1 Product Data Sheet Product Data Sheet Edition Urethane Wood Flooring Adhesive Description Features Urethane Wood Flooring Adhesive is a low solvent, low V.O.C, one component, moisture curing polyurethane adhesive. This product is designed for easy trowel-on application over concrete or wood substrates to install materials such as solid hardwood planks, engineered flooring and some parquet flooring. Product has superior non-slump capability. This gives it excellent shrink resistance and allows it to provide consistent contact between the wood flooring and the substrate, during and after installation. Low Solvent / Low V.O.C / Low Odor Minimal shrinking and non-slump for superior contact Trowels easily, yet offers good wet, green grab High bond strength. Superior elasticity gives quiet, more cushioned walking over installed flooring. Application variety: flooring may be applied using the wet lay or walk-on method. Surface Preparation Surfaces should be dry, free of dirt, loose particles, paint overspray, oil, wax, grease or any other substance, which may affect adhesion. The floor level must not vary beyond 3/16 th of an inch per 10 feet. If some materials prove hard to remove during preparation, surface abrasion such as sandblasting or some similar method is recommended. A Calcium Chloride test must be performed. (Using an anhydrous calcium chloride test kit according to ASTM F-1869 test method), and up to 82% RH (tested in accordance with ASTM F-2170). Products Limitations and Directives This adhesive is not a moisture barrier by itself. Do not use on wet, frozen, friable or contaminated surfaces. Do not add water to this adhesive in the pail. Do not mix this adhesive. Warnings KEEP OUT OF REACH OF CHILDREN - PRODUCT INTENDED FOR PROFESSIONSL USE - STORE IN A TIGHTLY SEALED CONTAINER - AVOID DIRECT SKIN CONTACT - NOT FOR HUMAN CONSUMPTION - CONSULT MATERIAL SAFETY DATA SHEET PRIOR TO USING THIS PRODUCT - SMALL Children can fall into bucket and drown. Keep children away from bucket with even a small amount of fluid. 1

2 Product Data Sheet Product Data Sheet Edition Urethane Wood Flooring Adhesive Physical and Chemical Data V.O.C. Level <30.00 g/l., Flash Point >250 F, Odor Very low due to very low V.O.C. content., Freeze/Thaw, Stability Stable. Color Tan, Tack Onset Approx. 60 min. at 70F, 45% relative humidity. Cure Time Under ambient conditions of around 70F and 45% relative humidity, the adhesive should set to allow light foot traffic after 4 hours. Normal traffic can resume after 12 hours. Higher humidity and temperature will accelerate set speed., Shelf Life Lasts 12 months in unopened container (store under ambient conditions in a dry area) Installation Safety Data Pour product over the correctly prepared surface, then trowel product using a suitable trowel (it is recommended that rubber gloves are used when skin contact may occur). Install flooring using the application method of your choice. During application of the wood floor, any adhesive, which gets onto the flooring should be cleaned off with a dry cloth. For better results use a urethane remover. Mineral spirits may be used for cleaning if necessary (not recommended). Tools should be cleaned before the glue sets, using a dry cloth and mineral spirits. May contain calcium carbonate (CAS ), MDI methylenediphenylenediisocyanate (CAS ). Contains no California Proposition 65 listed chemicals. Limited Warranty Parkay Floors warrants this product to be in accordance with its technical properties as outlined on its data sheet for a period not exceeding 12 months following the date of installation, providing the Parkay Floors product has been stored in accordance with its data sheet, used within the duration of its shelf life and applied in full compliance with its data sheet. No warranty on bamboo flooring products. The user of this product determines its suitability for any intended use and assumes all associated risks thereof. In the event of a warranty claim, Parkay Floors shall pay for reasonable material for a one time replacement of the area which is defective as a result of the adhesive as deemed by Parkay Floors. Sole remedy for buyer shall be limited to the replacement price of the aforementioned material exclusive of labor or cost of labor. No warranty other than the aforementioned is expressed or implied regarding this product, including any warranty for the sale of this product for a particular application. Parkay Floors assumes no responsibility for personal injury or property damage to sellers, users or third parties caused by this material. Such sellers or users assume all risks associated with this material. A Calcium Chloride test must be performed otherwise warranty is voided. THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY, AND LOCBOND DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR 2

3 Product Data Sheet IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. It is the sole responsibility of the buyer to determine the suitability of the product for use with a particular flooring product or for a particular type of installation, and any recommendation by LocBond regarding use of the product is not intended to be a warranty that the product is suitable for a particular application. It is the buyer s obligation to test the suitability of the product for an intended use prior to using it. This Warranty gives you specific legal rights, and you may also have other rights that vary from state to state. This Warranty replaces and supersedes all prior warranties that may appear to apply to the product you have purchased. Exclusions: This Warranty does not cover damage resulting from: Structural failure, faulty structural design, structural movement, excessive structural deflection or other failure of substrate, inadequate subflooring, or improper preparation of substrate or subfloor Excessive substrate moisture; moisture due to improper preparation of substrate; exposure to excessive levels of atmospheric moisture or humidity; or exposure to water from flooding, leaks, puddling, hydrostatic head, or any source of moisture that does not originate from the sub-floor. Exposure to excessively low or high temperatures or humidity Natural disasters, including but not limited to earthquakes, fires, floods, or hurricanes; accidents; or other unexpected circumstances Normal wear and tear Misuse; improper alteration, modification, or dilution of product; exposure to corrosive materials or contaminants; industrial applications subject to chemical or mechanical abuse; improper maintenance or use of cleaning products; failure to use product within its shelf life; or any other failure to install and maintain floor in accordance with (i) LocBond s most recent Technical Data Sheet and any other instructions, guidelines and data published by LocBond regarding the product, (ii) the flooring manufacturer s instructions, guidelines and data, (iii) applicable building codes, and (iv) standard industry guidelines and practices. Remedy for Breach of Warranty: In the event of a valid claim under this Limited Warranty, as buyer s sole remedy, LocBond shall pay the reasonable cost of materials, on a square foot basis, necessary to repair or replace the portion of the original installation that is proven to be defective. IN NO CASE WILL LOCBOND BE LIABLE FOR DIRECT, INCIDENTAL, CONSEQUENTIAL, SPECIAL, ECONOMIC, OR OTHER DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you. Making a Claim: This Warranty is to the original purchaser and is not transferable or assignable. Any claims must be made within 30 days of discovery of an alleged failure to conform to specifications or an alleged manufacturing defect. Written proof of purchase must be submitted with the notice of claim. LocBond must be provided an opportunity to inspect the floor, and to take samples of materials used in the floor installation, prior to any repair or replacement work. IF ANY REPAIR OR REPLACEMENT WORK IS DONE BEFORE LOCBOND IS GIVEN AN OPPORTUNITY TO INSPECT THE FLOOR AND TAKE SAMPLES, THIS WARRANTY WILL BE VOID. 3

4 Product Data Sheet Product Data Sheet Edition Urethane Wood Flooring Adhesive Trowel Recommendations Trowel Dimensions Floor Type Coverage 3/16 x ¼ x ½ V Notch Multiply engineered/laminated plank 6 wide or less and 5/8 thick or less.solid flooring 3 wide or less and ½ thick or less. ~55 sq. ft. per gallon ¼ x ¼ x ¼ Square Notch Multiply engineered/laminated plank greater than 6 wide and less than 5/8 thick.solid flooring greater than 3 wide and ½ thick or less.¾ shorts and parquet. ~35 sq. ft. per gallon 1/8 x 1/8 x 1/8 Square Notch Finger block parquet less than ½ thick ~80 sq. ft. per gallon Installation Pour product over the correctly prepared surface, then trowel product using a suitable trowel (it is recommended that rubber gloves are used when skin contact may occur). Install flooring using the application method of your choice. During application of the wood floor, any adhesive, which gets onto the flooring should be cleaned off with a dry cloth. Mineral spirits may be used for cleaning if necessary as long as flooring manufacturer allows it. Tools should be cleaned before the glue sets, using a dry cloth and mineral spirits. 4

5 MSDS Material Safety Data Sheet and Locbond Professional 2000 Date: July, 2014 Section 1 General Information Product Description: Single Component Urethane Wood Adhesives Product Name: LocBond 500 and LocBond 2000 Company Name: Parkay Floors Contact Number: (954) Section 2 Composition and Ingredients Component CAS Number Weight Percent OSHA (PEL) ACGIH (TLV-TWA) Diphenlymethane <1% ppm diisocyanate Calcium Carbonate % - 60% 15 mg/m3 10 mg/m3 Section 3 Hazard Identification Product reacts with water to release small amounts of carbon dioxide. Product is a skin and eye irritant. Product contains small amounts of MDI isocyanate and small amounts of mineral spirits. KEEP OUT OF THE REACH OF CHILDREN. Vapors are minimal at room temperature. Respiratory sensitization can occur due to residual MDI content. Section 4 Emergency and First Aid Procedures Eyes: Skin: Inhalation: Ingestion: Flush with large amounts of cool water for at least 15 minutes while holding eyelid open. Seek medical attention. Remove contaminated clothing. Wash area of contamination with soap and water. If rash or irritation or other symptoms persist, seek medical attention. Remove to fresh air. If breathing has stopped initiate artificial respiration and obtain immediate medical attention. Do not induce vomiting. Do not give anything by mouth. Seek immediate medical attention. Section 5 Fire Fighting Measures Flash Point: >200 F Lower Explosive Limit: N/A Upper Explosive Limit: N/A Extinguishing Media: 5

6 Dry chemical, foams or water spray, carbon dioxide. Fire Fighting Procedures: Use self contained breathing apparatus and protective clothing. Fire and Explosion Products: Combustion of this product may yield irritating or toxic gases. HMIS (Hazard Materials Identification System) Rating: Health 1 Fire 1 Reactivity 0 Protection - B Carcinogenicity: OSHA NO / NTP NO / IARC NO Likely Route of Entry into Body: Skin contact. Contact: May cause irritation to skin on direct contact which may result in a rash or reddening. May also cause skin sensitization and / or dermatitis. Ingestion: May cause irritation, discomfort and vomiting. Do not induce vomiting. Seek immediate medical attention. Inhalation: Risk of inhalation hazard is minimal. If it is perceived that inhalation may be causing irritation, remove to fresh air. If any form of irritation, dizziness or other effect persists, seek medical attention. Medical Conditions which May be Aggravated by Overexposure: Preexisting skin and respiratory conditions. Previously sensitized individuals may have allergic reactions. Section 6 Accidental Release Measures Spill or Leak Clean Up Procedures: While utilizing correct protective equipment, place spilled material into an appropriate container. Waste Disposal: Dispose of material in accordance with local, state and federal regulations. Section 7 - Handling and Storage: Store this product in a cool dry area, out of direct sunlight. Store in a well ventilated area away from all sources of ignition. Avoid contact with skin and eyes. Section 8 Exposure Controls and Personal Protection Ventilation: Use in well ventilated areas only to maintain PEL / TLV levels below set exposure limits. Respiratory Protection: Due to the low V.O.C. nature of this product, respiratory protection is not normally required. However, if PEL / TLV levels may potentially be exceeded, use NIOSH / MSHA approved respirator. 6

7 Eye Protection: Wear safety glasses or goggles as necessary to protect eyes. Skin Contact: Protective gloves are recommended in situations when direct skin contact is unavoidable (nitrile, rubber or better). Other Protective Equipment: Use other types of equipment as needed to help minimize contact. Section 9 Physical and Chemical Properties Appearance and Odor: Tan / creamy liquid / low odor Solubility in Water: Insoluble Evaporation Rate (Compared to Butyl Acetate as 1.0): <1.0 Boiling Point: >300F ph: N/A Vapor Density (Air = 1.0): >1.0 Volatile Organic Content: <100.0 g/l Vapor Pressure: <1 mm 75F / 24C Freezing Point: N/E Section 10 Stability and Reactivity Stability: Conditions to Avoid: Materials to Avoid Contact with: Stable. Exposure to water will cure material. Long term exposure to elevated temperatures will increase viscosity of material. Alcohols, acids, amines, water. Hazardous Decomposition products: Oxides of nitrogen and carbon, hydrocarbons, hydrogen cyanide. Section 11 Toxicological Information Detrimental health effects are not expected as long as correct industrial hygiene and safety protocols are followed. Section 12 Ecological Information This formulation has not been tested for environmental impacts. Section 13 Disposal Considerations Dispose of material in accordance with local, state and federal regulations. 7

8 Section 14 Transportation Information DOT: UN: Not regulated as a hazardous material. Not regulated as a hazardous material. Section 15 Regulatory Information Contains CAS Number Percent Diphenylmethane diisocyanate <1% TSCA: All components in this product are listed except where written as exempt. Pennsylvania: Hazardous component at 1% or greater: Mineral spirits. Non-hazardous at 3% or greater: reacted urethane prepolymer. New Jersey: Reacted urethane prepolymer, mineral spirits (CAS ), Diphenylmethane diisocyanate (CAS ). Section 16 Disclaimer All information set forth herein is believed to be accurate. However, no warranty is expressed or implied regarding the accuracy or completeness of this information. Parkay Floors assumes no responsibility for personal injury or property damage to sellers, users or third parties caused by this material. Such sellers or users assume all risks associated with this material. 8