Copyrighted Home Plan 2011 Natural Element Homes, LLC

Size: px
Start display at page:

Download "Copyrighted Home Plan 2011 Natural Element Homes, LLC"

Transcription

1

2 64'-0" DECK 24'-0" 13'-10" 10'-2" 8'-0" 7'-6" WALK-IN '-10 1/2" 4'-2 1/2" '-5" 2'-6" 1832-T FRENCH FRENCH 6" PLUMBING WALL BENCH 4-2X4 POST W/ SCREW JACK ASSEMBLY (TYP.) MASTER BEDROOM 5'-10" '-2" BATH '-10" LINEN 31'-0" 11'-0" 22'-0" 3'-4" /8" 13 10" 2'-1 1/2" LITE '-0" 6'-4" PORCH CONVENTIONAL STAIRS MAIN FLOOR PLAN GREAT ROOM 13'-4 1/2" 3'-3 1/2" 14'-4" 7'-3 1/2" 8'-3" 8'-2" 7'-3 1/2" 24'-0" 8'-0" 1'-6" 2'-6" 5'-7" 5'-5" 22'-0" 10'-0" DW KITCHEN 11'-6" BREAKFAST AREA 11'-1/8" '-0" HALF BATH 3'-11" 5'-1" 5'- 1/2" 6'-6 1/4" '-6" FIRE RATED UTILITY ' GARAGE DOOR DOOR & HEADER BY OWNER 21'-10" TWO-CAR GARAGE STORAGE 24'-8" '-0" ' GARAGE DOOR DOOR & HEADER BY OWNER '-0" 16'-0" 34'-0" HEATED AREAS: FIRST FLOOR SECOND FLOOR HEATED TOTAL UNHEATED AREAS: SQUARE FOOTAGE DECK/PORCH AREA RESPONSIBILITY OF THE BUILDER/OWNER THESE DRAWINGS ARE IN PART DIAGRAMMATIC AND DO NOT SHOW IN DETAIL HOW WORKMANSHIP, MATERIALS AND INSTALLATION OF THE MATERIALS INCLUDING THE FIXTURES AND EQUIPMENT ARE TO BE BROUGHT TOGETHER TO COMPLETE THE "WHOLE" STRUCTURE. IT IS THE RESPONSIBILITY OF THE BUILDER/OWNER TO BUILD THE STRUCTURE TO COMPLY WITH ALL APPLICABLE NATIONAL, STATE, COUNTY AND CITY CODES AS THEY APPLY TO EACH COMPONENT BUILDING GREEN: 1) WHERE POSSIBLE, USE COMPACT FLUORESCENT LIGHTING. 2) USE DURABLE ROOF COVERINGS SUCH AS STEEL OR FIBER CEMENT TO REDUCE THE NECESSITY FOR FUTURE ROOF COVERING REPLACEMENTS. 3) THE USE OF FACTORY BUILT COMPONENTS REDUCES THE AMOUNT OF JOB SITE CUTTING FURTHER REDUCING WASTE. 4) CHOOSE ENERGY STAR RATED APPLIANCES WHENEVER POSSIBLE. 5) USE NATIVE PLANTS DURING LANDSCAPING TO REDUCE THE NEED FOR WATERING AND FERTILIZING. 6) IN ROOF SYSTEMS AND EXTERIOR STUD WALLS, USE THE HIGHEST R-VALUE POSSIBLE. 7) USE LOW-E WINDOWS TO REDUCE HEAT TRANSFER KINGSWOOD WINDOWS FIBERGLASS DOORS CAUTION MUST BE EXERCISED IN MAKING ANY CHANGES IN THIS PLAN. MINOR CHANGES IN ONE AREA OF THE HOUSE COULD LEAD TO MAJOR PROBLEMS IN ANOTHER AREA. KIM BATTY 2X4X8'-1 1/8" LAMBERT 10/07/10-MESB 10/1/10-MESB

3 SHED DORMER 31'-0" 13'-3/4" 15'-1/4" 2'-11" 1832-T '-10 1/2" '-6" 5'-6 WALK-IN 7'-6" '-2" 11'-0" 14" LVL RIDGE BEAM BEDROOM x4s TO SUPPORT RIDGE BEAM (TYP.) APP. 5' HEAD CLEARANCE 3'-3 3/4" BATH 3'-3 1/2" /8" 13 10" 2'-4" 4'-1 3/4" 5'-3 1/2" x4s TO SUPPORT RIDGE BEAM (TYP.) BEDROOM 5'-3 1/2" 8'-8 1/2" '- 1/4" OPEN TO AREA BELOW 3-1 3/4" x 14" LVL RIDGE BEAM GARAGE AREA BELOW TABLE R CRICKET DIMENSIONS ROOF SLOPE / 8/ 6/ 4/ 3/ H 1/2 OF W 1/3 OF W 1/4 OF W 1/6 OF W 1/8 OF W 4'-7 1/2" 4'-8" 11'-" 4'-8" SECOND FLOOR PLAN

4 FINISHED ROOFING (BY OWNER) CONTINUOUS RIDGE VENT (BY OWNER) 1x WP & 1x4 STEPPED RAILING BY OWNER STEPS TO GRADE PER SITE CONDITIONS BY OWNER FRONT ELEVATION

5 x WP & 1x4 STEPPED 1x6 WP EXTERIOR WINDOW AND DOOR TRIM (TYP.) 3 RAILING BY OWNER 4x8 DF PORCH PLATE 6x6 DF PORCH POST LEFT ELEVATION

6 CRICKET SUPPLIED BY OTHERS - SEE TABLE R FOR SIZING CONTINUOUS RIDGE VENT (BY OWNER) 1x WP & 1x4 STEPPED FINISHED ROOFING (BY OWNER) INSTALL FLASHING BEFORE APPLYING FINISHED ROOFING (BY OWNER) REAR ELEVATION

7 1x WP & 1x4 STEPPED 3.5 FINISHED ROOFING (BY OWNER) RIGHT ELEVATION