HURRICANESHIELD IMPACT-RESISTANT GLASS Section Directory. Size and performance summary. Glazing performance. Grille profiles and patterns.

Size: px
Start display at page:

Download "HURRICANESHIELD IMPACT-RESISTANT GLASS Section Directory. Size and performance summary. Glazing performance. Grille profiles and patterns."

Transcription

1 HURRICANESHIELD IMPACT-RESISTANT GLASS Section Directory Size and performance summary Glazing performance Grille profiles and patterns Size tables Design Data Detailed Product Description Cross sections The information published in this document is believed to be accurate at the time of publication. However, because we are constantly working to improve our products, specifications are subject to change without notice. Consult your local Pella representative for up-to-date product information. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-1

2 HURRICANESHIELD IMPACT-RESISTANT GLASS Product Summary Pella 350 Series Sliding Patio Doors feature extruded, high impact-resistant rigid PVC (polyvinyl chloride) frames and panels with heat-fused mitered corners for a fully welded corner assembly and SmoothSeam virtually invisible welds. Panels are reinforced with extruded aluminum in all stiles and rails. The doors meet or exceed industry standards for water infiltration and wind resistance. NAIL FIN FRAME DESIGN - 1" setback for 4-15/16" wall depth - 1-3/8" setback for 4-9/16" wall depth Continuous fin with welded corners adds a protective weather barrier and allows for hassle-free installation. The standard 6" frame depth includes interior and exterior accessory grooves. Custom sizes are available in 1/8" increments for a perfect fit. Available with 1" HurricaneShield Impact-Resistant Low-E insulating glass or 7/16" Single laminated Impact-Resistant glass. BLCK FRAME 6" Frame Depth Block frame can be used in new construction block or concrete walls. Block frame may also be used in replacement of old aluminum or steel frame patio doors without removing the existing frame. Frame and wall depth are 6" and includes interior and exterior accessory grooves. Custom sizes are available in 1/8" increments for a perfect fit. Available with 1" HurricaneShield Impact-Resistant Low-E insulating glass or 7/16" Single laminated Impact-Resistant glass. 1" Fin Setback 1-3/8" Fin Setback Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-2

3 Product Selection Guide Size and Performance Data PELLA 350 SERIES SIZES Standard Sizes 1 Special Sizes Available Built on 1/8" Increments Frames Nail Fin - 1-3/8" setback for 4-9/16" Wall Depth Nail Fin - 1" setback for 4-15/16" Wall Depth Block Frame - 6" Frame Depth S S S S PERFRMANCE 2 Meets or Exceeds AAMA/WDMA Ratings SGD-LC50-LC65 Hallmark Certified Air Infiltration (cfm/ft 2 of 1.57 psf wind pressure) Design Pressure psf Water Resistance psf Forced Entry 4 Grade 10 Maximum perating Force (lbs) (Initiate Motion / Maintain Motion) 30/20 S = Standard; = ptional (1) See size charts in this section for available sizes. (2) Published performance data is for single unit only. All products must be installed in separate openings. The presence of low-e or argon have negligible effect on sound attenuation characteristics. Product Vent Units 2-panel (X/X) and 3-panel (X) Vent Units 4-panel (XX) Fixed Units () Miami-Dade County Certified 1 Florida Product Approval System 2 Hallmark Certified Design Pressure NA Design Pressure FPAS 7/16" - IMPACT RESISTANT SINGLE-LAMINATED SGP +/-50 to +/ /-50 to +/-75 FL H-1180, 81 1" - IMPACT RESISTANT INSULATED GLASS SGP +/-50 to +/ /-50 to +/-75 FL H /16" - IMPACT RESISTANT SINGLE-LAMINATED SGP +/-50 FL H " - IMPACT RESISTANT INSULATED GLASS SGP +/-50 FL H /16" - IMPACT RESISTANT SINGLE-LAMINATED SGP +/-50 to +/-75 FL H-1180, 81 1" - IMPACT RESISTANT INSULATED GLASS SGP +/-50 to +/-75 FL H-1180, 81 ( ) = Not Applicable; (P) = Pending (1) Units are tested for air/water/structural and impact-resistance, and certified for wind zone 4, large missile rating D. (2) Units are tested for air/water/structural and impact-resistance, and certified for wind zone 3, large missile rating C. Not approved for use in Miami-Dade County, Florida. Florida Product Approval System number not needed if Miami-Dade County certified. For clear opening, vent area, visible glass, and frame area see Design Data pages. (3) Published performance Data for air infiltration is determined by testing a minimum of four (4) products of NFRC model size. Testing is conducted in accordance with ASTM E283. Air infiltration ratings for products will differ by size. The performance data does not apply to combination assemblies unless notes. Actual product performance may vary for a number of reasons including installation and product care. (4) The higher the level, the greater the product's ability to resist forced entry. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-3

4 Product Selection Guide Features and ptions GLAZING (HURRICANESHIELD IMPACT-RESISTANT) Insulating Glass PELLA 350 SERIES 1" Advanced Low-E with Argon S 1" Advanced Low-E (High Altitude nly) 1" SunDefense Low-E (High Altitude nly) 1" SunDefense Low-E with Argon 1" Gray Low-E (High Altitude nly) 1" Gray Low-E with Argon 1" Bronze Advanced Low-E (High Altitude nly) 1" Bronze Advanced Low-E with Argon Single Glass 7/16" Laminated Clear 7/16" Laminated SunDefense Low-E 7/16" Laminated Bronze Tint 7/16" Laminated Gray Tint INTERIR / EXTERIR CLR White Interior/White Exterior Almond Interior/Almond Exterior White Interior/Brown Exterior White Interior/Fossil Exterior White Interior/Black Exterior White Interior/Brick Red Exterior White Interior/Hartford Green Exterior White Interior/Morning Sky Gray Exterior White Interior/Poplar White Exterior White Interior/Portobello Exterior White Interior/Tan Exterior GRILLES-BETWEEN-THE-GLASS 1 Grille Profiles 3/4" Contour 1" Contour Grille Patterns Traditional 9-Lite Prairie 6-Lite Prairie Top Row Custom - Equally Divided SCREENS Conventional Fiberglass Sliding Screen No Screen DR HANDLE FINISHES Color matched to frame Keyed Lock Additional Interior Finishes (Bright Brass, Satin Nickel, il-rubbed Bronze) S S S S S = Standard; = ptional (1) Not available with 7/16" Single-Laminate Glazing. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-4

5 Glazing Performance - Total Unit Glass Thickness Type of Glazing NFRC Certified Product # Glass (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 SHGC VLT CR Shaded Areas Meet ENERGY STAR Performance Criteria in Zones Shown U. S. Canada 2 Zone ER Zone INSULATING GLASS N NC SC S " Advanced Low-E IG PVB PEL-N air with 3/4" or 1" grilles-between-the-glass PEL-N " Advanced Low-E IG PVB PEL-N argon with 3/4" or 1" grilles-between-the-glass PEL-N " SunDefense Low-E IG PVB PEL-N air with 3/4" or 1" grilles-between-the-glass PEL-N " SunDefense Low-E IG PVB PEL-N argon with 3/4" or 1" grilles-between-the-glass PEL-N TINTED INSULATING GLASS 1" Bronze Advanced Low-E IG PVB PEL-N air with 3/4" or 1" grilles-between-the-glass PEL-N " Bronze Advanced Low-E IG PVB PEL-N argon with 3/4" or 1" grilles-between-the-glass PEL-N " Grey Low-E IG PEL-N air with 3/4" or 1" grilles-between-the-glass PEL-N " Grey Low-E IG PEL-N argon with 3/4" or 1" grilles-between-the-glass PEL-N SINGLE LAMINATED GLASS 7/16" Clear PVB PEL-N NA NA /16" SunDefense PVB PEL-N NA NA /16" Bronze Tint PVB PEL-N NA NA /16" Gray Tint PVB PEL-N NA NA R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY STAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY STAR 2015 initiative. Based on unit size, some products will use 2.5mm glass that may have improved glazing performance from what is shown. See the Product Performance section for more detailed information or visit for Energy Star guidelines. Sound Transmission Class and utdoor-indoor Transmission Class Product 2- Panel Sliding Door Frame Size Tested 3 verall Glazing Thickness Glazing System Exterior Glass Thickness Interior Glass Thickness Third Pane Thickness (HGP) STC Rating ITC Rating 71-3/8" x 81-1/2" 1" 5mm 12mm (3) ASTM E 1425 defines standard sizes for acoustical testing. Ratings achieved at that size are representative of all sizes of the same configuration. The presence of low-e or argon have negligible effect on sound attenuation characteristics. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-5

6 Grille Types Grille Profiles GRILLES-BETWEEN-THE-GLASS HURRICANESHIELD Grilles-Between-the-Glass Impact-Resistant Glazing Simulated Divided Light 3/4" 1" 7/8" Appearance of exterior grille color will vary depending on Low-E glass coating. 3/4" Contour GBG 1" Contour GBG 7/8" SDL Grille Patterns PRAIRIE PATTERNS 6-Lite Prairie - Approximately 6" from edge of panel to center of bar. 9-Lite Prairie - Approximately 6" from edge of panel to center of bar. 6-Lite Prairie 9-Lite Prairie ther Available Patterns Traditional - Specify number of lites in each panel wide and high. - Grille bars must be equally divided on visible glass. - Minimum 6" x 6" center-to-center. Top Row - Top Row dimension must be 1/2 actual glass. Traditional Top Row Custom Equally Divided Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-6

7 Special Sizes DRS MINIMUM 46-1/2"W x 70-1/2"H (1 181 x 1 791) MAXIMUM 95-1/2" W x 95-1/2" H (2 426 x 2 426) MINIMUM 71-1/2"W x 70-1/2"H (1 816 x 1 791) MAXIMUM 143-1/2" W x 95-1/2" H (3 645 x 2 426) MINIMUM 95-1/2"W x 70-1/2"H (2 426 x 1 791) MAXIMUM 143-1/2"W x 95-1/2" H (3 645 x 2 426) SIDELIGHTS TRANSMS MINIMUM 18-1/8"W x 70-1/2"H (460 x 1 791) MAXIMUM 47-1/2" W x 95-1/2" H (1 207 x 2 426) MINIMUM 46-1/2"W x 18-1/8"H (1 181 x 460) MAXIMUM 95-1/2" W x 47-1/2" H (2 426 x 1 207) General Notes: Special sizes are available within the parameters shown on 1/8" increments. To convert areas to square meters (m2), multiply square feet by Miscellaneous Formulas DRS TRANSMS / SIDELIGHTS PANEL ACTUAL GLASS VISIBLE GLASS Panel Height = FH " X / X Panel Width = FW/ " X Panel Width = FW/3-0.25" XX Panel Width = FW/ " Glass Height = FH " X / X Glass Width = FW/ " X Glass Width = FW/ " XX Glass Width = FW/ " VG Height = FH " X / X VG Width = FW/2-6.5" X VG Width = FW/ " XX VG Width = FW/ " PANEL ACTUAL GLASS VISIBLE GLASS Panel Height = FH " Panel Width = FW " Glass Height = FH " Glass Width = FW " VG Height = FH " VG Width = FW " CLEAR PENING Height With 3/8" Sill Riser = FH " With 1" Sill Riser = FH " X / X Clear pening Width = FW/ " X Clear pening Width = FW/ " XX Clear pening Width = FW/ " CLEAR PENING Not Applicable To convert areas to square meters (m 2 ), multiply square feet by Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-7

8 Size Tables Transoms, Fixed and 2-panel Transoms (1 524) (1 511) (1 829) (1 816) (2 286) (2 273) (2 438) (2 426) pening Frame 5' 0" 59 1/ 2" 6' 0" 71 1/ 2" 7' 6" 89 1/ 2" 8' 0" 95 1/ 2" 2' 0" 1/ 2" 23 (610) (597) 5-0/ / / /2-0 Sidelights (762) (749) (843) (830) (914) (902) (995) (983) (1 219) (1 207) pening Frame 2' 6" 29 1/ 2" 2' 9 3 / 16" / 16" 3' 0" 35 1/ 2" 3' / 16" 11 / 16" 4' 0" 47 1/ 2" 6' 8" (2 032) 6' 7 11 / 16 " (2 024) 8' 0" (2 438) 6' 10" (2 083) 3 / 16" (2 011) 95 1 / 2" (2 426) 81 1/ 2" (2 070) 79 1/ 2 " (2 019) / / / / / / / / / / / / / / / Panel (X ) pening (2 032) 6' 8" (2 083) 6' 10" (2 438) 8' 0" Frame (2 019) 1 / 2" (2 426) 81 1/ 2" (2 070) 79 1/ 2 " 95 1 (1 524) (1 511) 5' 0" 59 1/ 2" (1 829) (1 816) 6' 0" 71 1/ 2" (2 438) (2 426) 8' 0" 95 1/ 2" 5-0/ / / / / / / / / / / / / /8-0 Scale 1/8" = 1' 0" 350 Series patio doors do not have mulling capabilities. All products must be installed in separate openings. All doors, transoms and sidelights with double-pane insulated glass are glazed with tempered glass, single-pane laminated glass is not tempered. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-8

9 Size Tables 3 and 4-Panel 3-Panel (X) (2 286) (2 273) (2 345) (2 332) (2 743) (2 731) (2 802) (2 789) (3 658) (3 645) pening Frame 7' 6" 89 1/ 2" 7' / 16" 13 / 16" 9' 0" 9' 2 5 / 16" 12' 0" / 2" / 16" 143 1/ 2 " (2 032) (2 019) 8' 0" (2 438) 6' 10" (2 083) 6' 8" 95 1 / 2" (2 426) 81 1/ 2" (2 070) 79 1/ 2 " 7-6/ / / / / / / / / / / / / / /8-0 4-Panel (XX) pening (3 026) (3 013) 9' 11 1/ 8" (3 048) (3 035) 10' 0" (3 635) (3 623) 1/ 8" Frame / 8" / 2" / 8" 143 1/ 2" 11' 11 (3 658) (3 645) 12' 0" (2 032) (2 019) 8' 0" (2 438) 6' 10" (2 083) 6' 8" 95 1 / 2" (2 426) 81 1/ 2" (2 070) 79 1/ 2 " 9-11/ / / / / / / / / / / /8-0 Scale 1/8" = 1' 0" (1) X" indicates venting or sliding panel and " indicates fixed panel as viewed from the exterior. Doors shown as X are also available as X. 350 Series patio doors do not have mulling capabilities. All products must be installed in separate openings. All doors, transoms and sidelights with double-pane insulated glass are glazed with tempered glass, single-pane laminated glass is not tempered. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-9

10 Design Data 2-, 3-, and 4-Panel PELLA 350 SERIES HURRICANESHIELD IMPACT-RESISTANT Call ut Width (Inches) Frame X/X VENTING UNITS Height (Inches) Clear pening Width (Inches) Height 3 (Inches) Design Pressure (Structural nly) Florida Product Approval Systems (FPAS) 2 Miami -Dade Approved (NA) Performance Class & Grade 1 5-0/ /2 79-1/2 21-1/8 74-3/4 +75/-75 FL LC50 / LC65 6-0/ /2 79-1/2 27-1/8 74-3/4 +75/-75 FL LC50 / LC65 8-0/ /2 79-1/2 39-1/8 74-3/4 +75/-75 FL LC50 / LC65 5-0/ /2 81-1/2 21-1/8 76-3/4 +75/-75 FL LC50 / LC65 6-0/ /2 81-1/2 27-1/8 76-3/4 +75/-75 FL LC50 / LC65 8-0/ /2 81-1/2 39-1/8 76-3/4 +75/-75 FL LC50 / LC65 5-0/ /2 95-1/2 21-1/8 90-3/4 +50/-50 FL LC50 6-0/ /2 95-1/2 27-1/8 90-3/4 +50/-50 FL LC50 8-0/ /2 95-1/2 39-1/8 90-3/4 +50/-50 FL LC50 X VENTING UNITS 7-6/ /2 79-1/2 20-3/8 74-3/4 +75/-75 FL LC50 / LC65 7-8/ / /2 21-1/8 74 3/4 +75/-75 FL LC50 / LC65 9-0/ /2 79-1/2 26-3/8 74-3/4 +75/-75 FL LC50 / LC65 9-2/ / /2 27-1/8 74-3/4 +75/-75 FL LC50 / LC / /2 79-1/2 38-3/8 74-3/4 +75/-75 FL LC50 / LC65 7-6/ /2 81-1/2 20-3/8 76-3/4 +75/-75 FL LC50 / LC65 7-8/ / /2 21-1/8 76 3/4 +75/-75 FL LC50 / LC65 9-0/ /2 81-1/2 26-3/8 76-3/4 +75/-75 FL LC50 / LC65 9-2/ / /2 27-1/8 76-3/4 +75/-75 FL LC50 / LC / /2 81-1/2 38-3/8 76-3/4 +75/-75 FL LC50 / LC65 7-6/ /2 95-1/2 20-3/8 90-3/4 +50/-50 FL LC50 7-8/ / /2 21-1/8 90 3/4 +50/-50 FL LC50 9-0/ /2 95-1/2 26-3/8 90-3/4 +50/-50 FL LC50 9-2/ / /2 27-1/8 90-3/4 +50/-50 FL LC / /2 95-1/2 38-3/8 90-3/4 +50/-50 FL LC50 SPECIAL SIZE X/X AND X VENTING UNITS All doors 83-1/2 +75/-75 FL LC50 / LC65 All doors > 83-1/2 +50/-50 FL LC50 XX VENTING UNITS 9-11/ /8 79-1/2 38-1/8 74 3/4 +75/-75 FL14189 LC50 / LC / /2 79-1/2 38-1/4 74 3/4 +75/-75 FL14189 LC50 / LC / /8 79-1/2 49-7/8 74 3/4 +75/-75 FL14189 LC50 / LC / /2 79-1/2 50-1/4 74 3/4 +75/-75 FL14189 LC50 / LC / /8 81-1/2 38-1/8 76 3/4 +75/-75 FL14189 LC50 / LC / /2 81-1/2 38-1/4 76 3/4 +75/-75 FL14189 LC50 / LC / /8 81-1/2 49-7/8 76 3/4 +75/-75 FL14189 LC50 / LC / /2 81-1/2 50-1/4 76 3/4 +75/-75 FL14189 LC50 / LC / /8 95-1/2 38-1/8 90 3/4 +50/-50 FL14189 LC / /2 95-1/2 38-1/4 90 3/4 +50/-50 FL14189 LC / /8 95-1/2 49-7/8 90 3/4 +50/-50 FL14189 LC / /2 95-1/2 50-1/4 90 3/4 +50/-50 FL14189 LC50 ( ) Not Available (1) All performance ratings are for single units only and are Hallmark Certified. LC50 units will have a 3/8" sill riser and all LC65 units have a 1" sill riser. All vent sizes and glass types are tested for air/ water/structural and impact-resistance, and are certified for wind zone 4, large missile rating D. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors (2) Florida Product Appoval System number not needed if Miami-Dade certified. To convert areas to square meters (m2), multiply square feet by V350-SPD-HIG-10

11 Design Data Sidelights and Transoms PELLA 350 SERIES HURRICANESHIELD IMPACT-RESISTANT Call ut SIDELIGHTS Width (Inches) Frame Height (Inches) Clear pening Width (Inches) Height 3 (Inches) Design Pressure (Structural nly) Florida Product Approval Systems (FPAS) 2 Miami -Dade Approved (NA) Performance Class & Grade 1 2-6/ /2 79-3/16 +75/-75 FL14189 LC50 / LC65 2-9/ / /16 +75/-75 FL14189 LC50 / LC65 3-0/ /2 79-3/16 +75/-75 FL14189 LC50 / LC65 3-3/ / /16 +75/-75 FL14189 LC50 / LC65 4-0/ /2 79-3/16 +75/-75 FL14189 LC50 / LC65 2-6/ /2 79-1/2 +75/-75 FL14189 LC50 / LC65 2-9/ / /2 +75/-75 FL14189 LC50 / LC65 3-0/ /2 79-1/2 +75/-75 FL14189 LC50 / LC65 3-3/ / /2 +75/-75 FL14189 LC50 / LC65 4-0/ /2 79-1/2 +75/-75 FL14189 LC50 / LC65 2-6/ / /2 +75/-75 FL14189 LC50 / LC65 2-9/ / /2 +75/-75 FL14189 LC50 / LC65 3-0/ / /2 +75/-75 FL14189 LC50 / LC65 3-3/ / /2 +75/-75 FL14189 LC50 / LC65 4-0/ / /2 +75/-75 FL14189 LC50 / LC65 2-6/ / /2 +50/-50 FL14189 LC50 2-9/ / /2 +50/-50 FL14189 LC50 3-0/ / /2 +50/-50 FL14189 LC50 3-3/ / /2 +50/-50 FL14189 LC50 4-0/ / /2 +50/-50 FL14189 LC50 TRANSMS 5-0/ /2 23-1/2 +75/-75 FL14189 LC50 / LC65 6-0/ /2 23-1/2 +75/-75 FL14189 LC50 / LC65 7-6/ /2 23-1/2 +75/-75 FL14189 LC50 / LC65 8-0/ /2 23-1/2 +75/-75 FL14189 LC50 / LC65 9-0/ /2 23-1/2 +75/-75 FL14189 LC50 / LC65 SPECIAL SIZE SIDELIGHTS AND TRANSMS All units 83-1/2 +75/-75 FL14189 LC50 / LC65 All units > 83-1/2 +50/-50 FL14189 LC50 ( ) Not Available (1) All performance ratings are for single units only and are Hallmark Certified. LC50 units will have a 3/8" sill riser and all LC65 units have a 1" sill riser. All vent sizes and glass types are tested for air/ water/structural and impact-resistance, and are certified for wind zone 4, large missile rating D. (2) Florida Product Appoval System number not needed if Miami-Dade certified. To convert areas to square meters (m2), multiply square feet by Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-11

12 Detailed Product Descriptions FRAME verall frame depth: 6". Frame members are mitered and heat fused to provide a fully welded corner assembly. Sill is fitted with weeps. Frame: [1-3/8" setback nail fin for 4-9/16" wall depth] [1" setback nail fin for 4-15/16" wall depth] [Block frame for 4-15/16" wall depth]. Interior and exterior frame surfaces are extruded rigid PVC. DR PANELS Door Panel consists of extruded rigid PVC. Panel members are mitered and heat-fused to provide a fully welded corner assembly. Vent panel is fully operable for ventilation. Vent panels have two adjustable rollers, set on a stainless steel track cap. Contains sealed impact resistant glazing. WEATHERSTRIPPING Fin-type pile around perimeter of vent panel. GLAZING SYSTEM Quality fully-tempered float glass complying with ASTM C Impact Resistant Silicone-glazed 1" dual-seal impact-resistant insulating glass SGP. Laminated clear interior light. Tempered exterior light is [Advanced Low-E coated with argon] [SunDefense Low-E coated with argon] [Bronze Advanced Low-E coated with argon] [Gray Low-E coated with argon] [bscure 2] [High Altitude 1]. - or - Silicone-glazed 7/16" [SGP Low-E] [SGP] laminated glass [clear] [bronze] [gray] [SunDefense Low-E coated]. INTERIR / EXTERIR Window frame and sash members are [[White] [Almond] with integral color extruded throughout the profiles] [[Brown] [Black] [Brick Red] [Hartford Green] [Morning Sky Gray] [Poplar White] [Portobello] [Tan] [Fossil] exterior, consisting of a solar reflective coating exceeding AAMA 613 test requirements, with White integral color extruded throughout the profiles on the interior]. All exposed PVC surfaces are smooth, glossy and uniform in appearance. HARDWARE Interior handle and thumblock; finish is [White] [Almond] [Bright Brass] [Satin Nickel] [il-rubbed Bronze]. Exterior handle; finish matches exterior finish. Keylock with K-keyway cylinder. Finish is [Chrome]. All fasteners are a corrosion-resistant material compatible with PVC. Multi-point lock, [electroplated steel] [stainless steel]. Door rollers are adjustable, permanently-sealed, [electroplated steel with organic coated ball-bearing rollers] [corrosion resistant stainless steel, ball bearing rollers]. SCREEN Full-size with black vinyl coated 18/14 mesh fiberglass screen cloth complying with ASTM D 3656 and SMA 1201 set in an extruded aluminum frame. Supplied with four self-adjustable rollers, latch and latch handle. Frame of screen matches exterior frame color. PTINAL PRDUCTS Grilles Grilles-Between-the-Glass Insulating glass contains [3/4"] [1"] contoured aluminum grilles permanently installed between two panes of glass. Patterns are [Traditional] [6-Lite Prairie] [9-Lite Prairie] [Top Row] [Custom Equally Divided]. Interior grille color matches interior frame. Exterior grille color [3/4" Grille is [White] [Almond 3] [Brown] [Black] [Brick Red] [Hartford Green] [Morning Sky Gray] [Poplar White] [Portobello] [Tan] [Fossil]] [1" Grille is [White] [Almond 3] [Brown]]. (1) Available in High Altitude without Argon. (2) bscure glass not available with Bronze Advanced Low-E or IG. (3) Almond grilles only available on almond units. Almond units with grilles will have an almond grille color. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-12

13 Unit Sections Frame Types verview NEW CNSTRUCTIN FRAME 1 3/8" FIN SET BACK 1 3/8" [35] [116] GLAZING PTINS 1" LAMINATED IG 6" AW 1" [25] 4 15/16" [125] 6" AW 3/8" [10] [90] 1" [25] 1 5/16" [33] [90] 1 5/16" [33] [90] 1 5/16" [33] 1" FIN SET BACK 7/16" SINGLE LAMINATED IG REPLACEMENT FRAME DESIGN BLCK FRAME SILL RISER PTINS 1" RISER 3/8" RISER Scale 3" = 1' 0" 350 Series patio doors do not have mulling capabilities. All products must be installed in separate openings. LC50 units will have a 3/8" sill riser and all LC65 units have a 1" sill riser. All dimensions are approximate. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-13

14 Unit Sections 1-3/8" Fin Setback 5 15/16" [151] XH H ptional 1" SILL RISER ptional 3/8" SILL RISER 1 5/16" [33] 1" [25] 1 5/16" [33] LJ I FJ FRAME HEIGHT FRAME HEIGHT 3/8" [9] 1 3/8" [35] 5 15/16" [151] [116] 1 5/16" [33] 4 7/8" [124] XH VENT HEAD H FIXED HEAD XS S XS VENT SILL S FIXED SILL 1 3/8" [35] [116] LJ LCK JAMB I INTERLCKER FJ FIXED JAMB 4 3/4" [120] 1 1/8" [29] FRAME WIDTH Scale 3" = 1' 0" 350 Series patio doors do not have mulling capabilities. All products must be installed in separate openings. All dimensions are approximate. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-14

15 X FJ FIXED JAMB MS I INTERLCKER FJ FIXED JAMB MEETING STILE 1 1/8" [29] [115] [115] 4 11/16" [120] FRAME WIDTH FJ MS FJ FJ MX FJ FLR LINE X XX XX FJ FIXED JAMB I INTERLCKER MX INTERLCKER FJ FIXED JAMB MEETING STILE 4 1/16" [103] [115] [115] 4 11/16" [120] FRAME WIDTH I I I I Unit Sections 1-3/8" Fin Setback [116] 5 15/16" [151] 1 3/8" [35] 1 1/8" [29] Scale 3" = 1' 0" 350 Series patio doors do not have mulling capabilities. All products must be installed in separate openings. All dimensions are approximate. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-15

16 Unit Sections 1-3/8" Fin Setback 5 15/16" [151] SH SJ 4 11/16" [120] SH SIDELIGHT HEAD SJ SIDELIGHT JAMB SS FRAME HEIGHT 5 15/16" [151] SS SIDELIGHT SILL 4 11/16" [120] 1 1/8" [29] 1 1/4" [32] FRAME WIDTH 1 1/8" [29] TH 1 3/8" [35] [116] TJ TS [90] TH TRANSM HEAD TJ TRANSM JAMB FRAME HEIGHT 1 3/8" [35] [116] [90] TS 4 11/16" [120] 1 1/8" [29] 1 1/8" [29] FRAME WIDTH TRANSM SILL Scale 3" = 1' 0" 350 Series patio doors do not have mulling capabilities. All products must be installed in separate openings. All dimensions are approximate. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors V350-SPD-HIG-16