NYC Department of Education

Size: px
Start display at page:

Download "NYC Department of Education"

Transcription

1 NYC Department of Education Architectural Inspection Building Assessment Survey Asset: P.S. 234 ANNEX - MANHATTAN, 200 CHAMBERS STREET, New York, Inspection Id Inspection Type Time In Last Edited SA : Architectural - Senior :37 PM :15 PM AA : Architectural - Associate :58 PM :40 PM Asset Data Was the building fully accessible for inspection Inspection Access Comment Principal(s) Information Custodian Fireman Principal Name Organization Did you meet with this Principal? Did this Principal provide feedback? Summary of Principal's Feedback Answer Senior Architect: Foundation Walls ( Access to Basement), Electrical Engineer: Basement (Service Switch, Switchboard, Em. L. Panel, FAS (Fused Cut Out, Air Pressure Switch, Chain)) Due to no access Lisa Ripperger P.S. 234 Annex - Manhattan The Principal's comment is as follows: The Custodial Staff has no control over the dedicated heating system in the building. Daniel Purtill Building Square Footage 10,300 Comments on the Area Comments on the Stories (Floors) plus Basements 7+B Comments on the Number of Classrooms 7 Was not present ne Comments on the Year Built 2007 Student Population 117 Staff Population 8 Weather Facade Photo Fair Along Warren Street - rthwest View PB/A&W Page 1 of 8

2 Architectural Inspection Main Entrance Photo NYC Department of Education Building Assessment Survey Facade A - Warren Street Roof Photo Have any Systems/Major Building Components been upgraded? Have there been any New Building Additions? Tandem Schools? Leased Space? Year Leased 2008 Inspection Partial Inspection Priority Nil Priority Exist Last Year? Priority Category Description Component Affected Location Description Person(s) tified Person(s) Title PhotoImage condition recorded Structural Engineer Required Structural Type Description Component Affected Location Description Person(s) tified Person(s) Title PhotoImage condition recorded Accessibility Accessibility Status Is the primary or secondary entrance on an accessible route? Is the building a multi-story building? Are all floors of the building accessible through compliant means? Accessible classrooms exists on each floor? Boys and Girls or Unisex accessible toilets exist on at least every other floor? If the following spaces exist, are they ALL accessible? Art Room, Auditorium, Cafeteria, Computer, Gymnasiums, Library, Multipurpose Room, Science Labs Physical Breakdown Structure Exists Complies Required FUNCTIONAL ACCESSIBILITY Exterior Routes Exterior Entrances & Exits Exterior H/C Lifts Exterior Ramps and Railings Interior Routes PB/A&W Page 2 of 8

3 Architectural Inspection NYC Department of Education Building Assessment Survey Physical Breakdown Structure Exists Complies Required Interior Routes Corridor and Lobby H/C Lifts Interior Corridor Doors and Hardware Interior Corridors and Lobbies Interior Elevators Interior Lobby Doors and Hardware Interior Ramps Rooms & Spaces Art Rooms Auditorium Cafeteria Classrooms 3rd, 4th Floor Computer Rooms Gymnasium Library Main Office Room 438 Multi-purpose Room Nurse's Room Room 438A Pool Science Lab Toilet Rooms (Boys) 3rd, 4th Floor Toilet Rooms (Girls) 3rd, 4th Floor Toilet Rooms (Staff) 3rd Floor (Unisex) Building Template Inspection Architectural EXTERIOR PB/A&W Page 3 of 8

4 Architectural Inspection EXTERIOR AREAWAY AWNINGS AND CANOPIES CHIMNEY COPING CORNICE DOORS DOORS AND FRAMES DOOR HARDWARE LINTELS TRANSOM/SIDE LIGHT EXTERIOR WALLS Material Type(s) Steel Replacement Quantity 5,000 Replacement Uom Instance on All Facades Instance Instance Quantity 5,000 Instance Quantity Uom EXTERIOR SOFFITS LOADING DOCK LOUVER PARAPETS PLAZA DECK ROOF Roofing Replacement Quantity 500 Replacement Uom ROOF HATCH/SMOKE HATCH LEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS ROOF BARRIER ROOF CAGE ROOF FENCE ROOFING Instance on IRMA: Roof 2 Instance NYC Department of Education Building Assessment Survey t Required PB/A&W Page 4 of 8

5 Architectural Inspection EXTERIOR ROOF Roofing ROOFING Instance Quantity 500 Instance Quantity Uom Does the roof have major mechanical equipment sitting on Dunnage Steel less than 18" above the Roofing? Installation Year 2007 Source of Installation ROOFING DRAINS Specialties BULKHEAD/PENTHOUSE CUPOLA/ SPIRES/ TOWERS DORMER DUNNAGE STEEL SKYLIGHT/ROOF VENT ROOF/GRAVITY TANK STAIRS/RAMPS: EXTERIOR WINDOWS Custodial Staff t Required t Required t Required Replacement Quantity 3,000 Replacement Uom EXTERIOR GUARDS LINTELS WINDOWS INTERIOR Material Type(s) Instance on Aluminum - Other: All Facades Instance Aluminum Instance Quantity 3,000 Instance Quantity Uom Installation Year 2007 Source of Installation NYC Department of Education Building Assessment Survey Custodial Staff POOLS STRUCTURAL COLUMNS/BEAMS/BEARING WALLS FLOOR STRUCTURE FOUNDATION WALLS ROOF STRUCTURE Inaccessible PB/A&W Page 5 of 8

6 NYC Department of Education Building Assessment Survey Architectural Inspection INTERIOR STRUCTURAL ROOF STRUCTURE VAULTS-BUNKERS AUDITORIUM CAFETERIA CLASSROOMS/CORRIDORS/ADMIN SPACES Ceiling Door(s) Floor Finish Walls Specialties GYMNASIUM INTERIOR DOOR HARDWARE INTERIOR GUARDS KITCHEN LIBRARY LOCKER ROOM MULTI-PURPOSE ROOM SCIENCE DEMO ROOM SCIENCE LAB SCIENCE PREP ROOM SHOWER ROOM STAIRS/RAMPS: INTERIOR Do Letter Stair Signs Exist? Ceiling Door(s) Partition Railings Stairs and Landings PB/A&W Page 6 of 8

7 NYC Department of Education Building Assessment Survey Architectural Inspection INTERIOR STAIRS/RAMPS: INTERIOR Stairs and Landings Walls MASONRY: CRACKS/SPALLING TOILET ROOMS - STAFF Ceiling Door(s) Floor Finish Stalls Walls TOILET ROOMS - STUDENTS Ceiling ACOUSTIC TILES: DAMAGED/MISSING Location/Instance Room 437A Quantity 10 Quantity Uom Potential Action REPLACE Urgency of Action PRIORITY 3 Purpose of Action LEVEL 2 Photo1 Violations Door(s) Floor Finish Stalls Room 437A violations recorded. PB/A&W Page 7 of 8

8 NYC Department of Education Building Assessment Survey Architectural Inspection INTERIOR TOILET ROOMS - STUDENTS Stalls Walls LIFE SAFETY F.D. HOLDING AREA STEEL STAIRS SITE CONTAINERIZATION Drainage System for Asphalt Drainage System for Concrete Drainage System for Soil DRINKING FOUNTAINS FENCES IRRIGATION SYSTEM PAVING Student n-use Student Use Site Sidewalks & Walkways DOT Sidewalk Asphalt Concrete Pavers PLAYGROUNDS PLAYING SURFACE RETAINING WALLS SEATING SITE WALLS (NOT RETAINING WALLS) STAIRS/RAMPS: EXTERIOR PB/A&W Page 8 of 8