Contact Name Mapei Title Phone

Size: px
Start display at page:

Download "Contact Name Mapei Title Phone"

Transcription

1 Name Ultra Bond Product ID ECO 980 Classification Material Processing and Handling Equipment: Adhesive Joining Equipment Website Manufacturer Address Cornerstone Floor Group 1144 East Newport Center Drive Deerfield Beach, FL Contact Name Mapei Title Phone Description Ultrabond ECO 980 Professional Urethane Wood-Flooring Adhesive Description Ultrabond ECO 980 is MAPEI s 100%-solids, one-component moisture-cured urethane adhesive, recommended for mainstream wood floor installation. Ultrabond ECO 980 s formulation is perfectly suited for traditional solid wood flooring and engineered wood flooring of all sizes. Easy to trowel, Ultrabond ECO 980 exhibits quick grab to hold planks in place during installation, yet it provides enough slip time to align everything perfectly. Features and Benefits Easy to trowel, with excellent trowel ridge hold-out for proper adhesive bonding 100%-solids formulation; no solvent added Utilizes rapidly renewable raw materials Excellent green strength to hold planks in place during installation Extremely low-odor formula with negligible VOC content Approved for use with solid hardwood planks or shorts; parquet; acrylic impregnated wood and laminated plank; bamboo flooring; cork underlayment; and all sizes of engineered wood flooring Approved for use with ceramic tile and stone in mixed media installations using wood flooring * Consult MAPEI s Technical Services Department for recommendations regarding bamboo, as some bamboo flooring is not suitable for direct bonding methods. Industry Standards and Approvals LEED Points Contribution LEED Points MR Credit 5, Regional Materials**... Up to 2 points MR Credit 6, Rapidly Renewable Materials...1 point IEQ Credit 4.1, Low-Emitting Materials Adhesives & Sealants...1 point ** Using this MAPEI product may help contribute to LEED certification of projects in the categories shown above. Points are awarded based on contributions of all project materials. Where to use Interior residential (rental apartments, condominiums, homes) Interior commercial (office buildings, hotel rooms and hallways, restaurant dining areas) Interior heavy commercial (hotel lobbies, convention centers, airports, department stores) Interior institutional (hospitals, schools, universities, libraries, government buildings) Limitations Do not install over any substrates containing asbestos. For interior installations only Not recommended for flooring designed for nail-down installations only Do not apply over any adhesive residues including cutback adhesive. Do not install in areas not recommended by the wood flooring manufacturer. Ul tr ab o nd E C O Do not install when the moisture vapor emission rate (MVER) exceeds 3 lbs. per 1,000 sq. ft. (1,36 kg per Health Product Declaration v1.0 - hpdcollaborative.org - Page 1 of 7

2 92,9 m2) per 24 hours, when using the anhydrous calcium chloride test (ASTM F1869). Do not install when the relative humidity (RH) of the concrete slab exceeds 75% (ASTM F2170). Use only when the substrate temperature is between 50 F and 90 F (10 C and 32 C), and when the ambient relative humidity is between 20% and 80%. Suitable Substrates Exterior-grade plywood and other approved wood underlayments (per flooring manufacturer recommendations) Concrete and properly prepared cement terrazzo Existing, properly prepared ceramic tile Cement-based self-leveling underlayments and patching compounds Planiseal EMB epoxy moisture-reduction barrier Planiseal WFM urethane moisture-reduction barrier Properly prepared, primed gypsum underlayments that meet the requirements for compressive strength according to ASTM F2419 Radiant-heat systems that have been properly installed Refer to MAPEI s Surface Preparation Requirements reference guide RGF0409 for floor-covering installation systems at Consult MAPEI s Technical Services Department for installation recommendations regarding substrates and conditions not listed. Surfa ce Prepa ration All substrates must be structurally sound, dry, solid and stable. Substrate should be clean and free of dust, dirt, oil, grease, paint, curing agents, concrete sealers, loosely bonded toppings, loose particles, old adhesive residues, and any other substance or condition that may prevent or reduce adhesion. Substrates must be flat to 3/16" in a 10-foot span (4,5 mm in a 3,05-meter span). Refer to wood flooring manufacturer s guidelines. Concrete and cement-based underlayments and patches must be fully cured and free of any hydrostatic and/or moisture problems. Use anhydrous calcium chloride tests to determine moisture vapor emission rates (MVER) according to ASTM F1869 or use moisture probe tests to determine RH according to ASTM F2170. Concrete slabs exceeding 3 lbs. (1,36 kg) of MVER or 75% RH should be treated with a moisture vapor reduction product. Refer to Technical Data Sheets at for information on these products. Use a moisture meter to check the RH of the wood flooring, surface of the substrate, and general jobsite area. Follow flooring manufacturer s guidelines. Mixing Note: Utilize all appropriate personal safety equipment during product use. Refer to Material Safety Data Sheet (MSDS) for more information. Ready to use; no mixing necessary Product Application 1. Read all installation instructions thoroughly before installation. 2. Select the appropriately notched trowel (see Approximate Product Coverage section). 3. Spread adhesive evenly over the subfloor, keeping the trowel at a 45 angle to the subfloor. 4. Only apply as much as can be installed within 45 minutes. 5. Install wood flooring in strict accordance with flooring manufacturer s written instructions. Health Product Declaration v1.0 - hpdcollaborative.org - Page 2 of 7

3 6. Adhesive transfer to the backing should be confirmed periodically by lifting the flooring material. Cleanup 1. Immediately clean any adhesive smudges from the flooring material s surface with Ultrabond Urethane Cleaner while the adhesive is still fresh/wet. Note: Ultrabond ECO 980 is extremely difficult to remove when cured. 2. Immediately clean tools with Ultrabond Urethane Cleaner while the adhesive is still fresh/wet. Protection Protect from light traffic for at least 12 hours. Protect from heavy traffic for at least 24 hours. Building owners should be advised of the wood flooring manufacturer s guidelines for climate control settings (temperature and humidity). These conditions must be monitored and kept constant to ensure the overall performance and long-term success of the installation. Product Performance Properties Laboratory Tests Results Polymer type Polyurethane Percent solids 100% VOC (Rule #1168 California s SCAQMD) 37 g/l Odor Light and sweet Trowelability Easy Density 13.8 lbs. per U.S. gal. (1,66 g per ml) Consistency Smooth paste Color Tan Shelf life 1 year when stored in original packaging at 73 F (23 C) Storage conditions 50 F to 90 F (10 C to 32 C) Flash point (Tag) > 200 F (93 C) Application Characteristics over Porous and Nonporous Substrates Wood Flooring Flash Time Working Time Adjustability Time At 50 F (10 C) and 80% RH 0 minutes 45 to 60 minutes 3 to 4 hours At 73 F (23 C) and 50% RH 0 minutes 45 to 60 minutes 2 to 3 hours At 100 F (38 C) and 20% RH 0 minutes 45 to 60 minutes 4 to 5 hours Flash time is the recommended amount of time for a freshly applied adhesive to remain exposed to the air before the installation of floor covering. Working time is the maximum amount of time an adhesive can remain exposed to the air and still effectively bond to the floor covering. Adjustability time is the window of time during which the floor covering can be repositioned without compromising the bond of the adhesive. Note: Working time may vary based on temperature, humidity, substrate porosity, trowel size and jobsite conditions. Packaging Product Code Size Metal pail: 3.5 U.S. gals. (13,2 L) Metal pail: 5 U.S. gals. (18,9 L) Protect containers from freezing in transit and storage. If frozen, material should not be stirred until it has completely thawed. Provide for heated storage on site and deliver all materials at least 24 hours before work begins. Approximate Product Coverages Flooring Type Typical Trowel Coverage* Cork underlayment 1/16" x 1/16" x 1/16" (1,5 x 1,5 x 1,5 mm) 125 to 185 sq. ft. per U.S. gal. (3,06 to 4,53 m2 per L) Finger block parquet 1/8" x 1/8" x 1/8" (3 x 3 x 3 mm) 70 to 80 sq. ft. per U.S. gal. (1,71 to 1,96 m2 per L) Wood flooring < 1/2" (12 mm) thick 3/16" x 5/32" (4,5 x 4 mm) Health Product Declaration v1.0 - hpdcollaborative.org - Page 3 of 7

4 45 to 55 sq. ft. per U.S. gal. (1,10 to 1,35 m2 per L) Wood flooring 1/2" to 5/8" (12 to 16 mm) thick 1/8" x 1/4" x 1/4" (3 x 6 x 6 mm) 40 to 50 sq. ft. per U.S. gal. (0,98 to 1,22 m2 per L) Wood flooring 3/4" (19 mm) thick 1/4" x 1/4" x 1/4" (6 x 6 x 6 mm) 30 to 40 sq. ft. per U.S. gal. (0,73 to 0,98 m2 per L) * Trowel dimensions are depth/width/space. Coverages shown are for estimating purposes only. Actual jobsite coverages may vary according to substrate conditions, type of trowel used and setting practices. Ul tr ab ond E C O We proudly support the following industry organizations: Ul tr ab o nd E C O Related Documents Reference Guide: Surface Preparation Requirements for floorcovering installation systems RGF0409* * At Refer to MAPEI s Material Safety Data Sheet (MSDS) for specific data related to VOCs, health and safety, and handling of product. Statement of Responsibility Before using, user shall determine the suitability of the product for its intended use and user alone assumes all risks and liability whatsoever in connection therewith. Any claim shall be deemed wa ived unless made in writing to us within fifteen (15) days from dat e it was, or reasonably should have been, discovered. MAPEI Headquarters of the Americas 1144 East Newport Center Drive Deerfield Beach, Florida Phone: US-MAPEI ( ) Technical Services (U.S. and Puerto Rico) (Canada) Customer Service MAPEI ( ) For the most current BEST-BACKED product data and warranty information, visit Edition Date: May 5, 2010 PR D_E10Evp 2010 MAPEI Corporation. All Rights Reserved. Printed in the USA. Release Date Expiry Date HPD URL oads/files/hpds/1023/ pdf Self-declared Second Party Third Party Certifier Certificate # SUMMARY DISCLOSURE The content of this product was assessed for health hazard warnings as required using Pharos Health Product Declaration v1.0 - hpdcollaborative.org - Page 4 of 7

5 Residuals Disclosure Measured 100 ppm (ideal) Measured 1000 ppm Predicted by process chemistry Full Disclosure of Intentional Ingredients Yes No Full Disclosure of Known Hazards Yes No Disclosure Notes please contact manufacturer for additional specifics As per MSDS (1,000 & 10,000 ppm) Not disclosed Other Contents in Descending Order of Quantity Unknown Hazards Highest concern GreenScreen score - unknown PBT (Persistent Bioaccumulative Toxic) Cancer Gene Mutation Development Reproductive Endocrine Respiratory Neurotoxicity Mammal Skin or Eye Aquatic toxicity Land toxicity Physical hazard Global warming Ozone depletion Multiple Unknown Total VOC Content Material (g/l) 0.00 Regulatory (g/l) Does the product contain exempt VOCs? N/A Yes No Are there VOC-free tints available? N/A Yes No Notes Certifications + Compliance VOC Emissions Not tested VOC Content Not tested Health Product Declaration v1.0 - hpdcollaborative.org - Page 5 of 7

6 The HPD Standard is solely a declaration of product content and direct health hazards associated with exposure to its individual contents. It is not a full assessment of environmental impacts from the life cycle of this product. It is not an assessment of risks associated with actual use of the product. It does not address the potential health impacts of substances used or created during manufacture that do not appear in the final product as residuals, nor substances created during combustion or other degradation processes. This Health Product Declaration was generated following the requirements of the noted Standard version and is valid for a total of three years after date of issue or three months after a substantive change of product contents occurs. Users should verify that this Health Product Declaration is compliant with the most current version of the HPD Standard. Accuracy of claims made in this Health Product Declaration is the sole responsibility of the listed manufacturer and certifier (if applicable). The HPD Collaborative does not warrant any claim made herein, explicit or implicit. The HPD Standard is an open standard developed and managed by the HPD Collaborative, a nonprofit organization. For more information, visit hpdcollaborative.org. CONTENT IN DESCENDING ORDER OF QUANTITY All ingredients must be assessed for health warnings against Priority Hazard Lists, regardless of disclosure level. Priority Hazard Lists and information on the GreenScreen Benchmarks can be found at GS: GreenScreen Benchmark; RC: Recycled Content, PC: Post Consumer, PI: Post Industrial (Pre-consumer), BO: Both; Nano: comprised of nanoscale particles or nanotechnology Name CAS RN % weight GS RC Nano Role Hazard A Hazard B Hazard C Hazard D Hazard E Warning A Warning B Warning C Warning D Warning E Notes Unknown Unknown 0-10 % N N Adhesive Unknown Not disclosed by supplier Please contact manufacturer for further information CERTIFICATIONS AND COMPLIANCE Certifying Party = First: Manufacturer s self-declaration; Second: Verification by trade association or other interested party; Third: Verification by independent certifier (ideal). Applicable facilities = Manufacturing sites to which testing applies. Type Standard or Certification Certifier or Laboratory Certifying Party Issue Date Expiry Date Certificate URL Applicable Facilities Notes VOC Emissions N/A VOC Content Not tested Health Product Declaration v1.0 - hpdcollaborative.org - Page 6 of 7

7 Recycled Content Not tested Other ACCESSORY MATERIALS This section is for additional products required by warranty or recommended by the manufacturer for installation (such as adhesives, fasteners, or factory coatings) or for maintenance, cleaning, or operations. Refer to Health Product Declarations, published separately, for a complete view of these products. Note: This declaration is not intended to address hazards of the installation process. Required or Recommended Product URL for Companion Health Product Declaration Condition when required or recommended and/or other notes NOTES Health Product Declaration v1.0 - hpdcollaborative.org - Page 7 of 7