Custom Home Design Plan #204 Summit By SDS-CAD Specialized Design Systems

Size: px
Start display at page:

Download "Custom Home Design Plan #204 Summit By SDS-CAD Specialized Design Systems"

Transcription

1 BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. BUILD AS PER IRC, UBC OR CURRENT LOCAL CODE REQUIREMENTS Custom Home Design Plan #204 Summit By Page 1 Page 2 Page Page 4 Page 5 Page 6 Page Cover Page Main Floor Plan Foundation Plan Elevation Plan Framing Plan Electrical Plan Misc Details To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made on them after prints are made will be done at the owner's and / or builder's expence and responsibility. The contractor shall verify all dimensions and enclosed drawing. SCAD is not liable for errors once construction has begun. While every affort has been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of the job must check all dimensions and other details prior to construction and be solely responsible thereafter. All calculations and member sizing should be verified for your building by a certified building official. P O Box 4 Mendon, Utah SCAD 1

2 Range Hoods All Bath Fans Dryer Vent VENTING SCHEDULE Vent Through Roof Vent to Exterior Vent to Exterior INSULATION SCHEDULE Ceilings Wall above grade Wall interior below grade R-8 Min R-19 Min R-1 Min WINDOW SCHEDULE NUMBER QTY SIZE DIMENSIONS DESCRIPTION W "X6" DOUBLE HUNG W "X6" LEFT SLIDING W "X4 LEFT SLIDING W04 4X4 LEFT SLIDING W "X116" MULLED UNIT W X80" MULLED UNIT DOOR SCHEDULE NUMBER QTY SIZE DIMENSIONS DESCRIPTION D X96" GARAGE 4-PANEL GARAGE DOOR D X80X1 / PANEL DOOR - COLOR BRITE WHITE D X80" BIFOLD D X80X1 / PANEL DOOR - COLOR BRITE WHITE D X80X1 / POCKET PANEL DOOR - COLOR BRITE WHITE D X80X1 /4" 6-PANEL D X80X1 /4" EXT. PANEL DOOR - COLOR BRITE WHITE D X80" BIFOLD D X80X1 / PANEL DOOR - COLOR BRITE WHITE D X80X1 /4" EXT. 6-PANEL D /16X80X1 / PANEL DOOR - COLOR BRITE WHITE D X80X1 / PANEL DOOR - COLOR BRITE WHITE ELECTRICAL SCHEDULE NUMBER QTY DESCRIPTION E V E02 5 DUPLEX E0 2 DUPLEX (WEATHERPRO) - COLOR LIGHT GRAY (MATTE) E04 EXHAUST E05 GFCI E06 HALF CONE - LIGHTING GREY E0 26 HALF DOME LIGHT - LIGHTING GREY E08 5 PORCH LANTERN E09 14 SINGLE POLE E10 4 SMOKE DETECTOR E11 16 THREE WAY 52'-4" 10'-4" 9'-" 8'-6" 2'-11" 1'-" 1'-9" '-4" 4'-1" '-0" 2'-6" '-0" '- 4'-0" 8'-" 068 PORCH 9'-5" x 19'-5" 10'-0" 0X22 CRAWL 8'-2" FAU A WH A 5'-6" D/W 9'-0" LAUNDRY 10'- x 6'-6" " '-0" GARAGE 26'-4" x 2'-" KITCHEN 16'-0" x 20'-9" 068 0X22 ATTIC 6'-" 068 '-0" 22'-4" 4'-11" '-0" BATH 4'-11" x 6'-6" '- 5'-11" 2'-10" '-6" 5'-0" 2'-1" 4'-0" 6'-" ENTRY 6'-4" x 11'-9" 2'-10" ' Tall Entry '-10" LIVING 16'-" x 29'-5" 2'-6" 5'-4" 4'-0" '-0" '-0" 2'-0" A 2'-1" BEDROOM 11'-4" x 11'-" 6'-9" 2'-4" 1868 CLOSET 6'-" x 6'-6" '-2" 11' ' '-0" A MASTER BDRM 16'-0" x 14'-1" A 2'-6" '-0" 10'-2" 11'-4" BATH 11'-" x 5'-0" BEDROOM 11'-5" x 11'-0" '-0" 5068 '-1" 5'-2" 4'- WALK IN SHOWER/TUB LINEN 4'-1" 6" 4'-0" 5'-6" 4'-0" 6" 2'-1" 11'- 2'-5" 5'-5" 14'-6" '-2" 45'-4" P O Box 4 Mendon, Utah sdscad@pcu.net A 9080 A 9080 A '-0" 9'-0" '-0" 9'-0" '-0" 10 1/2" 4'-5" 1'- 1/2" 2'-10" 4'-0" 2'-10" '-11" 4'-0" '-11" 2'-0" 2'-" 6'-" 2'- 9'- 11'-10" MAIN FLOOR PLAN SCALE SCAD 2

3 Concrete: 1. All slabs are to be 4" concrete over 4" gravel unless otherwise noted on the plans. 2. Concrete to be ACI 01-66, Type II cement, 2500 psi at 28 days, 5" maximum slump.. Reinforcing to be ASTM A615-Bars with Fy=60 ksi lamp 0 diameter minimum at splices or weld per ACI Std. 4. Concrete design based on Fc 2000 psf, Fc 2500 psi for quality only. 5. Anchor bolts shall be A-0 embedded " minimum into concrete or masonry grout. 16'- 16'- 1'-0" BRACED WALLS AND ALT BRACED WALL A OPTIONS Brace all exterior walls and cross-stud partitions at each end of building and at least every 25' of length by one of the following: a. Simpson WB 126 wall bracing with -16d nails at each end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of /8 inch. c. Continuous bracing from floor to floor SINGLE POUR RIM JOIST INSTALLATION Simpson HPAHD strap location marker HOUSE WALLS DECKS & PORCHES BEARING WALL GARAGE WALL See detail for cantilever FOOTING SCHEDULE SEE FOOTNOTE NO.5 NAILED PORTION 1 1/2" 20" x 10" Min 1 x 10" Min 20" x 10" Min 1 x 10" Min Min 2 #4 Rebar Horizontal on undisturbed or compacted soil HD1 = HPAHD22 Simpson Hold Downs HD2 = STHD14RJ Simpson Hold Downs SINGLE POUR INSTALLATION ONE #4 REBAR IN SHEAR CONE 12" MINIMUM REBAR LENGTH 52'-4" 19'-11" 8'-6" 2'-11" S S 10'-0" Block out for garage doors see floor plan for locations Bearing wall for crawl space construction Vent crawl space adequately as per code with vents thru foundation wall 6'-9" 2'-4" Bearing wall for crawl space construction 2'-1" 41'-2" 4'-" P O Box 4 Mendon, Utah sdscad@pcu.net 1/2" MIN. FROM ONE #4 REBAR IN SHEAR CONE Simpson Strong-Tie HPAHD 0" MINIMUM REBAR LENGTH DISTANCE FROM EDGE STRAP TO Simpson Strong-Tie HPAHD 2'-0" 11'-10" 9'- 11'-10" FOUNDATION PLAN SCALE SCAD

4 P O Box 4 Mendon, Utah sdscad@pcu.net RIGHT ELEVATION ARCHITECTURAL ASHPHALT SHINGLES 8/12 PITCH Exterior Finish to be determined by contractor/homeowner and to meet subdivision requirements REAR SCAD REVISIONS 10" '-0" 9'-0" 15'-1" 24'-1" Brick FF FC MIN FRONT ELEVATION SCALE 1/=1' LEFT ELEVATION PERSPECTIVE VIEWS 4

5 Roof Framing: 1. Fascia to be 2"x Douglas Fir. 2. For soffit size see details.. For spans and dimensions refer to floor plans. 4. Trusses are to be an approved truss design from the truss manufacture's engineer. Install as per engineers specs 5. Use Simpson H-1 hurricane anchors at each truss or rafter to wall connection. 6. Solid blocking required between joists, rafters, and trusses over all bearing walls. Such blocking shall be 1 ½" minimum thickness and full depth of joists, rafters, or trusses.. Minimum header sizes shall be according to the header size table unless otherwise noted. 8. Basis of design roof live/snow load of psf, and roof dead load of 15 psf. 9. Plywood roof decking to be Min ½" thick, 24/0, CDX or 5/8 wafer. RO FRAMING 8/12 Pitch SEE GENERAL SPECS AND NOTES FOR FRAMING DETAILS PRE-ENGINEERED ENERGY TRUSSES AS SUPPLIED BY TRUSS MANUFACTURER 1. Trusses to be 24" O.C. 2. Attic access min 22 1/2" x 0" were most convenient. For all areas greater than 0".Place vaults where possible as indicated on the floor plan 4. Install all trusses as per truss manufacturer installation guidelines. 5. 8/12 Pitch General framing: (Douglas Fir) 1. Minimum header sizes shall be according to the following table unless otherwise noted. Header sizes (single story construction) 2'-0" to 4'-0" Span 2-2x4's 4' + to 6'-0" Span 2-2x6's 6' + to 8'-0" Span 2-2x8's 8' + to 10'-0" Span 2-2x10's 10' + to 12'-0" Span 2-2x12's 2. Brace all exterior walls and cross-stud partitions at each end of building and at least every 25' of length by one of the following: a. Simpson WB 126 wall bracing with -16d nails at each end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of /8 inch.. Fire stopping: a. Fireblock stud spaces over 10' in height, furred spaces, soffits, drop ceilings, cove ceilings, stair stringers at top and bottom of run, bearing walls and ceiling joist lines, etc. Firestopping shall consist of 2" nominal lumber. b. Firestop openings around vents, pipes, ducts, chimneys, and fireplaces at ceiling and floor levels with approved noncombustible materials. 4. CDX plywood is not approved where exposed to weather, i.e., roof overhangs. 5. Exterior wall framing to be 2"x6" studs at 16" o.c. Interior wall, framing at non-bearing walls to be 2"x4" studs at 24" o.c. and at bearing walls 2"x4" studs at 16" o.c. with double top plate. 6. Shear wall to be / CDX plywood applied horizontally.. All stress grade lumber shall comply with WCLA specs and bear approval stamp on all pieces in place. 8. Framing lumber shall be Douglas Fir construction grade Fb 1450 or better unless otherwise noted. 9. Nailing to be per current U.B.C. unless otherwise noted. 10. All bearing partitions shall have double top plates. 11. Structural glued laminated timbers to be stamped by an approved agency. 12. Use redwood or pressure treated sole plates at all exterior walls. Floor Framing: 1. All floor joist to be Douglas Fir #2 or 16" o.c. unless otherwise noted. 2. For spans and dimensions refer to floor plans.. Use Simpson H 2.5 hurricane anchors at each floor joist to bearing wall connection. 4. Solid blocking between joists over all bearing walls, and midspans such blocking shall be 2" minimum thickness and full depth of joists. 5. Minimum header sizes shall be according to the header size table unless otherwise noted. 6. Basis of design: floor live load of 40 psf, and floor dead load of 15 psf.. Floor decking to be ¾" thick T & G wafer board. 8. Joist hangers to be Simpson U210 or equal unless otherwise noted. 9. Double joists and or double blocking at all interior walls. P O Box 4 Mendon, Utah SCAD 5

6 Electrical Systems: 1. Inspection is required prior to backfill of lines. 2. Provide 20 ft. of No. 4 copper wire as ground electrode in foundation footing.. Bond interior piping system with #8 bare copper. 4. Provide main jumping bond with #4 bare copper. 5. Electrical service is to be 200 amp service, 120/240 volt, 1 phase raintight, underground. 6. Provide separate 20 amp circuits to washer.. Provide 20 amp circuits to family and dining room, and a minimum of two 20 amp circuits to kitchen. 8. Prewire for TV, telephone in kitchen, family room, living room, and in every bedroom. 9. Install ground fault current interrupter on exterior, garage, kitchen, and bathroom convenience outlets. 10. Bottom half of outlet controlled by switch when shown. 0X22 CRAWL WP WH WP D/W 0X22 ATTIC GFCI 11. All outlets in kitchen are to be at +44" excluding those for the refrigerator, range, disposal, and dishwasher. 12. Maximum spacing of outlets shall not exceed 12 ft. along wall line and at any wall over 24" wide in all rooms except kitchen, bath, utility, and garage. 1. Install light in walk-in closet 1 minimum horizontal from any shelf. 14. Provide a ventilation fan capable of producing a change of air every 12 minutes for bath or utility. 15. Provide smoke detector alarm conforming to Section 1210(A) U.B.C. and local building codes in every bedroom and on each floor. 16. CO2 Detector on each floor. 1. Ceiling fan hangers on all bedroom and living room lights. 18. Consult with contractor and homeowner for all final light fixture and light placement and details. GFCI GFCI ELECTRICAL LEGEND SYMBOL 4 WP DM GFI WP DESCRIPTION METER SOCKET PANEL BOX CEILING FAN W/ LIGHT FLUORESCENT LIGHT FIXTURE 110V CEILING LIGHT FIXTURE 110V RECESSED LIGHT FIXTURE 110V EAVE LIGHT FIXTURE 110V CHANDILIER LIGHT FIXTURE 110V WALL LIGHT FIXTURE SINGLE POLE SWITCH THREE WAY SWITCH FOUR WAY SWITCH DIMMER SWITCH OUTDOOR SWITCH 110V DUPLEX RECEPTACLE 110V DUPLEX RECEPTACLE GROUND FAULT INTERUPTED 110V DUPLEX RECEPTACLE W/ WEATHERPRO COVER 110VFLOOR MOUNTED DUPLEX RECEPTACLE 240V RECEPTACLE TELEPHONE JACKS P O Box 4 Mendon, Utah sdscad@pcu.net TV TELEVISION JACKS DOOR BELL PUSH BUTTON T THERMOSTAT SMOKE DETECTOR EXHAUST FAN DC DOOR CHIME F A FIRE ALARM PANEL C COMPUTER POINT MAIN FLOOR ELECTRICAL PLAN SCALE SCAD 6

7 CDX PLYWOOD SHEAR WALL INSTALLED W/ LONG DIMENSION ACROSS STUDS. STAGGER VERTICAL JOINTS PANEL SHEATHING USED AS BRACING W/ LONG DIMENSION PARALLEL TO STUDS LEAVE 1/4" EDGES & 1/ ENDS UNLESS OTHERWISE REC- OMMENDED BY MANUFACTURER 8/12 PITCH ASPHALT SHINGLES ROING MATERIAL 0# ROING PAPER 5/ Min RO DECKING WALL FRAMING ENGINEERED TRUSS SYSTEM AND RAFTERS SIDING MATERIAL VENT PER CODE VENTILATION TYPICAL SHEAR WALL N.T.S. GRADE 2 % MIN. SLOPE VERT. #4 24" O.C. MIN. THICKNESS CONCRETE WALL J-BAR DOWELS TO MATCH VERTICAL REBAR SPACING. EXTENDED 24" MIN. INTO FOUNDATION WALL. WITH 6" MIN. HOOK Provide minimum 1" end distance Equal number of specified nails in each end END LENGTH CUT LENGTH CLEAR SPAN END LENGTH Simpson Strong-Tie MAX. SPACING. BOLTS SHALL BE EMBEDDED " MIN. 4" CONC. SLAB 4" COMPACTED GRAVEL COMPACTED SOIL HORIZONTAL REBAR # O.C. W/FIRST BAR PLACED 4" ABOVE FOOTING & LAST BAR 4" BELOW TOP FOUNDATION WALL. 2- #4 REBAR CONTINUOUS GARAGE WALL SECTION 10d 6" O.C. AT EDGES & SEAMS AND 10d 12" O.C. IN FIELD U.N.O. ON SHEAR WALL SCHEDULE 06A-108 Brace all exterior walls and cross-stud partitions at each end of building and at least every 25' of length by one of the following: a. Simpson WB 126 wall bracing with -16d nails at each end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of /8 inch. Continuous strapping from foundation to rafter for shear walls METAL DRIP EDGE RAIN GUTTERS 2 x 6 SUB FASCIA METAL FASCIA 12" MIN OVERHANG METAL VENTED SFIT VINYL SIDING WALL FINISH TYVEK HOUSE WRAP OR EQUIV /16 MIN WALL SHEATHING 2 x 6 FRAMING 16 O.C. FINISH FLOOR A-0 ANCHOR BOLTS 2 x 6 TREATED SILL PLATE FOAM SILL SEAL 6" MIN TO GRADE HEIGHT WATERPROING TO GRADE FOUNDATION WALL 24" MIN A-615 RE-BAR 24" OC VERT & HOR 4" DRAIN TILE IF NEEDED 9" x 1 CONCRETE FOOTING A-615 RE-BAR GRADE " TOP WINDOW HEIGHT (FROM SUB FLOOR) 9' ROOM HEIGHT (FROM SUB FLOOR TO FRAMING) 9' COMPACTED FILL R8 ATTIC INSULATION PRE-ENGINEERED /12 & 4/12 TRUSSES OR FLOOR JOISTS PER PLAN R19 WALL INSULATION VAPOR BARRIER SHEETROCK WALL FINISH /4 T&G SUB FLOOR 9 1/2: I-JOIST FLOOR JOISTS OR EQUIV R19 JOIST INSULATION 4" CONCRETE OVER 4" GRAVEL FILL ONE STORY WALL SECTION STANDARD PLATFORM FRAMING SLAB FOUNDATION SCALE:NTS Note: Paper size 11 x 1 B - size, scale is as stated if printed on 22 x 4 - D size scale is SCAD P O Box 4 Mendon, Utah sdscad@pcu.net