES, INCLUDING ATTORNEY FEES ARISING OUT OF SUCH REUSE BY CLIENT OR BY OTHERS ACTING THROUGH CLIENT. 2. THESE DRAWINGS ARE NOT TO BE SCALED FOR ANY REASON, ALL DIMENSIONS TO BE FIELD VERIFIED. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT. Designed Exclusively For the: MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: BST - 9'-3" ING REAR ELEVATION 1 1/4" = 1'-0" KEY: WALL TO BE REMOVED ITEM TO BE REMOVED ING REAR & LEFT SIDE ELEVATION A-3.1 OF: FIFTEEN

29 SALVAGE DOOR SCHEDULE WINDOW SCHEDULE NUM. OPENING LOCATION ID SIZE HEADER HEIGHT TYPE SD1 3'-0" x 6'-8" MAIN ENTRY DOOR A 2'-8" X 6'-0" MATCH ING DOUBLE HUNG SD2 3'-5" x 6'-8" DINING ROOM B 6'-0" X 4'-8" (SEE ELEVATION) 8'-2" CASEMENT SD3 2'-10" x 6'-8" BEDROOM TOP OF + 24'-1 3/4" 6'-2 3/4" 2ND + 17'-11" 8'-2" C D E 2'-8" X 6'-0" (ING OPENING) 2'-8" X 5'-0" (ING OPENING) 3'-0" X 4'-0" (ING OPENING) MATCH EXSITING MATCH EXSITING MATCH EXSITING DOUBLE HUNG (CHANGE SASH UNITS) DOUBLE HUNG (CHANGE SASH UNITS) DOUBLE HUNG (CHANGE SASH UNITS) 1. MATCH TRIM DETAILS WITH METAL DRIP CAP (WITH FLASHING) & BACK BAND TRIM AT WINDOWS. 2. SEE ELEVATIONS FOR MUNTIN PATTERN. VERIFY ANY REQUIREMENTS FOR EGRESS OR TEMPERED GLASS. 3. ALL WINDOWS WITH 9 SF OF GLASS OR MORE & LESS THAN 18" A.F.F. MUST BE TEMPERED. 4. PROVIDE FALL PROTECTION WHERE THE WINDOW IS LESS THAN 24" ABOVE A.F.F. AND GREATER THAN 72" ABOVE GRADE OR WALKING SURFACE BELOW. 5. WINDOW SIZING: 5.1. NEW CONSTRUCTION - DIMENSIONS BASED ON KOLBE ULTRA SERIES DIMENSIONS FOR ADDITIONS & REMODELS - MATCH ING WINDOW & DOOR MFG. INSTALL WITH DRIP CAP AND FLASHING. SEE ELEVATIONS FOR MUNTIN PATTERN. VERIFY ANY REQUIREMENTS FOR EGRESS OR TEMPERED GLASS M.E. = MATCH ING 6. PRIOR TO ORDERING WINDOWS, SUBMIT SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL. ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: brooks.alb@icloud.com lauer.alb@icloud.com 25 OCT ND + 9'-9" 10" GENERAL NOTES: 4" 1.5 6'-6" GRADE VARIES 1ST + 8'-11" 8'-11" 1ST + 0'-0" PROPOSED LEFT SIDE ELEVATION 2 1/4" = 1'-0" 1. ALL PROPERTY LINES TO BE VERIFIED BY SURVEYOR. 2. ALL BUILDING LOCATIONS TO BE VERIFIED BY SURVEYOR. 3. FINISH GRADE TO BE COORDINATED BY CONTRACTOR. 4. ALL FINISH FLOOR HEIGHTS TO BE VERIFIED AT SITE & PRIOR TO CONSTRUCTION. 5. INTERIOR & EXTERIOR STAIR NOSING SHALL CONFORM TO R PROFILE - CURVATURE OF THE NOSING SHALL BE NO GREATER THAN 16" ALL RISERS TO BE SOLID. 7. ALL CASED OPENINGS TO MATCH DOOR MFG. - CONTRACTOR TO COORDINATE. 8. RAILS TO BE 36" IN HEIGHT 9. NO RAIL REQUIRED IF GRADE TO STOOPS & PORCHES IS LESS THAN 29" IN HEIGHT. 10. USE DOUBLE FELT FOR ALL PITCHES OF 4: OR LESS. 11. CONTRACTOR TO COORDINATE GUTTER & DOWNSPOUT LOCATIONS.. CONTINUOUS EAVE VENT U.N.O. 13. SALVAGED ORIGINAL WOOD SASHES (NOW STORED IN THE HOUSE BASEMENT) WILL BE REINSTALLED AT NON HISTORIC SASH REPLACEMENT LOCATIONS. c ALBArchitecture Seal This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. SLOPE TO DRAIN FLANKING WALLS BRICK STEPS 8" 6'-0" EQ EQ EQ B E 3'-0" GRADE VARIES EAVE AND FASCIA TO MATCH ING (RIGHT SIDE ELEVATION) TOP OF + 24'-1 3/4" 6'-2 3/4" 2ND + 17'-11" 8'-2" 2ND + 9'-9" 10" 1ST + 8'-11" 8'-11" 1ST + 0'-0" STAIRS, RAILING & GUARD NOTES: 1. R WIDTH - STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT. - SEE PLANS FOR CLEAR WIDTH EXCEPTION DOES NOT APPLY TO THIS PROJECT. 2. R RISER HEIGHT - THE MAXIMUM RISER HEIGHT SHALL BE INCHES ALB SPECIFIES MAXIMUM RISER HEIGHT SHALL BE 8 INCHES FOR THIS PROJECT. 3. R TREAD DEPTH - THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 4. R HANDRAILS - HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS WITH FOUR OF MORE RISERS. 5. R HANDRAIL HEIGHT - HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES IN HEIGHT. 6. R3.2 GUARD HEIGHT - GUARDS SHALL NOT BE LESS THAN 36 INCHS 6.1. EXCEPTIONS 1 & 2 APPLY TO PROJECT - GUARD HEIGHT SHALL NOT BE LESS HAN 34 INCHES IF ON THE OPEN SIDE OF STAIR & SERVES AS THE RAILING. 7. R3.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER EXCEPTIONS 1 & 2 APPLY TO PROJECT - OPEN SIDE OF STAIR SHALL NOT ALLOW PASSAGE OF A 6 INCH SPHERE IN DIAMETER AT THE TRIANGULAR OPENINGS (BETWEEN BOTTOM RAIL, TREAD AND RISER). GUARDS SHALL NOT ALLOW PASSAGE OF A DIAMETER SPHERE ON OPEN SIDE OF STAIR. 1. REUSE OR MODIFICATION OF THESE CONSTRUCTION DOCUMENTS BY THE CLIENT, WITHOUT THE ARCHITECTS PERMISSION, SHALL BE AT THE CLIENT'S SOLE RISK, AND THE CLIENT AGREES TO INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FOR ALL CLAIMS, DAMAGES AND EXPENSES, INCLUDING ATTORNEY FEES ARISING OUT OF SUCH REUSE BY CLIENT OR BY OTHERS ACTING THROUGH CLIENT. 2. THESE DRAWINGS ARE NOT TO BE SCALED FOR ANY REASON, ALL DIMENSIONS TO BE FIELD VERIFIED. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT. Designed Exclusively For the: MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: GRAPHIC SCALE 1/4" = 1'-0" PROPOSED REAR ELEVATION 1 1/4" = 1'-0" PROPOSED REAR & LEFT SIDE ELEVATION A OF: FIFTEEN

30 ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: ING CRAWLSPACE SEE STRUCTURAL FOR DETAILS AND VENT LOCATIONS 25 OCT 2017 WH GENERAL NOTES: ING BASEMENT SEE STRUCTURAL FOR DETAILS 8'-5" HT FROM FLOOR TO CEILING UP HVAC WINE ROOM 1. ALL PROPERTY LINES TO BE VERIFIED BY SURVEYOR. 2. ALL BUILDING LOCATIONS TO BE VERIFIED BY SURVEYOR. 3. FINISH GRADE TO BE COORDINATED BY CONTRACTOR. 4. ALL FINISH FLOOR HEIGHTS TO BE VERIFIED AT SITE & PRIOR TO CONSTRUCTION. 5. INTERIOR & EXTERIOR STAIR NOSING SHALL CONFORM TO R PROFILE - CURVATURE OF THE NOSING SHALL BE NO GREATER THAN 16" ALL RISERS TO BE SOLID. 7. ALL CASED OPENINGS TO MATCH DOOR MFG. - CONTRACTOR TO COORDINATE. 8. RAILS TO BE 36" IN HEIGHT 9. NO RAIL REQUIRED IF GRADE TO STOOPS & PORCHES IS LESS THAN 29" IN HEIGHT. 10. USE DOUBLE FELT FOR ALL PITCHES OF 4: OR LESS. 11. CONTRACTOR TO COORDINATE GUTTER & DOWNSPOUT LOCATIONS.. CONTINUOUS EAVE VENT U.N.O. 13. SALVAGED ORIGINAL WOOD SASHES (NOW STORED IN THE HOUSE BASEMENT) WILL BE REINSTALLED AT NON HISTORIC SASH REPLACEMENT LOCATIONS. c ALBArchitecture Seal This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. ING CRAWLSPACE SEE STRUCTURAL FOR DETAILS AND VENT LOCATIONS STAIRS, RAILING & GUARD NOTES: 1. R WIDTH - STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT. - SEE PLANS FOR CLEAR WIDTH EXCEPTION DOES NOT APPLY TO THIS PROJECT. 2. R RISER HEIGHT - THE MAXIMUM RISER HEIGHT SHALL BE INCHES ALB SPECIFIES MAXIMUM RISER HEIGHT SHALL BE 8 INCHES FOR THIS PROJECT. 3. R TREAD DEPTH - THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 4. R HANDRAILS - HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS WITH FOUR OF MORE RISERS. 5. R HANDRAIL HEIGHT - HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES IN HEIGHT. 6. R3.2 GUARD HEIGHT - GUARDS SHALL NOT BE LESS THAN 36 INCHS 6.1. EXCEPTIONS 1 & 2 APPLY TO PROJECT - GUARD HEIGHT SHALL NOT BE LESS HAN 34 INCHES IF ON THE OPEN SIDE OF STAIR & SERVES AS THE RAILING. 7. R3.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER EXCEPTIONS 1 & 2 APPLY TO PROJECT - OPEN SIDE OF STAIR SHALL NOT ALLOW PASSAGE OF A 6 INCH SPHERE IN DIAMETER AT THE TRIANGULAR OPENINGS (BETWEEN BOTTOM RAIL, TREAD AND RISER). GUARDS SHALL NOT ALLOW PASSAGE OF A DIAMETER SPHERE ON OPEN SIDE OF STAIR. 1. REUSE OR MODIFICATION OF THESE CONSTRUCTION DOCUMENTS BY THE CLIENT, WITHOUT THE ARCHITECTS PERMISSION, SHALL BE AT THE CLIENT'S SOLE RISK, AND THE CLIENT AGREES TO INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FOR ALL CLAIMS, DAMAGES AND EXPENSES, INCLUDING ATTORNEY FEES ARISING OUT OF SUCH REUSE BY CLIENT OR BY OTHERS ACTING THROUGH CLIENT. 2. THESE DRAWINGS ARE NOT TO BE SCALED FOR ANY REASON, ALL DIMENSIONS TO BE FIELD VERIFIED. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT. Designed Exclusively For the: MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: GRAPHIC SCALE 1/4" = 1'-0" ING FOUNDATION PLAN 1 1/4" = 1'-0" KEY: WALL TO BE REMOVED ITEM TO BE REMOVED NORTH ING BASEMENT/ FOUNDATION PLAN A-2.0 OF: FIFTEEN

31 ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: OCT 2017 GENERAL NOTES: 4"X4" WOODEN POST 6'-4" 4" 4" 4'-0" HVAC WH ING WINE ROOM 1. ALL PROPERTY LINES TO BE VERIFIED BY SURVEYOR. 2. ALL BUILDING LOCATIONS TO BE VERIFIED BY SURVEYOR. 3. FINISH GRADE TO BE COORDINATED BY CONTRACTOR. 4. ALL FINISH FLOOR HEIGHTS TO BE VERIFIED AT SITE & PRIOR TO CONSTRUCTION. 5. INTERIOR & EXTERIOR STAIR NOSING SHALL CONFORM TO R PROFILE - CURVATURE OF THE NOSING SHALL BE NO GREATER THAN 16" ALL RISERS TO BE SOLID. 7. ALL CASED OPENINGS TO MATCH DOOR MFG. - CONTRACTOR TO COORDINATE. 8. RAILS TO BE 36" IN HEIGHT 9. NO RAIL REQUIRED IF GRADE TO STOOPS & PORCHES IS LESS THAN 29" IN HEIGHT. 10. USE DOUBLE FELT FOR ALL PITCHES OF 4: OR LESS. 11. CONTRACTOR TO COORDINATE GUTTER & DOWNSPOUT LOCATIONS.. CONTINUOUS EAVE VENT U.N.O. 13. SALVAGED ORIGINAL WOOD SASHES (NOW STORED IN THE HOUSE BASEMENT) WILL BE REINSTALLED AT NON HISTORIC SASH REPLACEMENT LOCATIONS. STAIRS, RAILING & GUARD NOTES: 1. R WIDTH - STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT. - SEE PLANS FOR CLEAR WIDTH EXCEPTION DOES NOT APPLY TO THIS PROJECT. 2. R RISER HEIGHT - THE MAXIMUM RISER HEIGHT SHALL BE INCHES ALB SPECIFIES MAXIMUM RISER HEIGHT SHALL BE 8 INCHES FOR THIS PROJECT. 3. R TREAD DEPTH - THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 4. R HANDRAILS - HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS WITH FOUR OF MORE RISERS. 5. R HANDRAIL HEIGHT - HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES IN HEIGHT. 6. R3.2 GUARD HEIGHT - GUARDS SHALL NOT BE LESS THAN 36 INCHS 6.1. EXCEPTIONS 1 & 2 APPLY TO PROJECT - GUARD HEIGHT SHALL NOT BE LESS HAN 34 INCHES IF ON THE OPEN SIDE OF STAIR & SERVES AS THE RAILING. 7. R3.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER EXCEPTIONS 1 & 2 APPLY TO PROJECT - OPEN SIDE OF STAIR SHALL NOT ALLOW PASSAGE OF A 6 INCH SPHERE IN DIAMETER AT THE TRIANGULAR OPENINGS (BETWEEN BOTTOM RAIL, TREAD AND RISER). GUARDS SHALL NOT ALLOW PASSAGE OF A DIAMETER SPHERE ON OPEN SIDE OF STAIR. 1. REUSE OR MODIFICATION OF THESE CONSTRUCTION DOCUMENTS BY THE CLIENT, WITHOUT THE ARCHITECTS PERMISSION, SHALL BE AT THE CLIENT'S SOLE RISK, AND THE CLIENT AGREES TO INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FOR ALL CLAIMS, DAMAGES AND EXPENSES, INCLUDING ATTORNEY FEES ARISING OUT OF SUCH REUSE BY CLIENT OR BY OTHERS ACTING THROUGH CLIENT. 2. THESE DRAWINGS ARE NOT TO BE SCALED FOR ANY REASON, ALL DIMENSIONS TO BE FIELD VERIFIED. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT. c ALBArchitecture Seal This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. Designed Exclusively For the: MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: PROPOSED FOUNDATION PLAN GRAPHIC SCALE 1/4" = 1'-0" PROPOSED FOUNDATION PLAN 1 1/4" = 1'-0" 10" CONCRETE STUD WALL FURRED WALL 4" WALL NORTH A-4.0 OF: FIFTEEN

32 SALVAGE DOOR SCHEDULE NUM. OPENING LOCATION SD1 3'-0" x 6'-8" MAIN ENTRY DOOR SD2 3'-5" x 6'-8" DINING ROOM SD3 2'-10" x 6'-8" BEDROOM ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: STORAGE KITCHEN brooks.alb@icloud.com lauer.alb@icloud.com PANTRY ING CHIMNEY TO REMAIN (BRICK TO BE EXPOSED) POWDER ROOM CHIMNEY BREAKFAST NOOK 25 OCT 2017 CLOSET GENERAL NOTES: BEDROOM SD3 DN UP HALLWAY BATHROOM SD2 DINING ROOM 1. ALL PROPERTY LINES TO BE VERIFIED BY SURVEYOR. 2. ALL BUILDING LOCATIONS TO BE VERIFIED BY SURVEYOR. 3. FINISH GRADE TO BE COORDINATED BY CONTRACTOR. 4. ALL FINISH FLOOR HEIGHTS TO BE VERIFIED AT SITE & PRIOR TO CONSTRUCTION. 5. INTERIOR & EXTERIOR STAIR NOSING SHALL CONFORM TO R PROFILE - CURVATURE OF THE NOSING SHALL BE NO GREATER THAN 16" ALL RISERS TO BE SOLID. 7. ALL CASED OPENINGS TO MATCH DOOR MFG. - CONTRACTOR TO COORDINATE. 8. RAILS TO BE 36" IN HEIGHT 9. NO RAIL REQUIRED IF GRADE TO STOOPS & PORCHES IS LESS THAN 29" IN HEIGHT. 10. USE DOUBLE FELT FOR ALL PITCHES OF 4: OR LESS. 11. CONTRACTOR TO COORDINATE GUTTER & DOWNSPOUT LOCATIONS.. CONTINUOUS EAVE VENT U.N.O. 13. SALVAGED ORIGINAL WOOD SASHES (NOW STORED IN THE HOUSE BASEMENT) WILL BE REINSTALLED AT NON HISTORIC SASH REPLACEMENT LOCATIONS. c ALBArchitecture Seal This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. CLOSET LIVING ROOM SHOWER SD1 FRONT PORCH COLUMNS TO BE REALIGNED DN GREAT ROOM TO BE REMOVED MEDIA STAIRS, RAILING & GUARD NOTES: 1. R WIDTH - STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT. - SEE PLANS FOR CLEAR WIDTH EXCEPTION DOES NOT APPLY TO THIS PROJECT. 2. R RISER HEIGHT - THE MAXIMUM RISER HEIGHT SHALL BE INCHES ALB SPECIFIES MAXIMUM RISER HEIGHT SHALL BE 8 INCHES FOR THIS PROJECT. 3. R TREAD DEPTH - THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 4. R HANDRAILS - HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS WITH FOUR OF MORE RISERS. 5. R HANDRAIL HEIGHT - HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES IN HEIGHT. 6. R3.2 GUARD HEIGHT - GUARDS SHALL NOT BE LESS THAN 36 INCHS 6.1. EXCEPTIONS 1 & 2 APPLY TO PROJECT - GUARD HEIGHT SHALL NOT BE LESS HAN 34 INCHES IF ON THE OPEN SIDE OF STAIR & SERVES AS THE RAILING. 7. R3.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER EXCEPTIONS 1 & 2 APPLY TO PROJECT - OPEN SIDE OF STAIR SHALL NOT ALLOW PASSAGE OF A 6 INCH SPHERE IN DIAMETER AT THE TRIANGULAR OPENINGS (BETWEEN BOTTOM RAIL, TREAD AND RISER). GUARDS SHALL NOT ALLOW PASSAGE OF A DIAMETER SPHERE ON OPEN SIDE OF STAIR. 1. REUSE OR MODIFICATION OF THESE CONSTRUCTION DOCUMENTS BY THE CLIENT, WITHOUT THE ARCHITECTS PERMISSION, SHALL BE AT THE CLIENT'S SOLE RISK, AND THE CLIENT AGREES TO INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FOR ALL CLAIMS, DAMAGES AND EXPENSES, INCLUDING ATTORNEY FEES ARISING OUT OF SUCH REUSE BY CLIENT OR BY OTHERS ACTING THROUGH CLIENT. 2. THESE DRAWINGS ARE NOT TO BE SCALED FOR ANY REASON, ALL DIMENSIONS TO BE FIELD VERIFIED. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT. Designed Exclusively For the: MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: ING 1ST FLOOR PLAN GRAPHIC SCALE 1/4" = 1'-0" ING FIRST FLOOR PLAN 1 1/4" = 1'-0" KEY: WALL TO BE REMOVED ITEM TO BE REMOVED NORTH A-2.1 OF: FIFTEEN

33 FIRST FLOOR DOOR SCHEDULE WINDOW SCHEDULE NUM. OPENING LOCATION ID SIZE HEADER HEIGHT TYPE 101 3'-0" x 6'-8" SIDE ENTRY DOOR A 2'-8" X 6'-0" MATCH ING DOUBLE HUNG 102 2'-6" x 6'-8" (POCKET DOOR WITH 1'-0" TRANSOM) MASTER CLOSET B 6'-0" X 4'-8" (SEE ELEVATION) 8'-2" CASEMENT GUARDS ON OPEN SIDE OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3 8" IN DIAMETER PER R3.3 8" 1 1 4" 10" 1 2" 3'-0" EXTERIOR STAIR SHALL BE COORDINATED WITH FINISH GRADE AND SHALL HAVE PROTECTION AGAINST DECAY HOGGING BLOCK BRICK STAIR DETAIL 3 1/2" = 1'-0" GUARDS ON OPEN SIDE OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3 8" IN DIAMETER PER R3.3 3'-0" 7 1 4" 3/4" 10" EXTERIOR STAIR SHALL BE COORDINATED WITH FINISH GRADE AND SHALL HAVE PROTECTION AGAINST DECAY WOOD STAIR DETAIL 2 1/2" = 1'-0" 1/4" ADDED CANOPY (SEE ELEVATIONS) ING STORAGE W/D MASTER BEDROOM TV 6'-8" 4'-0" W/C 4'-2 1/2" 105 LAUNDRY SHELVES ING POWDER ROOM 4'-8 1/2" 6'-0 1/2" 4'-9" 5'-10" 103 C 102 ALIGN 104 2'-0" 10'-9 1/2" C/O 2'-0" 2'-8" C/O MASTER BATHROOM WALK IN CLOSET REF (REUSE) 1'-8 1/2" HIGH BOY DRESSER DN 15' R ARCHED OPENING UP ING HALLWAY SD3 SHOWER LINEN KITCHEN CHIMNEY PIANO CHINA DW 4'-0" 3'-0" 3'-0" TABLE RELOCATE THE DRAIN PIPES ING FRONT PORCH ING CHIMNEY WITH PLASTER ABOVE A WAINSCOT OF CERAMIC SUBWAY TILE SD2 RANGE 2'-5" 15' R ARCHED OPENING 4" C ADDED CANOPY (SEE ELEVATIONS) B ING COLUMNS REALIGNED 5'-3 3/4" 2'-4 1/2" TV DINING ROOM LIVING ROOM PANTRY/STORAGE SD1 A 2'-0 1/2" 2'-0 1/2" BUFFET DN 2'-4" x 6'-8" (WITH 1-0"TRANSOM) PR 2'-8" x 6'-8" (WITH 1'-0" TRANSOM) CLOSET MEDIA 2'-8" x 6'-8" (SLIDING DOOR) 101 ADDED EAVES (SEE ELEVATIONS) 3'-0" 2'-10 1/2" DN METAL HANDRAIL 1'-4" 4'-6" 1'-4" RESTORE DOOR TO ITS ORIGINAL LOCATION WOOD STEPS BRICK STEPS 7'-2" W/C MASTER BATHROOM LAUNDRY C D E 2'-8" X 6'-0" (ING OPENING) 2'-8" X 5'-0" (ING OPENING) 3'-0" X 4'-0" (ING OPENING) MATCH EXSITING MATCH EXSITING MATCH EXSITING DOUBLE HUNG (CHANGE SASH UNITS) DOUBLE HUNG (CHANGE SASH UNITS) DOUBLE HUNG (CHANGE SASH UNITS) 1. MATCH TRIM DETAILS WITH METAL DRIP CAP (WITH FLASHING) & BACK BAND TRIM AT WINDOWS. 2. SEE ELEVATIONS FOR MUNTIN PATTERN. VERIFY ANY REQUIREMENTS FOR EGRESS OR TEMPERED GLASS. 3. ALL WINDOWS WITH 9 SF OF GLASS OR MORE & LESS THAN 18" A.F.F. MUST BE TEMPERED. 4. PROVIDE FALL PROTECTION WHERE THE WINDOW IS LESS THAN 24" ABOVE A.F.F. AND GREATER THAN 72" ABOVE GRADE OR WALKING SURFACE BELOW. 5. WINDOW SIZING: 5.1. NEW CONSTRUCTION - DIMENSIONS BASED ON KOLBE ULTRA SERIES DIMENSIONS FOR ADDITIONS & REMODELS - MATCH ING WINDOW & DOOR MFG. INSTALL WITH DRIP CAP AND FLASHING. SEE ELEVATIONS FOR MUNTIN PATTERN. VERIFY ANY REQUIREMENTS FOR EGRESS OR TEMPERED GLASS M.E. = MATCH ING 6. PRIOR TO ORDERING WINDOWS, SUBMIT SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL. GENERAL NOTES: 1. ALL PROPERTY LINES TO BE VERIFIED BY SURVEYOR. 2. ALL BUILDING LOCATIONS TO BE VERIFIED BY SURVEYOR. 3. FINISH GRADE TO BE COORDINATED BY CONTRACTOR. 4. ALL FINISH FLOOR HEIGHTS TO BE VERIFIED AT SITE & PRIOR TO CONSTRUCTION. 5. INTERIOR & EXTERIOR STAIR NOSING SHALL CONFORM TO R PROFILE - CURVATURE OF THE NOSING SHALL BE NO GREATER THAN 16" ALL RISERS TO BE SOLID. 7. ALL CASED OPENINGS TO MATCH DOOR MFG. - CONTRACTOR TO COORDINATE. 8. RAILS TO BE 36" IN HEIGHT 9. NO RAIL REQUIRED IF GRADE TO STOOPS & PORCHES IS LESS THAN 29" IN HEIGHT. 10. USE DOUBLE FELT FOR ALL PITCHES OF 4: OR LESS. 11. CONTRACTOR TO COORDINATE GUTTER & DOWNSPOUT LOCATIONS.. CONTINUOUS EAVE VENT U.N.O. 13. SALVAGED ORIGINAL WOOD SASHES (NOW STORED IN THE HOUSE BASEMENT) WILL BE REINSTALLED AT NON HISTORIC SASH REPLACEMENT LOCATIONS. STAIRS, RAILING & GUARD NOTES: 1. R WIDTH - STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT. - SEE PLANS FOR CLEAR WIDTH EXCEPTION DOES NOT APPLY TO THIS PROJECT. 2. R RISER HEIGHT - THE MAXIMUM RISER HEIGHT SHALL BE INCHES ALB SPECIFIES MAXIMUM RISER HEIGHT SHALL BE 8 INCHES FOR THIS PROJECT. 3. R TREAD DEPTH - THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 4. R HANDRAILS - HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS WITH FOUR OF MORE RISERS. 5. R HANDRAIL HEIGHT - HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES IN HEIGHT. 6. R3.2 GUARD HEIGHT - GUARDS SHALL NOT BE LESS THAN 36 INCHS 6.1. EXCEPTIONS 1 & 2 APPLY TO PROJECT - GUARD HEIGHT SHALL NOT BE LESS HAN 34 INCHES IF ON THE OPEN SIDE OF STAIR & SERVES AS THE RAILING. 7. R3.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER EXCEPTIONS 1 & 2 APPLY TO PROJECT - OPEN SIDE OF STAIR SHALL NOT ALLOW PASSAGE OF A 6 INCH SPHERE IN DIAMETER AT THE TRIANGULAR OPENINGS (BETWEEN BOTTOM RAIL, TREAD AND RISER). GUARDS SHALL NOT ALLOW PASSAGE OF A DIAMETER SPHERE ON OPEN SIDE OF STAIR. 1. REUSE OR MODIFICATION OF THESE CONSTRUCTION DOCUMENTS BY THE CLIENT, WITHOUT THE ARCHITECTS PERMISSION, SHALL BE AT THE CLIENT'S SOLE RISK, AND THE CLIENT AGREES TO INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FOR ALL CLAIMS, DAMAGES AND EXPENSES, INCLUDING ATTORNEY FEES ARISING OUT OF SUCH REUSE BY CLIENT OR BY OTHERS ACTING THROUGH CLIENT. 2. THESE DRAWINGS ARE NOT TO BE SCALED FOR ANY REASON, ALL DIMENSIONS TO BE FIELD VERIFIED. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT. ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: brooks.alb@icloud.com lauer.alb@icloud.com c ALBArchitecture Designed Exclusively For the: 25 OCT 2017 Seal This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: C L 8'-10 1/2" C L 8'-10 1/2" C L 8'-10 1/2" C L GRAPHIC SCALE 1/4" = 1'-0" PROPOSED FIRST FLOOR PLAN 1 1/4" = 1'-0" 10" CONCRETE STUD WALL FURRED WALL 4" WALL NORTH PROPOSED 1ST FLOOR PLAN A-4.1 OF: FIFTEEN

34 SALVAGE DOOR SCHEDULE NUM. OPENING LOCATION SD1 3'-0" x 6'-8" MAIN ENTRY DOOR SD2 3'-5" x 6'-8" DINING ROOM SD3 2'-10" x 6'-8" BEDROOM ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: BEDROOM 'A' brooks.alb@icloud.com lauer.alb@icloud.com CLOSET 25 OCT 2017 GENERAL NOTES: STORAGE W/D LAUNDRY DOOR TO SWING TOWARDS INDIDE DN HALLWAY BATHROOM 'A' BATHROOM 'B' 1. ALL PROPERTY LINES TO BE VERIFIED BY SURVEYOR. 2. ALL BUILDING LOCATIONS TO BE VERIFIED BY SURVEYOR. 3. FINISH GRADE TO BE COORDINATED BY CONTRACTOR. 4. ALL FINISH FLOOR HEIGHTS TO BE VERIFIED AT SITE & PRIOR TO CONSTRUCTION. 5. INTERIOR & EXTERIOR STAIR NOSING SHALL CONFORM TO R PROFILE - CURVATURE OF THE NOSING SHALL BE NO GREATER THAN 16" ALL RISERS TO BE SOLID. 7. ALL CASED OPENINGS TO MATCH DOOR MFG. - CONTRACTOR TO COORDINATE. 8. RAILS TO BE 36" IN HEIGHT 9. NO RAIL REQUIRED IF GRADE TO STOOPS & PORCHES IS LESS THAN 29" IN HEIGHT. 10. USE DOUBLE FELT FOR ALL PITCHES OF 4: OR LESS. 11. CONTRACTOR TO COORDINATE GUTTER & DOWNSPOUT LOCATIONS.. CONTINUOUS EAVE VENT U.N.O. 13. SALVAGED ORIGINAL WOOD SASHES (NOW STORED IN THE HOUSE BASEMENT) WILL BE REINSTALLED AT NON HISTORIC SASH REPLACEMENT LOCATIONS. c ALBArchitecture Seal This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. SHOWER BEDROOM 'B' STAIRS, RAILING & GUARD NOTES: 1. R WIDTH - STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT. - SEE PLANS FOR CLEAR WIDTH EXCEPTION DOES NOT APPLY TO THIS PROJECT. 2. R RISER HEIGHT - THE MAXIMUM RISER HEIGHT SHALL BE INCHES ALB SPECIFIES MAXIMUM RISER HEIGHT SHALL BE 8 INCHES FOR THIS PROJECT. 3. R TREAD DEPTH - THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 4. R HANDRAILS - HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS WITH FOUR OF MORE RISERS. 5. R HANDRAIL HEIGHT - HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES IN HEIGHT. 6. R3.2 GUARD HEIGHT - GUARDS SHALL NOT BE LESS THAN 36 INCHS 6.1. EXCEPTIONS 1 & 2 APPLY TO PROJECT - GUARD HEIGHT SHALL NOT BE LESS HAN 34 INCHES IF ON THE OPEN SIDE OF STAIR & SERVES AS THE RAILING. 7. R3.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER EXCEPTIONS 1 & 2 APPLY TO PROJECT - OPEN SIDE OF STAIR SHALL NOT ALLOW PASSAGE OF A 6 INCH SPHERE IN DIAMETER AT THE TRIANGULAR OPENINGS (BETWEEN BOTTOM RAIL, TREAD AND RISER). GUARDS SHALL NOT ALLOW PASSAGE OF A DIAMETER SPHERE ON OPEN SIDE OF STAIR. 1. REUSE OR MODIFICATION OF THESE CONSTRUCTION DOCUMENTS BY THE CLIENT, WITHOUT THE ARCHITECTS PERMISSION, SHALL BE AT THE CLIENT'S SOLE RISK, AND THE CLIENT AGREES TO INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FOR ALL CLAIMS, DAMAGES AND EXPENSES, INCLUDING ATTORNEY FEES ARISING OUT OF SUCH REUSE BY CLIENT OR BY OTHERS ACTING THROUGH CLIENT. 2. THESE DRAWINGS ARE NOT TO BE SCALED FOR ANY REASON, ALL DIMENSIONS TO BE FIELD VERIFIED. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT. Designed Exclusively For the: MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: ING 2ND FLOOR PLAN GRAPHIC SCALE 1/4" = 1'-0" ING SECOND FLOOR PLAN 1 1/4" = 1'-0" KEY: WALL TO BE REMOVED ITEM TO BE REMOVED NORTH A-2.2 OF: FIFTEEN

35 SECOND FLOOR DOOR SCHEDULE WINDOW SCHEDULE NUM. OPENING LOCATION ID SIZE HEADER HEIGHT TYPE ADDED CANOPY (SEE ELEVATIONS) 201 2'-8" x 6'-8" ING BEDROOM 'B' A 2'-8" X 6'-0" MATCH ING DOUBLE HUNG ADDED CANOPY (SEE ELEVATIONS) ING CLOSET E ING BEDROOM 'A' EXPOSE CHIMNEY ALIGN '-4" x 6'-8" 2'-0" x 6'-8" 2'-0" x 6'-8" ADDED EAVES (SEE ELEVATIONS) BATHROOM CLOSET CLOSET B C D E 6'-0" X 4'-8" (SEE ELEVATION) 2'-8" X 6'-0" (ING OPENING) 2'-8" X 5'-0" (ING OPENING) 3'-0" X 4'-0" (ING OPENING) 1. MATCH TRIM DETAILS WITH METAL DRIP CAP (WITH FLASHING) & BACK BAND TRIM AT WINDOWS. 2. SEE ELEVATIONS FOR MUNTIN PATTERN. VERIFY ANY REQUIREMENTS FOR EGRESS OR TEMPERED GLASS. 3. ALL WINDOWS WITH 9 SF OF GLASS OR MORE & LESS THAN 18" A.F.F. MUST BE TEMPERED. 4. PROVIDE FALL PROTECTION WHERE THE WINDOW IS LESS THAN 24" ABOVE A.F.F. AND GREATER THAN 72" ABOVE GRADE OR WALKING SURFACE BELOW. 5. WINDOW SIZING: 5.1. NEW CONSTRUCTION - DIMENSIONS BASED ON KOLBE ULTRA SERIES DIMENSIONS FOR ADDITIONS & REMODELS - MATCH ING WINDOW & DOOR MFG. INSTALL WITH DRIP CAP AND FLASHING. SEE ELEVATIONS FOR MUNTIN PATTERN. VERIFY ANY REQUIREMENTS FOR EGRESS OR TEMPERED GLASS M.E. = MATCH ING 6. PRIOR TO ORDERING WINDOWS, SUBMIT SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL. 8'-2" MATCH EXSITING MATCH EXSITING MATCH EXSITING CASEMENT DOUBLE HUNG (CHANGE SASH UNITS) DOUBLE HUNG (CHANGE SASH UNITS) DOUBLE HUNG (CHANGE SASH UNITS) ALB Architecture 00 E. Morehead St. Suite 240 Charlotte, NC Phone: brooks.alb@icloud.com lauer.alb@icloud.com 25 OCT 2017 GENERAL NOTES: SINK WASHER LAUNDRY DRYER ARCHED ALCOVE DN ING HALLWAY 2'-6" 3'-0" C/O 8" OPENING IN WALL DESK DEN REPOSITION FIXTURES ING BATHROOM TV 1. ALL PROPERTY LINES TO BE VERIFIED BY SURVEYOR. 2. ALL BUILDING LOCATIONS TO BE VERIFIED BY SURVEYOR. 3. FINISH GRADE TO BE COORDINATED BY CONTRACTOR. 4. ALL FINISH FLOOR HEIGHTS TO BE VERIFIED AT SITE & PRIOR TO CONSTRUCTION. 5. INTERIOR & EXTERIOR STAIR NOSING SHALL CONFORM TO R PROFILE - CURVATURE OF THE NOSING SHALL BE NO GREATER THAN 16" ALL RISERS TO BE SOLID. 7. ALL CASED OPENINGS TO MATCH DOOR MFG. - CONTRACTOR TO COORDINATE. 8. RAILS TO BE 36" IN HEIGHT 9. NO RAIL REQUIRED IF GRADE TO STOOPS & PORCHES IS LESS THAN 29" IN HEIGHT. 10. USE DOUBLE FELT FOR ALL PITCHES OF 4: OR LESS. 11. CONTRACTOR TO COORDINATE GUTTER & DOWNSPOUT LOCATIONS.. CONTINUOUS EAVE VENT U.N.O. 13. SALVAGED ORIGINAL WOOD SASHES (NOW STORED IN THE HOUSE BASEMENT) WILL BE REINSTALLED AT NON HISTORIC SASH REPLACEMENT LOCATIONS. c ALBArchitecture Seal This drawing and the design shown is the property of ALB Architecture and is not to be reproduced or copied in whole or in part. Its use on any other project is prohibited. This drawing is to be returned upon request. 3'-0" BATHROOM ELLIPTICAL 2'-0" 3'-8" 2'-7" CLOSET 203 2'-4" 6'-0" SHOWER 3'-4" 3'-9 1/2" 3'-4" 2'-9 1/2" 5'-2" 4'-3" 2'-2" 1'-10" 1'-8" 7'-7" CLOSET D 201 ING BEDROOM 'B' D OAK DESK 2'-4" EXPOSE CHIMNEY REUSE FRIDGE STAIRS, RAILING & GUARD NOTES: 1. R WIDTH - STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT. - SEE PLANS FOR CLEAR WIDTH EXCEPTION DOES NOT APPLY TO THIS PROJECT. 2. R RISER HEIGHT - THE MAXIMUM RISER HEIGHT SHALL BE INCHES ALB SPECIFIES MAXIMUM RISER HEIGHT SHALL BE 8 INCHES FOR THIS PROJECT. 3. R TREAD DEPTH - THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 4. R HANDRAILS - HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS WITH FOUR OF MORE RISERS. 5. R HANDRAIL HEIGHT - HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES IN HEIGHT. 6. R3.2 GUARD HEIGHT - GUARDS SHALL NOT BE LESS THAN 36 INCHS 6.1. EXCEPTIONS 1 & 2 APPLY TO PROJECT - GUARD HEIGHT SHALL NOT BE LESS HAN 34 INCHES IF ON THE OPEN SIDE OF STAIR & SERVES AS THE RAILING. 7. R3.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER EXCEPTIONS 1 & 2 APPLY TO PROJECT - OPEN SIDE OF STAIR SHALL NOT ALLOW PASSAGE OF A 6 INCH SPHERE IN DIAMETER AT THE TRIANGULAR OPENINGS (BETWEEN BOTTOM RAIL, TREAD AND RISER). GUARDS SHALL NOT ALLOW PASSAGE OF A DIAMETER SPHERE ON OPEN SIDE OF STAIR. 1. REUSE OR MODIFICATION OF THESE CONSTRUCTION DOCUMENTS BY THE CLIENT, WITHOUT THE ARCHITECTS PERMISSION, SHALL BE AT THE CLIENT'S SOLE RISK, AND THE CLIENT AGREES TO INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FOR ALL CLAIMS, DAMAGES AND EXPENSES, INCLUDING ATTORNEY FEES ARISING OUT OF SUCH REUSE BY CLIENT OR BY OTHERS ACTING THROUGH CLIENT. 2. THESE DRAWINGS ARE NOT TO BE SCALED FOR ANY REASON, ALL DIMENSIONS TO BE FIELD VERIFIED. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM ARCHITECT. Designed Exclusively For the: MENAKER RESIDENCE 831 East Worthington Avenue, Charlotte, NC PROJECT #: ISSUED: 25 OCT 2017 REVISIONS: GRAPHIC SCALE 1/4" = 1'-0" PROPOSED SECOND FLOOR PLAN 1 1/4" = 1'-0" 10" CONCRETE STUD WALL FURRED WALL 4" WALL NORTH PROPOSED 2ND FLOOR PLAN A-4.2 OF: FIFTEEN