800 Payson Drive. Oleg Derkach. Single Family Residence A00 STREETSCAPE ELEVATION. 3D View 2 PCDC SUBMISSION

Size: px
Start display at page:

Download "800 Payson Drive. Oleg Derkach. Single Family Residence A00 STREETSCAPE ELEVATION. 3D View 2 PCDC SUBMISSION"

Transcription

1 3D View 70 /5/07 Description No. A00 STREETSCAPE ELEVATION

2 ELEVATION GENERAL NOTES. SLOPE GRADE AWAY FROM FOUNDATION MINIMUM /8 : FOR A DISTANCE OF 8' 0' OR TO A SWALE. 4"x4" ALUMINUM LOUVER VENT WITH INSECT SCREEN " METAL FLASHING 3. BRICK VENEER: ALL SOLDIER AND ROWLOCK HEADERS, SILLS AND TRIM TO PROJECT 5/8. UNLESS NOTED OTHERWISE. KING SIZE MASONRY VENEER 4. ROOF FLASHING: PROVIDE CORROSIONRESISTANT METAL FLASHING AT ALL ROOF VALLEYS, WALL AND CHIMNEY INTERSECTIONS, PORCHES, DECKS, ETC. MASONRY SOLDIER COURSE ' - 0" ALUMINUM FASCIA TRIM T.O PLATE 8' - 3" H 5' - 6" egress window BRICK SILL egress window EXTERIOR MATERIALS ' - 6 /" SILL 7x7 0' - " DOWNSPOUT PAINTED CONCRETE FOUNDATION STONE VENEER ACCENT SILL TEMPEREDTEMPERED ' - 0" STONE ACCENTS LAP SIDING: VINYL SIDING, 6" EXPOSURE. - ALSIDE PRODIGY - CLAPBOARD PROFILE. COLOR TO BE SELECTED BY THE OWNER. SIDING ACCESSORIES - 5" LINEALS AROUND WINDOWS. TRADITIONAL CORNER POST AT CORNERS-COLOR TO MATCH WINDOW SURROUNDS. BOARD AND BATTEN SIDING: (AROUND FRONT DOOR) JAMES-HARDIE "HARDIE PANEL" SMOOTH VERTICAL SIDING AND TRIM. PRE FINISHED COLOR TBD OR PRIMED FOR FIELD PAINT. OVER CONTINUOUS WEATHER RESISTANT MEMBRANE. 0' - " BRICK SILL LEVEL 0' - 0" PAINTED CONCRETE FOUNDATION T.O. FOUNDATION -' - /4" STONE ACCENTS W 4' - 0" x H 5' - 6" 8' - " H 5' - 6" BRICK SILL STONE HEADER 6. WINDOW SIZES REFER TO ROUGH OPENING SIZE 3' - 4 /" KING SIZE MASONRY VENEER 5. GENERAL CONTRACTOR SHALL CONFIRM USE AND TYPE OF ALL TRIM ACCESSORIES WITH SUPPLIER BEFORE ORDERING. " "/ / 0" 7 /4" / " 0 " "/ 0. FOOTINGS & PIERS: BOTTOM OF ALL FOOTINGS TO BE SET ON VIRGIN SOIL.. TOP OF FOOTING SHALL BE A MINIMUM OF 30 BELOW GRADE. PIERS TO EXTEND MINIMUM 4 INTO SOLID VIRGIN SOIL STONE ACCENTS: LIMESTONE, NATURAL, TUMBLED, ASHLAR. HEIGHT (NOMINAL): 8", 5" LENGTH: RANDOM 6-4" DEPTH: 3 ½ - 4 ½ ATTlC VENTILATION: AIRHAWK STATIC ROOF VENTILATORS RVA-5 AS INDICATED. BRICK VENEER: AS SELECTED BY OWNER FRONT ENTRY DOOR: WOOD GRAIN FIBERGLASS DOOR. STYLE AND GLASS AS SELECTED BY OWNER. RETAINING WALL GARAGE DOORS: OVERHEAD INSULATED METAL OR COMPOSITE GARAGE DOORS, TRADITIONAL STYLE, WITH TEMPERED GLASS. (JELD-WEN COMPANY SHOWN) AMARR-OLYMPUS, TO BE CONFIRMED WITH OWNER. ROOFING: COMPOSITE I ASPHALT ARCHITECTURAL SHINGLES AS SELECTED BY OWNER. PROVIDE METAL FLASHING AT VALLEYS AND SIDEWALLS. (SEE GENERAL NOTES AND SPECIFICATIONS) WEST ELEVATION /4" = '-0" GUTTERS & DOWNSPOUTS: PRE FINISHED ALUMINUM OR AS SELECTED BY OWNER. TERMINATE DOWNSPOUT AT GRADE WITH SPLASHBLOCK-OR-PROVIDE BOOT. 0" / " ASPHALT SHINGLE ROOFING T.O PLATE 8' - 3" ALUMINUM FASCIA TRIM 70 /5/07 VINYL SIDING 0' - " No. 0' - " Description ALUMINUM GUTTER H 9' - 7/3" H 8' - " W 5' - 0" x H 3' - 6" WINDOWS AND DOORS: BASIS OF DESIGN IS 00 SERIES DOUBLE HUNG, CASEMENT, AND AWNING WINDOWS BY ANDERSEN OR AS SELECTED BY OWNER MFR'S. VINYL SIDING TRIM ' - /4" GARAGE DOOR LEVEL 0' - 0" T.O. FOUNDATION -' - /4" A00 NORTH ELEVATION /4" = '-0" Exterior Elevations

3 ASPHALT SHINGLE ROOFING 7 /4" / " 7" / " ALUMINUM GUTTER 0' - 6 /" egress window H ' - 6" DRYER EXHAUST egress window ALUMINUM FASCIA TRIM VINYL SIDING 8' - " T.O PLATE 8' - 3" W ' - 6" x W 5' - 0" x W ' - 6" x 4x7 4x7 W 5' - 0" x H 4' - 0" W 5' - 0" x H 3' - 6" AIR CONDITIONING UNITS 0' - " 0' - " TEMPERED TEMPERED PAINTED CONCRETE FOUNDATION ' - /4" LEVEL 0' - 0" T.O. FOUNDATION -' - /4" EAST ELEVATION /4" = '-0" ASPHALT SHINGLE ROOFING ALUMINUM GUTTER KING SIZE MASONRY VENEER SOUTH ELEVATION /4" = '-0" 0" / " 49x48 EGRESS 4 ASPHALT SHINGLE ROOFING ALUMINUM GUTTER ALUMINUM FASCIA VINYL SIDING DOWNSPOUT FIREPLACE VENT? 9' - 8 3/4" 0' - " 8' - " ' - " T.O PLATE 8' - 3" 0' - " LEVEL 0' - 0" T.O. FOUNDATION -' - /4" BASEMENT -9' - 8 3/4" 3' - " ELEVATION GENERAL NOTES. SLOPE GRADE AWAY FROM FOUNDATION MINIMUM /8 : FOR A DISTANCE OF 8' 0' OR TO A SWALE.. FOOTINGS & PIERS: BOTTOM OF ALL FOOTINGS TO BE SET ON VIRGIN SOIL.. TOP OF FOOTING SHALL BE A MINIMUM OF 30 BELOW GRADE. PIERS TO EXTEND MINIMUM 4 INTO SOLID VIRGIN SOIL 3. BRICK VENEER: ALL SOLDIER AND ROWLOCK HEADERS, SILLS AND TRIM TO PROJECT 5/8. UNLESS NOTED OTHERWISE. 4. ROOF FLASHING: PROVIDE CORROSION- RESISTANT METAL FLASHING AT ALL ROOF VALLEYS, WALL AND CHIMNEY INTERSECTIONS, PORCHES, DECKS, ETC. 5. GENERAL CONTRACTOR SHALL CONFIRM USE AND TYPE OF ALL TRIM ACCESSORIES WITH SUPPLIER BEFORE ORDERING. 6. WINDOW SIZES REFER TO ROUGH OPENING SIZE EXTERIOR MATERIALS LAP SIDING: VINYL SIDING, 6" EXPOSURE. - ALSIDE PRODIGY - CLAPBOARD PROFILE. COLOR TO BE SELECTED BY THE OWNER. SIDING ACCESSORIES - 5" LINEALS AROUND WINDOWS. TRADITIONAL CORNER POST AT CORNERS-COLOR TO MATCH WINDOW SURROUNDS. BOARD AND BATTEN SIDING: (AROUND FRONT DOOR) JAMES-HARDIE "HARDIE PANEL" SMOOTH VERTICAL SIDING AND TRIM. PRE FINISHED COLOR TBD OR PRIMED FOR FIELD PAINT. OVER CONTINUOUS WEATHER RESISTANT MEMBRANE. STONE ACCENTS: LIMESTONE, NATURAL, TUMBLED, ASHLAR. HEIGHT (NOMINAL): 8", 5" LENGTH: RANDOM 6-4" DEPTH: 3 ½ - 4 ½ ATTlC VENTILATION: AIRHAWK STATIC ROOF VENTILATORS RVA-5 AS INDICATED. BRICK VENEER: AS SELECTED BY OWNER WINDOWS AND DOORS: BASIS OF DESIGN IS 00 SERIES DOUBLE HUNG, CASEMENT, AND AWNING WINDOWS BY ANDERSEN OR AS SELECTED BY OWNER MFR'S. FRONT ENTRY DOOR: WOOD GRAIN FIBERGLASS DOOR. STYLE AND GLASS AS SELECTED BY OWNER. GARAGE DOORS: OVERHEAD INSULATED METAL OR COMPOSITE GARAGE DOORS, TRADITIONAL STYLE, WITH TEMPERED GLASS. (JELD-WEN COMPANY SHOWN) AMARR-OLYMPUS, TO BE CONFIRMED WITH OWNER. ROOFING: COMPOSITE I ASPHALT ARCHITECTURAL SHINGLES AS SELECTED BY OWNER. PROVIDE METAL FLASHING AT VALLEYS AND SIDEWALLS. (SEE GENERAL NOTES AND SPECIFICATIONS) GUTTERS & DOWNSPOUTS: PRE FINISHED ALUMINUM OR AS SELECTED BY OWNER. TERMINATE DOWNSPOUT AT GRADE WITH SPLASHBLOCK-OR-PROVIDE BOOT. No. Description 70 /5/07 A0 Exterior Elevations

4 Y PAYSON DR. PAYSON DR.

5 PAYSON DR. PAYSON DR.

6 66' - 4" ' - 4 9/6" 4' - 4" 0' - 9" 9' - 7" ' - 0" FD UNFINISHED BASEMENT 3' - 7/6" 5' - 0" 4' - " 34' - 0". BASEMENT SLAB: 3-/" CONCRETIE SLAB OVER 6 MIL. VB (LAP JOINTS MIN. 6' AND SEAL) OVER MIN. 4' GRAVEL OR CRUSHED STONE. (SLOPE TO FLOOR DRAIN).. GARAGE SLAB: 4" CONCRETE SLAB WITH 6"X6" 0 GA MESH OVER MIN. 4" GRAVEL OR CRUSHED STONE. (SLOPE TO GARAGE DOOR MINIMUM 4 UNO.) 3. EXTERIOR PORCH SLABS: 4 CONCRETE SLAB WITH 6"X6" 0 GA MESH OVER MIN. 4" GRAVEL OR CRUSHED STONE.. SLOPE AWAY FROM FOUNDATION WITH EDGES TURNED DOWN BELOW GRADE MINIMUM OR TO TOP OF FOUNDATION WALL. 4. () #4 BARS TOP AND BOTTOM, 4 EACH WAY. TYPICAL AT ALL INTERSECTING WALLS. 5. #4 DOWEL INTO FOUNDATION WALL AND BEND 4 INTO CONCRETE SLAB. TYPICAL AT EXTERIOR PORCH SLABS AND GARAGE SLAB (ADJACENT TO BASEMENT FOUNDATION WALL). 6. HOLD DOWN TOP OF FOUNDATION DOOR TO RECEIVE CONCRETIE SLAB. 7. FOOTINGS & PIERS: BOTTOM OF FOOTINGS TO BE MINIMUM 30" BELOW GRADE. PIERS TO EXTEND MIN. 4 INTO SOLID, UNDISTURBED SOIL AND MIN. 30 BELOW GRADE. 8. DRAINAGE SYSTEM SHALL DISCHARGE BY GRAVITY TO DAYLIGHT OR BE CONNECTED TO AN APPROVED SUMP (MIN. 4" IN DIAMETER OR 0 INCHES SQUARE AND SHALL EXTEND MIN. 4 INCHES BELOW THE BOTTOM OF THE BASEMENT FLOOR. SUMP SHALL HAVE A FITTED COVER.) PROVIDE PUMP IF BASEMENT IS FINISHED OR GROUNDWATIER IS PRESENT. DISCHARGING TO OR WITHIN 0' OF A SIDEWALK, DRIVEWAY, STREET, PROPERTY LINE OR TO CREATE A NUISANCE TO ADJOINING PROPERTIES IS PROHIBITED. 0. CLASS 'B" UL APPROVED HVAC FLUE (SIZED BY HVAC GAS FURNACE AND HWH. PROVIDE MINIMUM " CLEARANCE.. ELECTRICAL PANEL: (00 AMP. MINIMUM 600 AMP. MAXIMUM) TO BE SIZED AND LOCATED BY ELECTRICAL CONTRACTOR.. DOUBLE FLOOR JOISTS AROUND STAIR OPENINGS, FIREPLACE HEARTH, AT CORNERS OF CANTILEVERED BAYS AND UNDER PARALLEL PARTITIONS. IF THE PARTITION RUNS FOR LESS THAN / THE SPAN OF THE JOIST, DOUBLE JOISTS ARE NOT REQUIRED. (TYPICAL). 3. STEEL COLUMNS SHALL BE PER PLAN. ALL COLUMNS SHALL HAVE A CAP AND BASE. ADJUSTABLE COLUMNS PERMITTED UNLESS NOTED TO BE FIXED. 70 /5/07 ' - 3 3/6" 5' - 0 3/6" 4' - 4" 7' - 0" 4' - 4" 3' - 4" 66' - 4" 4. MINIMUM OF ()-#5 REINFORCING BARS SHALL BE PROVIDED AROUND ALL WINDOW AND DOOR OPENINGS IN PLAIN CONCRETE FOUNDATION AND BASEMENT WALLS. BARS SHALL EXTEND A MINIMUM OF 4 BEYOND THE CORNERS OF THE OPENINGS. 5. CONTRACTOR SHALL NOT BACKFILL UNTIL CONCRETE FOUNDATION HAS CURED FOR A MINIMUM OF 7 DAYS. 6. I-.JOIST FLOOR SYSTEM DESIGNATIONS ARE THOSE OF: TJI TRUSS JOIST. COMPLY WITH MANUFACTURERS DETAILS INCLUDING BUT NOTLIMITED TO BEARING, BLOCKING, RIM BOARDS, BRACING AND METAL HANGERS ETC. INCLUDING BLOCKING BETWEEN JOIST AT BEARING WALLS OVER STEEL BEAMS PER MANUFACTURER. 7. ANY WOOD THAT COMES IN CONTACT WITH CONCRETE, SHALL BE PRESSURE TREATED. FOUNDATION PLAN NOTES " = '-0" No. Description BASEMENT PLAN /4" = '-0" A0 Basement Plan

7 66' - /" ' - " 4' - 7 3/4" 5' - 0" 5' - 0 /" A0 ' - 5 /4" 9' - 4" ' - 5 /4" 4' - 0 /4" 5' - 0" 0" ' - 6" ' - 8 /" 7" x 84" DOWNSPOUT AC CONDENSER ' - 5 /4" 4' - 4" ' - 3 3/6" 7' - 3/6" 3' - " A00 6' - 0" 36" x 84" 36" x 84" 36" x 84" GARAGE MUDROOM GARAGE W D 36" x 84" OVEN REF. KITCHEN DW DINING ROOM HANDRAIL 5' - " ' - 3" ISLAND PANTRY X6 PARTITI ON 3' - /" UP TV BATH ' - 8" BREAKFAST 5' - 6" 4' - 6 /8" ENTRY 7" x 84" 8" x 80" 8" x 80" 9 3/4" 697' - 0" 4" x 80" 4" x 80" 5' - 6" 4' - 0 /" 4' - " FAMILY ROOM 4' - 5/6" LIVING ROOM FO SHTG FO SHTG FIRE PLACE DIRECT VENT A0 ' - 5" 8' - " ' - 3/4" 34' - " FLOOR AREAS : 70 /5/07 LEVEL /4" = '-0" 6' - 6 /" 4' - 0" 3' - /" 6' - 8" A00 ' - 4" ' - 8/4" 4' - 4" 7' - 0" 4' - 4" ' - 8" ' - 4" 4' - 0" 66' - /" 5' - 8" 3' - 4" LEVEL TOTAL :,604 SF,0 SF 3,70 SF. ALL INTERIOR WALLS TO BE 3- /" (X4 STUDS), UNLESS NOTED OTHERWISE (UNO).. POST INDICATED SHALL BE MINIMUM X WALL THICKNESS, GLUED AND NAILED UNLESS NOTED OTHERWISE. EXCEPTION: POSTS CARRYING MINIMAL LOADS, LESS THAN 8-0 IN HEIGHT AND SUPPORTING HEADERS SPANNING 3' 0" OR LESS MAY CONSIST OF A SINGLE X CRIPPLE AND () FULL HT. UNBROKEN STUD UNLESS NOTED OTHERWISE. 3. MINIMUM HEADER SIZE () X0'S GLUED AND NAILED. 4. MINIMUM MASONRY LINTELS 3"X3"X/4" UNO No. Description 5. PREFAB ZERO CLEARANCE FIREPLACE AS SELECTED BY OWNER. HEATILATOR REVEAL 48 (4' OPENING) DIRECT VENT GAS PRE-FAB FIREPLACE SHOWN. SURROUND, MANTLE, AND HEARTH TO BE SELECTED BY OWNER. 6. PROVIDE " MINIMUM CLEARANCE TO COMBUSTIBLES AT ALL GAS FLUES, TYPICAL. (VERIFY SIZE & LOCATION) 7. GARAGE/HOUSE SEPARATION WALL TO BE INSULATED MINIMUM R GARAGE ATTACHED: /" DRYWALL ON GARAGE SIDE OF WALL UP TO 5/8" TYPE X DRYWALL CEILING. 9. PROVIDE 36 GAS COOKTOP WITH EXHAUST HOOD. PROVIDE ELECTRIC HOOKUPS PER OWNER. IF EXHAUST EXCEEDS 600 CFM, PROVIDE MAKE UP AIR. ALL EXHAUST TO BE VENTED TO EXTERIOR PER ALL LOCAL CODES. A0 PLAN - GENERAL NOTES " = '-0" First Floor Plan

8 4" / " ' - 5 /" ' - 0" ' - 8 /" ' - " ' - 8 /" A0 4" / " 4" / " 4' - 7 /4" MASTER CLOSET MASTER BATHROOM MASTER CLOSET 3' - " 3' - 03/3" 30" x 80" 5' - 8" 5' - 6" 5' - 8" BEDROOM 3 30" x 80" 3' - /8" 4' - 3/8" MECH 5' - 4" D BATHROOM DRYER VENT EXHAUST PORT ' - 6" 7' - 73/4" W WASHER FDSTANDPIPE WASHER HOSE BIB LAUNDRY 4' - 3/8" 30" x 80" 30" x 80" 36" x 80" 3' - 9 /4" BEDROOM 8' - 9 /" ' - " 4' - 4" 36" x 80" FD 36" x 80" 68" x 80" CO 8" x 80" BATHROOM 5' - /" 33' - 8" CLG PROFILE MASTER BEDROOM PLAYROOM open to below DN 36" x 80" BEDROOM 3' - 3/4" ' - 3 3/4" ' - 5" 7" x 84" A0 4" 4' - " 7' - 0" ' - " 7' - 0" A00 ' - 0" 6' - 0 3/4" 7' - 5" 4' - 3 7/3" HANDRAIL ' - 4" ' - 5" 70 /5/07 ' - 9 /" A00 ' - 4" ' - 8/8" 4' - 4" 7' - 0" 4' - 4" 3' - 5" 66' - /". ALL INTERIOR WALLS TO BE 3- /" (X4 STUDS), UNLESS NOTED OTHERWISE (UNO).. POST INDICATED SHALL BE MINIMUM X WALL THICKNESS, GLUED AND NAILED UNLESS NOTED OTHERWISE. EXCEPTION: POSTS CARRYING MINIMAL LOADS, LESS THAN 8-0 IN HEIGHT AND SUPPORTING HEADERS SPANNING 3' 0" OR LESS MAY CONSIST OF A SINGLE X CRIPPLE AND () FULL HT. UNBROKEN STUD UNLESS NOTED OTHERWISE. No. Description 3. MINIMUM HEADER SIZE () X0'S GLUED AND NAILED. 4. MINIMUM MASONRY LINTELS 3"X3"X/4" UNO /4" = '-0" 5. PREFAB ZERO CLEARANCE FIREPLACE AS SELECTED BY OWNER. HEATILATOR REVEAL 48 (4' OPENING) DIRECT VENT GAS PRE-FAB FIREPLACE SHOWN. SURROUND, MANTLE, AND HEARTH TO BE SELECTED BY OWNER. 6. PROVIDE " MINIMUM CLEARANCE TO COMBUSTIBLES AT ALL GAS FLUES, TYPICAL. (VERIFY SIZE & LOCATION) 7. GARAGE/HOUSE SEPARATION WALL TO BE INSULATED MINIMUM R GARAGE ATTACHED: /" DRYWALL ON GARAGE SIDE OF WALL UP TO 5/8" TYPE X DRYWALL CEILING. 9. PROVIDE 36 GAS COOKTOP WITH EXHAUST HOOD. PROVIDE ELECTRIC HOOKUPS PER OWNER. IF EXHAUST EXCEEDS 600 CFM, PROVIDE MAKE UP AIR. ALL EXHAUST TO BE VENTED TO EXTERIOR PER ALL LOCAL CODES. A03 PLAN - GENERAL NOTES " = '-0" Second Floor Plan

9 TRUSS LAYOUT SHOWN IS FOR DIAGRAMMATIC PURPOSES ONLY. SEE MANUFACTURERS SHOP DRAWINGS FOR ACTUAL LAYOUT. ALL VENTS TO BE LOCATED AT THE REAR. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE VENTING AT THE SOFFIT AND ROOF AS REQUIRED. ROOF PLAN - GENERAL NOTES " = '-0" A0 A00 0" / " 7" / " 0" / " 0" / " ROOF RIDGE ROOF VENT ROOF RIDGE 7 /4" / " 7 /4" / " 30"x4" duct chase 0" / " ROOF RIDGE 0" / " A0 SLO PE 0" / " 70 /5/07 A00 ROOF RIDGE No. Description Roof Plan /4" = '-0" A04 Roof Plan