EXTERIOR PROGRAMING DOCKS ~MUST BE LESS THAN 1100 SF ~GUEST NW CORNER OF SITE) ~SET BACK 50 FT FROM SHORE. ~MAX.

Size: px
Start display at page:

Download "EXTERIOR PROGRAMING DOCKS ~MUST BE LESS THAN 1100 SF ~GUEST NW CORNER OF SITE) ~SET BACK 50 FT FROM SHORE. ~MAX."

Transcription

1 1

2 2

3 3

4 EXTERIOR PROGRAMING EXTERIOR PROGRAMING INTERIOR PROGRAMING EXTERIOR AMPITHEATER BELL COURTYARD TRAILS DOCKS HOUSING ~SEATING FOR UP TO 120 PEOPLE ~ARCHITECTURALLY SIGNIFICANT ~ADA ACCESSIBLE ~MUST BE LESS THAN 1100 SF ~GUEST NW CORNER OF SITE) ~SET BACK 50 FT FROM SHORE. ~CENTER OF CROSS AXIS ~NATURE TRAILS AT THE EDGE OF ~MAX. 10 WIDE 100 STUDENT HOUSING ROW HOUSES 150 BACK FROM HIGH WATER MARK ~INCORPORATE SIGNAGE ABOUT THE CAMP ~SERVES AS AN OUTDOOR LEARNING CENTER HISTORY AND MISSION OF CAMP ~WATER MANAGED ON SITE ~DRAWS PEOPLE IN WITH EASY FLOW THROUGH ~SOUTHERN EXPOSURE FOR MAX USE IN WINTER ~PERMIABLE SERFACES FOR WATER RETENTION ~LIGHTING WILL COMPLY WITH DARK SKY ORD. DOWN LIGHTING AND FLOOD LIGHTS TO ILLUMINATE THE PATHS PARKING LOTS ~SURROUNDED BY DRAINAGE SWALES AND DITCH ~PLANTED WITH NATIVE GRASSES AND SOME WETLAND VEGETATION FOR ONSITE WATER RETENTION ~ALSO SERVES AS SNOW STORAGE AREA FOR THE SPRING MELT ~TOXINS IN SNOW WILL BE FILTERED INTO THE WETLANDS THE PROPERTY SERVE AS LEARNING TOOLS AS WELL AS A FIRE BREAK. ~NATURE TRAILS WILL CONNECT OUTDOOR LEARNING CENTERS. ~WOOD CHIP AND BOARDWALK WILL NOT BE USED AS A BUILDING MATERIAL BECAUSE OF THE HIGH PROBABILTY OF A DEVASTATING FIRE. ~MATIVE ROCK EXCAVATED ON-SITE WILL BE USED TO CREATE THE PATHS. ~CAN BE FLOATING OR STATIONARY ~BOATS CAN DOCK ~CAN EXTEND A MAXIMUM OF 100 FT. FROM THE SHORELINE. ~BUILT WITH CHEMICALLY INERT MATERIALS ~DOCK SERVES AS A LEARNING CENTER ~DOCK CANNOT DISRUPT THE NATURAL SHORELINE ECOLOGY ~POSSIBLE BUILDING MATERIAL TREX DECKING LOCAL WOOD 20 PROFESSIONALS ROW HOUSES FACILITIES ~STAFF N CORNER) ~MAINTENANCE BUILDING W BOARDER 6 STAFF FULL HOUSE (KITCHEN, OF SITE. INCLUDES STORAGE, LAUNDRY, YARD, TWO-THREE BEDROOM AND WOOD SHOP. ~GRADUATES (LOCATED CENTER OF SITE) ~LIVING MACHINE CENTER OF SITE 16 GRADUATES QUADPLEXES ~PUBLIC RESTROOMS AND SHOWERS LOCATED NEXT TO LIVING MACHINE ~YURTS MOBILE CLASSROOMS THAT CAN BE AUDITORIUM BUILDING RELOCATED THROUGHOUT THE SITE. USED ~THREE-STORY MIXED USE BUILDING FOR MEETINGS AND CLASS SESSIONS. CAN ~AUDITORIUM SEATS MAXIMUM OF 250 PEOPLE BE USED FOR TEMPORARY HOUSING ALSO. ~DINING HALL 250 PEOPLE MAX ~FACULTY OFFICES 6 STAFF ~COMPUTER LAB 20 PEOPLE ~SMALL CLASSROOMS Master Plan 4

5 Design Strategies Alternate transportation Onsite water retention Design Strategies Pathway system limits soil compaction and degradation Visual and physical connections to lake Building Analysis Design Strategies Native Rock and recycled onsite lumber for building material. Design supports existing historic site features Minimal removal of old growth ponderosa pine Design Strategies Recreation area accommodate a variety of activities for different age groups. Sustainable strategies Natural Lighting Natural Ventilation Photovoltaic Power Generator Water Purification Food Development Square Footage Living Machine= 3900sf Conservatory = 450sf each Total Package Site Layout Geodesic structure with 4 purification tanks, 1 freshwater tank. 3 separate structures for conservatories and lab spaces. Main sewer line leads to solid waste holding tank where a solar powered pump leads it to the first purification tank. From there it is gravity fed from channels that connect each purification tank finally ending up in a freshwater storage tank where it is returned to the buildings on campus. Total Package Longitudinal Section Daylight 100% exterior air (HVAC) Rammed earth Views Multi-Use facility 5

6 Student housing includes natural light and ventilation as it sits on a north to south axis taking in southern exposure and harnessing views of the lake to the north. The row house setup allows for simple construction, Clustering of major appliances and plumbing, large atrium spaces, and the possibility for additions. Square Footage Sustainable Strategies Natural Lighting Single unit = 375sf Natural Ventilation Row house unit (4)=1500sf Rammed Earth Construction Storm Water Cisterns Student & Guest Housing Photovoltaic Systems Staff housing includes elements such as natural lighting and ventilation in its own community setting. The historical building is being retained for a rental shop and lodge area. Schematic Sketches Square Footage Sustainable Strategies Natural Lighting 1 unit house= 650sf Natural Ventilation Total 4 units = 2600sf Rammed Earth, Hay bail Construction Possible Rooftop Gardens Staff Housing 6