Insulation manufacturer to submit dew point analysis free of charge for typical wall section. Analysis by:

Size: px
Start display at page:

Download "Insulation manufacturer to submit dew point analysis free of charge for typical wall section. Analysis by:"

Transcription

1 PACE REPRESENTATIVES INC. 50 Redfield Street Boston MA PRE JOB AIR BARRIER/EXTERIOR WALL INSULATION MEETING CHECK LIST 1.01 Date: Insulation manufacturer to submit dew point analysis free of charge for typical wall section. Analysis by: Suggested Attendees: Owner Rep: Architect: GC: Air Barrier Manufacturer: Air Barrier Contractor: Insulation Contractor: Roofing Contractor: Window Contractor: Mason Contractor: Waterproofing Contractor: Drywall Contractor Metal Panel Contractor - Trades That Tie Into Or Penetrate The Air Barrier 1) 2) 3) Air Barrier Systems Sheet membrane 40mil Carlisle CCW 705 Liquid Carlisle Barriseal spray grade Liquid Carlisle Barriseal roll grade Dens-Glass taped joints CCW 705 Protean Metal Panel

2 Substrate For Air Barrier Air Barrier Primer Dens-Glass Block Precast Metal Panel Protean Metal Panel Substrate Preparation Note that open substrate joints can cause air barrier failure at the seams due to negative and positive pressures on the wall assembly. Care should be taken in closing all joints. Substrate Dens-Glass Block (should be free of voids) Concrete Contractor Responsible Over Spray Protection Of Sprayed Air Barrier Protection of other areas of the building being sprayed Protect adjacent buildings Protect cars and equipment etc. Contractor Responsible Temperature Considerations Air Barrier Carlisle CCW 705 Carlisle Barriseal Temperature Range Contractor Responsible:

3 Air Barrier Protection Contractor Responsible Best practice is to protect the air barrier from construction damage and UV rays as soon as possible. Extruded polystyrene can be attached over the air barrier by a temporary spray adhesive or permanent mechanical fastener. On brick veneer, Heckmann Posi-Ties will become the permanent fastener for the insulation and brick. However, temporary attachment of the insulation until that time is a good idea. Air Barrier Adhesive Mechanical Fastener Carlisle CCW 705 CCW Cav-Grip Carlisle Barriseal CCW Cav-Grip Repairing Accidental Holes In The Air Barrier Contractor Responsible: Air Barrier Small Hole Large Hole Carlisle CCW 705 CCW 702 mastic/caulk CCW 705 sheet Barriseal spray/roll grade Barriseal roll grade or CCW 702 mastic/caulk CCW 705 sheet or Barriseal roll grade Dens-Glass CCW 702 mastic/caulk CCW 705 sheet or Barriseal roll grade Air Barrier Tie In Method Contractor Responsible Walls to Windows, Doors, Baraset Closure Louvers Walls to foundation Different wall systems Wall to roof Walls to control joints Walls to utility pipe and duct penetrations

4 Locating Steel Studs Behind Air Barrier Systems Contractor Responsible Typically there is more then one contractor constructing the entire wall assembly. The contractor that is installing the air barrier should mark the air barrier as it is installed indicating where the studs are. The contractor installing the Styrofoam should transfer the marks onto the insulation. Contractor Drywall Air Barrier Insulation Steel Stud Location Responsibility Installation Of Exterior Rigid Insulation Contractor Responsible Best practice is to use a 4 X 8 extruded polystyrene Shiplap insulation installed over the air barrier or substrate. Insulation can be temporarily adhered with CCW Cav-Grip spray adhesive. All joints of the insulation must be tight and boards must be in contact with the substrate. Open joints and loose insulation can cause cold spots in the wall, which can lead to condensation inside the wall. Type/Thickness Insulation Exterior Insulation Extruded Polystyrene Dow Styrofoam Cavitymate Thickness SC Shiplap Extruded Polystyrene Thickness Interior Insulation Dow Styrofoam Z-mate

5 Open Insulation Joints Should Be Sealed With: Contractor Responsible Type Of Insulation Silicone Sealant Spray Foam Polyurethane Styrofoam Dow 795, Pecora 895 Dow Great Stuff Window Grade Air Barrier/ Compatibility With Thur-Wall Flashing Best practice is to have the manufacturer supplying the air barrier also supply the thurwall flashing to assure there is not a compatibility problem with the material. Also it is important to have single responsibility of the entire system. Air Barrier Thur-Wall Flashing Contractor Responsible CCW 705 Sheet 40 Mil CCW 705 Thru-Wall or Barriseal Spray or Roll CCW 705 Thru-Wall or Grade Dens-Glass Taped with CCW 705 Thru-Wall or CCW 705 Masonry Brick Ties Metal Studs And Block Back Up Best practice is to use a brick tie that can be used with a 4 x 8 shiplap Styrofoam insulation board. This will eliminate cold and open joints. Contractor Responsible: Brick Tie Back Up Insulation Size Heckmann Posi-Tie Metal Stud 4 x 8 Shiplap Styrofoam Heckmann Posi-Tie Block 4 x 8 Shiplap Styrofoam FOR MORE INFORMATION GO TO