1 Appendix 3 Certified Passivhaus DETAILS

2 braced mm ventilated timber facade or 0,039 W/(mK) - Steico Flex EWEC 01 Wall External Corner, Wand Aussenecke

3 or ventilated timber facade mm braced panel 0,039 W/(mK) - Steico Flex EWIC 01 External Wall Internal Corner, Wand Innenecke

4 / reed STEICOflex 60mm timber 60x120 plasterboard x / according to STEICOflex timber 60x120 ventilated timber facade / vapour permeable certified render system w<0,1kg/m 2 *h 0,039 W/(mK) - Steico Flex EWIW 01 Junction Internal wall - External wall, Innenwandeinbindung

5 RENDER WOOD FACADE STEICOflex 0,039 W/(mK) board floor STEICOfloor 40 STEICOtherm 20 Lignotrend Rippe/Decke flooring concrete screed mineral insulation Lignotrend Rippe/Decke 200 STEICOsoundstrip ,039 W/(mK) - Steico Flex ventilated timber facade / vapour permeable certified render system w<0,1kg/m 2 *h EWCE 01 Wall-Ceiling (CLT), Wand Deckeneinbindung (KLH)

6 25 60 roof tiles roofing battens and counter battens breather membrane STEICOuniversal STEICOjoist / STEICO ZELL 0,044 W/(mK) wooden batten airtightness membrane with variable value Sd = 0,2-10 m plaster board timber ceiling Airtight membrane with variable value Sd = 0,2-10 m WOOD FACADE wooden batten suspended ceiling system (service installation zone) plasterboard RENDER timber 95x ventilated timber facade / vapour permeable certified render system w<0,1kg/m 2 *h ROEA 01 Roof Eaves (I-beam), Dach Traufe (I-Träger)

7 Airtight membrane with variable value Sd = 0,2-10 m RENDER WOOD FACADE Roof tiles counter battons roof battons roof membrane OSB/Plywood/Wooden boards 22 mm STEICOjoist with STEICO ZELL 0,044 W/(mK) airtight membrane with variable value Sd = 0,2-10 m wooden batton plaster board timber ceiling wooden batten suspended ceiling system (service installation zone) plasterboard ventilated timber facade / certified render system (vapour permeable) ROVE 01 Roof Verge (I-beam), Dach Ortgang (I-Träger)

8 roof tiles roofing battens and counter battens breather membrane STEICOuniversal STEICOjoist / STEICO ZELL - 0,044 W/(mK) wooden batten airtightness membrane with variable value Sd = 0,2-10 m plaster board timber ceiling Airtight membrane with variable value Sd = 0,2-10 m RORI 01 Roof Ridge (I-beams), Dach First (I-Träger)

9 80 DETAIL FS-EW (2) Simplified foundation on XPS vapour permeable certified render system w<0,1kg/m2*h airtight tape STEICOunderfloor 5 mm bitumen Taped to concrete floor slab flooring reinforced concrete slab PE sheet +-0,00 XPS sand blinding rendered insulated plinth concrete blocks ,02 0-0,380-0, drainage pipe coated in geotextile concrete strip foundation 0,037 W/(mK) - XPS (Extruded Polystyrene) nonfreezing depth FSEW 01 Floorslab-Wall, Bodenplatte-Wand

10 Airtight tape between window frame and purenit and purenit and concrete floor slab Purenit -0,020 flooring concrete screed w/ optional underfloor heating mineral insulation reinforced concrete slab PE sheet +-0,00 XPS sand blinding -0, dense concrete blocks 0,037 W/(mK) - XPS (Extruded Polystyrene) perforated drainage pipe enclosed in geotextile concrete strip foundation nonfreezing depth 0,086 W/(mK) - Purenit 500 M WITH 01 Threshold, Schwelle

11 80 Concrete floor slab / reed STEICOflex 60mm timber 60x120 plasterboard flooring reinforced concrete slab PE sheet XPS sand blinding +-0,00 timber 60x120-0,180-0,020-0,380 0,037 W/(mK) - XPS (Extruded Polystyrene) FSIW 01 Floor slab - Interior Wall, Bodenplatte - Innenwand

12 Airtight tape beteen frame and membrane 0,055 W/(mK) - Agepan THD Static 40mm WIBO 01, WITO 01, WISI 01 Smartwin Solar - Wall connection 01

13 Airtight tape beteen frame and membrane 0,055 W/(mK) - Agepan THD Static 40mm WIBO 02, WITO 02, WISI 02 Smartwin Solar - Wall connection 02

14 Airtight tape beteen frame and membrane 0,055 W/(mK) - Agepan THD Static 40mm WIBO 03, WITO 03, WISI 03 Smartwin Solar - Wall connection 03