NEW DROP THE LIGHT. Using the optional drop lens to spread the light while creating a graphical statement into your environment.

Size: px
Start display at page:

Download "NEW DROP THE LIGHT. Using the optional drop lens to spread the light while creating a graphical statement into your environment."

Transcription

1 light ACL5

2 NEW STANDARD ALIGHTANIUM FINISH, SATIN WHITE, AND SATIN BLACK. OTHER COLORS AVAILABLE. STANDARD OR CUSTOM LENGTHS AVAILABLE TO MATCH ANY SPACE (CONSULT WITH FACTORY) DROP LENS -D DIFFUSE WHITE ACRYLIC LENS DROP THE LIGHT Using the optional drop lens to spread the light while creating a graphical statement into your environment.

3 SAY NO TO GLARE NEW For maximum glare reduction and source control, use the optional ACL louvers. Flat blade louvers available in STANDARD And CUSTOM LENGTHS

4 light

5 ACL5 ANATOMY SLEEK & STRONG CORE CAPACITY A stylish rectilinear aluminum extrusion made of 60% recycled material provides ultimate durability and functionality. POWERFUL PERFORMANCE Integral 0-0V dimming driver down to %. Additional options include Lutron, DMX, and DALI control protocols. Integral IOTA slim W emergency battery pack provides an easy solution for egress compliance. High performance Nichia 80+ CRI LEDs provide an optimal light source for tailored lighting design..5 CONTROL FREAK Flat Blade Louvers or Drop Lens options are available when you need a little more control SEAMLESS INTEGRATION The variety of recessed mounting options promote coalescing of light and space PROPRIETARY OPTICS HE Tech lens technology cleanly combines optical diffusion and high performance reflector design to deliver beautifully refined light with uncompromised performance. Visible 0.5 finished trim flange option ELEMENTS Elements is a simplified product line comprised of 4, 8, and nominal length fixtures that can be joined to create continuous rows. INTEGRATIONS Integrations is a comprehensive product line comprised of nominal and exact length fixtures, continuous rows, and patterns comprised of 90 illuminated corners. 4 8 R For rows over (R) fixtures will be shipped in sections. Joining hardware for field installation is provided. CUSTOM A completely custom ordering process allowing unique modifications and non-90 transitions is available through collaboration with Design Assist. light ANATOMY ALIGHTS.COM 5

6 ACL5 PHOTOMETRY LIGHT OUTPUT DISTRIBUTION Direct Symmetric OUTPUT LH: High output W/ft LS: Standard output W/ft C: Custom tuned output - Specify Wattage LIGHT LOSS FACTORS 80+CRI, 4000K: Baseline 80+CRI, 500K: 99% 80+CRI, 000K: 95% 90+CRI, 4000K: 8% 90+CRI, 500K: 8% 90+CRI, 000K: 84% PHOTOMETRIC DATA DIRECT SYMMETRIC LH K - HE TECH Lumens: 96 lm/ft Input watts: 9.5 W/ft Efficacy: 98 lm/w DLH DLS SAMPLE INSTALLATION - WORKSPACE LS DOWN / 4000K Room height: 0 ft x 0 ft x 9 ft Reflectance: 80% / 50% / 0% Mounting height: 9 ft A.F.F. Fixture length: 4 ft Calculation grid: ft x ft Calculation plane (horizontal):.5 ft A.F.F. Average Illuminance: fc Fixture spacing: 0 ft x 0 ft Uniformity:.9: (avg/min) TOP VIEW 0 fc 5 fc 6 PHOTOMETRY ALIGHTS.COM light

7 ACL5 MOUNTING (G) Flush Gyp/Hard Lid (XP) Trim Flange (T) T-bar 9/6 (X) T-bar 5/6 (N) T-bar 9/6 Slot STANDARD PATTERNS CORNER DETAIL Welded corner (PLCW) Wall to ceiling (PLWW) Wall to wall (PLW) Wall only Joining pins (PLC) Ceiling only (PUWW) Wall to wall to wall (PUCW) Wall to ceiling to wall 4 (PUW) Wall only (PUC) Ceiling only (PRW) Wall only 4 (PRC) Ceiling only (CP) Custom pattern light MOUNTING ALIGHTS.COM 7

8 ACL5 TECHNICAL DATA LINEAR DIMENSIONS Elements - 4, 8, and nominal length individual fixtures that can be joined to create continuous row lengths. Integrations - Nominal or exact lengths to the nearest /8th of an inch available as individual fixtures or joined to create continuous row lengths, minimum fixture lengths is inches. Patterns comprised of 90 degree precisely welded fully illuminated corners provide a multitude of geometric options and architectural transitions. Custom - Contact Design Assist for modifications to product not detailed within Elements or Integrations specification sheets. OPTICS He Tech patented high efficacy extruded diffuse acrylic lens technology with integrated opaque white reflector delivers superior lumen output with optimal uniform lens surface luminance for direct distribution. Flat Blade Louvers are used to cut down on glare and better control the light source on ACL or ACL5. This option includes a linear film diffuser (inserted between the louvers and the LEDs), that enhances glare control and lends light sources. The standard finish is satin aluminum. Other colors and custom finish options available, specify RAL# or contact factory regarding custom finish requirement. Drop Lens is a light diffuser option for ACL or ACL5 that turns the luminaire into a decorative graphical statement. The diffuser drops down from the luminaire s main body of and sits flush with the metal end caps. Once lit, the drop lens glows vividly and offers a wider diffusion pattern. LED LIGHT SOURCE Custom manufactured linear board array uses high performance Nichia LED in combination with a performance driven heat sink technology. Tested in accordance with LM79 and LM-80; L70>60,0000hr; operated at reduced output for high efficacy and lumen maintenance. 000K, 500K, and 4000K with 80+ CRI standard; other color temperatures and 90+ CRI available upon request, contact factory. LED color variation maintained at a -step MacAdam ellipse (SDCM x). LEDs are available in Low, Standard, and High outputs. Refer to photometry for delivered lumens. Custom output available in the range 5% to 5% of high output, contact factory. LED DIMMING DRIVER Factory tuned constant current electronic 0-0V control dimming driver is standard. Specification grade dimming down to %. Driver life of 50,000 hrs with ambient operating temperature range of -0 C to 50 C, maximum case temperature of 75 C. Electrical specifications at maximum driver load: PF >0.9, THD <0%, >85% Efficiency. Other available drivers include Lutron Hi-lume % EcoSystem LED Driver (LDE) with Soft On, Fade to Black dimming technology; and DMX and DALI protocol drivers. Other Lutron and specialty drivers available, contact factory. EMERGENCY This luminaire is provided with a factory installed LED emergency lighting battery pack for both normal and emergency operation, 0-77v only. This fixture integrated unit contains long-life Ni- Cad recyclable battery, 4 hour charger, and converter circuit. Test switch and charge indicator provided. Test button to be remote located within feet of the luminaire, by others in accordance with local code. Emergency mode provides constant power to a nominal W LED load for a period of 90 minutes, delivering 00 lumens of unwavering illumination throughout the full 90 minute emergency duration. Unless otherwise specified, the emergency battery pack will illuminate one foot end in the direct portion of the fixture. Emergency circuiting provided as a separate circuit from normal power circuit according to NEC requirements, specify circuit length and location. CONTROLS Low-profile integral occupancy and daylight sensors are available to deliver high performance control in an architecturally pleasing package. Integral occupancy sensor - the sleek Wattstopper FS-05 modular plugin system utilizes a RJ45 connector, low voltage cord, and power pack. Automatic on/off passive infrared (PIR) occupancy sensing control covers a range of 00 square feet for a specified 0 second to 0 minute time delay with an optional ambient daylight sensing function to hold lights off when specified adequate daylight level is sensed. Factory default time delay of 0 minutes and 0fc light level. Settings can be adjusted at the factory or easily in the field. Integral daylight sensor - the sophisticated Wattstopper FD-0 is a low voltage controller using 0-0VDC input to automatically dim the electric lighting system based on daylight contribution in a 70 field of view to achieve a target illuminance using a sliding setpoint algorithm. This single zone closed loop daylight harvesting control system utilizes a RJ45 connector, low voltage cord, and power pack. One () LSR-0-S setup remote control to adjust target let levels is provided per order. Combined occupancy and daylight sensing is achieved using both the FS- 05 and FD-0 for more versatile control functionality including automatic on/off occupancy and daylight dimming response. Other manufacturer controls may be available for product integration, contact factory. MOUNTING Common recessed mounting options available. Contact factory for applications regarding modified recessed mounting conditions. Flush Gypsum Flange. Raw aluminum flange is attached to blocking (by others), then mudded over and/or painted by installing contractor to provide a flangeless fixture appearance in recessed ceiling/wall applications. Trim Flange. / wide visible powder coated flange, specify finish requirement. Fixture is mounted to structure using threaded rod (by others) or ceiling tie wires (provided). Use of a-clamp secures fixture trim and housing around ceiling/wall material. Use for any gypsum or hard ceiling/ wall that requires a minimal flange covering the ceiling cut-out edge. 9 TECHNICAL DATA ALIGHTS.COM light

9 ACL5 TECHNICAL DATA T-Bar/Grid Ceiling. 9/6 or 5/6 standard T-Bar or 9/6 slot ceiling. Raw aluminum flange sits on T-Bar and is concealed from view. 9/6 or 5/6 standard T-Bar or 9/6 slot ceiling. Suitable for use in 4 on-center standard or slot T-Bar systems. Approximate wide visible side flanges create a seamless 4 slot condition, specify finish requirement. STRUCTURE Robust, high quality 60% recycled aluminum extruded housing thick aluminum internal gear trays. Flat or flanged aluminum end caps. Aluminum joiner brackets. 4 lbs/ft approximate fixture weight.finish Electrostatically applied powder coat finish. Standard finish options include alightanium, satin white, and satin black. Other colors and custom finish options available, specify RAL# or contact factory regarding custom finish requirement. LISTING IC Rated for IC, Airtight, CCEA Ceilings. CCEA mark applied for Chicago Plenum applications. UL/CUL rated for Damp Locations. Tested in accordance with UL 598 and certified to CEC/CSA C., NEC, ANSI/ NFPA 70, and NOM-00-SEDE. UL Wet location label available. Complies with UL definition of wet locations to prevent accumulation of water on live parts, electrical components, or conductor not identified for use in contact with water through the provision of weep holes. Waterproof connector to be provided by others. Installing contractor responsible for properly sealing and waterproofing all field drilled mounting and power feed locations. WARRANTY Limited defect-free manufactured equipment warranty provided under normal use and proper storage for a period of one () year. LED products (LED boards and drivers) will be covered for a period of five (5) years. Please refer to full terms and conditions on our website. Wet location fixtures are not recommended for extreme wet weather conditions and must be installed according to factory drawings; there is a modified warranty for LED components installed in applications not in accordance with factory recommendations/drawings. Please refer to full terms and conditions on our website. light TECHNICAL DATA ALIGHTS.COM 0

10 light 78 MARITIME WAY, OCEANSIDE, CA ALIGHTS.COM/ACL5