Asbestos Inspection Report

Size: px
Start display at page:

Download "Asbestos Inspection Report"

Transcription

1 ECH CONSULTANTS Asbestos Inspection Report 113 E. Pine Street Florence, South Carolina Prepared for: The City of Florence Prepared by: Enga Hair, AHERA Building Inspector License #BI Project Number: August 10, Trade Street Florence, South Carolina

2 ECH CONSULTANTS TABLE OF CONTENTS EXECUTIVE SUMMARY 3 BACKGROUND 4 ASBESTOS FINDINGS 5 CONCLUSIONS 6 PHOTOGRAPHS 7 BULK SAMPLE ANALYSIS SCDHEC INSPECTOR LICENSE 1823 Trade Street Florence, South Carolina

3 ECH CONSULTANTS EXECUTIVE SUMMARY The purpose of this investigation was to conduct a limited visual inspection, sample and analyze suspect asbestos containing materials (ACM) which may be disturbed during the future demolition, to determine if any occupational exposures and/or environmental releases of airborne asbestos may occur. The suspect materials were those identified in the United States Environmental Protection Agency (EPA) manual, Guidance for Controlling Asbestos. The identification of ACM meets compliance standards established the EPA under regulation 40 CFR, Part 61, National Emission Standards for Hazardous Air Pollutants, Asbestos NESHAP Revision, Final Rule. The survey was conducted by licensed inspector Enga Hair - # Bulk samples were recorded on a Chain of Custody and submitted to a Polarized Light Microscopy (PLM) laboratory. Eurofins CEI Labs, Inc, located in Cary, North Carolina, is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for satisfactory compliance with criteria established in Title 15, part 7, Code of Regulations, by the National Institute of Standards and Technology (NIST). The laboratory analysis reports the specific type of asbestos identified (there are six (6) types of asbestos minerals) and the percentage of asbestos present. The EPA defines materials as asbestos containing IF an asbestos content of greater than 1% is detected in a representative sample. The sampling strategy utilized throughout the survey complies with the instructions specified in the EPA Regulation 40 CFR, Part Trade Street Florence, South Carolina

4 ECH CONSULTANTS BACKGROUND The facility at 113 E. Pine Street, Florence, South Carolina, is scheduled for a future demolition. The facility, which consists of multiple bedrooms, two (2) bathrooms, kitchen, dining room, and living room is further described with the following characteristics. Two- Story Wood Siding Building Approximately 1,900 square feet Wooden Windows with No Caulk Wooden Floors, Walls, and Ceilings throughout Approximately 60 square feet of Cream VFC over Yellow VFC in Upstairs Bathroom Approximately 168 square feet of Ceiling Texture in Upstairs Bedroom Approximately 1,100 Square Feet of Shingles on Roof * All Quantities Above are approximate 1823 Trade Street Florence, South Carolina

5 ECH CONSULTANTS ASBESTOS FINDINGS The following Table details the fourteen (14) Bulk Samples taken Sample # Description Classification Condition Potential for Disturbance 1 Ceiling Texture None Detected Good Low Cementitious Material None Detected Good Low 2 Ceiling Texture None Detected Good Low Cementitious Material None Detected Good Low 3 Ceiling Texture None Detected Good Low Cementitious Material None Detected Good Low 4 Shingle None Detected Good Low 5 Shingle None Detected Good Low 6 Shingle None Detected Good Low 7 Shingle None Detected Good Low 8 Shingle None Detected Good Low 9 VFC #1 None Detected Good Low 10 VFC #1 None Detected Good Low Mastic None Detected Good Low 11 VFC #1 None Detected Good Low Mastic None Detected Good Low 12 VFC #2 None Detected Good Low 13 VFC #2 None Detected Good Low 14 VFC #2 None Detected Good Low Please refer to the enclosed Asbestos Analysis for additional information 1823 Trade Street Florence, South Carolina

6 ECH CONSULTANTS CONCLUSIONS The following represents areas that are POSITIVE for Asbestos: Non-Friable: N/A Friable: N/A * No Asbestos Containing Materials identified during this inspection 1823 Trade Street Florence, South Carolina

7 ECH CONSULTANTS PHOTOGRAPHS PHOTOGRAPH 1 PHOTOGRAPH Trade Street Florence, South Carolina

8 ECH CONSULTANTS PHOTOGRAPH 3 PHOTOGRAPH Trade Street Florence, South Carolina

9 ECH CONSULTANTS PHOTOGRAPH 5 PHOTOGRAPH Trade Street Florence, South Carolina

10 ECH CONSULTANTS BULK SAMPLE ANALYSIS 1823 Trade Street Florence, South Carolina

11 August 8, 2018 ECH Consultants 1823 Trade Street Florence, SC CLIENT PROJECT: CEI LAB CODE: 113 E Pine St; Florence SC A Dear Customer: Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on August 7, The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method. Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation. Thank you for your business and we look forward to continuing good relations. If you have any questions, please feel free to call our office at Kind Regards, Tianbao Bai, Ph.D., CIH Laboratory Director 730 SE Maynard Road Cary, NC

12 ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for ECH Consultants CLIENT PROJECT: 113 E Pine St; Florence SC LAB CODE: A TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 REPORT DATE: 08/08/18 TOTAL SAMPLES ANALYZED: 11 # SAMPLES >1% ASBESTOS:

13 Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY PROJECT: 113 E Pine St; Florence SC LAB CODE: A METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 Client ID Layer Lab ID Color Sample Description ASBESTOS % Layer 1 A69412 White,Gray Ceiling Texture None Detected Layer 2 A69412 Gray Cementitious Material None Detected Layer 1 A69413 White,Gray Ceiling Texture None Detected Layer 2 A69413 Gray Cementitious Material None Detected Layer 1 A69414 White,Gray Ceiling Texture None Detected Layer 2 A69414 Gray Cementitious Material None Detected A69415 Gray,Black Shingle None Detected A69416 Gray,Black Shingle None Detected A69417 Gray,Black Shingle None Detected A69418 Gray,Black Shingle None Detected A69419 Sample Submitted for TEM Analysis A69420 Gray Floor Covering None Detected Layer 1 A69421 Gray Floor Covering None Detected Layer 2 A69421 Tan Mastic None Detected A69422 Sample Submitted for TEM Analysis A69423 Yellow,Gray Floor Covering None Detected A69424 Yellow,Gray Floor Covering None Detected A69425 Sample Submitted for TEM Analysis Page 1 of 1

14 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Client: ECH Consultants 1823 Trade Street Florence, SC Lab Code: A Date Received: Date Analyzed: Date Reported: Project: 113 E Pine St; Florence SC ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab ID 1 Layer 1 A69412 Layer 2 A Layer 1 A69413 Layer 2 A Layer 1 A69414 Layer 2 A A69415 Lab Description Ceiling Texture Cementitious Material Ceiling Texture Cementitious Material Ceiling Texture Cementitious Material Shingle Lab Attributes White,Gray Non-fibrous Gray Non-fibrous White,Gray Non-fibrous Gray Non-fibrous White,Gray Non-fibrous Gray Non-fibrous Gray,Black Fibrous NON-ASBESTOS COMPONENTS Fibrous Non-Fibrous 5% 5% 5% 25% Talc Talc Talc Fiberglass 75% 20% 35% 65% 75% 20% 35% 65% 75% 20% 35% 65% 40% 35% Calc Carb Paint Binder Silicates Calc Carb Paint Binder Silicates Calc Carb Paint Binder Silicates Tar Silicates ASBESTOS % None Detected None Detected None Detected None Detected None Detected None Detected None Detected Page 1 of 4

15 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Client: ECH Consultants 1823 Trade Street Florence, SC Lab Code: A Date Received: Date Analyzed: Date Reported: Project: 113 E Pine St; Florence SC ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab ID Lab Description Lab Attributes NON-ASBESTOS COMPONENTS Fibrous Non-Fibrous ASBESTOS % 5 A69416 Shingle Gray,Black Fibrous 25% Fiberglass 40% 35% Tar Silicates None Detected 6 A69417 Shingle Gray,Black Fibrous 25% Fiberglass 40% 35% Tar Silicates None Detected 7 A69418 Shingle Gray,Black Fibrous 25% Fiberglass 40% 35% Tar Silicates None Detected 8 A69419 Sample Submitted for TEM Analysis 9 A69420 Floor Covering Gray Fibrous 10% Fiberglass 50% 40% Vinyl Silicates None Detected 10 Layer 1 A69421 Floor Covering Gray Fibrous 10% Fiberglass 50% 40% Vinyl Silicates None Detected Layer 2 A69421 Mastic Tan Fibrous 10% Fiberglass 90% Mastic None Detected 11 A69422 Sample Submitted for TEM Analysis Page 2 of 4

16 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Client: ECH Consultants 1823 Trade Street Florence, SC Lab Code: A Date Received: Date Analyzed: Date Reported: Project: 113 E Pine St; Florence SC ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab ID Lab Description Lab Attributes NON-ASBESTOS COMPONENTS Fibrous Non-Fibrous ASBESTOS % 12 A69423 Floor Covering Yellow,Gray Fibrous 15% 10% Cellulose Fiberglass 50% 25% Vinyl Silicates None Detected 13 A69424 Floor Covering Yellow,Gray Fibrous 15% 10% Cellulose Fiberglass 50% 25% Vinyl Silicates None Detected 14 A69425 Sample Submitted for TEM Analysis Page 3 of 4

17 LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 REPORTING LIMIT: <1% by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points REGULATORY LIMIT: >1% by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. ANALYST: Taylor B. Metcalf APPROVED BY: Tianbao Bai, Ph.D., CIH Laboratory Director Page 4 of 4

18

19

20 August 9, 2018 ECH Consultants 1823 Trade Street Florence, SC CLIENT PROJECT: 113 E Pine St; Florence SC LAB CODE: T Dear Customer: Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on August 8, The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield Method. Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield method is <1% depending on the processed weight and constituents of the sample. Thank you for your business and we look forward to continuing good relations. If you have any questions, please feel free to call our office at Kind Regards, Tianbao Bai, Ph.D., CIH Laboratory Director 730 SE Maynard Road Cary, NC

21 ASBESTOS ANALYTICAL REPORT By: Transmission Electron Microscopy Prepared for ECH Consultants CLIENT PROJECT: 113 E Pine St; Florence SC LAB CODE: T TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 REPORT DATE: 08/09/18

22 ASBESTOS BULK ANALYSIS By: TRANSMISSION ELECTRON MICROSCOPY Client: ECH Consultants 1823 Trade Street Florence, SC Project: 113 E Pine St; Florence SC Lab Code: T Date Received: Date Analyzed: Date Reported: TEM BULK CHATFIELD / EPA 600 / R93 / 116 Client ID Lab ID Material Description Sample Weight (g) Organic Material % Acid Soluble Material % Acid Insoluble Material % Asbestos % 8 Gray,Black Shingle None T82825 Detected 11 Gray Floor Covering None T82826 Detected 11 Tan Mastic None T82827 Detected 14 Yellow Gray Floor T82828 Covering None Detected Page 1 of 2

23 LEGEND: None METHOD: CHATFIELD & EPA/600/R-93/116 LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%) REGULATORY LIMIT: >1% by weight This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request. Samples were received in acceptable condition unless otherwise noted. ANALYST: Jennifer Turner APPROVED BY: Tianbao Bai, Ph.D., CIH Laboratory Director Page 2 of 2

24

25

26 ECH CONSULTANTS SCDHEC INSPECTOR LICENSE 1823 Trade Street Florence, South Carolina

27 ECH CONSULTANTS 1823 Trade Street Florence, South Carolina

28 ECH CONSULTANTS 1823 Trade Street Florence, South Carolina