AVM System 500. Aussie Membrane 500

Size: px
Start display at page:

Download "AVM System 500. Aussie Membrane 500"

Transcription

1 Generic Spec TECH DATA SHEET Sections / / ICC ESR-2503 L.A. RR#: Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections / / Fluid Applied Waterproofing Product Name Manufactured by Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent longterm stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Retaining Walls: Waterproof below-grade, concrete, block walls, basements, etc. Planters: Waterproof planters and other landscaping features. In-between slab waterproofing: To provide a sandwich membrane in-between two concrete slabs or over wood decks that will receive a topping slab. Also used as an under-tile membrane when a mud-bed or thick-set type assembly is required. Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on type of application and the type of surfaces it s being applied to. For specific application procedures, refer to, or download the appropriate installation instructions. (For Retaining Walls, refer to the Retaining Walls Installation Instructions. For Planters, refer to the Planters Installation Instructions, etc.) Basic installation procedures are also provided in the Spec Data Sheet of each type of installation. For a complete/comprehensive set of instructions, however, please refer to the Installation Instructions documents. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. Use AVM Foam Board, AVM Drainage Boards or AVM Approved Protective Panels. Refer to the spec Data Sheets or to the Min Thickness Table for protection details. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: or or visit System Specifications See next page. Tech Data Sheet Rev. 08/2018 1/2 AVM Document # Generic

2 The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black gr/cm² 18 sq.ft./gal. (90 60 Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m² 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer /5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal lbs 19 Grams/Liter Retaining Wall with Aussie Membrane In-Between Slab Waterproofing Retaining Wall Concrete Slab Aussie Membrane Topping Slab Cant Strip Aussie Membrane Footing Block Walls with Aussie Membrane Planter with Aussie Membrane Aussie Membrane Aussie Membrane Block Wall Protection Board Block Wall Drainage Board Aussie Membrane Planter Wall Drainage Board Dirt Cant Strip Drainage Pipe Cant Strip Drainage Pipe Slope to Drain Footing Footing Drain For a complete list of details in CAD or PDF, please visit our website at Quality Waterproofing Products Tech Data Sheet Rev. 08/2018 2/2 AVM Document # Generic

3 Planters Spec TECH DATA SHEET Sections / / ICC ESR-2503 L.A. RR#: Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections / / Fluid Applied Waterproofing Product Name Manufactured by Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent long-term stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Planters: For waterproofing planters made of block or concrete. Important note: For Green Roofs (Roof Gardens) please refer to the Green Roofs Spec Data Sheet. Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on application surfaces. Following are common (Generic) application procedures only. For specific application procedures, download the appropriate installation instructions. Preparation 1. Make sure surface is even without holes, gaps, etc. Make sure substrate has no cracks larger than 1/16" wide. Pay special attention to shrinkage cracks between the blocks and the mortar at the block s joints. 2. If necessary, apply a thin slurry coat using AVM Crete Apply a 4"x4" mortar cant at 45 at the cold joints. (Where the block meets the footings) 4. Priming is highly recommended! Especially if surfaces are old, dusty or very dense (such as solid concrete) Always use AVM Primer 500 when installing over horizontal surfaces. Apply Primer using roller, brush or sprayer. Membrane Installation Roller/Brush: Apply a liberal coat of the Aussie Membrane 500 to all surfaces. (Roll up and down) Allow to cure until dry to the touch. Apply a second coat of the Aussie Membrane 500 going side to side. Allow to dry to the touch. Check for pinholes and proper thickness using a mil gauge. Make sure it=s a minimum 60 mils at all places when completely dry and 90 mils if still wet. Full cure is typically achieved after 24 hours. Drying times may vary based on temperature, humidity and other factors. Applying a third coat is highly recommended. Spray: Mix contents in bucket with drill and paddle for seconds. Product will thin out significantly. (The thinning does not affect performance) Do NOT add water! Use an airless sprayer to apply. Apply product until saturated but stop before dripping or sagging occurs. Once dry to the touch, apply a second coat spraying in the other direction. Check for thickness. (60 mils dry / 90 mils wet) Important Notes: mils dry is highly recommended. 2. Although it is possible to spray 60 dry mils in one coat, doing so in two coats reduces the chances of leaving spots and pinholes uncovered or with too little product. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. c. Perform a 24 hour water test whenever possible. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. First install a root barrier (such as ¼ Apoc Protective Panels) or other approved root barrier. Then, on horizontal surfaces, install AVM Drain Board On vertical surfaces, install AVM Drain Board Refer to Technical Details, Min Thickness Table and Installation Instructions for more info. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: or or visit System Specifications See next page. Tech Data Sheet Rev. 08/2018 1/2 AVM Document # Planters

4 The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black gr/cm² 18 sq.ft./gal. (90 60 Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m² 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer /5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal lbs 19 Grams/Liter SOIL PROTECTION BOARD OR DRAINAGE BOARD 60 MIL AVM SYSTEM 500 AUSSIE MEMBRANE 500 PRIMER 500 CONCRETE WEEP SCREED SHEET METAL FLASHING TERMINATION BAR SOIL PROTECTION BOARD OR AVM DRAINAGE BOARD 60 MIL AVM SYSTEM 500 AUSSIE MEMBRANE 500 PRIMER 500 EXTERIOR WALL PLANTER PLANTER PLANTER SLOPE CONCRETE TO DRAIN AVM SYSTEM 500 AUSSIE MEMBRANE 500 DETAIL COAT AT 45 ± 5 MILS WITH REINFORCING FABRIC MIN 3 X 3 MORTAR CANT STRIP OTHER ACCEPTABLE TERMINATIONAS For a complete list of details in CAD or PDF, please visit our website at Quality Waterproofing Products Tech Data Sheet Rev. 08/2018 2/2 AVM Document # Planters

5 Retaining Walls Spec TECH DATA SHEET Sections / / ICC ESR-2503 L.A. RR#: Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections / / Fluid Applied Waterproofing Product Name Manufactured by Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent long-term stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Retaining Walls: Waterproof below-grade, concrete, block walls, basements, etc. Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc.. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on application surfaces. Following are common (Generic) application procedures only. For specific application procedures, download the appropriate installation instructions. Preparation 1. Make sure surface is even without holes, gaps, etc. Make sure substrate has no cracks larger than 1/16" wide. Pay special attention to shrinkage cracks between the blocks and the mortar at the block s joints. 2. If necessary, apply a thin slurry coat using AVM Crete Apply a 4"x4" mortar cant at 45 at the cold joints. (Where the block meets the footings) 4. Priming is highly recommended! Especially if surfaces are old, dusty or very dense (such as solid concrete) Always use AVM Primer 500 when installing over horizontal surfaces. Apply Primer using roller, brush or sprayer. Membrane Installation Roller/Brush: Apply a liberal coat of the Aussie Membrane 500 to all surfaces. (Roll up and down) Allow to cure until dry to the touch. Apply a second coat of the Aussie Membrane 500 going side to side. Allow to dry to the touch. Check for pinholes and proper thickness using a mil gauge. Make sure it=s a minimum 60 mils at all places when completely dry and 90 mils if still wet. Full cure is typically achieved after 24 hours. Drying times may vary based on temperature, humidity and other factors. Applying a third coat is highly recommended. Spray: Mix contents in bucket with drill and paddle for seconds. Product will thin out significantly. (The thinning does not affect performance) Do NOT add water! Use an airless sprayer to apply. Apply product until saturated but stop before dripping or sagging occurs. Once dry to the touch, apply a second coat spraying in the other direction. Check for thickness. (60 mils dry / 90 mils wet) Important Notes: mils dry on vertical block walls is highly recommended. 2. Although it is possible to spray 60 dry mils in one coat, doing so in two coats reduces the chances of leaving spots and pinholes uncovered or with too little product. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. Install the AVM Drain Board 6000 and appropriate drainage system. Refer to Technical Details, Min Thickness Table and Installation Instructions for more info. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: or or visit System Specifications See next page. Tech Data Sheet Rev. 08/2018 1/2 AVM Document # Retaining Walls

6 The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black gr/cm² 18 sq.ft./gal. (90 60 Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m² 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer /5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal lbs 19 Grams/Liter Slab on Grade at Top of Footing Earth Gravel Backfill (not required if drainage board used) Termination at Grade Backer Rod and Sealant by Others Concrete Wall Waterstop Slab on Grade over Vapor Barrier Drainage or Protection 60 mils *See note. Detail 45 ±5 mils with filter fabric Min 3 x3 Mortar Cant Strip Primer Termination Bar Paving with Protection or Drainage Board Gravel Perforated Drainage Pipe Top of Footing Less of Eq. 3 Note: For applications deeper than 6 feet, see Thickness Chart. For a complete list of details in CAD or PDF, please visit our website at Quality Waterproofing Products Tech Data Sheet Rev. 08/2018 2/2 AVM Document # Retaining Walls

7 Topping Slabs Waterproofing TECH DATA SHEET Sections / / ICC ESR-2503 L.A. RR#: Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections / / Fluid Applied Waterproofing Product Name Manufactured by Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent long-term stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Between Slabs / Topping Slabs / Hard Rock: For waterproofing between two slabs, under topping slabs, under hard rock and other sandwiched applications. Important notes: May be applied over concrete or plywood substrates. (See details) Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc.. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on application surfaces. Following are common (Generic) application instructions for applications over concrete only. For detailed installation instructions, download the appropriate installation instructions. Preparation 1. Make sure concrete surfaces are even without holes, gaps, etc. Make sure substrate has no cracks larger than 1/16 wide. (If applying over plywood substrates, refer to the Between Slab Installation Instructions and Details for more information) 2. If necessary, apply a thin slurry coat using AVM Crete Apply a 1x1 mortar cant at 45 at horizontalto-vertical transitions. Then apply a detail coat. (See details) 4. Primer: Apply AVM Primer 500 using a roller, brush or sprayer to all surfaces and allow to dry to the touch before installing the Aussie Membrane 500. Membrane Installation Roller/Brush: Apply liberal coats of the Aussie Membrane 500 to all surfaces until the desired thickness is achieved. (see AVM Aussie Membrane Min Thickness Table for more info) Allow to cure between coats. Check for pinholes, bubbles and proper thickness using a mil gauge. Fix any imperfections as needed. Full cure is typically achieved after hours after the final coat was installed. Drying times may vary based on temperature, humidity and other factors. Spray: Mix contents in bucket with drill and paddle for seconds. Product will thin out significantly. (The thinning does not affect performance) Do NOT add water! Use an airless sprayer to apply. Apply product until saturated but stop before dripping or sagging occurs. Once dry to the touch, apply a second coat spraying in the other direction. Continue to apply coats until the desired thickness is achieved. Important Notes: It s better to apply multiple thin coats Vs. one or two thick coats. Applying coats too thick could cause material to crust over and slow down curing times. It could also lead to bubbling and delaminations. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. Install optional protective Panels and appropriate AVM Drainage Boards. Refer to Technical Details, Min Thickness Table and Installation Instructions for more info. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: or or visit System Specifications See next page. Tech Data Sheet Rev. 08/2018 1/2 AVM Document # Topping Slabs

8 The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black gr/cm² 18 sq.ft./gal. (90 60 Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m² 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer /5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal lbs 19 Grams/Liter Topping slab Topping slab Min. 120 mil fully reinforced (consult w/avm for membrane thickness requirements) Min. 120 mil fully reinforced (consult w/avm for membrane thickness requirements) For a complete list of details in CAD or PDF, please visit our website at Quality Waterproofing Products Tech Data Sheet Rev. 08/2018 2/2 AVM Document # Topping Slabs