1 Replacement Parts List No Revision M 10/2013 McQuay AAF Enersaver Packaged Terminal Air Conditioner ENC 000 Vintage B ENR Vintage B PNES, PREN Design A(1) & B(2) To find your Daikin Applied parts distributor, call or visit

2 Contents About the Model Changes...2 Parts List Revision History...3, 4 Nomenclature Serial...5 Model - ENC, ENR...6 Model - PNES, PREN...7 Chassis Diagram...8 Components...9 Compressor Section Diagrams...10 Components Condenser (Outside Air) Fan Section...12 Evaporator (Room Air) Fan Section...13 Control Box Diagrams...14 Wall Mounted Thermostats- ENR Only...15 Unit Mounted Thermostats...16 Electric Heat Section...17 Damper Section Manual...18 Motorized- ENR until 11/ Motorized- ENR, PNES 11/97 & later...20 Power Cords...21 Wall Sleeve Cabinet Assembly Diagrams...22 Short Cabinet Components...23 Long Cabinet Components...24 Field Installed Accessories Receptacles...25 Optional Room Cabinet Front Panel...25 Replacement Filter...25 Outdoor Stamped Louvers...25 Condensate Drain Kit...25 Sensor- Wall Mounted...25 Installation Kits and Accessories...26 Hydronic Valves...27 Critical Parts List...CPL1 About the Model Changes In 1999 the model numbering nomenclature for the Enersaver PTAC changed: The ENR "B" Vintage unit is now either the: PNES Design "A" unit (the AAF Enersaver PTAC) or PNES Design"B" unit (the Type 45 retrofit chassis). The unit's components did not change when the nomenclature did (a few engineering changes have taken place since this RPL was last issued, and the part number changes are noted). The complete model number nomenclature currently used has been added to this revision. Unless otherwise noted, all components listed in this revision apply to both the current and the original model numbered units. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 2

3 Parts List Revision History Rev. Date NEW 9/97 A 1/99 Pages 18 & 19 - Corrected description of Ref.# 150 to say "Assy, Wall Sleeve". B 12/99 Page 6 - Added Bubble 8A. Page 7 - Corrected description for Bub. #5 and Bub. #8. Added information for Drain Pan (Bub.#8A). Page 10 - Added Capacitor (Bub. # 38) for size 015,. Page 11 - Added Fan Board (Bub. #8). Corrected description and updated p/n for Motor, (Bub. #57). Corrected Capacitor designation (Bub. #58) for size 015,. Added Motor Mount. Page 13 - Added Receptacle Assy, Plug Assy, Receptacle, Plug, Terminal Pin and Terminal Socket. Page 14 - Updated part number for Freezestat. Page 16 - Added "Before 11/10/97" to title. Page 17 - Added new page 17, "ENR Damper Section - After 11/10/97", re-numbering all pages. C 5/00 Page 9 - Bub #20 Compressor/Rotary 208/230V & Btu's changed to (was Btu). D 5/00 Page 12 - Added arrow for bub #92 to drawing. Page 13 - Delete bub #94 (Knob), added "Remote Only' to bub # 95. Add Escutcheon Plate pn Page 14 - Made note that bub #92 goes with bub #94. Page 20 - Valve, Complete w/wire Harness' voltages were corrected. (not shown on diagram). E 11/00 Page 11- Added bub #57, pn , Motor, 1/12 HP double shaft, size 009,, M1. Deleted size 009 from listing of motor, 1/8 HP, double shaft, M1. F 8/02 Page 18 - Part num (Cord set); qty for size 012 changed to qty. of 1 for & qty. of 0 for. G 3/03 Added nomenclature for PNES Designs A & B. Page 4- Added second page to Parts Revision History. Page 5- Ref # 4 added serial number nomenclature for units built 2/99 and later. Page 7- Added new (subsequent pages are re-numbered). Page 8- Removed ref. # 3, 31, 49. Added ref# 14, 15, 16. Added view of PNES2 baffle and ref # 63. Page 9- Ref # 3 removed. Ref # 1 standard construction added p/n for units built after 7/99. Ref # 4 remove astersisk and note. Ref # 5 added p/n for units built 7/99 & later. Ref # 13 p/n changed to Ref # 14, 15, 16, 63 added. Ref # moved from compressor section. Gasket p/n moved to condenser fan section. Page 10- Removed ref# Page 11- Ref# moved to chassis page. Page 12- Ref # 35 added p/n for size 015. Ref # 38 removed 015 application for and added in its place. Page 13- Ref # 54 added new. Ref # 56 added fan wheel hub clamp. Ref # 57 p/n removed for sizes 012/ added for 012/015. Ref # 62 removed and added 009 usage to Page 15- Added note in headline. Added circuit breakers. Page 16- Added note designating parts used only in ENR. Removed wall sleeve footnotes (did not apply to data on page). Added hydronic heat freezestat. Added terminal board, control box top panel and cover. Added circuit breakers. Page 17- Added columns specific to PNES. separated common parts into separate chart. Page 18- Moved motorized components to next page. Subsequent pages are re-numbered. Added ref # 140, 141 to drawing. Page 19 - Separated motorized damper (pre 11/10/97). Page 20 - Added note regarding usage. Page 21 - Added cords for PNES1 & PNES2. Pages 22 thru 24 - reformatted. Pages 25 thru 27 - added new. H 3/05 Page 9 -Bub #32; 80" cap tube part number change from to continued on next page Daikin Applied, Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN (763) PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 3

4 Parts List Revision History Rev. Date J 1/06 Page 15 - Bubbles #85 & 86: pn change from # to # Bub. #97 Transformer -size 009, pn change from to Transformer - for change from pn to Page 21 - ENR Power Cord (Electric heat only) - 250V Hydronic p/n change from to ; 2.4 kw p/n change from to ; 3.2 kw p/n change from to ; 4.3kW p/n change from to ENR Power Cord (Long Cord) - Wet Heat, 20 amp, p/n change from to ; 20 amp 60" long p/n change from to PNES1 (Design A) Power Cords - Cord Set, Hydronic Heat Units, p/n change from to PNES2 (Design B) Power Cords - Cord Set, Electric Heat Units, p/n change from to K 12/09 Page 13 - Ref #57 change Evaporator Fan Motor p/n from to L 5/12 Rebrand to Daikin Mcquay. Formatted to CS5.5. Page 5- Updated Serial - 2/99 to present. CPL1- Add Critical Parts List. M 10/13 Daikin Rebranding. Add model PREN to title page and nomenclature on pg 7. Drawings were reformatted & numerous changes were done. Page 9- Sheet metal deleted and added footnote1. Added filter p/n Deleted Touch-up Paint p/ns (antique Ivory) & (oxford brown). Page 11- Add new capacitor p/ns , & Page 12- Add new capacitor p/ns , & Page 13- Add new capacitor p/ns & Pages Ref # 138 Filter change to Screen, Fiberglass. Page 22- Delete ENC000B (ordered with ENR "B") PNES1 Field installed Acc.(not used w/des B). Pages Deleted Touch-up Paint p/ns (antique Ivory) & (oxford brown). Page 25- Added Condensate Kits p/ns & Added Sensor p/n & Page 26- Added retrofit kit p/n to Installation Kits from pg 26 Rev L. CPL1- Add PREN to title header and delete ENC. Added Fan Housings ASSY for Evaporator & Condenser. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 4

5 Nomenclature Serial (until 2/99) 7 6A Factory 7 = Auburn, NY Engineering Revision Serial Year and Month of Manufacture: Year Month Z= 1994 A= Jan. 5= 1995 B= Feb. 6= 1996 C= Mar. 7= 1997 D= Apr. 8= 1998 E= May 9= 1999 F= Jun G= Jul H= Aug J= Sep. K= Oct. L= Nov. M= Dec. Serial - 2/99 & later AUB U Plant Identification AUB= Auburn U= Unit Serial (build sequence) Week of Manufacture Year of Manufacture 99= = = 2001 etc. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 5

6 Nomenclature Model - ENC, ENR ENR 009B CC Y UEYM 1 Y Code Unit Type ENR= Enersaver Packaged Terminal Air Conditioner ENC= Wall Sleeve Cabinet Assembly Only 02 Unit Size 009B= Nominal 9000 BTUH Unit 012B= Nominal BTUH Unit 015B= Nominal BTUH Unit 000B= Wall Sleeve Cabinet Only 03 Voltage 11= 115/60/1 39= 240/60/1 03= 208/60/1 40= 277/60/1 YY= No Requirement (Wall Sleeve Cabinet Only) 04 Heater YY= None HH= Hydronic (Hot Water or Steam) 18= 1.8 KW Electric 24= 2.4 KW Electric 32= 3.2 KW Electric 43= 4.3 KW Electric 48= 4.8 KW Electric 05 Chassis Type CC= Commercial SG= SG45 Option Wiring YY= No Requirement (Wall Sleeve Cabinet Only) 06 Not an ENR or ENC Item Y= No Requirement 07 Control Type T-Stat Heat Setback Changeover Location Type Control Type UCYY Unit Cool Only None None UCRY Unit Cool Only Remote None UEYM Unit Elect. None Manual UEYA Unit Elect. None Auto UEUM Unit Elect. Unit Manual UEUA Unit Elect. Unit Auto UERM Unit Elect. Remote Manual UERA Unit Elect. Remote Auto UHYM Unit Hydro. None Manual UHYA Unit Hydro. None Auto UHUM Unit Hydro. Unit Manual UHUA Unit Hydro. Unit Auto UHRM Unit Hydro. Remote Manual UHRA Unit Hydro. Remote Auto WEYM Wall Elect. None Manual WEYA Wall Elect. None Auto WEUM Wall Elect. Unit Manual WEUA Wall Elect. Unit Auto WERM Wall Elect. Remote Manual WERA Wall Elect. Remote Auto WHYM Wall Hydro. None Manual WHYA Wall Hydro. None Auto WHUM Wall Hydro. Unit Manual WHUA Wall Hydro. Unit Auto WHRM Wall Hydro. Remote Manual WHRA Wall Hydro. Remote Auto YYYY No Requirement (Wall Sleeve Cabinet Only) 08 Damper 1= Manual Fresh Air Damper 2= Motorized Fresh Air Damper Y= None (Wall Sleeve Cabinet Only) 25 Miscellaneous X= Special Y= No Requirement PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 6

7 Nomenclature Model - PNES, PREN Code PNES C Z 35 Z 12 AR 14 C I C 1 01 & Unit Type & PNES= Enersaver Packaged Terminal Air Conditioner 02 PREN= Enersaver Packaged Terminal Air Conditioner 03 Unit Design (Vintage) 1= Design A (AAF Enersaver version) 2= Design B (45 replacement chassis) 04 Size (1000's BTUH) Voltage C= 208/60/1 J= 265/277/60/1 06 Coil Options Z= None 07 Heat Options 35= 2.5 KW Electric Heat 41= 3.5 KW Electric Heat 44= 4.0 KW Electric Heat 62= Hydronic Heat w/ Normally Open Valve 63= Hydronic Heat w/ Normally Closed Valve 08 Hand Application Z= Not Applicable 09 Controls 12= Unit Mounted Manual Changeover 24= Unit Mounted MCO + Night Setback (Des. A w/hydronic Heat Only) 10 Discharge AR= Flat Top 11 Return Air/ OA 14= Bottom 12 Power Connection C= Cord 13 Color I= Antique Ivory 14 SKU Type A= Stock B= Standard Leadtime C= Extended Leadtime 15 Product Style 1= 1st Product Style Change PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 7

8 Chassis Diagram See Compressor Section See Condenser Fan Section 35 See Condenser Fan Section 2 9 8A 8 36 See Condenser Fan Section See Compressor Section See Compressor Section PNES2 (Design B) Baffle 63 PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 8

9 Chassis Components Ref Part Unit Size No Panel - End, RH Panel - End, RH, Cold Climate ENR only Panel, End, LH Panel, End, LH, Cold Climate ENR only Blockoff, Evaporator, Front Drain Pan Blockoff, Evaporator Pan, Chassis Bulkhead Bulkhead, Cold Climate ENR only Fanboard/Evap. Motor Mount/Drain Pan Assy A Drain Pan only Blockoff, Evaporator, End RH Blockoff, Evaporator, End LH Gasket, Bulkhead Top Gasket, Evaporator Top Gasket, Condenser Side Gasket Gasket, Baffle Baffle, Condensate Coil, Condenser Coil, Condenser Coil, Condenser Strainer Cap Tube 52" Long Cap Tube 40" Long Cap Tube 80" Long Coil, Evaporator (Room Air) 3 Row Coil, Evaporator (Room Air) 4 Row Baffle, SG45 Chassis PNES2 only N/S Screen, Filter Access N/S Filter, Throwaway until 3/ N/S Filter, Cleanable until 3/ Filter, Cleanable 3/99 & later N/S= Not Shown on Diagram. 1 Please contact Daikin Applied with unit model and serial number for part numbers on Chassis components. 2 Does not apply to the PNES2 (Design B) units. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 9

10 Compressor Section Diagrams Sizes 009, Size 012 Only PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 10

11 Ref. Part No. 20 Compressor Compressor Compressor Compressor Compressor Compressor Compressor N/S Compressor Overload Compressor Overload Compressor Overload Compressor Overload Compressor Overload Compressor Overload Compressor Overload Grommet Sleeve Flange Nut N/S Terminal Cover- Compressor N/S Nut- Compressor N/S Spring- Compressor N/S Gasket- Compressor N/S Gasket- Compressor Capacitor, 25 MFD 370V until 3/ Capacitor, 25 MFD 370V 3/09 & later Capacitor, 20 MFD 370V until 4/ Capacitor, 20 MFD 370V 4/12 & later Capacitor, 25 MFD 440V until 4/ Capacitor, 25 MFD 440V 4/12 & later Cover - Capacitor Bracket - Capacitor Screw N/S= Not Shown on Diagram. * and units apply only to the ENR. 3 Shown on the Chassis Diagram. Compressor Section Components PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 11

12 Condenser (Outside Air) Fan Section Diagram & Components Detail B Ref. Part No. 35 Fan Housing Fan Housing Fan Prop Motor, 1/8 HP Motor, 1/10 HP Motor, 1/10 HP Motor, 1/6 HP Motor, 1/6 HP Motor, 1/6 HP Motor, 1/6 HP Capacitor, 3 MFD 370V until 3/ Capacitor, 3 MFD 370V 3/09 & later Capacitor, 4 MFD 370V until 6/ Capacitor, 4 MFD 370V 6/09 & later Capacitor, 4 MFD 440V until 4/ Capacitor, 4 MFD 440V 4/12 & later Cover, Capacitor, Std Bracket, Capacitor Screw Motor Mount Spacer Grommet, Tube Grommet, Washer Nut * and units apply only to the ENR. 3 Shown on the Chassis Diagram. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 12

13 Evaporator (Room Air) Fan Section Diagram & Components Day Stat (REF. Unit Mounted Thermostat Cap Tube) Ref. Part No. 8 Fan Board Gasket- Fan Board Fan Housing Fan Housing Fan Wheel N/S Clamp- Wheel Hub Motor 1/12 HP Motor 1/12 HP Motor 1/12 HP Motor 1/8 HP Motor 1/8 HP Capacitor, 5 MFD 370V until 4/ Capacitor, 5 MFD 370V 4/12 & later Capacitor, 4 MFD 370V until 4/ Capacitor, 4 MFD 370V 4/12 & later Bracket, Cover-Capacitor Screw Clamp-Motor Mounting N/S Motor Mount Coil- Evaporator (Room Air) 3 Row, 3/8" Tube Coil- Evaporator (Room Air) 4 Row, 3/8" Tube N/S= Not Shown on diagram. * and units apply only to the ENR. 3 Shown on the Chassis Diagram. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 13

14 Control Box Diagrams PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 14

15 Control Box Wall Mounted Thermostats- ENR Only Components Ref. Part No. 85 Relay-Cool R Relay-Heat, Wet Heat R Relay-Heat, Electric Heat R Relay-Fan R Relay-Setback R Relay-Setback R Relay-Remote Setback TDR Switch-Push Button (3) PB Thermostat-Manual Changeover TH Thermostat-Man.Changeover+Fan SW TH Thermostat-Auto Changeover TH N/S Subbase-Auto Changeover Stat Thermostat-Setback TH Thermostat-Low Limit, Remote Only TH Transformer X Transformer X Transformer X Circuit Breaker 15 Amp Circuit Breaker 20 Amp Circuit Breaker 15 Amp Circuit Breaker 20 Amp Circuit Breaker 30 Amp N/S Thermostat-Low Ambient TH N/S Escutcheon Plate N/S Receptacle Assembly N/S Plug Assembly N/S Receptacle N/S Plug N/S Terminal Pin N/S Terminal Socket N/S= Not Shown on diagram. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 15

16 Control Box Unit Mounted Thermostats Components Ref. Part No. 88 Relay, Setback 4 R Relay, Setback 4 R Relay, Remote Setback, Wet Heat 4 TDR Relay, Remote Setback Cool 4 TDR Relay, Remote Setback Elec. Heat 4 TDR Switch, Push Button,(5) Man. Changeover PB Switch, Push Button, (3) Auto Changeover 4 PB Thermostat, Manual Changeover TH Thermostat, Auto Changeover 4 TH Thermostat, Setback TH Knob- Changeover Thermostat N/S Thermostat, Low Ambient TH Circuit Breaker 4 15 Amp Circuit Breaker 4 20 Amp Circuit Breaker 4 15 Amp Circuit Breaker 4 20 Amp Circuit Breaker 4 30 Amp N/S Terminal Board Electric Heat Units Hydronic Heat Units N/S Freezestat- Electric Heat Units TC N/S Freezestat- Hydronic Heat Units TC N/S Panel- Control Box Top N/S Panel- Control Box Cover N/S= Not shown on diagram. * and units apply only to the ENR. 4 Used only on ENR units. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 16

17 Electric Heat Section Diagram & Components or 123 Fan Board Common Parts Ref. Part Qty. No. 121 Clamp-Element Mount-Heater Right-Hand Mount-Heater Left-Hand Wire Harness Overheat Stat-Disc+150F OH Heaters Volt. Ref. ENR PNES Heater Part No. Code 04= Code 07= Position N/A Both Right-hand Left-hand Right-hand Left-hand Right-hand Left-hand N/A Both N/A Both N/A Both N/A Right-hand N/A Left-hand N/A Right-hand N/A Left-hand N/A Both Both Both Right-hand Left-hand N/A= Not applicable. * units apply only to the ENR. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 17

18 Damper Section- Manual Diagram & Components Ref. Part Qty. No. 130 Damper Lever, Damper Operator Angle, Lever Screen, Fiberglass Gasket Gasket N/S Tap Screw N/S= Not shown on diagram. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 18

19 Damper Section- Motorized ENR- until 11/97 Diagram & Components Ref. Part No. 133 Damper Shaft, Damper Spring, Damper Toggle Switch, SPST SW Motor Motor Motor Screen, Fiberglass PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 19

20 Damper Section- Motorized ENR/PNES- 11/97 & later Diagram & Components 9 8 Detail A Detail A 24 1 Detail B Detail B Ref. Part No. 1 Support, Damper Motor Damper Lever Channel Operating Arm Spring Nut Spring, Extension Screw, Tap, 8-18 x Washer Damper Gasket Gasket Screen, Fiberglass Bushing, Snap-in Motor Motor Motor N/S Switch, Rocker, SPDT N/S= Not shown on diagram. * and units apply only to the ENR. PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 20

21 Power Cords Components ENR Power Cords for Building Receptacles Installed by Others- Electric Heat Only Part Cord Set, 250V - Hydronic Cord Set, 125V - UCYY, UCRY Cord Set, (2.4 kw) 15 amp, 60" Lg Cord Set, (3.2 kw) 20 amp, 60" Lg Cord Set, (4.3/4.8 kw) 30 amp, 60" Lg ENR Power Cords Permanently Connected to AAF Wall Sleeve- Short Cabinet Part Cord Set, 20 amp, 20" Lg Cord Set, 20 amp, 20" Lg Receptacle, 20 amp Receptacle, 20 amp ENR Power Cords Permanently Connected to AAF Wall Sleeve- Long Cabinet Part Cord Set, Wet Heat, 20 amp Cord Set, 20 amp, 60" Lg Cord Set, (2.4 kw) 15 amp, 60" Lg Receptacle, 20 amp Receptacle, 20 amp Receptacle, 20 amp PNES1 (Design A) Power Cords Part Cord Set- Electric Heat Units Cord Set- Electric Heat Units Cord Set- Hydronic Heat Units Cord Set- Hydronic Heat Units PNES2 (Design B) Power Cords Part Cord Set- Electric Heat Units Cord Set- Electric Heat Units Cord Set- Hydronic Heat Units Cord Set- Hydronic Heat Units PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 21

22 Wall Sleeve Cabinet Assembly Diagrams 165 Short Cabinet- 37.5" Long (Electric Heat Units) Long Cabinet " Long (Hydronic Heat Units) PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 22

23 Wall Sleeve Cabinet Assembly Ref. Part Qty. No. 150 Wall Sleeve Assembly- Short Cabinet Standard Sea Coast ENR Only Cold Climate ENR Only Access Door Standard Construction Sea Coast ENR Only Access Door w/ Lock Standard Construction ENR Only Sea Coast ENR Only Lock and Keys Only ENR Only Clip - Hinge Hinge Pin Junction Box ENR Only 4EQB Cover-Junction Box ENR Only Gasket Gasket Bracket-Chassis Support Nut until 5/ Nut 5/99 & later Discharge Grille N/S Subbase- 5" N/S Front Panel-Solid Standard Sea Coast ENR Only Cold Climate ENR Only N/S Front Panel-Louver N/S Screw-Front Panel N/S Exterior Louver Stamped ENR Only Extruded N/S= Not shown on diagram. 5 Spotwelded into wall sleeve assembly. Short Cabinet Components PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 23

24 Wall Sleeve Cabinet Assembly Ref. Part Qty. No. 150 Wall Sleeve Assembly- Long Cabinet Standard- Hydronic Heat Sea Coast- Hydronic Heat ENR Only Cold Climate- Hydronic Heat ENR Only Standard- Electric Heat ENR Only Sea Coast ENR Only Cold Climate ENR Only Blockoff- Hydronic Coil Hydronic Heat Coil YRF26A Screw- Hydronic Coil Access Door Standard Construction Sea Coast ENR Only Access Door w/ Lock Standard Construction ENR Only Sea Coast ENR Only Lock and Keys Only ENR Only Clip - Hinge Hinge Pin Junction Box ENR Only 4EQB Cover-Junction Box ENR Only Gasket Gasket Bracket-Chassis Support Nut until 5/ Nut 5/99 & later Discharge Grille N/S Subbase- 5" N/S Front Panel-Solid Standard Sea Coast ENR Only Cold Climate ENR Only N/S Front Panel-Louvered Standard Only ENR Only N/S Screw-Front Panel N/S Exterior Louvered Stamped ENR Only Extruded N/S= Not shown on diagram. 5 Spotwelded into wall sleeve assembly. Long Cabinet Components PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 24

25 Field Installed Accessories Receptacles (field installed in short cabinet subbase or long cabinet end compartment) Part Receptacle- 20 Amp- Units Receptacle- 20 Amp- 265V Units Optional Room Cabinet Front Panel (used when unit is floor mounted WITHOUT electrical subbase) Part Louvered Front Panel Short Cabinet Long Cabinet Angle, Blockoff- either size Gasket- either size Replacement Filter Part Filter, Permanent- Cleanable 30.38" x 7.06" x.25" Outdoor Stamped Louvers (clear anodized aluminum flanged to cover oversized outdoor opening) Part Short Cabinet Long Cabinet Condensate Drain Kit Part Tube Drain Kit for Heat Pumps 1 Pack Tube Drain Kit for Heat Pumps 10 Pack Sensor- Wall Mounted Part TStat- AC/DC, ACO, 7-Day Programmable, 2 Heat/2 Cool Remote Sensor for TSat PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 25

26 Field Installed Accessories Installation Kits and Accessories Part Deflector- Discharge Air Front Panel- Louvered Short Cabinet Long Cabinet Intake Collar- 1½" Outdoor Short Cabinet Long Cabinet Intake Collar- 4½" Outdoor Short Cabinet Long Cabinet Wall Guard Flange- 3 Sided, Indoor Short Cabinet Long Cabinet Thermostat Limiter Retrofit Kit for Type SG45 PNES2 only PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 26

27 Field Installed Accessories Hydronic Valves- ENR Units Part Valve w/harness Valve w/harness Valve w/harness 230V Valve w/harness Hydronic Valves- PNES1 (Design A) Units Part Normally Open 2 Way Valve w/actuator until 4/00 Assembly Assembly Assembly Normally Open 2 Way Valve 4/00 & later Valve Body Actuator Actuator Actuator Hydronic Valves- PNES2 (Design B) Units Part Normally Closed 3 Way Valve w/actuator until 4/00 Assembly Assembly Assembly Normally Closed 3 Way Valve 4/00 & later Valve Body Actuator Actuator Actuator PTAC; ENC 000 Vint. B / ENR Vint. B / PNES, PREN Des. A & B Rev. M 10/13 RPL / Page 27

28 Critical Daikin Applied OEM Parts Are What Your Daikin Applied HVAC Unit Needs! McQuay Packaged Terminal Heat Pump AAF Packaged Terminal Heat Pump ENR, Unit Sizes , Vintage B PNES, PREN Unit Sizes , Designs A & B CRITICAL COMPONENTS MODEL UNIT SIZE VOLTAGE PART NUMBER COMPRESSOR 9100 BTUH ALL /60/ BTUH ALL /60/ BTUH ALL /60/ BTUH ALL /60/ BTUH ALL /60/ BTUH ALL /60/ BTUH ALL /60/ CONDENSER MOTOR Motor, 1/8 HP ALL /60/ Motor, 1/10 HP ALL /60/ Motor, 1/10 HP ALL /60/ Motor, 1/6 HP ALL /60/ Motor, 1/6 HP ALL /60/ Motor, 1/6 HP ALL /60/ Motor, 1/6 HP ALL /60/ EVAPORATOR MOTOR Motor, 1/12 HP ALL /60/ Motor, 1/12 HP ALL /60/ Motor, 1/12 HP ALL /60/ Motor, 1/8 HP ALL 012, /60/ Motor, 1/8 HP ALL 012, /60/ DAMPER MOTOR Motor ALL ALL 115V Motor ALL ALL 208/230V Motor ALL ALL 265V FAN HOUSING ASSY & WHEEL Fan Housing Assy- Condenser ALL 009, 012 N/A Fan Housing Assy- Condenser ALL 015 N/A Fan Prop- Condenser ALL ALL N/A Fan Housing Assy- Evaporator ALL 009 N/A Fan Housing Assy- Evaporator ALL 012, 015 N/A Wheel- Evaporator ALL ALL N/A Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS Rev. M 10/2013 CPL Page 1 of 1