1 TESTED - CERTIIED windows & dos BSHIRE RATED SYSTEMS OR BAL-40 ZONES In response to devastating bushfires, Australian Bushfire attack levels (BALS) Standard AS3959 has been updated and republished. AS is primarily concerned with improving the ability of buildings in designated bushfire-prone areas to better withstand attack from bushfire thus giving a measure of protection to the building occupants (until the fire front passes) as well as to the building itself. AWS has developed and tested an extensive range of Vantage, Elevate and ThermalHEART aluminium windows and dos to meet and exceed BCA requirements f compliance under Australian Standard AS f windows and dos in a BAL-40 bushfire zone. These products are engineered, tested and certified to withstand the conditions likely to occur in a BAL-40 zone and are designed to help you protect your home whilst still delivering unprecedented style, efficiency and functionality f your lifestyle. BAL LOW BAL 12.5 BAL 19 BAL 29 BAL 40 BAL Z Insufficient risk to warrant a construction response Concern of ember attack Increasing levels of ember attack and airbne burning debris. Increasing danger from radiant heat up to 19kwm² Greater risk of damage from airbne burning debris. urther risk from radiant heat exposure up to 29kwm² Burning debris ignited by windbne embers and radiant heat exposure up to 40kwm². Likelihood of direct flame contact Direct flame contact from fire front & radiant heat exposure greater than 40kwm²

2 TESTED - CERTIIED windows & dos BSHIRE RATED SYSTEMS OR BAL-40 ZONES AWS COMPLIANT SYSTEMS AWS has developed and tested an extensive range of Vantage, Elevate and ThermalHEART aluminium windows and dos to meet and exceed BCA requirements f compliance under Australian Standard AS f windows and dos in a bushfire zone. The following AWS window systems will comply with these requriements PRODCT IDENTIICATION Throughout AWS brochures, websites and and literature, window and do systems which have been tested certified to comply with AS are identified with the BAL-40 logo illustrated below. Testing undertaken is in accdance with AS and the certification is issued based upon a positive outcome to this testing procedure. TESTED-CERTIIED Series 502, 504, 506 Sliding Window Series 516 Awning Window Series 517 Awning Window Series 542 DStacker Sliding Do Series 549 Entry Do Series 548 rench Dos Series 548 Bi-fold Dos Series 602 Sliding Window Series 616 Awning Window Series 618 Sliding Do Series 726 Awning Window Series 729 Hinged Do Series 730 Bi-fold Do Series 731 Sliding Do Series 50 Commercial Do Series 52 Commercial Do Series 452 Commercial Sliding Window Series 456 Commercial Awning Window Series 461 Apartment Sliding Window Series 471 Apartment Sliding Do Series 410 oldmaster Bi-fold (Bottom rolling) Series 462 Architectural Sliding Window Series 466 Awning Window Series 650 Architectural Hinged Do Series 400 CentreGLAZE SG (102mm) Series 424 CentreGLAZE DG (102mm) Series 624 CentreGLAZE DG (150mm) Series 406 rontglaze SG (102mm) Series 606 rontglaze SG (150mm) Series 426 rontglaze DG (102mm) Series 626 rontglaze DG (150mm) Series 600 Wide Offset (150mm) Series 804 Thermally Broken CentreGLAZE (100mm) Series 806 Thermally Broken CentreGLAZE (150mm) Series 824 Thermally Broken rontglaze (100mm) Series 826 Thermally Broken rontglaze (150mm) Series 852 Thermally Broken Commercial Do PRODCT LABELLING TESTED - CERTIIED All AWS windows supplied as compliant f BAL-40 bushfire zones will be identified with the following adhesive label: This product has been tested - certified to comply with BCA requirements f windows in BAL-40 Bush fire zones. Should this product its components require repair replacement contact ARCHITECTRAL WINDOW SYSTEMS to maintain compliance. techsuppt@awsaustralia.com.au PRODCT SPECIICATION When specifying AWS window and do systems f BAL-40 bushfire applications, please make your fabricat aware of this requirement as specific mohair, seals, hardware and components are required during manufacture to ensure compliance. SCREENS AWS BAL-40 rated systems have been successfully tested to comply with relevant Australian Standards without the use of screens. Any accredited BAL-40 rated screen can be fitted to AWS window systems in accdance with Australian Standard. Approved fire rated screens in accdance with Australian Standard are required on all opening ptions of windows.

3 TESTED - CERTIIED windows & dos BSHIRE RATED SYSTEMS OR BAL-40 ZONES Distance from Vegetation BSHIRE ATTACK LEVELS In the Australian Standard AS3959, they have classified different bushfire intensity levels that a home may experience during a bushfire. These are referred to as Bushfire Attack Levels, BALs f sht. There are six bushfire attack levels in total: BAL-Z lame Zone BAL-40 BAL-29 BAL-19 BAL-12.5 BAL-Low These individual levels are based on: 1. The region where you live. 2 The vegetation type around your property. 3. The distance from your home to individual vegetation types. 4. Slope on the property. B A Effective Slope BAL-40 is currently the highest bushfire attack level where AWS window and do systems can be used. ACTORS AECTING BSHIRE ATTACK LEVEL Bushfire Attack Level BAL is determined by a number of facts: Type of Vegetation Distance from Vegetation Effective Slope ire Danger Index DI B Type of vegetation ire Danger Index A D 40m 30m 20m 10m Tall Open est Tall Woodland 40m Open est Low Open est 15m 4m 30m 10m 20m 2m 5m 10m Open Woodland Open Woodland 2m Low Woodland Low Open Woodland 4m 1m Open Heath Low Shrubland 4m 2m Closed Heath Open Shrubland 2m Closed Scrub Open Scrub Tall Shrubland

4 TESTED - CERTIIED windows & dos BSHIRE RATED SYSTEMS OR BAL-40 ZONES WINDOW AND DOOR REQIREMENTS OR BSHIRE PRONE AREAS WINDOW AND DOOR REQIREMENTS OR BSHIRE-PRONE AREAS BAL-LOW Standard window and do products may be used at this level. There are no special requirements. BAL-12.5 Windows Standard windows must be completely protected by shutters complying with AS clause A tested window system must be used compliant with AS , operable ption of the window must be screened internally externally with metal screens with an aperture of 2mm made from crosion resistant steel, bronze aluminum The following deem-to-satisfy approach can be used All openings must be screened internally externally with metal screens with an aperture of 2mm made from crosion resistant steel, bronze aluminium. Where glazing is less than 400mm from the ground other structures (decks etc) and less than 18 degrees to the hizontal, Grade A safety glass minimum 4mm must be used. If windows incpate glazing within 400mm to the ground, they must be manufactured from: a. Bushfire resistant timber (Appendix ). b. Timber species as listed in Appendix E. c. Metal / Aluminium. d. upvc with reinfced crosion resistant steel. Externally fitted hardware that suppts the sash in its Grade A Glass Grade A Glass min 4mm min 4mm DEEM-TO-SATISY Side-Hung External Dos & Sliding Dos Standard windows must be completely protected by shutters compliant to AS clause A tested do system must be used compliant with operable part of the do The following deem-to-satisfy approach can be used Where glazing is incpated glass shall be Grade A safety in accdance with AS Side-hung dos require draught excluders installed at the sill. Sliding dos to have tight fitting seals. No requirement to screen the operable ption of a sliding do. Where any part of the do assembly is within 400mm to the ground other structures (decks), and less than 18 degrees to the hizontal, do frames must be made from: a. Bushfire resistant timber (Appendix ). b. Timber species as listed in Appendix E. c. Metal / Aluminium. d. upvc with reinfced crosion resistant steel. DEEM-TO-SATISY

5 TESTED - CERTIIED windows & dos BSHIRE RATED SYSTEMS OR BAL-40 ZONES BAL-19 WINDOWS Standard windows must be completely protected by shutters complying with AS clause A tested window system must be used compliant with AS , operable ption of the window must be screened internally externally with metal screens with an aperture of 2mm made from crosion resistant steel, bronze aluminum The following deem-to-satisfy approach can be used Where annealed glass is used, fixed and operable ptions must be screened. Where toughened glass is used minimum is 5mm and openings must be screened internally externally made from crosion resistant steel, bronze aluminium. Where glazing is less than 400mm from the ground other structures (decks etc) and less than 18 degrees to the hizontal and me than 110mm in width, 5mm toughened glass must be used. Externally fitted hardware that suppts the sash in its If window assemblies are within 400mm to the ground, they must be manufactured from: a. Bushfire resistant timber (Appendix ). b. Timber species as listed in Appendix E. c. Metal / Aluminium. d. upvc with reinfced crosion resistant steel. Annealed Glass Annealed Glass Annealed Glass Annealed Glass Side-hung external dos & Sliding dos A tested do system must be used compliant with operable part of the do Where dos incpate glazing, the glass must be toughened 5mm minimum. Where any part of the do assembly is within 400mm to the ground other structures (decks) and less than 18 degrees to the hizontal, do frames must be manufactured from: a. Bushfire resistant timber (Appendix ). b. Timber species as listed in Appendix E. c. Metal / Aluminium. d. upvc with reinfced crosion resistant steel. Side-hung dos require draught excluders installed at the sill. Sliding dos to have tight fitting seals. No requirement to screen the operable ption of a sliding do. DEEM-TO-SATISY DEEM-TO-SATISY DEEM-TO-SATISY Standard windows must be completely protected by shutters complying with AS clause 3.7 The following deem-to-satisfy approach can be used

6 TESTED - CERTIIED windows & dos BSHIRE RATED SYSTEMS OR BAL-40 ZONES BAL-29 Windows Standard windows must be completely protected by shutters complying with AS clause A tested window system must be used compliant with AS , operable ption of the window must be screened internally externally with metal screens with an aperture of 2mm made from crosion resistant steel, bronze aluminum The following deem-to-satisfy approach can be used Window assemblies must be manufactured from: a. Bushfire resistant timber (Appendix ). b. Metal / Aluminium. c. upvc with reinfced crosion resistant steel. Glazing must be a minimum of 5mm toughened glass. Where glazing is less than 400mm from the ground other structures (decks etc) and less than 18 degrees to the hizontal extending me than 110mm in width, that ption must be screened. Externally fitted hardware that suppts the sash in its The operable ption and low light area must be screened with a mesh with a maximum aperture of 2mm, made from a crosion resistant steel, bronze aluminium. Side-hung external dos Standard windows must be completely protected by shutters complying with AS clause A tested do system must be used compliant with operable part of the do The following deem-to-satisfy approach can be used Where dos incpate glazing, the glass must be toughened 6mm minimum. Externally fitted hardware that suppts the panel in its Where any part of the do assembly is within 400mm to the ground other structures (decks) and less than 18 degrees to the hizontal and extending me than 110mm in width, that area must be screened covered with a perfated sheet. Do frames must be made from: a. Bushfire resistant timber (Appendix ) b. Metal / Aluminium. c. upvc with reinfced crosion resistant steel. Side-hung dos require draught excluders installed at sill. Sliding dos DEEM-TO-SATISY DEEM-TO-SATISY Standard windows must be completely protected by shutters complying with AS clause completely screened with a mesh having an aperture of 2mm, made from crosion resistant steel, bronze aluminium. A tested do system must be used compliant with operable part of the do. The following deem-to-satisfy approach can be used Where dos incpate glazing, the glass must be toughened 6mm minimum. With 6mm toughened glass, screening is not required. Externally fitted hardware that suppts the panel in its Do frames must be made from: a. Bushfire resistant timber (Appendix ) b. Metal / Aluminium. Sliding dos shall be tight fitting in frames DEEM-TO-SATISY

7 TESTED - CERTIIED BAL-40 Windows Standard windows must be completely protected by shutters complying with AS clause A tested window system must be used compliant with AS , operable ption of the window must be screened internally externally with metal screens with an aperture of 2mm made from crosion resistant steel bronze. The following deem-to-satisfy approach can be used Window frames and hardware shall be metal (includes aluminium) Glazing must be a minimum of 6mm toughened glass. Both the operable and fixed ptions must be screened with a mesh with a maximum aperture of 2mm, made from a crosion resistant steel bronze. Seals to stiles, head and sills shall be manufactured from materials with a flammability index no greater than 5 made from silicone. DEEM-TO-SATISY BAL-40 Side-hung external dos Standard windows must be completely protected by shutters complying with AS clause A tested do system must be used compliant with operable part of the do The following deem-to-satisfy approach can be used Dos shall be made from a non-combustible, timber. Dos to be a minimum thickness of 35mm Where dos incpate glazing, the glass must be toughened 6mm minimum. Externally fitted hardware that suppts the panel in its Where any part of the do assembly is within 400mm to the ground other structures (decks) and less than 18 degrees to the hizontal and extending me than 110mm in width, that area must be screened/covered with a perfated sheet. Seals to stiles, head and sills shall be manufactured from materials with a flammability index no greater than 5 made from silicone. Side-hung dos require draught excluders installed at sill. DEEM-TO-SATISY BAL-40 Sliding dos Standard windows must be completely protected by shutters complying with AS clause A tested do system must be used compliant with operable part of the do The following deem-to-satisfy approach can be used Where dos incpate glazing, the glass must be toughened 6mm minimum. With 6mm toughened glass, screening is still required to both operable and fixed ptions. Externally fitted hardware that suppts the panel in its Seals to stiles, head and sills shall be manufactured from materials with a flammability index no greater than 5 made from silicon Sliding dos shall be tight fitting in frames. DEEM-TO-SATISY windows & dos BSHIRE RATED SYSTEMS OR BAL-40 ZONES

8 TESTED - CERTIIED windows & dos BSHIRE RATED SYSTEMS OR BAL-40 ZONES BAL-Z Where fitted, bushfire shutters shall comply with AS Windows shall be completely protected by bushfire shutters have an RL of -/30/- comply with AS Side-hung dos shall be completely protected by bushfire shutters have an RL of -/30/- comply with AS Sliding dos shall be completely protected by bushfire shutters have an RL of -/30/- comply with AS