Project Location Suite Location Scale: None

Size: px
Start display at page:

Download "Project Location Suite Location Scale: None"

Transcription

1 GEERAL OTES. THE GEERAL COTRACTOR SHALL PERFORM ALL REQUIRED WORK, ULESS OTHERWISE OTED. ALL REFERECES TO THE "COTRACTOR" ICLUDE THE GEERAL COTRACTOR AD ITS SUBCOTRACTORS; THEY SHALL BE OE AD THE SAME.. THE COTRACTOR SHALL CHECK AD VERIFY ALL FIELD DIMESIOS AD CODITIOS AS THEY RELATE TO THE DRAWIGS AD SHALL BE RESPOSIBLE FOR SAME. I CASE OF AY DISCREPACY, THE COTRACTOR SHALL OTIFY CATTERALL DESIG OFFICE IMMEDIATELY PRIOR TO PROCEEDIG WITH COSTRUCTIO.. IT IS THE COTRACTOR'S RESPOSIBILITY TO ISURE THAT ISTALLATIO METHODS COFORM TO ALL BUILDIG CODE REQUIREMETS. THE MATERIALS SPECIFIED ARE ITEDED TO MEET CODE REQUIREMETS; AY DISCREPACY BETWEE THE COSTRUCTIO DOCUMETS AD CODE REQUIREMETS SHALL BE BROUGHT TO THE ATTETIO OF CATTERALL DESIG OFFICE IMMEDIATELY, BY THE COTRACTOR, PRIOR TO PROCEEDIG WITH THE SPECIFIED WORK.. ALL PARTITIOS ARE DIMESIOED FIISH TO FIISH, ULESS OTHERWISE OTED. 5. ALL PARTITIOS ARE TO BE CHALKED-LIED FOR APPROVAL BY CATTERALL DESIG OFFICE PRIOR TO THE ERECTIO OF FRAMIG. 6. ALL EXISTIG PARTITIOS, FLOORS, AD CEILIG SHALL BE PATCHED OR REPAIRED AS REQUIRED. ALL REPAIRED SURFACES SHALL BE EQUAL TO EW, ULESS OTHERWISE OTED. THE COTRACTOR SHALL ADVISE CATTERALL DESIG OFFICE OF AY EXISTIG COSTRUCTIO WHICH IS OT LEVEL AD PLUMB (WITHI IDUSTRY STADARD) PRIOR TO THE START OF COSTRUCTIO. 7. ULESS OTHERWISE OTED, DO OT SCALE DRAWIGS; DIMESIOS GOVER. LARGE SCALE DETAILS GOVER OVER SMALL SCALE DETAILS. 8. THE GEERAL COTRACTOR SHALL COORDIATE WITH THE BUILDIG MAAGER SPECIFIC TEAT KEYIG REQUIREMETS FOR ALL LOCKSETS ISTALLED BY THE COTRACTOR. THE COTRACTOR SHALL PROVIDE BUILDIG STADARD KEYWAYS O ALL LOCKIG HARDWARE. 9. THE DRAWIGS AD SPECIFICATIOS ARE COMPLEMETARY; WHAT IS REQUIRED BY OE SHALL BE AS BIDIG AS IF REQUIRED BY ALL. 0. O SUBSTITUTIOS OF SPECIFIED MATERIALS SHALL BE PERMITTED WITHOUT FIRST SUBMITTIG SPECIFICATIOS, SAMPLES, AD COST IMPACT TO CATTERALL DESIG OFFICE FOR REVIEW AD APPROVAL.. THE COTRACTOR SHALL COORDIATE HIS WORK WITH ALL OTHER TRADES O THE PROJECT. AY CHAGES OR DELAYS ARISIG FROM COFLICTS BETWEE TRADES SHALL BE THE RESPOSIBILITY OF THE COTRACTOR AT O ADDITIOAL COST TO THE TEAT/LADLORD.. AT THE TIME OF BID SUBMITTAL, THE COTRACTOR SHALL ADVISE CATTERALL DESIG OFFICE I WRITIG OF AY SPECIFIED MATERIALS OR EQUIPMET WHICH ARE EITHER UAVAILABLE OR WILL CAUSE A DELAY TO THE COSTRUCTIO COMPLETIO SCHEDULE.. THE COTRACTOR SHALL VERIFY REQUIRED LOCATIOS AD ICLUDE I BASE BID ALL RELATED COSTS FOR ALL ECESSARY ACCESS PAELS I PARTITIOS, FLOORS OR CEILIGS. THE COTRACTOR SHALL COORDIATE EXACT LOCATIOS WITH CATTERALL DESIG OFFICE PRIOR TO ISTALLATIO.. THE COTRACTOR SHALL SUPPLY AD ISTALL BLOCKIG AD SUPPORTS I PARTITIOS AD CEILIGS AS REQUIRED FOR ISTALLATIO OF SPECIFIED EQUIPMET, ACCESSORIES, AD CABIETRY. 5. THE COTRACTOR SHALL SUBMIT ALL PERTIET SHOP DRAWIGS FOR REVIEW BY CATTERALL DESIG OFFICE, ALLOWIG ADEQUATE TIME FOR REVIEW AD CORRECTIVE ACTIO, WITHOUT IMPACTIG THE SCHEDULE. 6. THE COTRACTOR SHALL BE RESPOSIBLE FOR SUPPLYIG TEMPORARY UTILITIES (POWER, LIGHTIG, WATER) TO THE JOB SITE FOR USE BY ALL COSTRUCTIO TRADES, ICLUDIG THOSE OT SUBCOTRACTORS TO THE GEERAL COTRACTOR. 7. THE COTRACTOR SHALL SUPPLY AD MAITAI CHEMICAL TOILETS FOR THE USE OF ITS EMPLOYEES AD SUBCOTRACTORS ULESS USE OF THE BUILDIG'S FACILITIES HAS BEE AUTHORIZED BY THE BUILDIG MAAGER. 8. THE COTRACTOR SHALL BE RESPOSIBLE FOR PROTECTIG, CLEAIG AD, IF ECESSARY, RESTORIG TOILET ROOMS, JAITOR CLOSETS, ELECTRICAL/TELEPHOE ROOMS, CORRIDORS,, ELEVATORS, TRUCK DOCK AREA AD AY OTHER AREAS UTILIZED. COTRACTOR SHALL SUBMIT A PLA FOR UTILIZIG AD PROTECTIG THESE AREAS DURIG COSTRUCTIO. 9. ALL COTRACTORS SHALL MAITAI THE PREMISES CLEA AD FREE OF ALL TRASH AD DEBRIS, AD SHALL PROTECT ALL ADJACET WORK FROM DAMAGE, SOILIG, PAIT OVER SPRAY, ETC. ALL FIXTURES, EQUIPMET, GLAZIG, SILLS, FLOORS, WALLS, ETC. SHALL BE LEFT CLEA AD READY FOR OCCUPACY. 0. THE COTRACTOR SHALL UTILIZE OLY THE TRASH DUMPSTER DESIGATED FOR THE TEAT IMPROVEMET COTRACTOR AD SHALL MAITAI THE AREA OF THE TRASH DUMPSTER CLEA AD FREE OF TRASH AD DEBRIS.. WHERE REQUIRED, PROVIDE MIIMUM ADDITIOAL PARTITIO THICKESS OR FURRIG FOR PLUMBIG WALLS.. THE COTRACTOR SHALL PROVIDE AD ISTALL ROUGH PLUMBIG AD FIAL HOOK-UP FOR ALL SPECIFIED FIXTURES AD APPLIACES AD SHALL SUPPLY ALL SUCH FIXTURES AD APPLIACES ULESS OTHERWISE OTED.. I ISTACES WHERE DRAWIGS CALL FOR ALIGMET OF EW COSTRUCTIO WITH EXISTIG SURFACES, COTRACTOR SHALL VERIFY THAT SUCH ALIGMET WILL RESULT I A SQUARE AD STRAIGHT COSTRUCTIO, WITHOUT BEDS OR BOWS. IF A QUESTIO EXISTS, COTRACTOR SHALL COFIRM CODITIOS WITH CATTERALL DESIG OFFICE. MECHAICAL, ELECTRICAL, COMMUICATIOS AD CEILIG OTES E DOOR AD HARDWARE OTES. THE MAXIMUM UDERCUT OF ALL DOORS SHALL OT EXCEED /" ABOVE THE SURFACE OF THE FIISHED FLOOR O THRESHOLD. ALL DOORS SHALL BE UDERCUT O THE JOB SITE AD SPECIFICALLY FOR IDIVIDUAL DOOR OPEIGS AD FLOOR FIISHES. THE COTRACTOR SHALL VERIFY THE FIISHED HEIGHT OF ALL FLOOR FIISHES PRIOR TO UDERCUTTIG THE DOORS.. HARDWARE SPECIFIED FOR ISTALLATIO O DOORS AD FRAMES WHICH REQUIRE A FIRE-RATED LABEL SHALL COMPLY WITH ALL CODE REQUIREMETS COVERIG HARDWARE TYPE AD ISTALLATIO METHODS FOR RATED ASSEMBLIES.. ISTALL DOOR CLOSERS AS SPECIFIED O ALL FIRE-RATED DOORS.. ALL DOORS SCHEDULED TO RECEIVE DOOR CLOSERS SHALL RECEIVE BALL-BEARIG HIGES. 5. EGRESS DOORS SHALL BE READILY OPEABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KOWLEDGE OR EFFORT. PLEASE VERIFY AT ALL EXISTIG DOORS AD PROVIDE AT EW DOORS WITHI THE PROJECT AREA. REF: IBC SECTIO DOOR HADLES, PULLS, LATCHES, LOCKS, AD OTHER OPERATIG DEVICES O DOORS REQUIRED TO BE ACCESSIBLE SHALL OT REQUIRE TIGHT GRASPIG, TIGHT PICHIG OR TWISTIG OF THE WRIST TO OPERATE. PLEASE VERIFY AT EXISTIG DOORS AD PROVIDE AT EW DOORS WITHI THE PROJECT AREA. REF: IBC SECTIO Door and Hardware Symbol: 86 A a 8" mininum clearnace required on swing side of door " mininum clearnace required on push side of door when door is installed with closer Door umber Door Type Hardware Group Symbol indicates existing door to remain SHEET IDEX CS General otes, Legends, Project Data A.0 Demolition Plans, Door Schedule A. Construction Plans CD. Partition Details and Elevations E. Legends and otes E. Power Plan, Lighting Plan E. One-Line and Compliance Sheet M. Mechanical otes, Legend, Details M. Mechanical Details M.0 Mechanical Demolition Plan P. Mechanical Plans P.0 Plumbing otes, Fixture List, Details P. Plumbing Plan SPACE PLAER/DESIGER Catterall Design 677 Willow Broom Trail Littleton, Colorado 805 Tel: Attn: Stephen Catterall ELECTRICAL EGIEER RH Engineers Tel: Attn: Mike Garrent COTRACTOR: TBD PROJECT DIRECTORY OWER REPRESETATIVE Alberta Development Partners 5750 DTC Parkway, Suite 0 Greenwood Village, Colorado 80 Tel: Attn: Keri avarette MECHAICAL EGIEER BA Consultants 0 St. Paul Street, Suite 05 Denver, Colorado 8006 Tel: 0.. Attn: Brad Alm Address: Code: Base building construction: umber of stories: Occupancy: Sprinkler system: Fire District Project consists of the remodel of existing tenant improvements, including electrical and mechanical work. Occupancy: Useable Area: Area/Occupants: Conference Area/Occupants: Total Occupants: PROJECT DATA PROJECT CODE AALYSIS Exits Required: Exits provided: 5 E. Commons Avenue Centennial, CO 80 International Building Code, 05 ational Electrical Code, 0 International Mechanical Code, 05 International Plumbing Code, 05 International Energy Conservation Code, 05 ICC/ASI A7.-00, Accessibility Standards (as referenced in the 009 IBC) Type II-B, sprinklered, meets or exceeds requirements of FPA Five, Building Height 7' Group B, Fully sprinklered Littleton B,805 square feet,55 sf; 6 00sf/occupant 60 sf; 8 5sf/occupant occupants CATTERALL DESIG OFFICE 677 Willow Broom Trail Littleton, Colorado 805 T: E: stephen@catteralldesign.com Project Spec Suite 6 Streets of Southglenn 5 East Commons Avenue Centennial, Colorado. REFER TO EGIEERIG DRAWIGS FOR CIRCUITIG AD EXACT SPECIFICATIOS. MECHAICAL AD ELECTRICAL EGIEERS' DRAWIGS ARE OT ITEDED TO SPECIFY EXACT LOCATIOS OF FIXTURES, OUTLETS OR EQUIPMET; REFER TO CATTERALL DESIG OFFICE DRAWIGS.. THE MECHAICAL AD ELECTRICAL DRAWIGS ARE SUPPLEMETARY TO THE ARCHITECTURAL DRAWIGS. IT SHALL BE THE RESPOSIBILITY OF THE COTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWIGS PRIOR TO SUBMITTAL OF BID AD AGAI BEFORE THE ISTALLATIO OF MECHAICAL AD ELECTRICAL WORK. AY DISCREPACY BETWEE THE ARCHITECTURAL AD THE COSULTAT'S DRAWIGS SHALL BE BROUGHT TO THE ATTETIO OF CATTERALL DESIG OFFICE FOR CLARIFICATIO. WORK ISTALLED I COFLICT WITH THE ARCHITECTURAL DRAWIGS SHALL BE CORRECTED BY THE COTRACTOR AT ITS OW EXPESE AD SHALL OT IMPACT THE SCHEDULE.. ALL ELECTRICAL ITEMS OTED FOR ISTALLATIO I CABIET WORK SHALL BE SUPPLIED, ISTALLED AD COORDIATED BY THE COTRACTOR, ULESS OTED OTHERWISE.. ALL LIGHT SWITCHES SHALL BE CIRCUITED AD ISTALLED TO COMPLY WITH LOCAL CODES AD APPLICABLE STATE EERGY REQUIREMETS. 5. ULESS OTED OTHERWISE, ALL COVERPLATES AD DEVICES SHALL BE BUILDIG STADARD. REFER TO EQUIPMET SPECIFICATIOS FOR O- STADARD RECEPTACLES. 7. ISTALL SWITCHES AD OUTLETS FORWARD TO FACE OF FIISHED WALL, ICLUDIG CABIETRY. 8. SPECIFICATIOS AD ILLUSTRATIOS OF MECHAICAL AD ELECTRICAL DEVICES SPECIFIED BY THE MECHAICAL AD ELECTRICAL EGIEERS SHALL BE SUBMITTED TO CATTERALL DESIG OFFICE FOR APPROVAL PRIOR TO PURCHASE. 9. ALL EXHAUST FAS SHALL BE SILET RUIG AD SHALL HAVE A MIIMUM 8' -0" LOG DUCT BETWEE THE RETUR AIR GRILLE AD THE FA MOTOR. THE DUCT SHALL BE LIED WITH " THICK FIBERGLASS LIER; A EQUIVALET LEGTH OF GLASS FIBER FLEXIBLE DUCT IS ACCEPTABLE. 0. ALL DIFFUSERS, EXHAUST FAS AD OTHER MECHAICAL DEVICES THAT PEETRATE THE CEILIG SHALL BE LOCATED I COORDIATIO WITH THE LIGHTIG LAYOUT.. WHERE IDICATED, CLEA ELECTRICAL POWER IS TO BE DISTIGUISHED BY A GRAY RECEPTACLE. SEPARATE CIRCUITS ARE TO BE DISTIGUISHED BY A ORAGE RECEPTACLE.. ALL SPRIKLER HEADS WITH ACOUSTICAL TILE CEILIGS SHALL BE BUILDIG STADARD SEMI-RECESSED ULESS OTHERWISE OTED. CETERIG I CEILIG TILES IS OT REQUIRED.. ALL SPRIKLER HEADS WITHI DRYWALL CEILIGS AD SOFFITS SHALL BE COCEALED HEADS PAITED TO MATCH CEILIG COLOR. Issue/Revisions 6. ULESS OTED OTHERWISE, ALL STADARD COVERPLATES, SWITCHES AD DEVICE FIISHES SHALL BE WHITE. SUBMIT SAMPLES TO CATTERALL DESIG OFFICE FOR APPROVAL. 7. ALL WALL MOUTED POWER AD COMMUICATIOS OUTLETS SHALL BE ISTALLED VERTICALLY AT 8" A.F.F. ULESS OTED OTHERWISE. REFER TO ELECTRICAL LEGED FOR SYMBOLS THAT IDETIFY SPECIAL MOUTIG HEIGHTS. OUTLETS ISTALLED ABOVE 8" SHALL BE ISTALLED HORIZOTALLY. 8. ALL WALL AD FLOOR MOUTED COMMUICATIOS OUTLETS SHALL RECEIVE PULL WIRES ISTALLED BY THE COTRACTOR. 9. ALL LIGHT FIXTURES SHALL BE LOCATED EXACTLY AS SHOW O THE PLAS. COTRACTOR SHALL OBTAI APPROVAL FROM CATTERALL DESIG OFFICE OF LAYOUT OF LIGHT FIXTURES PRIOR TO FIAL COECTIOS AD SECURIG OF FIXTURES. 0. SWITCHES SHALL BE ISTALLED AT " A.F.F. TO CETER AD LOCATED WITHI 8" OF DOOR JAMBS OR SIDELITES.. ALL WORK SHALL COFORM TO THE LATEST RULES AD REGULATIOS OF THE ATIOAL ELECTRICAL CODE (.E.C.), TITLE 8 DIVISIO OF IDUSTRIAL SAFETY, PERTIET.F.P.A. PUBLICATIOS, AD OTHER FEDERAL, STATE AD CITY AGECIES HAVIG JURISDICTIO. 5. ALL FIRE RATIGS OF EXISTIG AD EW COSTRUCTIO SHALL BE MAITAIED. ALL PEETRATIOS THROUGH FIRE RATED WALLS OR FLOORS SHALL BE PROVIDED WITH CODUIT SLEEVES AD A RE- ETERABLE FIRE/SMOKE BARRIER MATERIAL TO MEET OR EXCEED THE RATIG OF THE COSTRUCTIO. ALL EXISTIG FIRE STOPPIG WHICH IS REMOVED SHALL BE REPLACED. 6. ALL CABLES SHALL BE LISTED AD CLEARLY IDETIFIED FOR ISTALLATIO WITHOUT CODUIT I CEILIG PLEUMS AD I RISERS. 7. ALL WIRIG SHALL BE SUPPORTED IDEPEDETLY OF THE CEILIG SYSTEM. ELECTRICAL AD MECHAICAL SUPPORTS. CABLES SHALL BE ADEQUATELY SUPPORTED WITH SUPPORTS DESIGED FOR TYPE OF CABLE. ALL WIRIG SHALL, I GEERAL, BE COCEALED AD SHALL FOLLOW THE BUILDIG LIES. T. ALL SWITCHES SHALL BE GAG PLATED, WHERE APPLICABLE.. ALL WALL MOUTED COMMUICATIOS OUTLETS SHALL HAVE A JUCTIO BOX. THE COTRACTOR SHALL PROVIDE COVERPLATES AT ALL ELECTRICAL OUTLETS.. WHERE WALL MOUTED OUTLETS ARE IDICATED SIDE BY SIDE, THE MAXIMUM SEPARATIO BETWEE SUCH OUTLETS SHALL BE 6" CETER - TO-CETER, ULESS OTED OTHERWISE.. ALL WALL MOUTED POWER AD COMMUICATIOS OUTLETS SHALL BE ISTALLED EXACTLY AS DIMESIOED OR OTED. IF O DIMESIOS ARE OTED, THE COTRACTOR SHALL SCALE LOCATIOS FROM THE DRAWIGS AD ISTALL ACCORDIGLY. AY DISCREPACIES BETWEE OTED DIMESIOS AD FIELD CODITIOS SHALL BE REPORTED TO CATTERALL DESIG OFFICE IMMEDIATELY, PRIOR TO ISTALLATIO. 5. DO OT ISTALL OUTLETS EITHER BACK-TO-BACK OR SIDE-BY-SIDE O OPPOSITE SIDES OF THE SAME WALL EXCEPT WHERE SPECIFICALLY DIMESIOED. SEPARATE ALL SUCH OUTLETS WITH OE STUD (VERTICALLY OR HORIZOTALLY). 8. ALL WIRIG RUS LOCATED ADJACET TO ELECTRICAL POWER FEEDER RUS SHALL MAITAI A MIIMUM SEPARATIO OF " FROM CODUITS AD " FROM BUS DUCTS. 9. ALL COECTORS, SPLITTERS, TAPS, AD SPLICES ISTALLED ABOVE THE CEILIG SHALL BE LOCATED I ACCESSIBLE CEILIG AREAS. PROVIDE ACCESS PAELS WHERE REQUIRED FOR ISTALLATIO I O- ACCESSIBLE AREAS. 0. OUTLETS SHALL COSIST OF A X X / DEEP BACK BOX WITH A SIGLE-GAG (0R -GAG, AS REQUIRED) TRIM RIG AD A CODUIT STUBBED UP TO THE EAREST ACCESSIBLE CEILIG AREA. ALL CODUIT SHALL BE EITHER ELECTRICAL METALLIC TUBIG (EMT), RIGID STEEL CODUIT (WHERE REQUIRED BY CODE) OR FLEXIBLE ALUMIUM CODUIT ISTALLED I ACCORDACE WITH LOCAL CODES.. COVER PLATES SHALL MATCH THE COLOR OF THE COVER PLATES FOR THE DEVICES I THE ROOM AD SHALL ICLUDE A COECTOR. (THE BUILDIG STADARD COLOR FOR COVER PLATES I TYPICAL AREAS IS WHITE.) FEED-THROUGH CABLE GROMMETS WITH EXCESS CABLE COILED ISIDE OR OUTSIDE THE WALL IS OT ACCEPTABLE. Project Location Suite Location Scale: one General otes Project Data Project umber: ALL ELECTRICAL OUTLETS SPECIFIED FOR USE BY COMPUTER EQUIPMET SHALL UTILIZE THE SAME CLEA CIRCUITS. O OTHER ELECTRICAL OUTLETS SHALL UTILIZE THESE CIRCUITS. REFER TO ELECTRICAL EGIEER'S DRAWIGS.. ALL BOXES, COVERS AD DEVICES SHALL BE SET TRUE AD SQUARE I THE WALL AD SHALL, I GEERAL, BE LOCATED ADJACET TO THE POWER AD COMMUICATIOS OUTLETS, EQUALLY SPACED FROM EACH OTHER AD MOUTED THE SAME HEIGHT (+8" ABOVE THE FIISHED FLOOR).. ALL CABLES WHICH ETER OR EXIT A TEAT SUITE SHALL BE CLEARLY AD PERMAETLY TAGGED AT BOTH EDS AD AT POITS OF ETRY AD EXIT OF EACH TEAT SUITE, TO IDETIFY "TELEPHOE"/"C.A.T.V."/ETC., TEAT SUITE UMBER AD ROOM UMBER OF OUTLET LOCATIO. Date: 9 ovember 08 Project Manager: Stephen Catterall CS All dimensions and conditions must be checked and verified onsite by the contractor and subcontractors. The Project Manager shall be notified of any discrepancies prior to proceeding with the work. Copyright Catterall Design, Inc. All rights reserved.

2 Ramp down /+" DW Galley 06 /+" Ref DF Restroom 07 /GFI Janitor 08 Ramp down Soffit for ceiling height transition; 0'-" to underside. E DW /CD. Galley 06 '-" DF 7'-0" Restroom 07 5'-0" 5 6 '-" Janitor 08 7'-" Portion of slab is open. Complete concrete after plumbing work. CATTERALL DESIG OFFICE 677 Willow Broom Trail Littleton, Colorado 805 T: E: stephen@catteralldesign.com '-0" UP Open Area 0 0 Partition Plan Key otes UP Furr wall to create consistant plane to underside of ceiling. 0 0'-0" Reception 00 0 Conference 0 Provide (8.75) lineal feet of upper and lower plastic laminate cabinets, single s.s. sink, disposal, faucets, dishwasher, and hot water connection. Locate hot water heater in plenum. Provide drinking fountains. Provide janitor sink. Provide clear, tempered glass partition in wrapped opening, with top & bottom u-channels (clear alum). Height to align with top off door frame (approx. 9'-.5"). Open Area 0 Complete gyp. board installation (typical at perimeter of suite) Reception 00 0 Conference 0 0'-0" 6'-9" Power & Communications Plan Scale: /8" = ' - 0" Hardware otes. Lever hardware, where used: Manufacuture: Corbin Russwin Style: Mortise, ML 000 Series Lever: TBD Finish: 66/US6D Door Opening Schedule Partition Plan Scale: /8" = ' - 0" Align Relocate existing storefront door section and storefront glazing. Install new panic hardware and closer. Project Spec Suite 6 Streets of Southglenn 5 East Commons Avenue Centennial, Colorado Issue/Revisions # ominal SizeDescription Frame Frame Finish Fire Rating Hardware Comments - '-0" x 9'-0" Solid core door Aluminum Satin /A Latchset P/L finish: Formica, Aged Ash, Woodbrush Finish, 88-WR 5 '-0" x 9'-0" Solid core door Aluminum Satin /A Restroom lock P/L finish: Formica, Aged Ash, Woodbrush Finish, 88-WR 6 '-0" x 9'-0" Solid core door Aluminum Satin /A Stotage lock P/L finish: Formica, Aged Ash, Woodbrush Finish, 88-WR Ramp down Clg. ht: '-0" Clg. ht: 9'-0" Ceiling and Lighting otes Finish Specifications Ramp down Clg. ht: 9'-0". Install ' x ' t-bar ceiling grid with Armstrong nd Look tiles. Luminaire Schedule P For flooring, contact Vaughn Loudner, C Interiors vaughn@cinteriors.com Paint, installed throughout U..O.; eggshell finish Manufacturer: Benjamin Moore Color: TBD LVT DW Galley 06 DF Restroom 07 Janitor 08 Concrete floor to remain Clg. ht: 9'-0" Fluxwerx TR-/-B-5-D-M PT Porcelain wall tile, install at all restroom walls to +8". Manufacturer: DalTile Style: atural Hues, Ceramic Wall Tile Size: " x 9" field tile; with Surface Bullnose Runners and Corners Color: tbd Grout: 05 UP Clg. ht: 9'-0" PT Porcelain floor tile, " x " Manufacturer: Style: Color: Grout: UP Open Area 0 0 Clg. ht: '-0" Clg. ht: 9'-0" Clg. ht: 9'-0" C LVT Carpet tile, " x " Manufacturer: Milliken Collection: Southern Analog Style: Pinhole Color: Diffuse Installation: Monolithic LVT, installed where noted; Size: 9" x 8" Manufacturer: Milliken Style: Abstract/Stone/Wood Color: tbd Installation: 50/50 offset Reception 00 0 Conference 0 Construction Plans Project umber: 67 Date: 9 ovember 08 B Rubber base, " coved Manufacturer: Johnsonite Color: tbd Project Manager: Stephen Catterall A. Reflected Ceiling Plan Scale: /8" = ' - 0" Finish Plan Scale: /8" = ' - 0" All dimensions and conditions must be checked and verified onsite by the contractor and subcontractors. The Project Manager shall be notified of any discrepancies prior to proceeding with the work. Copyright Catterall Design, Inc. All rights reserved.

3 CATTERALL DESIG OFFICE 677 Willow Broom Trail Littleton, Colorado 805 T: E: /" metal stud bracing to deck 8'-0" o.c. minimum, at door frames, and at changes of partition direction Brace to structure Lay-in acoustic insulation installed above the ceiling, to extend '-0" each side of partition /" metal stud bracing to deck 8'-0" o.c. minimum, at door frames, and at changes of partition direction Suspended 0'-0" Suspended '-0" Suspended 9'-0" () layer 5/8" thick gyp. board from floor slab to underside of supended ceiling Align with top of door frame Clear, tempered /" thick glass in top and bottom u-channels (satin alum.) Suspended 0'-0" Friction fit fiberglas insulation, full height of partition: Owens/Corning fiberglas noise barrier batts, OCF friction fit building insulation or approved equal; fiberglas thickness to equal stud depth. () layer 5/8" thick gyp. board from floor slab to " above supended ceiling /" x 5 ga. metal " o.c. from floor slab to underside of supended ceiling /" x 5 ga. metal " o.c. from floor slab to " above supended ceiling Metal runner to be ammo shot to " o.c. Concrete slab OTES. All gypsum board sheets are to run vertically.. o gypsum board joints except at studs. Concrete slab Metal runner to be ammo shot to " o.c. Concrete slab OTES. All gypsum board sheets are to run vertically.. o gypsum board joints except at studs. Project Spec Suite 6 PARTITIO DETAIL Scale: one PARTITIO DETAIL Scale: one PARTITIO DETAIL Scale: one Streets of Southglenn 5 East Commons Avenue Centennial, Colorado Issue/Revisions '-0" '-8" '-6" Dishwasher '-0" Plastic laminate upper and lower cabinets. Solid surface countertop and " back splash. ELEVATIO: BREAKROOM CABIETS Scale: /" = '0" Partition Details Elevations Project umber: 67 Date: 9 ovember 08 Project Manager: Stephen Catterall CD. All dimensions and conditions must be checked and verified onsite by the contractor and subcontractors. The Project Manager shall be notified of any discrepancies prior to proceeding with the work. Copyright Catterall Design, Inc. All rights reserved.

4

5

6

7

8

9

10

11

12