1 DESIGN PACKAGE A WATER FEATURE HYDRAULIC DESIGN FOR COMMONS PARK Twin Falls, Idaho P16375-R Prepared by FOUNTAIN PEOPLE P.O. Box Highway 123 San Marcos, Texas 78666

2 SPECIAL DESIGN CONSIDERATIONS & RECOMMENDATIONS 1. The elevation of the equipment room floor should be at least 18 below the static water level of the reservoir. 2. A sloped floor and 3 gravity floor drain or sump pump system must be provided in the equipment room as well as a 2 waste line for the pumped filter backwash discharge. 3. There should be forced air ventilation in the equipment room with a 300 CFM minimum vent fan. 4. Locate the wind speed sensor (CWS-075) in an area that is subject to the same wind conditions as the fountain and is beyond the reach of human interference. 5. Pipe runs shall be made as direct as possible using the minimum number of fittings. The pipe should slope to the pump for drainage and shall be free of traps or loops that could trap water or air. 6. If pipe slope to the pump is not possible, make provisions for complete draining of each pipe with an accessible valve at the lowest point. 7. There should be a minimum of a 2% slope for the gravity flow piping from the fountain drain fittings to the reservoir. 8. System design reflects the installation of the equipment vault/reservoir within 130 feet of piping distance from the discharge/drain fittings. 9. Fountain People will design all systems and equipment packages to conform to National Electrical Codes and to relevant Uniform Building Code requirements. We are not responsible for conformance to added or differing state or local codes unless we have been made aware of those specific requirements by the client or his agent prior to design development. PERFORMANCE GUARANTEE Fountain People shall guarantee the performance of the fountain design to produce the specified water effects provided all equipment is purchased and installed per our recommendations and all of the architectural details we provide are incorporated into the fountain installation. In the event that others have provided the system design or our recommendations are not utilized, guarantee shall be limited to the performance of the furnished equipment only. PRODUCT WARRANTY Fountain People shall warrant all properly installed and maintained equipment (except lamps) for a period of one year from date of original shipment. For systems with a factory start-up, the warranty shall extend 18 months from date of original shipment or one year from date of start-up, whichever comes first. Fountain People, at their option, shall replace or repair any materials, components, or workmanship found to be defective within the warranty period when returned to the factory, freight pre-paid. No component may be returned to Fountain People for repair or replacement without an approved return materials authorization. This warranty does not include damage resulting from lightning, vandalism, improper maintenance, chemical imbalance, operator error, or other conditions beyond the control of Fountain People, nor labor, freight charges, or incidental materials required to facilitate fountain repairs. Fountain People shall not be held liable for damage to other equipment or materials, loss of time, profits, or any inconvenience directly or indirectly resulting from the failure of equipment or materials furnished by Fountain People. This warranty may exclude damage to metals resulting from chemical control devices that use electrolysis as a means for generating chlorine or other chemicals to treat water. No other warranty, expressed or implied, including the warranties of merchantability exists beyond that included in this statement.

3 Design Concept: The visual effects for this water feature will consist of a dry deck type fountain with a centrally located Fountain-In-A-Can assembly containing a Geyser Nozzle that has an effect height up to 8 feet. Surrounding this effect will be (16) Fountain-In-A-Can assemblies each with a 1 Dominator Nozzle having effect heights up to 6 feet. The nozzles, as a complete group, will raise and lower via a variable frequency drive. The nozzles will be illuminated from below with RGB LED lights for night viewing. Notes: 1. For the LED lights there are (3) zones with up to 8 lights per zone. Each zone will be the same color as selected on the color wheel. The architect is to provide which lights are in each zone. See the plan view drawing P16375-GA01 for the light designators. 2. The outer perimeter trench, to include drain fittings, is to be provided by the installer. 3. The chemical controller is a BECSys5-OS1GP1LRBX with WIFI and Ethernet connectivity. The configuration and monitoring of system by others. EQUIPMENT LIST: Qty Component Description 1 CPL-4X-P16375 UL Listed electronic controls including NEMA-4X (Rated for outdoor location), power distribution, low voltage LED light circuits; LED Amp, power supplies with DMX Controller for color choice for all lights together; motor starters; functions for time clocks, selector switches, alarm and or status pilots, low pressure protection system, wind speed settings and faults are accessed through a touch screen; labeled terminal strips for field connections. 1 PFF-P16375 Skid Mounted System with: filter pump and strainer; sand filter, backwash discharge; isolation and throttling valves; pressure gauges; vacuum gauge; low pressure switch; BECSys5 chemical controller with WIFI; 2 pole pump disconnect in NEMA-3R enclosure; epoxy coated steel housekeeping pad/base. 1 PFP-P16375 Skid Mounted System with: effect pump and strainer; isolation valves; discharge manifold with throttling and check valves; pressure gauge; vacuum gauge; low pressure switch; variable frequency drive; 3 pole pump disconnect in NEMA-3R enclosure; epoxy coated steel housekeeping pad/base Water Treatment, Chlorinator Erosion Feeder, 7Lb capacity, 1.5"FPT connections. 1 PWA-30 Dual application in-ground or free-standing Liquid Acid Storage Tank with valve assembly and metering pump. Housing is heavy duty FRP with a lockable top lid and separate sealed pump compartment. Unit is supplied pre-wired and assembled with all tubing and connectors with a 30 gallon poly acid drum (meets double wall requirements). Tank is designed for full load and is supplied with a chemical funnel (chemicals by Contractor). 4 FFD-300S 3" Floor Drain w/strainer and Waterstop, Brass 1 CWS-075 Wind Speed Sensor, anemometer with 30' cord 1 FWF-150 R600-5 Series Bob Red Brass Valve Assembly with Rotating Plunger, Stem and Float, 1-1/2" NPT Female Inlet x 1-1/2" NPT Female Outlet, 125 psi Pressure 16 FIC-D100-P16375 Fountain-in-a-Can with 1 Dominator Jet, integral swivel; adjustment valve; 24VDC Annular RGB LED light Fixture; ; Junction Box with potting compound; Stainless Steel Slotted Drain Type Grate w/perimeter Drain, Stainless Steel Housing Assembly w/anchors, Pipe and Conduit connections; Stainless Steel Anchor Bolts with nuts and washers; Anchor Bolt Template; and Concrete Pour Cover. 1 FIC-G1100 Geyser in a Can, Surface Mounted Jet Assembly, stainless steel housing; cast bronze cover with tamper resistant fasteners; 1 1/2" geyser jet; threaded pressure connection; stainless steel anchor bolts with nuts and washers; anchor bolt template; and concrete pour cover. 4 FP158T-24T-N Underwater 7", 12x2W, 24VDC Spot RGB LED Light with 10 Meter Underwater Cable, Stainless Steel Niche and ADA Compliant Rock Guard. 1 JP Flush Cast Bronze 6-3/4" x 6-3/4" Junction Box with (1) 1" Side Power Connection; (4) 3/4" Bottom Light Connections; (4) 3/4 x 1/2" Internal Cord Seal Adapters and Grommets for 18-5 Light Cable. 2 RPC-8882 Potting Compound (Gella-8882) 1 W017F Flush (Flat) Launch Pad, Wired Vibration Activated (Flush Deck Mounted) 1 DESIGN SERVICES Schematic drawing to illustrate piping, wiring and utility connections; Installation details for equipment list items; Specifications 3 OPERATION CD-ROM Operation and Maintenance Manuals MANUALS 1 PERFORMANCE Water Effects Performance Guarantee GUARANTEE 1 PRODUCT One Year Equipment Warranty WARRANTY 2 START-UP SERVICE Two Consecutive days of On-Site Inspection, Assistance and Operations training by factory representative at feature start-up

4

5

6

7

8

9

10

11

12

13

14

15 FWF Series Mechanical Float Valve Brass valve with copper float. Model Number FWF-100 FWF-150 FWF-200 NPT / 2 2 Inches A Dimensions Maximum Flow Rate Centimeters GPM LPM A 51cm 61cm 71cm

16

17

18

19

20

21

22

23

24