SECTION UNDERSLAB WATERPROOFING WITH INSECT BARRIER

Size: px
Start display at page:

Download "SECTION UNDERSLAB WATERPROOFING WITH INSECT BARRIER"

Transcription

1 SECTION UNDERSLAB WATERPROOFING WITH INSECT BARRIER ************************************************************************************************************************ This guide specification has been prepared by Polyguard Products Inc., in printed and electronic media, as an aid to specifiers in preparing written construction documents for Underslab insect barrier and waterproofing membrane systems. Polyguard TERM Underslab Barrier is used as a waterproofing membrane/vapor barrier to virtually eliminate water and vapor transmission through concrete slabs on grade. In addition to protecting floor finishes and indoor air quality, TERM Underslab Barrier also acts as a barrier to insects, pesticides, methane gas and radon gas. Edit entire master to suit project requirements. Modify or add items as necessary. Delete items which are not applicable. Words and sentences may contain a choice to be made regarding inclusion or exclusion of a particular item or statement. This section may include performance, proprietary and descriptive type specifications. Edit to avoid conflicting requirements. Editor notes to guide the specifiers are included between lines of asterisks to assist in choices to be made. Remove these notes before final printing of specification. This guide specification is written around the Construction Specifications Institute (CSI) Section Format standards. For specification assistance on specific product applications, please contact our offices above or any of our local product representatives throughout the country. Polyguard Products Inc. reserves the right to modify these guide specifications at any time. Updates for this guide specification will be posted on the manufacturer s web site and/or in printed matter as they occur. Manufacturer makes no expressed or implied warranties regarding content, errors, or omissions in the information presented. ************************************************************************************************************************ PART 1 GENERAL 1.01 SECTION INCLUDES A. Surface preparation. B. Application of underslab barrier system. C. Accessory Products 1.02 RELATED SECTIONS ************************************************************************************************ Specifiers Notes: Edit the list of related sections as required for the project. List other sections dealing with work directly related to this section. ************************************************************************************************ A. Section Cast-in-Place Concrete. B. Section Thermal Insulation. C. Section Flashing and Sheet Metal. D. Section Joint Sealants. E. Section Sub drainage REFERENCES A. ASTM D Standard Test Method for Grab Breaking Load and Elongation of Geotextiles B. ASTM D412 - Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers- Tension. C. ASTM D570 - Standard Test Method for Water Absorption of Plastics. Polyguard Products Underslab Waterproofing with Insect Barrier

2 D. ASTM E96 (Method B) - Standard Test Methods for Water Vapor Transmission of Materials. E. ASTM E154- Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover. F. ASTM D Standard Test Method for Tensile Properties of Thin Plastic Sheeting G. ASTM F Standard Test Method for Measuring Repellency, Retention, and Penetration of Liquid Pesticide Formulation Through Protective Clothing Materials H. ASTM D Standard Test Method for Peel Resistance of Adhesives (T Peel Test) I. ASTM D Test Method for Determining Gas Permeability Characteristics of Plastic Film and Sheeting. J. General Services Administration, Public Building Service: GSA-PBS Guide Specification for Elastomeric Waterproofing. K. ASTM D Test Method for Determining the (In Plane) Hydraulic Transmissivity of a Geosynthetic by Radial Flow L. Radon Reduction Technology Laboratory - Resistance to Permeance by Radioactive Radon Gas; Resistance to Diffusion by Radioactive Radon Gas. M. ASTM D Standard Test Method for Peel or Stripping Strength of Adhesive Bonds. N. ASTM C Standard Specification for High Solids Content, Cold Liquid Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course. O. ASTM D Standard Specification for Self Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection P. ASTM D Test Method for determining the (In plane) Flow Rate per Unit Width and Hydraulic Transmissivity of a Geosynthetic Using a Constant Head. Q. ASTM D (2006) Standard Test Method for Hydrostatic Pressure Resistance of Waterproofing Membranes. R. ASTM D Standard Test Method for Evaluating Wood Preservatives 1.04 SUBMITTALS A. Product Data: Submit manufacturer s product data, installation instructions, use limitations and recommendations. Include certification of data indicating VOC (Volatile Organic Compound) content of all components of waterproofing system. B. Samples: Submit representative samples of the following for approval: 1. Underslab Barrier 2. Barrier Tape and Accessories. C. Sustainable Design Submittals: 1. Submit invoices and documentation from manufacturer of the amounts of materials and content for products specified. 2. Submit invoices and documentation showing manufacturing locations and origins of materials for products manufactured and sourced within 500 miles of project location. Polyguard Products Underslab Waterproofing with Insect Barrier

3 D. LEED Submittal: Documentation of materials, recycled content and location of manufacturer QUALITY ASSURANCE 1. LEED MR Credit 2 Construction Waste Management: Provide documentation of reusable materials by weight and volume diverted back to manufacturing process or to appropriate sites. 2. LEED, MR Credit 5 Regional Materials: Provide documentation for cost of materials or products that have been extracted, harvested, or recovered and also manufactured within 500 miles of project site. a. If only a portion of the materials or products is extracted, harvested, or recovered and manufactured locally, then only provide percentage by weight for credit value. 3. LEED, SS Credit 3 Brownfield Development: Provide documentation of materials that contribute to the redevelopment of a contaminated land site that has been defined as a brownfield by a local, state or federal government agency. 4. LEED, EQ Credit 5 Indoor Chemical and Pollutant Source Control: Provide documentation of long term testing of ability to physically block access by termites and other insects into the structure, thus reducing future usage of pesticides. Provide documentation of ability to physically block penetration of residual pesticides in the ground into the structure. Provide documentation of ability to physically block penetration of radioactive radon gas into the structure. Provide documentation of ability to physically block penetration of methane gas into the structure. 5. LEED, ID Credit 1: 1.1 Provide documentation of long term testing supporting the environmental and health benefits obtained through the physical blocking of insects and other pests from entry to the structure, therefore reducing the need for application of pesticides over the life of the structure. 1.2 Provide documentation of testing supporting the environmental and health benefits obtained through the physical blocking of radioactive radon gas from entry to the structure from the ground underneath. 1.3 Provide documentation of ability of the underslab vapor barrier maintain its integrity during and after concrete construction by very high puncture resistance, strength, and self-healing properties A. Manufacturer Qualifications: Underslab Barrier System must be manufactured by a company with a minimum of 10 years of experience in the production and sales of membrane waterproofing materials, as well as technical and sales personnel with backgrounds in entomology and/or pest control. B. Applicator Qualifications: A firm having at least 5 years of experience in applying these types of specified materials and specifically accepted in writing by the barrier system manufacturer. C. Materials: For each type of material required to complete the work of this section, provide primary materials which are the products of a single manufacturer. D. Pre-Application Conference: A pre-application conference shall be held to establish procedures and to review conditions, installation procedures and coordination with other related work. Meeting agenda shall include review of special details and flashing. E. Manufacturer s Representative: Arrange to have trained representative of the manufacturer on site periodically to review installation procedures. Representative(s) must be trained in pest control as well as waterproofing DELIVERY, STORAGE, AND HANDLING A. Deliver materials to site in manufacturer's original, unopened containers and packaging, with labels clearly identifying product name and manufacturer. Polyguard Products Underslab Waterproofing with Insect Barrier

4 B. Store materials in a clean, dry area in accordance with manufacturer's instructions. C. Store adhesives and Underslab barrier at temperatures of 40 o F (5 o C) and above to facilitate handling D. Store barrier cartons on pallets. E. Do not store at temperatures above 90 o F (32 o C) for extended periods. F. Keep away from sparks and flames. G. Completely cover when stored outside. Protect from rain. H. Protect materials during handling and application to prevent damage or contamination. I. Avoid use of products which contain tars, solvents, pitches, polysulfide polymers, or PVC materials that may come into contact with waterproofing barrier system PROJECT CONDITIONS A. Work should be performed only when existing and forecasted weather conditions are within the limits established by the barrier manufacturer. Barrier should only be installed when temperature is 40 F (4.44 C) and rising. Consult manufacturer for information concerning cooler temperatures. B. Proceed with installation only when substrate construction and preparation work is complete. Ensure that subsoil is approved by architect or geotechnical firm. C. Warn personnel against breathing of vapors and contact with skin and eyes; wear appropriate protective clothing and respiratory equipment. D. Keep flammable products away from spark or flame. Post No Smoking signs. Do not allow spark producing equipment to be used during application and until all vapors have dissipated. E. Maintain work area in a neat and workmanlike condition. Remove empty cartons and rubbish from the site daily WARRANTY A. Provide a written 5 year material warranty from the manufacturer upon completion and acceptance of the installation. PART 2 PRODUCTS 2.01 MANUFACTURER A. Polyguard Products Inc. P.O. Box 755 Ennis, TX ; Phone: Fax: info@polyguardproducts.com 2.02 SYSTEM MATERIALS A. High Strength Insect Barrier and Waterproofing: Shall be Polyguard TERM Underslab Waterproofing and Insect Barrier, a 95 mil rubberized asphalt membrane consisting of a strong sheet membrane with a double thickness high strength cross-laminated polyethylene backing topped with a 65 mil thick layer of proprietary barrier sealant integrated into a high strength nonwoven geotextile fabric. On the fabric side, a 4" wide lap of waterproofing adhesive compound is left exposed along one edge with a removable silicone coated plastic release sheet, which creates a 4"wide self-adhesive overlap seam. Polyguard Products Underslab Waterproofing with Insect Barrier

5 PHYSICAL PROPERTIES OF UNDERSLAB BARRIER Long Term Resistance to Termite and Insect Penetration 4 Field sites over five years vs controls Tensile Strength of 1 width Polypropylene Geotextile layer 100% effective ASTM D lb./ 36.3 kg ASTM D Resistance to Penetration by Pesticides 0.0% ASTM F Resistance to Permeance by Methane Gas 2.66 x 10-7 ASTM D Resistance to Permeance by Radioactive Radon Gas 2.1 x Radon Reduction Technology Laboratory Method 6. Resistance to Diffusion by Radioactive Radon Gas 5.08 x 10-8 Radon Reduction Technology Laboratory Method 7. Resistance to Fungi in Soil 16 Weeks No effect GSA-PBS Lap peel adhesion 8.7 lb. /983 N/mm ASTM D 1876 (modified die C) lb./in width 9. Puncture Resistance minimum 10. In Plane Hydraulic Transmissivity of a Geosynthetic by Radial Flow 224lb / 996N ASTM E 154 using 1" (24mm) Rod No water flow ASTM D Peel adhesion to concrete 12. Membrane Thickness 20 lb. /2275 N/mm.095 inches /2.41cm ASTM D 903 lb./in width (N/mm) ASTM D Elongation, rubberized asphalt sealant/adhesive component 839% ASTM D Water absorption, maximum.1% ASTM D Cycling Over cycles No effect ASTM C Low temperature flexibility No effect No Effect No effect ASTM D bend over 1 mandrel at -20 F (-29 C). 17. Hydraulic Transmissivity of a Geosynthetic Using a Constant Head No measurable flow ASTM D Self Sealability - Water Vapor Transmission,maximum.01 ASTM E-96 B US perms (ng/(pa x s x m2) 19. Resistance to hydrostatic head, minimum 231 ft./ 70 m ASTM D Breaking Strength of 1 width sample Polyethylene backing layer 5470 PSI / (N/mm2) ASTM D 882 PSI 2.03 SYSTEM ACCESSORIES A. Surface Roller Grade Adhesive or Sealant: 1. Polyguard 650 LT Liquid Adhesive: A rubber based adhesive in solvent solution which is specifically formulated to provide excellent adhesion with Polyguard Membranes to prepare all TERM Underseal Barrier endlaps and areas around penetrations. Designed to be used on applications down to 25 F (-4ºC). 2. Polyguard California Sealant: A rubber based sealant in solvent solution which is specifically formulated to provide excellent adhesion with the Polyguard Waterproofing Membrane. The VOC (Volatile Organic Compound) content meets the South Coast Air Quality Management District regulations established under the February 1, 1991 Polyguard Products Underslab Waterproofing with Insect Barrier

6 B. Repairs and End Laps version of Rule 1168 ) (2) Adhesion and Sealant Applications. Polyguard California Sealant is classified as an Architectural Sealant Primer Porous; with VOC of 521 g/l. Current SCAQMD regulations for this type sealant primer are 775 g/l. 1. Polyguard TERM UVR Barrier: Fabric backed barrier used for repairs and end laps. C. Detailing at Penetrations - WATERPROOFING 1. Polyguard FastPitch Penetration Sealant Collar 2. Polyguard LM 85 Self Leveling Sealant. D. Detailing at Penetrations INSECT Barrier 1. Polyguard TERM Penetration Barrier: Gunnable sealant barrier used around pipe penetrations. E. Terminations onto Vertical PART 3 EXECUTION 3.01 EXAMINATION 1. Polyguard Sill Plate / Detailing Barrier A. Examine surfaces to receive membrane. Notify General Contractor if surfaces are not acceptable. Do not begin surface preparation or application until unacceptable conditions have been corrected SURFACE PREPARATION A. Protect adjacent surfaces not designated to receive waterproofing and insect barrier. B. Prepare surfaces to receive waterproofing and insect barrier in accordance with manufacturer's instructions APPLICATION A. Horizontal Application shall be in accordance with manufacturer s instructions and ASTM E Unroll barrier membrane with longest dimension parallel with direction of pour. 2. Place high strength polyethylene backing to the soil underneath and fabric on top. 3. Lap waterproofing barrier membrane over footings and seal to foundation walls. 4. Overlap side seams using the maximum 4" edge trim seal. If polyethylene backing has become dirty, clean its surface with 30% Isopropyl Alcohol prior to application on the 4" edge seal. 5. End laps should be overlapped a minimum of 4" and addressed by applying a coat of liquid adhesive or sealant approximately sq. ft. per gallon to fabric side of barrier membrane and placing adjacent sheet on top. 6. After application of end lap use liquid adhesive or sealant to prepare seam and apply a 12" piece of UV resistant barrier tape centered over seam to seal extend out 6 past side laps. Polyguard Products Underslab Waterproofing with Insect Barrier

7 7. Roll side seams and end laps with a minimum 75 lb. steel roller to assure full adhesion. 8. For penetrations waterproofing: a. Apply liquid adhesive or sealant a minimum of 4 out from penetrations. b. Install Polyguard FastPitch around penetrations, with a minimum of 4 between all penetrations and the collar. c. Push up any sleeves on penetrations from the portion of the penetration where the pourable LM85 sealant and TERM Penetration Barrier Sealant will be applied (minimum of 3 up) d. Penetrations should have a clean surface (wire brush or sand) before pourable sealant is applied. e. Apply LM 85 Self Leveling Sealant at all penetrations extending a minimum of 4 onto underslab barrier membrane, and 2 in depth, completely filling the FastPitch collar. f. Allow LM 85 to cure until solid (30 minutes to 2 hours depending on conditions. 9. For penetrations TERM Penetration Barrier (this step must be performed by a Polyguard approved pest control applicator: a. Apply minimum ½ width bead on gunnable TERM Penetration Barrier around the neck of each penetration. 10. Steel reinforcements will be applied directly over the barrier membrane. It is of utmost importance that reinforcement (rebar) chairs that are used are compatible with the system. Steel chairs and bolsters should be plastic dipped or have plastic caps. 11. Precaution should be taken to protect the barrier membrane during placement of reinforcing or concrete. Visually inspect barrier membrane prior to pouring of concrete for any punctures or damage to membrane which needs to be repaired. Patch any damaged areas by applying the liquid adhesive at a rate of sq. ft. per gallon to fabric side of waterproofing barrier membrane and apply a patch of fabric tape. 12. Prior to slab pour all standing water must be removed from the membrane. END OF SECTION X:/Lit/31/Guide Spec TERM Underslab Barrier R Polyguard Products Underslab Waterproofing with Insect Barrier